1735 MARITIME OAK DR RES19-0044 DWGS6DESIGN SPECIFICATIONS: in with the 6th Edition 2017 Florida Building Project has been designed accordance e ( ) g Code, Residential, and the Florida Building Code, Existing Building (as applicable). DESIGN CRITERIA: Wind Design Method ASCE 7-10 Basic Wind Speed: 130 mph Building Risk Category: II Wind Exposure: B (Enclosed Structure) Building Classification: Residential Building Type: Type V Construction Wind -Borne Debris: NOT located in the wind-borne debris region Unless otherwise noted, project site considerations shall be the responsibility of the owner and/or contractor. Examples of such items include but shall not be limited to determination ofrade elevations drainage features and requirements special 9 .d g P associated with FEMA flood hazard and/or DEP zones. DESIGN DEAD LOADS: Floors: The design floor dead load of 12 psf assumes a floor system utilizing wood decking or wood subflooring over wood truss, wood I -joist, or solid sawn lumber framing. The floor covering is assumed to be carpet, vinyl, wood or ceramic tile. The Engineer shall be notified if the floor coverings differ from the noted assumptions 9 p Roofs: Metal or Shingle: 10 psf (Rafters) 7 psf (Wood Truss) Concrete or Clay Tile: 15 psf Refer to Architectural Plans for Roof Covering System DESIGN LIVE LOADS: Floors: Exterior Balconies: 40 psf Exterior Decks: 40 psf Stairs: 40 psf (or 300 Ib point load) Garages: 50 psf (or 2000 Ib point load) All Other Areas: 40 psf Attics: Without Storage: 10 psf With Limited Storage: 20 psf With Storage: 30 psf (fixed stair access) Roofs: Less than 4:12 slope: 20 psf 4:12 slope or greater: 16 psf DEFLECTION CRITERIA: Walls: Wind loads with plaster or stucco finish: L/360 Wind loads with other brittlefinishes: U24 0 Wind loads with flexible finishes: L/120 or L/180* * L/180 for exterior walls with interior gypsum board finish. Floors: Live Load: L/480 * Total Load: U240 * * Increased floor stiffness may be required by floor covering manufacturer Roofs: Live Load: L/240 Total Load: L/180 All window, door and soffit assemblies shall be designed to withstand the design pressures indicated below and shall be installed in accordance with the manufacturer's requirements. WIND PRESSURES ON WINDOWS, DOORS & SOFFITS (psf) AREA OF OPENING EDGE STRIP(5) INTERIOR ZONE (4) Pos Neg Pos Neg MITEK/USP ID FL # Fasteners Anchorage (U.O.N.) 0 to 20 sf 18.3 -24.5 18.3 -19.8 20.1 to 50 sf 17.5 -22.8 17.5 -19.1 50.1 to 100 sf 16.4 -20.6 16.4 -18.0 100.1 to 200 sf 15.5 -19.1 15.5 -17.1 200.1 to 500 sf 14.7 -17.41 14.7 -16.3 Soffit Design Pressure 1 18.3 -24.51 18.3 -19.8 ease uesign Pressure TYPICAL EDGE STRIP (5) a=6.0' 95.5U IjL;pl = tu.10 GENERAL NOTES: 1. The scope of these plans is limited to the structural requirements of this project. Architectural, civil (site), electrical, mechanical (plumbing and HVAC), waterproofing, and flashing requirements are not addressed in these plans. 2. It is the intent of the Engineer of Record (Engineer) that this work be performed in conformance with all requirements of the authorities having jurisdiction over this q 9 1 type of construction and occupancy. 3. The contractor is responsible for the means and methods of construction. It is the contractor's sole responsibility to determine the procedure, sequence, and temporary bracing as to insure the safety of the building and its component parts during construction. 4. The contractor shall verify all conditions and dimensions at the job site prior to commencing work. 5. The contractor shall supply, locate, and build into the work all inserts, anchors, angles, plates, openings, sleeves, hangers, slab depressions, or other components as may be required to attach and accommodate other work. 6. All details and sections shown on the structural drawings are intended to be typical and shall be construed to apply to any similar situation elsewhere in the work except where indicated otherwise. 