355 West 3rd Street ELEVATION 05.21.2019 U.S. DEPARTMENT OF HOMELAND SECURITY FE
National
errlember 30.2018
Federal Emergency Management Agency
National Flood Insurance Program
ELEVATION CERTIFICATE
important:Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for(1)community official, (2)insurance agent/company,and(3)building owner.
SECTION A-PROPERTY INFORMATION FOR INSURANCE COMPANY USE
Al. Building Owner's Name Policy Number:
GERALDINE BEASLEY ET AL,RONALD AND DONNA SUE BEASLEY
A2. Building Street Address(inciutling Apt.,Unit,Suite,arM/or Bldg.No.)or P.O.Route and Box Company NAIC Number
No.
355 WEST Sao STREET
City State ZAP
ATLANTIC BEACH FLORIDA 32233
A3.Property Deecdphon(Lot end Bock Numbers,Tax Parcel Number,Legal Description,etc.)
LOT 5 8 PART OF LOTS BLOCK 108 ATLANTIC BEACH SEC H; PLAT BOOK 18 PAGE 34;RE#170873-1000
A4.Building Use(e.g.,Residential,Na Residemial,Addifion,Accessory,etc.) RESIDEh A� —
A5. Lafitude/Longilude: LaL 30'19'38.85- Long.81'25' 19.58' Horizontal Datum: ❑ NAD 1927 ®NAD 1983
A6.Attach at least 2 photographs of the building 0 the Certificate is being used to obtain flood Insurance.
AT Building Diagram Number 1B
A8. For a building with a crawlspece or enclosure(s):
a) Square footage of crawlspace or enclosure(s) N/A sq fl.
b) Number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade N/A
c) Total net area of flood openings in A8.b N/A sq in.
d) Engineered flood openings? ❑Yes ® No
A9.For a building with an attachedgarage:
a) Square footage of attached garage 414 sq ff.
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 4
c) Total net area of flood openings in A9.b 300 sq in.
d) Engineered flood openings? ®Yes ® No
SECTION B—FLOOD INSURANCE RATE MAP(FIRM)INFORMATION
B1.NFIP Community Name 8 Community Number B2.County NameB3. tam
S
CITY OF ATLANTIC BEACH 120075 DUVAL FLORIDA
B4. Map/Panel 85. Suffix Bit.FIRM Index B7.FIRM Panel 88.Flood
89.Base Zone AD,use Base Fslood Depth)
Number Date Effective/ Zone(s)
Revised Date
12031CD408 J 1102018 11/2/2018 AE ELEV 6'
810.Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item B9:
❑ FIS Profile M FIRM ❑ Community Determined ❑ Other/Source:
611. Indicate elevation datum used for SFE in Item 89: ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source-
B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑Yes ®No
Designation Date: ❑ CBRS ❑ OPA
FEMA Form 08e-0-33(7/15) Replaces all previous editions. Page 1 of 7
OMB No. 1650-0008
EL'EVATI'ON CERTIFICATE Expiration Date:November 30,2018
IMPORTANT:In these spaces,copy the corresponding Information from Section A FOR INSURANCE COMPANY USE
Building Street Address(including Apt.,Unit,Suite,and/or Bldg. No.)or P.O. Route and Box No. Policy Number:
355 WEST 3m STREET
City State ZIPCode Company NAIC Number
ATLANTIC BEACH FLORIDA 32233
SECTION C-BUILDING ELEVATION INFORMATION(SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction` ® Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations-Zones Al-A30,AE,AH,A(with BFE),VE,V1-V30,V(with BFE),AR,ARIA,ARIAE,AR/A1-A30,AR/AH,AR/AO.
Complete Items C2.a_r below according to the building diagram specified in Item AT In Puerto Rico only,enter meters.
Benchmark Utilized: SEE COMMENTS Vertical Datum: NAVD 1986
Indicate elevation datum used for the elevations in items a)through h)below.
❑ NGVD 1929 0 NAVD 1988 ❑ Other/Sou":
Datum used for building elevations must be the same as that used for theBFE.
