230 10th Street ROW19-0011 Pole Install RIGHT OF WAY PERMIT PERMIT NUMBER
CITY OF ATLANTIC BEACH ROW19-0011
800 SEMINOLE ROAD ISSUED:4/12/2019
ATLANTIC BEACH. FL 32233 EXPIRES: 7/11/2019
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPIVIC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county,and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
• • . r . . . • OF • •
23010TH ST RIGHT OF WAY SINGLE OR TWO install 35-ft. pole for new $0.00
FAMILY RIGHT OF WAY home
TYPE OF REALESTATE BUILDING USE ZONING:
SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
170357 0000 ATLANTIC BEACH
PARKWAY
COMPANY: ADDRESS:
Jacksonville Electric 21 W. Church Street Jackonville FL 32202
Authority
• ADDRESS:
FRANCIS JAMES D 23010TH ST ATLANTIC BEACH FL 32233-5750
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list. Container cannot be placed on City right-of-way.
1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
2 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL
Notes:
See attached Utility Map.
Issued Date:4/12/2019 1 of 2
RIGHT OF WAY PERMIT PERMIT NUMBER
>�� t
CITY OF ATLANTIC BEACH ROW19-0011
800 SEMINOLE ROAD ISSUED: 4/12/2019
ATLANTIC BEACH. FL 32233 EXPIRES: 7/11/2019
3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction. -
4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration,including sod,is required.
5 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
Issued Date:4/12/2019 2 of 2
City of Atlantic Beach APPLICATION NUMBER
Building Department j( % (To be assigned by the Building Department.)
BOB Seminole Road J APR 05 2010
II
Atlantic Beach,Florida 32233-644
Phone(904)247-6826 Fax(904) 5846
E-mail: building-dept@coab.us BY:___-__ Date routed:
-- City web-site: http:/twww.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: o�3� ( �- Sj Department review required Yes No
n Building
Applicant: E Planning B Zoning
'2 t�_. Tree Administrator
Project: '0 Sy_o o J S - 1 Pat-6f Pu
< Public Utilifies
Pubic
Fire Services
Review fee $ IWI Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified B
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: [Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING 8 ZONING Reviewed b : Date:
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. [-]Not applicable
Comments:
Reviewed by: Date:
Revised 05119/2017
City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
800 Seminole Road
:r Atlantic Beach, Florida 322335445
- II
Phone(904ding-d building
-5845
x;oa pP E-mail: buildingdeptQcoab.us Date routed:
City web-site: http Hwww.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: a 3� (� St Department review required Yes No
Building
Applicant: E Planning &Zoning
(r� [ Tree Administrator
Project: \n S�-c{lI 3S — 't'l pd��l Pu
nP w h aNL� Public Utilities
Pubic y
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLIC N STATUS
Reviewing Department First Review: pproved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING&ZONING �yy
Reviewed by:
TREE ADMIN. Second Review: []Approved as revis d. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 0919/2019
RIGHT-OF-WAY/EASEMENT PERMIT APPLICATION "ALL INFORMATION
City of Atlantic Beach HIGHLIGHTED IN GRAY IS
SM Seminole Road,Atlantic Beach,FL 32233 REQUIRED.
PERMITTEE RESPONSIBLE FOR NOTIFYING$11 AND OBTAINING UTILITY LOCATES
lob Address J1
0" /0? r'CePermit Number F—C'� le? (Mill
Contractor lnformaattioIn APR - 1 2019
Company JE - Qualifying Agent
Address-7,1 Ve6t- �UfO'Ls .5�. City 7-,4X state_,^L2ip 32LUZ
Phone - Email
State Certification/Registration M
Architect Phone Email
Engineer JZSirm IQ<rr91vt Phone 665-?713 Email .S�� JI&A. ror
Workers Compensation Insurerl+ I OR Exemptr]Expiration Date
• Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial
and underground and the accurate locations are shown on the sketches.
