Loading...
1600 Selva Marina Drive 13-00003848 - NMV 4-Nw�1!'.M�'"arw aYt}rIM..bY ynl,.+A,T9NY+Y'.4+. �afy4tts,wrgpp„Wxp';..%N8%IS1fYMfPlf �.:.. — — .1 1 FILE copy General Contractors, Inc. • ° 248 Levy Rd. P.O. Box 330775 Atlantic Beach, FL 32233 (904)241-4416-(904) 241-4427fax TO: Jacksonville Fire & Rescue Dept. ATTN: Captain Bob Ratliff& Lt. Thomas Staples ADDRESS: 214 N. Hogan St. Rm 281 DATE: 05/21/14 CITY/STATE/ZIP: Jacksonville, FL 32202 REFERENCE/JOB: ABCC WE ARE SENDING YOU: ATTACHED X UNDER SEPARATE COVER VIA Courier Delivery - SHOP DRAWINGS - PRINTS X PLANS SAMPLES SPECIFICATIONS ❑ COPY OF LETTER X FOR APPROVAL COPIES DATE NO. DESCRIPTION 3 SK-1 Utility Wall Sketch, Signed &Sealed L6 Clubhouse Service Court&Screen Wall Plan AS1.00 Site Plan Release 3 Dear Capt. Ratliff and Lt. Staples: At the request of Mike Jones with the City of Atlantic Beach, please find the utility wall revision for the Atlantic Beach Country Club for your review and disposition. If you should need anything further, please don't hesitate to contact us 904-241-4416. Sincerely, Catherine Lewin RPC Design VX 904-241-4416 =RPC� General Contractors, Inc. 248 Levy Rd. P.O.Box 330775 (} Atlantic Beach, FL 32233 U (904)241-4416-(904)241-4427fax MAY 13 14 May 13, 2014 By Mike Jones City of Atlantic Beach Building Department 800 Seminole Rd. Atlantic Beach, FL 32233 RE: Atlantic Beach Country Club Utility Court Wall Permit Number: 13-00003848 Dear Mr.Jones: At the request of the owner, an 8' CMU utility court wall has been added to the service utility court of the above referenced project. A plan and structural section detail has been enclosed for review and approval. If you have any questions or comments, please feel free to contact me. Since ely, et J gues P sident C e -RP General Contractors, Inc. 248 Levy Rd. P.O.Box 330775 Atlantic Beach, FL 32233 (904)241-4416-(904)241-4427fax May 21 2014 u FILE Co PY :s v A . Lt.Thomas Staples Jacksonville Fire & Rescue Plan Review 214 N. Hogan St. STE 281 Jacksonville, FL 32202 RE: Atlantic Beach Country Club Utility Court Wall Revision Building Permit Number: 13-00003848 Dear Lt. Staples: At the request of the owner, an 8' CMU utility court wall has been added to the service utility court of the above referenced project. A plan and structural section detail has been enclosed for review and approval. If you have any questions or comments, please feel free to contact me. Sincere Peter rigues President Cc: file STATE OF FLORIDA COUNTY OF DUVAL The foregoing instrument was acknowledged before me this 21' of May, 2014 by d who is personally known to me or who has produced as identification. Notary Public,State of Florida o`'"Y 111,, �`iP`g' CATHERINE LEVAN Notary Public-State o1 Florida My Comm.Expires Apr 23.2017 �F OF 1 :•' Commission/FF 011275 v BUILDING INSPECTION DIVISION G vv�FloridaBim. REVISING ACTIVE PERMIT FORM DATE: 05/21/14 JOB NAME: ATLANTIC BEACH COUNTRY CLUB ADDRESS: 1600 SELVA MARINA DRIVE PERMIT NO: 13-00003848 (BUILDING PERMIT) CONTRACTOR: RPC GENERAL CONTRACTORS PHONE NO: 904-241-4416 FAX NO: 904-241-4427 ARCHTECT/ENGINEER PHONE NO: CLIFF DUCH 904-626-3452 FAX NO: BUILDING PLANS EXAMINER: MIKE JONES, CITY OF ATLANTIC BEACH REVISIONS FOR: COMMENTS PLEASE INDICATE BUILDING YES NO YES NO LANDSCAPE YES NO YES NO PLUMBING YES NO YES NO FIRE MARSHAL (g5) NO YES NO MECHANICAL YES NO YES NO ELECTRICAL YES NO YES NO SUBMITTED BY: CATHERINE LEWIN, RPC GENERAL CONTRACTORS 904-241-4416 CATHERINE@RPCGC.COM PLANNING and DEVELOPMENT DEPARTMENT 214 N.Hogan Street,Room 273 j Jacksonville,FL 32202 Phone:904.630.1100 Fax:904.255.8552 - www.coi.net R FILE COPY 8" U-BLOCK T/WALL, W/1-#4 CONT c SEE ARCHN � azo Q 8" CMu, A } SEE PLAN v o #6024" 00 o� DOWEL TO MATCH REINF. (LAP 4'-6" 00 /\�/ T/FTG EL, SEE PLAN 3-#5 CONT, w/ #4018" TRANSV. 3" CLR 3'-0" SECTION S3.1 SCALE: NTS Q':'••\GE�S••':�' No. %ST T0� JOB ...,r..•• G ' ALANTIC BEIVA �('E;,��� �L COUNTRY CLUB 11EN,.���'` McVEIGH & MANGUM JOB NO. SHT. NO. ENGINEERIN G•INC 13093 9133 R.G.Skinncr Purkwuy SK- 1 Jacksonville.Florida 32256 DATE Ph: (904)453-5200 (904)G3gu m 05/12/2014 ED 6330 email:mail@McMcVeighMnngum.com Eng.of Record:11.Cu iugton McVeigh Li-No.: 30692 1I—VIi-JJCity of Atlantic Beach APPLICATION NUMBER js Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 �I E-mail: building-dept@coab.us Date routed: (Q City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: f �a- /i QC i �j De artment review required Yes No Buildin Applicant: Planning &Zoning —�, Tree Administrator Project: Vf �jPublic Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 � RPC. General Contractors, Inc. n, i, nn 248 Levy Rd. P.O. Box 330775 J U N 0 4 2.014 Atlantic Beach, FL 32233 (904) 241-4416 - (904) 241-4427fax TO: City of Atlantic Beach ATTN: Shirley ADDRESS: 800 Seminole Rd. DATE: 06/04/14 CITY/STATE/ZIP: Atlantic Beach, FL 32233 REFERENCE/JOB: ABCC 013119 WE ARE SENDING YOU: ❑ATTACHED X UNDER SEPARATE COVER VIA Hand Delivery ❑ SHOP DRAWINGS ❑ PRINTS X PLANS SAMPLES SPECIFICATIONS ❑ COPY OF LETTER CHANGE ORD COPIES DATE NO. DESCRIPTION 3 1 ABCC Clubhouse Revision 3 Plans for Review 3 2 Revision 3 Narratives: 1 — General Contractor Narrative with Overall Changes 1 —Architect Narrative to COJ Fire Shirley, Please find ABCC Revision 3 plans and narrative. (2) Sets of these plans were also hand delivered to Capt. Bob Ratliff today by Pete Rodrigues. Thank you. Catherine Lewin Design Assistant -RP General Contractors, Inc. 248 Levy Rd. P.O.Box 330775 Atlantic Beach, FL 32233 (904)241-4416-(904)241-4427fax June 4, 2014 City of Atlantic Beach Building Department 800 Seminole Rd. Atlantic Beach, FL 32233 Attn: Mike Jones Re: Atlantic Beach Country Club—Revision 3 Permit# 13-00003848 Dear Mr.Jones: At the request of the client, the following changes have been made to the above mentioned project. 1. Revised Door CH43 of multi-purpose room (107) to 2-3080 doors (left-hand inswing & right-hand inswing). Revised Door CH41 of multi-purpose room (107)to 3080(left-hand outswing). Revised door schedule. 2. Added sheet A1.11A, Detail 1 to show dimensioning of windows at Grill (121). Revised size of windows to 5'- 6"x6'-8" (store front glass). 3. Revised room names to show L-shaped office (201) on second floor. Room (202) not used. Revised square footage table as per new designation. These changes have been clouded and marked as Revision 3. Please feel free to contact me if there are any questions or comments. Respectf y JUN 04 2014 Peter d ' es President Py — RPC General Contractor's 1 From:9047371099 11/04/2014 13:02 #798 P-002/003 l EARLY PONVER AGREEMENT & RELEASE CITY OF ATLANTIC BEACH ter.S e Electric power is requested now under the conditions and terms of this fully executed Agreement&Release Job Address: i COW 5�COQ RAGLIC t Ana t>�e +EoA Permit No. 13 c p Service Type(Circle One): Overhead nderground We,the undersigned General Contractor and Electrician,understand and agree: 1. "Early Powe' is purely for our construction convenience, it is not required by Codes and does not substitute for Final Inspections or the C/O(Certificate of OccupancyjfFiat must be issued bet'ore occupancy, and as such is at the discretion of the Building Official. 2. The City of Atlantic Beach will make a special inspection prior tothe early power energizing. All rough inspections must have prior Approval,including meter base connections. 3. Occupancy or use of the new construction before a formal CIO constitutes fraudulent use of the early electric service. Such action is expressly prohibited and penalized by The City of Atlantic Beach Ordinances. A violation of this Agreement shall result in a request for prompt removal of electric service after a twenty-four hour notice. 4. "Early Power"release authority is the Electrician and/or the Contractor and must not occur before: a. Equipment,devices and fixtures are installed(or blanked off)safely. b. Panel is complete with breakers and cover,and(labeling required at final inspection). c. Service connection and grounding is complete. d- The electric system has safely passed through electrical check. e. Meter can is permanently marked with address. f. Temporary address numbers displayed(Permanent numbers are required for C/O). 5. This fully completed form is to be submitted to the Building Department by hand,mail or fax. 6. Future such Agreements will not be accepted from those who violate any one of the above items. CONTRACTOR �jj DATE PRINT NAME r, P—oB F 1$r (,€ Gm/trt A 9rt/.tom th, ?fivr�P-+'F e w r. ELECTRICIAN �� `�, L���— -- DATE 4 PRINT NAME _-- 800 Seminole Road,Atlantic Beach FL 32233 Phone:(904)247-5826 Fr (904)247-5845 hitp:i'wwx.coab.us revised 01 30 09 10 A CRONK D u c H A R C H f T E C T U R E May 28, 2014 Capt. Bob Ratliff Jacksonville Fire& Rescue Department Fire Prevention Division Office of Plan Review 214 N. Hogan Street, Room 281 Jacksonville, FL 32202 Re: Atlantic Beach Country Club–Plan Revisions Permit#13-00003848 Dear Capt. Ratliff: At the request of the client,the following changes have been made to the above mentioned project. ARCHITECTUAL REVISIONS: Attached associated drawings. 1. Multipurpose room (107). Modified Doors see attached. 2. Revised attic area to show stair&landing(200)&Accounting office&storage(202). a. This modification is supported by table 1004.1.1–Less than 500 sf b. Single exit 1021.2&Table 1021.2 c. No Elevator and ADA Accessibility–553.509 Vertical Accessibility Exception (1) (C) . i. Less than five occupants ii. Not open to the public 553.509 Vertical accessibility.— (1)This part and the Americans with Disabilities Act Standards for Accessible Design do not relieve the owner of any building,structure, or facility governed by this part from the duty to provide vertical accessibility to all levels above and below the occupiable grade level, regardless of whether the standards require an elevator to be installed in such building, structure,or facility,except for: (c) Occupiable spaces and rooms that are not open to the public and that house no more than five persons, including, but not limited to, equipment control rooms and projection booths. 1 These changes have been clouded and marked as Revision 3. Please feel free to contact me if there are any questions or comments. Respect ITIS,. J. p Cliffor uch, ICAA�A. .A.#AR 14227 Q6ok Duch Architecture. 904=.626-34F' _ 3 2 J CRONK ARCH1TECTURE May 28, 2014 Capt. Bob Ratliff Jacksonville Fire& Rescue Department Fire Prevention Division Office of Plan Review 214 N. Hogan Street, Room 281 Jacksonville, FL 32202 Re: Atlantic Beach Country Club–Plan Revisions Permit#13-00003848 Dear Capt. Ratliff: At the request of the client,the following changes have been made to the above mentioned project. ARCHITECTUAL REVISIONS: Attached associated drawings. 1. Multipurpose room (107). Modified Doors see attached. 2. Revised attic area to show stair&landing(200)&Accounting office&storage(202). a. This modification is supported by table 1004.1.1–Less than 500 sf b. Single exit 1021.2&Table 1021.2 c. No Elevator and ADA Accessibility–553.509 Vertical Accessibility Exception (1) (C) . i. Less than five occupants ii. Not open to the public 553.509 Vertical accessibility.— (1)This part and the Americans with Disabilities Act Standards for Accessible Design do not relieve the owner of any building,structure,or facility governed by this part from the duty to provide vertical accessibility to all levels above and below the occupiable grade level, regardless of whether the standards require an elevator to be installed in such building,structure, or facility,except for: (c) Occupiable spaces and rooms that are not open to the public and that house no more than five persons, including, but not limited to, equipment control rooms and projection booths. ` r•. G0 o ` 0 ji 1 r These changes have been clouded and marked as Revision 3. Please feel free to contact me if there are any questions or comments. Res.pectfjrJ ;, C CIJ uch, ICAA,�A. :A.#AR 14227 06tik Ouch Architecture. -9Q#,626-3452 r '` pQ'S c 4pc 2 LETTER OF TRANSMITTAL General Contractors, Inc. 248 LEVY ROAD / P.O. Box 330775 AiLAN11C BEACH, FLORIDA 32233 (904) 241-4416 / fAX (904) 241-4427 COMPANY: City of Atlantic Beach ATTENTION: Shirley Graham&Dan Arlington ADDRESS: 800 Seminole Rd. DATE: 10/14/14 CITY/STATE/ZIP: Atlantic Beach,FL 32233 REFERENCE/JOB: Atlantic Beach Country Club PHONE: (904)247-5826 JOB#: 013119 WE ARE SENDING YOU: ® ATTACHED ❑UNDER SEPARATE COVER VIA Hand Delivery by Cat THE FOLLOWING ITEMS: ❑SHOP DRAWINGS ®PRINTS ❑SAMPLES ❑SPECIFICATIONS ❑COPY OF LETTER CHANGE ORDER ❑ OTHER COPIES DATE DESCRIPTION Atlantic Beach Country Club Full Complete Set of Building Plans 5 Revisions 5,7&8 for plan review c Narrative from Cronk Duch Architecture dated 10/14/14 THESE ARE TRANSMITTED AS CHECKED BELOW: ❑ FOR APPROVAL ❑APPROVED AS SUBMITTED ❑RESUBMIT_COPIES FOR APPROVAL ® FOR YOUR USE ❑APPROVED ❑SUBMIT_COPIES FOR DISTRIBUTION ❑ AS REQUESTED ❑RETURN_CORRECTED PRINTS ❑ FOR REVIEW AND COMMENT Remarks: 3 copies for City of Atlantic Beach 2 copies for Jacksonville Fire Shirley—Plan revisions for review. Please send 2 copies over to Fire for review. Let me know if you need anything further. Thank you, Catherine SIGNED: Catherine Lewin Project Coordinator Copy to File. jr CRONK D U C H A R C H I T E C T U R E October 14, 2014 City of Atlantic Beach Building Department 800 Seminole Rd. Atlantic Beach,FL 32233 Attn: Dan Arlington RE: BUILDING PERMIT B-14-00003848 Atlantic Beach Country Club 1600 Selva Marina Blvd. Atlantic Beach, FL 32233 Dear Mr. Arlington, Below is a comprehensive list of changes post permit set. REVISION#6—Owner Revisions, Mechanical, Electrical and Plumbing updates. 1. Revisions as per owners updates. Refer to Mechanical, Electrical and Plumbing for this revision#6 set. The architectural series of sheets is used for reference and to show continuity of templates. See attached narrative dated 10/13/14 from McVeigh& Mangum Engineering. REVISION#7—ADA Building Code Requirements and Owner Revisions. 1. All restroom access as per owner changes and ADA building code requirements. 2. Added lockers to men's tennis restroom (152) and women's tennis restroom. REVISION#8—Revisions as per field conditions. 1. Revised restrooms and shower as per field measurements; restrooms, door swings, wall locations,room access, etc. 2. Revised Bar 120 equipment as per Owner changes. 3. Revised Kitchen 111 equipment as per Owner changes. If you have any questions,please feel free to contact me. Respectfully, CLIFF DUCH CRONK DUCH ARCHITECTURE MCVEIGH&MANGUM E N G I N E E R I N G - I N C October 13,2014 City of Atlantic Beach Building Department 800 Seminole Rd. Atlantic Beach,FL 32233 Attn: Dan Arlington Re: BUILDING PERMIT B-14-00003848 Atlantic Beach Country Club 1600 Selva Marina Blvd. Atlantic Beach,FL 32233 Dear Mr. Arlington, Below is a list of MEP changes to previously approved plans, included in Revisions#6 thru #8 issued for this project: Sheet MO.1 Exhaust Fan Schedule revised for changes in restrooms,per ADA Revisions Sheets M1.1,M1.2 Supply and exhaust duct work revised for changes in restrooms,per ADA Revisions Sheet P0.1 Plumbing Fixture Demand Tabulation and Plumbing Fixture Schedule revised to coordinate with changes in restrooms,per ADA Revisions Sheet P 1.1 Gas connections and coordinating pipe add/changed per owner's comments. Sheets P2.1,P2.3,P3.1,P3.2 Sanitary plans revised for changes in restrooms,per ADA Revisions Sheets P2.2,P2.4,P3.4,P3.5 Domestic water plans revised for changes in restrooms,per ADA Revisions Sheets P2.2,P3.3 Domestic Water and Gas plans revised to coordinate with owner directed kitchen equipment changes Sheet E1.0 Added one light pole and relocated one light pole STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL BUILDING PERMIT B-14-00003848 Atlantic Beach Country Club October 13,2014 Page 2 of 2 Sheet E1.1 Revised to coordinate with locker and restroom ADA revisions Sheet E1.2 Revised to coordinate with owner directed kitchen equipment changes Sheet E2.1 Revised coordinate with locker and restroom ADA revisions Please let me know if you have additional questions or if I can help further. Sincerely, Wayne D.Mangum,P.E.,President C R 0 N K - SUCH A R C H I T E C T U R E AUGUST 8, 2014 1 RE: BUILDING PERMIT B-14-00003848 ATLANTIC BEACH COUNTRY CLUB 1600 SELVA MARINE BLVD. rAUG ATLANTIC BEACH, FL 12 2014 DAN ARLINGTON, By__ BELOW IS A COMPREHENSIVE LIST OF THE REVIONS POST PERMIT SET. REVISION#4 - REFLECTED CEILING PLAN CHANGES (AS PER OWNER COMMENTS) AS OF: MAY 5,2014 1. REVISED REFLECTED CEILING PLAN AS PER OWNER COMMENTS REVISION#4.1 -OWNER PLAN REVISIONS AS OF: MAY 22, 2014 1. REVISED MEN'S LOCKER'S (127), BAR (120),RESTROOM FOYER(139), LIQUOR STORAGE/COOLER(120A), &KITCHEN (I 11) EQUIPMENT AS PER OWNERS COMMENTS. MEN'S LOCKER'S (127) ENLARGED USING OFFICE SPACE. GENERAL MANAGER'S OFFICE MOVED TO SECOND FLOOR. 2. REVISED DOOR ASSEMBLY/ SWING AS PER OWNERS COMMENTS. 3. REVISED REFLECTED CEILING PLAN AS PER TELEPHONE CONFERENCE. REVISION#5 - REVISED SECOND FLOOR PLAN (AS PER OWNERS COMMENTS) AS OF: JUNE 5, 2014 1 1. REVISED SECOND FLOOR PLAN AS PER OWNERS COMMENTS. REVISION#5.1 -CORRECTIONS (AS PER OWNERS COMMENTS) AS OF: JUNE 18, 2014 1. CHANGED SWING OF DOOR CH3A OF GOLF PRO SHOP (122). REPLACED WESTERN-MOST WINDOW OF MEN'S LOCKERS (127)W/DOOR CH3. REPLACED ORIGINAL POSITION OF CH3, EASTERN-MOST POSITION W/C3 WINDOW. REMOVED COMMON WALL BETWEEN WOMEN'S PRIVATE VESTIBULE (129) AND SHOE SHINE AREA (129A). REMOVED DOOR CH22A. RENAMED ROOM 129 TO PRIVATE VESTIBULE. REVISED DOOR CH23 TO 2680. REVISED DOOR&WINDOW SCHEDULES. 2. ADDED DOOR CH15A TO CHASE IN RESTROOM FOYER(139). CHANGED POCKET DOOR CH29 TO CASED OPENING 4080. 3. REVISED DOOR CH8 TO SHOW 2 OPERABLE 'FRENCH DOORS'W/ 1 FIXED. 4. REVISED SWING OF DOOR CH41 OF MULTI-PURPOSE ROOM(107) 5. REVISED DOORS CH31 - CH35 TO SHOW CASED OPENINGS (SEE LOCATIONS FOR WIDTHS. ALL OPENINGS HAVE CHANGED TO 9'-0" HEADER HT. REVISED DOOR SCHEDULE. 6. REVISED CHAMFERED CORNERS OF FLAT ROOF/MEZZANINE ABOVE KITCHEN (111). ADDED 3-3050 SHUTTERS TO NORTH FASCADE. 7. REVISED DOORS T4 (MEN'S TENNIS R.R. - 152) &T3 (WOMEN'S TENNIS RESTROOM - 153) TO SHOW HALF GLASS DOORS. REVISED DOOR SCHEDULE. 8. ADDED 6040 WINDOW TO NORTH WALL OF GENERAL MANAGER'S OFFICE (201). REVISED WINDOW SCHEDULE. 9. REVISED BEVERAGES (119A) &EQUIPMENT IN KITCHEN (111). 10. REVISED EQUIPMENT IN BAR(120). 11. REDUCED PLATE HEIGHT OF DELIVERY ENTRY (002) &FOOD & BEVERAGES WINDOW (005) BY F-2" (VERTICAL DIMENSION) 12. ADDED AWNING/COVER&COLUMNS TO DINING PATIO (006). REVISED 2 GRILL(121) WINDOWS TO SHOW PANELS BELOW. 13. REVISED DINING HALL(119) CLERESTORY/DORMERS TO SHOW WOOD SURROUND. REMOVED ALL SECONDARY BEAMS REMOVED. REMOVED ALL DINING LOGGIA(116) BEAMS &WOOD CEILING FINISH. REPLACED W/ GYP. BD. 14. REVISED LIFE SAFETY PLAN 15. REVISED GABLE END ROOF AT RECEPTION (150) TO SHORTER OVERHANG. 16. REVISED CEILING HEIGHTS ACCORDING TO TELECONFERENCE W/OWNER. REVISION#6 - OWNER REVISIONS - MECHANICAL, ELECTRICAL & PLUMBING UPDATES AS OF: JULY 28, 2014 1. REVISIONS AS PER OWNER'S UPDATES. REFER TO MECHANICAL, ELECTRICAL&PLUMBING FOR THIS REVISION#6 SET. THE ARCHITECTURAL SERIES OF SHEETS IS USED FOR REFERENCE &TO SHOW CONTINUITY OF TEMPLATES. IF YOU HAVE ANY QUESTIONS OR NEED CLARIFIATION, PLEASE CONTACT ME. RESPECTFULLY, CLIFF DUCH CRONK DUCH ARCHITECTURE 3 CRONK UCC AHI A R C H I T E C T U R E October 28, 2014 City of Atlantic Beach Building Department 800 Seminole Rd. Atlantic Beach, FL 32233 Attn: Dan Arlington RE: BUILDING PERMIT B-14-00003848 Atlantic Beach Country Club 1600 Selva Marina Blvd. Atlantic Beach, FL 32233 Dear Mr. Arlington, Below is a list of owner requested life safety changes. REVISION#9—Owner revisions to life safety plan &related items. 1. Revised select items on life safety plan as per redline set. a. Edited exercise room occupancy number. b. Removed exit light on south wall of dining hall (119) door#CH46. c. Removed egress notation and exit light on north and west exits of kitchen (111) door #CH 12/door#CH 11. d. Added exit light south wall of kitchen (111) door to dining loggia(116)door#CH36. e. Removed exit light on west wall of golf pro shop (122) door#CH4. f. Added pull station to women's private vestibule(129)door#CH2. g. Removed egress notation and exit light on west wall of exercise room (154) door#T12. h. Added exit light to south wall of multipurpose room (107) door#CH43. i. Added pull station on east wall of exercise room (154). j. Edited size of pull station in men's lockers (13 0) door#CH3. 2. Added notation regarding"This Door Must Remain Unlocked While Occupied". 3. Added multi-purpose room (107) occupancy notation. Added column to area and occupancy calculation table for multi-purpose room. If you have any questions,please feel free to contact me. Respectfully, CLIFF DUCH CRONK DUCH ARCHITECTURE G� C)J C R O O K . -& D U C ]H[ ARCHITECTURE November 18,2014 City of Atlantic Beach Building Plan Review 800 Seminole Road Atlantic Beach,FL 32233 Attn:Mr.Dan Arlington Re: Atlantic Beach Country Club Dear Mr.Arlington: The following are our responses to plan review comment email dated 11/17/14. All plan sheets that required revisions per the following comments have been included with this re-submission. Comment: 1. Let's talk about the mezzanine. It seems to have grown into a story with the possibility of numerous people(more than 5). It started out as an office with maybe an assistant(2 people). The latest plan now includes security and accounting. Please review the 2012 FAC,Section 201. To accept this plan,I will need a floor plan showing specific work areas for less than 5 people and a statement that less than 5 people will occupy these spaces in the future. I do not think that 201(3)refers to offices,but it is not clear enough to prohibit. Response: CDA : Have Complied See attached drawings. Comment: 2. Thermal barrier over spray foam. Some of the section drawings still indicate a spray-on thermal barrier, but I am pretty sure that it was not applied. It was only applied,I believe in,one location. Can we get a letter describing the attic insulation on this project? The letter can be some expanded language,based on the attic cards that should be posted at each attic access. Please review FBC-EC, Section 303.1. At the final inspection,we will check that the attic areas with the spray-on thermal barrier are sealed off from the unprotected areas. Response: CDA:Have Complied,See attached drawings. Comment: 3. Did the storage area over the kitchen expand? If so, is the area protected with the thermal barrier still intact? Response: RPC Response:No. This area over the kitchen has remained the same size since the building was framed and the thermal barrier DC315 spray was applied. Again this area is also not a storage area. It is just dead space from the tall trusses that can be accessed for maintenance purposes only. For example:(Hood and Duct Cleaning). Respectfully, CliffDuchc n Cronk Duecture Nj' E rB CERTIFIED TEST, ADJUST AND BALANCE REPORT DATE: 12/5/2014 PROJECT Atlantic Beach CountryClub ADDRESS Atlantic Beach, Florida ARCHITECT Cronk Duch Architecture ENGINEER McVeigh & Mangum Engineering, Inc. HVAC CONTRACTOR Weather Engineers t4 � yG HOLISTIC TEST & BALANCE - 3614 LENOX AVE. JACKSONVILLE, FL 32254 2101 (904) 900-1484 3*1115 LOYD E. UFFELMAN -� % 7 HOLISTIC TEST & BALANCE PROJECT: Atlantic Beach Country Club 12/l/2014 LOCATION: Atlantic Beach, Florida FAN TEST SHEET SPECIFIED FAN# KEF-1 FAN# KEF-2 FAN# KEF-3 FAN# MUA-4 LOCATION Dishwasher Kitchen Hood Kitchen Hood Kitchen TOTAL CFM 975 2979 2208 4149 FAN RPM 1489 829 1150 520 TOTAL SP 0.7 1.2 1.1 0.75 MOTOR HP 0.5 1.5 1.0 1.5 TEST MANUFACTURER Captive Aire Captive Aire Captive Aire Captive Aire MODEL # NCA8FA NCA24HPFA NCA16HPFA A3-G18 SERIAL MOTOR MFG WEG WEG WEG WEY MOTOR HP .50 1.5 1.0 1 1/2 MOTOR RPM 1730 1720 1730 1720 MOTOR VOLTS 115/1 v 208/3v 208/3v 208/3v MOTOR F.L.A. 7.7 4.7 3.3 4.7 RUN AMPS 4.3. 4.0, 4.3 2.7, 2.9, 2.6 4.0, 3.6, 3.7 H .SIZE/RTG LINE VOLTAGE 210/3v 210/3v 210/3v TOTAL CFM 3050 2268 3990 FAN RPM 867 1093 527 TOTAL S.P. 1.19 1.03 0.72 NOTES: * Dishwasher hood not running (KEF-1) HOLISTIC TEST & BALANCE DUCT TRAVERSE SHEET ZONE TOTALS DATE: 12/3/2014 PROJECT: Atlantic Beach Country Club LOCATION: Atlantic Beach, Florida TRAVERSE DUCT REQSH!!FINAL SIZE AREA SYSTEM LOCATION VEL EL CFMKEF-1 Kitchen 10" 0.55 886 KEF-1 Kitchen 10" 0.55 886 487.5 KEF-2 Kitchen 28"x10" 1.9 1568 2979 1605 3050 KEF-3 Kitchen 20"x10" 1.4 1577T2208 1620 2268 MUA-4 Kitchen 108"x14" 10.5 3954149 380 3990 REMARKS: CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD a x ATLANTIC BEACH, FL 32233 b L E �' INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003848 Date 2/10/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description COMMERCIAL NEW CONSTRUCTION Property Zoning . . . . . . . TO BE UPDATED ----Application valuation-_ . .SCAy_-'--- 5732911 ��], Application desc ������ � ?i NEW AB/SELVA CC BUILDING ---------------------------------------------------------------------------- Owner Contractor--- ---- ------ SELVA MARINA COUNTRY- �- E COPY RPC GENERAL CONTRACTORS 1600 SELVA MARINA DR 248 LEVY RD ATLANTIC BEACH FL 322335616 ATLANTIC BEACH FL 32233 (904) 241-4416 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . ASSEMBLY Flood Zone . . . . . . . . ZONE AE ----------------- ----------------------------------------------------------- Permit . . . . . . COMMERCIAL NEW Additional desc . . Permit Fee . . . . 12146 . 00 Plan Check Fee 6073 . 00 Issue Date . . . . Valuation . . . . 5732911 Expiration Date . . 8/09/14 ---------------------------------------------------------------------------- Special Notes and Comments Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible . 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION C 2008 NATIONAL ELECTRIC CODE ' ED Ensure all meter boxes, sewer cleanouts and valve coversi are set to grade and visible . A sewer cleanout must be installed at the property line . Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible . *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: 6�A �D *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS ---------------------------------------------------------------------------- PERMIT Qtr OV1FftibRLV IN ACCORDANCE WITH AcLL-CIT1SJNTA,.A"1t�-B�R4C qFNCES AND THE FL4ARAc 19 BUILDING CODES. CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 13-00003848 Date 2/10/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DEV REVIEW-COMMERCIAL/IND 100 . 00 STATE DBPR SURCHARGE 182 . 19 UTIL REV COMMERCIAL BLDG 75 . 00 WATER CROSS CONNECTION 200 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 12146 . 00 12146 . 00 . 00 . 00 Plan Check Total 6073 . 00 6073 . 00 . 00 . 00 Other Fee Total 739 . 38 739 . 38 . 00 . 00 Grand Total 18958 . 38 18958 . 38 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD !J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003848 Date 2/18/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description COMMERCIAL NEW CONSTRUCTION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 5732911 ---------------------- ------------------------------------------------------ Application desc NEW AB/SELVA CC BUILDING ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SELVA MARINA COUNTRY CLUB RPC GENERAL CONTRACTORS 1600 SELVA MARINA DR 248 LEVY RD ATLANTIC BEACH FL 322335616 ATLANTIC BEACH FL 32233 (904) 241-4416 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . ASSEMBLY Flood Zone . . . . . . . . ZONE AE ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc INSTALL 80 FIXTURES Sub Contractor AMERICAN PLUMBING CONTRACTORS Permit Fee . . . . 615 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/17/14 ---------------------------------------------------- ------------------------ Special Notes and Comments Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE 2008 NATIONAL ELECTRIC CODE Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible . A sewer cleanout must be installed at the property line . Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible . *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS PERMFF-IS APPR0VED-W+L-N'1N-ACf1Mt3ANer—i'n,H-At t i3E-AcFI-ORD1N7tlQCES ANI3 Tf1E FCORT6A------- BUIL°IN(UL( `r Fees . . . . . . . . . STATE PLBG DCA SURCHARGE 9 . 23 'S t CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J F ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 13-00003848 Date 2/18/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE PLBG DBPR SURCHARGE 9 . 23 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 615 . 00 615 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 18 .46 18 . 46 . 00 . 00 Grand Total 633 .46 633 .46 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION Z b CITY OF ATLANTIC BEACHG 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: _ 1r/pUU V4S fnfi A PERM4�• 3 NEW OR REPLACEMENT INSTALLATION: Project Value$ TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory _�_ Water Heater Other Fixtures fi/q,N� Water Treating System RE-PIPE: S 4� TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well **SJR WD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.