7. Refer to the structural drawings for all structural details and sections. The contractor shall contact the Engineer for clarification in cases of conflict between the structural drawings and any drawings prepared by others prior to commencing work. 8. It is the owner's and/or contractor's responsibility to obtain a soils exploration report. The design of the project structure assumes an allowable soil bearing capacity of 2000 psf. The Engineer shall be notified if soil conditions encountered differ from the noted assumptions. All requirements for site preparation and soil compaction specified in the soils report shall be followed unless more stringent requirements are specified in these plans. CONCRETE: 1. All concrete work shall be in accordance with "Building Code Requirements for Structural Concrete," ACI 318-14, and "Specification for Structural Concrete," ACI 301. 2. All concrete shall have the following minimum compressive strength at 28 days: Slabs on grade, footings, and misc. concrete: fc=2500psi Structural slabs, walls, beams and columns: fc=3000psi Designated radon zones only - all concrete: fc=3000psi 3. Cement shall conform to "Specification for Portland Cement" ASTM C150 P ( ) 4. Aggregate shall conform to "Specification for Concrete Aggregates" (ASTM C33) 5. Water shall be clean and free of injurious amounts of oil, acids, alkalis, salts, organic material or other substances that are deleterious to concrete or steel reinforcement. 6. Reinforcing steel shall be ASTM A615 Grade 40 unless otherwise noted on the structural drawings. All reinforcing details shall conform to "Details and Detailing of Concrete Reinforcement," ACI 315, unless detailed otherwise on the structural drawings. 7. Tolerances for foundation and slab alignment as well as placement of reinforcement shall be in accordance with "Standard Tolerances for Concrete Construction and Materials," ACI 117. Footing or slab edges may be up to 1/2" inside of the sill plate. 8. All concrete slabs on grade shall be the thickness as indicated on the drawings over minimum 6 mil. polyethylene (visqueen) vapor barrier. Slabs shall be reinforced with 6x6 W1.4x1.4 WWF lapped 8" at edges and ends in conformance with ASTM -A 185, or fibermesh reinforcement shall be used with a minimum fiber length of 17' to 2 4" complying with ASTM C 1116. The dosage amount shall be 0.75 to 3.0 pounds per cubic yard in accordance with manufacturer's recommendations. 9. Slabs on grade shall bear on structural fill which shall be clean sand free of debris and other deleterious material. Structural fill shall be compacted to a density of at least 95% of the Modified Proctor Maximum Dry Density (ASTM D1557). Termite protection shall be provided in accordance with applicable code requirements. If soil treatment is used, the treatment shall be done after all excavation, backfilling, and compaction is completed. 10. structural fill. Structural fill shall be Footings may bear upon undisturbed soil or upon compacted to a density of at least 95% of the Modified Proctor Maximum Dry Density (ASTM D1557) for a depth of at least two feet (2'-0") below the bottom of the footing. 11. The following minimum concrete cover shall be provided for reinforcement: 3" Concrete cast against and permanently exposed to earth 2" Concrete exposed to earth or weather 1 Y2' Concrete not exposed to earth or weather 12. lap -spliced All continuous reinforcing steel in concrete shall be la s Iced with the following 9 P P 9 minimum lengths: #4 bars: 21" minimum #5 bars: 26" minimum #6 bars: 32" minimum 13. Reinforcement in footings shall be bent around corners or corner bars shall be used. 14. The contractor shall provide spacers, chairs, bolsters, etc., necessary to support reinforcing steel. Support items which bear on exposed concrete surfaces shall have ends which are plastic tipped or stainless steel. MASONRY: General: 1. All masonry work shall be in accordance with "Building Code Requirements for Masonry Structures," ACI 530-13, and Specifications for Masonry Structures," ACI 530.1-13 2. Grout shall conform to ASTM C476 with minimum 28 day compressive strength of 3000 psi per ASTM C1019. Grout shall be mixed to provide a slump between 8" to 11". 