1545 Main St MECH19-0003 8 SprinklerLOPE LINE BELOW STAIR. HEAD UNDER STAIR LANDINIG. UP f A 1' UP SEE 1' UP SEE 1' UP SEE A-0j�2ND FLOOR 2ND FLOOR 2NF FLOOF � % FOR CONT. rIFOR CON`T. y�FOR CONT 4 AD A A AA OFFICE T CLG OFFICL 7' CLG F/w/u/111d!\ FLOOR FIRE PROTECTION P 7�v SCALE: Y4"=1' -O" RENOVATION 0 2' 4' 8' SCALE: %"=1 '-0" "0 EXISTING WAREHOUSE 1 N.I.C. ":f l 2ND FLOOR FIRE PROTECTION PLAN 17,V SCALE: 4"=1 ' -O" RENOVATION 0 2' 4' 8' SCALE: Y4"=1'-0" '—Z PURLIN r-%" HORIZONTAL MOUNT STEEL SCREW THREAD ROD FOR PIPE 1'-4" RING l'-4' -4" SIDEWINDER STEEL SCREW SCALE: NOT TO SCALE [�E _ BEAM CLAMP FOR 1"-4" PIPE FOR 6" PIPE ALL THREAD ROD -_ -" FOR 1"-4" PIPE FOR 6" PIPE f-tIANGER RING 1--6" IPE 1'-6" BEAM SCALE: NOT TO SCALE 1" x ARMOVER f-1 " 90' ELBOW 1" x NIPPLE ✓1" x DROP I" x 1�" REDUCING BRANCHLINE COUPLING FINISHED SPRINKLER HEAD CEILING RETURN BEND DETAIL SCALE: NOT TO SCALE KEY PLAN SCALE: NOT TO SCALE SCOPE OF WORK 1. ADD NEW SPRINKLER HEADS IN CONTRACT AREA WITH NEW QUICK RESPONSE SPRINKLER HEADS FROM EXISTING PIPING TO PROVIDE SPRINKLER COVERAGE IN EXISTING OFFICE AREA. 2. BUILDING IS FULLY SPRINKLED, USE EXISTING HYDRAULICALLY CALCULATED PIPE SCHEDULE FOR NEW HEADS. ABBREVIATIONS AFF ABOVE FINISH FLOOR A/S AUTOMATIC SPRINKLERS BFP BACKFFLOW PREVENTER CI CAST IRON CR CORROSION RESISTANT CV CONTROL VALVE DN DOWN DI DUCTILE IRON EC EXTENDED COVERAGE EL ELEVATION ELL ELBOW EH EXTRA H&ARD EOR ENGINEER OF RECORD EX EXISTING FF FINISHED FLOOR FM FACTORY MUTUAL FDC FIRE DEPARTMENT CONNECTION FHV FIRE HOSE VALVE FHVC FIRE HOSE VALVE CABINET FS FLOW SWITCH GPM GALLONS PER MINUTE HP HIGH PRESSURE LF LINEAR FEET LH LIGHT HAZARD LP LOW PRESSURE LPS LOW PRESSURE SWITCH MJ MECHANICAL JOINT NFPA NATIONAL PRE PROTECTION ASSOCIATION OH ORDINARY HAZARD OS&1' OUTSIDE SCREW & YOKE PS PRESSURE SWITCH PSI POUNDS PER SQUARE INCH QR QUICK RISPONSE REC PEND RECESSE7 PENDENT RN RISER NPPLE RPZ REDUCED PRESSURE BACKFLOW PREVENTER SQ FT SQUARE FEET TEMP TEMPERATJRE TS TAMPER SNITCH TYP TYPICAL UL UNDERWRITERS LABORATORY UNO UNLESS VOTED OTHERWISE W/ WITH SYMBOLS LEGEND t] SYMB SIZE is FLOW SWITCH Ts MAKE MODEL —MICROFAST OS&Y VALVE N CHECK VALVE TS p I BUTTERFLY jj}�^I,I{ij VALVE CHROME FIRE DEPARTMENT CONNECTION SII FIRE HOSE VALVE DALARM BELL A !RISER LOCATION Z NEW CONNECTION xx HYDRAULIC REFERENCE POINT UPRIGHT CAP { PLUG O FIRE HYDRANT QUICK RESPONSE, ADD NEW FIRE LINE zJ r - -- - - - EXISTING FIRE _INE SIDEWALL DEMOLISH EXIS'T-NG FIRE LINE MICROFAST SHADED AREA `TOT IN SCOPE 155-F OF WORK QUICK RESPONSE, ADD CEILING HEIGHT FIRE PROTECTION GENERAL IS40TES 1. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES, AND ALL GOVERNMENT REQUIREMENTS, 2. FINAL INSPECTION AND APPROVAL BY FIRE MARSHAL AND ARCHITECT/ENGINEER. 3. CUTTING 0- STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THIE WRITTEN APPROVAL OF THE ARCHITECT AND A FL REGISTERED STRUCTURAL ENGINEER. 4. PIPE ROUTNG SHOWN SHALL BE USED AND ANY ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN PROPER CLEARANCES SHALL BE PROVIDED. 5. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY. 6. METHODS CF HANGING AND SUPPORTING PIPING AND HEADERS SHALL BE IN ACCORDANCE WITH NFPA 13. 