Loading...
2301 MAYPORT RD ELPP18-0034 ELECT RUN CONDUIT PERMAUGMENT ID - SPRINT SITE CASCADE SPRINT SITE NAME - TOWER TYPE: LANDLORD SITE ID: SITE INFORMATION SPRINT SITE CASCADE: SPRINT SITE NAME: LANDLORD SITE ID: SITE ADDRESS: COUNTY: MAP/PARCEL #: LATITUDE: LONGITUDE: LAT/LONG TYPE: GROUND ELEVATION: CURRENT ZONING: JURISDICTION: OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION: A.D.A. COMPLIANCE: PROPERTY OWNER: TOWER OWNER: CARRIER/APPLICANT: ELECTRIC PROVIDER: FIBER PROVIDER: JA73XCO54 ATLANTIC BEACH TBD JA73XC054F17.I1 JA73XCO54 ATLANTIC BEACH WATER TOWEF, TBD 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 DUVAL 1693980070 30° 20'59.802" N (30.349525°) 81 ° 24' 48.67" W (-81.41171666°) NAD83 42.651 ±FT. OR CITY OF ATLANTIC BEACH U VB FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 SPRINT 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251-2650 FLORIDA POWER & LIGHT (800)226-3545 UNITI (727)471-5600 PROJECT TEAM SAC CONTACTS: SAC WIRELESS 540 W. MADISON ST., 17TH FLOOR CHICAGO, IL 60661 SPRINT CONTACTS: TBD TBD@SPRINT.COM A&E FIRM: GPD GROUP,INC. 520 SOUTH MAIN STREET, SUITE 2531 AKRON, OHIO 44311 JUSTIN BUTTERFIELD (330) 572-2100 THE PARTIES ABOVE HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENTAND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. Sprint')� SPRINT DARK FIBER DRAWING INDEX SHEET# SHEET DESCRIPTION T-1 TITLE SHEET AAV -1 DARK FIBER SITE PLANS AAV -2 DARK FIBER EQUIPMENT DETAILS AAV -3 SITE PHOTOS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. I PROJECT DESCRIPTION I SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY. SPRINT: 1. INSTALL ±10' OF NEW 2" CONDUIT FROM PROPOSED MMP IN ROW TO Y -INTERCEPT INTO EXISTING 2" CONDUIT FROM EXISTING MMP. 2. INSTALL HH AT Y -INTERCEPT POINT, FIELD SERVICES: 1. INSTALL 125' NEW FIBER IN EXISTING 2" CONDUIT FROM TELCO/PPC CABINET TO MMBTS. 2. REMOVE LEGACY COPPER EQUIPMENT FROM TELCO/PPC CABINET. DFV: 1. INSTALL ±630' OF NEW FIBER IN EXISTING 2" CONDUIT FROM HOFFMAN BOX ON H -FRAME TO THE MMP. 2. INSTALL NEW MMP HH. SITE ADDRESS COUNTY: JURISDICTION 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 DUVAL CITY OF ATLANTIC BEACH LOCATION MAP u4 1 � SRE �* I - NO SCALE': DRIVING DIRECTIONS FROM JACKSONVILLE EXECUTIVE AT CRAIG AIRPORT (CRG): HEAD NORTH ON AVIATION AVENUE. TURN LEFT ONTO ST. JOHNS BLUFF ROAD NORTH. USE THE LEFT TWO LANES TO TURN LEFT ONTO ATLANTIC BOULEVARD. USE THE RIGHT LANE TO TAKE THE MAYPORT ROAD RAMP TO NAVAL STATION MAYPORT. MERGE ONTO MAYPORT ROAD. YOUR DESTINATION WILL BE ON THE RIGHT IN 11.5 MILES. APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK AND MATERIALS SHALL BE PERFOMRED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. BUILDING/DWELLING CODE 2017 FLORIDA BUILDING CODE (2015 IBC) LEONARDO A. SFERRA STRUCTURAL CODE TIA-222 - G ADDENDUM NO. 2 - MECHANICAL CODE 2017 FLORIDA BUILDING CODE (2015 IMC) LICENSE NO. 80859 PLUMBING CODE 2017 FLORIDA BUILDING CODE (2015 IPC) ELECTRICAL CODE 2014 NATIONAL ELECTRICAL CODE (NEC) - NFPA 70 FIRE/LIFE SAFETY CODE 2017 FLORIDA BUILDING CODE (2015 IFC) INSTALLER NOTE: REFERENCE LATEST SPRINT CONSTRUCTION STANDARDS 11-1 I811 OBTAIN LOCATION OF PARTICIPANTS UNN DERGROUND FACILITIES BEFORE YOU DIG IN FLORIDA, CALL SUNSHINE 811 TOLL FREE: 1-800-432-4770 OR rm C w .Sunshine811.com FLORIDA STATUTE Know what's below. REQUIRES MIN OF 2 Call DAYS NOTICE Call before you dig. BEFORE YOU EXCAVATE Sprint')OF, �ti,`� J 54GW MADISON Si. 17TH F OCR CHICAGCIL 11111 W I R E L E S S 311895.4977 A NOKIA COMPANY A GPD GROUP, INC. LIC. # - 30920 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 GPD JOB#: 2018724.25.JA73XCO54.01 "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM AS OF �rSDqULV REGISTERED UNDEROF FLORI AW t 1-4�J'ii JA73XC054F17.1 JA73XCO54 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 REVISIONS REV. DATE DESCRIPTION INITIALS A 02/05/18 ISSUED FOR REVIEW JDP 0 06/20/18 ISSUED FOR REVIEW DRD o O�� • �/ q \ LEB C,QITqTJpN U N L �I I(;&RFT , "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM AS OF �rSDqULV