3. Mortar shall conform to ASTM C270 and be Type M or S. Type N mortar may be used in brick veneer. 4. The contractor shall be responsible for the design and installation of all flashing. Concrete Masonry (CMU): 1. Concrete masonry units (CMU) shall be ASTM C90-14 Hollow Load -Bearing Concrete Masonry Units, normal weight, with a minimum compressive strength of 1900 psi (fm=1900 psi). 2. All continuous reinforcing steel in masonry shall be lap -spliced with the following minimum lengths: #4 bars: 20" minimum #5 bars: 25" minimum #6 bars: 30" minimum 3. Grout all cells containing vertical reinforcement in 6-0" maximum lifts. 4. Provide cleanouts per ACI 530.1-13 in the bottom course of masonry when the wall height exceeds 6-0". 5. Beam reinforcement shall be continuous across control joints. 6. Reinforcing steel shall be ASTM A615 Grade 40 unless otherwise noted on the structural drawings. Clay Masonry (Brick): 1. Brick shall conform to ASTM C62, C216, or C652 for Building Brick, Facing Brick, and Hollow Brick, respectively. Grade MW shall be used. 2. Brick veneer shall be anchored with approved ties spaced no more than 16" o.c. vertical and 16" o.c. horizontal. Additional ties shall be provided around all wall openings greater than 16" in either direction, and shall be spaced no more than 36" o.c. and placed within 12" of the openings. 3. Strand wire veneer ties shall not be less in thickness than No. 9 gage wire and shall have a hook embedded in the mortar joint. Sheet metal ties shall not be less than No. 22 gage by 7/8" corrugated and fastened with 1 % galvanized roofing nails. Adjustable or strand wire veneer ties shall be used at CMU walls. 4. Unless otherwise noted on the plans, a steel angle L4x4xl/4 shall be used for supporting brick veneer over openings.s. This angle will not be required for arched windows where brick is self-supporting. length If theof the opening exceeds 6-0" then the steel angle shall be attached to the wood framing with %" x 3" lag screws @ 12" o.c. or Simpson Y4' x 3" SDS screws @ 12"o.c. WOOD FRAMING: 1. All wood framing has been designed in accordance with "National Design Specification (NDS) for Wood Construction," 2015 edition. 2. Southern Yellow Pine member design incorporates design values for all sizes and grades of visually graded Southern Yellow Pine dimension lumber per "Supplement No. 13 to the 2002 Standard Grading Rules for Southern Pine Lumber," published by the Southern Pine Inspection Bureau (SPIB). 3. All wood members exposed to weather or in contact with masonry, concrete or soil shall be treated with an appropriate preservative suitable for the exposure conditions. 4. If ACQ treatment is used on any wood member, then all nailing shall require hot -dipped galvanized nails meeting ASTM Al 53, Class C, or ASTM B695, Class 50. If borate treatment is used then galvanizing is not required. 5. Prefabricated wood trusses shall comply with NDS and "National Design Standard for Metal Plate Connected Wood Truss Construction (TPI 1-2014)." 6. All trusses shall be designed by the Truss Manufacturer's registered Engineer. 