• Whenever necessary for the construction,repair,Improvement,maintenance,safe and efficient operation,alteration or
relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles,
wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be Immediately removed from said
street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the
Permittee unless reimbursement is authorized.
• Allwork shall meet MY Atlantic Beach or Florida Department of Transportation Standards and be performed under the
supervision of K "I. a„0.49a'a (Project Superintendent)
with(Company Name) T- •,� Phone 66S-- rfya
• All materials and equipment shall be subject to Inspection by the Public Works Director.
• All city property shall be restored to Its original condition as far as practical,in keeping with City spacifiations and the
manner satisfactory to the City.
• A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit.
Calculations showing any increase in impervious area on owners lot or in the City right-of-way are to be included with
this application.
• The permittee shall commence actual construction in good faith within_days. If the beginning date is more than Go
days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no
changes have occurred In the area that would affect the permitted construction.
• It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,
title and Interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of
and Indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of
expenses arising In any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges.
• Th I' o y—y-11``fEc--�or/s/hal�l be notified 24 hours prior to starting work and again immediately upon completion.
V�..�al� Date '&!—Ld
Permittee(signed In presence of Plotirry Public)
STATE OF FLORIDA,COUNTY OF DUVAL
The foregoing instrument was acknowledged this day of 20
by who personally appeared before me and
(printed name of Permmee)
acknowledged that he/she signed the Instrument voluntarily for the purpose expressed In It.
I I Personally Known
Signature of Notary Public,State of Florida I [ I Produced Identification(Type)
HAApp9catiens&forms\Ward Documenbt101801001 RightroRWay Easement Permit Appacatbn.doex Revision Date:10/1/19
ENGINEERING DESIGN
ORACLE PERMIT MAXIMO DATE REL
PROJECTS:38048 N.O.: 8005212 WO#: 30415083 CONST 04MItig
CIR. TREE TRIMMING
SUBSTA: NEPTUNE BEACH N.0.:583 REO'D:NO
CELL
ENGINEER:Robert Simesee N.O.: NIA ZIP CODE:WA
CU$TOMERI SVC PHONE
LOCATION:22810TH STJ 3514 POLE INSTALL 563 CENTER:SSSC N.O.:665.7n3
O iJI
0 o N
STA 1, P# 228 10TH ST../ INSTALL o •
3614W RUN 410P TO STA 2. p C7
8 y 178
STA 2, P#22710TH ST. Z
Y p
'••" NEW HOME BUILD'•" •
c 0 • 1057 ti
p♦ " r "a • �` N 1 ♦ ♦ �
0
Y o I � v, C • �Oj.
o• STA2 0 .0
00 j
303 50C i •N o • o I 1005
4 i ^ ^ ma I OT
NI I 4
2 1002 N N 10TH ST i- _ _
25T 1 _ �-�----------- - C 1 0
N 2/OP '-----_ _ _ 00 4/0
------------
B STA 1
ID
00 I 2T ♦ V I /r
4230
280
-46
4 D 937
303 • 505 10 /
Y � N• �
,o• ! i
PUBLIC UTILITIES PLAN REVIEW COMMENTS
Dat Iq' 119 _ Application ft:
Project Address: 23b to
Check Box Check
APPLICATION TRACKING COMMENTS to Add Box to
Comment Print
Underground Avoid damage to underground water and sewer utilities. Verify vertical and
Water Sewer horizontal location of utilities. Hand dig if necessary. If field coordination is
Utilities needed,call 247-5878.
Meter Bores Ensure all meter boxes,sewer cleanouts and valve covers are set to grade
Sewer Cleanout and visible.
A sewer cleanout must be Installed at the property line. Cleanout must be
RTS Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade
Cleanout I and visible.
A reduced pressure zone backflow preventer must be installed if irrigation will
RPZ be provided or If there is a private well on the property. Backflow preventer ❑ ❑
Backflow must be tested by a certified tester and a copy of the results sent to Public
Utilities.