REGISTERED UNDEROF FLORI AW t 1-4�J'ii JA73XC054F17.1 JA73XCO54 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 : � r r STATE OF o O�� • �/ "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM AS OF �rSDqULV REGISTERED UNDEROF FLORI AW t 1-4�J'ii JA73XC054F17.1 JA73XCO54 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 PROJECT SCO _E SPRINT: 1. INSTALL ±10' OF NEW 2" CONDUIT FROM PROPOSED MMP IN ROW TO Y -INTERCEPT INTO EXISTING 2" CONDUIT FROM EXISTING MMP. 2. INSTALL HH AT Y -INTERCEPT POINT. FIELD SERVICI=S: Sprint' 1. INSTALL ±25' NEW FIBER IN EXISTING 2" CONDUIT FROM TELCO/PPC CABINET TO MMBTS. 2. REMOVE LEGACY COPPER EQUIPMENT FROM TELCO/PPC CABINET. DFV: ^M 1. INSTALL ±630' OF NEW FIBER IN EXISTING 2" CONDUIT FROM HOFFMAN BOX ON H -FRAME TO THE MMP. ow MADISON ST 2. INSTALL NEW MMP HH. 17THFLOOR CHICAGO,L 60661 SITE NOTES: W I R E L E S S V312895.4977 1. SITE INFORMATION WAS PREPARED USING EXISTING DOCUMENTATION AND/OR SITE MEASUREMENTS AND SHOULD NOT BE INTERPRETED AS AN ACCURATE A NOKIA" COMPANY BOUNDARY SURVEY. 2. THIS SITE PLAN WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT AND IS SUBJECT TO ALL THE EASEMENTS AND RESTRICTIONS OF RECORD. ' 3. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING A PRIVATE UTILITY LOCATE IF NEEDED TO DETERMINE THE UNDERGROUND STRUCTURES ON PRIVATE PROPERTY. THESE DRAWINGS DO NOT /'. 041, _ DEPICT ALL UNDERGROUND UTILITIES IN THE PROJECT AREA. ROLES AND RESPONSIBILITIES: SPRINT R&R: GPD GROUP, INC. 1. SPRINT TO PERFORM ALL NEW CONDUIT INSTALLATIONS FROM THE MMP TO THE PPC AND FROM PPC TO MMBTS. LIC. n - 30920 2. IF NEW CONDUIT IS REQUIRED - SPRINT TO ASSUME RESPONSIBILITY FOR INSTALLATION OF FDP. FDP TO BE INSTALLED IN TELCO BOX UNLESS OTHERWISE NOTED, 520 South Main Street, Suite 2531 Akron, OH 44311 FIELD SERVICE R&R: 330.572.2100 Fax: 330.572,2102 1. FIELD SERVICES TO PULL FIBER FROM FDP TO MMBTS. m 2. WHEN USING ALL EXISTING CONDUIT - FIELD SERVICES TO INSTALL FDP. FDP ASSUMED TO BE INSTALLED IN TELCO BOX UNLESS NOTED OTHERWISE. x 0 DARK FIBER VENDOR R&R: OPDJOB#: 2o1672425AA73XC054.01 1. DARK FIBER VENDOR RESPONSIBLE FOR ANY NEW CONDUIT INSTALLATION, FIBER WORK OR MMP CONSTRUCTION REQUIRED FROM THE ROW TO THE MMP. E 2. DARK FIBER VENDOR RESPONSIBLE FOR PULLING FIBER MMP TO FDP. REVISIONS REV. DATE DESCRIPTION INITIALS w GENERAL NOTES SCALE G NTS A 02/05/18 ISSUED FOR REVIEW JDP °11 0 06/20/16 ISSUED FOR REVIEW ORD w EXISTING SPRINT EQUIPMENT SEE DETAIL 2 AAV -1 1 1 U C', t EXISTING WATER TOWER 5 EXISTING WATER TCWER I w w I LEONARDO A. SFERRA —I 1 LICENSE NO. 80859 EXISTING ICE BRIDGE s r�. I / r �\ N L �r o I r r It At EXISTING BBS CABINET �" •� EXISTING MMBTS CABINET o EXISTING ACCESS ROAD — jf PROPOSED DFV MMP HH I I EXISTING SPRINT CONCRETE STATE OF ((� ° 30.34933° j EQUIPMENT PAD % ,• s! -81.41348° I w I ® --J � FIELD SERVICES TO INSTALL a ±25' OF NEW FIBER IN CABINET ON H -FRAME A .� EXISTING 2" CONDUIT FROM �m ,�� s�NAL % TELCO NID TO TELCO/PPC m CABINET TO MMBTS, FIELD SERVICES TO REMOVE LEGACY COPPER EQUIPMENT �g FROM TELCO/PPC CABINET. EXISTING TELCO NID ON PREPARED CBYTIF METHAT THESE UNDER PLANS DIRE CT EXISTING MEET ME POINT w H -FRAME L m � SUPERVISION AND THAT I AM A DULY W REGISTERED UNDER THE LAWS �O. THE AT ll� OF FLORIDA" ll— w c» mx BER--- FIBER-- FIBER-- FIBER— FIBER-- FIBERm - —FIBE FIBER— FIBER— FIBER-- FIBE JA73XC054F17.1 U EXISTING MULTI -TENANT JA73XCO54 H -FRAME 2301 MAYPORT ROAD EXISTING SPRINT ATLANTIC BEACH, FL 32233 SPRINT TO INSTALL POWER METER NEW HH OVER Y -INTERCEPT DFV TO INSTALL ±630' OF SHEET TITLE POINT. DFV TO INSTALL ±630'OF m NEW FIBER IN EXISTING 2" NEW FIBER IN EXISTING 2" CONDUIT FROM HOFFMAN CONDUIT FROM HOFFMAN BOX ON H -FRAME TO THE DARK FIBER SPRINT TO INSTALL ±101 OF NEW 2" CONDUIT BOX ON H -FRAME TO THE MMP. SITE PLANS FROM PROPOSED MMP IN ROW TO Y -INTERCEPT MMP. INTO EXISTING 2" CONDUIT FROM EXISTING MMP ® DFV TO INSTALL ±10' OF NEW FIBER IN NEW 2" CONDUIT FROM PROPOSED MMP IN ROW TO Y -INTERCEPT INTO ® SHEET NUMBER EXISTING 2" CONDUIT FROM EXISTING MMP ��� OVERALL SITE PLAN ® °°(22x34) DETAILED SITE PLAN 15' 3' S' SORE' 3332-,10„°(22x34) 0 4' F 16' SCALE. 