7. The Truss Manufacturer shall submit shop drawings and design notes with a registered Engineer's seal for approval. Design notes shall include the rated load capacity of the truss to truss connectors, and the manufacturer's license to fabricate trusses utilizing the connector system proposed. The contractor shall approve fabrication and installation drawings showing size, shape and layout. 8. Jobsite handling and erection, including temporary bracing, during installation of trusses shall comply with TPI / WTCA BCSI 1. 9. All prefabricated wood trusses subjected to uplift conditions shall be securely fastened to their supporting walls or beams with metal connectors as noted in the Truss Connection Schedule. 10. All gable ends shall be balloon framed or braced in accordance with the applicable detail as shown in the structural drawings. 11. Guardrails, handrails, and guard in -fill components (Balusters and Panel Fillers) shall be provided by others. 12. Engineered lumber (LVL, Parallam or LSL) shall meet the following minimum material specifications: LVL or Parallam LSL E=2,000,000 psi E=1,550,000 psi Fb=2,600 psi Fb=2,325 psi Fc =750 psi Fc =900 psi Fv=285 psi Fv=310 psi 13. Fasten plies of 1 3/" wide engineered lumber as follows: 2 -ply beams with ,, p y (3) rows of 0.131"x3 /< nails @ 12"o.c. 3 -ply beams with (3) rows of 0.131"x3'/d' nails @ 8"o.c. (each side) 4 -ply beams with (2) rows of Simpson 6 3/" long SDW screws @ 12" o.c. STRUCTURAL STEEL: 1. Structural steel shall conform to AISC Specifications for Design and Fabrication and Erection of Structural Steel for Buildings (latest editions). a. Welded Connections: AWS D1.1 b. Structural Steel plates: ASTM A36 (Fy=36 ksi) or ASTM A572 (Fy=50 ksi) c. Structural Steel W - shapes: = e s apes: ASTM A992 (Fy 50 ksi) d. Structural Steel Angles and Channels: ASTM A572 (Fy=50 ksi) e. Structural Steel Rectangular HSS or Tubes: ASTM A500 (Fy=50 ksi) f. Structural Steel Round HSS or Pipe: ASTM A500 (Fy=46 ksi) or ASTM A53F =35 ksi) ) 2. All structural steel connections and fabrications shall comply with AISC specifications. 3. Steel shop drawings shall be provided to the Engineer for approval prior to fabrication. 4. Holes required for bolted connections may be drilled or punched. Flame -cut holes shall not be used. 5. Bolts shall be installed to the "snug -tight" condition - u.o.n. 6. All structural steel shall be shop -painted with SSPC Paint 15 (red oxide) primer. Prior to painting, steelwork shall be cleaned per SSPC SP -6 "Commercial Blast Cleaning". 7. SSPC Paint 36 (polyurethane) shall be applied as the final coat to all structural steel surfaces exposed and visible to the exterior of the structure. 8. Field touch-up after installation where required to restore final finish. HARDWARE AND ANCHORS: 1. All framing anchors and connectors shall be manufactured by Simpson Strong -Tie, United Steel Products (USP), or Engineer approved equal. 2. All anchor bolts and threaded rods shall be in accordance with ASTM A307 or ASTM F1554, Grade 36. 3. All metal connectors and hardware which are exposed to the exterior or in contact with ACQ pressure treated lumber shall be Type 316 stainless steel or galvanized per ASTM Al 53, Class C, or ASTM 8695, Class 50. 4. Anchor adhesives shall be either SET -3G by Simpson Strong -Tie or HIT-HY 200 by Hilti with Florida Product Approval and installed according to the manufacturer's instructions. Holes shall be cleaned of all debris and brushed out prior to installation of anchor adhesive. ROOF COVERING: 1. The contractor shall be responsible for the design and installation of the roof covering system. 2. Asphalt shingles shall comply with ASTM D3161 and be installed according to the manufacturer's requirements. 3. Clay and tile roofs shall be installed per the "Concrete and Clay Roof Tile Installation Manual," and the manufacturer's requirements. i 4. Standing seam metal roofs shall comply with ASTM El 514 and be installed according to the manufacturer's requirements. 