Plans note the building will be unsprinkled. If plans change,any fire line
Sensus Installed must be metered with a Sensus touch-read meter In a properly sized
Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer ❑ ❑
Meter must be tested by a certified tester and a copy of the results sent to Public
Utilities.
Fire Sprinkler If fire sprinkler system is provided,call 247-5878 for backflow requirements.
Requirement At a minimum,will require a double check backflow preventer. [3 ❑
Fire Une Fire lines must be metered with a Sensus touch-read meter. Meters larger ❑ ❑
Meter than 2"must be Installed in a vault as noted In JEA specifications.
Utility Map See attached Utility Map.
Disconnect
&Cap Disconnect and cap water and sewer lines. ❑ ❑
Inspection Must call the inspection Line at 247-5814 to request an inspection of the
Prior disconnected and capped water and sewer lines prior to demolition. 13 ❑
❑ ❑
❑ ❑
❑ ❑
❑ Cl
9
1�rr
lip _ _ • • _
CEM
�1
1 .
1 1
w f
Iv �
t
i
ENGINEERING DESIGN
ORACLE PERMIT MAXIMO DATE REL
PROJECTM:38046 NO.: 8005212 WO M: 30415093 CONST:04101119
CIR. TREE TRIMMING
SUB-STA: NEPTUNE BEACH N.0.: 563 REVD:NO
CELL
ENGINEER:Robert Simpson N.O.: NIA ZIP CODE NIA
CUSTOMER/ SVC PHONE
LOCATION: 22810TH ST.13514 POLE INSTALL 563 CENTER:SSSC N.C.:665.7703
STA 1, P# 228 10TH ST../ INSTALL o
n N
3514W RUN 4/0P TO STA 2.
8 178
STA 2, P#227 10TH ST. )>
Y p
*`* NEW HOME BUILD "***
c 0 ♦ 1057'b
O♦ a 1d ♦ N -OI A 4 50C 0
O �
r
0 . r
N , C ♦� 1
Y o r � �n p ♦ �0�,
o• j STA2
00 1036
303 SOC i ♦N o ♦ o r 1005
N L r 4
T2 1002 N 10TH $T i
W 25T r ----------- - -'C 1 0
Ln 2/ 4/01
,>
- - - -
B- STA1
J
IV
I � ♦ / P V
00 ♦ I 2T ' N o
1 230 /
280
9
• j ♦U SSC
° 937
30350B ,p
,� r r
RIGHT-OF-WAY/EASEMENT PERMIT APPLICATION "ALL INFORMATION
City of Atlantic Beach HIGHLIGHTED IN GRAY Is
800 Seminole Road,Atlantic Beach,FL 32233 REQUIRED.
n PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES_.-_—
Job Address 030 1 Q n 51 r,-,e Permit Numb -
�i l l
Contractor lydormattio.n APA
Company V E#— `l '' qualifying Agent _ -- ---�
Address Z{ 4 04
/e6P- woG , S0 City E4X State_Q__Zip 32LC1 -
Phone - Email
State CertlQcatlon/Registration if
Architect /� Phone Email
Engineer - J r�amlo<r9v _Phone 66E-2293 Email "a CG.
Workers Compensation Insurer - OR ExemptoExpiration Date
• Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial
and underground and the accurate locations are shown on the sketches.
• Whenever necessary for the construction,repair,Improvement,maintenance,safe and efficient operation,alteration or
relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles,
wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said
street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the
Permittee unless reimbursement is authorized.
• All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the
supervision of k 1 (Project Superintendent)
with(Company Name) Phone rebs-- 22e3
• All materials and equipment shall be subject to inspection by the Public Works Director.
• All city property shall be rest oredto its original condition as far as practical,in keeping with City specifications and the
mariner satisfactory to the City.'
