Loading...
1705 Maritime Oak Dr ROW19-0013 Replace CableCITY PERMIT COVER D rev JA I SITE MAP I MOT NOTES TRAFFIC CONTROL SHALL COMPLY WITH FEDERAL MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND F.D.O.T. DESIGN STANDARD #NO. 600. COMCAST PROPRIETARY AND CONFIDENTIAL 5934 Richard St A—i— nviU FI 32216 CITY" OF ATLANTIC BEACH, FL RIGHT-OF-WAi PERMIT PROJECT TOTALS PROP. BURIED CATV: 222' PROP. OH CATV: 0' TOTAL PROP. CATV: 222' (0.42M1.) 1705 MARITIME OAK DR SUBJECT: COUNTY: DUVAL PROPOSED U/G CATV STATE: FLORIDA FACILITIES ON MARITIME OAK DR. SHEET NO.: 1 OF 5 DATE: 03/14/2019 CIFA: MAP: N/A DRAFTED BY: M. VERGARA F-1 1705 MARITIME OAK DR CITY PERMIT NOTES & TYPICALS CITY OF ATLANTIC BEACH 1J/G NOTES ALL PROPOSED CONSTRUCTION WILL BE PER CITY OF ATLANTIC BEACH SPECIFICATIONS AS WELL AS ALL NESC SAFETY CODES. ------------- SWALE/DITCH JOINT USE TRANSFORMER POLE ALL PROPOSED CAN WILL BE WITHIN THE CITY OF ATLANTIC BEACH RIGHT-OF-WAY. CAN POLE PROPOSED OVERHEAD CAN ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 24" DEEP. EXCEPT BORES 36" DEEP. NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION. II OVERHEAD GUY --- ---------- - GAS LOCATES WILL BE REQUIRED IN ALL PROPOSED ® TRAFFIC SIGNAL VAULT UNDERGROUND AREAS AT LEAST 48 HRS. PRIOR TO CONSTRUCTION. STORM SEWER a CROSS SECTION REFERENCE ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY. APPROVED DIRECTIONAL BORE MACHINE, AS , WELL AS CITY APPROVED CONDUIT. ALL PROPOSED CAN DIRECTIONAL BORES WILL EXTEND A MINIMUM OF 5' BEYOND THE EDGE OF PAVEN1'ENT. ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 2' BEYOND THE EDGE OF PAVEMENT. �1I COMCAST PROPRIETARY AND CONFIDENTIAL 5934 Richard St Jacksonville, FL 32216 ALL UTILITIES LOCATED BY VISUAL INSPECTION, TO VERIFIED BY LOCATES. EOT REPRESENTS EDGE OF TRAVEL NOT TRUE EDGE OF PAVEMENT. E/P REPRESENTS THE TRUE EDGE OF PAVEMENT. EOD REPRESENTS THE EDGE OF DIRT. HAND DIG TRENCHES 36" DEEP ACROSS DIRT ROAD. LEGEND X POWER POLE BORE POWER TRANSFORMER POLE ® ------------- SWALE/DITCH JOINT USE TRANSFORMER POLE GUARD RAIL Q PHONE POLE —o 0 0 ❑ o FENCE LINE CAN POLE PROPOSED OVERHEAD CAN QS STEEL POLE - - - - - - - PROPOSED BURIED CAN © CONCRETE POLE EXISTING OVERHEAD CAN ® JOINT USE POLE - - - - - - - EXISTING BURIED CATV ® RISER OVERHEAD ELECTRfC �Q ANCHOR -----•-------•-•--- BURIED ELECTRIC II OVERHEAD GUY --- ---------- - GAS OV CAN FIBER VAULT OVERHEAD TELEPHONE ® TRAFFIC SIGNAL VAULT BURIED TELEPHONE ® TRAFFIC SIGNAL POLE SANITARY SEWER ® TRAFFIC SIGNAL BOX STORM SEWER a CROSS SECTION REFERENCE -'-`-'-`-'-`-`-'- WATER ???'AERIAL FOOTAGE - - - - - - - CENTERLINE ???'U/G FOOTAGE EDGE OF PAVEMENT / REFERNCE POINT BACK OF CURB ® STORM DRAIN -- "-"-"— RIGHT OF WAY CITY U' --"F ATLANTIC BEACH, RIGHT-OF-WAYPlE11,%'oMI FL \, \,\,\ /P 2' 2' PROPOSED 2" HDPE CONDUIT TYPICAL DRIVEWAY DIRECTIONAL BORE N.T.S. SUBJECT: PROPOSED U/G CAN FACILITIES ON MARITIME OAK CIFA:- 1705 MARITIME OAK DR COUNTY: DUVAL STATE: FLORIDA SHEET NO.: 2 OF 5 DATE: 03/14/2019 N/A BY: M. VERGARA 1705 MARITIME OAK � D R CITY PERMIT a • offset zone: i a. Behind an existing barrier, Worb. More than 2' behind the curb, k Area c. 15' or more from the edge of travel way. UD `1/A COMCAST PROPRIETARY AND CONFIDENTIAL 5934 Richard St Jacksonville, FL 32216 SYMBOLS ® Work Area Lane Identification + Direction of Traffic LAST 2 DESCRIPTION: O REVISION 11/01/17 _ GENERAL NOTES 1. If the work operation (excluding establishing and terminating the work areal requires that two or more work vehicles cross the offset zone in any one hour, traffic control will be in conformance with Index 102-602. 2. No special signing is required. 3. When a side road intersects the highway within the work area, additional TTC devices shall be placed in accordance with other applicable TCZ Indexes. 4. When construction activities encroach on a sidewalk refer to Index 102-660. 5. For general TCZ requirements and additional information, refer to Index 102-600. CONDITIONS WHERE ANY VEHICLE, EOUIPMENT, WORKERS AND THEIR ACTIVITIES ARE BEHIND AN EXISTING BARRIER, MORE THAN 2' BEHIND THE CURB, OR 15' OR MORE FROM THE EDGE OF TRAVEL WAY. F®OT FY 2019-20 TWO-LANE, TWO-WAY, WORK OUTSIDE S HOU LE R INDEX SHEET STANDARD PLANS102-601 1 of 1 SUBJECT: PROPOSE D U/G CATV CIT OF ATLANTIC BEACH' FL FACILITIES ON 8TH ST RIGHT-OF-WAYPERMITPEMIT CIFA: _ 05 MARITIME OAK DR COUNTY: DUVAL STATE: FLORIDA SHEET NO.: 3 OF 5 DATE: 03/14/2019 MAP: N/A DRAFTED BY: M. VERGARA Iwo 1705 MARITIME OAK DR CITY PERMIT PLAN VIEW 0 20' 40' X11 COMCAST PROPRIETARY AND CONFIDENTIAL 5934 Richard St Jacksonville, FL 32216 PROJECT START PROPOSED U/G CATV FACILITIES TIE INTO EXISTING CATV FACILITIES BOG 111- C-1727 Quo \� 06 ♦ s c3`- `� 0 G OG ♦ \� � � �`�pi'p 1 C� \ s e 0 � I I PROPOSED U/G CATV FACILITIES (pWATER METER ® 11 BOC PP. WATER METER 0 11 BOC 1 c0 PROJECT END PROPOSED U/G CAN FACILITIES TIE INTO EXISTING CATV FACILITIES / WATER METER 0 11'0()C ---E)(ISTING PED p 12' BOC IFIRE HIDRANT ® 6' BOC co % w�\W CITY OF ATLANTIC BEACH, FL RIGHT—OF—WAY PERMIT C-1699 1705 MARITIME OAK DR SUBJECT. COUNTY: DUVAL PROPOSED U/G CATV STATE: FLORIDA FACILITIES ON MARITIME OAK DR. SHEET NO.: 4 OF 5 DATE: 03/14/2019 CIFA:_ MAP: N/A DRAFTED BY: M. VERGARA