1/16'-1' 0 c 0 24"x36"x24" HANDHOLE WITH COVER, ro (NEW BASIS PCA243618S-IPC OR 3/8"x3" HEX BOLT APPROVED EQUAL) (2 EACH END) BOX NOTES 1. POLYMER CONCRETE CONSTRUCTION 2. STACKABLE FOOT 3. APPROXIMATE WEIGHT- 150LBS. NOTES 1. THIS UNIT HAS A WEIGHT RATING OF 20,800 LBS AND SHOULD BE PLACED IN LOCATIONS THAT MAY NOT HAVE AN OCCASIONAL BUT NON -DELIBERATE LIGHT TO HEAVY VEHICLE EXPOSURE. 2. THIS PRODUCT SHOULD NOT BE PLACED IN FULL TRAFFIC OR DELIBERATE VEHICLE TRAFFIC AREA. THIS ALL AREAS REQUIRING "H" TYPE RATING. 24"xW"x24" HANDHOLE DETAIL S°ALE NTS EXISTING WATER TOW_ R LEG 24"x36"x24" HANDHOLE WITH COVER, (NEW BASIS PCA2436185-IPC OR APPROVED EQUAL) ATTACH VENDOR FIBER TAG TO CABLE CRUSHED STONE BASE, EXTEND 6" BEYOND PERIMETER OF HANDHOLE FOOTPRINT SUITABLE DIRT INSTALL 1" (MIN.) AGL SECTION VIEW - INSTALLATION - PLAN VIEW - EXCAVATION HANDHOLE INSTALLATION DETAIL EXISTING SPRINT TELCO NID EXISTING SPRINT TELCO/PPC CABINET FIELD SERVICES TO REMOVE LEGACY COPPER EQUIPMENT FROM TELCO/PPC CABINET. FINISHED GRADE, OR GROUNDTRENCH 6" WIDE WARNING TAPE COVER MATCH SLOPE AND 12"-18" TO RUN THE ENTIRE THICKNESS OF EXISTING LENGTH OF TRENCH 8" TO 10" BELOW GRADE .COMPACTED BACKFILL WITH SATISFACTORY SUITABLE DIRT m __ NATIVE OR IMPORTED - + BACKFILL SOIL TO 9S% PROCTOR � — �___w COMPACTED CLEAN FILL COMPACTED HOPEBORE DUCT LID NOTES OR SCH 40 PVC CONDUIT CONDUIT (2) 1" UNDISTURBED SOIL INNER -DUCTS W/ FIBER TRENCH DETAIL 1. POLYMER CONCRETE CONSTRUCTION STRANDED W/ ORANGE (TO EQUIPMENT PAD/SOURCE) 24" 2. STANDARD LOAD RATING: 20,800 LBS 12AWG LOCATING 35-5/8" WIRE OR TRACEABLE 3. TWO (2) BOLT DOWN LOCATIONS MULETAPE - 4. NON-SKID SURFACE STANDARD 5. ALL CONDUITS SHALL BE CLEAN INSIDE WITH NO DIRT OR ANY OTHER 5. APPROXIMATE WEIGHT- 104LBS. 6. ALL BENDS MUST SWEEP 36" RADIUS AND MAXIMUM OF 3 SWEEPS. ANY 6. NAME PLATE: SPRINT BOLTS DOWNS 2 7. THE CONTRACTOR SHALL VERIFY AND FOLLOW THE UTILITY COMPANY LIFT PINS (2) SPECIFICATIONS FOR INSTALLATIONS. 2"x8" NAMEPIATE NON-SKID SURFACE RECESS (1 PL), (STANDARD) SPRINT 26" 37-5/8" 24"x36"x24" HANDHOLE WITH COVER, ro (NEW BASIS PCA243618S-IPC OR 3/8"x3" HEX BOLT APPROVED EQUAL) (2 EACH END) BOX NOTES 1. POLYMER CONCRETE CONSTRUCTION 2. STACKABLE FOOT 3. APPROXIMATE WEIGHT- 150LBS. NOTES 1. THIS UNIT HAS A WEIGHT RATING OF 20,800 LBS AND SHOULD BE PLACED IN LOCATIONS THAT MAY NOT HAVE AN OCCASIONAL BUT NON -DELIBERATE LIGHT TO HEAVY VEHICLE EXPOSURE. 2. THIS PRODUCT SHOULD NOT BE PLACED IN FULL TRAFFIC OR DELIBERATE VEHICLE TRAFFIC AREA. THIS ALL AREAS REQUIRING "H" TYPE RATING. 24"xW"x24" HANDHOLE DETAIL S°ALE NTS EXISTING WATER TOW_ R LEG 24"x36"x24" HANDHOLE WITH COVER, (NEW BASIS PCA2436185-IPC OR APPROVED EQUAL) ATTACH VENDOR FIBER TAG TO CABLE CRUSHED STONE BASE, EXTEND 6" BEYOND PERIMETER OF HANDHOLE FOOTPRINT SUITABLE DIRT INSTALL 1" (MIN.) AGL SECTION VIEW - INSTALLATION - PLAN VIEW - EXCAVATION HANDHOLE INSTALLATION DETAIL EXISTING SPRINT TELCO NID EXISTING SPRINT TELCO/PPC CABINET FIELD SERVICES TO REMOVE LEGACY COPPER EQUIPMENT FROM TELCO/PPC CABINET. FINISHED GRADE, OR GROUNDTRENCH 6" WIDE WARNING TAPE COVER MATCH SLOPE AND 12"-18" TO RUN THE ENTIRE THICKNESS OF EXISTING LENGTH OF TRENCH 8" TO 10" BELOW GRADE .COMPACTED BACKFILL WITH SATISFACTORY SUITABLE DIRT m __ NATIVE OR IMPORTED - + BACKFILL SOIL TO 9S% PROCTOR � — �___w COMPACTED CLEAN FILL Sprint' Jn. CH W MADISON ST. nre FLDDR CHICAGO, IL 60661 W I R E L E S S 312885.491] A NOKIA COMPANY A GPD GROUP, INC. LIC. # - 30920 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 GPD JOB#: 2018724.25.JA73XCO54..1 tv PATE DESCRIPTION INITIALS A 02/05/18 ISSUED FOR REVIEW JDP I D I 06/20/18 I ISSUED FOR REVIEW I DRD NOT FO T lj;( I}NLESS LA. 2 TRENCH DETAIL N.T.S. I• .