** ❑ Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Ut} LIU -1Phone Number Plumbing Company iRiCl Nu"7(L?l 0� Office �/,6 Fax Co. Address:57-2.26 A 1.1 7 City �?f4 b Staten. 7.i p _,2'a// License Holder(Print):A/" State Certific ,� ""^�Vegistration# CU Notarized Signature of Lic e Holder h' NL4L -7 `L SI Q 25—Q JENNIFER AVER Befor is y of 20 ,A ••' +, +: MY COMMISSI N#FF 01 1480 EXPIRES: Signat of Notary Public o�F�°,•` Bonded Thru Notary Public Underwrlens � Jv� CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Jlilt Application Number . . . . . 14-00000223 Date 2/18/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description PLUMBING ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 --------------------- ------------------------------------------------------- Application desc PLUMBING FOR FITNESS CENTER ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SELVA MARINA COUNTRY CLUB AMERICAN PLUMBING CONTRACTORS 1600 SELVA MARINA DR 5720 ARLINGTON RD ATLANTIC BEACH FL 322335616 JACKSONVILLE FL 32211 (904) 591-5380 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . INSTALL 51 FIXTURES Permit Fee . . . . 412 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/17/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE PLBG DCA SURCHARGE 6 . 18 STATE PLBG DBPR SURCHARGE 6 . 18 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 412 . 00 412 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 12 . 36 12 . 36 . 00 . 00 Grand Total 424 . 36 424 . 36 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: 1y0 t PERMIT it NEW OR REPLACEMENT INSTALLATION: Project Value$ TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Z Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System RE-PIPE: TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan S Drinking Fountain Slop Sink l Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well ** SJR WD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.** ❑ Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other law regulation construction or the performance of construction. Property Owners Name / u wd L one Number Plumbing Company 'C/4'*V Z nn 0 ffice Phone 7 - S Fax 95� Co. Address: 14t kr* °N City State Vt_Zip r3 License Holder(Print): L� C State Cert' ation/Registration# Notarized Signature of Licen e der JENNIFER WALKER Before m thl of 5ae 20 +, MY COMMISSION#FF 011490 =;. EXPIRES Apra^ t, a Public oo i Bonded Thru Notary Pud c Undemiters -- AMMS Viewer Page 1 of 1 Id • I � IIS �� �—�---�� � �� r — --, ti 0.2 PCT ANNUAL CHANCE FLOOD HAZARD r----ITNKSIDE Lr ' ' .I,I•� '4 y ��t 1y'' ti� - Yeti��I ti�,tiSti--r--- -� " ��� -71 Fj �_,�,i'I� by '��._�_--���.,,y�� ,r � •,�,� '�._�— CKydgMjC)20DSCky�f I I Al FEB 1 X 2014 •. _ No 4 TTA , _ * � 1ACVEIGH GUM -o•t STATE OF DENG I N E E R I N G • INC -�••'• FEB 1 2014 THRESHOLD BUILDING a�NA�L��EN,��``'''� STRUCTURAL OBSERVATION PLAN 'By Atlantic Beach Country Club Atlantic Beach,FL 1. SUMMARY A. In compliance with Florida Statues, the Owner will employ a Special Inspector registered in the State of Florida to observe construction of the structural components of the Atlantic Beach Country Club. The project consists of two-story country club. 2. RESPONSIBILITIES OF 1E SPECIAL INSPECTOR A. The Special Inspector will be responsible to the enforcement agency and will report his observation results in accordance with current governing Florida statutes. B. The Special Inspector i% responsible for observing that the construction of the structural system complies with the Official Conypet Documents. Official Contract Documents are defined as the permitted plans, addenda,and the specify;alions with all amendments thereto,and this Structural Observation Plan. C. The Special Inspector may use a representative to perform the work. The Special Inspector utilizing Authorized Representatives shall insure the Authorized Representative is qualified by education or licensure to perform the duties assigned the Special Inspector. The qualifications shall include licensure as a Professional Engineer or Architect; graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;or registration as building inspector or general Contractor. The use of a representative shall be in compliance with Florida Statutes. The Special Inspector shall be in responsible charge of the work of the Authorized Representative, including reviewing reports and spot checks. The Special Inspector must pt—onally visit the site at points during construction which he deems key to the inspection program. D. The Special Inspector - his Authorized Representative will visit the project site as required by the construction activity to observe the various structural elements during the progress of the work E. The Special Inspector il' report observations of materials,workmanship or other features of construction deviating from the reqs • ..nents of the official contract documents. Guidelines for observations covering specific areas of constru on are listed herein. F. Quality control inspects ,,,s and testing by an independent testing laboratory are required by the project specifications for some -}ructural elements and will be available to the Special Inspector to supplement his own observations.Thes: eports may include,but are not limited to;soil testing,concrete testing and steel connection testing. G. The acceptance of any structural component by the Special Inspector in no way relieves the Contractor of responsibility for complying with the requirements of the contract documents. H. Neither the Special Inspector nor his Authorized Representative shall make any design decisions or direct the Contractor to deviate from the approved contract documents. Any deviation from the approved contract documents shall be brought to the attention of the Contractor in a timely manner,so as to avert any undue STRUCTURAL • MECHA' • ELECTRICAL • PLUMBING - FIRE PROTECTION • TECHNOLOGY W.Skinner Parkway • Jacksonville,Florida 32256 (904) i200 • Fax(904)636-6770 • mail@mcveighmangum.com T i MCVEIGH&.MANGUM E N G I N E E R I N G - I N C expenses. If the Contractor corrects any deviation to the satisfaction of the Special Inspector, no further action is necessary. If the deviations are not corrected to the satisfaction of the Special Inspector,they shall be brought to the attention of the Structural Engineer of Record and the enforcing agency. I. The Special Inspector shall institute quality assurance procedures to include,but not be limited to,requiring unscheduled visits, utilization of relevant check lists, use of a Site Visit Report and insuring that the Inspector or the Authorized Representative is at the project whenever so required by this plan. i J. The Special Inspector will maintain a written record of threshold building observation activities and will render signed and sealed reports promptly to the Building Official with copies to the Owner,Architect of Record,Structural Engineer of Record and the Contractor. Individual reports may include any or all of the following: 1. General report on construction progress. 2. Weather conditions. 3. Other personnel present during the site visit. 4. Detailed check-off reports on specific areas. 5. Reports of the corrections of deficiencies previously noted. 6. Special test reports,welders'certification,sketches or other supplemental data. K. In addition to the report content requirements noted in section J, reports shall comply with any specific submission requirements, where applicable, of the City/County, or any other authority having local jurisdiction. L. At the completion of all structural work and after the correction of all deficiencies,the Special Inspector shall submit a signed and sealed statement to the Building Official conforming to Section 553.79 Subsection 7(a)Florida Statues. Copies will be sent to the Owner,Architect of Record,Structural Engineer of Record,and Contractor. M. This plan allows for general and specific items of concern. It does not limit the Special Inspector to only items listed. The Special Inspector's judgment must prevail on items not specifically covered. 3. RESPONSIBILITIES OF TIDE CONTRACTOR A. The Contractor shall furnish the Special Inspector, and keep current, a schedule of construction. The Contractor shall notify the Special Inspector 24 hours prior to the need for a site visit. The Contractor shall not place concrete or;_W any work needing observation prior to observation by the Special Inspector. The Contractor shall make all areas available and safe for observation. B. The Contractor shall furnish all relevant test reports to the Special Inspector. These reports include,but are not limited to: 1. Soil testing. 2. Concrete testing. 3. Steel connection testing. C. The Contractor shall provide to the Special Inspector a copy of each approved submittal related to structural systems, materials and components for use in verifying proper construction. Such submittals shall include,but are not limited to,the following: 1. Contract documents,including all revisions. 2. Concrete mix designs and test results. 3. Concrete reinforc7ig steel fabrication drawings. 4. Structural steel fabrication drawings. Atlantic Beach Country Club Page 2 of 4 Structural Inspection Plan 02/11/14 i MCVEIGH&MANGUM E N G I N E E K I N G • I N C D. All submittals provided to the Special Inspector shall bear the stamp and initials of the Contractor and the Architect or Engineer of Record. 4. BUILDING DESCRIPTION A. The project consists of two-story clubhouse. 5. SPECIAL INSPECTOR'S OBSERVATIONS The contract requirements for this project are contained in the Official Contract Documents. The following guidelines should be used in conjunction with a careful study of the Official Contract Documents. A. GENERAL 1. Review the Official Contract Documents to be sure that they are approved and available before the start of any phase of the structural work. 2. Observe that all tests,sampling or reports have been completed before finished work is covered and no longer capable of being inspected or tested. 3. Observe the repair and treatment of areas containing defective work. B. FOUNDATIONS 1. Prior to the placing of reinforcing in footings, observe, by reviewing the testing reports, that the required density f have been made. 2. Observe the place ,!t and size of anchor bolts and/or dowels. 3. Observe size,spat number and clearance of reinforcing. C. STRUCTURAL CONCRETE General 1. Observe that all structural embedded items are in place as shown on Official Contract Documents. 2. Before placement of concrete slab on grade, observe proper subsurface conditions, vapor barriers, reinforcing and siz,,,and location and formwork for construction joints,including joint locations. Reinforcine 1. Observe that reinforcing is placed in accordance with approved shop drawings and latest Official Contract Documettte Concrete 1. By reviewing test reports, observe that all concrete delivered is of an approved mix design and adequate records are being maintained by testing lab. j 2. Observe that all reinforcing and formwork has been installed and all necessary corrections made before placement of concrete. D. STRUCTURAL STEEL General 1. Observe the steel'with the plans and specifications. Steel Joists 1. Observe the steel joists for their depth and spacing and connections. Metal Deck 1. Observe the steel deck gauge, edge support, welding pattern, welding washers and touching welded areas with paint. Atlantic Beach Country Club " Page 3 of 4 Structural Inspection Plan 02/11/14 I J� MCVEIGH&MANGUM ENG INEEKING - INC E. PRE-ENGINEERED TRUSSES General 1. Observe that the spacing of trusses conforms to the structural and approved shop drawings. 2. Observe that the permanent bracing conforms to the approved engineered shop drawings. 3. Observe that the truss tie-down types are as specified,the attachments are complete and conform to the contract documents and approved engineered shop drawings. 4. Observe truss-to-truss connections conform with the approved engineered shop drawings. 5. Observe that the roof decking thickness and attachments conform to the construction documents and approved engineered shop drawings. F. WOOD General 1. Observe member sizes and spacing are as detailed on official contract documents or as otherwise approved. 2. Observe nailing, strapping and other connections area as detailed on the contract documents or as otherwise approved. I Atlantic Beach Country Club Page 4 of 4 Structural Inspection Plan 02/11/14 lAt � JAN 2 8 MCVEIGH&MANGUMS E N G I N E E R I N G - I N C January 28,2014 Atlantic Beach Partners,LLC c/o Mr. Pete Rodrigues, President RPC General Contractors, Inc. 248 Levy Road Atlantic Beach,FL 32233 Re: Threshold Inspection Services for Atlantic Beach Country Club Atlantic Beach,Florida Dear Mr.Rodrigues: We appreciate this opportunity to present a proposal to provide threshold inspection services for the above-referenced project. DESCRIPTION OF PROJECT The project consists of an amenity area including an approximately 12,000 SF clubhouse, in addition to an approximately 2,750 SF Tennis/Fitness/Pro Shop building connected by a breezeway to an approximately 650 SF Pool Bath building. The covered areas associated with these buildings totals approximately 3,400 SF of covered area. The project also includes an approximately 400 SF covered pavilion. SCOPE OF WORK The scope of work is to provide threshold building, structural inspection services for the referenced project. Our services will be limited to the inspection of the buildings' structural elements. All testing of foundation soils, steel connections, and concrete for this project are outside our scope of work and shall be performed by a qualified testing company. In order to satisfy our obligations as threshold inspector for this project and based on our review of the drawings along with our review of similar project types, we have estimated that we will perform approximately 20 site visits. Our fee per visit used in our fixed fee calculation is $425/visit, which includes all costs associated with the visit. Should our estimate be deemed to not be reasonable, we should be notified prior to the execution of this contract. Should the actual number of site visits significantly fall short of or exceed the stated assumed STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC •JACKSONVILLE,FL Threshold Inspection Services for Atlantic Beach Country Club Atlantic Beach Partners,LLC c/o RPC General Contractors,Inc. January 28,2014 Page 2 of 6 number, our fee for will be adjusted on the basis of the actual number of visits and the per visit fee stated above. In conformance with Section 553.79 Subsection 7(a) Florida Statues,at the completion of this project,we propose to provide a statement that to the best of our knowledge and belief, the construction of all structural load-bearing components for the referenced project complies with permitted documents. This proposal assumes reasonable conformance to the structural drawings by the contractor prior to threshold inspections and that the contractor implements an effective quality control program throughout the duration of the project as noted by the threshold inspection plan. FEE Based on the assumptions outlined above,we estimate that our total fee for our services will be: Structural Threshold Inspection Services $8,500.00 Inspections, in addition to the number stated in the scope of work outlined above, and any additional services outside the scope of work outlined above shall be charged on the basis of our standard hourly rates in effect at the time the additional services are performed. The standard hourly rates are currently as follows: Principal $185.00 Department Manager $155.00 Senior Engineer $140.00 Lead Engineer/Sr.Designer $130.00 Engineer/Designer $115.00 Jr.Engineer/Designer $100.00 CADD Operator $ 90.00 Project Coordinator $ 65.00 Clerical $ 65.00 Invoicing for services will be monthly. The proposed financial arrangements are on the basis of prompt payment of invoices within 60 days and the orderly and continuous progress of the project. If basic services have not been completed within 24 months of the acceptance date, through no fault of McVeigh and Mangum Engineering,Inc.,the engineering fee shall be equitably adjusted. REIMBURSEMENT EXPENSES Direct expenses incurred by the engineer due to travel more than 25 miles from our office, express mail charges, and bulk reproductions shall be considered reimbursable expenses and invoiced on the basis of actual cost plus ten percent(10%). TERMS AND CONDITIONS The terms and conditions of Exhibit A shall be part of this letter agreement. Threshold Inspection Services for Atlantic Beach Country Club Atlantic Beach Partners,LLC c/o RPC General Contractors,Inc. January 28,2014 Page 3 of 6 This proposal will remain open for acceptance for a period of six(6)months from the above date. If the information herein meets with your approval,please sign where indicated below and return a copy of this letter as our authorization to proceed. Notwithstanding the foregoing sentence, if you or members of your firm engage our firm in engineering design services for the referenced project, either verbally or by actions, which imply acceptance of this proposal such as providing us drawings, requesting engineering information, etc., without returning a signed copy of this proposal, acceptance of all conditions of this proposal will be implied. Sincerely, Wayne D. Mangum,P.E.,President For: McVeigh and Mangum Engineering,Inc. Accepte thi 2 d� day ofJ ,2014. By.-- For: y.—For: tl ach Partn ,LLC Threshold Inspection Services for Atlantic Beach Country Club Atlantic Beach Partners,LLC C/o RPC General Contractors,Inc. January 28,2014 Page 4 of 6 Exhibit A Terms and Conditions McVeigh&Mangum Engineering,Inc. (Design Professional)shall perform the services outlined in this letter agreement for the stated fee arrangement. Billings/Payments Invoices will be submitted monthly for services and reimbursable expenses and are due when rendered. Invoice shall be considered PAST DUE if not paid within 30 days after the invoice date and Design Professional may,without waiving any claim or right against Client,and without liability whatsoever to the Client,terminate the performance of the service. Retainers shall be credited on the final invoice. Accounts unpaid 30 days after the invoice date may be subject to a monthly service charge of 1.5%(or the legal rate)on the unpaid balance. In the event any portion of an account remains unpaid 90 days after billing,the Client shall pay all cost of collection,including reasonable attorneys'fees. In any event, Design Professional is not obligated to provide signed and sealed design documents until payment for its construction document services is received. Access To Site Unless otherwise stated,Design Professional will have access to the site for activities necessary for the performance of the service Hidden Conditions and Hazardous Materials A condition is hidden if concealed by existing finishes or if it cannot be investigated by reasonable visual observation. If Design Professional has reason to believe that such a condition may exist,Design Professional shall notify the Client who shall authorize and pay for all costs associated with the investigation of such a condition and,if necessary,all costs necessary to correct said condition. If(1)the Client fails to authorize such investigation or correction after due notification,or(2)Design Professional has no reason to believe that such a condition exists,the Client is responsible for all risks associated with this condition,and Design Professional shall not be responsible for the existing condition nor any resulting damages to persons or property. Design Professional shall have no responsibility for the discovery,presence,handling,removal,disposal or exposure of persons to hazardous materials of any form. Indemnifications The Client shall,to the fullest extent permitted by law,indemnify and hold harmless Design Professional, its officers,directors,employees,agents and subconsultants from and against all damage,liability and cost,including reasonable attorney's fees and defense costs,arising out of or in any way connected with the performance of the service under this Agreement,excepting only those damages,liabilities or costs attributable to the sole negligence or willful misconduct of Design Professional. This indemnification shall include any claim,damage or losses due to the presence of hazardous materials. Risk Allocation In recognition of the relative risks,rewards and benefits of the project to both the Client and Design Professional,the risks have been allocated so that the Client agrees that,to the fullest extent permitted by law,Design Professional's total liability to the Client,for any and all injuries,claims,losses,expenses, damages or claim expenses arising out of this agreement,from any cause or causes shall not exceed the Threshold Inspection Services for Atlantic Beach Country Club Atlantic Beach Partners,LLC c/o RPC General Contractors,Inc. January 28,2014 Page 5 of 6 total amount of$50,000,the amount of Design Professional's fee(whichever is greater)or other amount agreed upon when added to the letter agreement. Such causes include,but are not limited to,Design Professional's negligence,errors,omissions,strict liability,breach of contract or breach of warranty. Information for the Sole Use and Benefit of the Client All opinions and conclusions of Design Professional,whether written or oral,and any plans, specifications or other documents and services provided by Design Professional are for the sole use and benefit of the Client and are not to be provided to any other person or entity without the prior written consent of Design Professional. Nothing contained in this Agreement shall create a contractual relationship with or a cause of action in favor of any third party against either Design Professional or the Client. Ownership of Documents All documents produced by Design Professional under this Agreement are the instruments of Design Professional's professional service and shall remain the property of Design Professional and may not be used by the Client for any other purpose without the prior written consent of Design Professional. Termination of Services This agreement may be terminated upon 10 days written notice by either party should the other fail to perform his obligations hereunder. In the event of termination,the Client shall pay Design Professional for all services rendered to the date of termination,all reim—bursable expenses,and reasonable termination expenses. Certificate of Merit Prior to filing any claim,complaint or action against the Design Professionals,the Client must secure the written opinion of a licensed Design Professional experienced in the design of similar projects identifying all alleged errors and omissions,and the Client must provide the written opinion to the Design Professionals and allow sixty days for a reply. The Design Professionals are deemed to be intended third party beneficiaries of this provision. Dispute Resolution This agreement shall be governed by the laws of the principal place of business of Design Professional. Any claim,dispute or other matter in question arising out of or related to this Agreement shall be subject to mediation as a condition precedent to arbitration in accordance with the Construction Industry Mediation Rules of the American Arbitration Association currently in effect. The parties shall share the mediator's fee and any filing fees equally. The mediation shall be held in the place where the Design Professional is located,unless another location is mutually agreed upon. Agreements reached in mediation shall be enforceable as settlement agreements in any court having jurisdiction thereof. Claims, disputes and other matters that are not resolved by mediation shall be subject to and decided by arbitration in accordance with the Construction Industry Arbitration Rules of the American Arbitration Association currently in effect unless the parties mutually agree otherwise. The award rendered by the arbitrator or arbitrators shall be final,and judgment may be entered upon it in accordance with applicable law in any court having jurisdiction thereof. In no event shall the demand for mediation or arbitration be made after the date when institution of legal or equitable proceedings based on such claim,dispute or other matter in question would be barred by the applicable statute of limitations. Threshold Inspection Senices for Atlantic Beach Country Club Atlantic Beach Partners,LLC C/o RPC General Contractors,Inc. January 28,2014 Page 6 of 6 Severability and Survival If any of the provisions contained in this Agreement are held illegal,invalid or unenforceable,the enforceability of the remaining provisions shall not be impaired thereby. Limitations of liability and indemnities shall survive termination of this Agreement for any cause. No Third Party Beneficiaries This Agreement gives no rights or benefits to anyone other than the Client and Design Professional and has no third party beneficiaries. Design Professional services are defined solely by this Agreement and not by other contract or agreement which may be associated with the Project. J - lil J J January 30, 2014 Mr. Pete Rodrigues RPC General Contractors, Inc. 248 Levy Road Atlantic Beach, FL 32233 RE: Hydrant Flow Testing Dear Mr. Rodrigues: The City of Atlantic Beach flow-tested hydrants at the locations below. The results were as follows: Date of Flow Test: 7/30/2013 - 1 :30 p.m. Location: Near 1600 Selva Marina Dr. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE - 36 PSI GPM -1000 Date of Flow Test: 8/1/2013 - 9:45 a.m. Location: Intersection of Francis Ave. and Dutton Island Rd. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE — 40 PSI GPM — 1090 Please let me know if you need additional information by calling (904) 270-2535 or email me at dkaluzniakC@coab.us. Sincerely, Donna Kaluzniak, CEP Utility Director cc: Chris Walker, Division Director Public Utilities Department 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 City of Atlantic Beach APPLICATION NUMBER tri Building Department (To be assigned by the Building Department.) 800 Seminole Road �r Atlantic Beach, Florida 32233-5445 Z. Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: 12. City web-site: http://vmw.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: a0 JJ51KA_"A,1Z.(77�t gServices nt review re uired Yes No Applicant: Zoning is rator Project: /�V * L, ksies�v'QL.� d/1rtys �L u� Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by; Date: Revised 05/14/09 9042558559 JFRD-PLAN REVIEW 03:04:44 p.m. 02-03-2014 1 /1 i City of Atlantic Beach j Buildingbepartment APPLICATION NUMBER .� , (Co ba 06810ned by the;Butldmg Department) 800 Seminole Road o Atlantic Beach,Florida "2,_ ;y ,t Phone(904 247-5826 d(904 7-5845 i E-mail: buHdIng-depf@r,,.­413.us I D ate.routed �• � � / City web-site: http:/Avww,,­)abius APPLICATION RE VIEW AND TRACKING FORM I � Property Address: �De artment review re uired Yes No Building Applicant: i Planning&Zoning I ( Tree Administrator Project a I Public Works Public Utilities / I Pu Fire Services E Other Agenc� Review or ttrtttit R quired Review or Receipt Date i of Permit Verified B Florida Dept olEnvironmentai Protedio Florida Dept,o>'�TranspOrtar., f St.Johns RiverWater Mans:,=•ment Dis d Army Corps of Engineers I i Division Of Hote s and Resta.:rants i Division of Alco otic Beverag =and To eco Other: I I APP IICATION STATUS Reviewing Department Fi Review: App ved. Denied. (Circle one.) Comments: I BUILDING ; i PLANNING&ZONING I I Reviewed by: Date: TREE ADMIN. I j Second Revit QAp I ved as r ised. []Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY I Reviewed by: Date: FIRE SERVICES Thirld Review: _0ppr ved as revised. ❑Denied. ComYnents: ii Reviewed Date: 3 Revised 05/14/09 l j-lrl r s CITY OF ATLANTIC BEACH PUBLIC UTILITIES J `~ 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 (904) 270-2535 or(904) 247-5874 NEW WATT ERISEWER TAP REQUEST Date: 2/10/14(Revision 2) , Project Address: 1600 Selva Marina Dr. No. of Units: 1 Commercial X Residential Multi-Family New Water Tap(s) &Meter(s)_Existing 2"Meter Meter Size(s)_g" New Irrigation Meter Upgrade Existing Meter from to (size) New Connection to City Sewer�E-xisting Name: RPC General Contractor -Pete Rodrigues Applicant Address: 248 Levy Rd. City: Atlantic Beach State: FL Zip: 32233 Phone Number: 241-4416 Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# 13-3848 New clubhouse and other buildings Water System Development Charge $ for ABCC. Sewer System Development Charge $ Water Meter Only $ The existing 2"meter will be used. Water Meter Tap $ Sewer Tap $ There will also be a 6" fireline meter Cross Connection , $ 200 installed—no impact fees for that Other $ meter. TOTAL $ $ 200 (notes) APPROVED: _Donna Kaluzniak 2/10/14 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED r CITY OF ATLANTIC BEACH PUBLIC UTILITIES yr 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 r� 0111 r (904) 270-2535 or(904) 247-5874 NEW WAS ERISEWER TAP REQUEST �OrUb Date: 2/10/14(revised) Project Address: 1600 Selva Marina Dr. No. of Units: 1 Commercial X Residential Multi-Fami New Water Tap(s) &Meter(s) Upgade meter for clubhouse& amenitie Meter Size(s)_ New Irrigation Meter Upgrade Existing Meter from to 3" (size) New Connection to City Sewer Existing Name: RPC General Contractor -Pete Rodripues Applicant Address: 248 Levy Rd. City: Atlantic Beach State: FL Zip: X3233 Phone Number: 241-4416 Cell Number: Email Address Fax:_ Signature: (Applicant) CITY STAFF USE ONLY Application# 13-3848 New clubhouse and other buildings Water System Development Charge 5 324 for ABCC. Based on new 3"meter, Sewer System Development Charge _18,913_ upgraded from 2"meter. Water Meter Only $ Water Meter Tap $ There will also be a 6" fireline meter Sewer Tap $ installed—no impact fees for that Cross Connection $ 200 meter. Other $� Water=(3")$11,400—(29')$6,076=$5,324 TOTAL $ $24,437 Sewer=(3")$40,500-(2")$21,587=$18,913 (notes) APPROVED: Donna Kaluzniak 2/10/14 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED L 1\lel Al\JJL 4 1 V 12 1 11 . G V G V 1't-111.1Li1V 1 J 1/UL' r11. l.L'1Y 1 CITY OF ATLANTIC BEACH PROGRAM BP820L ---------------------------- -------------------- --- -- ------------------ --- - APPLICATION NUMBER: 13-00003848 1600 SELVA MARIN-', DR FEE DESCRIPTION AMOUNT DUE --------------------- ----- - - ------------------- -- -- - --- ------------------- - STATE DCA SURCHARGE 182 . 