Check the measurement used.
a)Top of bottom floor(including basement,crewlspace,or enclosure floor) 8.73 0 feet ❑ meters
b)Top of the next higher floor — ❑feet ❑ meters
c)Bottom of the lowest horizontal structural member(V Zones only) �— 11 feet ❑ meters
d)Attached garage(top of slab) ------ 2feet El meters
e)Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment and location on Comments) 8.44 ®feet ❑ meters
f)Lowest adjacent(finished grade next to building(LAG) ---6.9— 0 feet ❑meters
g)Highest adjacent(finished)grade next to building(HAG) TZ_ 0 feet ❑ meters
h)Lowest adjacent grade at lowest elevation of deck or stairs, including NIA ❑ feet ❑ meters
structural support
SECTION D-SURVEYOR, ENGINEER OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor,an near,or architect authorized bylaw to certify elevation Information. 1
certify Mat the information on this Certificate represents my best efforts to interpret the data available. I understand that any false
statement may be punishable by Nre or imprisonment under 16 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? A Yes ❑ No ❑ Check here detachments.
Certifiers Nam License Number
JAMES D.HARRISON,JR. 2647
Title
REGISTERED LAND SURVEYOR place
Company Name
ALL AMERICAN SURVEYORS OF FLORIDA, INC. Seal
Address
3751 SAN JOSE PLACE,SUITE 15 //�].�^Je. �^"1
CRY Stale ZIP Code IJa
JACKSONVILLE FLORIDA 32257 S �(
Signatu Date Telephone Ext.
Jr 904279-0088
I gesofthis ationC teandellattachmen for )mmmunilyofficial,(2)insurance agendcompany,and(3)buildingowner.
Comments(including type of equipment and location,per 02(e),if applicable)
BENCHMARK:SET NAIL&DISK#38571N FRONT OF LOT 5&6 ELEVATION S.OT NAVD 1988
ITEM A5:LAT AND LONG DEPICTED FROM GOOGLE EARTH
ITEM A9:GARAGE HAS 2 ENGINEERED SMART VENTS MODEL#1540520 INSTALLED IN LEFT SIDE AT GARAGE FLOOR
LEVEL,EACH VENT COVERS 200 SQUARE FEET OF FLOOD COVERAGE,GARAGE DOOR HAS 2 NON-ENGINEERED AIR VENTS
INSTALLED EQUALING 44 SQUARE INCHES
ITEM C2e:A/C EQUIPMENT LOCATED ON LEFT SIDE OF HOUSE
FEMA Form OWO-33(7/15) Replaces all previous editions. Page 2 of 7
ELEVATION CERTIFICATE OMB No0NoB
Expirationn DDate:November 30,2018
IMPORTANT:In these spaces,copy the corresponding Information from Sesdon A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unn,Suite,and/or Bldg.No.)or P.O.Route and Box No. Policy Number:
355 WEST Sac STREET
Cm, State ZIP Code Company NAIC Number
ATLANTIC BEACH FLORIDA 32233
SECTION E—BUILDING ELEVATION INFORMATION(SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A(WITHOUT SFE)
For Zones AO and A(without BFE),complete Items Et—E5.If the Certificate is intended to support a LOMA or LOMR-F request,
complete Sections A, B,and C.For Items EI—E4,use natural grade,if available. Check the measurement used. In Puerto Rim
only,enter meters.
Et. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below
the highest adjacent grade(HAG)and the lowest adjacent grade(LAG).
a) Top of bottom floor(including basement,
crawlspace,or enclosure)is WA ❑feet ❑meters ❑above or ❑ below the HAG.
b) Top of bottom floor(including basement,
orawlspace,or enclosure)is WA ❑ feet ❑ meters ❑ above or ❑ below the LAG.
E2.For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 1-2 or Instructions),
the next higher floor(elevation C2.b in
the diagrams)of the building is WA 0 feet ❑ meters ❑shove or ❑ below the HAG.
E3.Attached garage(top of slab)is N/A ❑feet ❑meters ❑ above or ❑ below the HAG.
E4.Top of platform of machinery and/or equipment
servicing the building is N/A ❑ feet ❑ meters 0 above or ❑ below the HAG.