• Asketch of plans covering details ofmis installation,as well.as a copy of a recent survey shall be made a part of this permit.
Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with
this application.
• The permittee shall commence actual construction in good faith within_days. If the beginning date is more than 60
days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no
changes have occurred in the area that would affect the permitted construction.
• It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the Drys right,
title and Interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of
and Indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of
expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. .
• Th I' or �c or shall be notified 24 hours prior to starting work and again Immediatelyy�upon completion.
�
Permittee(signed In presence of otary Public)
STATE OF FLORIDA,COUNTY OF DUVAL
The foregoing instrument was acknowledged this day of 20
by who personally appeared before me and
(printed name of Permittee) -
acknowledged that he/she signed the Instrument voluntarily for the purpose expressed in it.
I )Personally Known
Signature of Notary Public,State of Florida I I )Produced Identification(Type) I
r0\Appliations&Farms\WnM Do umena\201801001 Rightnf.Way Eaument Puma Applicadon.docx Revhlon nam:10/1/18
.AGA. CUE Reports
EstimaW Number:38046 23010TH ST I POI,INSTALL Estimate Type:SR Contract 089-16HM OH FY19
Estimate Version: By: SIMPRB
MWOWask:30415093 Required Date:
Orerle Project M:8006212 Estimated On: 03/29/2019
Cost Estimate
M.W,wl. JEA Conkubr
I-New Materiel Coal(W/Soles tan) $398.64 $398.84
2.T2esbrmer Cost(w/sales tax) $0.00 $9.00
3.Returned Material Salvage Value $0.00 $0.00
Labor
4.Crew Time $499.02
5.E ndk ary Costs $0.00 $0.50
JEA Overhead
6.Fringe Benefits(Q.62%of Was 4 81) $2A.88 $121.59
].Engineering Costs(VarlaNe%of line 4) $139.48 $279.40
B.Project Equipment Casts(40%of WWI equipment costs) $291.67 $0.00
9.Material Handling(6.67%of lines 1 8 2) $26.59 $2859
10.Inspection(6.84%of line 4) $0.00 $11431
11.TOWI Cost of Project $1,633.27 $1,614.91
12.Work Order allmaW(Line 11 minus line 8,9,810) $1,315.01 $2,588.32
13.Mobile Equipment DWecialion(60%of WWI equipment costs) $437.511 $0.00
14.Billing Estimate(Including Translonner Coat)(Lines 11+13+(84.49%of 4$])) $2,482.54 $2,795.10
15.Billing E.Wn.W(W/O Transformer Cost)(Lines 11+13+("Aale of 467)-Line 2) $2,462.54 $2]95.10
Time Estimate
Crew Hours Tarot MenMurs
4.00 16.00
'W CUE Reports
EaBmete Number:36046 23010TH STIPOLE INSTRLL Estimate Type:SR Contract:O89-16-HM OH FY19
Estimate Version: By: SIMPRB
MWOH ask:3041M93 Required Date:
Oracle Pmjea 9:8005212 Eetlres d On: 03/292019
CU Detail
Station: C 1 228 JOTH ST,
Build TrsnwMr RemaM MPlaw Remove
C2/0P 50
G3W2 1
GY3"5 1
P.3514W 1
54'4/0 i
0
Build Transrer Remeln In Pleea Remora
RUBUP 2
S20ES'2/0-2/0 1
84'2/0 1
S9'2 2
S9'210 2
SEVP 1
RUBDOWN 2
JVI CUE Reports
Estimate Number:38848 23818TH STI POLE INSTALL Estimate Type:SR Conlr c-WI&HMOHFy19
Estimate Version: By: SIMPRB
MWOtl?ask:38415893 Required Oats:
Oracle Pjo k:8885212 Estimated On: 03129/2019
Conductor, Conduit and Pipe Detail
Quantities
From Station To Station CLI Bulla Transbr Runein Remove
01 02 C.2/0P 50 0 0 0
.E1 CUE Reports
aftafe Number:38048 23010TH S POLE INSTALL Edimele Type:SR Centrad:0894&141e!OH FY19
aft.le,Vemlon: By. SIMPRB
MWO#Task:30415093 Requbed Oek:
Omcle Pmjed#:8005212 Esfimated On: 03129/2019
Material Summary
Omn Qwntky Mm Number Item Qesminlion
1 ANGSS002 ANCHOR,SCREW,SINGLE-HELIX,GALVANIZED 10"X&X 1-1/4",SHIP
ON OPEN FLATBED ONLY!