7. PROTECT ALL PENETRATIONS OF SMOKE/FIRE RATED WALLS, FLOORS, ETC. WITH AN APPROVED UL LISTED FIRESTOP SYSTEM. 8. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL DIFFUSERS, SPEAKERS, LIGHTING FIXTURES, AND CEILING SYSTEMS. 9. PROVIDE HEAD GUARDS ON SPRINKLER HEADS IN ELECTRIC, TELEPHONE, AND MECHANICAL EQUIPMENT ROOMS & OTHER LOCATIONS WHERE SPRINKLERS ARE SUBJECT TO DAMAGE. 10. AUTOMATIC SPRINKLER TEMPERATURE RATINGS TO BE IN ACCORDANCE WITH NFPA 13. 11. ALL COMPCNENTS SHALL BE LISTED BY UNDERWRITER'S LABORATORIES (UL) AND/OR APPROVED BY FACTORY MUTUAL (FM) FOR USE WITH FIRE PROTECTION SYSTEMS, I 12. ALL COMP(NENTS SHALL BE LISTED FOR THE MAXIMUM SYSTEM PRESSURE, 175 PSI MINIMUM. 13. ALL FIRE ALARM & DETECTION AND POWER WIRING SHALL BE ACCOMPLISHED UNDER T4 ELECTRICAL DIVISION. COORDINATE ALL FIRE ALARM, DETECTION, AND ELECTRICAL ITEMS WITH ELECTRICAL CONTRACTOR AND ENSURE PROPER INSTALLATION. 14. PROVIDE S'?RINKLERS ABOVE AND BELOW EXPOSED DUCTWORK OR OBSTRUCTIONS 4 FEFTI WIDE OR LARGER. 15. SPRINKLERS TO BE LOCATED IN THE CENTER -OF -TILE IN ALL AREAS WITH ACOUSTICAL CEILING TILES WHERE PRACTICAL. 16. NOT RESPONSIBLE FOR PROVIDING HEAT, HEATED ENCLOSURE(S), INSULATION, HEAT TRACING ETC. FOR ANY PORTION OF THE FIRE PROTECTION SYSTEM(S) UNLESS NOTED OTHERWISE. I 17. NOT RESPONSIBLE FOR PAINT PREPARATION, PAINTING ETC. FOR ANY PORTION OF THE FIRE PROTECTION SYSTEM(S). 18. NOT RESPONSIBLE FOR CUTTING OR PATCHING CEILING/SOFFITS ETC. APPLICABLE CODES FLORIDA FIRE PREVENTION CODE 5TH EDITION (2014) WITH THE LATEST REVISIONS. FLORIDA BUILDING CODE 5TH EDITION (2012) WITH THE LATEST REVISIONS, NFPA 13 (2010), STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS. NFPA 25 (2011), STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER-B&ED FIRE PROTECTION SYSTEMS. ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. I FIRE PROTECTION MATERIALS ABOVE GROUND PIPE & FITTINGS: 1" PIPING (THREADED): BLACK STEEL, SCHEDULE 40, ASTM A135 OIR A795 1" FITTINGS (THREADED): DUCTILE IRON, ASME/ANSI B16.3 K ' ' lilt E W E Lrj% �lcoksonviile Fire Prevention Div is,rft`II U j Orr10E COPY Approved By Permit Desk Building Department City of Atlantic Beach, FL OJ U EX�CEIONS P ION AS NOTEO S,IEET# SPRINKLER SYMBOL DESCRIPTION SYMB SIZE FINISH STYLE MAKE MODEL —MICROFAST PART # TEMP K—FACT NOTES TOTAL • �" CHROME PENDENT VIKING VK302 155'F 5.6 QUICK RESPONSE, ADD 3 z P�F-n— U) J BRASS UPRIGHT VIKING MICROFAST VK300 155'F 5.6 QUICK RESPONSE, ADD 2 zJ U CHROME SIDEWALL VIKING MICROFAST VK305 155-F 5.6 QUICK RESPONSE, ADD 3 O UPRIGHT Q EXISTING SPR'!,{LER � Q PENDENT U 0� EXISTING SPRINKLER SIDEWALL EXISTING SPRINKLER TOTAL SPRINKLERS: 8 911AI.NOE!FICE. 522 SI'OCIXTONSZTrREE7 9ACW9V VILLE, TL 32204 M -9m (904) 387-7973 TAX- (904) 394-7261 tiuE sz2tE: zNcr�u?WGq;Yn.0094 CjAIN�ESVILLrE OXWM- 2500 9V E. 18TtC`�R.`VR G.AIAT- S`UILLrE, I'L 32609 2MCO N E. (352) 380-0317 `FX (352) 378-1454 V) z 0 w w 0 0 z PROJECT FOLDER: FP -1 SHEET 01 OF 01 W U z CO � C' V) w o w Q 14, 2019 JOB NO: FP -226429 DRAWN BY: CHECKED BY: CO M z P�F-n— U) J F- M w LU LL ® ~ cn w z zJ U - 4z w � w "' 0 F -- O Q � Q U 0� ILL PROJECT FOLDER: FP -1 SHEET 01 OF 01 z o U CL w o � C' V) w o DATE: MARCH 14, 2019 JOB NO: FP -226429 DRAWN BY: CHECKED BY: RP DM PROJECT FOLDER: FP -1 SHEET 01 OF 01