--•.. LEONARDO A. SFERRA '° 9 LICENSE NO. 80859 INO "59 s � � STATE OF q 4, raj ,mss` tOR10 ' N, s s/n \\X HEREBY "I HEREBY CERTIFY THAT THESE'PiL tS&.)4JR'c' PREPARED BY ME OR UNDER MY DIRECT SUPERVISIONAND THAT I AM A DULY REGISTERED UNDER THE LAWS OFT EST TO DARK FIBER OF FLORIDA" DFV TO INSTALL PROVIDER SPLICE POINT 1:630' OF NEW FIBER IN EXISTING 2" JA73XCO54F17.1 PROPOSED IN FROM EXISTING I JA73XCO54 DFV MMP HH I-ELCO/PPC CABINET MMBTS t 2301 MAYPORT ROAD 30.34933° 70 PROPOSED CABINET I ATLANTIC BEACH, FL 32233 -81.41348° )!,f -INTERCEPT. EXISTING SPRINT TO INSTALL SHEET TITLE MEET ME NEW HH OVER POINT HH Y -INTERCEPT DARK FIBER POINT. GRADE EQUIPMENT DETAILS SPRINT TO INSTALL ±10' OF NEW 2" CONDUIT FROM PROPOSED MMP IN ROVI TO Y -INTERCEPT FIELD SERVICES TO INSTALL INTO EXISTING 2" CONDUIT FROM EXISTING MMP ±25' OF NEW FIBER IN DFV TO INSTALL ±10' OF NEW FIBER IN NEW 2" CONDUIT EXISTING 2" CONDUIT FROM SHEET NUMBER FROM PROPOSED MMP IN ROVJ TO Y -INTERCEPT INTO TELCO NID TO TELCO/PPC EXISTING 2" CONDUIT FROM EKISTING MMP CABINET TO MMBTS. ��� FIBER SCHEMATIC SCALE 4 DETAIL NOT USED SCALE N.T.S 5 Nrc COMPACTED HOPEBORE DUCT NEW 3" SCH 40 PVC CLEAN FILL BED OR SCH 40 PVC CONDUIT CONDUIT (2) 1" UNDISTURBED SOIL INNER -DUCTS W/ FIBER TRENCH DETAIL TRACER WIRE (#12 AWG STRANDED W/ ORANGE (TO EQUIPMENT PAD/SOURCE) FOOTPRINT SHOWS PENCEL HANDHOLE. JACKET) FOR FIBER NOT TO SCALE 12AWG LOCATING WITHIN PRIVATE PARCEL WIRE OR TRACEABLE TO SPRINT PPC CABINET MULETAPE INSTALLED WITH A TRACER WIRE (#12 AWG STRANDED W/ ORANGE UTILITY TRENCH NOTES: Sprint' Jn. CH W MADISON ST. nre FLDDR CHICAGO, IL 60661 W I R E L E S S 312885.491] A NOKIA COMPANY A GPD GROUP, INC. LIC. # - 30920 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 GPD JOB#: 2018724.25.JA73XCO54..1 tv PATE DESCRIPTION INITIALS A 02/05/18 ISSUED FOR REVIEW JDP I D I 06/20/18 I ISSUED FOR REVIEW I DRD NOT FO T lj;( I}NLESS LA. 2 TRENCH DETAIL N.T.S. I• .--•.. LEONARDO A. SFERRA '° 9 LICENSE NO. 80859 INO "59 s � � STATE OF q 4, raj ,mss` tOR10 ' N, s s/n \\X HEREBY "I HEREBY CERTIFY THAT THESE'PiL tS&.)4JR'c' PREPARED BY ME OR UNDER MY DIRECT SUPERVISIONAND THAT I AM A DULY REGISTERED UNDER THE LAWS OFT EST TO DARK FIBER OF FLORIDA" DFV TO INSTALL PROVIDER SPLICE POINT 1:630' OF NEW FIBER IN EXISTING 2" JA73XCO54F17.1 PROPOSED IN FROM EXISTING I JA73XCO54 DFV MMP HH I-ELCO/PPC CABINET MMBTS t 2301 MAYPORT ROAD 30.34933° 70 PROPOSED CABINET I ATLANTIC BEACH, FL 32233 -81.41348° )!,f -INTERCEPT. EXISTING SPRINT TO INSTALL SHEET TITLE MEET ME NEW HH OVER POINT HH Y -INTERCEPT DARK FIBER POINT. GRADE EQUIPMENT DETAILS SPRINT TO INSTALL ±10' OF NEW 2" CONDUIT FROM PROPOSED MMP IN ROVI TO Y -INTERCEPT FIELD SERVICES TO INSTALL INTO EXISTING 2" CONDUIT FROM EXISTING MMP ±25' OF NEW FIBER IN DFV TO INSTALL ±10' OF NEW FIBER IN NEW 2" CONDUIT EXISTING 2" CONDUIT FROM SHEET NUMBER FROM PROPOSED MMP IN ROVJ TO Y -INTERCEPT INTO TELCO NID TO TELCO/PPC EXISTING 2" CONDUIT FROM EKISTING MMP CABINET TO MMBTS. ��� FIBER SCHEMATIC SCALE 4 DETAIL NOT USED SCALE N.T.S 5 Nrc 1. CONDUIT SIZE, TYPE, QUANTITY, AND SEPARATION DIMENSION TO BE VERIFIED WITH LOCAL UTILITY. 2. ALL UTILITY TRENCHES WITHIN THE FENCED COMPOUND OR UNDER ANY PORTION OF A GRAVEL DRIVE AND/OR ROADWAY SHALL BE BACKFILLED WITH ODOT#57 COMPACTED AGGREGATE. FOOTPRINT SHOWS PENCEL HANDHOLE. 3. ALL CONDUITS SHALL BE INSTALLED WITH 3/16" POLYPROPYLENE ROPE OTHER MANUFACTURERS (PULL STRING) SUITABLE FOR PULLING CABLE THROUGH DUCT. MAY VARY SLIGHTLY 4. ALL CONDUITS THAT ARE TO BE USED FOR FIBER/ALARM SHALL BE FROM THAT SHOWN INSTALLED WITH A TRACER WIRE (#12 AWG STRANDED W/ ORANGE JACKET). 5. ALL CONDUITS SHALL BE CLEAN INSIDE WITH NO DIRT OR ANY OTHER OBSTRUCTIONS. 6. ALL BENDS MUST SWEEP 36" RADIUS AND MAXIMUM OF 3 SWEEPS. ANY ADDITIONAL SWEEPS MUST BE APPROVED BY THE UTILITY COMPANY. 7. THE CONTRACTOR SHALL VERIFY AND FOLLOW THE UTILITY COMPANY SPECIFICATIONS FOR INSTALLATIONS. Sprint' Jn. CH W MADISON ST. nre FLDDR CHICAGO, IL 60661 W I R E L E S S 312885.491] A NOKIA COMPANY A GPD GROUP, INC. LIC. # - 30920 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 GPD JOB#: 2018724.25.JA73XCO54..1 tv PATE DESCRIPTION INITIALS A 02/05/18 ISSUED FOR REVIEW JDP I D I 06/20/18 I ISSUED FOR REVIEW I DRD NOT FO T lj;( I}NLESS LA. 2 TRENCH DETAIL N.T.S. I• .