1 BOLMS036 BOLT,MACHINE,314"X 14",SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
50 CA10SO02 CABLE,2/0(PAP),OVERHEAD SERVICE DROP,600 VOLT MULTIPLEX
CABLE"MESA VERDE'PRE-ASSEMBLED PARALLEL SOUTHWIRE 61-
28-96-1, 1500 FOOT REELS
1 CLAGRO01 CLAMP,GROUND ROD,5/8"-4SOL"HAMMERLOCK'
1 CLASR002 CLAMP,STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP
1 CLASS004 CLAMP,STRAIGHT STRAIN,ALUMINUM,5000#,4-3/0 ALUM
I CLASS006 CLAMP,STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM(STD
PKG 15 EA)
7 CNNCP002 CONNECTOR,#2.6-2 MAIN,2-1/0 TAP,ALUMINUM COMPRESSION,
PARALLEL TAP,
7 CNNCP004 CONNECTOR,#4, 1/0-2/O MAIN,1/0-3/O TAP COMPRESSION,
PARALLEL TAP,ALUMINUM,
2 CNNVG003 CONNECTOR,6-2 SOU10-2 SOL,VISE GRIP PARALLEL, BRONZE
16 COBC0028 CONDUCTOR,#4 SOLID,SOFT DRAWN,BARE COPPER, 200',250,ON
PLASTIC REEL,4'X 11.5"W/2"HOLE
70 COBCW014 CONDUCTOR,#4,TYPE 40 DSA,COPPERWELD&COPPERWELD-
COPPER.204" DIAMETER 1480#BREAKING STRENGTH(50#COIL-
427')
10 COVIC002 COVER "D"DIE, INSULATING,2-12"
1 GUAGWO01 GUARD,GROUND WIRE,112"X i/2'X 96",GRAY PLASTIC
1 GUAGWO02 GUARD,"YELLOW", GUY WIRE, 1/4"TO 112"8',POLYETHYLENE,USED
ON ALL 3/8"AND 7116"GUY STRANDS(DISTRIBUTION)
1 GUYAT008 GUY HOOK, COMBINATION,MALLEABLE OR DUCTILE IRON, HOT DIP
GALV.13/16'MOUNTING HOLE,20,000 LB MIN.ULT.STRENGTH.FOR
WOOD OR CONCRETE POLES
2 GUYGRO01 GRIP,GUY,3/8",26'p,GALVANIZED .
50 GUYST005 STRAND, GUY,3/8'DIA,7 PER STRAND,GALVANIZED STEEL, CLASS
"B"GALV.OR BEZINOL IS ACCEPTABLE (500'COIL)
1 INSGB002 INSULATOR,STRAIN, GUY BREAKER,21,000#RATED,60"ROD
LENGTH, FIBERGLASS FOR USE ON JENS DISTRIBUTION SYSTEM
ONLY
2 INSS0002 INSULATOR,SUSPENSION,4',CLASS 52-9 NEMASTRENGTH 10000#,
GALV.FITTINGS
1 POLW0003 POLE WOOD 35'CLASS 4(TIL=44) WEIGHT=1,026 LBS
1 RODGRO03 ROD,GROUND,THREADLESS, 5/8"X 8',SHIP ON OPEN FLATBED
ONLYI
2 SLEAL002 SLEEVE,ORANGE TO ORANGE NEUTRAL 4-4 ALUMINUM TRIPLEX
NEUTRAL SPLICING
2 SLEFT004 SLEEVE,2/0,FULL-TENSION ALUMINUM COMPRESSION TYPE
1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK
CHARACTERS((NOT FOR-SLIDE IN"CHARACTERS)). 19.5"HIGH X 2"
WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG.