E5.Zone AO only: If no flood depth number is available,is the top of the bottom floor elevated in accordance with the community's
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F—PROPERTY OWNER(OR OWNER'S REPRESENTATIVE)CERTIFICATION
The propertrtyy owner or owners authorized representative who completes Sections A.B,and E for Zone A(without a FEMA-issued or
mmmunity-issued BFE)or Zone AO must sign here.The statements in Sections A, B,and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
Address Cay State ZIPCode
Signature Dale Telephone
Comments
❑ Check here if attachments.
FEMA Forth 0860-33(7/15) Replaces all previous editions. Page 3 of?
ELEVATION CERTIFICATE OMB No. 16600008
Expiration Date:November 30,2018
IMPORTANT:In these spaces,copy the corresponding irdorma4on from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O. Route and Box No. Policy Number:
355 WEST 3so STREET
CM State ZIP Code Company NAIC Number
ATLANTIC BEACH FLORIDA 32233
SECTION G-COMMUNITY INFORMATION(OPTIONAL)
The local official who Is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A,B,C(or E),and G of this Elevation Certificate. Complete the applicable tem(s)and sign below. Check the measurement
used in Items G"10. In Puerto Rico only,enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer,or architect who is authorized by law to certify elevation information.(Indicate the source and date of the elevation
data in the Comments area below.)
G2. ❑ A community official completed Section E for a building located in Zone A(without a FEMA-issued orcommunity-issued
BFE)or Zone AO.
G3. ❑ The following information(Items G4-G10)is provided for community floodplain managementpurposes.
G4. Permit Number G5. Date Permit Issued G6. Date Certificate of
Compliance/Occupancy,Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as-built lowest floor(including basement) ❑ feet ❑ meters Datum
of the building:
Gg. BFE or(in Zone AO)depth of flooding at the building site: ❑feet ❑ meters Datum
G10.Communitys design flood elevation: ❑feet ❑ meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments(including type of equipment and location,per C2(e),if applicable)
❑ Check here if attachments.
FEMA Form 086-0-33(7/15) Replaces all previous editions. Page 4 of 7
ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS OMB No. 1660-0008
See Instructions for Item A6. Expiration Date: November 30,2018
IMPORTANT:In these spaces,copy the corresponding information from Section A. rINSURANCE COMPANY USE
Building Street Address(including Apt.,Unit,Suite,and/or Bldg. No.)or P.O. Route and Box No.355 WEST 3RD STREET
City State ZIP Code umber
ATLANTIC BEACH FLORIDA 32233
If using the Elevation Certificate to obtain NFIP flood insurance,affix at least 2 building photographs below according to the instructions
for Item A6. Identity all photographs with date taken; "Front View' and 'Rear View'; and, if required, 'Right Side View" and "Left Side
View."When applicable,photographs must show the foundation with representative examples of the flood openings or vents,as indicated
in Section A8.If submitting more photographs than will fit on this page,use the Continuation Page.
Photo One Caption FRONT VIEW 4-23-2019
Photo Two Caption RIGHT SIDE VIEW 4-23-2019
FEMA Form 086.0-33(7/15) Replaces all previous editions. Page 5 of 7
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE See Instructions for Item A6.
Expiration Date: November 30, 2018
IMPORTANT:In these spaces,copy the corresponding Information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit,Suite,anNor Bldg. No.)or P.O. Route and Box No. Policy Number:
355 WEST 3f°STREET
City State ZIP Code Company NAIC Number
ATLANTIC BEACH FLORIDA 32233
If submitting more photographs than will fit on the preceding page,affix the additional photographs below. Identify all photographs with:
date taken;"Front View"and"Rear View";and, g required,"Right Side View"and"Left Side View."When applicable, photographs must
show the foundation with representative examples of the flood openings or vents, as indicated in Section Aft.
l _
nmr
Photo Three Caption LEFT SIDE VIEW 4-23-2019 ( 2 SMART VENTS)
was
MEN
Photo Four Caption REAR VIEW 4-23-2019
FEMA Form 086-0-33(7115) Replaces all previous editions. Page 6 of 7
ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS OMB No. 1660-0008
See Instrwtions for Item A6. Expiration Date: November 30,2018
IMPORTANT:In these spaces,copy the corresponding information from Section A FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit,Suite,ancVor Bldg. No.)or P.O.Route and Box No. Policy Number:
355 WEST 3P0 STREET
city State ZIP Code Company NAIC Number
ATLANTIC BEACH FLORIDA 32233
If using the Elevation Certificate to obtain NFIP flood insurance,affix at least 2 building photographs below according to the instructions
for Item A6. Identify all photographs with date taken; "Front View' and"Rear View'; and, it required, "Right Side View' and 'Left Side
View.'W hen applicable,photographs must show the foundation with representative examples of the flood openings orvents,as indicated
in Section A8. If submitting more photographs than will fit on this page,use the Continuation Page.
