1927 Beach Ave RES18-0010 RevisionJOB: 50224A JAMES AND SONS
LOC: LOT 52 N ATLANTIC BEACH
PLAN:TOVEY
DESIGNER: RICHARD TINGLEY
PITCH: VARIES
OVERHANG: 24"
FLOOR SYTEM: 16" SYS42
WIND CODE: 175 MPH EXPOSURE D CLOSED
ALL TRUSS PLATES ARE ALPINE PLATES
APPROVAL # 1999-3
ENGINEER OF RECORD
LUIS PONTIGO
496 OSCEOLAAVE
JACKSONVILLE, FL, 32250
904-242-0908
LICENSE NUMBER: 53311
ALL BEAMS ARE onCENTER LVL 2.0E BY BLUELINX
APPROVAL #FL15354
BM -1 4-1.75" X 16" LVL 34'
BM -2 2-1.75" X 16" LVL 6'
BM -3 2-1.75" X 16" LVL 14'
BM -5 2-1.75" X 9.5" LVL 8'
BM -6 2-1.75" X 16" LVL 11'
BM -8 2-1.75" X 16" LVL 16'
BM -9 2-1.75" X 16" LVL 5'
BM -10 2-1.75" X 16" LVL 14'
BM -11 2-1.75" X 16" LVL 3'
BM -12 2-1.75" X 16" LVL 13'
ENGINEER OF RECORD TO REVIEW
ALL BEAM AND TRUSS ENGINEERING
AND SIZE FOOTERS, HEADERS, COLUMNS AND
CAPS WHERE NECESSARY. TRUSS FABRICATOR
WILL NOT BE RESPONSIBLE FOR
REPAIRS RESULTING FROM ATRUSS OR
BEAM BEING INADEQUATELY SUPPORTED.
HANGERS ON JOB AREAS FOLLOWS
UNLESS NOTED OTHERWISE
APPLICATION PART # APPROVAL #
FLOOR TRUSS THA422 FL10447.22
2 -PLY BEAM HGUS412 FL11468.10
9-1-2 PLATE HEIGHT
11-1-2 PLATE HEIGHT
N M }
1
JOB: 50224D JAMES AND SONS
LOC: LOT 52 N ATLANTIC BEACH
PLAN: TOVEY REAR DECK REVISION
DESIGNER: RICHARD TINGLEY
PITCH: VARIES
OVERHANG: 24"
FLOOR SYTEM: 16" SYS42
WIND CODE: 175 MPH EXPOSURE D CLOSED
ALL TRUSS PLATES ARE ALPINE PLATES
APPROVAL # 1999-3
ENGINEER OF RECORD
LUIS PONTIGO
496 OSCEOLAAVE
JACKSONVILLE, FL, 32250
904-242-0908
LICENSE NUMBER: 53311
HANGERS ON JOB AREAS FOLLOWS
UNLESS NOTED OTHERWISE
APPLICATION PART # APPROVAL #
1-PLYTRUSS HTU26 FL10655.8
ENGINEER OF RECORD TO REVIEW
ALL BEAM AND TRUSS ENGINEERING
AND SIZE FOOTERS, HEADERS, COLUMNS AND
CAPS WHERE NECESSARY. TRUSS FABRICATOR
WILL NOT BE RESPONSIBLE FOR
REPAIRS RESULTING FROM ATRUSS OR
BEAM BEING INADEQUATELY SUPPORTED.
29-4-4 PLATE HEIGHT
30-0-14 PLATE HEIGHT30-9-10 PLATE HEIGWT
30-11-2 PLATE HEIGHT
31-0-14 PLATE HEIGHT
CJ89
JOB: 50224C JAMES AND SONS
CJ90
LUIS PONTIGO
CJ91
LOC: LOT 52 N ATLANTIC BEACH
JACKSONVILLE, FL, 32250
PLAN: TOVEY
y�8
LICENSE NUMBER: 53311
�
DESIGNER: RICHARD TINGLEY
„x
W
PITCH: VARIES
C19i
OVERHANG: 24"
m
N
FLOOR SYTEM: 16" SYS42
WIND CODE: 175 MPH EXPOSURE D CLOSED.
CJ89
mN�
EJ86
ALL TRUSS PLATES ARE ALPINE PLATES
o
APPROVAL # 1999-3
a�
CJ89
ENGINEER OF RECORD
CJ90
LUIS PONTIGO
CJ91
496 OSCEOLAAVE
JACKSONVILLE, FL, 32250
904-242-0908
y�8
LICENSE NUMBER: 53311
8
HANGERS ON JOB AREAS FOLLOWS
UNLESS NOTED OTHERWISE
APPLICATION PART # APPROVAL #
N 1-PLYTRUSS HTU26 FL10655.8
j 2 -PLY TRUSS HGUS262 FL10655.1
ENGINEER OF RECORD TO REVIEW
ALL BEAM AND TRUSS ENGINEERING
AND SIZE FOOTERS, HEADERS, COLUMNS AND
CAPS WHERE NECESSARY. TRUSS FABRICATOR
WILL NOT BE RESPONSIBLE FOR
REPAIRS RESULTING FROM ATRUSS OR
BEAM BEING INADEQUATELY SUPPORTED.
29-4-4 PLATE HEIGHT
30-0-14 PLATE HEIGHT
30-9-10 PLATE HEIGHT
30-11-2 PLATE HEIGHT
31-0-14 PLATE HEIGHT
ALL BEAMS ARE onCENTER LVL 2.0E BY BLUELINX
APPROVAL #FL15354
BM -19 3-1.75" X 9.25" LVL 14'
JOB: 50224B JAMES AND SONS
LOC: LOT 52 N ATLANTIC BEACH
PLAN:TOVEY
DESIGNER: RICHARD TINGLEY
HANGERS ON JOB AREAS FOLLOWS
UNLESS NOTED OTHERWISE
APPLICATION PART # APPROVAL #
PITCH: VARIES 1 -PLY TRUSS HTU26 FL10655.8
OVERHANG: 24" FLOOR TRUSS THA422 FL10447.6
FLOOR SYTEM: 16" SYS42 2 -PLY BEAM HGUS414 FL10531.3
WIND CODE: 175 MPH EXPOSURE D CLOSED
ALL TRUSS PLATES ARE ALPINE PLATES
APPROVAL # 1999-3
ENGINEER OF RECORD
LUIS PONTIGO
496 OSCEOLAAVE
JACKSONVILLE, FL, 32250
904-242-0908
LICENSE NUMBER: 53311
ENGINEER OF RECORD TO REVIEW
ALL BEAM AND TRUSS ENGINEERING
AND SIZE FOOTERS, HEADERS, COLUMNS AND
CAPS WHERE NECESSARY. TRUSS FABRICATOR
WILL NOT BE RESPONSIBLE FOR
REPAIRS RESULTING FROM ATRUSS OR
BEAM BEING INADEQUATELY SUPPORTED.
ALL BEAMS ARE onCENTER LVL 2.0E BY BLUELINX
APPROVAL #FL15354
BM -13 2-1.75" X 16" LVL 20'
BM -14 2-1.75" X 16" LVL 7'
06
BM -15 2-1.75" X 16" LVL 20'
BM -16 2-1.75" X 16" LVL 10'
BM -17 2-1.75" X 16" LVL 11'
N
BM -18 2-1.75" X 16" LVL 16'
20-7-0 PLATE HEIGHT
N
22-7-0 PLATE HEIGHT
O U