CUE Reports
Estimate Number.30048 23010TH STJ POLE INSTALL Ftlmate Type:SR Can"&089-1&HM OH F(19
Estimate Vembn: By: SIMPRS
MWON/rask:30415093 Req dmd 0ete:
Omde Project Y:8005212 Esllre. tl On: 03/29/2019
OF 50 EACH)
1 WASRDD05 WASHER,ROUND,3/4"BOLT SIZE X 2"DIAMETER, GALVANIZED,•`•
500 EACH PER BOX...
1 WASSF003 WASHER,SQUARE FLAT, 3"SQ X 114',518'X 3/4'BOLT SIZE,
GALVANIZED
1 WASSP002 WASHER,SPRING,3/4'BOLT SIZE,DOUBLE COIL HELICAL TYPE,
GALVANIZED(EXTRA HEAVY DUTY)
`rA CUE Reports
Estimate Numbm:38048 23010TH STI POLE INSTALL Estimate Type:SR Contract:089-16HM OH FYI9
Esfintb Vemlon: By: SIMPRB
MWO#/reAAN15093 Requlred Oate:
Omcle Pmlect#:8005212 Estimated On: 03129/2019
CU Summary
• Wntlh
C.210P 50 2/0 AAC PAP W/2/0 AMC NEUTRAL
G3W'2 1 WOOD POLE-NON-EQUIPMENT GROUND
GY3'5 1 GY3.530 DOWNGUY W/8 FT SCREW ANCHOR
P.35/4W 1 35 FT.CLASS 4 WOOD POLE
RUBUP 2 LINE RUBBER INSTALLATION, PER SECT.
S20ES"2/0-210 1 SECONDARY CONNECTION AT POLE
S4'2/0 1 SECONDARY DEADEND
Sr4/0 1 SECONDARYDEADEND
S9'2 2 SECONDARY SPLICE
S9K/0 2 SECONDARY SPLICE
SEVP 1 SEVERE COND. FOR POLE SETTING CREW
CU M., 9ueetde QsaFOalbn
RUBDOWN 2 LINE RUBBER REMOVAL,PER SECT.
JVI CUE Reports
Estimate Number:38046 23010TH STJ POLE INSTALL Estimate Type:SR Canned:099-16-HM OH Mg
Estimate Version: By: SIMPRB
MWOkRask:30 I!X)93 Required Data:
Onfle P.JW#:8005212 Estimatetl On: 03129/21119
CU Detail
BYIb transfer Raman m Place Remove
C.2/OP 50
G3W 2 1
GY3.5 1
P.35/4W 1
94.4/0 1
BuiIE Transfer Remain in Place Remove
RUBUP 2
S20ES2/0-210 1
542/0 1
S92 2
59'2/0 2
SEVP 1
RUBDOWN 2
�il. CUE Reports
EMimab Number:38046 23010TH STJ POIX INSTALL Estimate Type:SR Contract:089-16-HM OH Pri9
Estimate Varsion: By. SIMPRB
MWONffask:30415093 Required Date:
Orade Project 8:8005212 Estimated On: 03129/2019
Cost Estimate
Materials JEA C.M.Ier
1.New Material Cost(w/sales tax) $398.64 $39864
2.Transbrmer Cost(w/sees tax) $000 $0.00
3.Returned!Material Salvage Value $0.00 $0.00
Labor
4.Crow Time $499.02 $1,674.16
5.Extraominary Costs $0.00 $000
JEA Overhead
6.Fringe Benefits(43.52%orf Imes 487) $277.66 $12159
7.Engineering Costs(Varlade%of line 4) $139.48 $279.40