Photo Five Caption SMART VENT MODEL#1540-520 (2 IN GARAGE)
Photo Six Caption VENTS IN GARAGE DOOR (2)
FEMA Form 086-0-33(7/15) Replaces all previous editions. Page 7 of 7
m ' �
/ L
� m
r
r �
I 1
' T
4
N a
1 i N 2
rm
� m mm a
m yn
ic m 'z `.
A- - TULIP ST i TULIP ST
y N i O
O BEGONIAST '
4 / r m i
mDy
mf /
J JASMINE ST
.A y�.Tiilr _�
r
� P
' CAMELIA ST �
y,. O
N N
^ O^
MOAN •� ,.- + ' r Z r Z
' ST m m
=+ D O1D
m m
m O y / :..y
Z m
J f 4 ,D )R. .yam a STOCKS ST
m D i o c7:'lud+�� �'a.]
IU
mp
a.I I y
N , 1 • Y q rO 1
n ' 'HaYapRJgp
N
"0 Orv = mZ
Ap F N r m
a
3a�q: n
r
MTI
a3 Sd m O
➢1�,U O
1 ! r Z
(n
C
I W o ai Z
9z91a m R1
m
Aea$ o
ESERVVALUATION
.
EvaluationCE
Report
ICC-ES 1 (800)423-6587 1 (562) 699-0543 1 www.icc-es.org This report is subject to renewal 02/2021.
I DIVISION: 08 00 00—OPENINGS
SECTION: 08 9S 43—VENTS/FOUNDATION FLOOD VENTS
REPORT HOLDER:
SMART VENT PRODUCTS, INC.
EVALUATION SUBJECT:
SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS:
MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574;
#1540-524; #1540-514
FLOOD VENT SEALING KIT #1540-526
ICC ICC ICC
PMG
•ten
"2014 Recipient of Prestigious Western States Seismic Policy Council 2��
ix...nTonu
(WSSPCJAward in Excellence" Asuhsidiary of cede caunnr
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not Specifically
addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.
There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this
report, or as to any product covered by the report.
Copyright 0 2019 ICC Evaluation Service, LLC. All rights reserved.
E5
IMES Evaluation Report ESR-2074
Reissued February 2019
This report is subject to renewal February 2021.
www.icc-es.orc 1 (800)423.6587 1 (562) 699.0543 A Subsidiary of the International Code Council®
DIVISION:080000—OPENINGS Each unit is fabricated from stainless steel. Smart Vent'
Section: 08 95 43—Vents/Foundation Flood Vents Automatic Foundation Flood Vents are available in
various models and sizes as described in Table 1. The
REPORT HOLDER: SmarIVENT'Stacking Model#1540-511 and FloodVEN Is
Stacking Model #1540-521 units each contain two
SMART VENT PRODUCTS, INC. vertically arranged openings per unit.
EVALUATION SUBJECT: 3.2 Engineered Opening:
The FVs comply with the design principle noted in Section
SMART VENT®AUTOMATIC FOUNDATION FLOOD 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section
VENTS:MODELS#1540520;#1540521;#1540510;#1540- 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and
511;#1540570;#1540574;#1540524;#1540514 IRC)] for a maximum rate of rise and fall of 5.0 feet per
FLOOD VENT SEALING KR#1540526 hour(0.423 mm/s). In order to comply with the engineered