19 DEV REVIEW-COMMERCIAL/IND 100 . 00 PLAN CHECK FEES 6073 . 0 COMMERCIAL NEW 12146 . 0 STATE DBPR SURCHARGE 182 19 / SEWER SDC-SYSTEM DEV CHG 1891 . 00v" UTIL REV COMMERCIAL BLDG 5 . 00 ��ff WATER CROSS CONNECTION 00 . 00 .- WATER SDC-SYSTEM DEV CHG 324 . 00v TOTAL DUE 3195 . 38 Please present this recei t to the cashier with full payment . 3 ' 1JJ CITY OF ATLANTIC BEACH _ PUBLIC UTILITIES Z, 1200 Sandpiper Lane ATLANTIC BEACH,FL 32233 r i (904) 270-2535 or (904) 247-5874 NEW WATER/SEWER TAP REQUEST ��� trUb Date: 2/10/14 (revised) Project Address: 1600 Selva Marina Dr. No. of Units: 1 Commercial X Residential Multi-Family New Water Tap(s) &Meter(s) Upgrade meter for clubhouse& amenities Meter Size(s)_ New Irrigation Meter Upgrade Existing Meter from 2" to 3" (size) New Connection to City Sewer Existing Name: RPC General Contractor -Pete Rodriug_es Applicant Address:_248 Levy Rd. City: Atlantic Beach State: FL Zip: 32233 Phone Number: 241-4416 Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# 13-3848 i New clubhouse and other buildings Water System Development Charge $ 5 324 for ABCC. Based on new 3"meter, Sewer System Development Charge $ 18,913 upgraded from 2"meter. Water Meter Only $ Water Meter Tap $ There will also be a 6" fireline meter Sewer Tap $ installed-no impact fees for that Cross Connection $ 200 meter. Other $ Water=Q")$11,400—(2")$6,076=$5,324 TOTAL $ $24,437 Sewer(3")$40,500-(2")$21,587=$18,913 (notes) APPROVED: Donna Kaluzniak 2/10/14 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED CITY OF ATLANTIC BEACH � SS1 - PUBLIC UTILITIES +� �r 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 (904) 270-2535 or(904) 247-5874 NEW WATER/SEWER TAP REQUEST Date: 12/20/13 Project Address: 1600 Selva Marina Dr. No. of Units: 1 Commercial X Residential Multi-Family New Water Tap(s) &Meter(s) New meter for clubhouse& amenities eter Size(s) 3" New Irrigation Meter Upgrade Existing Meter from (size) New Connection to City Sewer X Name: RPC General Contractor -Pete Rodregges Applicant Address: 248 Leyy Rd. City: Atlantic Beach State: FL Zip: 32233 Phone Number: 241-4416 Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# 13-3848 New clubhouse and other buildings Water System Development Charge $ 11 0 for ABCC. Based on 3"meter. Sewer System Development Charge $ 4 500 Water Meter Only $ There will also be a 6"fireline meter Water Meter Tap $ installed—no impact fees for that Sewer Tap meter. Cross Connection 200 Other $ TOTAL $ $52,100 (notes) APPROVED: Donna Kaluzniak 12/20/13 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED Graham, Shirley From: Kaluzniak, Donna Sent: Monday, 1 z�•ruary 10, 2014 11:04 AM To: Graham, Sh:'rley Subject: 1600 Selva Marina Dr2 Attachments: 1600 Selva Marina Dr2.docx Shirley, here is the revised Water/Sewer fee schedule. Per City Code,when upgrading from one size meter to another, we take the fees for the larger meter and subtract what would be the fees for the smaller. Thanks, Donna Graham, Shirley From: Kaluzniak, Donna Sent: Monday, February 10, 2014 11:41 AM To: Pete Rodrig,.:es Cc: Graham, Shirley; Walker, Jennifer Subject: RE: Utility fees-ABCC Attachments: 1600 Selva Marina Dr2.docx Pete, will do. Jenny/Shirley - per Pete's email below - ABCC will use the existing 2-inch meter instead of upgrading to a 3-inch meter for the clubhouse. We only need to charge the $200 cross-connection inspection fee. - Donna Donna Kaluzniak, Utility Director City of Atlantic Beach 902 Assisi Lane Atlantic Beach, FL 32233 (904) 270-2535 dkaluzniak@coab.us -----Original Message----- From: Pete Rodrigues [mailto:P;:-to@rpcgc.com] Sent: Monday, February 10, 2014 11:34 AM To: Kaluzniak, Donna Subject: Re: Utility fees - ABCC Use the existing 2" please Pete Rodrigues, President RPC General Contractors, Inc. > On Feb 10, 2014, at 11:32, "Kaluzniak, Donna" <dkaluzniak@coab.us> wrote: > Pete, do you mean if you keep just a 2" meter instead of a 3" meter? - If so - there would be no additional water/sewer fees (fees are based on meter size). > Or do you mean have the 3" plus a 2"? Which would be the amount I originally (mistakenly) had on the form for a new 3" meter. - Donna > -----Original Message----- > From: Pete Rodrigues [mailto.Pete@rpcgc.com] > Sent: Monday, February 10, 2014 11:27 AM > To: Kaluzniak, Donna > Subject: Re: Utility fees - ABCC > Another question would be . . . What would the fees be if we keep the existing meter . . . The Developer ( my boss) will want to know > Thanks > Pete Rodrigues, President > RPC General Contractors, Inc. >> On Feb 10, 2014, at 11:24, "l;aluzniak, Donna" <dkaluzniak@coab.us> wrote: >> Pete, I sent Shirley a revised form. >> Per our City Code, we must subtract the fees for the existing 2" meter from the fees for the new 3" meter. >> My apologies - I filled out the form as if it were a new meter vs. an upgrade. >> Here is the correct fee. Thanks, Donna >> Donna Kaluzniak, Utility Director >> City of Atlantic Beach >> 902 Assisi Lane >> Atlantic Beach, FL 32233 >> (904) 270-2535 >> dkaluzniak(@coab.us >> -----Original Message----- » From: Pete Rodrigues [mailt-.._.Pete(@rpcgc.com] >> Sent: Monday, February 10, 2014 11:20 AM >> To: Kaluzniak, Donna >> Subject: Utility fees - ABC >> Donna >> While we work out the utility fees for the ABCC . . . Can we at least release the building permit and put a hold on CO until paid . . . Please let me know >> Thanks >> Cell= 545-5911 if you need to reach me >> Pete Rodrigues, President >> RPC General Contractors, Iv >> <1600 Selva Marina Dr2.docx,> 2 City of Atlantic Beach APPLICATION NUMBER Building Department Sd (To be assigned by the Building Department.) r >< 800 Seminole Road z, Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 !'55 ,19, E-mail: building-dept@coab.us Date routed: / City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I V Dk view re uired Yes No PI �J ui Applicant: C.►. an reer Project: b/d- (� u Cj Q u l V ire Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: y�Approved. ❑Denied. (Circle one.) Comments: �� BUILDING PLANNING &ZONING Reviewed by: 4 Date: ()409)v TREE ADMIN. Second Review: []Approved as revised. []Denie . PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W)/ Dec 13, 2013 (ES) Date of Issuance: Designer: Taylor&White& Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION 1 Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks (-40" and -30") and one 12" palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal (3" to 1" for removal of heritage trees from ROW, i.e., LO => 30"). 2 Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. 3 Landscape plans do not include proposed restoration of ground under removed crossovers (sod, trees, etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. 4 Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. C:\Users\sgraham\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.0utlook\MTOZPOFY\City Review Comments_ABCC clubhouse_carper.doc Page 1 DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W) / Dec 13, 2013 (ES) Date of Issuance: Designer:Jaylor& White & Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION C:1Users\sgraham\AppDatalLocallMicrosoftlWindowslTemporary Internet FileslContent.OutlooklMTOZPOFY\City Review Comments_ABCC clubhouse_carper.doc Page 2 DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W) / Dec 13, 2013 (ES) Date of Issuance: Designer: Taylor& White & Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION C:\Users\sgrahamlAppData\Local\MicrosoftlWindows\Temporary Internet Files\Content.0utlook\MTOZPOFY\City Review Comments_ABCC clubhouse_carper.doc Page 3 DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W) / Dec 13, 2013 (ES) Date of Issuance: Designer: Taylor&White & Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION C:1Users\sgraham\AppDatalLocallMicrosoftlWindows\Temporary Internet Files\Content.Outlook\MTOZPOFY\City Review Comments_ABCC clubhouse_carper.doc Page 4 City of Atlantic Beach Rte('r.')Z jj; APPLICATION NUMBER JS �� Building Department _ (To be assigned by the Building Department.) 800 Seminole Road - Atlantic Beach,Florida 32233-5445 ! Phone(904)247-5826 • Fax(904)2}7-5845 ^101119' E-mail: building-dept@coab.us ` -` -`------ Date routed: Z City web-site: http,//www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address:_A�6 �y DapartLnent review re wired Yes No AA ui Applicant: le'1`15nning&Zonin ree Ad istrator Project: u lic utilitie u lic Safety ire Service Review fee$_.�r 15" _Dept Signature Other Agency Review or Permit Required ^° 'teceipt Date of Permit Verified B Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other. APPLICATION STATUS Reviewing Department First Review: XApproved. [-]Denied. (Circle one.) Comments: BUILDING PLANNING&ZONING Reviewed by:� vv Date: � � /3 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denietl. X IC Comments: C UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 05/14/09 CITY OF ATLANTIC BEACH Building Department a 800 Seminole Road Atlantic Beach,Florida 32233 - (904)247-5800 PLAN REVIEW COMMENTS Permit Application # g- Property Address: A- Applicant: R P C' Project: 11/(�f^,, /�, SP/V A G• C. This permit application has been: Approved El Reviewed and the following items need attention: VC r �` � � S r1�/ i✓1 � � 3 � (:1-VD,*ols` $ O AJotc' j►^/ Le I414 S p4,,/ o rV o2 d'7W Please re-submit your application when these items have been completed. Reviewed By: - Date: rSy>>lr; City of Atlantic Beach APPLICATION NUMBER ,. Building Department (To be assigned by the Building Department.) r' 800 Seminole Road 12 - 3g -1 j Atlantic Beach, Florida 32233-5445 `7(Q _ Phone (904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: 12-11 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: &d&hl(/Q Department review required Yes No Building Applicant: Planning &Zoning Tree Administrator Project: a Public Works Public Utilities PojcLaWly Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as r vised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: PApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 t+ J January 30, 2014 Mr. Pete Rodrigues RPC General Contractors, Inc. 248 Levy Road Atlantic Beach, FL 32233 RE: Hydrant Flow Testing Dear Mr. Rodrigues: The City of Atlantic Beach flow-tested hydrants at the locations below. The results were as follows: Date of Flow Test: 7/30/2013 - 1 :30 p.m. Location: Near 1600 Selva Marina Dr. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE - 36 PSI GPM -1000 Date of Flow Test: 8/11/2013 - 9:45 a.m. Location: Intersection of Francis Ave. and Dutton Island Rd. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE — 40 PSI GPM — 1090 Please let me know if you need additional information by calling (904) 270-2535 or email me at dkaluzniakC@coab.us. Sincerely, Donna Kaluzniak, CEP Utility Director cc: Chris Walker, Division Director Public Utilities Department 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 _ J U January 30, 2014 Mr. Pete Rodrigues RPC General Contractors, Inc. 248 Levy Road Atlantic Beach, FL 32233 RE: Hydrant Flow Testing Dear Mr. Rodrigues: The City of Atlantic Beach flow-tested hydrants at the locations below. The results were as follows: Date of Flow Test: 7/30/2013 - 1:30 p.m. Location: Near 1600 Selva Marina Dr. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE - 36 PSI GPM -1000 Date of Flow Test: 8/1/2013 - 9:45 a.m. Location: Intersection of Francis Ave. and Dutton Island Rd. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE — 40 PSI GPM — 1090 Please let me know if you need additional information by calling (904) 270-2535 or email me at dkaluzniak(abcoab.us. Sincerely, Donna Kaluzniak, CEP Utility Director cc: Chris Walker, Division Director Public Utilities Department 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 I ZI Al 47- "-/ W--; 11 luau /c/ yon �, � n )Lf�� �Pra �6- � flc � � m � Graham, Shirley From: Ratliff, Bob ,Ratliff@coj.net] Sent: Friday, Ja lry 31, 2014 2:58 PM To: Graham, ley Cc: Griffin, Mi, .: al; Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: RE: plan re, :ew for ABCC Shirley,Jennifer, Mike and All! I have received and reviewed the thirc :bmittal information for the Atlantic Beach Country Club.The plans will be approved with this additional informal n and I hope to have the documentation returned to your office by close of business Monday. If I need to sign the permit application I can do that when the plans are delivered to your office or if you need it before then, please send a scanned copy and I will sign and return. Thank you, eaptairt 204 J&dW, UPS Jacksonville Fire & Rescue Departmer Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public: rds law,e-mail communications to and from city officials are subject to public disclosure. From: Ratliff, Bob Sent: Wednesday, January 29, 2014 3:27 PM To: 'Graham, Shirley' Cc: 'Griffin, Michael'; 'Walker, Jennifer'; 'Jones, Mike'; 'Hubsch, Jeremy' Subject: RE: plan review for ABCC The second submittal for Atlantic Bea .. juntry Club has been reviewed and the comments are attached. I will try to get the plans returned before close o` �iness today. Thanks, Captain 0-6 9?atW, UPS Jacksonville Fire & Rescue Departmen' Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax 1 CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public,u-, ds law,e-mail communications to and from city officials are subject to public disclosure. From: Ratliff, Bob Sent: Monday, January 27, 2014 1:49 PM To: 'Graham, Shirley'; Groff, James Cc: Griffin, Michael; Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: RE: plan review for ABCC I will try to get by tomorrow morning to pick the plans up. Thank you, e t'ta& XoA 9?adW, CFPS Jacksonville Fire & Rescue Department Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public re )rds law,e-mail communications to and from city officials are subject to public disclosure. From: Graham, Shirley [mailto:sgraham(&coab.us] Sent: Monday, January 27, 2014 9:43 AM To: Ratliff, Bob; Groff, James Cc: Griffin, Michael; Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: plan review for ABCC Bob, We have revisions for you to look z for the Atlantic Beach Country Club. sKrleU etraham Building Department 800 Seminole Rd Atlantic Beach, Fl 32233 904 247 5800 sgraham@coab.us 2 rs�.sr�rJJCity of Atlantic Beach APPLICATION NUMBER Itt Building Department (To be assigned by the Building Department.) 800 Seminole Road p �r Atlantic Beach, Florida 32233-5445 3 Q Phone(904)247-5826 • Fax(904) 247-5845 o;t>>r E-mail: building-dept@coab.us L Date routed: Z / City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I V Q. D ent review required Yes oeNo ui Applicant: anning &Zonin AT-reeMistrator Project: 1/� , Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco ._ Other: APPLICATION STATUS Reviewing Department First Review: %proved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING 3 7,/ Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) -i 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 ��J �Is)) E-mail: building-dept@coab.us L Date routed: City web-site: http://www.coab.us 7 if APPLICATION REVIEW AND TRACKING FORM Property Address: �j/ D ent review required Yes No AA ui Applicant: anning &Zonin ree Ad istrator Project: V4_ el u 049 lic Utilitie u is Safety ire Service Revlew . Dept Signature. t Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: ` APPLICATION STATUS Reviewing Department First Review: QA prttGed. ❑Denied. (Circle one.) Comments: BUILDING v ING &ZONIN Reviewed bya?7�9�' �� Date: TREE ADMIN. Second Review: A roved as revised. ❑ pP ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 EF 1'�L Lek Florida Energy Efficiency Code For Building Construction EnergyGauge Summit® Fla/Com-2010, Effective Date: March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: 13093 Description: Atlantic Beach Country Club Owner: Addressl: Enter Address here City: Atlantic Beach Address2: Enter Address here State: FL Zip: 32233 Type: Exercise Center Class: New Finished building Jurisdiction: DUVAL COUNTY,DUVAL COUNTY,FL(26 1000) Conditioned Area: 3959 SF Conditioned&UnConditioned Area: 3959 SF No of Stories: 1 Area entered from Plans 12211 SF Permit No: 0 Max Tonnage 9.2 If different,write in: pNhauuuwwnu,,,�I,' ,.-♦' `� •.y`C Ely ''•.. • 0.40287 ' STATE F . EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software, Effective Date:March 15,2012 12/13/2013 Page 1 of 8 Compliance Summary Component Design Criteria Result Gross Energy Cost(in $) 2,064.0 2,465.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS Not Checked PIPING SYSTEMS PASSES Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 2 of 8 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Michael Kratky Building Official: Date: Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Susan Wood Date: If Required by Florida law, I hereby certify(")that the system design is in compliance with the Florida Energy Efficiency Code Architect: Cliff Duch Reg No: AR 0014227 Electrical Designer: Thomas C.Nielsen Reg No: 53492 Lighting Designer: Thomas C.Nielsen Reg No: 53492 Mechanical Designer: Farshid Yarizadeh Reg No: 40287 Plumbing Designer: Farshid Yarizadeh Reg No: 40287 ( ) Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 3 of 8 Project: 13093 Title: Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Building End Uses 1) Proposed 2) Baseline Total 129.30 193.70 $2,064 $3,081 ELECTRICITY(Ml3tu/kWh/$) 129.30 193.70 37877 56742 $2,064 $3,081 AREA LIGHTS 21.30 44.50 6229 13038 $339 $708 MISC EQUIPMT 19.30 19.30 5645 5645 $308 $307 PUMPS & MISC 0.30 0.30 73 75 $4 $4 SPACE COOL 53.80 53.50 15775 15672 $860 $851 SPACE HEAT 7.00 17.80 2060 5222 $112 $284 VENT FANS 27.60 58.30 8095 17090 $441 $928 Credits Applied: None PASSES Passing Criteria=2465 Design (including any credits)=2064 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 67% EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 4 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File:FL_JACKSONVILLE_INTL ARPT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) Ext Light 1 Main entries Yes 30.00 30.0 900 600 Ext Light 2 Other(doors)than main entries Yes 20.00 12.0 240 120 Ext Light 4 Walk way less than 10 feet wide Yes 1.00 83.0 83 240 Ext Light 5 Canopies(freestanding,attached Yes 1.25 800.0 1,000 135 and Overhangs) Tradable Surfaces: 1095 (W)Allowance for Tradable: 1978.1 (W) PASSES All External Lighting: 1095(W) Complicance check includes a excess/Base allowance of 600.00(W) Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File: FL JACKSONVILLE INTL ARPT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance 141 5 Corridor 54 1 1 PASSES 142 6 Toilet and Washroom 271 2 1 PASSES 143 10,012 Laundry-Washing 150 1 1 PASSES 144 5 Corridor 54 1 1 PASSES 145 6 Toilet and Washroom 271 2 1 PASSES 009 3 Storage&Warehouse-Bulky 58 1 1 PASSES Active Storage 011A 1 Electrical Mechanical Equipment 50 1 1 PASSES Room-General 150 12 Lobby(General)-Reception and 166 1 1 PASSES Waiting 151 8,001 Exercise Area(Exercise Center) 755 1 1 PASSES 152 6 Toilet and Washroom 261 2 1 PASSES 153 6 Toilet and Washroom 261 2 1 PASSES 154 8,001 Exercise Area(Exercise Center) 1,185 1 1 PASSES 160 25,001 Sales Area 385 1 1 PASSES 161 3 Storage&Warehouse-Bulky 38 1 1 PASSES Active Storage PASSES EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date. March 15,2012 12/13/2013 Page 5 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File:FL_JACKSONVILLE_INTL ARPT.tm3) System Report Compliance OAU-1 Dedicated Outside Air Unit System Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 14.40 12.23 14.40 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 0.57 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-8 Heat Pump Split System Constant Volume Packaged No.of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.00 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 3.30 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.63 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) �—PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date: March 15,2012 12/13/2013 Page 6 of 8 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File:FL_JACKSONVILLE_INTL ARPT.tm3) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss fiance Water Heater 1 Gas Instantaneous Unknown 95.00 Not Checked water heater Not Checked Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] [F] .SF.F] Domestic and Service Hot Water 1.50 False 140.00 0.28 1.50 1.00 PASSES Systems Domestic and Service Hot Water 1.50 False 120.00 0.28 1.50 1.00 PASSES Systems PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 7 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File:FL JACKSONVILLE_INTL_ARPT.tm3) Other Required Compliance Categor, Section Requirement(write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfm/ft2;all FA other products:0.3 cfin/ft2 Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed Dropped Ceiling 502.3 Vented:seal&insulated ceiling.Unvented seal&insulate roof& Cavity side walls HVAC Efficiency 503.2.3 Minimum efficiencies:Tables 503.2.3(1)-(8) El HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed FA HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall be mechanically attached,sealed,insulated&installed per Table 503.2.7.2.Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat trap required. Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce El heat loss on heated pools;Time switch(exceptions);readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2,502.3 Automatic control required for interior lighting in buildings 0 >5,000 s.f.;Space control;Exterior photo sensor;Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 8 of 8 EnergyGauge Summit a v4.10 INPUT DATA REPORT Proiect Information Project Name: 13093 Orientation: North Project Title: Atlantic Beach Country Club,Fitness Center Building Type: Exercise Center Address: Enter Address here Building Classification: New Finished building Enter Address here State: FL, No.of Stories: 1 Zip: 32233 GrossArea: 3959 SF Owner: Zones No AcronN m Description Type Area Multiplier Total Area lsq lsfl I Zone 1 Pool Services CONDITIONED 858.0 1 858.0 ❑ Zone 2 Fitness Center CONDITIONED 3100.8 1 3100.8 ❑ 12/13/2013 EnergyGauge Summit®v4.10 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN IN Iftl plier jsfj lcfl In Zone: Zone 1 1 141 Vestibule Corridor 7.35 7.35 9.00 1 54.0 486.2 ❑ 2 142 Men's Restroom Toilet and Washroom 16.46 16.46 9.00 1 270.9 2438.4 El 3 143 Laundry Laundry-Washing 12.25 12.25 9.00 1 150.1 1350.6 ❑ 4 144 Vestibule Corridor 7.35 7.35 9.00 1 54.0 486.2 ❑ 5 145 Women's Restroom Toilet and Washroom 16.46 16.46 9.00 1 270.9 2438.4 ❑ 6 009 Storage Storage&Warehouse- 7.61 7.62 9.00 1 58.0 521.9 Bulky Active Storage In Zone: Zone 2 1 011A Mechanical Electrical Mechanical 7.07 7.07 9.00 1 50.0 449.9 ❑ Equipment Room-General 2 150 Reception Lobby(General)-Reception 12.89 12.88 11.33 1 166.0 1881.0 ❑ and Waiting 3 151 Group Fitness Exercise Area(Exercise 27.48 27.48 11.33 1 755.2 8555.9 ❑ Center) 4 152 Men's Restroom Toilet and Washroom 16.16 16.15 9.00 1 261.0 2348.9 ❑ 5 153 Women's Restroom Toilet and Washroom 16.16 16.15 9.00 1 261.0 2348.9 ❑ 6 154 Exercise Room Exercise Area(Exercise 34.42 34.42 11.33 1 1184.7 13423.1 ❑ Center) 7 160 Tennis Pro Shop Sales Area 19.62 19.62 11.33 1 384.9 4361.4 El 8 161 Closet Storage&Warehouse- 6.16 6.16 9.00 1 37.9 341.5 El Bulky Active Storage Lighting No Type Category No.of Watts per Power Control Type No.of Luminaires Luminaire IWI Ctrl pts In Zone: Zone 1 12/13/2013 EnergyGauge Summit®v4.10 2 In Space: 141 1 LED General Lighting 1 15 15 Manual On/Off I E] In Space: 142 1 LED General Lighting 2 15 30 Manual On/Off 1 2 Suspended Fluorescent General Lighting 4 58 232 Manual On/Off 1 E] In Space: 143 1 Suspended Fluorescent General Lighting 2 58 116 Manual On/Off 1 El In Space: 144 1 LED General Lighting 1 15 15 Manual On/Off 1 In Space: 145 1 LED General Lighting 4 15 60 Manual On/Off I 2 Suspended Fluorescent General Lighting 3 58 174 Manual On/Off 1 In Space: 009 1 Suspended Fluorescent General Lighting 1 58 58 Manual On/Off I El In Zone: Zone 2 In Space: 011A 1 Suspended Fluorescent General Lighting 1 58 58 Manual On/Off 1 El In Space: 150 1 LED General Lighting 2 15 30 Manual On/Off 1 In Space: 151 1 LED General Lighting 12 30 360 Manual On/Off 1 El In Space: 152 1 LED General Lighting 4 15 60 Manual On/Off 1 El 2 Suspended Fluorescent General Lighting 3 58 174 Manual On/Off 1 E] In Space: 153 i LED General Lighting 5 15 75 Manual On/Off 1 El 2 Suspended Fluorescent General Lighting 3 58 174 Manual On/Off I El In Space: 154 1 LED General Lighting 16 15 240 Manual On/Off 1 In Space: 160 1 LED General Lighting 7 15 105 Manual On/Off I E] In Space: 161 1 Suspended Fluorescent General Lighting 1 58 58 Manual On/Off 1 El 12/13/2013 EnergyGauge Summit®A.10 3 Walls No Description Type Width H(Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sfJ [Btu/hr.sf.F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: Zone 1 1 N Wall Assembly 13093-Wall 27.33 9.00 1 246.0 North 0.0450 1.515 10.32 22.2 ❑ Assembly 2 E Wall Assembly 13093-Wall 39.25 9.00 1 353.3 East 0.0450 1.515 10.32 22.2 ❑ Assembly 3 S Wall Assembly 13093-Wall 27.33 9.00 1 246.0 South 0.0450 1.515 10.32 22.2 ❑ Assembly 4 W Wall Assembly 13093-Wall 39.25 9.00 1 353.3 West 0.0450 1.515 10.32 22.2 ❑ Assembly 5 N Wall(2)Assembly 13093-Wall 6.50 9.00 1 58.5 North 0.0450 1.515 10.32 22.2 ❑ Assembly 6 S Wall(2)Assembly 13093-Wall 6.50 9.00 1 58.5 South 0.0450 1.515 10.32 22.2 ❑ Assembly In Zone: Zone 2 1 N Wall Assembly 13093-Wall 78.33 11.33 1 887.5 North 0.0450 1.515 10.32 22.2 ❑ Assembly 2 E Wall Assembly 13093-Wall 70.17 11.33 1 795.0 East 0.0450 1.515 10.32 22.2 ❑ Assembly 3 N Wall Assembly 13093-Wall 78.33 11.33 1 887.5 South 0.0450 1.515 10.32 22.2 ❑ Assembly 4 W Wall Assembly 13093-Wall 70.17 11.33 1 795.0 West 0.0450 1.515 10.32 22.2 ❑ Assembly 5 SW Wall 13093 -Wall 10.33 11.33 1 117.0 SouthWes 0.0450 1.515 10.32 22.2 ❑ Assembly t Windows No Description Type Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area jBtu/hr sf F] [ft] IN plier [s{1 12/13/2013 EnergyGauge Summit®v4.10 4 In Zone: Zone 1 In Wall: E Wall 1 24x24 Window User Defined Yes 0.4000 0.40 0.40 2.00 2.00 2 8.0 In Wall: N Wall 1 24x24 Window User Defined Yes 0.4000 0.40 0.40 2.00 2.00 2 8.0 In Wall: W Wall 1 24x24 Window User Defined Yes 0.4000 0.40 0.40 2.00 2.00 2 8.0 In Zone: Zone 2 In Wall: E Wall 1 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 2 33.4 El 2 24x24 Window User Defined No 0.4000 0.40 0.40 2.00 2.00 3 12.0 In Wall: N Wall 1 30x80 Windows User Defined No 0.4000 0.40 0.40 2.50 6.67 2 33.4 2 24x24 Window User Defined No 0.4000 0.40 0.40 2.00 2.00 4 16.0 El In Wall: S Wall 2 24x24 Window User Defined No 0.4000 0.40 0.40 2.00 2.00 4 16.0 3 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 2 33.4 4 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 4 66.7 F] 5 30x50 Window User Defined No 0.4000 0.40 0.40 2.50 4.17 2 20.9 In Wall: SW Wall 1 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 2 33.4 In Wall: W Wall 1 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 2 33.4 3 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 6 100.1 4 30x50 Window User Defined No 0.4000 0.40 0.40 2.50 4.17 4 41.7 Doors No Description Type Shaded? Width H(Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ftl plier [sfl [Btu/hr.A.F] [lb/cfl [Btu/sf.F] [h.sf.FBtul In "Lone: Zone 1 In Wall: S Wall 1 PrOZolOWa3Dr1 Aluminum door, No 3.00 8.00 3 24.0 0.1919 43.67 0.53 5.21 1.25 in. polystyrene In Wall: N Wall(2) 12/13/2013 EnergyGauge Summit®v4.10 5 I PrOZo1OWa3Dr1 Aluminum door, No 3.00 8.00 1 24.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Wall: S Wall(2) 1 PrOZo1OWa3Dr1 Aluminum door, No 3.00 8.00 1 24.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Zone: Zone 2 In Wall: N Wall 1 PrOZo1OWa3Dr1 Aluminum door, No 3.00 8.00 2 24.