S.Project Equipment Costs(40%of total equipment costs) $291.67 $0.00
9.Material Handling(6.67%of lines 1 8 2) $26.59 526.59
10.Inspection(6.84%of line 4) $0.00 $114.51
11.Total Cost of PmjW $1,83327 $2,614.91
12.Work Order Estimate(Line 11 minus line 8,9,810) $1,31501 52,588.32
13.Billable Equipment OeprenWhon(60%of btal equpmel cosh) $437.50 50.00
14,Billing Estimate(Including Transformer Cost)(Jnes 11+13+(64.49%orf 4 d 7)) $2.482.54 $2,795.10
15.Billing estimak(W/O Transformer Cog)(Lbes 11+13+(64.49%of 487)-Line 2) $2,482.54 $2,795.10
Time Estimate
Crew Haum TOW Mvnhows
400 16.00
JVT CUE Reports
Esdmate Number.38046 23010TH STJ POLE INSTALL Eslbnsle Type:SR C Vact NSA6-HMOH Fn9
Eslimale Version: By: SIMPRB
MWONTaA:3041 ON Required Oale:
Omd Proles[#:8005212 Estimated On: O3@9I2019
Material Summary
Item Manny Ilam Number Nam p .dplion
1 ANCSS002 ANCHOR,SCREW, SINGLE-HELIX,GALVANIZED 10'X 8'X 1-1/4', SHIP
ON OPEN FLATBED ONLY!
1 BOLMS036 BOLT,MACHINE,3/4"X 14', SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD.BOX -
QUANTITIES OF 25 EACH)
50 CAJOS002 CABLE,2/0(PAP),OVERHEAD SERVICE DROP,600 VOLT MULTIPLEX
CABLE"MESA VERDE"PRE-ASSEMBLED PARALLEL SOUTHWIRE 61-
28-96-1, 1500 FOOT REELS
1 CLAGR001 CLAMP,GROUND ROD, 5/8"-4SOL"HAMMERLOCK"
1 CLASR002 CLAMP,STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP
I CLASS004 CLAMP,STRAIGHT STRAIN,ALUMINUM,5000#,4-3/0 ALUM
1 CLASS006 CLAMP,STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM(STD
IRKS 15 EA)
7 CNNCP002 CONNECTOR,#2.6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION,
PARALLEL TAP,
7 CNNCP004 CONNECTOR,#4, i/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION,
PARALLEL TAP,ALUMINUM,
2 CNWG003 CONNECTOR,6-2 SOU10-2 SOL,VISE GRIP PARALLEL, BRONZE
16 COBC0028 CONDUCTOR,#4 SOLID,SOFT DRAWN, BARE COPPER, 200',25#,ON
PLASTIC REEL,4"X 11.5'W/2"HOLE
70 COBCW014 CONDUCTOR,#4,TYPE 40 OSA, COPPERWELD&COPPERWELD-
COPPER.204"DIAMETER 1480#BREAKING STRENGTH(50#COIL-
42r)
10 COVIC002 COVER,-D"DIE,INSULATING,2-12"
1 GUAGWO01 GUARD,GROUND WIRE, 1/2'X 1/2"X 96',GRAY PLASTIC
1 GUAGWO02 GUARD,"YELLOW", GUY WIRE, 1/4"TO 12"8',POLYETHYLENE, USED
ON ALL 3/8"AND 7/16"GUY STRANDS(DISTRIBUTION)