--•.. LEONARDO A. SFERRA '° 9 LICENSE NO. 80859 INO "59 s � � STATE OF q 4, raj ,mss` tOR10 ' N, s s/n \\X HEREBY "I HEREBY CERTIFY THAT THESE'PiL tS&.)4JR'c' PREPARED BY ME OR UNDER MY DIRECT SUPERVISIONAND THAT I AM A DULY REGISTERED UNDER THE LAWS OFT EST TO DARK FIBER OF FLORIDA" DFV TO INSTALL PROVIDER SPLICE POINT 1:630' OF NEW FIBER IN EXISTING 2" JA73XCO54F17.1 PROPOSED IN FROM EXISTING I JA73XCO54 DFV MMP HH I-ELCO/PPC CABINET MMBTS t 2301 MAYPORT ROAD 30.34933° 70 PROPOSED CABINET I ATLANTIC BEACH, FL 32233 -81.41348° )!,f -INTERCEPT. EXISTING SPRINT TO INSTALL SHEET TITLE MEET ME NEW HH OVER POINT HH Y -INTERCEPT DARK FIBER POINT. GRADE EQUIPMENT DETAILS SPRINT TO INSTALL ±10' OF NEW 2" CONDUIT FROM PROPOSED MMP IN ROVI TO Y -INTERCEPT FIELD SERVICES TO INSTALL INTO EXISTING 2" CONDUIT FROM EXISTING MMP ±25' OF NEW FIBER IN DFV TO INSTALL ±10' OF NEW FIBER IN NEW 2" CONDUIT EXISTING 2" CONDUIT FROM SHEET NUMBER FROM PROPOSED MMP IN ROVJ TO Y -INTERCEPT INTO TELCO NID TO TELCO/PPC EXISTING 2" CONDUIT FROM EKISTING MMP CABINET TO MMBTS. ��� FIBER SCHEMATIC SCALE 4 DETAIL NOT USED SCALE N.T.S 5 Nrc Im CURRENT MEET ME POINT s°ALE CONDUIT RUN BEHIND MMBTS SALE SCALE N.T.S NT.s 2 H -FRAME 3 i N.T.S. Y i - r Y -•-. - ' . Y INTERCEPT 77 EKtST COINWT ` 1� 'NSTALL Y' SPLIT a NEW VG TMJ NH4V VAULT BY &PRINT c u j I PROPOSED MEET ME POINT 41 7 INSIDE MMBTS CABINET 4 PROPOSED CONDUIT PATH EL-ImErYl INSIDE TELCO PPC CABINET 5 Y -INTERCEPT LOCATION LEONARDO A. SFERRA LICENSE NO. 80859 N.T.S SOA 8 I EQUIPMENT OVERVIEW NTS Sprint'- SSW 17 MADISON Si. .J17TH F OOR CHICAGO, IL 60661 W I. R E L E S S 3,1695.4977 A NOKIA" COMPANY A 4jarEah,, GPD GROUP, INC. LIC. # - 30920 520 South Main Street, Suite 2531 Akron, 01-144311 330.572.2100 Fax: 330.572.2102 GPD JOB#: 2W1 724.25.JA73XC054.01 REVISIONS REV. DATE I DESCRIPTION INITIALS A 02105/18 ISSUED �1.1 REVIEW 11110 � 06/20/18 ISSUED FOR REVIEW DRD NO LFREiWtFjj 1OAQN SET STATE OF f ` 6_ 0 (� LEPARED BY ME OR UNDER MY DIREC - PERVISION AND THAT I AM A DULY GISTERED UNDER THE LAWS OF THE STA OF FLORIDA' j JA73XC054F17.1 I JA73XCO54 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 SHEET TITLE SITE PHOTOS SHEET NUMBER AAV-3 9 n 5 Y -INTERCEPT LOCATION LEONARDO A. SFERRA LICENSE NO. 80859 N.T.S SOA 8 I EQUIPMENT OVERVIEW NTS Sprint'- SSW 17 MADISON Si. .J17TH F OOR CHICAGO, IL 60661 W I. R E L E S S 3,1695.4977 A NOKIA" COMPANY A 4jarEah,, GPD GROUP, INC. LIC. # - 30920 520 South Main Street, Suite 2531 Akron, 01-144311 330.572.2100 Fax: 330.572.2102 GPD JOB#: 2W1 724.25.JA73XC054.01 REVISIONS REV. DATE I DESCRIPTION INITIALS A 02105/18 ISSUED �1.1 REVIEW 11110 � 06/20/18 ISSUED FOR REVIEW DRD NO LFREiWtFjj 1OAQN SET STATE OF f ` 6_ 0 (� LEPARED BY ME OR UNDER MY DIREC - PERVISION AND THAT I AM A DULY GISTERED UNDER THE LAWS OF THE STA OF FLORIDA' j JA73XC054F17.1 I JA73XCO54 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 SHEET TITLE SITE PHOTOS SHEET NUMBER AAV-3 9 AUGMENT ID: SPRINT SITE CASCADE SPRINT SITE NAME: TOWER TYPE: LANDLORD SITE ID: SITE INFORMATION SPRINT SITE CASCADE: SPRINT SITE NAME: LANDLORD SITE ID: SITE ADDRESS COUNTY: MAP/PARCEL #: LATITUDE: LONGITUDE: LAT/LONG TYPE: GROUND ELEVATION: CURRENT ZONING: JURISDICTION. OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: A.D.A. COMPLIANCE: PROPERTY OWNER: TOWER OWNER: CARRIER/APPLICANT: ELECTRIC PROVIDER: FIBER PROVIDER: JA73XCO54 ATLANTIC BEACH TBD JA73XC054F17'.1 JA73XCO54 ATLANTIC BEFIICH WATER TOWER TBD 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 DUVAL 1693980070 - 30°20' 59.802" N (30.349525°) 81" 24'48.67" W (-81.41171666°) NAD83 42.651 ±FT. OR CITY OF ATLANTIC BEACH U VB FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 SPRINT 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251-2650 FLORIDA POWER & LIGHT (800) 226-3545 UNIT[ (727)471-5600 PROJECT TEAM SAC CONTACTS: SAC WIRELESS 540 W. MADISON ST., 17TH FLOOR CHICAGO. IL 60661 SPRINT CONTACTS: TBD TBD@SPRINT.COM A&E FIRM: GPD GROUP,INC. 520 SOUTH MAIN STREET, SUITE 2531 AKRON, OHIO 44311 JUSTIN BUTTERFIELD (330)572-2100 