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Wall: S Wall 1 PrOZo1OWa3Dr1 Aluminum door, No 3.00 8.00 2 24.0 0.1919 43.67 0.51, 5.21 ❑ 1.25 in. polystyrene Roofs No Description Type Width H(Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sf] [deg] [Btu/hr.Sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] In Zone: Zone l 1 Zone 1 Roof Roof Assembly 29.29 29.29 1 857.9 0.00 0.0395 1.20 11.06 25.3 ❑ Assembly In 7.one: Zone 2 1 Zone 2 Roof Roof Assembly 55.68 55.69 1 3100.8 0.00 0.0395 1.20 11.06 25. ❑ Assembly Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] IN [Sf] [Sf] In Zone: In Roof: 12/13/2013 EnergyGauge Summit®v4.10 6 Floors No Description Type Width H(Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr.sf.F] [Btu/sf.F] [Ib/cf] [h.sLF/Btu] In Zone: Zone 1 1 Zone 1 Floor 1 ft.soil,concrete 29.29 29.29 1 857.9 0.2681 34.00 113.33 3.73 0 floor,carpet and rubber pad In Zone: Zone 2 1 Zone 2 Floor 1 ft.soil,concrete 55.68 55.69 1 3100.8 0.2681 34.00 113.33 3.73 Q floor,carpet and rubber pad Systems OAU-1 Dedicated Outside Air Unit System Constant Volume Air Cooled Split No. Of Units l System <65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 60900.00 14.40 14.40 ❑ 2 Heating System 38557.00 1.00 ❑ 3 Air Handling System-Supply 650.00 0.57 4 Air Distribution System(Sup) 6.00 5 Air Distribution System(Ret) 6.00 AHU-8 Heat Pump Split System Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV I Cooling System 109900.00 11.00 12.00 E-1 2 Heating System 130000.00 3.30 ❑ 3 Air Handling System-Supply 3500.00 0.63 ❑ 4 Air Distribution System(Sup) 6.00 ❑ 5 Air Distribution System(Ret) 6.00 ❑ 12/13/2013 EnergyGauge Summit®v4.10 7 Plant Equipment Category Size Inst\o I"ff. IPLV Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss I Gas Instantaneous water heater [Gal] 199000 [Btu/%] 95.0000 [EFF-t] [Btu/h] ❑ Ext-Lighting Description Category No.of Watts per Area/Len/No.of units Control Type - Wattage Luminaires Luminaire [sf/ft/No] [W] 1 Ext Light 1 Main entries 10 60 30.00 Astronomical Timer Coj 600.00 ❑ 2 Ext Light 2 Other(doors)than main 2 60 12.00 Astronomical Timer Coi 120.00 ❑ entries 3 Ext Light 4 Walkway less than 10 feet 4 60 83.00 Astronomical Timer Coi 240.00 ❑ wide 4 Ext Light 5 Canopies(freestanding, 9 15 800.00 Astronomical Timer Coi 135.00 ❑ attached and Overhangs) Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] Btu-in/h.sf.F] ]inj ]in] 1 Domestic and Service Hot Water Systems 140.00 0.28 1.50 1.50 No ❑ 2 Domestic and Service Hot Water Systems 120.00 0.28 1.50 1.50 No ❑ 12/13/2013 EnergyGauge Summit®v4.10 8 Fenestration Used Name Glass Type No.of Glass SHGC VLT Panes Conductance [Btu/h.sf.FI 13093 Window User Defined 1 0.4000 0.4000 0.4000 ❑ 13093 Door User Defined 1 0.5000 0.5000 0.5000 ❑ Materials Used flat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu[ Iftl [Btu/h.ft.Fl [Ib/cf] [BtuAb.Fl 264 a o O.UU02 0.0050 26.0000 480.00 0.1000 L-i 214 Mat1214 POLYSTYRENE,EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/41N, 187 Mad 187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in.Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 81 Matl81 ASPHALT-ROOFING, Yes 0.1500 ❑ ROLL 91 Matl91 BUILDING PAPER, Yes 0.0600 ❑ PERMEABLE FELT 407 Mat1407 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ 80 Mat180 AIR LAYER,41N OR Yes 0.9200 ❑ MORE,HORIZ.ROOFS 245 Mat1245 PLYWOOD,5/81N No 0.7894 0.0521 0.0660 34.00 0.2900 ❑ 1001 ApLbMatl001 Outside surface resistance Yes 0.3300 ❑ 1002 ApLbMatl002 Inside surface resistance Yes 0.6900 ❑ 1003 ApLbMatl003 WOOD,SHINGLE,FOR No 0.8833 0.0583 0.0660 32.00 0.3000 ❑ WALL 1004 ApLbMat1004 R-22 Generic Insulation No 22.0000 0.4802 0.0218 0.30 0.2000 ❑ 12/13/2013 EnergyGauge Summit®v4.10 9 Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct lBtu/h.sf.Fl [Btu/sf.Fj lib/cfl lh.sLF/Btul 1002 Aluminum door, 1.25 in.polystyrene No No 0.19 0.53 43.67 5.2 ❑ Layer Material Material Thickness Framing No. R Factor 1 264 ALUMINUM, 1/16 IN 0.0050 0.000 ❑ 2 214 POLYSTYRENE,EXP., 1-1/41N, 0.1042 0.000 ❑ 3 264 ALUMINUM, 1/161N 0.0050 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct lBtu/h.sLFl JBtu/sf.Fl lib/cfl lh.sLF/Btul 1057 1 ft.soil,concrete floor,carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in.Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 12/13/2013 EnergyGauge Summit®v4.10 10 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sLF] [Ib/cf] [h.sLF/Btu] 1060 13093-Wall Assembly No No 0.05 1.52 10.32 22.2 ❑ Layer Material Material Thickness Framing No. IN Factor 1 1001 Outside surface resistance 0.000 ❑ 2 1003 WOOD,SHINGLE,FOR WALL 0.0583 0.000 ❑ 3 91 BUILDING PAPER,PERMEABLE FELT 0.000 ❑ 4 245 PLYWOOD,5/81N 0.0521 0.000 ❑ 5 407 R-19 Generic Insulation 0.4147 0.000 ❑ 6 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 7 1002 Inside surface resistance 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sLF] [Ib/cf] [h.sLF/Btu] 1061 Roof Assembly No No 0.04 1.20 11.06 25.3 ❑ Layer Material Material Thickness Framing No. [ft[ Factor 1 1001 Outside surface resistance 0.000 ❑ 2 4 Steel siding 0.0050 0.000 ❑ 3 81 ASPHALT-ROOFING,ROLL 0.000 ❑ 4 245 PLYWOOD,5/81N 0.0521 0.000 ❑ 5 1004 R-22 Generic Insulation 0.4802 0.000 ❑ 6 80 AIR LAYER,41N OR MORE,HORIZ. 0.000 ❑ ROOFS 7 187 GYP OR PLAS BOARD,I/2IN 0.0417 0.000 ❑ 8 1002 Inside surface resistance 0.000 ❑ 12/13/2013 EnergyGauge Summit®v4.10 l l 12/13/2013 EnergyGauge Summit®v4.10 12 Florida Energy Efficiency Code For Building Construction EnergyGauge SummitO Fla/Com-2010, Effective Date: March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: 13093 Description: Atlantic Beach Country Clulh Owner: Addressl: Enter Address here City: Atlantic Beach Address2: Enter Address here State: FL Zip: 32233 Type: Dining:Bar Lounge/Leisure Class: New Finished building Jurisdiction: DUVAL COUNTY,DUVAL COUNTY,FL(26 1000) Conditioned Area: 11138 SF Conditioned& UnConditioned Area: 11138 SF No of Stories: 1 Area entered from Plans 12211 SF Permit No: 0 Max Tonnage 14.5 If different,write in: Zzi 87 W10 M- EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 1 of 13 Compliance Summary Component Design Criteria Result Gross Energy Cost(in $) 7,668.0 8,029.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS Not Checked PIPING SYSTEMS PASSES Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 2 of 13 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code y� Prepared By: Michael Kratky Building Official: Date: Io2�/3 Zp 3 Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Susan Wood Date: If Required by Florida law, I hereby certify (")that the system design is in compliance with the Florida Energy Efficiency Code Architect: Cliff Duch Reg No: AR 0014227 Electrical Designer: Thomas C.Nielsen Reg No: 53492 Lighting Designer: Thomas C.Nielsen Reg No: 53492 Mechanical Designer: Farshid Yarizadeh Reg No: 40287 Plumbing Designer: Farshid Yarizadeh Reg No: 40287 (') Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 3 of 13 Project: 13093 Title: Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Building End Uses 1) Proposed 2) Baseline Total 481.90 630.80 $7,668 $10,036 ELECTRICITY(MBtu/kWh/$) 481.90 630.80 141216 184831 $7,668 $10,036 AREA LIGHTS 124.70 136.40 36529 39976 $1,984 $2,171 MISC EQUIPMT 83.80 83.80 24564 24564 $1,334 $1,334 PUMPS & MISC 1.00 1.20 304 359 $17 $19 SPACE COOL 179.70 186.30 52664 54576 $2,860 $2,963 SPACE HEAT 23.90 56.00 6993 16408 $380 $891 VENT FANS 68.80 167.10 20162 48948 $1,095 $2,658 Credits Applied: None PASSES Passing Criteria=8029 Design (including any credits)=7668 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 76.4% EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 4 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type:Dining:Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL ARPT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) Ext Light 1 Uncovered Parking Areas-- Yes 0.15 75,000.0 11,250 855 Parking lots and Drives Ext Light 3 Walk way less than 10 feet wide Yes 1.00 120.0 120 400 Ext Light 4 Special Feature areas Yes 0.20 21,000.0 4,200 520 Ext Light 5 Main entries Yes 30.00 6.0 180 30 Ext Light 6 Entry Canopies Yes 1.25 432.0 540 600 Ext Light 7 Other(doors)than main entries Yes 20.00 39.0 780 540 Ext Light 8 Other(doors)than main entries Yes 20.00 12.0 240 30 Ext Light 9 Other(doors)than main entries Yes 20.00 12.0 240 30 Ext Light 10 Canopies(freestanding,attached Yes 1.25 705.0 881 105 and Overhangs) Ext Light 11 Walkway less than 10 feet wide Yes 1.00 48.0 48 60 Ext Light 12 Building facades(by linear foot) No 5.00 58.0 290 120 Ext Light 13 Building facades(by linear foot) No 5.00 36.0 180 160 Tradable Surfaces: 3170 (VV)Allowance for Tradable: 9994.279 (W) PASSES All External Lighting: 3450 (W) Complicance check includes a excess/Base allowance of 600.00(W) Ext Light 13--70W from the excess/Base allowance was applied to this item to comply EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date. March 15,2012 12/13/2013 Page 5 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type:Dining:Bar Lounge/Leisure (WEA File:FL JACKSONVILLE INTL ARPT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance 003 1 Electrical Mechanical Equipment 51 1 1 PASSES Room-General 004 1 Electrical Mechanical Equipment 75 1 1 PASSES Room-General 111 7 Food Service-Kitchen 1,500 1 1 PASSES 111A 6 Toilet and Washroom 46 1 1 PASSES 113 17 Office-Enclosed 104 1 1 PASSES 115 7 Food Service-Kitchen 120 1 1 PASSES 104 5 Corridor 158 1 1 PASSES 109 5 Corridor 57 1 1 PASSES 110 3 Storage&Warehouse-Bulky 77 1 1 PASSES Active Storage 119 8 Food Service-Leisure Dining 1,303 3 1 PASSES 119 8 Food Service-Leisure Dining 559 3 1 PASSES 116 8 Food Service-Leisure Dining 710 1 1 PASSES 105 17 Office-Enclosed 128 1 1 PASSES 106 17 Office-Enclosed 128 1 1 PASSES 107 17 Office-Enclosed 128 1 1 PASSES 100 12 Lobby(General)-Reception and 280 2 1 PASSES Waiting 101 12 Lobby(General)-Reception and 214 1 1 PASSES Waiting 102 17 Office-Enclosed 150 1 1 PASSES 103 12 Lobby(General)-Reception and 151 2 1 PASSES Waiting 117 5 Corridor 62 1 1 PASSES 118 9 Food Service-Bar/Lounge 182 2 1 PASSES 119 9 Food Service-Bar/Lounge 92 1 1 PASSES 120 9 Food Service-Bar/Lounge 659 2 1 PASSES 120A 3 Storage&Warehouse-Bulky 59 1 1 PASSES Active Storage 120B 1 Electrical Mechanical Equipment 74 1 1 PASSES Room-General 121 9 Food Service-Bar/Lounge 782 1 1 PASSES 122 25,001 Sales Area 578 2 1 PASSES 123 17 Office-Enclosed 182 1 1 PASSES 123B 3 Storage&Warehouse-Bulky 40 1 1 PASSES Active Storage 125 5 Corridor 30 1 1 PASSES 126 5 Corridor 48 1 1 PASSES 127 8,002 Dressing/Locker/Fitting Room 307 1 1 PASSES (General) 128 6 Toilet and Washroom 410 2 1 PASSES 129 5 Corridor 72 1 1 PASSES 129A 1 Electrical Mechanical Equipment 28 1 1 PASSES Room-General EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date: March 15,2012 12/13/2013 Page 6 of 13 130 8,002 Dressing/Locker/Fitting Room 307 1 1 PASSES (General) 131 1 Electrical Mechanical Equipment 25 1 1 PASSES Room-General 132 6 Toilet and Washroom 614 2 1 PASSES 135 5 Corridor 40 1 1 PASSES 136 5 Corridor 125 1 1 PASSES 137 6 Toilet and Washroom 232 2 1 PASSES 138 6 Toilet and Washroom 214 2 1 PASSES 124 1 Electrical Mechanical Equipment 38 1 1 PASSES Room-General PASSES EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software.Effective Date: March 15,2012 12/13/2013 Page 7 of 13 Project: 13093 Title:Atlantic Beach Country Club—Main Building Type:Dining:Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL ARPT.tm3) System Report Compliance RTU-1 Packaged Roof Top Heat Pump System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 10.80 10.60 11.80 10.70 PASSES 135000 to 240000 Btu/h Clg Capacity Heating System Heat Pumps Air Cooled 3.30 3.20 PASSES (Heating Mode)> 135000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-2A Heat Pump Split System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.90 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 3.81 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-213 Heat Pump Split System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.90 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 8 of 13 Heating System Heat Pumps Air Cooled 3.81 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-3 Heat Pump Split System Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 8.50 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.70 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-4 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr l Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 9.00 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.53 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 9 of 13 AFI F-> Heat Pump Split System Constant Volume Packaged No. of Units System 1 Component Category CapacitN Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.70 10.60 12.00 10.70 PASSES 135000 to 240000 Btu/h Clg Capacity Heating System Heat Pumps Air Cooled 3.56 3.20 PASSES (Heating Mode)> 135000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.53 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-6 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 16.00 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 9.00 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.45 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) A I 1 F-7 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr l Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 8.50 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 10 of 13 Air Handling Air Handler(Supply)- 0.39 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) DSS-1 Ductless Split System Heat Pump Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 17.00 12.23 17.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 10.80 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.45 0.82 PASSES System-Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 13093 Title:Atlantic Beach Country Club—Main Building Type: Dining:Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL ARPT.tm3) Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance Water Heater 1 Gas Instantaneous Unknown 95.00 Not Checked water heater Not Checked EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 11 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type:Dining: Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] [F] .SF.F] Domestic and Service Hot Water 1.50 False 140.00 0.28 1.50 1.00 PASSES Systems Domestic and Service Hot Water 1.50 False 120.00 0.28 1.50 1.00 PASSES Systems PASSES EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 12 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type:Dining:Bar Lounge/Leisure (WEA File:FL JACKSONVILLE_INTL ARPT.tm3) Other Required Compliance Category Section Requirement(write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfin/ft2;all EM other products:0.3 cfin/ftz Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed Dropped Ceiling 502.3 Vented:seal&insulated ceiling.Unvented seal&insulate roof& 1A Cavity side walls HVAC Efficiency 503.2.3 Minimum efficiencies:Tables 503.2.3(1)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers F shall be mechanically attached,sealed,insulated&installed per Table 503.2.7.2.Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in El construction documents. Piping Insulation 503.2.8 RAC and service hot water.In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat FA trap required. Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce ❑ heat loss on heated pools;Time switch(exceptions);readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met F] Lighting Controls 505.2,502.3 Automatic control required for interior lighting in buildings Q >5,000 s.f.;Space control;Exterior photo sensor;Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 13 of 13 EnergyGauge Summit®v4.10 INPUT DATA REPORT Proiect Information Project Name: 13093 Orientation: North Project Title: Atlantic Beach Country Club—Main Building Building Type: Dining: Bar Lounge/Leisure Address: Enter Address here Building Classification: New Finished building Enter Address here State: FL No.of Stories: 1 Zip: 32233 GrossArea: 11138 SF Owner: Zones No Acronym Description Type Area Multiplier Total Area lsl1 [Sf1 1 Zone 1 Kitchen CONDITIONED 1896.0 1 1896.0 ❑ 2 Zone 2A Hall(East) CONDITIONED 1595.2 1 1595.2 ❑ 3 Zone 2B Dining Hall(West) CONDITIONED 1268.6 1 1268.6 ❑ 4 Zone3 Offices CONDITIONED 383.7 1 383.7 ❑ 5 Zone 4 Reception CONDITIONED 795.0 1 795.0 ❑ 6 Zone 5 Bar CONDITIONED 1909.9 1 1909.9 ❑ 12/13/2013 EnergyGauge Summit®v4.10 1 ti 7 Zone 6 Pro Shop CONDITIONED 829.9 1 829.9 ❑ 8 Zone 7 Locker Rooms CONDITIONED 2421.9 1 2421.9 ❑ 9 Zone 8 IT Room CONDITIONED 38.0 1 38.0 ❑ Spaces No AcronN ni Description Type Depth Width Height Multi Total Area Total Volume [ftp ifti [ft] plier [sf] jcfj In Zone: Zone 1 1 003 Electrical Service Electrical Mechanical 7.14 7.14 9.00 1 51.0 458.8 ❑ Equipment Room-General 2 004 Mechanical Service Electrical Mechanical 8.66 8.66 9.00 1 75.0 675.0 ❑ Equipment Room-General 3 111 Kitchen Food Service-Kitchen 38.73 38.73 9.00 1 1500.0 13500.1 ❑ 4 111A Restroom Toilet and Washroom 6.78 6.78 9.00 1 46.0 413.7 ❑ 5 113 Office Office-Enclosed 10.20 10.20 9.00 1 104.0 936.4 ❑ 6 115 Food Service Food Service-Kitchen 10.96 10.95 9.00 1 120.0 1080.1 ❑ In Zone: Zone 2A 1 104 Gallery Corridor 26.33 6.00 11.33 1 158.0 1789.9 ❑ 2 109 Hall Corridor 9.50 6.00 11.33 1 57.0 645.8 ❑ 3 110 Table Storage Storage&Warehouse- 8.78 8.77 11.33 1 77.0 872.4 ❑ Bulky Active Storage 4 119 Dining Hall (70%) Food Service-Leisure 36.10 36.10 22.50 1 1303.2 29322.2 ❑ Dining In Zone: Zone 2B l 119 Dining Hall(30%) Food Service-Leisure 23.64 23.63 22.50 1 558.6 12568.8 ❑ Dining 2 116 Dining Loggia Food Service-Leisure 26.65 26.64 11.33 1 710.0 8043.8 ❑ Dining In Zone: Zone3 1 105 Club Manager's Office Office-Enclosed 11.31 11.31 11.33 1 127.9 1449.3 ❑ 2 106 Asstent Manager's Office-Enclosed 11.31 11.31 11.33 1 127.9 1449.3 ❑ Office 3 107 Accounting Office Office-Enclosed 11.31 11.31 11.33 1 127.9 1449.3 ❑ 12/13/2013 EnergyGauge Summit®v4.10 2 1 In Zone: Zone 1 100 Foyer Lobby(General)-Reception 16.73 16.73 11.33 1 279.9 3171.2 ❑ and Waiting 2 101 Reception Lobby(General)-Reception 14.63 14.63 11.33 1 214.0 2425.0 ❑ and Waiting 3 102 Membership Office Office-Enclosed 12.25 12.25 11.33 1 150.1 1700.2 ❑ 4 103 Waiting Aera Lobby(General)-Reception 12.29 12.29 11.33 1 151.0 171 1.3 ❑ and Waiting In 'Lone: Zone 5 1 117 Vestibule Corridor 7.88 7.87 11.33 1 62.0 702.6 ❑ 2 118 Dining Vestibule Food Service-Bar/Lounge 13.49 13.49 11.33 1 182.0 2061.8 ❑ 3 119 Service Station Food Service-Bar/Lounge 9.59 9.59 11.33 1 92.0 1042.0 ❑ 4 120 Bar Food Service-Bar/Lounge 25.67 25.67 9.00 1 658.9 5930.5 ❑ 5 120A Liquor Storage and Storage&Warehouse- 7.68 7.68 9.00 1 59.0 530.8 ❑ Cooler Bulky Active Storage 6 120B Mechanical Electrical Mechanical 8.60 8.60 9.00 1 74.0 665.6 ❑ Equipment Room-General 7 121 Grill Food Service-Bar/Lounge 27.97 27.96 9.00 1 782.0 7038.4 ❑ In Zone: Zone 6 1 122 Golf Pro Shop Sales Area 24.04 24.04 11.33 1 577.9 6547.9 ❑ 2 123 Pro Shop Office Office-Enclosed 13.49 13.49 9.00 1 182.0 1637.8 ❑ 3 123B Merchandise Storage Storage&Warehouse- 6.33 6.32 9.00 1 40.0 360.1 ❑ Bulky Active Storage 4 125 Men's Entry Corridor 5.48 5.48 9.00 1 30.0 270.3 ❑ In Zone: Zone 7 1 126 Hall Corridor 6.93 6.93 9.00 1 48.0 432.2 ❑ 2 127 Men's Lockers Dressing/Locker/Fitting 17.52 17.52 9.00 1 307.0 2762.6 ❑ Room(General) 3 128 Men's Private Restroom Toilet and Washroom 20.25 20.25 9.00 1 410.1 3690.6 ❑ 4 129 Vestibule Corridor 8.49 8.48 9.00 1 72.0 648.0 ❑ 5 129A Mechanical Electrical Mechanical 5.29 5.29 9.00 1 28.0 251.9 ❑ Equipment Room-General 6 130 Women's Lockers Dressing/Locker/Fitting 17.52 17.52 9.00 1 307.0 2762.6 ❑ Room(General) 12/13/2013 EnergyGauge Summit®v4.10 3 r 7 131 FDC/Riser Electrical Mechanical 5.00 5.00 9.00 1 25.0 225.0 Equipment Room-General 8 132 Women's Restroom Toilet and Washroom 24.78 24.78 9.00 1 614.0 5526.4 E] 9 135 Vestibule Corridor 6.32 6.32 9.00 1 39.9 359.5 E] 10 136 Hall Corridor 11.18 11.18 9.00 1 125.0 1124.9 11 137 Women's Restroom Toilet and Washroom 15.23 15.23 9.00 1 232.0 2087.6 El 12 138 Men's Restroom Toilet and Washroom 14.63 14.63 9.00 1 214.0 1926.3 In Zone: Zone 8 1 124 Tehnical Closet Electrical Mechanical 6.17 6.16 9.00 1 38.0 342.1 El Equipment Room-General Lighting No Type Category No.of Watts per Power Control Type No.of Luminaires Luminaire I W I Ctrl pts In Zone: Zone 1 In Space: 003 1 Suspended Fluorescent General Lighting 1 58 58 Manual On/Off I ❑ In Space: 004 1 Compact Fluorescent General Lighting 1 58 58 Manual On/Off 1 In Space: 111 1 Compact Fluorescent General Lighting 17 88 1496 Manual On/Off 1 In Space: 111A 1 Recessed Fluorescent- General Lighting 1 58 58 Manual On/Off I No vent In Space: 113 1 Recessed Fluorescent- General Lighting 2 88 176 Manual On/Off 1 No vent In Space: 115 1 Recessed Fluorescent- General Lighting 3 88 264 Manual On/Off 1 No vent In Zone: Zone 2A In Space: 104 1 LED General Lighting 6 15 90 Manual On/Off I ❑ 12/13/2013 EnergyGauge Summit®v4.10 4 In Space: 109 1 LED General Lighting 2 15 30 Manual On/Off In Space: 110 1 Suspended Fluorescent General Lighting 1 88 88 Manual On/Off 1 EJ In Space: 119 1 Suspended Fluorescent General Lighting 2 600 1200 Manual On/Off 1 2 Suspended Fluorescent General Lighting 6 60 360 Manual On/Off 1 3 LED General Lighting 9 30 270 Manual On/Off 1 E-1 In "Lone: Zone 2B In Space: 119 1 Suspended Fluorescent General Lighting 1 600 600 Manual On/Off 1 2 Suspended Fluorescent General Lighting 2 60 120 Manual On/Off 1 El 3 LED General Lighting 4 30 120 Manual On/Off I E] In Space: 116 1 Suspended Fluorescent General Lighting 5 300 1500 Manual On/Off I E] In Zone: Zone3 In Space: 105 1 Recessed Fluorescent- General Lighting 2 58 116 Manual On/Off 1 El No vent In Space: 106 1 Recessed Fluorescent- General Lighting 2 58 116 Manual On/Off I El No vent In Space: 107 1 Recessed Fluorescent- General Lighting 2 58 116 Manual On/Off 1 EJ No vent In Zone: Zone 4 In Space: 100 1 Suspended Fluorescent General Lighting 1 600 600 Manual On/Off 1 2 Suspended Fluorescent General Lighting 4 60 240 Manual On/Off 1 El In Space: 101 1 LED General Lighting 5 15 75 Manual On/Off I In Space: 102 1 Recessed Fluorescent- General Lighting 2 58 116 Manual On/Off 1 El No vent In Space: 103 12/13/2013 EnergyGauge Summit®v4.10 S I LED General Lighting 2 15 30 Manual On/Off 1 2 Suspended Fluorescent General Lighting 2 40 80 Manual On/Off 1 In Zone: Zone 5 In Space: 117 1 LED General Lighting 1 15 15 Manual On/Off 1 In Space: 118 1 Suspended Fluorescent General Lighting 1 300 300 Manual On/Off 1 2 Suspended Fluorescent General Lighting 4 60 240 Manual On/Off 1 In Space: 119 1 LED General Lighting 1 15 15 Manual On/Off 1 In Space: 120 1 LED General Lighting 18 15 270 Manual On/Off 1 2 Suspended Fluorescent General Lighting 2 60 120 Manual On/Off 1 ❑ In Space: 120A 1 LED General Lighting 2 15 30 Manual On/Off 1 ❑ In Space: 120B 1 LED General Lighting 2 15 30 Manual On/Off 1 In Space: 121 1 LED General Lighting 16 15 240 Manual On/Off In Zone: Zone 6 In Space: 122 1 LED General Lighting 12 30 360 Manual On/Off I ❑ 2 Suspended Fluorescent General Lighting 1 300 300 Manual On/Off In Space: 123 1 LED General Lighting 6 15 90 Manual On/Off 1 In Space: 123B 1 Suspended Fluorescent General Lighting 1 58 58 Manual On/Off 1 ❑ In Space: 125 1 LED General Lighting 1 15 15 Manual On/Off I El In Zone: Zone 7 In Space: 126 1 LED General Lighting 1 15 15 Manual On/Off 1 ❑ In Space: 127 12/13/2013 EnergyGauge Summit®v4.10 6 1 LED General Lighting 10 15 150 Manual On/Off 1 In Space: 128 1 LED General Lighting 13 15 195 Manual On/Off 2 Suspended Fluorescent General Lighting 3 40 120 Manual On/Off I E] In Space: 129 1 LED General Lighting 1 15 15 Manual On/Off 1 El In Space: 129A 1 Suspended Fluorescent General Lighting 1 40 40 Manual On/Off I In Space: 130 1 LED General Lighting 6 15 90 Manual On/Off 1 In Space: 131 1 Suspended Fluorescent General Lighting 1 40 40 Manual On/Off In Space: 132 1 LED General Lighting 16 15 240 Manual On/Off 1 El 2 Suspended Fluorescent General Lighting 11 40 440 Manual On/Off In Space: 135 1 LED General Lighting 1 15 15 Manual On/Off 1 In Space: 136 1 LED General Lighting 3 15 45 Manual On/Off I El In Space: 137 1 LED General Lighting 6 15 90 Manual On/Off 1 2 Suspended Fluorescent General Lighting 3 40 120 Manual On/Off 1 El In Space: 138 1 LED General Lighting 5 15 75 Manual On/Off 1 El 2 Suspended Fluorescent General Lighting 3 40 120 Manual On/Off 1 E] In Zone: Zone 8 In Space: 124 1 Recessed Fluorescent- General Lighting 1 58 58 Manual On/Off I E] No vent 12/13/2013 EnergyGauge Summit®v4.10 7 Walls \o Description Type Width H(Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sfl [Btu/hr.sf.F] Capacity [lb/cfJ [h.sf.F/Btu] [Btu/sf.F] In "Lone: Lone 1 1 N Wall Assembly 13093-Wall 48.67 9.00 I 438.0 North 0.0450 1.515 10.32 22.2 ❑ Assembly 2 E Wall assembly 13093-Wall 26.67 9.00 1 240.0 East 0.0450 1.515 10.32 22.2 ❑ Assembly 3 S Wall Assembly 13093-Wall 9.17 9.00 1 82.5 South 0.0450 1.515 10.32 22.2 ❑ Assembly 4 W Wall Assembly 13093-Wall 26.67 9.00 1 240.0 West 0.0450 1.515 10.32 22.2 ❑ Assembly In Zone: Zone 2A I E Wall Assembly 13093-Wall 5.33 19.17 1 102.2 East 0.0450 1.515 10.32 22.2 ❑ Assembly In Zone: Zone 2B 1 Upper W Wall Assembly 13093-Wall 5.33 19.17 1 102.2 West 0.0450 1.515 10.32 22.2 ❑ Assembly 2 W Wall Assembly 13093-Wall 58.75 11.33 1 665.6 West 0.0450 1.515 10.32 22.2 ❑ Assembly In Zone: Zone3 1 N Wall Asembly 13093-Wall 1.25 11.33 1 14.2 North 0.0450 1.515 10.32 22.2 ❑ Assembly 2 E Wall Assembly 13093-Wall 34.00 11.33 1 385.2 East 0.0450 1.515 10.32 22.2 ❑ Assembly 3 S Wall Assembly 13093-Wall 4.58 11.33 1 51.9 South 0.0450 1.515 10.32 ❑ Assembly In Zone: Zone 4 1 N Wall Assmbly 13093-Wall 16.83 11.33 1 190.7 North 0.0450 1.515 10.32 22.2 ❑ Assembly 2 E Wall Assembly 13093-Wall 46.00 11.33 1 521.2 East 0.0450 1.515 10.32 22.2 ❑ Assembly 3 S Wall Assmbly 13093-Wall 16.83 11.33 1 190.7 South 0.0450 1.515 10.32 22.2 ❑ Assembly In Zone: Zone 5 1 N Wall Assembly 13093-Wall 18.50 9.00 1 166.5 North 0.0450 1.515 10.32 22.2 ❑ Assembly 12/13/2013 EnergyGauge Summit®v4.10 8 2 NW Wall Assembly 13093-Wall 18.83 9.00 1 169.5 NorthWes 0.0450 1.515 10.32 22.2 ❑ Assembly t 3 W Wall Assembly 13093-Wall 18.50 9.00 1 166.5 West 0.0450 1.515 10.32 22.2 ❑ Assembly I n Zone: Zone 6 1 N Wall Assembly 13093-Wall 6.67 11.33 1 75.6 North 0.0450 1.515 10.32 22.2 ❑ Assembly 2 W Wall Assembly 13093-Wall 26.75 11.33 1 303.1 West 0.0450 1.515 10.32 22.2 ❑ Assembly 3 S Wall Assembly 13093-Wall 31.33 11.33 1 355.0 South 0.0450 1.515 10.32 22.2 ❑ Assembly In Zone: Zone 7 1 N Wall Assembly 13093-Wall 3.42 9.00 1 30.8 North 0.0450 1.515 10.32 22.2 ❑ Assembly 2 E Wall assembly 13093-Wall 35.42 9.00 1 318.8 East 0.0450 1.515 10.32 22.2 ❑ Assembly 3 S Wall Assembly 13093-Wall 67.67 9.00 1 609.0 South 0.0450 1.515 10.32 22.2 ❑ Assembly 4 W Wall Assembly 13093-Wall 8.00 9.00 1 72.0 West 0.0450 1.515 10.32 22.2 ❑ Assembly Windows No Description Type Shaded 11 SI IGC Vis.Tra W H(Effec) Multi Total Area IBtu/hrsfFl IN [ft] plier [sf] In Zone: Zone 1 In Wall: E Wall 1 24x24 Window User Defined No 0.4000 0.40 0.40 2.00 2.00 4 16.0 2 24x50 Window User Defined No 0.4000 0.40 0.40 2.00 4.17 4 33.4 In Wall: S Wall 1 24x24 Window User Defined No 0.4000 0.40 0.40 2.00 2.00 1 4.0 ❑ In Wall: W Wall 1 30x80 Window User Defined No 0.4000 0.40 0.40 2.50 6.67 1 16.7 ❑ 2 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 2 33.4 ❑ Window In Zone: Zone 2A In Wall: E Wall 1 30x50 Window User Defined No 0.4000 0.40 0.40 2.50 4.17 5 52.1 12/13/2013 EnergyGauge Summit®v4.10 9 In Zone: Zone 2B In Wall: W Wall 1 30x80 Window User Defined No 0.4000 0.40 0.40 2.50 6.67 6 100.1 ❑ 2 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 9 150.1 ❑ Window In Wall: W Wall Upper 1 3000 Window User Defined No 0.4000 0.40 0.40 2.50 4.17 5 52.1 In Zone: Zone 4 In Wall: E Wall 1 24x24 Window User Defined No 0.4000 0.40 0.40 2.00 2.00 1 4.0 2 30x60 Window User Defined No 0.4000 0.40 0.40 2.50 5.00 1 12.5 3 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 2 33.4 Window 4 16x80 Window User Defined No 0.4000 0.40 0.40 1.33 6.67 2 17.7 ❑ In Wall: N Wall 1 28x50 Window User Defined No 0.4000 0.40 0.40 2.33 4.17 2 19.4 In Wall: S Wall 1 28x50 Window User Defined No 0.4000 0.40 0.40 2.33 4.17 2 19.4 ❑ In Zone: Zone 5 In Wall: N Wall 1 30x66 Window User Defined Yes 0.4000 0.40 0.40 2.50 5.50 1 13.8 2 56x66 Window User Defined Yes 0.4000 0.40 0.40 4.67 5.50 2 51.4 ❑ In Wall: NW Wall 2 56x66 Window User Defined Yes 0.4000 0.40 0.40 4.67 5.50 2 51.4 ❑ 3 26x80 Door User Defined Yes 0.4000 0.40 0.40 2.17 6.67 2 28.9 Window In Wall: W Wall 1 30x66 Window User Defined Yes 0.4000 0.40 0.40 2.50 5.50 1 13.8 2 56x66 Window User Defined Yes 0.4000 0.40 0.40 4.67 5.50 2 51.4 ❑ In Zone: Zone 6 In Wall: N Wall 1 30x80 Window User Defined No 0.4000 0.40 0.40 2.50 6.67 1 16.7 In Wall: S Wall 1 30x80 Window User Defined No 0.4000 0.40 0.40 2.50 6.67 1 16.7 2 30x60 Window User Defined Yes 0.4000 0.40 0.40 2.50 5.00 1 12.5 ❑ 3 30x80 Door User Defined Yes 0.5000 0.50 