opening requirement of ASCE/SEI 24, Smart Vent FVs
1.0 EVALUATION SCOPE must be installed in accordance with Section 4.0.
Compliance with the following codes: 3.3 Ventilation:
so2018, 2015, 2012,2009 and 2006 International Building The SmartVENT' Model #1540-510 and SmartVENT'
e( Overhead Door Model#1540-514 both have screen covers
Code (IBC) with '/s-inch-by-'/a-inch (6.35 by 6.35 mm) openings,
■ 2018, 2015, 2012, 2009 and 2006 International yielding 51 square inches(32 903 mm2)of net free area to
Residential Code'(IRC) supply natural ventilation. The SmartVENT' Stacking
■ 2018 International Energy Conservation Code'(IECC) Model #1540-511 consists of two Model #1540510 units
in one assembly, and provides 102 square inches
■ 2013 Abu Dhabi International Building Code(ADIBC)1 (65 806 mm2)of net free area to supply natural ventilation.
hne kDIBC is based on Me 20M 112009 11 time sections remreneee Other FVs recognized in this report do not offer natural
In use report are the same sections In he ADIBC. ventilation.
Properties evaluated: 3.4 Flood Vent Sealing Kit:
Is Physical operation The Flood Vent Sealing Kit Model#1540-526 is used with
SmartVENTs Model #1540-520. It is a HDmasote 440
■ Water flow Sound Barrier' (ESR-1374) insert with 21 – 2-inch-by-2-
2.0 USES inch(51 mm x 51 mm)squares cut in it.Sae Figure 4.
The Smart Vent' units are engineered mechanically 4.0 DESIGN AND INSTALLATION
operated flood vents (FVs) employed to equalize 4.1 SmartVENT'and FloodVENT':
hydrostatic pressure on walls of enclosures subject to
rising or falling flood waters. Certain models also allow SmartVENT' and FloodVENT' are designed to be
natural ventilation. installed into walls or overhead doors of existing or navy
construction from the exterior side. Installation of the
3.0 DESCRIPTION vents must be in accordance with the manufacturers
3.1 General: instructions, the applicable code and this report.
Installation clips allow mounting in masonry and concrete
When subjected to rising water, the Smart Vents FVs walls of any thickness. In order to comply with the
internal floats are activated,than pivot open to allow flow in engineered opening design principle noted in Section
either direction to equalize water level and hydrostatic 2.72.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of
pressure from one side of the foundation to the other.The ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the
FV pivoting door is normally held in the closed position by Smart Vent'FVs must be installed as follows:
a buoyant release device. When subjected to rising water, 0 With a minimum of two openings on different sides of
the buoyant release device causes the unit to unlatch, each enclosed area.
allowing the door to rotate out of the way and allow flow.
The water level stabilizes, equalizing the lateral forces. ■ With a minimum of one FV for every 200 square
ICC-ES Evaloaron Repa.0 one wt to be oov no repenook,imehenu or ary other ami not*ndfY addreved,nos are dry W be roamed
on endommnentofM,nMienofMereyyn or a—sameMon'onfor to wet there irn —ty by ICC E.Wdon Service,LLC,apron or implied as
toa,ryfreing or other motto in N4 real or ar m anypradact covered by the report. o emC➢5
Copyrighte 2019 ICO Evaluation seven.LLC. NI III reserved Pass 1 03
ESR-2074 I Most Widely Accepted and Trusted Page 2 of 5
feet (18.6 m') of enclosed area, except that the 5.2 The Smart Vent® FVs must not be used in the place
SmarIVENT' Stacking Model #1540-511 and of"breakaway walls"in coastal high hazard areas,but
FloodIVENTe Stacking Model #1540-521 must be are permitted for use in conjunction with breakaway
installed with a minimum of one FV for every walls in other areas.