5. The contractor shall be responsible for the design and installation of all metal flashing and valley material. U C a� O E 0 19 i 0 s 3 L. CD U) a� s c • 00 U3 u N r-1 N M E J O n uL 0 W � CD J CD Z O w Y rn j U Cn Cn W N o = N Wlt W NC-) o r r Of N w o z0") O CD Z:) N Q to 00 0 OC! 0 d - O CDrn L 00 v FLORIDA C.A. NUMBER: 25846 0 v Tic D P -§NG��`0 FLOYD S. SIMPSON, PE FL PE No. 50791 m s Metal Connector Fastening Schedule Simpson ID FL # MITEK/USP ID FL # Fasteners Anchorage (U.O.N.) A35 10446.1 MPA1 17244.2,1. (12) 0.131" x 11/2" n/a ABU44 - Z 10860.4 PAU44 - TZ 17239.1311 (12) 0.162" x 21/2" or (12) 0.162" x 3Y2" 5/8" w/ 7" embed ABU66 - Z 10860.4 PAU66 - TZ 17239.1 ":> (12) 0.162" x 2Y2" or (12) 0.162" x 31/2" 5/8" w/ 7" embed CS16 10852.2 RS 150 17244.2' (11) 0.148" x 3" in each end - (22) total n/a DSP 10456.1 RSPT6-2 17244.29 (8) 0.148" x 11/2" into studs n/a (6) 0.148" x 1'/2" into double plate DTT2Z 10441.1 DTB-TZ 17219.1 (8) Y4" x 11/2" SDS Y2" w/ 4Y2" embed (mono) & 7" embed (stem) GBC 10861.3 HC520 N/A (5) 0.131" x 11/2" into gable brace n/a (7)0.131" x 2Y2" into double plate H2.5A 10456.3 n/a: use RT7 17236.1' (5) 0.131" x 2Y2" in each end - (10) total n/a H2.5T 10446.8 n/a: use RT7 17236.111 (5) 0.131" x 1 Y2" in each end - (10) total n/a H3 10456.3 RT3A 17236.1 1 (4) 0.131" x 2Y2" in each end - (8) total n/a H6 10456.3 LFTA6 17244.1'IT (8) 0.131" x 2Y2" in each end - (16) total n/a H8 10446.8 RT8A 17236.11 (5) 0.148" x 1'/2" in each end - (10) total n/a HDQ8 10441.3 n/a: use UPHD8 17219.6' (20)'/" x 3" SDS 7/8" w/ 12" embed HDL15 10441.4 PHD5 17219.4 (14) Y4" x 2Y2" SDS 5/8" w/ 7" embed (mono) & 12" embed (stem) HDU8 10441.4 PHD6 17219.4' (20) Y4" x 3" SDS 7/8" w/ 12" embed HETA16 14473.3 HTA16 17680.4' (10) 0.149'x 11/2" 4" embed HTS20/24/30 10456.6 HTW20/24/30 17244.81 (10) 0.148" x 3" in each end - (20) total n/a HTSM 16/20 11473.12 HTWM 16/20 6223.2 (8) 0.148" x 3" into wood n/a (4) %" x 2%" Titen into CMU (4) Y4' x 13/4" Titen into concrete HTT4 11496.6 HTT4 17324.2' (18) 0.162" x 21/2" 5/8" w/ 7" embed (mono) & 12" embed (stem) HTT5 11496.6 HTT5 17324.21 (26) 0.162" x 21/2" 5/8" w/ 7" embed (mono) & 12" embed (stem) LTP4 10446.13 MP4F 17244.24 (12) 0.131" x 1'/2" n/a LSTA18 10852.6 LSTA18 17244.1;8 (7) 0.148" x 3" in each end - (14) total n/a LTS12 10456.7 LTW12 17244.EI (6) 0.148" x 3" in each end - (12) total n/a MSTA24 10852.9 MSTA24 17244.118 (9) 0.148" x 3" in each end - (18) total n/a MSTAM24 11473.11 MSTAM24 17325.11 (9) 0.148" x 3" into wood n/a c NUMBER: 18-2176 1 COUNTY:DUVAL (5) Y4" x 2Y4 Titen into CMU WJOB (5) 1/4" x 13/4" Titen into concrete MSTA30 10852.9 MSTA30 17244. 118 (11) 0.148" x 3" in each end - (22) total n/a MSTA36 10852.9 MSTA36 17244. "18 (13) 0.148" x 3" in each end - (26) total n/a MSTAM36 11473.11 MSTAM36 17325.1 (13) 0.148" x 3" into wood n/a 01-17-19 (8) 1/4" x 2'/4" Titen into CMU c (8) %" x 13/4" Titen into concrete MTS12/20 10456.8 MTW12/20 17244.113 (7) 0.148" x 3" in each end - (14) total n/a MTSM16/20 11473.12 HTWM16/20 6223.2 (7) 0.148" x 3" into wood n/a (4) Y4" x 2'/4" Titan into CMU (4) W' x 13/4" Titan into concrete PA51 13326.4 TA51 N/A (14) 0.162" x 21/2" or (14) 0.162" x 3Y2" 4" embed SPH4/6 10456.12 SPTH4/6 17244.:32 (12) 0.148" x 1'/2" n/a SSP 10446.1 RSPT6 17244.,129 (4) 0.148" x 1'/" into studs n/a (3) 0.148" x 1Y2" into double plate STHD14 13326.7 STAD14 17230.13 (30) 0.148" x 3'/4" 14" embed Notes: 1.) Al connectors manufactured by Simpson Strong -Till; or MITEK/USP (U.O.N.) 2.) Mono = monolithic concrete; stem = masonrystem\vall or bond beam 3.) Anchorage refers to threaded anchors with noted diameters and embedment depths Clay Masonry (Brick): 1. Brick shall conform to ASTM C62, C216, or C652 for Building Brick, Facing Brick, and Hollow Brick, respectively. Grade MW shall be used. 2. Brick veneer shall be anchored with approved ties spaced no more than 16" o.c. vertical and 16" o.c. horizontal. Additional ties shall be provided around all wall openings greater than 16" in either direction, and shall be spaced no more than 36" o.c. and placed within 12" of the openings. 