0.50 2.50 6.67 2 33.4 El Window In Wall: W Wall 1 30x80 Door User Defined No 0.5000 0.50 0.50 2.50 6.67 2 33.4 Window 12/13/2013 EnergyGauge Summit®v4.10 10 In Zone: Zone 7 I n Wall: E Wall 1 24x24 Window User Defined No 0.4000 0.40 0.40 2.00 2.00 4 16.0 ❑ 2 24x50 Window User Defined No 0.4000 0.40 0.40 2.00 4.17 4 33.4 ❑ In Wall: S Wall 1 30x60 Window User Defined Yes 0.4000 0.40 0.40 2.50 5.00 2 25.0 ❑ 2 3000 Window User Defined No 0.4000 0.40 0.40 2.50 2.50 3 18.8 ❑ In Wall: W Wall 1 30x80 Door User Defined Yes 0.5000 0.50 0.50 2.50 6.67 1 16.7 ❑ Window In Zone: Zone3 In Wall: E Wall 1 30x60 Window User Defined No 0.4000 0.40 0.40 2.50 5.00 3 37.5 ❑ In Wall: S Wall 1 26x60 Window User Defined No 0.4000 0.40 0.40 2.17 5.00 1 10.9 ❑ Doors No Description Type Shaded? Width H(Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr.sf.F] [Ib/cf] [Btu/sf.F] [h.sf.FBtu] In Zone: Zone 1 In Wall: N Wall 1 PrOZolWalDrl Solid core flush Yes ,.00 7.50 1 22.5 0.3504 0.00 0.00 2.85 ❑ (2.25) Roofs No Description Type Width H(Effec) Multi Are;i Tilt Cond. Heat Cap Dens. R-Value IN IN plier ]sfj [deg] [Btu/hr. Sf.F] [Btu/sf.F] [Ib/cf] [h.sf.F/Btu] In Zone: Zone 1 1 zone 1 Roof Roof Assembly 43.54 43.54 1 1895.7 0.00 0.0395 1.20 11.06 25.3 ❑ Assembly 1 n 7,one: Zone 2A 1 Zone 2A Roof Roof Assembly 39.94 39.94 1 1595.2 0.00 0.0395 1.20 11.06 ?5.. ❑ Assembly I n Zone: Zone 2B 12/13/2013 EnergyGauge Summit®v4.10 11 I Zone 213 Roof Roof Assembly 35.62 35.62 1 1268.8 0.00 0.0395 1-10 11.06 3 ❑ Assembly In Zone: Zone3 1 Zone 3 Roof Roof Assembly 19.59 19.59 1 383.8 0.00 0.0395 1.20 11.06 2 5.3 ❑ Assembly In Zone: Zone 4 1 Zone 4 Roof Roof Assembly 28.19 28.20 1 795.0 0.00 0.0395 1.20 11.06 25.3 ❑ Assembly 1 n Zone: Zone 5 1 Zone 5 Roof Roof Assembly 43.70 43.70 1 1909.7 0.00 0.0395 1.20 11.06 25.3 ❑ Assembly In "Lone: Zone 6 1 Zone 6 Roof Roof Assembly 28.81 28.81 1 830.0 0.00 0.0395 1.20 11.06 25.3 ❑ Assembly In "Zone: Zone 7 1 Zone 7 Roof Roof Assembly 49.21 49.21 1 2421.6 0.00 0.0395 1.20 11.06 25.3 ❑ Assembly In Zone: Zone 8 1 Zone 8 Roof Roof Assembly 6.16 6.17 1 38.0 0.00 0.0395 1.20 11.06 25.3 ❑ Assembly Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sfl [Sf] In "Zone: In Roof: El Floors No Description Type Width 11 (Effec) Nlulti Area Cond. Heat Cap. Dens. R-Value IN Iftl plier 141 [Btuihr. sf. Fj [Btu/sf.F] [Ib/cf] [h.sf.FBtu] In Zone: Zone 1 I Zone 1 Floor 1 ft.soil,concrete 43.54 43.54 1 1895.7 0.2681 34.00 113.33 3.73 ❑ Assembly floor,carpet and rubber pad 12/13/2013 EnergyGauge Summit®v4.10 12 In Zone: Zone 2A 1 Zone 2A Floor 1 ft.soil,concrete 39.94 39.94 1 1595.2 0.2681 34.00 1 13.33 3.73 ❑ Assembly floor,carpet and rubber pad In Zone: Zone 2B 1 Zone 2B Floor 1 ft.soil,concrete 35.62 35.62 1 1268.8 0.2681 34.00 113.33 3.7 3 0 Assembly floor,carpet and rubber pad hi Zone3 1 Zone 3 Floor 1 ft.soil,concrete 19.59 19.59 1 383.8 0.2681 34.00 11 33 3.73 ❑ Assembly floor,carpet and rubber pad In /.one: Zone 4 1 Zone 4 Floor 1 ft.soil,concrete 28.19 28.20 1 795.0 0.2681 34.00 113.:3 3.73 ❑ Assembly floor,carpet and rubber pad In Zone: Zone 5 1 Zone 5 Floor 1 ft.soil,concrete 43.70 43.70 1 1909.7 0.2681 34.00 113.33 3.7; ❑ Assembly floor,carpet and rubber pad In "Zone: Zone 6 1 Zone 6 Floor 1 ft.soil,concrete 28.81 28.81 1 830.0 0.2681 34.00 113.33 3.73 ❑ Assembly floor,carpet and rubber pad In "Zone: Zone 7 1 Zone 7 Floor 1 ft.soil,concrete 49.21 49.21 1 2421.6 0.2681 34.00 113.33 3.73 ❑ floor,carpet and rubber pad In Zone: Zone 8 I Zone 8 Floor 1 ft.soil,concrete 6.16 6.17 1 38.0 0.2681 34.00 113.3 3.73 ❑ floor,carpet and rubber pad Systems RTU-1 Packaged Roof Top Heat Pump System Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 174310.00 10.80 11.80 ❑ 12/13/2013 EnergyGauge Summit®v4.10 13 2 Heating System 166050.00 3.30 0 3 Air Handling System-Supply 5250.00 0.42 ❑ 4 Air Distribution System(Sup) 6.00 E:1 5 Air Distribution System(Ret) 6.00 ❑ AHU-2A Heat Pump Split System Constant Volume Packaged System No. Of Units l Component Category Capacity Efficiency IPLV I Cooling System 108250.00 11.90 12.00 1:1 2 Heating System 128700.00 3.81 El 3 Air Handling System-Supply 3500.00 0.42 F-1 4 Air Distribution System(Sup) 6.00 ❑ 5 Air Distribution System(Ret) 6.00 ❑ AHU-213 Heat Pump Split System Constant Volume Pacl:aged System No. Of Units l Component Category Capacity Efficiency IPLV 1 Cooling System 108250.00 11.90 12.00 E:1 2 Heating System 128700.00 3.81 ❑ 3 Air Handling System-Supply 3500.00 0.42 ❑ 4 Air Distribution System(Sup) 6.00 ❑ 5 Air Distribution System(Ret) 6.00 ID AHU-3 Heat Pump Split System Constant Volume Air Cooled Split No.Of Units l System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 15990.00 15.50 16.00 ❑ 2 Heating System 17560.00 8.50 ❑ 3 Air Handling System-Supply 525.00 0.70 ❑ 4 Air Distribution System(Sup) 6.00 ❑ 5 Air Distribution System(Ret) 6.00 ❑ 12/13/2013 EnergyGauge Summit®v4.10 14 L AHU-4 Heat Pump Split System Constant Volume Air Cooled Split No. Of Units 1 System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 32310.00 15.50 16.00 EJ 2 Heating System 33870.00 9.00 E] 3 Air Handling System-Supply 1050.00 0.53 4 Air Distribution System(Sup) 6.00 5 Air Distribution System(Ret) 6.00 Q AHU-5 Heat Pump Split System Constant Volume Packaged System No. Of Units l Component Category Capacity Efficiency IPLV 1 Cooling System 146230.00 11.70 12.00 E] 2 Heating System 176000.00 3.56 F-1 3 Air Handling System-Supply 4200.00 0.53 E 4 Air Distribution System(Sup) 6.00 E:1 5 Air Distribution System(Ret) 6.00 AHLJ-6 Heat Pump Split System Constant Volume Air Cooled Split No. Of Units 1 System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 39250.00 16.00 16.00 EJ 2 Heating System 41050.00 9.00 3 Air Handling System-Supply 1225.00 0.45 4 Air Distribution System(Sup) 6.00 5 Air Distribution System(Ret) 6.00 El 12/13/2013 EnergyGauge Summit®v4.10 15 AHU-7 Heat Pump Split System Constant Volume Air Cooled Split No. Of Units 1 System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 42710.00 15.50 16.00 ❑ 2 Heating System 45010.00 8.50 ❑ 3 Air Handling System-Supply 1400.00 0.39 ❑ 4 Air Distribution System(Sup) 6.00 ❑ 5 Air Distribution System(Ret) 6.00 ❑ DSS-1 Ductless Split System Heat Pump Constant Volume Air Cooled Split No. Of Units l System<65000 Btu/hr Component Category Capacity Efficiency 1PLV 1 Cooling System 17000.00 17.00 17.00 ❑ 2 Heating System 19000.00 10.80 ❑ 3 Air Handling System-Supply 410.00 0.45 ❑ Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description C.1pacit)Ca1).C11it 1/PRt. Efficiency Loss 1 Gas Instantaneous water heater [Gal] 199000 [Btu/h] 95.0000 [Ef/]Et] [Btuih] ❑ Ext-Lighting Description Category No.of Watts per Area/Len/No.of units Control Type Wattage Luminaires Luminaire Isf/ft/Nol [W] 1 Ext Light 1 Uncovered Parking Areas-- 9 95 75000.00 Astronomical Timer Coi 855.00 ❑ Parking lots and Drives 12/13/2013 EnergyGauge Summit®v4.10 16 Ext Light 3 Walk way less than 10 feet 1 400 120.00 Astronomical Timer Coi 400.00 ❑ wide Ext Light 4 Special Feature areas 8 65 21000.00 Astronomical Timer Coi 520.00 ❑ 1 Ext Light 5 Main entries 2 15 6.00 Astronomical Timer Coi 30.00 ❑ 5 Ext Light 6 Entry Canopies 1 600 432.00 Astronomical Timer Col 600.00 ❑ 6 Ext Light 7 Other(doors)than main 9 60 39.00 Astronomical Timer Coi 540.00 ❑ entries 7 Ext Light 8 Other(doors)than main 2 15 12.00 Astronomical Timer Coi 30.00 ❑ entries S Ext Light 9 Other(doors)than main 1 30 12.00 Astronomical Timer Coi 30.00 ❑ entries 9 Ext Light 10 Canopies(freestanding, 7 15 705.00 Astronomical Timer Coj 105.00 ❑ attached and Overhangs) 10 Ext Light 11 Walkway less than 10 feet 1 60 48.00 Astronomical Timer Coi 60.00 ❑ wide I 1 Ext Light 12 Building facades(by linear 2 60 58.00 Astronomical Timer Coj 120.00 ❑ foot) 12 Ext Light 13 Building facades(by linear 2 80 36.00 Astronomical Timer Coi 160.00 ❑ foot) Piping No TypeOperating Insulation Nomonal pipe Insulation is Runout? "Temperature Conductivity Diameter Thickness IFI [Btu-in/h.sf.F] [in] [in] 1 Domestic and Service Hot Water Systems 140.00 0.28 1.50 1.50 No ❑ 2 Domestic and Service Hot Water Systems 120.00 0.28 1.50 1.50 No ❑ Fenestration Used Name Glass Type No.of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] 13093 Window User Defined 1 0.4000 0.4000 0.4000 ❑ 13093 Door User Defined 1 0.5000 0.5000 0.5000 ❑ 12/13/2013 EnergyGauge Summit®v4.10 17 13093 Storefront User Defined 1 0.4000 0.4000 0.4000 ❑ Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] [ft] [Btu/h.ft.Fl [lb/cf] [Btu/lb.F] 187 a o 0.4533 0.0417 0.0920 50.0U U.2000 L-i BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in.Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 81 Matl81 ASPHALT-ROOFING, Yes 0.1500 ❑ ROLL 91 Matl91 BUILDING PAPER, Yes 0.0600 ❑ PERMEABLE FELT 407 Mat1407 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ 80 Mat180 AIR LAYER,4IN OR Yes 0.9200 ❑ MORE,HORIZ.ROOFS 245 Matl245 PLYWOOD,5/81N No 0.7894 0.0521 0.0660 34.00 0.2900 ❑ 1001 ApLbMatl001 Outside surface resistance Yes 0.3300 ❑ 1002 ApLbMat1002 Inside surface resistance Yes 0.6900 ❑ 1003 ApLbMat1003 WOOD,SHINGLE,FOR No 0.8833 0.0583 0.0660 32.00 0.3000 ❑ WALL 1004 ApLbMatl004 R-22 Generic Insulation No 22.0000 0.4802 0.0218 0.30 0.2000 ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1057 1 ft. soil,concrete floor,carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 12/13/2013 EnergyGauge Summit®v4.10 18 No 'Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/c4 [h.sf.FBtu] 1057 1 ft.soil,concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 2 48 6 in.Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.FI [lb/cf] [h.sf.F/Btu] 1058 Solid core flush(2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 279 Solid core flush(2.25") 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.FBtul 1060 13093-Wall Assembly No No 0.05 1.52 10.32 22.2 ❑ Laver Material Material Thickness Framing No. [ft] Factor 1 1001 Outside surface resistance 0.000 ❑ 2 1003 WOOD,SHINGLE,FOR WALL 0.0583 0.000 ❑ 3 91 BUILDING PAPER,PERMEABLE FELT 0.000 ❑ 4 245 PLYWOOD,5/81N 0.0521 0.000 ❑ 5 407 R-19 Generic Insulation 0.4147 0.000 ❑ 6 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 7 1002 Inside surface resistance 0.000 ❑ 12/13/2013 EnergyGauge Summit®v4.10 19 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sEF] IIb/cfl ]h.sLF/Btu] 1061 Roof Assembly No No 0.04 1.20 11.06 25.3 ❑ Layer Material Material Thickness Framing No. IN Factor 1 1001 Outside surface resistance 0.000 ❑ 2 4 Steel siding 0.0050 0.000 ❑ 3 81 ASPHALT-ROOFING,ROLL 0.000 ❑ 4 245 PLYWOOD,518IN 0.0521 0.000 ❑ 5 1004 R-22 Generic Insulation 0.4802 0.000 ❑ 6 80 AIR LAYER,41N OR MORE,HORIZ. 0.000 ❑ ROOFS 7 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 8 1002 Inside surface resistance 0.000 ❑ 12/13/2013 EnergyGauge Summit®v4.10 20 rs�-�`�,�yCity of Atlantic Beach Building Department APPLICATION NUMBER (To be assigned by the Building Department.) 800 Seminole Road i,rr 18 2013 Atlantic Beach, Florida 32233-5445 - Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: /z 1 City web-site: http://www.coab.us 13 ------Jl APPLICATION REVIEW AND TRACKING FORM Property Address: QQ JJIV*A-'.Jh&?Zj?7 A 1� De artmentreview required Yes No A ui Applicant: l Zoning ed-Admirns rator Project: !�V �2) ublic Works u lic Utilities • 1v O—, d pcn-i r ublic Safety Fire Services Review fee $ Dept sigpatur ', Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: JNApproved. ❑Denied. (Circle one.) Comments: BUILDING ICA);4*0 PLANNING &ZONING Reviewed by: Date: ZZ-2-0-8-- TREE Z-2-0`8TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. Comments: IL PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: _ V Reviewed by: Date: Revised 05/14/09 PUBLIC UTILITIES PLAN REVIEW COMMENTS Initials: Date: Project dame/Address: ( a ��/v /1 ✓' Application Permit#: Check Box Check to Add Box to Application Tracking Comments Comment "Print" UWSU Avoid damage to underground water/sewer utilities. Verify vertical and horizontalI;d it location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. MBSC Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. RTIC A sewer cleanout must be installed at the property line. Cleanout must be covered with ❑ ❑ an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. RPZB A reduced pressure zone backflow preventer must be installed if irrigation will be provided or if there is a private well on the property. Backflow preventer must be tested ❑ ❑ by a certified tester and a copy of the results sent to Public Utilities. STRM Plans note the building will be unsprinkled. If plans change,any fire line installed must be metered with a Sensus touch-read meter in a properly sized vault and an appropriate ❑ ❑ backflow preventer installed. Backflow preventer must be tested by a certified tester and a copy of the results sent to Public Utilities. FSBR If fire sprinkler system is provided,contact Malcolm Clemons at 247-5839 for backflow ❑ ❑ requirements. At a minimum,will require a double check backflow preventer. FLM Fire lines must be metered with a Sensus touch-read meter. Meters larger than 2" must ❑ ❑ be installed in a vault as noted in JEA specifications. ❑ ❑ ❑ ❑ ❑ O ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 City of Atlantic Beach APPLICATION NUMBER p 800 Seminole Road Building Department (To be assigned by the Building Department.) ,-. �' ►�� Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 i "!J,3J9' E-mail: building-dept@coab.us ' (�(�� Date routed: 12-1177 City web-site: http://vmw.coab.us APPLICATION REVIEW ALD TRACKING FORM Property Address: QQ ���V� jq�'r,Q � artm t review required Yes No B " Applicant: nning &Zoning e dminis rator Project: I�V L ublic Works 1 u lic Utilities IV o� d A� �/ ublic Safety / Fire Services Review fee $ I Dept Signature Other Agency Review or Permit Required Review or Receip of Permit Verified Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b DateD 13 TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 City of Atlantic Beach � APPLICATION NUMBER �S Building Department r `� 800 Seminole Road (To be assigned by the Building Department.) `f''%s) x Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904) 247-5845 E-mail: building-dept@coab.us Date routed: 12 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Q� ���Ir�- f q�'?�A lbr De t review required- Yes No ui Applicant: ming oning ee Adminis rator Project: /�Vf L ublic Works ublic Utilities IV JL, d A.77rr ublic Safety / �Lw6 Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: []Approved. []Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: . I wf_ — — TREE ADMIN. Second Review: Aroved as revised. pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES tJ PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 05/14/09 PUBLIC WORKS PLAN REVIEW COMMENTS Initials: PN ML Date: Project Name/Address: Application Permit#: Check Box Check Application Tracking Comments to Add Box to Comment "Print" IMPS Provide table of impervious surface calculations for entire lot (existing and post ❑ ❑ constructidn). ESCP Provide erosion and sediment control plans with installation details and maintenance schedule. ❑ ❑ DPLN Provide drainage plans showing site topography(flow arrows, etc.) ❑ ❑ CSMP Provide construction site management plan, including Right-of-Way Permit if using right-of-way for construction parking. 11 11 TSUR Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1'contours. ❑ ❑ LDCS Section 24-66(b)of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume ❑ ❑ calculations and on-site retention required per Section 24-66(b). (See attached information sheet.) PCTS If on-site storage is required, a post construction topographic survey documenting proper ❑ ❑ construction will be required. RWPM A Right-of-Way Permit must be obtained for use ❑ ❑ REPM A Revocable Encroachment Permit must be obtained. ❑ ❑ PLWP Pool—Wellpoint(if used) must discharge into vegetated area 10' minimum from street or drainage feature (swale, structure or lagoon). ❑ ❑ DAPR All concrete driveway aprons must be 5"thick,4000 psi, with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of- ❑ ❑ way. (Commercial driveways—6"thick). URCT Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the ❑ ❑ plans. RWRS Full right-of-way restoration, including sod, is required. ❑ ❑ ROFF Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved: Advanced Disposal, Realco, Shappelle's and Waste ❑ ❑ Management) ECIN Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247-5834)for Erosion and Sediment Control ❑ ❑ Inspection prior to start of construction. MEET Recommend Owner/Contractor meet with Public Works Director to discuss proposed ❑ ❑ construction. Call 247-5834 to make an appointment. 7G y #4Ue_ 7. 9. S w `` ❑ ❑ ❑ 0 Carper, Rick From: Carper, Rick Sent: Friday, December 20, 2013 3:33 PM To: 'Pete Rodrigues'; kelly@kellyelmore.com; Kellmore; 'Glynn Taylor' Cc: 'Rick Wood'; 'Alex Acree'; Griffin, Michael; Hubsch, Jeremy; Walker, Jennifer; Graham Shirley Subject: Selva Marina Drive Entrance Modifications (Permit applications 13-00002 and 13-100098) Attachments: City Review Comments ABCC clubhouse_carper.doc Pete, addressed to you since your name is on the permit applications. Glynn & Kelly, to you since your names are on the Civil and Landscape plans respectively. Major issue (that should have been caught on my initial review of plans) is removal of 30" and 40" Live Oaks that will be required for proposed new crossover locations in Selva Marina Drive median. By size these trees meet definition for Heritage trees in Chapter 23, and mitigation will be 3"for each 1" removed. Rick Ricky L. Carper, P.E. Public Works Director/City Engineer City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 rcarperacoab.us PH: (904) 247-5834 Fax: (904) 247-5843 Florida Public Works-First to Respond, Lost to Leave www.apwaflorida.com DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W)/ Dec 13, 2013 (ES) Date of Issuance: Designer: Taylor&White& Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION 1 Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks (--40"and -30")and one 12" palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal (3"to 1"for removal of heritage trees from ROW, i.e., LO => 30"). 2 Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. 3 Landscape plans do not include proposed restoration of ground under removed crossovers (sod, trees, etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. 4 Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. 0:\Public Works\Plan Review\ABCC\City Review Comments_ABCC clubhouse_mrper.doc Pagel Taylor Fr White, Inc. Civil Design 6 Consulting Engineers January 15, 2014 D City of Atlantic Beach '14/y 2 v Public Works Department 800 Seminole Rd. Atlantic Beach,FL 32233 . Attn: Rick Carper,P.E. Re: Atlantic Beach Country Club—Clubhouse and Landscape Dear Mr. Rick Carper: The following are our responses to your Public Works plan review comments(dated 12-20-13). 1. Comment: Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks(-40"and—30")and one 12"palm tree. Tree removal permit for removal from City ROW required,along with mitigation for removal(3"to 1"for removal of heritage trees from ROW, i.e.,LO=>30"). Response: Please see plans and response from Kelly Elmore. 2. Comment: Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. Response: The pavement section on sheet No.28 has been specified for use within the clubhouse and Selva Marina Dr. median. Please see revised sheet. 3. Comment: Landscape plans do not include proposed restoration of ground under removed crossovers(sod,trees,etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed).Probably no limerock present,but if found when pavement removed, it will also require removal before planting. Response: Please see plans and response from Kelly Elmore. 4. Comment: Irrigation plans not included in submittal to PW.Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. Response: Please see plans and response from Kelly Elmore. The changes made to the building drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, Taylor& White, Inc. aA Alex Acree, P.E. Project Manager Taylor 6 White, Inc. i . Civil Design f, Consulting Enginem January 15,2014 City of Atlantic Beach Public Works Department 800 Seminole Rd. Atlantic Beach, FL 32233 Attn: Rick Carper, P.E. Re: Atlantic Beach Country Club—Clubhouse and Landscape Dear Mr. Rick Carper: The following are our responses to your Public Works plan review comments(dated 12-20-13). 1. Comment: Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks(-40"and—30")and one 12"palm tree. Tree removal permit for removal from City ROW required,along with mitigation for removal (3"to 1"for removal of heritage trees from ROW, i.e., LO=>30"). Response: Please see plans and response from Kelly Elmore. 2. Comment: Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. Response: The pavement section on sheet No. 28 has been specified for use within the clubhouse and Selva Marina Dr. median. Please see revised sheet. 3. Comment: Landscape plans do not include proposed restoration of ground under removed crossovers(sod,trees,etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. Response: Please see plans and response from Kelly Elmore. 4. Comment: Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. Response: Please see plans and response from Kelly Elmore. The changes made to the building drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, Taylor& White, Inc. AAq Alex Acree, P.E. Project Manager CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ?� =" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00100098 Date 2/27/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description DEV REV LANDSCAPE PLAN Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc landscape ab/selva cc ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SELVA MARINA COUNTRY CLUB RPC GENERAL CONTRACTORS 1600 SELVA MARINA DR 248 LEVY RD ATLANTIC BEACH FL 322335616 ATLANTIC BEACH FL 32233 (904) 241-4416 -------------------------------------------------- -------------------------- Permit . . . . . . DEV REV LANDSCAPE PLAN Additional desc . . Permit Fee . . . . . 00 Plan Check Fee . 00 Issue Date . . . . 2/27/14 Valuation . . . . 0 Expiration Date . . 2/27/14 ---------------------------------------------------------------------------- Special Notes and Comments FEES INCLUSIVE IN 13 3848 MAINTENANCE OF ENTRANCE WAY LANDSCAPING WILL REQUIRE ADOPTION AGREEMENT BETWEEN DEVELOPER/ABCC AND CITY PER RICK CARPER, PUBLIC WORKS DIRECTOR. ------------------------------------------------- --------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total . 00 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total . 00 . 00 . 00 . 00 SCAKNED PERMIT IS APPROVED ONLV IN ACCORDANCE WITH ALL CITV OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. City of Atlantic Beach �s a� Building Department APPLICATION NUMBER (To be assi ned by the Building De artment.) r I,' 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: �� 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Q 4�IVA A el;7 A De artment review re uired Yes No Buil Applicant: Plannina &Zonin T inistrator Project: C Public Works ry Public Utilities V'c ( �� Public Safety Fire Services Review fee $ o "Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: QApproved. Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. SecondReview: A roved as revised. pp ❑Denied. PUBLIC WORKS Comments: 4, PUBLIC UTILITIES � 1 PUBLIC SAFETY Reviewed by: Date: 3/ FIRE SERVICES Third Review: QApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assi9gned by the Building Department.) � 800 Seminole Road � Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 0;19' E-mail: building-dept@coab.us Date routed: �2J City web-site: http://vmw.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �lpddv�/VA K1h Q AFireServices ent review required Yes No ` Applicant: Zonin nistrator Project: Q� C rks ties /15 � L (��, ety es Review fee $ Dept Signature Other Agency Review orPermit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS zD Reviewing Department First Review: DApproved. 24ied. / (Circle one.) Comments: OaAs �P�I,, y 901K, r(Ou�{�y° ,�tOlP�t$-e odd BUILDING Ot ''"LS�G � f.G 46 S k J4- ( �• a �' s how5 fes-!«.14.5cY�nn PLANNING &ZONING �0UY6 4.r�e �tl o�.u� whar Reviewed by: ate: TREE ADMIN. Second Review: A roved as revised. pp ❑Denied. PUBLIC WORKS Comments: ,,k _TC -c _ / PUBLIC UTILITIES � G�rG � ✓� ac4c{ed uH PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. Denied. Comments: Reviewed by: Date: Revised 05/14/09 s- r,, City of Atlantic Beach APPLICATION NUMBER Building Department sa (To be assi ned b;e;;;n�y rtment.) 800 Seminole Road /g p �� Atlantic Beach, Florida 32233-5445 / Phone(904)247-5826 • Fax(904)247-5845 oil , E-mail: building-dept@coab.us Date routed: �z / .7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 11,0ddn� r0h A De artment review required Yes No Bui Applicant: 14 Planning &Zonin T inistrator Project: Q� C Public Works /) ly Public Utilities ly—el.s'1� L V c (�, C.... Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS..( Reviewing Department First Review: QApproved. Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: 0 Date: TREE ADMIN. Second Review: []Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: QApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 BP25OU01 CITY OF ATLANTIC BEACH 2/27/14 Application Tracking Step Selection by Revision 09:27:02 Application number . . . . : 13 00100098 Address . . . . . . . . . . 1600 SELVA MARINA DR RE number . . . . . . . . . 169399-0000- - Application type . . . . . DEV REV LANDSCAPE PLAN NCR OLD ACCOUNT NUMBERS . . AB04050 Tenant name, number . . . . Type options, press Enter . 2=Change 4--Delete 5=View 6=Fast log 8=Action log maintenance 9=In/out maint Path ---- Key Dates --- - Review Summary - Opt Agency description Rev Step Req In Est Cmpl Resulted Stat By _ PLANNING & ZONING A 01 Y 02/04/14 12/24/13 02/04/14 AP SLG PUBLIC WORKS 1 00 Y 01/31/14 02/04/14 01/31/14 APN RC Bottom F3=Exit F5=Land inquiry F6=Add F7=Revisions F8=Misc info inquiry F9=Corrections report F10=View 2 F11=Sort by agency F24--More keys ?t rLyr�v� If S CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00000002 Date 2/27/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description CIVIL AND SITE PLAN REVIEW Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc AB/selva country club ---------------------------------------------------------------------------- Owner Contractor ------------------------ ----------- ------------- SELVA MARINA COUNTRY CLUB RPC GENERAL CONTRACTORS 1600 SELVA MARINA DR 248 LEVY RD ATLANTIC BEACH FL 322335616 ATLANTIC BEACH FL 32233 (904) 241-4416 ---------------------------------------------------------------------------- Permit . . . . . . CIVIL AND SITE PLAN REVIEW Additional desc . . Permit Fee . . . . . 00 Plan Check Fee . 00 Issue Date . . . . 2/27/14 Valuation . . . . 0 Expiration Date . . 8/26/14 ---------------------------------------------------------------------------- Special Notes and Comments FEES INCLUSIVE IN 13 3848 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total . 00 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total . 00 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 D dDl1 G. Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: 12- 17 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM �- Property Address: •,,a �^' De t review required Yes No �QQ Applicant: oning ee Adminis rator Project: /�V 1, L, ublic Works ublic Utilities IVX-, 06 k-7 r ublic Safety / Fire Services �L w6 Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing DepartmentFFirst Review: QApproved. ]Denied. (Circle one.) mments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: QApproved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: QApproved as revised. ❑Denied. Comments: SCANNED Reviewed by: Date: Revised 05/14/09 'i CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000104 Date 2/27/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description RIGHT-OF-WAY PERMIT Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc median irrigation landscape signage ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SELVA MARINA COUNTRY CLUB OWNER 1600 SELVA MARINA DR ATLANTIC BEACH FL 322335616 ---------------------------------------------------------------------------- Permit . . . . . . RIGHT OF WAY PERMIT Additional desc . . Permit Fee . . . . . 00 Plan Check Fee . 00 Issue Date . . . . 2/27/14 Valuation . . . . 0 Expiration Date . . 8/26/14 --------------------------------------------------------- ------------------- Special Notes and Comments REVIEW FEES INCLUSIVE IN PERMIT 13 3848 Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Sheet ML2 - Reclaimed water meter needs to be installed for irrigation - 2" meter to be installed prior to backflow preventer. No backflow preventer needed on reuse irrigation service . Maintenance of entrance way landscaping option, (if constructed) , will require adoption agreement between Developer, ABCC and City. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total . 00 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total . 