1 GUYATO08 GUY HOOK,COMBINATION, MALLEABLE OR DUCTILE IRON,HOT DIP
GALV. 13116'MOUNTING HOLE,20,000 LB MIN.ULT.STRENGTH. FOR
WOOD OR CONCRETE POLES
2 GUYGR001 GRIP,GUY, 3/8",26",GALVANIZED .
50 GUYST005 STRAND,GUY,3/8"DIA,7 PER STRAND,GALVANIZED STEEL,CLASS
"B"GALV. OR BEZINOL IS ACCEPTABLE (500'COIL)
1 INSGB002 INSULATOR, STRAIN, GUY BREAKER,21,000#RATED,60"ROD
LENGTH, FIBERGLASS FOR USE ON JENS DISTRIBUTION SYSTEM
ONLY
2 INSS0002 INSULATOR,SUSPENSION,4",CLASS 52-9 NEMA STRENGTH 10000#,
GALV.FITTINGS
1 POLW0003 POLE,WOOD 35-CLASS 4(TIL=44) WEIGHT=1,026 LBS
1 RODGRO03 ROD, GROUND,THREADLESS,5/8"X e',SHIP ON OPEN FLATBED
ONLYI
2 SLEAL002 SLEEVE,ORANGE TO ORANGE NEUTRAL 4-4 ALUMINUM TRIPLEX
NEUTRAL SPLICING
2 SLEFT004 SLEEVE,2/0,FULL-TENSION ALUMINUM COMPRESSION TYPE
1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK
CHARACTERS((NOT FOR'SLIDE IN'CHARACTERS)). 19.5'HIGH X 2"
WIDE WITH 3-1/8"NAIL HOLES Q THE TOP AND THE BOTTOM. (PKG.
JEACUE Reports
Estimate Number:38098 23010TH STI POLE INSTALL E.U.M Type:SR Conrad:089-16HMOHM9
Estmate Vemkm: By. SIMPRB
MWOp/rask:30015093 Required Dile:
Omde"aI#:8005!12 Estimated On: 0329/2019
Conductor, Conduit and Pipe Detail
Buanuies
Fmm Stalbn TOSUYon CO Build TnmNr Remain Reme
01 02 C.2/OP 50 0 0 0
`KA CUE Reports
Esdnr e e Number 39049 23010TH STJ POLE INSTALL Estimate Type:SR Contract 099-1SHM OH FY19
EsOmate Version: By: SIMMS
MWO#,Task:3041 W93 Required Dale:
Orade Project R:9005212 Estimated On: 0312912019
OF 50 EACH)
1 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X2'DIAMETER, GALVANIZED, ^'
500 EACH PER BOX"'
1 WASSF003 WASHER, SQUARE FLAT,3"SQ X 114". 518'X 3/4"BOLT SIZE,
GALVANIZED
1 WASSP002 WASHER,SPRING,3/4'BOLT SIZE,DOUBLE COIL HELICAL TYPE,
GALVANIZED(EXTRA HEAVY DUTY)
`{moi* CUE Reports
Estimate Number:38046 23010TH STJ POLE INSTALL EallmaW Type:SR Contract:089-16HM OH PY19
EaOmaM Va n: By: SIMPRB
MWO#Rea8:30415093 Pe uimd 09fe:
Oracle Project#:8005212 EatimaW On: 03129/2019
CU Summary
CU M. ➢Y w !
C.210P 50 210 AAC PAP W/2/0 AAAC NEUTRAL
G3W'2 1 - WOOD POLE-NON-EQUIPMENT GROUND
GY3'5 1 GY3'53/8" DOWNGUY W/O FT SCREW ANCHOR
P.3514W 1 35 FT.CLASS 4 WOOD POLE
RUBUP 2 LINE RUBBER INSTALLATION, PER SECT.
S20ES'2/0-210 1 SECONDARY CONNECTION AT POLE
S4'2/0 1 SECONDARY DEADEND
W410 1 SECONDARY DEADEND
S9.2 2 SECONDARY SPLICE
S9'2/0 2 SECONDARY SPLICE
SEVP 1 SEVERE COND. FOR POLE SETTING CREW
W. 9uamw Gnr U.
RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT.