201 NAUTICAL BLVD ACRS17-0213 HVAC PERM MECHANICAL RESIDENTIAL HVAC PERMIT NUMBER
ACRS17-0213
PERMIT
ISSUED: 3/25/2019
CITY OF ATLANTIC BEACH EXPIRES: 9/21/2019
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
201 NAUTICAL BLVD MECHANICAL RESIDENTIAL REPLACEMENT HVAC $0.00
HVAC
I
TYPE OF REALESTATE BUILDING USE
ZONING: SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
1707030386 SEASPRAY
COMPANY: ADDRESS: CITY: STATE�
SNYDER HEATING &AIR P 0 BOX 16826 JACKSONVILLE FL 32245
OWNER: ADDRESS: CITY: !___STATE: ZIP:
WARDREP CHRISLEY P 201 NAUTICAL BLVD S ATLANTIC BEACH FL 32233-4120
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
AC AND REFRIGERATION 455-0000-322-1000 2 $16.00
FURNACES AND HEATING 4SS-0000-322-1000 24000 $24.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $SS.00
STATE DBPR SURCHARGE 455-0000-208-0600 0 $2.00
STATE DCA SURCHARGE 4S500002080700 0 $2.00
TOTAL: $99.00
Issued Date:3/25/2019 1 of 2
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax (904) 247-5845
JOB ADDRESS: -Z41 ed a/"j 5 PERMIT#-k�Z�0- 02A3
PROJECT VALUE $ 5-& ARI# '6 5'�1 REQUIRED
Air Handling Equipment Only
_X_Air Handling Unit & Condenser Condenser Onlv
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit
Heat: Unit Quantity I BTU's Per Unit Seer Rating ko
Duct Systems: Total CFM kE—Q tJIR ED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers ffU's
Elevators/Escalators
4,LL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
lermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
his application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
iot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name luo-;j k"fa PhoneNui�iber V(P-7991S
Vechanical Company Office Phone &YI-0600 Fax (Pql-=q
:�o. Address: City State AC Zip 57-Z4
License Holder(Print): MAW)^ S C ification/Registration# 14z4&11�13309-
Votarized Signature of License Holder 4
HOLLY A.FOUST yv
MY COMMISSION#FF NM Before me this day of— 20
WIRES:Ju�21,2= lzz�L� 0,
Bw4WTrnBW*N&ryS0*K Signature of Notary Public U
"lop This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
AMU so ILI CERTIFIE between Feb 17, 2009 and Dec 31, 2016.
wwtv,ahridirectory,!�r J
Certificate of Product Ratings
AHRI Certified Reference Number: 8331332 Date: 11/1/2017
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: DZ16SA0241B*
Indoor Unit Model Number: ASPT29B14A*
Manufacturer: DAIKIN MANUFACTURING COMPANY, L.P.
Trade/Brand name: DAIKIN
Series name: DZ16SA
Manufacturer responsible for the rating of this system combination is DAIKIN MANUFACTURING COMPANY,
L.P.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity (Btuh): 24000
EER Rating (Cooling): 13.00
SEER Rating (Cooling): 16.00
Heating Capacity(Btuh) @ 47 F: 24000
Region IV HSPF Rating (Heating): 9.00
Heating Capacity(Btuh) @ 17 F: 14500
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all ilability for damages of any kind arising out of the use or performance of the product(s).or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the
directory at www.ahrld I rectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.Thi Certificate shall only be used for individual,personal and psi
5 A 1 2-111
confidential reference purposes.The contents ofthis Certificate may not.in whole orin part,be reproduced;copied;disseminated; ru
entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING.HEATING.
personal and confidential reference. &REFRIGERATION INSTITUTE
CERTIFICATE VERIFICATION
he information forthe model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link wcmake h6e better"
T ued
and enter the AHRI Certified Reference Number and the date on which the certificate was iss
which is listed above,and the Certificate No.,which is listed at bottom right. CERTIFICATE NO.: 131540242184265438
@2014 Air-Conditioning,Heating,and Refrigeration institute
Cash Register Receipt Receipt Number
V
F441 City of Atlantic Beach R8531
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $198.00
ACRS17-0213 Address: 201 NAUTICAL BLVD APN: 170703 0386 $99.00
MECHANICAL $95.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
AC AND REFRIGERATION 455-0000-322-1000 2 $16.00
FURNACES AND HEATING 455-0000-322-1000 24000 $24.00
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0600 $2.00
STATE DCA SURCHARGE 45500002080700 0 $2.00
ACRS18-0464 Address: 1441 BEGONIA ST APN: 171082 0500 $99.00
MECHANICAL $95.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
AC AND REFRIGERATION 455-0000-322-1000 2 $16.00
FURNACES AND HEATING 455-0000-322-1000 24000 $24.00
STATESURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R8531 $198.00
Date Paid: Monday, March 25, 2019
Paid By: SNYDER HEATING & AIR
Cashier: CB
Pay Method: CREDIT CARD 805274
Printed: Monday, March 25, 2019 9:48 AM 1 of I