00 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. t�L�rir City of Atlantic Beach APPLICATION NUMBER Building Department be assigned by the Building Dep rtment.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 / 7 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 6Q JJ'IVA,�,jrin 0- Department review required Yes No Buil Applicant: Planning &Z ' Tree Administrator Project: �� ulic or ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review^ Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmc -il Protection Florida Dept.of Transport,': n St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Reviev, roved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: D TREE ADMIN. Second Review: ❑Approved as revised. ❑Denie PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 SyLy;y� City of Atlantic Beach LV5845 - 4APPLICATION NUMBER /-T 'D JS r S` Building Department �' be assigned by'th/e Building Dep rtment.) f 800 Seminole Road JA 7 2014 7 �Q Atlantic Beach, Florida 32233-544 Phone(904)247-5826 • Fax(904E-mail: building-dept@coab.us Date routed: v� 7 // City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �f� 6Q J61V#, 14I74r/n tt j Department review required Yes No Buil Applicant: \J Plannin Z Tree Administrator Project: u lis Vla ublic Utilities Public Safety / Fire Services Review fee $ Dept Signature 9 w Other Agency Review Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmc '-iI Protection Florida Dept.of Transport.^: n St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: AP PLICATION STATUS Reviewing Department First Review. ❑Denies. (Circle one.) Comments: P- of­:iF-bTn,!o<iE BUILDING of'170A), �S�1,V`C'l'��� Gt11 C �'L�(,zv. 1✓�r '�`�C;P77 axJ /�n£E r►1r � � � r� cc � Grp/ PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Deniev Comments: Reviewed by: Date: Revised 05/14/09 sLvr�+e_ City of Atlantic Be iAPPLICATION NUMBER F REC s� Building DepartmE FT`T �D (To be assigned by the Building Dep rtment.) 800 Seminole Road Atlantic Beach, Florida 3" a3-5445 JAN 27 2014 Phone(904)247-5826 • 3x(904)2#7-5845 / 7 E-mail: building-dept@c_ o.us BY: L2ate routed: City web-site: http://www .oab.us APPLICATIOr�, REVIEW AND TRACKING FORM Property Address: 6Q 5���� ///A/'l%) tt Department review required Yes No L Bui Applicant: �,[\J C Planning &Z Tree Administrator Project: u lic or ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review ti Permit Required Review or Rece pt Date of Permit Verifie B Florida Dept. of Environmc ,,I Protection Florida Dept. of Transport.'. n St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Reviev NApproved. Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: ► �� I TREE ADMIN. Second Revi, v: ❑Approved as revised. ❑Denied. Comments: Mp Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS 800 Seminole Road 904-247-5800 MENNEN Atlantic Beach,Florida 32233-5445 Fax 904-247-5845 PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION. Date 11A I 1 PERMIT# Job Address 1600 Selva Marina Drive Fl SSUED BY THE CITY Permitee: RPC General Contractors, Inc. Telephone# 904-241-4416 Permittee Address: 248 Levy Road, Atlantic Beach, FL 32233 Requesting Permission to Construct: Median Landscape and Irrigation; Signage Location: (Reference to Cross-Street) Selva Marina Drive Median - South End 1. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Yes ( ) No (X) Date: Bell South Telephone Company Yes ( ) No (X) Date: Ferrell Gas Yes ( ) No (Xl Date: Comcast Yes ( ) No Date: 2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Peter J. Rodrigues (Contractor's Pro'ect Superintendent) located at 1600 Selva Marina Drive Telephone#: 904-545-59�1 4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with days. If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again immediately upon completion. OWNER: Peter J. Rodrigues -resident RPC General Contractors, Inc . on Signed: Date: i � behalf of Atlantic Beach Partners - I Before me this !t^ ay of aa," in tthe County of Duval, � V_ State q or as personally appeared . 0C Y q:L)e_S Notary u c Large,St to of Florida,County of Duval. My com ion expires. M3MC( 2-S Z-C>�-}- ersonally Known: Produced Identification: "Y DMHEU.E SIEBKE MY COMMISSION#FF 000465 • is EXPIRES:March 25,2017 Bonded Thru Notary Pudic Underwriters Kaluzniak, Donna From: Kaluzniak, Donna Sent: Wednesday, January 29, 2014 9:27 AM To: Pete Rodrigues Subject: Landscape Median Permit 14-0104 Attachments: 1600 Selva Marina Dr.pdf Pete—FYI - here is a GIS map showing the utilities in the area. I noticed the reuse irrigation line has a backflow preventer&valve. It needs a 2"meter. But a backflow preventer is not needed on the reuse line. I'll put the comments on your permit—thanks, Donna Donna Kaluzniak, Utility Director City of Atlantic Beach 902 Assisi Lane Atlantic Beach,FL 32233 (904)270-2535 dkaluzniak@coab.us i 1670 1644 1641 M N" 1665 e a M M 1635 1638 1660 ` 1655 24" Storm e M 15" Storm • M 1632 8" Sewer Main � y = A i 1645 1626 1600 " 6"AC Water Main 1620 " , i 8" Cl Force Main 1633 , , , 1600 " Sewer Services N 1614 Water Services 1619 M ' , , , 10" Sewer Main --------------- NA E 1601 1600 M , 1 " CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF W, AND EASEMENTS i. b 11 J .. 800 Seminole Road 904-247-5800 Atlantic Beach,Florida 32233-5445 Fax 904-247-5845 PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION. Date PERMIT# Job Address 1600 Selva Marina Drive ISSUED BY THE CITY Permitee: RPC General Contractors, Inc. Telephone# 904-241-4416 Permittee Address: 248 Levy Road, Atlantic Beach, FL 32233 -- Requesting Permission to Construct: Median Landscape and Irrigation; Sif;;:age Location: (Reference to Cross-Street) Selva Marina Drive Median - South rid 1. Applicant declares that prior to filing this application he has ascertatr:�d the location of all existing utilities, both aerial and underground and the accurate locations are shown on sketches. A Letter of Notification was mailed to the following Utilities/Municipaliti Jacksonville Electric Authority Yes( ) (X) Date: Bell South Telephone Company Yes( (X) Date: Ferrell Gas Yes( ; (A Date: Comcast Yes( ) I;o (X Date.- 2. ate:2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach or Florida Department :` Transportation Standards and be performed under the supervision of Peter J. Rodrigues (Contractor's ProIect Superintendent) located at 1600 Selva Marina Drive _Telephone#: 904-545-5911 4. All materials and equipment shall be subject to inspection by the Direc. of Public Works or his designee. 5. All city property shall be restored to its original condition as far as pra::cal, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a a� of a recent survey shall be made a part of this permit. Calculations showing any increase in impervi area on owner's lot or in the city Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with days. If the beginning date is more than 60 days from date of permit approval, then permittee mu_ -.view the permit with the Director of Public Works to make sure no changes have occurred in the area that uld affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein se-, are granted only to the extent of the City's right, title and interest in the land to be entered upon and useu :he holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again immediately upon completion. OWNER: Peter J. Rodrigues, President RPC General Contractors, Inc . on behalf )f Atlantic Beach Partners Signed:4' ion Date: I �I Before s E��)p ayof a+w intheCountyof Duval,State C; as personally apared I�U�1Yl�PSS Notary Large,St to of Florida,County of Duval. My corn expires: 4AW- d l Vs 6;1. rally Known: Produced Identificatior "Yid.; DAMELLE SIEBIE MY COMMISSION t FF 000465 �A EXPIRES:March 25,2017 Bonded Th.Notary Pudic Ucdenv 1M PUBLIC WORKS PLAN REVIEW COMMENTS Initials: PN ML Date: Project Name/Address: s�614�-gVK4t, j Application Permit#: Check Box Check Application Tracking Comments to Add Commen "Print" IMPS Provide table of impervious surface calculations for entire lot (existing and post ❑ constructidn). ESCP Provide erosion and sediment control plans with installation details and maintenance schedule. ❑ ❑ DPLN Provide drainage plans showing site topography(flow arrows, etc.) ❑ ❑ CSMP Provide construction site management plan, including Right-of-Way Permit if using right-of-way for construction parking. ❑ 13 TSUR Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1'contours. ❑ 13 LDCS Section 24-66(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume ❑ 11calculations and on-site retention required per Section 24-66(b). (See attached information sheet.) PCTS If on-site storage is required, a post construction topographic survey documenting proper ❑ ❑ construction will be required. RWPM A Right-of-Way Permit must be obtained for use ❑ ❑ REPM A Revocable Encroachment Permit must be obtained. ❑ ❑ PLWP Pool—Wellpoint (if used) must discharge into vegetated area 10' minimum from street or drainage feature (swale, structure or lagoon). ❑ ❑ DAPR All concrete driveway aprons must be 5"thick, 4000 psi, with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of- ❑ ❑ way. (Commercial driveways—6" thick). URCT Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the ❑ ❑ plans. RWRS Full right-of-way restoration, including sod, is required. ❑ ❑ ROFF Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved: Advanced Disposal, Realco, Shappelle's and Waste ❑ ❑ Management) —FC—IN -Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247-5834)for Erosion and Sediment Control ❑ ❑ Inspection prior to start of construction. MEET Recommend Owner/Contractor meet with Public Works Director to discuss proposed ❑ ❑ construction. Call 247-58)4 to make an app intm nt. 1Gn�. 2h 0 Carper, Rick From: Carper, Rick Sent: Friday, December 20, 2013 3:33 PM To: 'Pete Rodrigues'; kelly@kellyelmore.com; Kellmore; 'Glynn Taylor' Cc: 'Rick Wood'; 'Alex Acree'; Griffin, Michael; Hubsch, Jeremy; Walker, Jennifer; Graham Shirley Subject: Selva Marina Drive Entrance Modifications (Permit applications 13-00002 and 13-100098) Attachments: City Review Comments ABCC clubhouse_carper.doc Pete, addressed to you since your name is on the permit applications. Glynn & Kelly, to you since your names are on the Civil and Landscape plans respectively. Major issue (that should have been caught on my initial review of plans) is removal of 30" and 40" Live Oaks that will be required for proposed new crossover locations in Selva Marina Drive median. By size these trees meet definition for Heritage trees in Chapter 23, and mitigation will be 3"for each 1" removed. Rick Ricky L. Carper, P.E. Public Works Director/City Engineer City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 rcarper(c)coab.us PH: (904) 247-5834 Fax: (904)247-5843 Florida Public Works-First to Respond, Lost to Leave www.apwaflorida.com i DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W)/ Dec 13, 2013 (ES) Date of Issuance: Designer: Taylor&White & Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION 1 Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks (-40" and -30")and one 12" palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal (3"to 1"for removal of heritage trees from ROW, i.e., LO => 30"). 2 Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. 3 Landscape plans do not include proposed restoration of ground under removed crossovers (sod, trees, etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. 4 Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country �� Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. �t 0:\Public Works\Plan Review\ABCC\City Review Comments_ABCC clubhouse_mrper.doc Page 1 1111 (a January 29, 2014 euthenics City of Atlantic Beach ', C� Public Works Department u AIV p 800 Seminole Rd. B Atlantic Beach,FL 32233 y �' Attn: Rick Carper,P.E. Re: Atlantic Beach Country Club—Clubhouse and Landscape Dear Mr. Rick Carper: The following are our responses to your Public Works plan review comments(dated 12-20-13). 1. Comment: Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks(-40"and—30")and one 12"palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal(3"to 1" for removal of heritage trees from ROW, i.e., LO=>30"). Response: The 40" Live Oak will be saved and the crossover relocated 5' south of the face of the tree. The 30" Live Oak is actually 23.24" in caliper and will be removed and mitigated at 1:1. Seven (7) 5" Live Oaks will be planted in the median as indicated on the drawing ML-1. The palm is included in the 35" of provided new plant material. 2. Comment: Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. Response: This comment will be handled by Taylor& White. 3. Comment: Landscape plans do not include proposed restoration of ground under removed crossovers(sod,trees,etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present,but if found when pavement removed, it will also require removal before planting. Response: The existing asphalt crossovers and any lime rock will be removed and the requisite amount of topsoil will be added to match existing median grades. The areas will be sodded and irrigated. 4. Comment: Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. Response: Irrigation plans for the median and R.O.W. are supplied on Sheet ML-2 and Clubhouse Design Sheets IR-1-4. The irrigation system will utilize reclaimed water from the 8" reclaimed supply line that runs down the new Atlantic Beach LANDSCAPE ARCHITECTURE • SITE PLANNING • URBAN DESIGN 1650 Beach Avenue Atlantic Beach,Florida 32233 direct 904.246.6219 cell 904.333.7483 fax 904.241.8382 kellmore@comcast.net Drive and terminates in the Selva Marina Drive median. The Developer/ABCC will be responsible for establishment of sod and trees. The plans in question are initial submittals and have a submittal date in the right-hand column. The landscape drawings are in response to comments. Please feel free to contact me if there are any further questions or comments. I�pspectfall , Kelly R. lmore,RLA,ASLA Euthenics Studio Carper, Rick From: Carper, Rick Sent: Friday, December 20, 2013 3:33 PM To: 'Pete Rodrigues'; kelly@kellyelmore.com; Kellmore; 'Glynn Taylor' Cc: 'Rick Wood'; 'Alex Acree'; Griffin, Michael; Hubsch, Jeremy; Walker, Jennifer; Graham Shirley Subject: Selva Marina Drive Entrance Modifications (Permit applications 13-00002 and 13-100098) Attachments: City Review Comments ABCC clubhouse_carper.doc Pete, addressed to you since your name is on the permit applications. Glynn & Kelly, to you since your names are on the Civil and Landscape plans respectively. Major issue (that should have been caught on my initial review of plans) is removal of 30" and 40" Live Oaks that will be required for proposed new crossover locations in Selva Marina Drive median. By size these trees meet definition for Heritage trees in Chapter 23, and mitigation will be 3"for each 1" removed. Rick Ricky L. Carper, P.E. Public Works Director/City Engineer City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 rcarperacoab.us PH: (904)247-5834 Fax: (904)247-5843 Florida Public Works-First to Respond, Lost to Leave www.apwaflorida.com DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W) / Dec 13, 2013 (ES) Date of Issuance: Designer: Taylor&White & Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION 1 Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks (-40" and -30")and one 12" palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal (3" to 1"for removal of heritage trees from ROW, i.e., LO => 30"). 2 Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. 3 Landscape plans do not include proposed restoration of ground under removed crossovers (sod, trees, etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. 4 Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. 0:\Public Works\Plan Review\ABCC\City Review Comments_ABCC clubhouse_carper.doc Page 1 rvijiLn- rLmiv MtVJtW LLIMMILIVi3 /,2 �// 3 Initials: PN ML Date: Project Name/Address: D s (J�. Q� 1 .� � � �`/Application Permit#: Check Box Check Application Tracking Comments to Add Box to Comment "Print" IMPS Provide table of impervious surface calculations for entire lot (existing and post ❑ ❑ constructidn). ESCP Provide erosion and sediment control plans with installation details and maintenance schedule. ❑ ❑ DPLN Provide drainage plans showing site topography(flow arrows, etc.) ❑ ❑ CSMP Provide construction site management plan, including Right-of-Way Permit if using right-of-way for construction parking. 13 TSUR Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1'contours. ❑ ❑ LDCS Section 24-66(b)of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-66(b). (See attached information ❑ ❑ sheet.) PCTS If on-site storage is required, a post construction topographic survey documenting proper ❑ ❑ construction will be required. RWPM A Right-of-Way Permit must be obtained for use ❑ ❑ REPM A Revocable Encroachment Permit must be obtained. 13 0 PLWP Pool—Wellpoint(if used) must discharge into vegetated area 10' minimum from street or drainage feature(swale, structure or lagoon). ❑ ❑ DAPR All concrete driveway aprons must be S"thick, 4000 psi, with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of- ❑ ❑ way. (Commercial driveways—6"thick). URCT Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the ❑ ❑ plans. RWRS Full right-of-way restoration, including sod, is required. ROFF Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved: Advanced Disposal, Realco, Shappelle's and Waste ❑ ❑ Management) ECIN Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works(247-5834) for Erosion and Sediment Control ❑ ❑ Inspection prior to start of construction. MEET Recommend Owner/Contractor meet with Public Works Director to discuss proposed construction. Call 247-5834 to make an app intm nt. ' ❑ ❑ s l/v�"�"� G b° Q, 1Gn�. (Zh ❑ O ❑ Carper, Rick From: Carper, Rick Sent: Friday, December 20, 2013 3:33 PM To: 'Pete Rodrigues'; kelly@kellyelmore.com; Kellmore; 'Glynn Taylor' Cc: 'Rick Wood'; 'Alex Acree'; Griffin, Michael; Hubsch, Jeremy; Walker, Jennifer; Graham Shirley Subject: Selva Marina Drive Entrance Modifications (Permit applications 13-00002 and 13-100098) Attachments: City Review Comments_ABCC clubhouse_carper.doc Pete, addressed to you since your name is on the permit applications. Glynn & Kelly, to you since your names are on the Civil and Landscape plans respectively. Major issue (that should have been caught on my initial review of plans) is removal of 30" and 40" Live Oaks that will be required for proposed new crossover locations in Selva Marina Drive median. By size these trees meet definition for Heritage trees in Chapter 23, and mitigation will be 3"for each 1" removed. Rick Ricky L. Carper, P.E. Public Works Director/City Engineer City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 rcarper@coab.us PH: (904)247-5834 Fax: (904) 247-5843 Florida Public Works-First to Respond, Lost to Leave www.apwafforida.com DESIGN REVIEW COMMENTS CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS Atlantic Beach, Florida Project Segment: Atlantic Beach Country Club Clubhouse and Landscape Date Returned: 12/20/2013 Design Phase: Plans dated June 2013 (T&W)/ Dec 13, 2013 (ES) Date of Issuance: Designer: Taylor&White & Euthenics Studios Reviewer: Rick Carper, P.E. Sheet RESPONSE TO COMMENT BY CITY NO. ITEM COMMENT DESIGN CONSULTANT ACTION ON PLANS ACTION/RESOLUTION 1 Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks (-40" and -30") and one 12" palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal (3" to 1"for removal of heritage trees from ROW, i.e., LO => 30"). 2 Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. 3 Landscape plans do not include proposed restoration of ground under removed crossovers (sod, trees, etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. 4 Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. 0:\Public Works\Plan Review\ABCC\City Review Comments_ABCC clubhouse_carper.doc Page 1 FUtSUL WUKK5 PLAIN REVIEW COMMENTS l I V ,)nl Initials: PN flIVIL "Date: Project Name/Address: ` 1 `�� �� �/1 Cy Application Permit#: Check Box Check Application Tracking Comments to Add Box to Comment" "Print" IMPS Provide table of impervious surface calculations for entire lot (existing and post construction). ❑ ❑ ESCP Provide erosion and sediment control plans with installation details and maintenance schedule. ❑ 13DPLN Provide drainage plans showing site topography(flow arrows, etc.) ❑ ❑ CSMP Provide construction site management plan, including Right-of-Way Permit if using right-of-way for construction parking. ❑ ❑ TSUR Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1'contours. ❑ ❑ LDCS I Section 24-66(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-66(b). (See attached information ❑ ❑ sheet.) PCTS If on-site storage is required, a post construction topographic survey documenting proper construction will be required. ❑ 0 RWPM A Right-of-Way Permit must be obtained for use ❑ O REPM A Revocable Encroachment Permit must be obtained. PLWP Pool—Wellpoint(if used) must discharge into vegetated area 10' minimum from street or drainage feature(swale, structure or lagoon). ❑ ❑ DAPR All concrete driveway aprons must be 5"thick,4000 psi, with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of- ❑ ❑ way. (Commercial driveways—6"thick). URCT Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the ❑ ❑ plans. RWRS Full right-of-way restoration, including sod, is required. 11 11 ROFF Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved: Advanced Disposal, Realco, Shappelle's and Waste ❑ ❑ Management) ECIN Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works(247-5834)for Erosion and Sediment Control ❑ ❑ inspection prior to start of construction. MEET Recommend Owner/Contractor meet with Public Works Director to discuss proposed construction. Call 247-5834 to make an appointment. ❑ 7te e(le- -. a. Aj C, de ❑ ❑ ® ❑ / J` I�r � - _ iIlli I /kl� �� — (� euthenics ` ti January 29, 2014 \ City of Atlantic Beach 800 Seminole Rd. 29 a Atlantic Beach, FL 32233 l Attn: Jeremy Hubsch Re: Atlantic Beach Country Club—Landscape Dear Mr. Jeremy Hubsch: The following is our response to your Planning&Zoning plan review comments (dated 12-20- 13). 1. Comment: Plans generally look good. However,please add a phase line to sheet 10.2 that shows future landscaping will occur when courts are built. Response: A `Future Landscape' bubble around the exterior perimeter of future Tennis Courts 8,9 & 10 has been added to Sheet 10.2 of the ABCC Clubhouse Plans. The changes made to the landscape drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, rV Kelly E ore Euthenics Studio LANDSCAPE ARCHITECTURE • SITE PLANNING • URBAN DESIGN 1650 Beach Avenue Atlantic Beach,Florida 32233 direct 904.246.6219 cell 904.333.7483 fax 904.241.8382 kellmore@comcast.net � RPC� General Contractors, Inc. 248 Levy Rd. P.O. Box 330775 Atlantic Beach, FL 32233 (904)241-4416-(904) 241-4427fax TO: City of Atlantic Beach ATTN: Shirley ADDRESS: 800 Seminole Rd. DATE: 1/29114 CITY/STATE/ZIP: Atlantic Beach, FL 32233 REFERENCE/JOB: ABCC 013119 WE ARE SENDING YOU: --=ATTACHED X UNDER SEPARATE COVER VIA Hand Delivery SHOP DRAWINGS PRINTS X PLANS Fl SAMPLES �— SPECIFICATIONS COPY OF LETTER X FOR APPROVAL COPIES DATE NO. DESCRIPTION 3 1/15/14 1 Rich Carper, Public Works: Clubhouse & Landscape Comment Response Letter from Taylor&White, Inc. 3 1/13/14 2 Signed & Sealed Clubhouse Paving and Drainage Plan 3 1/29/14 3 Rich Carper, Public Works: Clubhouse & Landscape Comment Response Letter from Euthenics 3 4 Signed &Sealed Sets of Revised Median & Irrigation Plans Sheets ML1, MI-2, MI-3, MI-4; IR1, IR2, IR3, IR4 3 1/29/14 5 Jeremy Hubsch, Planning &Zoning: Landscape Comment Response Letter from Euthenics 3 6 Signed &Sealed Plan L10.2 Dear Shirley: Please find the documents containing our responses to the comments received from Planning &Zoning and Public Works dated 12/20/13. Please contact me with any questions or concerns. Sincerely, Catherine Lewin RPC Design CIO J� r January 29, 2014 euthenics City of Atlantic Beach Public Works Department ✓qN 0� 800 Seminole Rd. By 19 2 Atlantic Beach, FL 32233 Attn: Rick Carper, P.E. Z.� Re: Atlantic Beach Country Club—Clubhouse and Landscape Dear Mr. Rick Carper: The following are our responses to your Public Works plan review comments(dated 12-20-13). 1. Comment: Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks(--40"and—30")and one 12"palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal (3"to 1" for removal of heritage trees from ROW, i.e., LO=> 30"). Response: The 40" Live Oak will be saved and the crossover relocated 5' south of the face of the tree. The 30" Live Oak is actually 23.24" in caliper and will be removed and mitigated at 1:1. Seven (7)5" Live Oaks will be planted in the median as indicated on the drawing ML-1. The palm is included in the 35" of provided new plant material. 2. Comment: Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. Response: This comment will be handled by Taylor& White. 3. Comment: Landscape plans do not include proposed restoration of ground under removed crossovers(sod,trees,etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present,but if found when pavement removed, it will also require removal before planting. Response: The existing asphalt crossovers and any lime rock will be removed and the requisite amount of topsoil will be added to match existing median grades. The areas will be sodded and irrigated. 4. Comment: Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. Response: Irrigation plans for the median and R.O.W. are supplied on Sheet ML-2 and Clubhouse Design Sheets IR-1-4. The irrigation system will utilize reclaimed water from the 8" reclaimed supply line that runs down the new Atlantic Beach LANDSCAPE ARCHITECTURE • SITE PLANNING • URBAN DESIGN 1650 Beach Avenue Atlantic Beach,Florida 32233 direct 904.246.6219 cell 904.333.7483 fax 904.241.8382 kellmore@comcast.net Drive and terminates in the Selva Marina Drive median. The Developer/ABCC will be responsible for establishment of sod and trees. The plans in question are initial submittals and have a submittal date in the right-hand column. The landscape drawings are in response to comments. Please feel free to contact me if there are any further questions or comments. Re pectfully, KellNatoe�� R. lmore, RLA,ASLA Euthenics Studio INI IIIS-N- 1 lim January 29, 2014 euthenics JAN 2 9 2014 City of Atlantic Beach 800 Seminole Rd. BY Atlantic Beach, FL 32233 Attn: Jeremy Hubsch a f �Re: Atlantic Beach Country Club—Landscape Dear Mr. Jeremy Hubsch: The following is our response to your Planning & Zoning plan review comments (dated 12-20- 13). 1. Comment: Plans generally look good. However, please add a phase line to sheet 10.2 that shows future landscaping will occur when courts are built. Response: A `Future Landscape' bubble around the exterior perimeter of future Tennis Courts 8, 9 & 10 has been added to Sheet 10.2 of the ABCC Clubhouse Plans. The changes made to the landscape drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, Kelly Elmore Euthenics Studio LANDSCAPE ARCHITECTURE • SITE PLANNING • URBAN DESIGN 1650 Beach Avenue Atlantic Beach,Florida 32233 direct 904.246.6219 cell 904.333.7483 fax 904.241.8382 kellmore@comcast.net III 1 �1 4 euthenics January 29, 2014 City of Atlantic Beach 800 Seminole Rd. Atlantic Beach, FL 32233 Attn: Jeremy Hubsch Re: Atlantic Beach Country Club—Landscape Dear Mr. Jeremy Hubsch: The following is our response to your Planning&Zoning plan review comments(dated 12-20- 13). 1. Comment: Plans generally look good. However,please add a phase line to sheet 10.2 that shows future landscaping will occur when courts are built. Response: A `Future Landscape' bubble around the exterior perimeter of future Tennis Courts 8, 9 & 10 has been added to Sheet 10.2 of the ABCC Clubhouse Plans. The changes made to the landscape drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, c �' Kelly El ore Euthenics Studio LANDSCAPE ARCHITECTURE • SITE PLANNING • URBAN DESIGN 1650 Beach Avenue Atlantic Beach,Florida 32233 direct 904.246.6219 cell 904.333.1483 fax 904.241.8382 kellmore@comcast.net CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS 800 Seminole Road 904-247-5800 j! Atlantic Beach,Florida 32233-5445 Fax 904-247-5845 PLEASE ISUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION. Date 1 Iy V I PERMIT F Job Address 1600 Selva Marina Drive ISSLIELSYTHE CITY Permitee: RPC General Contractors, Inc. Telephone# 904-241-4416 Permittee Address: 248 Levy Road, Atlantic Beach, FL 32233 Requesting Permission to Construct: Median Landscape and Irrigation; `,,.l.Ige Location: (Reference to Cross-Street) Selva Marina Drive Median - South End 1. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Yes( ) Ivo (X) Date: Bell South Telephone Company Yes( )' No (X) Date: Ferrell Gas Yes ( ) No (Xj Date: Comcast Yes( ) No Date.