3. Strand wire veneer ties shall not be less in thickness than No. 9 gage wire and shall have a hook embedded in the mortar joint. Sheet metal ties shall not be less than No. 22 gage by 7/8" corrugated and fastened with 1 % galvanized roofing nails. Adjustable or strand wire veneer ties shall be used at CMU walls. 4. Unless otherwise noted on the plans, a steel angle L4x4xl/4 shall be used for supporting brick veneer over openings.s. This angle will not be required for arched windows where brick is self-supporting. length If theof the opening exceeds 6-0" then the steel angle shall be attached to the wood framing with %" x 3" lag screws @ 12" o.c. or Simpson Y4' x 3" SDS screws @ 12"o.c. WOOD FRAMING: 1. All wood framing has been designed in accordance with "National Design Specification (NDS) for Wood Construction," 2015 edition. 2. Southern Yellow Pine member design incorporates design values for all sizes and grades of visually graded Southern Yellow Pine dimension lumber per "Supplement No. 13 to the 2002 Standard Grading Rules for Southern Pine Lumber," published by the Southern Pine Inspection Bureau (SPIB). 3. All wood members exposed to weather or in contact with masonry, concrete or soil shall be treated with an appropriate preservative suitable for the exposure conditions. 4. If ACQ treatment is used on any wood member, then all nailing shall require hot -dipped galvanized nails meeting ASTM Al 53, Class C, or ASTM B695, Class 50. If borate treatment is used then galvanizing is not required. 5. Prefabricated wood trusses shall comply with NDS and "National Design Standard for Metal Plate Connected Wood Truss Construction (TPI 1-2014)." 6. All trusses shall be designed by the Truss Manufacturer's registered Engineer. 7. The Truss Manufacturer shall submit shop drawings and design notes with a registered Engineer's seal for approval. Design notes shall include the rated load capacity of the truss to truss connectors, and the manufacturer's license to fabricate trusses utilizing the connector system proposed. The contractor shall approve fabrication and installation drawings showing size, shape and layout. 8. Jobsite handling and erection, including temporary bracing, during installation of trusses shall comply with TPI / WTCA BCSI 1. 9. All prefabricated wood trusses subjected to uplift conditions shall be securely fastened to their supporting walls or beams with metal connectors as noted in the Truss Connection Schedule. 10. All gable ends shall be balloon framed or braced in accordance with the applicable detail as shown in the structural drawings. 11. Guardrails, handrails, and guard in -fill components (Balusters and Panel Fillers) shall be provided by others. 12. Engineered lumber (LVL, Parallam or LSL) shall meet the following minimum material specifications: LVL or Parallam LSL E=2,000,000 psi E=1,550,000 psi Fb=2,600 psi Fb=2,325 psi Fc =750 psi Fc =900 psi Fv=285 psi Fv=310 psi 13. Fasten plies of 1 3/" wide engineered lumber as follows: 2 -ply beams with ,, p y (3) rows of 0.131"x3 /< nails @ 12"o.c. 3 -ply beams with (3) rows of 0.131"x3'/d' nails @ 8"o.c. (each side) 4 -ply beams with (2) rows of Simpson 6 3/" long SDW screws @ 12" o.c. STRUCTURAL STEEL: 1. Structural steel shall conform to AISC Specifications for Design and Fabrication and Erection of Structural Steel for Buildings (latest editions). a. Welded Connections: AWS D1.1 b. Structural Steel plates: ASTM A36 (Fy=36 ksi) or ASTM A572 (Fy=50 ksi) c. Structural Steel W - shapes: = e s apes: ASTM A992 (Fy 50 ksi) d. Structural Steel Angles and Channels: ASTM A572 (Fy=50 ksi) e. Structural Steel Rectangular HSS or Tubes: ASTM A500 (Fy=50 ksi) f. Structural Steel Round HSS or Pipe: ASTM A500 (Fy=46 ksi) or ASTM A53F =35 ksi) ) 2. All structural steel connections and fabrications shall comply with AISC specifications. 