705 Atlantic Blvd MCAC19-0006 HVAC permit MECHANICAL COMMERCIAL HVAC PERMIT NUMBER DETAILS PER BUILDING PLANS MCAC19-0006 ISSUED: 4/9/2019 PERMIT EXPIRES: 10/6/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: MECHANICAL COMMERCIAL install 4-ton 48K-BTU AHU & 705 ATLANTIC BLVD HVAC DETAILS PER BUILDING 1.61<-cfm duct system $7185.00 PLANS TYPE OF REALESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 1706550000 SALTAIR SEC 01 COMPANY: ADDRESS: CITY: STATE: ZIP: FLORIDA AIR SERVICE & 150 HILDEN ROAD, #308 PONTEVEDRA FIL 32081 ENGINEERING OWNER: ADDRESS: CITY: STATE: ZIP: SEMINOLE SOUTH, LLC 2300 MARSH POINT RD, 301 NEPTUNE BEACH FIL 32266 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT AC AND REFRIGERATION 455-0000-322-1000 4 $32.00 AIR DUCT SYSTEM 455-0000-322-1000 1600 $20.00 FURNACES AND HEATING 455-0000-322-1000 48000 $24.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 Issued Date:4/9/2019 1 of 2 MECHANICAL COMMERCIAL HVAC PERMIT NUMBER MCAC19-0006 DETAILS PER BUILDING PLANS ISSUED: 4/9/2019 PERMIT EXPIRES: 10/6/2019 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL:$135.00 Issued Date:4/9/2019 2 of 2 "ALL INFORMATION Mechanical Permit Application HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY 15 REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 i"aAc 19 -00CD,6 Phone: (904) 247-5826 Email: Build ing-Dept@coab.us P E R M IT#: comm 19-0002 JOB ADDRESS: 705 atlantic blvd PROJECT VALUE $7.185.00 FV_1 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED) 9162789 El Air Handling Equipment Only El Condenser Only El Air Handling Unit& Condenser Air Conditioning: Unit Quantity 1 Tons per Unit 4-0 Heat: Unit Quantity 1 BTU5 per Unit 4 Seer Rating (REQUIRED) 14.00 Duct Systems: Total CFM 1,600 F-1 REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED) []Air Handling Equipment Only 0 Condenser Only E]Air Handling Unit& Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating (REQUIRED) Duct Systems: Total CFM FIFIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) F_]FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace (Qty) Automobile Lifts Gas Piping Outlets Boilers BTUs Elevators/Escalators [—]ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTUs Water Heaters Solar Collection Systems Tanks (gallons) Wells [-']OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Name: Seminole South LLC Phone Number: Mechanical Company: Florida Air SErvice&Engineering Office Phone: (904)823-9696 Fax(904)823-9995 Co.Address: 150 Hilden Road#308 City: Ponte Vedra State: fl Zip: 32081 License Holder: John H Sasser State Certification/Registration# CAC051467 Notarized Signature of License Holder ent was acknow 20 The foregoin i t ledged before me this.—day County of �Si�gnre of Notary Pu uI 1/1) p Personally Known OR I I Pro�ucecl linti/ficat'd Type of Identification: Updated 1019118 Cash Register Receipt Receipt Number W City of Atlantic Beach R8693 DESCRIPTION ACCOUNT CITY PAID PermitTRAK $135.00 MCAC19-0006 Address: 705 ATLANTIC BLVD APN: 170655 0000 $135.00 MECHANICAL $131.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 AC AND REFRIGERATION 455-0000-322-1000 4 $32.00 AIR DUCT SYSTEM 455-0000-322-1000 1600 $20.00 FURNACES AND HEATING 455-0000-322-1000 48000 $24.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R8693 $135.00 Date Paid:Tuesday, April 09, 2019 Paid By: FLORIDA AIR SERVICE & ENGINEERING Cashier: CT Pay Method: CREDIT CARD 040602 Printed:Tuesday,April 09,2019 9:06 AM 1 of 1