- 2. ate:2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other faci!iiies and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Peter J. Rodrigues _ (Contractor's Prosect Superintendent) located at 1600 Selva Marina Drive Telephone#: 904-545-5911 4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with days. If the beginning date is more than 60 days from date of permit approval, then permittee mus' �aview the permit with the Director of Public Works to make sure no changes have occurred in the area that )uld affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set -m are granted only to the extent of the City's right, title and interest in the land to be entered upon and used ' ;•the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmleFs the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in a: manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) t s prior to starting work and again immediately upon completion. OWNER:Peter J. Rodrigues resident RPC Ger -.cal Contractors, Inc . on behal� f Atlantic Beach Partners Signed: — Date: I L 14 Before me s ay of a+1 in the CoQunty of Duvai State C f o' , as personally app ared ll4AY1 qve�s Notary u c Large,St to of FW�da,County of Duval. My corn ion expires: ZS ZUV1 ersonally Known: Produced Identification: ;*A,""�;9 DMBEU.E SIEBKE +? MY COMMISSION i FF 000465 EXPIRES:March 25,2017 -? ;n� Bonded Thru tJofery Pubk Uadenv im Taylor Z White, Inc. Civil Design b Conwlting Enginem GG 0' p� ry 15 January � �~ 2014 g � City of Atlantic Beach I� Public Works Department 800 Seminole Rd. U is Atlantic Beach, FL 32233 JAN 2 9 2014 Attn: Rick Carper, P.E. Re: Atlantic Beach Country Club—Clubhouse and Landscape By� Dear Mr. Rick Carper: 2 21 P The following are our responses to your Public Works plan review comments(dated 12-20-13). 1. Comment: Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks(-40"and—30")and one 12"palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal (3"to 1"for removal of heritage trees from ROW, i.e., LO=> 30"). Response: Please see plans and response from Kelly Elmore. 2. Comment: Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. Response: The pavement section on sheet No. 28 has been specified for use within the clubhouse and Selva Marina Dr. median. Please see revised sheet. 3. Comment: Landscape plans do not include proposed restoration of ground under removed crossovers(sod,trees,etc.).(Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. Response: Please see plans and response from Kelly Elmore. 4. Comment: Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. Response: Please see plans and response from Kelly Elmore. The changes made to the building drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, Taylor& White, Inc. Alex Acree, .E. �} Project Manager ,�� �� �' S CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD !J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �J1I1�� Application Number . . . . . 13-00100094 Date 2/10/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description DEV REV COMM AND INDUSTRIAL Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 -------------------------------------------------- --- ------------------ Application desc It ----------------------------------------------------------- -----ENGINEERING PLANS/DRAINAGE/SEWER ROAD --------------------------------------------------4r4W -------- Owner Contractor ------------------------ ------------------------ SELVA MARINA COUNTRY CLUB BARCO-DUVAL ENGINEERING INC 1600 SELVA MARINA DR 1462 HEATHER GLEN LN ATLANTIC BEACH FL 322335616 MIDDLEBURG FL 32068 ---------------------------------------------------------------------------- Permit . . . . . . DEV REV COMMERCIAL/INDUSTRIAL Additional desc . . Permit Fee . . . . . 00 Plan Check Fee . 00 Issue Date . . . . 12/10/13 Valuation . . . . 0 Expiration Date . . 12/10/13 ---------------------------------------------------------------------------- Special Notes and Comments Avoid damage to underground water/sewer utilit�epj Verify vertical and horizontal location of utilities kHarYc�lfnp f necessary. If field coordination is needed, call` 247 _58 . Ensure all meter boxes, sewer cleanouts and valve cover's are set to grade and visible. A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible . Fire lines must be metered with a Sensus touch-read meter. Meters larger than 2" must be installed in a vault as noted in JEA specifications . Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible . A sewer cleanout must be installed at the property line . Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible . Fire lines must be metered with a Sensus touch-read meter. Meters larger than 2" must be installed in a vault as noted in JEA specifications . ---------------------------------------------------------------------------- PERMIT Qt ReMVF*OSLV IN ACCORDANCE WIT+i NLL('ITl ISA' �F�I E.� 9/Ar!vI)`111E FLORIDA 01 BUILDING CODES. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J =" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 13-00100094 Date 2/10/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENG REV COMMERCIAL BLDG . 01 ENG REV PRE APP CONSTR PN 1692 . 22 UTIL REV COMMERCIAL BLDG . 01 UTIL REV PRE APP CONSTR 400 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total . 00 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 2092 . 25 2092 . 25 . 00 . 00 Grand Total 2092 . 25 2092 . 25 . 00 . 00 PERMIT IS APPROVED ONLI' IN ACCORDANCE WITH ALL CITV OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Depart ent.) (, 800 Seminole Road /DDD �r Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 Q ? DWI E-mail: building-dept@coab.us L Date routed. / J City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I o4 J41114 /�/a1"/n A- br ent review required Yes No B . . Applicant: //g r`_ fanning &Zoning Tr inistrator Project: �'J / /Q Public Works u lic Utilitie �ro 16 7- Jzz10 Public Safety f5-Do - V144.1 /F/�J"�r1Fire S rvices Review fee $ Dept Signatur TOv'riall oz O r Agency Review or Permit Required Review or Receipt Date �� OD of Permit Verified B YYY D Florida pt. of Environmental Protection �� hh Florida Vept. of Transportation JV St. Jo s River Water Management District Army orps of Engineers avis' n of Hotels and Restaurants ` a1r Divi on of Alcoholic Beverages and Tobacco \ Oth r: APPLICATION STATUS Reviewing Department First Review: Approved. []Denied. Z 2 (Circle one.) Comments: �� Z I BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: IC UTILITI �'� 09 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 City of Atlantic Beach APPLICATION NUMBER (To be assigned by the Building Department.) .� Building Department /� y /DD 800 Seminole Road I Atlantic Beach, Florida 32233-5445 / A Phone(904)247-5826 • Fax(904)247-5845 Date routed: '��J731yr E-mail: building-dept@coab.us City web-site: http://wm.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: r�d� JJ111A r�� A- T r $T,$in;istrat0r w No P Y 7. L1 Applicant: �J9 Public Works Project: �'I ubfic Utilities � Z f� Public Safety--#L- l Fire Services {ter Review fee $ pept Signature _ ._ . f A rt a Date Other Agency Review or Permit Required of Permit Verified Review or Receipt t Florida Dept. of Environmental Protection Byd Florida Dept. of Transportation tj�('�,r6(,nb St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14109 �wfi 3 ho►'� O'llfls- W t w t l row C 1i � C)� +(:) Putew t-o Sharc. w� Taylor 6 WII are, dQ w l � Consulting and Design Engineer: �r ' — h��, d– s+ter ��tt k, Ot/,r�r 9556 Historic Kings Road S.,Suite 102-Jackson, S LAS-11`v V � Tel:(904)346-0671 - Fax:(904)346- V �1 www.taylorandwhde.com Transmiftal Please Deliver to: Date: 11/13/2013 Project No.: 12210 City of Atlantic Beach Building Department Attention: Mr. Michael Griffin 800 Seminole Road Atlantic Beach, FL 32233 Re: Atlantic Beach Country Club (904)247-5814 Building Permit These documents are transmitted via: Express 1 Complete Plans Checklist 1 Building Permit Application Remarks: Mr.Griffin, Attached is the Building Permit Application and Checklist for the Civil Plan Approval of Atlantic Beach Country Club. This permit will be for the Civil Horizontal Permit only and does not include any of the vertical structures. Per Mr. Rick Carper,the recently submitted plans to the City of Atlantic Beach are acceptable for use with this Building Permit Application. Please review and let me know if you need an additional information. Thanks, Signed: Alex R.Acree, P.E. Copies To: 21 File ❑ ❑ ❑ This transmission may contain information that is privileged or confidential. It is intended for the sole use of the individual or entity to whom it is addressed. If you have received this transmission in error,please notify us immediately by telephone and return the original message to us at the address below. If you are not the intended recipient of this message,or the employee or agent responsible for delivering the message to the intended recipient,you are hereby notified that any dissemination,distribution or copying of this transmission is strictly prohibited. '. 1 L Signature of Owner Signature of Contractor Print Name 'Q� /� J ,/y�_ ,,p ` [..' 6,....._ .... u....._?.C...G� Ih3- MP '-Print Name N . • 1 t C� r.....�. ........ .. ................. Sworn to and subscribed before me this/�Day of /Vd uG/wb tr .20J—:L Sworn to and subscribed before me//..� this a Day of rf�QiN2 /ft"20/3 Nota Pu is N ry PAC - "r'i"'•y, TAMMY oAR&LENS i Notary Pubk-!Nate of Florids + �� JAYNftNNIt�IAQd My Comm.Ettpirsa Oct 20,2016 Notary Public,State of Rodde 4,hOtt, Commission#EE 211667 =�� = My Comm.Expires Mar.25,2016 i; -,R.,�h.•' Commission No.EE 163470 � BUILDING PERMIT APPLICATION NOV 3 2013 CITY OF ATLANTIC BEACH By 800 Seminole Road,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 Job Address: 1600 SELVA MARINA DRIVE Permit Number: Legal Description See Attached Parcel# 169399-0000,169399-0010,172024-0000 Floor Area of Sq.Ft. Sq.Ft Valuation of Work$ 6M Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed?(Circle one): Yes 0 N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: The re-development of the existing Selva Marina Golf Course and Country Club with the addition of up to two hundred(200)single-family lots with associated utilities and stormwater management system. Property Owner Information: Name:Atlantic Beach Partners,LLC Address: 414 Old Hard Road.Suite 502 City Fleming Island State FL Zip 32003 Phone (904)264-6553 E-Mail or Fax#(Optional) rw2Wwooddev.net Contractor Information: Company Name: Barco-Duval Engineering,Inc. Qualifying Agent: Ron Price Address: 7587 Wilson Blvd. City Jacksonville State FL Zip 32210 Office Phone (904)772-1313 Job Site/Contact Number Fax# (904)771-7912 State Certification/Registration#�lo 7 l�r�t b�l r/ 9ZA W 7137 Architect Name&Phone# Cronk Duch Architecture—Cliff Duch,ICAA,A.I.A.(904)302-9848 Engineer's Name&Phone# Taylor&White Inc.—Alex AcrP.E. 904134,6-/0671 �j f , Fee Simple Title Holder Name and Address A 1 G �'��{ �!d4� tW. .,v2{Fle►m►rt� 1'5lfittA1 Bonding Company Name and Address 1 Mortgage Lender Name and Address WNW 601X0—n!S � cl il 5 Ciat` W Y * p;�uC kSc>n tl i j IC,Q,�zZ gMgttgMgt2nNMors hereby made to obtain o permit to do the work and instlations as indicated I certify that no workor Installation has commenced suance ojo permit and that ail work will be performed to meet the slondards of ail taws regv/aling corutruclion in thisjurisdiction. ecomes mull and void If work Is not commenced wuhm sis(6 months,or tjconstrucllon or work is suspended or abandoned(or a (6)months of airy time after work is commented /understand that separate permits must besecured for Elec&icol Fork, ns,R'ells,Poole F7�rnaces,Ballets,Hearers,Tasks and Alt Condldontrt,etc WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that 1 have read and examined this application and know the same to be true and correct. Allprovisions,of laws and ordinances governing this ry of work will be complied with whether specified herein or not. Thei;ranling ofa permit does not resume to gtve authority to vrolate or can the provisions of arty other federal,state,or local law regulothrg cons ruclion or the performance 0)construUfon. Signature of Owner J �pSignauue of Contracto _ Print Name —Ai_ V I "...Print Name \ i t C� Sworn to and subscribed before me Sworn to and subscribed before me/ this/, Day of Aid vunbJr 2-01-2k— this 1A Day of �/ra��_7aA/1120 3 No P �c ri N ry Pu6iic o TAWAY MN,EY LEM$ Notary Public 'Stats of Honda �,,,�� JAvIrjttsMNNA+lAN s ,r My Comm.Expires Oct 20,2016 �$' Notary Public,State of Florida °? Commission 0 EE 211867 �* '" h�;;ti�°�• My Comm.Expires Mar.25,2016 n,•� Commission Na.EE 163470 Taylor Fr White, Inc. ko Consulting and Design Engineers 9556 Historic Kings Road S.,Suite 102-Jacksonville,Florida 32257 Tel:(904)346-0671 - Fax:(904)346-3051 www.taylorandwhfte.com Please Deliver to: Date: 11/13/2013 Project No.: 12210 City of Atlantico Beach Buildina Department Attention: Mr. Michael Griffin 800 Seminole Road Atlantic Beach. FL 32233 Re: Atlantic Beach Country Club (904)247-5814 Building Permit These documents are transmitted via: Express 1 Complete Plans Checklist 1 Building Permit Application Remarks: Mr.Griffin, Attached is the Building Permit Application and Checklist for the Civil Plan Approval of Atlantic Beach Country Club. This permit will be for the Civil Horizontal Permit only and does not include any of the vertical structures. Per Mr.Rick Carper,the recently submitted plans to the City of Atlantic Beach are acceptable for use with this Buiidin Permit Application. Please review and let me know if you need an additional information. Thanks, Signed: Alex R.Acree, P.E. Copies To: El File ❑ ❑ ❑ This tarsmission may contain information that is privileged or confidential. It s intended for the sole use of the individual or entity to whom a is addressed. It you have received this transmission In error,please cotfy us immediately by telephone and return the original message to us at the address below. if you are not the intended recipient of ttws message,or the employee or agont responsible for delivering the message to the intended recipient you are hereby notified that any dissemination.distribution or copying of this transmission is strictly prohibited. Taylor Fl White, Inc. Consulting and Design Engineers 9556 Historic Kings Road S.,Suite 102-Jacksonville,Florida 32257 Tel:(904)346-0671 - Fax:(904)346-3051 www.taylorandwhfte.com Please Deliver to: Date: 11/19/2013 Project No.: 12210 City of Atlantic Beach Building Department Attention: Mr. Michael Griffin 800 Seminole Road Atlantic Beach. FL 32233 Re: Atlantic Beach Country Club (904)247-5814 Building Permit These documents are transmitted via: Delivery 5 Final Engineering Plans Remarks: Mr.Griffin, Attached are 5 signed and sealed sets of the final engineering plans for Atlantic Beach Country Club. These plans reflect the recent comments from the City of Atlantic Beach Utilities. Per Donna,only 3 sets are needed for the City of Atlantic Beach however,we are including 5 sets as we will need at least 2 sets back that are stamped approved by the City of Atlantic Beach. Please let me know if you need any additional information. Thanks, Signed: Alex R.Acree, P.E. Received by: pl—print nartw signature Date: Time: Delivered by: C&- L70 Taylor E White, Inc. Consulting and Design Engineers 9556 Historic Kings Road S.,Suite 102-Jacksonville,Florida 32257 Tel:(904)346-0671 - Fax:(904)346-3051 www.taylorandwhfte.com TransTittal Please Deliver to: Date: 11/19/2013 Project No.: 12210 City of Atlantic Beach Building Department Attention: Mr. Michael Griffin 800 Seminole Road Atlantic Beach, FL 32233 Re: Atlantic Beach Country Club (904)247-5814 Building Permit These documents are transmitted via: Delivery 5 Final Engineering Plans Remarks: Mr.Griffin, Attached are 5 signed and sealed sets of the final engineering plans for Atlantic Beach Country Club. These plans reflect the recent comments from the City of Atlantic Beach Utilities. Per Donna,only 3 sets are needed for the City of Atlantic Beach however,we are including 5 sets as we will need at least 2 sets back that are stamped approved by the City of Atlantic Beach. Please let me know if vou need any additional information. Thanks, Signed: Alex R.Acree, P.E. Copies To: 0 File ❑ ❑ ❑ This transmission may contain information that is privileged or confidential. It is intended for the sole use of the individual or entity to whom it is addressed. If you have received this transmission in error,please notify us immediately by telephone and return the original message to us at the address below. If you are not the intended recipient of this message,or the employee or agent responsible for delivering the message to the intended recipient,you are hereby notified that any dissemination,distribution or copying of this transmission is strictly prohibited. PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: 2 G Initials:6� Project Name/Address: Application Permit#: Check Box Check Application Tracking Comments to Add Box to Comment "Print" UWSU Avoid damage to underground water/sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5834. MBSC Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. RT1C A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. RPZB A reduced pressure zone backflow preventer must be installed if irrigation will be provided or if there is a private well on the property. Backflow preventer must be tested 0 ❑ by a certified tester and a copy of the results sent to Public Utilities. STRM Plans note the building will be unsprinkled. If plans change, any fire line installed must be metered with a Sensus touch-read meter in a properly sized vault and an appropriate ❑ ❑ backflow preventer installed. Backflow preventer must be tested by a certified tester and a copy of the results sent to Public Utilities. FSBR If fire sprinkler system is provided, contact Malcolm Clemons at 247-5839 for backflow ❑ ❑ requirements. At a minimum, will require a double check backflow preventer. FLM Fire lines must be metered with a Sensus touch-read meter. Meters larger than 2" must be installed in a vault as noted in JEA specifications. `- 6 -chemo y� - cAa.,ve /" -w -e�-tv w s rce ❑ ❑ � 46e i'U✓ r l: 'p 'a yrs dr! ❑ ❑ ❑ ❑ ❑ ❑ 0 ❑ = - Taylor Z White, Inc_ Consulting and Design Engineers /1 9556 Historic Kings Road S.,Suite 102-Jacksonville,Flonda 32257 Tel-(904)346-0671 - Fax.(904)346-3051 www.taylorandwhite corn Z` Ans'mittal Please Deliver to: Date: 11/19/2013 Project No.: 12210 City of Atlantic Beach Building Department Attention: Mr. Michael Griffin 800 Seminole Road Atlantic Beach. FL 32233 Re: Atlantic Beach Country Club (904)247-5814 Building Permit These documents are transmitted via: Delivery 5 Final Engineering Plans Remarks: Mr. Griffin, Attached are 5 signed and sealed sets of the final engineering plans for Atlantic Beach Country Club. These plans reflect the recent comments from the City of Atlantic Beach Utilities. Per Donna,only 3 sets are needed for the City of Atlantic Beach however,we are including 5 sets as we will need at least 2 sets back that are stamped approved by the City of Atlantic Beach. Please let me know if you need any additional information. Thanks, Signed: Alex R.Acree,P.E`% Copies To: 0 File ❑ ❑ ❑ This transmission may contain information that is privileged or confidential. It is intended for the sole use of the individual or entity to whom it is addressed. If you have received this transmission in error,please notify,us immediately by telephone and return the original message to us at the address below. If you are not the intended recipient of this message,or the employee or agent responsible for delivering the message to the intended recipient,you are hereby notified that any dissemination,distribution or copying of this transmission is strictly prohibited. ' 1 APPLICATION NUMBER t�J 1 (To be assigned by the Building Depa nt.) 3 - /oo 0 97 7-5445 Date routed: 9 =W AND TRACKING FORM r;n C 1br ent review required Yes No B . Planning 8 Zoninal r inistrator F _ s Public Works -�—� -i lic UtilitlenD jar 0�1 67' fZ ZOO /OQ Public Safety / a� FlJ�` D T Fire Services Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B C tection l?d Q e ~ ,t District lk rd too U /-C �� n � ,d Tobacco m✓n P 7 ppLICATION STATUS �z Lpproved. [:]Denied- For S;O a te. S-�vi 2 11 1,:1G:s 0/1 T `'0,-0 r►t;,fi at,s oil. /tiv ~I t em r1 Ale- Reviewed by: Date: ) j uG k ,pproved as revised. ❑Denied. LiS r4 l Reviewed by: Date: ]Approved as revised. ❑Denied. 1 ' DK, Reviewed by: I D te: V V 1 .3: ., / ,: s r � BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 Job Address: 1600 SELVA MARINA DRIVE Permit Number: Legal Description See Attached Parcel# 169399-0000, 169399-0010 172024-0000 Floor Area of Sq.Ft. Sq.Ft Valuation of Work$ 6M Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed?(Circle one): Yes S N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: The re-development of the existing Selva Marina Golf Course and Country Club with the addition of un to two hundred(200)single-family lots with associated utilities and stormwater management system. Property Owner Information: Name:Atlantic Beach Partners,LLC Address: 414 Old Hard Road,Suite 502 City Fleming Island State FL Zip 32003 Phone (904)264-6553 E-Mail or Fax#(Optional) rwoodaa.wooddev.net Contractor Information: Company Name: Barco-Duval Engineering,Inc. Qualifying Agent: Ron Price Address: 7587 Wilson Blvd. City Jacksonville State FL Zip 32210 Office Phone_(904)772-1313 Job Site/Contact Number Fax# (904)771-7912 State Certification/Registration Architect Name&Phone# Cronk Duch Architecture—Cliff Duch,ICAA.A.I.A.(904)302-9848 Engineer's Name&Phone# Taylor&WhiteInc.—Alex Acree P.E.(904)346-0671 I ' r Fee Simple Title Holder Name and Address tart A c- ck er�L(.L,-fF t Old 4(1fd Rd.�5�2,Fie,,,) - 5/C Ad /'/• Bonding Company Name and Address Mortgage Lender Name and Address 0 1 • 0 u o ( VLL[ qq q 5 Ctalr-Pkw y Aioo.To1—kSvw; IP,p, 31 Z Application is hereby made to obtain a permit to do the work and installations os indicated. /certify that no work or installation has commenced poor(o the issuance oja penin"and that a!I work will be performed to meg!the standards ojal!/aws regulating construction in this jurisdiction. This permi!becomes md!and void ijwork is not commenced wn six(6 months,or if construction or work�s suspended or abandoned/or a period of six(6j months at arty time after work is commenced. 1 understand that separate permits must be secured for Electrical Work, P/ambing,Signs,W I ,Pools,Furnaces,Boilers,Netters,Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certt&that 1 have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting oja permit does not resume to give authority to violate or cancel the provisions ojany other federal,state,or local law regulating construction or the performance o�corutructton. City of Atlantic Beach APPLICATION NI MBER JS �� Building Department (To be assigned by the Build ng Department.) > F� v 800 Seminole Road _ lee D g s� Atlantic Beach, Florida 32233-5445 �— Phone(904)247-5826 • Fax(904)247-5845 / p �Ji31�r E-mail: building-dept@coab.us LDate routed: 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 a J41110- ;V 24rin A. 1�1De ent review required Yes No Applicant: �/� .7'1 (el 2ja.nnin 4ong' &Zng Tre. inistrator Project: / A Public Works ublic Utilitie 0 •� C� /I/ Z 7- Public Safety Fire Services l J Review fee $ ,y 7 }# e ( i n cZ i � 9� Other Agency Review or Permit Required Review or Receipt Date SnV ire of Permit Verified B Florida Dept. of Environmental Protection wd a S Florida Dept. of Transportation St. Johns River Water Management District �,C tt��r'C�rQ(L".0 Army Corps of Engineers 1 Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. [:]Denied. (Circle one.) Comments: `` � BUILDINGC7'kTS i /'�V��.�- ►'�T�` - 9 Y S_ 13 Reviewed by: Date: I �e11 n ]Approved as revised. ❑Denied. it Reviewed by: Date: a P ]Approved as revised. ❑Denied. Reviewed by: Date: I Revised 05/14/09 BUILDING PERMIT APPLICATION -- CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 DEC 17 2013 i � Office (904) 247-5826 Fax (904) 247-5845 t Job Address: Permit Number: Legal Description Parcel# Floor Area of Sa.Ft. Sq. t Valuation of Work$ 5,-732,111 I .� Proposed Work heated/cooled 1�� GIZ non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): mere Residential If an existing structure,is a fire sprinkler system installed. ircle one): Yes No N/A Florida Product Approval # For multiple products use product approval form Describe in detail the type of work to be performed: UFf U1-f6,1 Property Owner Information: Name:Selya Mavw\o. Czu-n: � Gu»; \v\ . Address: IwOO Sal-Jo.- rrc;..vxy%c... Zr. City 1A*1txv\tic_ State L,Zip A *13 Phone cto4- A-1Z_ - Z7-2--7— E-Mail Z.ZZE-Mail or Fax#(Optional) Contractor Information: Company Name: RPC_ e eytiv ekA C'rr� c.�ra, ►•-<-.Qualifying Agent: 1�et� J • Qc v�ca�re s Address: 2 N'�e L \fU e-cl City t)4lan-tic, -6ey,c State y-L— Zip S z 33 Office Phone RUN- 2y1- +11 �.o Job Site/Contact Number RpN- gy5-6� \► Fax# q C»-1— ?J�►-y421 State Certification/Registration# GGG Oui ow 1q Architect Name& Phone# Cki V-f 1D0.c.1n (1104) 3D2- Ok?LI$ Engineer's Name& Phone# -* V -52_C>0 Fee Simple Title Holder Name and Add ess Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. /certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void rf work is not commenced within six(6)months, or if construction or work is sus ended or abandoned for a period ojsix(6)months at any time after work is commenced. /understand that separate permits must be secured for Electric Work, Plumbing,Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. /hereby certify that/have read and examined this application and know the same to be true and correct. All provuiohs pf s d ordina s verning this type o work will be complied with whether specified herein or not. The granting of a permit does not presume't tv a ori to or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Owner 4C)0=6�1 Signature of Contractor Print Name .WDoc Print Name -1 'C .....:� �.�..�. �. 1 ............................. Sworn to and subscribed before me Sworn to and subscribed before me this Day of 111mel, L,r%- ,20/3 this Day of 20 t3 Notary Public Nota Public Revised 01.26.10 .iKifIII CATHERINE LEWIN 's Notary Public- State of Florida My Comm.Expires Apr 23,201T �'"�T:, $HAN11 MMSTEER s1, :� 4.� Commission#FF 011275 _ . MY COMMISSION#EE045088 EXPIRES November 28,2014 (4037396-0153 Florida Aom BUILDING PERMIT APPLICATION FPDEC u TCITY OF ATLANTIC BEACH800 Seminole Road, Atlantic Beach, FL 32233013 Office (904) 247-5826 Fax (904) 247-5845 Job Address: /.�1k, ' Permit Number: Legal Description Parcel# Floor Area of Sq. t. Sq.Ft Valuation of Work$ 5t-73Z,'I l►•vD Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): merci Residential If an existing structure,is a fire sprinkler system installed, ircle one): Yes No N/A Florida Product Approval # For multiple products use product approval form Describe in detail the type of work to be performed: 6ou rt f eQ 61..46 Property Owner Information: Name:Seku Mavw\C. Cay�t,n-1 Address: 1%000 SGI-/4.. City A+lav\yLc_ -6coc \ State ( Zip 32233 Phone OtoLt- S-tz- ZZZ.ZZ E-Mail or Fax#(Optional) Contractor Information: Company Name: R+Pf_ C-►eq-�&_ryAu Cu-,yy-o %, Qualifying Agent: Pe-t-in.,e- 3 . QoAnGye.S Address: 2_4'�- L \rd lJ • City A�kcunric, t3cn► State F L— Zip 32233 Office Phone qoN- __—Job Site/Contact Number QuN- Fax# clo1-1- 2At_4.42-i State Certification/Registration# Gai; Ou-1CDw tq Architect Name& Phone# Cki-V-F Vb t> t (LIOLJ) aD2- Ok?4 9 Engineer's Name& Phone# -* V -5 2-CZ::) Fee Simple Title Holder Name and Add ess Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. l certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for apertod ojsrx(6)months at any time after work is commenced. l understand that separate permits must be secured for Electrical Work, Plumbing,Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that l have read and examined this application and know the same to be true and correct. All provcrions 9f s d ordina s verning this type o work will be complied with whether specified herein or not. The granting of a permit does not presume't tv a ori to or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Owner Signature of Contractor Print Name �I� WO .................................................... Print Name " 'C�......: xJ +.C�4a 5.................................._............... .................. ............................................ Sworn to and subscribed before me Sworn to and subscribed before me this}ALI'' /Day of Z2dQ1 b , 20/3 this G Dayof 20(s Notary Public Notary P" 6-_66 Revised 01.26.10 CATHERINE LEWN Notary Public-State of Florida rr,: �.My Comm.Expires Apr 23.2o1T ; SHANE MINISTER Commission#E FF 011275 A MY COMMISSION#EE045088 EXPIRES November 28.2014 01 (407)396-0163 ftwideNawry3oryloam - � � <. ILDING PERMIT APPLICATION FILEC-�� Y CITY OF ATLANTIC BEACH 8 Seminole Road, Atlantic Beach, FL 32233DEC 17 2013 *�,.r�•rte ffice (904) 247-5826 Fax (904) 247-5845 _ Job Address: _� �o d D S P-VA IA,441 r(,4 P Permit Number: Legal Description ATT 4L-N to Parcel # - Floor Area of'—3q.t. 