THE PARTIES ABOVE HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. Sprint° SPRINT DARK FIBER DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET AAV -1 DARK FIBER SITE PLANS AAV -2 DARK FIBER EQUIPMENT DETAILS AAV -3 SITE PHOTOS i ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME, PROJECT DESCRIPTION SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY. SPRINT: 1. INSTALL 110' OF NEW 2" CONDUIT FROM PROPOSED MMP IN ROW TO Y -INTERCEPT INTO EXISTING 2" CONDUIT FROM EXISTING MMP. 2. INSTALL HH AT Y -INTERCEPT POINT. FIELD SERVICES: 1. INSTALL ±25' NEW FIBER IN EXISTING 2" CONDUIT FROM TELCO/PPC CABINET TO MMBTS. 2. REMOVE LEGACY COPPER EQUIPMENT FROM TELCO/PPC CABINET. DFV: 1. INSTALL ±630'OF NEW FIBER IN EXISTING 2" CONDUIT FROM HOFFMAN BOX ON H -FRAME TO THE MMP. 2. INSTALL NEW MMP HH. SITE ADDRESS COUNTY: JURISDICTION 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 DUVAL CITY OF ATLANTIC BEACH APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK AND MATERIALS SHALL BE PERFOMRED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. BUILDING/DWELLING CODE STRUCTURAL CODE MECHANICAL CODE PLUMBING CODE ELECTRICAL CODE FIRE/LIFE SAFETY CODE 2017 FLORIDA BUILDING CODE (2015 IBC) TIA-222 - G ADDENDUM NO. 2 - 2017 FLORIDA BUILDING CODE (2015 IMC) 2017 FLORIDA BUILDING CODE (2015 IPC) 2014 NATIONAL ELECTRICAL CODE (NEC) - NFPA 70 2017 FLORIDA BUILDING CODE (2015 IFC) INSTALLER NOTE: REFERENCE LATEST SPRINT CONSTRUCTION STANDARDS LEONARDO A. SFERRA LICENSE NO. 80859 TO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN FLORIDA. CALL SUNSHINE 811 TOLL FREE: 1-800-432-4770 OR vAvw.Sunshine811.com ' FLORIDA STATUTE Know what's below. REQUIRES MIN OF2 WORKING DAYS NOTICE Call before you dig. BEFORE YOU EXCAVATE Sprint' 54017 MADISON IT 1711 FLOOR CHICAGO.. IL 11111 W R E L E S S 312 BBS 4977 ANOKIA COMPANY A GPD GROUP, INC. LIC. # - 30920 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 GPD JOB#: 2018724.25.JA73XCO54.01 REVISIONS REV. DATE DESCRIPTION INITIALS A 02/05/18 ISSUED FOR REVIEW JDP 0 06/20/18 ISSUED FOR REVIEW ORD 11 LI �, II \NW�EB NS fRC1GTIIsA ���% 1 � r • STATE OF % 01 t%` ��% FSS � 0R10P -��L� "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED BV ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED UNDEROW THE i OF THE FLORIDAdS�I� JA73XC054F17.1 JA73XCO54 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 PROJECT SCOPE: SPRINT: 1. INSTALL ±10' OF NEW 2" CONDUIT FROM PROPOSED MMP IN ROW TO Y -INTERCEPT INTO EXISTING 2" CONDUIT FROM EXISTING MMP. 2. INSTALL HH AT Y -INTERCEPT POINT. FIELD SERVICES: 11 Sprint V p ri n t 1. INSTALL ±25NEW FIBER IN EXISTING 2" CONDUIT FROM TELCO/PPC CABINET TO MMBTS. 2. REMOVE LEGACY COPPER EQUIPMENT FROM TELCO/PPC CABINET. DFV: 1. INSTALL ±630'OF NEW FIBER IN EXISTING 2" CONDUIT FROM HOFFMAN BOX ON H -FRAME TO THE MMP. ... 17TH FLOOR � WW, MADISON sr. 2. INSTALL NEW MMP HH. CH CAGO, IL 60661 SITE NOTES: 1. SITE INFORMATION WAS PREPARED USING EXISTING DOCUMENTATION AND/OR SITE MEASUREMENTS AND SHOULD NOT BE INTERPRETED AS AN ACCURATE W R E L E S S 312.895.4977 A NOKIA COMPANY BOUNDARY SURVEY. A. 2. THIS SITE PLAN WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT AND IS SUBJECT TO ALL THE EASEMENTS AND RESTRICTIONS OF RECORD. 3. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING A PRIVATE UTILITY LOCATE IF NEEDED TO DETERMINE THE UNDERGROUND STRUCTURES ON PRIVATE PROPERTY. THESE DRAWINGS DO NOT DEPICT ALL UNDERGROUND UTILITIES IN THE PROJECT AREA. ROLES AND RESPONSIBILITIES: SPRINT R&R: GPD GROUP, INC. 1, SPRINT TO PERFORM ALL NEW CONDUIT INSTALLATIONS FROM THE MMP TO THE PPC AND FROM PPC TO MMBTS. LIC. u - 30920 2. IF NEW CONDUIT IS REQUIRED - SPRINT TO ASSUME RESPONSIBILITY FOR INSTALLATION OF FDP. FDP TO BE INSTALLED IN TELCO BOX UNLESS OTHERWISE NOTED. 