3. Steel shop drawings shall be provided to the Engineer for approval prior to fabrication. 4. Holes required for bolted connections may be drilled or punched. Flame -cut holes shall not be used. 5. Bolts shall be installed to the "snug -tight" condition - u.o.n. 6. All structural steel shall be shop -painted with SSPC Paint 15 (red oxide) primer. Prior to painting, steelwork shall be cleaned per SSPC SP -6 "Commercial Blast Cleaning". 7. SSPC Paint 36 (polyurethane) shall be applied as the final coat to all structural steel surfaces exposed and visible to the exterior of the structure. 8. Field touch-up after installation where required to restore final finish. HARDWARE AND ANCHORS: 1. All framing anchors and connectors shall be manufactured by Simpson Strong -Tie, United Steel Products (USP), or Engineer approved equal. 2. All anchor bolts and threaded rods shall be in accordance with ASTM A307 or ASTM F1554, Grade 36. 3. All metal connectors and hardware which are exposed to the exterior or in contact with ACQ pressure treated lumber shall be Type 316 stainless steel or galvanized per ASTM Al 53, Class C, or ASTM 8695, Class 50. 4. Anchor adhesives shall be either SET -3G by Simpson Strong -Tie or HIT-HY 200 by Hilti with Florida Product Approval and installed according to the manufacturer's instructions. Holes shall be cleaned of all debris and brushed out prior to installation of anchor adhesive. ROOF COVERING: 1. The contractor shall be responsible for the design and installation of the roof covering system. 2. Asphalt shingles shall comply with ASTM D3161 and be installed according to the manufacturer's requirements. 3. Clay and tile roofs shall be installed per the "Concrete and Clay Roof Tile Installation Manual," and the manufacturer's requirements. i 4. Standing seam metal roofs shall comply with ASTM El 514 and be installed according to the manufacturer's requirements. 5. The contractor shall be responsible for the design and installation of all metal flashing and valley material. U C a� O E 0 19 i 0 s 3 L. CD U) a� s c • 00 U3 u N r-1 N M E J O n uL 0 W � CD J CD Z O w Y rn j U Cn Cn W N o = N Wlt W NC-) o r r Of N w o z0") O CD Z:) N Q to 00 0 OC! 0 d - O CDrn L 00 v FLORIDA C.A. NUMBER: 25846 0 v Tic D P -§NG��`0 FLOYD S. SIMPSON, PE FL PE No. 50791 a BY: CMF ED BY: FSS GENERAL NOTES _ ZHtt1: rn 0 N � m s 0 c Vca d 0- = o U ca LL1 Q c IW 0 E 0 LLJ U) 0 Z Q i CD a CO J N a N oo V c F- L1J Z LU -7) J 0 U d c NUMBER: 18-2176 1 COUNTY:DUVAL WJOB E' NTS a> DO NOT SCALE THIS DRAWING _ RELEASE DATE: 01-17-19 c a BY: CMF ED BY: FSS GENERAL NOTES _ ZHtt1: rn 0 N � STEMWALL FOUNDATION PLAN CJ = SUGGESTED CONTROL JOINT LOCATIONS (SEE DETAIL "T" ON SD -1) = DENOTES TWO STOR FOOTING CONDITION CONTRACTOR SHALL VERIFY ALL DIMENSIONS USING FINAL APPROVED FLOOR PLAN PRIOR TO CONSTRUCTION U C � % 1 O N C LLO W N CTM L CD J O LL U L1.1 � E J N o Z c O c o cn W N U 2-) � rTl < � Q- W N = O O O N rTl W � w W O I_- co 02 CL U) � N c=; N Z c) � LL Z:) T N (7 O OQ O 0 h 00 ClyOR Q d' T J O c Ocu rn Q T 00 � l• T cu _O CD N a FLORIDA C.A. NUMBER: 25846 0 cu a - * so x/91 Z PA7-E* = 3 nF CD FLOYD S. SIMPSON, PE cu E FL PE No. 50791 C OMMENTS: Cts C L O N O 0 O C Cts C N C/ CTS N Cn (U C CO to CCS N C L C= Q 1 (n v s •L 1 CU o = U W Q m W o E cm _ a 74 Lu — cn z Q z Q - U) a � - > O L 2 Q c 00 U a V c Z W 61—i O C) a� '= w JOB NUMBER: 18-2176 COUNTY: DUVAL =1'-0" (U,O.N.) N DO NOT SCALE THIS DRAWING O _ RELEASE DATE: 01-17-19 U C 1 BY: CMF-DJM ED BY: FSS FOUNDATION PLAN rnS�2 T 0 N