'q't Valuation of Work S 5, 3 2,1:111 .Le Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): e�w Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): merct Residential If an existing structure,is a fire sprinkler system installed. ircle one): Yes No N/A Florida Product Approval # For multiple products use product approval form AA Describe in detail the type of work to be performed: A raw A t 4nj 7 t i� t_a Property Owner Information: Name:S'elva Mavly\a Cctxy-\t n- Gu,\,O, \Y\.c. Address: IWL70 SaJvgL- City la+_lCay\tiC_ StatejZip 32233 Phone otoq- x-IZ- ZZZZ E-Mail or Fax# (Optional) Contractor Information: Company Name: Ree_ Cacyy—_,,­c.c. ca. << knc, Qualifying Agent: Pette J Address: 2L1�k Le\.l\ Q.LI . City t)-4lcaMk_ State F L Zip 322Y33 Office Phone qDN- 2412 H41 w Job Site/Contact Number got4- gy5-5,_�j 1 l Fax# cAVta— 2{t-gL4z-j State Certification/Registration # CGG C)LiOln lq Architect Name& Phone # Cki-V-F Dy�cy-\ (110Lj) CD2- 0%kL4 9 Engineer's Name& Phone# Mc_V2►4h - Mcwyj E �v�e��✓Cv,c.. ('TO4) Lok&-52C>0 Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated l certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6)months at any time after work is commenced l understand that separate permits must be secured for Electrical Work, Plumbing,Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that l have read and examined thi'sapmeplication and know the same to be true and correct. All prov eons 9f s d ordinan s verning this type o1 work will be complied with whether specified herein or not. The granting of a permit does not presut iv a ori to or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. t Signature of Owner G0 4c)_0=6�1 Signature of Contractor PrintName !. .......... F....................................................... Print Name ......� 'ZC t. -� 5................................................... Sworn to and subscribed before me Sworn to and subscribed before me this" Day of 1)e6e Mba*/ 2U3 this Day of 20 Is Notary Public N Pu lic Revised 01.26.10 .•�'�P� .•� �e°�,� CATHERINE LEWIN . Notary Public-State of Florida - liy o�a My Comm.Expires Apr 23,2017 r '�r• aMANE PcEMSTER Commission#FF 011275 •'� MY COMMISSION#EE045088 EXPIRES November 28,2014 (407)398-0133 FIONeNow ervicefom From:9047371099 08/22/2014 10:35 #685 P.002/002 EARLY POWER AGREEMENT & RELEASE J CITY OF ATLANTIC BEACH Electric power is requested now under the conditions and terms of this fully executed Agreement& Release Job Address: Permit No. Cr CO zJc `t b Service Type(Circle One) O�he Underground We,the undersigned General Contractor and Electrician,understand and agree: 1. "Early Power" is purely for our construction convenience, it is not required by Codes and does not substitute for Final Inspections or the C/O(Certificate of Occupancy']mat must be issued before occupancy, and as such is at the discretion of the Building Official. 2. The City of Atlantic Beach will make a special inspection prior tothe early power energizing. All rough inspections must have prior Approval,including meter base connections. 3. Occupancy or use of the new construction before a formal C/O constitutes fraudulent use of the early electric service. Such action is expressly prohibited and penalized by The City of Atlantic Beach Ordinances. A violation of this Agreement shall result in a request for prompt removal of electric service after a twenty-four hour notice. 4. "Early Power"release authority is the Electrician and/or the Contractor and must not occur before: a. Equipment,devices and fixtures are installed(or blanked off)safely. b. Panel is complete with breakers and cover,and(labeling required at final inspection). c. Service connection and grounding is complete. d. The electric system has safely passed through electrical check. e. Meter can is permanently marked with address. f. Temporary address numbers displayed(Permanent numbers are required for C/O). 5. This fully completed form is to be submitted to the Building Department by hand,mail or fax. 6. Future such Agreements will not be accepted from those who violate any one of the above items. CONTRACTOR 1 Cwt 1(JC&' DATE PRINT NAME ELECTRICIAN � DATE PRINT NAME 800 Seminole Road,Atlantic Beach FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 http://www.coab.us revised 01 30 09 •, MOVE IGH&MANGUM ENGINEERI N G • INC TRANSMITTAL LETTER To: Dan Arlington Date: November 5, 2014 City of Atlantic Beach Building Official 800 Seminole Road Atlantic Beach, FL. 32233 Project: Atlantic Beach Country Club— MME Job #: 14025 Threshold Inspection Services We transmit: (x) herewith ( ) under separate cover Delivery Method: (x) Mail ( ) FedEx Tracking# ( ) Courier- Ticket # ( ) Other For your: ( ) approval ( ) review& comment (x) use The following: 1 Bound Atlantic Beach Country Club—Threshold Inspection Services (Final Letter) STRUCTURAL - MECHANICAL • ELECTRICAL • PLUMBING - LEED • COMMISSIONING BIM 1955 Lake Park Dr.SE•Suite 325•Smyrna,GA 30080• (678)213-1616• www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL MCVEIGH&MANGUM E N G I N E E R I N G - I N C October 29,2014 Mr. Dan Arlington City of Atlantic Beach Building Official 800 Seminole Road Atlantic Beach, FL 32233 Dear Mr.Arlington, Re: Atlantic Beach Country Club—Threshold Inspection Services(Final Letter) Jacksonville, FL. Permit No. 13-3848 MME# 14025 To the best of my knowledge and belief, the above described construction of all structural load-bearing components com ,ylk the permitted documents as required by the threshold inspection plan. Il Sincerely ,...... •..���'��,, JS Ti OA¢en,P.E. DEED AP Thresl't�'il�erc&r ofAdkold FloridaV' Pro es onaj• deer License#52735 Florida ch�`lr�A'5" ga'�41161 UNAL f, Distribution to: Building Officials: Owner: Contractor: City of Atlantic Beach Atlantic Beach Partners RPC General Contracting Inc. Dan Arlington Rick Wood Pete Rodrigues darlington@coab.us rwood@wooddev.net pete@rpcgc.com Susan Wood Mike Jones swood@wooddev.net Danny Rodrigues mjones@coab.us danny@rpcgc.com Architect: Shirley Graham Croak Duch Architecture Jennifer Snow sgraham@coab.us Cliff Duch Jennifer@rpcgc.com cliff@arch-cd.com Jennifer Walker jwalker@coab.us Engineer: McVeigh&Mangum Engineers,Inc. Tim W.Owen,P.E towen@mcveighmangum.com STRUCTURAL MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL �64 �4# MCVEIGH&MANGUM E N G I N E E R I N G - I N C October 29,2014 Mr.Dan Arlington City of Atlantic Beach Building Inspection Division 800 Seminole Rd. Atlantic Beach, FL 32233 Dear Mr.Arlington: Re: Atlantic Beach Country Club-Threshold Inspection Services Atlantic Beach, FL Permit No. 13-3848 MME Project#14025 Enclosed is the threshold material for the captioned project relating to inspections performed for the month of June through September 2014. uun�nn�y�� Sincerely, W. O '' • SCE•'' �F��k'. • ••. 2' No. 735 •: Tim W.O�Be �.E., LEED A S Threshol*uy' ding I ecr of Recora License N4. -%5 ATE of •.•' r; Florida Regie�Ile, •• ctot'l.�A61 "II4s%�0NAL 040�t.S%NON ,'�yr14rii101hflOttrittEtt email: Dan Arlington(darlington@coab.us) Mike Jones(mjones@coab.us) Shirley Graham(sgraham@coab.us) Jennifer Walker(jwalker@coab.us) Susan Wood (swood@wooddev.net) Rick Wood (rwood@wooddev.net) Cliff Duch(cliff@arch-cd.com) Pete Rodrigues(pete@rpcgc.com) Bob Grant(bobg@rpcgc.com) Jennifer Snow(jennifer@rpcgc.com) STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL �6*�# MOVE IGH&MANGUM ENGINEERING - I NC STATEMENT OF THRESHOLD INSPECTOR Atlantic Beach Country Club Atlantic Beach, FL June-September 2014 The undersigned Special Threshold Inspector verifies that I have reviewed all of the test data which has been supplied to me relating to this project during this month and have found them to be in compliance with the project requirements,except as noted below. DEFICIENT TEST RESULTS CORRECTIVE ACTION COMPLETED(x) None Further,to the best of my knowledge and belief,the described construction of all load-bearing components complies with the permitted documents submitted to the enforcement agency with the exception of any deficiencies outlined in the enclosed deficiency log. O N� ��yY • .••••••� • �4t, Tim W. O E.:• ' 0.82733 _ Threshold Budin$Inspector*f Record License No.: VlHS• S7AT Florida Regist;E�l Insped r NP 11 s �yy� NAL STRUCTURAL MECHANICAL ELECTRICAL • PLUMBING • LEED • COMMISSIONING BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL '�6*�# MCVEIGH &MANGUM ENGIN E E R I N G • INC Atlantic Beach Country Club Atlantic Beach, FL June-September 2014 018 Observed remainder of roof sheathing attachment at pool building and fitness center. Observed framing,strapping and sheathing attach- ment at all dormers at pool and fitness building. Observed framing,strapping and sheathing attach- ment over flat roof at bar per section 3/54.2. Observed roof sheathing and gable and sheathing attachment on northside of clubhouse. 019 Observed corrections to 012-1 Observed clips and sheathing attachment at 3 low roofs at the clubhouse. Observed framing at 3 low roofs at the clubhouse. Observed truss clips at pool and fitness buildings. Observed wall attachment detail at kitchen in clubhouse shown in details 6 and 11 on 54.1. 020 Observed strapping at tower and wall sheathing attachemnt at curved wall and remainder of West side. 021 Observed sheathing attachment at bumpout at base of tower. Observed correction to 020-1 and 014-1 022 Observed window attachments 023 Observed roof sheathing attachment at entry tower 024 Observed sill plate attachment at SW3 at kitchen. Observed correction to 019-1 Continued on next page STRUCTURAL MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL 025 Observed sill plate attachment at remainder of outside wall at clubhouse. Observed correction to 023-1,023-2,024-1. 026 Observed sill plate attachment at interior load bearing walls at clubhouse. Observed correction to 014-2,and 025-1. Observed sheathing attachment at interior shear walls. 027 Observed sill plate attachment at exterior and interior load bearing walls at pool and tennis building. Observed correction to 026-1. Observed sheathing attachment at interior shear walls at pool and tennis building. 028 Observed correction to 027-1,and 027-2. STRUCTURAL MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL MCVEIGH&MANGUM E N G I N E E R I N G - I N C THRESHOLD INSPECTION CONSTRUCTION DEVIATION &CORRECTION LOG Project: Atlantic Beach Country Club MME Project No. 14025 Location: Atlantic Beach, FL Required Report No.Item Description of Construction Deviation* Corrective Date Date i No. Observation Correction Action 005-1 One anchor did not achieve sufficient depth 4/9/2014 4/30/2014 due to rebar in the way.Contact EOR for fix. 012-1 One roof opening at kitchen not framed per 5/15/2014 6/18/2014 details.Contact EOR for fix. 014-1 Clips missing below the plate at south end 5/22/2014 6/27/2014 girder. 014-2 Clips missing on lower part of X-braces. 5/22/2014 8/6/2014 019-1 Sheething in stud cavities still needs to be added at 6/18/2014 7/23/2014 kitchen walls. 020-1 Strapping needs to run stright. 60/20/2014 6/27/2014 023-1 Nails missing at top plate clip on east side dormer. 7/10/2014 8/5/2014 023-2 Straps missing on south side stair beam. 7/10/2014 8/5/2014 024-1 Two shear blocks missing in mechanical room at NE corner. 7/23/02014 8/5/2014 025-1 Anchor bolts missing at various locations. Locations 8/5/2014 8/6/2014 noted in the field. Call for reinspect when completed. 026-1 Need to add DTT2 holdown at stud pack at left side 8/6/2014 9/9/2014 of door under stairs. 027-1 Anchor bolts missing at various locations 9/9/2014 9/10/2014 marked in field. 027-2 Sheerwall nailing incomplete. 9/9/2014 9/10/2014 STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL MOVE IGH&MANGUM r N G I N E E R I N G - I N C THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners,LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach,FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D.Mangum,P.E. REPORT NO.: 018 CONTRACTOR: RPC General Contractors, Inc. INSPECTION: PERSONNEL PRESENT: DATE: 6/4/2014 Mike Johnson-MME TIME: 2:15 pm-4:30 pm Bob Grant-RPC WEATHER CONDITIONS: 90 +± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed remainder of roof sheathing attachment at pool building and fitness center. Observed framing,strapping and sheathing attach- ment at all dormers at pool and fitness building. Observed framing,strapping and sheathing attach- ment over flat roof at bar per section 3/S4.2. Observed roof sheathing and gable and sheathing attachment on northside of clubhouse. DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: No deficiencies observed. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 012-1 One roof opening at kitchen not framed per details. Contact EOR for fix. STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL a 014-1 Clips missing below the plate at south end girder. 014-2 Clips missing on lower part of X-braces. REMARKS: Respectfully SUb�inP S % McVeigh& Vlangbmngineerin , I* No.5273 3 TATE OF ; Q Tim W.Owet .;.j APR Threshold BuiN!,'r dr},s License No.:527Y /ONM- ����a Iml/Illll Florida Registered Special Inspector No.: 1161 Mike Johnson, E.I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Mike Griffin pete@rpcgc.com rwood@wooddev.net mgriffin@coab.us Bob Grant Susan Wood Mike,Jones bobg@rpcgc.com rwood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL MCVI--IGI-l&MANGUM IINGI N I t k I N 6 . I \ C THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners,LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach,FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D.Mangum,P.E. REPORT NO.: 019 CONTRACTOR: RPC General Contractors,Inc. INSPECTION: PERSONNEL PRESENT: DATE: 6/18/2014 Mike Johnson-MME TIME: 2:30 pm-4:45 pm Danny Rodrigues-RPC WEATHER CONDITIONS: 90 -F± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed corrections to 012-1 Observed clips and sheathing attachment at 3 low roofs at the clubhouse. Observed framing at 3 low roofs at the clubhouse. Observed truss clips at pool and fitness buildings. Observed wall attachment detail at kitchen in clubhouse shown in details 6 and 11 on S4.1. DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMEN DEDCORRECTIVE ACTION: 019-1 Sheething in stud cavities still needs to be added at kitchen walls. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 012-1 One roof opening at kitchen not framed per details. X Contact EOR for fix. STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE,FL 014-1 Clips missing below the plate at south end girder. 014-2 Clips missing on lower part of X-braces. REMARKS: Respectf, At�ri �■�•�..4i� McVe i &1�6)a ' EngTode*g,I No.52735 Tim V1F. Q Threshcl J �'d:OR49t$Y+ rd �. License N � NA1 ��G\�• Florida RegistePW*4" t4dMl pector No.: 1161 t^ Mike Johnson,fl. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Mike Griffin pete@rpcgc.com rwood@wooddev.net mgriffin@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwall<er@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL A*V MC\/i:lG1-i&MANGUM I X f; I X I 1 P 1 N I N C THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners, LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach, FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D. Mangum, P.E. REPORT NO.: 020 CONTRACTOR: RPC General Contractors, Inc. INSPECTION: PERSONNEL PRESENT: DATE: 6/20/2014 Mike Johnson-MME TIME: 3:30 pm-4:00 pm Danny Rodrigues-RPC WEATHER CONDITIONS: 95 -F± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed strapping at tower and wall sheathing attachemnt at curved wall and remainder of West side. DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: 020-1 Strapping needs to run stright. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) STRUCTURAL • MECHANICAL - ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE, FL 014-1 Clips missing below the plate at south end girder. 014-2 Clips missing on lower part of X-braces. 019-1 Sheething in stud cavities still needs to be added at kitchen walls. REMARKS: 0%j%1" oil/ Respec ully vJS�� •'•.�� , �. . McV gh 8fJ�/langum Errg'ineehng, fgc. .527 5 Its S t, Tim LEE kP�e / Thresh !No.% A 14, cord License At�� l i �M Florida RegisterMjTtla�Inspector No.: 1161 Mike Johnson, E.I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Mike Griffin pete@rpcgc.com rwood@wooddev.net mgriffin@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcRc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.corn STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL MC\/I:IGI-Ic)MANGUM 3 K I I It J A G I N C THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners,LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach, FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D. Mangum,P.E. REPORT NO.: 021 CONTRACTOR: RPC General Contractors,Inc. INSPECTION: PERSONNEL PRESENT: DATE: 6/27/2014 Mike Johnson-MME TIME: 2:00 pm-2:30 pm Danny Rodrigues-RPC WEATHER CONDITIONS: 95 -F± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed sheathing attachment at bumpout at base of tower. Observed correction to 020-1 and 014-1 DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: No deficiencies observed. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL 014-1 Clips missing below the plate at south end girder. X 014-2 Clips missing on lower part of X-braces. 019-1 Sheething in stud cavities still needs to be added at kitchen walls. 020-1 Strapping needs to run stright. X REMARKS: p1NININNI//yy/ Respectfu� :ft'tl:dr 0 McVeigh*t M•gnuu, `` g, C. ._ o, "IV 2735 '' im\AFltp�F Threshk1 �g Inspectpr PP ` '' '' RID o` License N: 5..•„•••.. �C1``�� Florida Regis�Y� i AiaC�►�s�j6t`�or No.: 1161 '/ll/unuuu+naaa� Mike Johnson, E.I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach,FL Pete Rodrigues Rick Wood Mike Griffin pete@rpcgc.com rwood@wooddev.net mgriffin@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com rwood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL �t MCVEIGH&MANGUM rS, 61NI IP, IN . INC THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners, LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach,FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D. Mangum,P.E. REPORT NO.: 022 CONTRACTOR: RPC General Contractors,Inc. INSPECTION: PERSONNEL PRESENT: DATE: 6/30/2014 Mike Johnson-MME TIME: 2:30 pm-4:00 pm Danny Rodrigues-RPC WEATHER CONDITIONS: 90 +± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed window attachments DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: No deficiencies observed. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 014-2 Clips missing on lower part of X-braces. 019-1 Sheething in stud cavities still needs to be added at kitchen walls. REMARKS: STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING - LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL {\\\1{wit IIIIIIII III 111!!I Respe`'ully � Mcv fgh angum' ngieering,f}�c. 0 3$ ' E Tim A►2A E. LEED,AP'. Thresh t +C` cord License No'yi Florida Registered'S` �iJ)�'�Inspector No.: 1161 Mike Johnson, E:I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Mike Griffin pete@rpcgc.com rwood@wooddev.net mgriffin@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA, GA • CHARLOTTE, NC • JACKSONVILLE, FL i Y , } 2014/06/20_ g 3 E: 14/06/27 t M q. h s MCVEIGH&MANGUM I INGINI I. R I N G • INC THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners, LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach, FL ARCHITECT: Cronk& Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D. Mangum, P.E. REPORT NO.: 023 CONTRACTOR: RPC General Contractors, Inc. INSPECTION: PERSONNEL PRESENT: DATE: 7/10/2014 Mike Johnson- MME TIME: 2:15 pm-2:45 pm Danny Rodrigues-RPC WEATHER CONDITIONS: 85 °F± overcast GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed roof sheathing attachment at entry tower DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: 023-1 Nails missing at top plate clip on east side dormer. 023-2 Straps missing on south side stair beam. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 014-2 Clips missing on lower part of X-braces. 019-1 Sheething in stud cavities still needs to be added at kitchen walls. STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL REMARKS; ,,,jj1;NµN t t 1 itHl(IItN' Respec,4 w Eo McVgfi0 en Inc. s 35 ' TiA W• e11 6 50JAP :Lt Thr% 'dud ng I�n,A�tc7f o-*cordV LicenSe,�raa `� 2. .•••L��� �� . Florida ff' IONM iM�,-Kector No.: 1161 'a'I+�Hnwml�Nov<< Mike Johnson, E.I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Dan Arlington pete@rpcgc.com rwood@wooddev.net darlington@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL PLUMBING LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.rncveighmangum.com ATLANTA, GA • CHARLOTTE, NC • JACKSONVILLE, FL MV! MCVEIGH&MANGUM E N G I N I I R I N G - I N C THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners, LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach, FL ARCHITECT: Cronk& Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D.Mangum, P.E. REPORT NO.: 024 CONTRACTOR: RPC General Contractors, Inc. INSPECTION: PERSONNEL PRESENT: DATE: 7/23/2014 Mike Johnson- MME TIME: 10:30 AM-11:00 AM Danny Rodrigues- RPC WEATHER CONDITIONS: 85 °F± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed sill plate attachment at SW3 at kitchen. Observed correction to 019-1 DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: 024-1 Two shear blocks missing in mechanical room at NE corner. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 014-2 Clips missing on lower part of X-braces. 019-1 Sheething in stud cavities still needs to be added at kitchen X walls. 023-1 Nails missing at top plate clip on east side dormer. 023-2 Straps missing on south side stair beam. STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL REMARKS: tit+N 1 Respectfultoltltp�i McVeist )t 0.rlgurvY r �¢ hi% Inc. •••••V�Ci E ��'••• ryr No.52735 Ti . ©wen, P.E., EED AP 7F Th •Bu` TATrzs0Ftov%Re#ord Lice FIorid l � 3�•Ptyd- elf Idlq for No.: 1161 ON L 11►1fut1 riiti,iiii Mike Johnson, E.I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Dan Arlington pete@rpcgc.com rwood@wooddev.net darlington@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA, GA • CHARLOTTE, NC • JACKSONVILLE, FL } 5 2014/0T/10 f; --2014/07,/10 w- :;�.�., -�. ,, .. fi �,� .�., g z,.. �,� :��., .� ,�x- , . ,,. _ ...� A� x. _; _ �. �1 _, ___._.��_ _�._ �- ��.�_n� _� + � �. , �� ,_ � , a �.•a. ' tt �� a¢� ��fl�l� .iu -... '�� 1 .:- .,� �� -,, 1 `��. r _. ;t � � .. .� ,. .. ,� ,. a_ �. :� ` . � n. ��:� ,_� r ---_,.�� _ p�0 � .,�r t. �, � � _� „. , �N iii r ��' ii t �� 7 � � ,Fr_ fly �I� 111 ..c.• _ ,.--_ �_ _. ---- --_�_ __�..� MCVEIGH&MANGUM f N G I N r I R I N G I N C THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners, LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach, FL ARCHITECT: Cronk& Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D. Mangum, P.E. REPORT NO.: 025 CONTRACTOR: RPC General Contractors, Inc. INSPECTION: PERSONNEL PRESENT: DATE: 8/5/2014 Mike Johnson-MME TIME: 3:30 PM-5:00 PM Danny Rodrigues- RPC WEATHER CONDITIONS: 95 °F± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed sill plate attachment at remainder of outside wall at clubhouse. Observed correction to 023-1,023-2,024-1. DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: 025-1 Anchor bolts missing at various locations. Locations noted in the field. Call for reinspect when completed. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 014-2 Clips missing on lower part of X-braces. 023-1 Nails missing at top plate clip on east side dormer. X 023-2 Straps missing on south side stair beam. X 024-1 Two shear blocks missing in mechanical room at NE corner. X STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE, FL REMARKS: ,�,',iNH11111i1NN111,1�//'t/ Res pe�l� IG��tejr'r/ Mc ng erirfp,Inc. v : s Tir- ©wen,�'�0L P•• 44 Thr :I "L1°��'• cord Licens S... ftl� Florida Re � ispector No.: 1161 Mike Johnson, E.I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Dan Arlington pete@rpcgc.com rwood@wooddev.net darlinBton@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www,mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL IMut- MCVEIGH &M F NGI N l t P I N (. I N l THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners, LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach, FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD: Wayne D. Mangum, P.E. REPORT NO.: 026 CONTRACTOR: RPC General Contractors, Inc. INSPECTION: PERSONNEL PRESENT: DATE: 8/6/2014 Mike Johnson-MME TIME: 3:30 PM-5:15 PM Danny Rodrigues- RPC WEATHER CONDITIONS: 95 °F± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed sill plate attachment at interior load bearing walls at clubhouse. Observed correction to 014-2,and 025-1. Observed sheathing attachment at interior shear walls. DEVIATIONS/DEFICIENCIES OBSERVED& RECOMMENDEDCORRECTIVE ACTION: 026-1 Need to add DTT2 holdown at stud pack at left side of door under stairs. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 014-2 Clips missing on lower part of X-braces. X 025-1 Anchor bolts missing at various locations. Locations X noted in the field. Call for reinspect when completed. STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL REMARKS: ,``pU,��nuu�nnlanrkrp�r• Respect I 't, �41�Js•• • 'a McVeigh&4+?an um Engineernjg, IrrE. 7.35 cF OW3 Tim W. N.Pk LEED Ali , Thresho�&.. r1Je� ,o� rd License No.gZ3 ;!rJNA1-� rnrr � Florida Registered'l��r@�1"a���finaspector No.: 1161 &Z Mike Johns n, E.I. Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Dan Arlington pete@rpcgc.com rwood@wooddev.net darlington@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D. Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL - MECHANICAL ELECTRICAL - PLUMBING • LEED COMMISSIONING BIM 9133 R.G. Skinner Parkway Jacksonville, FL 32256 • (904) 483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE, NC • JACKSONVILLE, FL � v s .ti F u i yy��III �, .��. �}} f Irv. ._ .�..�: 1 � i• 1 • � m }g �� � f � ���,�"`~•� .. .. _.a tel•�' n. ��' -� ,_irM r - IUIuVV r � 8g < .m e+v IMP!, MCVEIGH&MANGUM E tv C; I N r t. R I N G - I N C. THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners,LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach,FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D.Mangum,P.E. REPORT NO.: 027 CONTRACTOR: RPC General Contractors,Inc. INSPECTION: PERSONNEL PRESENT: DATE: 9/9/2014 Mike Johnson-MME TIME: 3:00 PM-4:00 PM Danny Rodrigues-RPC WEATHER CONDITIONS: 85 °F± Overcast GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed sill plate attachment at exterior and interior load bearing walls at pool and tennis building. Observed correction to 026-1. Observed sheathing attachment at interior shear walls at pool and tennis building. DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: 027-1 Anchor bolts missing at various locations marked in field. 027-2 Sheerwall nailing incomplete. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 026-1 Need to add DTT2 holdown at stud pack at left side X of door under stairs. STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL REMARKS: ,�„ttaluulrl!u!p •�' Ott' ..... ��t �i� Resp� fikl�� !� Mc igh M?nigu�ttm E "ng, C. s 6 WS E P a .00 r Q` ThrA,h-4 1,� ;pt cord LicensrssJ�le �735�• •' �� `� Florida Itic��ector No.: 1161 •rpNIHlltlltt Mike Johnson,E-r.' Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach, FL Pete Rodrigues Rick Wood Dan Arlington pete@rpcgc.com rwood@wooddev.net darlington@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D.Mangum,P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL MCVEIGH&MANGUM r N G I N [ ! R I N G - I N C THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners,LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach,FL ARCHITECT: Cronk&Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD:Wayne D.Mangum,P.E. REPORT NO.: 028 CONTRACTOR: RPC General Contractors,Inc. INSPECTION: PERSONNEL PRESENT: DATE: 9/10/2014 Mike Johnson-MME TIME: 3:30 PM-4:30 PM Danny Rodrigues-RPC WEATHER CONDITIONS: 90 -F± Clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed correction to 027-1,and 027-2. DEVIATIONS/DEFICIENCIES OBSERVED&RECOMMENDEDCORRECTIVE ACTION: No deficiencies observed STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) 027-1 Anchor bolts missing at various locations X marked in field. 027-2 Sheerwall nailing incomplete. X STRUCTURAL • MECHANICAL • ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville,FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL REMARKS: `\�nlnnuua(tfu�/IN,Ip'arr Respec � ��•�`� 'Y'����'. McVe h&Walr 4 En No.,Ww Tim �� V4J(. �; Q, Thres�4?;( l�df+glti�p�t�r�pf�$ d License ..•....., i \ e`A� Florida [ e!i;i ig til { �tor No.: 1161 /r//I/I(1I1 t 0111111/N Mike Johnson,ef Distribution: Owner: Building Officials: Contractor: Atlantic Beach Partners City of Atlantic Beach,FL Pete Rodrigues Rick Wood Dan Arlington pete@rpcgc.com rwood@wooddev.net darlington@coab.us Danny Rodrigues Susan Wood Mike,Jones Danny@rpcgc.com swood@wooddev.net mjones@coab.us Jennifer Snow Architect: Shirley Graham jennifer@rpcgc.com Cliff Duch sgraham@coab.us cliff@arch-cd.com Jennifer Walker Engineer: jwalker@coab.us Wayne D.Mangum, P.E. wmangum@mcveighmangum.com STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING • BIM 9133 R.G.Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLANTA,GA • CHARLOTTE,NC • JACKSONVILLE,FL '-i Y � fik b Z h `a <. a RMx y ' N � M� r r liw z� It u� Q <r W,