520 South Main Street, Suite 2531 Akron, OH 44311 FIELD SERVICE R&R: 330.572.2100 Fax: 330.572.2102 1. FIELD SERVICES TO PULL FIBER FROM FDP TO MMBTS. i 2. WHEN USING ALL EXISTING CONDUIT - FIELD SERVICES TO INSTALL FDP. FDP ASSUMED TO BE INSTALLED IN TELCO BOX UNLESS NOTED OTHERWISE. GPD JOBM 2018724.25.JA73XC054 01 DARK FIBER VENDOR R&R: - 1. DARK FIBER VENDOR RESPONSIBLE FOR ANY NEW CONDUIT INSTALLATION, FIBER WORK OR MMP CONSTRUCTION REQUIRED FROM THE ROW TO THE MMP. REVISIONS i 2. DARK FIBER VENDOR RESPONSIBLE FOR PULLING FIBER MMP TO FDP. GENERAL NOTES SCALE 3 OATS DESCRIPTION INITIALS A 02/05/18 ISSUED FOR REVIEW JDP N.T.S. 0 06/20/18 ISSUED FOR REVIEW ORD EXISTING SPRINT EQUIPMENT SEE DETAIL 2 AAV -1 0 1 1 ' EXISTING WATER TOWER EXISTING WATER TOWER I N — — LEONARDO A. SFERRA LICENSE NO. 80859 rr EXISTING ICE BRIDGE t0±. �f�fcGN6j� L E ZIP EXISTING BBS CABINET EXISTING ACCESS ROAD PROPOSED DFV MMP HH I 30.34933' I I -81.41348° _m EXISTING MMBTS CABINET -- j r EXISTING SPRINT CONCRETE s ` EQUIPMENT PAD ±25 OF NEW FIBER IN FIELD SERVICES TO IN STALL CABINEXISTIET ON H NG TELCO/PPC EXISTING 2" CONDUIT FROM �� :LEGACY r;r. 59E519 STATE OF 0 �'c�OR10P��4�, `pS �� vNAL TELCO NID TO TELCO/PPC m CABINET TO MMBTS. FIELD SERVICES TO REMOVE COPPER EQUIPMENT EXISTING MEET ME POINT m 4 CNN m BER FIBER— FIBER--- FIBER— FIBER FIBER — FIBE FIBER— FIBER-- FIBER— FIBER----' I- Om FROM TELCO/PPC CABINET. EXISTING TELCO NID ON -FRAME m "I HEREBY CERTIFY THAT THESE PLANS WERE. PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED UNDER THE LAWS�OF THE AT OF FLORIDA" ll— J,473XC054F17.1 E 1 LJ —EXISTINGr MULTI -TENANT H FRAME w JA73XCO54 2301 MAYPORT ROAD m EXISTING SPRINT ATLANTIC BEACH, FL 32233 SPRINT TO INSTALL POWER METER NEW HH OVER Y -INTERCEPT DFV TO INSTALL ±630' OF SHEET TITLE DFV TO INSTALL ±630' OF POINT. NEW FIBER IN EXISTING 2" CONDUIT FROM HOFFMAN m NEW FIBER IN EXISTING 2" CONDUIT FROM HOFFMAN BOX ON H -FRAME TO THE DARK FIBER BOX ON H -FRAME TO THE SPRINT TO INSTALL ±10' OF NEW 2" CONDUIT MMP, FROM PROPOSED MMP IN ROW TO Y -INTERCEPT MMP' w SITE PLANS INTO EXISTING 2" CONDUIT FROM EXISTING MMP ® DFV TO INSTALL ±10'OF NEW FIBER IN NEW 2" CONDUIT FROM PROPOSED MMP IN ROW TO Y -INTERCEPT INTO SHEET NUMBER® EXISTING 2" CONDUIT FROM EXISTING MMP _ AAV OVERALL SITE PLAN ® SCALE' 1/16"=1'-0"(22x34) DETAILED SITE PLAN 0 15' 3' 5' SCALE. 3/16"=T -0'(22x34) 2 (OR) 1/32"=1'D"(11x17) (OR) 3/32"=1' 0" (11x17) LID NOTES 24"x36"x24" HANDHOLE WITH COVER, (NEW BASIS PCA2436185-IPC OR INS ALL 1" (MIN.) APPROVED EQUAL) FINISHED GRADE, OR GROUND TRENCH 6" WIDE WARNING TAPE COVER MATCH SLOPE AND 12" 18" TO RUN THE ENTIRE THICKNESS OF EXISTING LENGTH OF TRENCH 8" Sprint* 1. POLYMER CONCRETE CONSTRUCTION TO 10" BELOW GRADE 24" 2. STANDARD LOAD RATING: 20,800 LBS ATTACH VENDOR - snow r,HF 3. TWO (2) BOLT DOWN LOCATIONS77' ---•----.-.. 35-518" 4. NON-SKID SURFACE STANDARD - - - - - - - - - _ _ _ 5. APPROXIMATE WEIGHT- 104LB5. FIBER TAG TO CABLE - 7 Y '77- z x v .- COMPACTED BAC BACKFILL - _ -- 6. NAME PLATE: SPRINT �, II I` Is WITH SATISFACTORY �� DOmsr nrncLooR `��t. J cnlcnco,IL6oss1 O .::::::. -'---------' - oo SUITABLE DIRT NATIVE OR IMPORTED T—'N-,. '. W I R E L E S S 312 4977 - - - - FIBER COIL _ BACKFILL ._ SOILTO95%PROCTOR a ANOKIa"coMPANv BOLTS DOWNS 2 LIFT PINS (2) COMPACTED CLEAN FILL - 2"x8" NAMEPLATIi NON-SKID SURFACE RECESS (1 PL), SPRINT ODUCT COMPACTED NEW 3" SC 40 PVC CLEAN FILL BED Alm (STANDARD) io OR SCH 40 PVC 1" CONDUIT (2) UNDISTURBED SOIL 26" C CONDUIT INNER -DUCTS W/ FIBER TRENCH DETAIL TRACER WIRE (#12 AWG 375/8" STRANDED Wt ORANGE (TO EQUIPMENT PAD/SOURCE) JACKET) FOR FIBER NOT TO SCALE GPD GROUP, INC. 12AWG LOCATING WITHIN PRIVATE PARCEL LTC. # - 30920 CRUSHED STONE BASE, EXTEND WIRE OR TRACEABLE 6" BEYOND PERIMETER OF TO SPRINT PPC CABINET 520 South Main Street, Suite 2531 MULETAPE HANDHOLE FOOTPRINT Akron, OH 44311 .24"x36"x24" HANDHOLE WITH COVER, SECTION VIEW - INSTALLATION - UTILITY TRENCH NOTES: 330.572.2100 Fax: 330.572.2102 do NEW BASIS PCA243618S-IPC OR 4PPROVED EQUAL) 1. CONDUIT SIZE, TYPE, QUANTITY, AND SEPARATION DIMENSION TO BE e 3/8"x3" HEX BOLT SUITABLE DIRT VERIFIED WITH LOCAL UTILITY. L (2 EACH END) BACKFILL 2. ALL UTILITYTRENCHES WITHIN THE FENCED COMPOUND OR UNDER ANY GPD Job#: 2018724.25.JA73XC054.01 - PORTION OF A GRAVEL DRIVE AND/OR ROADWAY SHALL BE BACKFILLED REVISIONS i WITH ODOT 7 0 #5 COMPACTED C AGGREGATE. FOOTPRINT SHOWS3. ALL CONDUITS SHALL BE INSTALLED WITH 3/16" POLYPROPYLENE ROPE Rev. onTe DESCRIPTION INITIALS A 02/05/18 ISSUED FOR REVIEW JDP 1. P 1. POLYMER CONCRETE CONSTRUCTION PENCEL HANDHOLE . OTHER MANUFACTURERS (PULL STRING) SUITABLE FOR PULLING CABLE THROUGH DUCT. ? i. STACKABLE FOOT MAY VARY SLIGHTLY 4. ALL CONDUITS THAT ARE TO BE USED FOR FIBER/ALARM SHALL BE = 3. APPROXIMATE WEIGHT- 150LB5. i FROM THAT SHOWN INSTALLED WITH A TRACER WIRE (#12 AWG STRANDED W/ ORANGE 0 06/20/18 ISSUED FOR REVIEW DRD JACKET). - 5. ALL CONDUITS SHALL BE CLEAN INSIDE WITH N T 0 DIRT OR ANY OTHER OBSTRUCTIONS. - NOTES 6. ALL BENDS MUST SWEEP 36" RADIUS AND MAXIMUM OF 3 SWEEPS. ANY I 1. THIS UNIT HAS A WEIGHT RATING 20,800 LBS AND SHOULDPLACED IN PLAN VIEW - EXCAVATION ADDITIONAL SWEEPS MUST BE APPROVED BY THE UTILITY COMPANY. � LOCATIONS THAT MAY NOT HAVE A A OCCASIONAL BUT NON -DELIBERATE 7. THE CONTRACTOR SHALL VERIFY AND FOLLOW THE UTILITY COMPANY LIGHT TO HEAVY VEHICLE EXPOSURE. SPECIFICATIONS FOR INSTALLATIONS. 2. THIS PRODUCT SHOULD NOT BE PLACED IN FULL TRAFFIC OR DELIBERATE VEHICLE TRAFFIC AREA. THIS ALL AREAS REQUIRING "H" TYPE RATING. NOT FSS LAB �•q C33 klla(�i 24"x36"x24" HANDHOLE DETAIL SCALE HANDHOLE INSTALLATION DETAIL SDALE 2 TRENCH DETAIL SCALE NT.S N.T s. N.TS '• EXISTING WATER EXISTING SPRINT TELCO LEONARDO A. SFERRA '' TOWER LEG MID LICENSE NO. 80859 EXISTING SPRINT i TELCO/PPC CABINET FIELD SERVICES TO REMOVE STAT E OF LEGACY COPPER EQUIPMENT FROM TELCO/PPC CABINET. /% "I HEREBY CERTIFY THA E EPL R PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED UNDER THE LAWS OF T}JE,S`.pyli 11--�L` OF FLORI DA" lyV\ TO DARK FIBER DFV TO INSTALL PROVIDER SPLICE ±630' OF NEW FIBER POINT JA73XCO54F17.1 IN E,KISTING 2" JA73XCO54 PROPOSED CON!DUITFROM EXISTING 2301 MAYPORT ROAD DFV MMP HH TELII,'O/PPC CABINET MMBTS 30.34933' TO PROPOSED CABINET ATLANTIC BEACH, FL 32233 -81.41348° Y -INTERCEPT. SHEET TITLE EXISTING SPRINT TO INSTALL MEET ME NEW HH OVER POINT HH Y -INTERCEPT DARK FIBER PAINT. EQUIPMENT DETAILS GRADE SPRINT TO INSTALL EW ±10' OF N 2" CONDUIT FROM PROPOSED MMP IN ROW TO Y -INTERCEPT FIELD SERVICES TO INSTALL INTO EXISTING 2" CONDUIT FROM EXISTING MMP t25' OF NEW FIBER IN DFV TO INSTALL t10' OF NEW FIBER IN NEW 2" CONDUIT EXISTING 2" CONDUIT FROM SHEET NUMBER FROM PROPOSED MMP IN ROW TO Y -INTERCEPT INTO TELCO NID TO TELCO/PPC EXISTING 2" CONDUIT FROM EXISTING MMP CABINET TO MMBTS. AAV_ 2 FIBER SCHEMATICS 4 DETAIL NOT USED NCALLE 5 _y Sprint �w x. 23 r 540WrMADI00R ST. .., MAYi. F ;,.- ;.. A w t �'' .� rTM# \ v 1 I✓rat� ( OHI�AG a L coo�1 VV I R E L E S S 31289549w7!7 . , A NOKIA COMPANY t .,. • ELL t;e.= / GPD GROUP, INC. ^ LIC. # - 30920 a 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 CURRENT MEET ME POINT -TSE CONDUIT RUN BEHIND MMBTS 2 H -FRAME SCALE N.T.S NTSE GPD JOB#: 2018724.25.JA73XC054 01 _ r W.T...,'MW REVISIONS REV. GATE DESCRIPTION INITIALS A 02/05/18 SUED FOR REVIE D - � r I OTNE VAULT BY SPRINEWN 0 06/20/18 ISSUED FOR REVIEW DRD Y r a r:t•8ae ti n s M �' i Oyu u t,x . • _' � - v$a 4. i<^'f"I' �"F � % A .. ,`�• I - MAS .L•O -1 � EXISTING CONDUIT _f I 'tea TO H FRAME/ PPC ` "� • '• t� ' "^ NOT FO ION UNLESS 8Et �]I N SET RS '� NEW VAULT LOCATION 1 MEET ME POINT IR ♦ • - Javi ��Q1 i. �.r` L s 30.34933,-81.41348, �j 08/30/2017 02:00:22 PM `. �- LEONARDO A. SFERRA ►:0 80II59 LICENSE NO. 80859 r PROPOSED MEET ME POINT N°TSE 4 SCALE PROPOSED CONDUIT PATH 5 N.T.S. Y -INTERCEPT LOCATION NT.S. STATE OF ; �'. ORIOQ �•` ' �� SM TE • .... .- -- : -':. -... . 4 5 REBY T F IA E PL RE PREPARED BY ME OR UNDER MV DIRE SUPERVISION AND THAT I AM A DULY r } u C _ REGISTERED U NDER THE LAWS OF THETA S OF FLORIDA' I— u I, 7n • JA73XC054F17.1 JA73XCO54 L i" 2301 MAYPORT ROAD ATLANTIC BEACH, FL 32233 Il' SHEET TITLE mxm Ila 4 SITE PHOTOS _ra + Jacks• • 30.34954,-81.41155,-31,0m,219'• SHEET NUMBER AAV -3 INSIDE MMBTS CABINET S°ALE % INSIDE TELCO PPC CABINET MASE $ EQUIPMENT OVERVIEW S°ALE 9 NTS. N.T.S.