400 square feet(37.2 m')of enclosed area. 6.0 EVIDENCE SUBMITTED
■ Below the base flood elevation. 6.1 Data in accordance with the ICC-ES Acceptance
is With the bottom of the FV located a maximum of Criteria for Mechanically Operated Flood Vents
12 inches (305.4 mm) above the higher of the final (AC364), dated August 2015 (editorially revised
grade or floor and finished exterior grade immediately October2017).
under each opening. 6.2 Test report on air infiltration in accordance with ASTM
4.2 Flood Vent Sealing Kit E283.
The Flood Vent Sealing Kit Model 1540-526 is used in 7.0 IDENTIFICATION
conjunction with FloodVENTe Model #1540-520. When 7.1 The Smart VENT°models and the Flood Vent Sealing
installed and tested in accordance with ASTM E283, the Kit recognized in this report must be identified by a
FV and Flood Vent Sealing Kit assembly have an air label bearing the manufacturers name (Smarivent
leakage rate of less than 0.2 cubic feet per minute per Products, Inc.),the model number,and the evaluation
lineal foot (18.56 I/min per lineal meter) at a pressure report number(ESR-2074).
differential of 1 pound per square foot (50 Pa) based on
12.58 lineal feet(3.8 lineal meters)contained by the Flood 7.2 The report holders contact information is the
Vent Sealing Kit. following:
5.0 CONDITIONS OF USE SMART VENT PRODUCTS,INC.
The Smart Vent' FVs described in this report comply with, 430 ANDBRO DRIVE,UNIT 1
or are suitable altemadves to what is specified in, those PITMAN, NEW JERSEY 08071
codes listed in Section 1.0 of this report, subject to the (677)441-8368
www.smartvent
following conditions: infollDsmarNent.co.cor
m
5.1 The Smart Vent'FVs must be installed in accordance
with this report, the applicable code and the
manufacturers installation instructions. In the event of
a conflict,the instructions in this report govern.
TABLE 1—MODEL SIZES
MODEL NAME MODEL NUMBER MODEL SIZE(In.) COVERAGE(sq.R)
FloodVEN 1540-520 15'/,"X 7/," 200
SmartVENT' 1540-510 153/i X7'/4" 200
FloodVENT'Overhead Door 1540-524 153/4"X 7'/i 200
SmartVENT'Overhead Door 1540-514 153/i X7'/i 200
Wood Wall FloodVENT' 1540-570 14"X8'/4" 200
Wood Wall FloodVENTe Overhead Door 1540-574 14"X B'4" 200
SmartVENT'Stacker 1540.511 16"X 16" 400
FloodVent Stacker 1540-521 16"X16" 400
For 31: 1 Inch 25.4 mm;i square foot=m'
FIGURE 1—SMART VENT:MODEL 1540-510
ESR-2074 1 Most WdelyAccepted and Trusted Page 3 of
FIGURE 2--SMART VENT MODEL 1540.520
_J
FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN
INTERIOR EXTERIOR
FIGURE 4—FLOOD VENT SEALING KIT
E�
Mo<t Widely Accepted and TLISted
ICC-ES Evaluation Report ESR-2074 CBC and CRC Supplement
Reissued February 2019
This report is subject to renewal February 2021.
www.icc-es.orq 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the Intemational Code Councils
DIVISION:08 00 00—OPENINGS
Section: 08 95 43—Vents/Foundation Flood Vents
REPORT HOLDER:
SMART VENT PRODUCTS,INC.
EVALUATION SUBJECT:
SMARTVENTs AUTOMATIC FOUNDATION FLOOD VENTS:MODELS#1540520;#1540-521; 111540510;#1540311;#1540-
570;#1540374;#1540524;#1540514
FLOOD VENT SEALING KR#1540526
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents,
recognized in ICC-ES master evaluation report ESR-2074, have also been evaluated for compliance with codes noted
below.
Applicable code edition:
■ 2016 California Building Code(CBC)
■ 2016 California Residential Code(CRC)
2.0 CONCLUSIONS
2.1 CBC:
The Smart Vents Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report
ESR-2074, comply with 2016 CBC Chapter 12, provided the design and installation are in accordance with the 2015
International Building Codes(IBC) provisions noted in the master report and the additional requirements of CBC Chapters
12, 16 and 16A,as applicable.
The products recognized in this supplement have not been evaluated under CBC Chapter 7A for use in the exterior design
and Construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any
Wildland-Urban Interface Fire Area.
2.2 CRC:
The Smart Vanle Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report
ESR-2074, campy with the 2016 CRC, provided the design and installation are in accordance with the 2015 International
Residential Code (IRC)provisions noted in the master report.
The products recognized in this supplement have not been evaluated under 2016 CRC Chapter R337, for use in the
exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas
or any Wildland-Urban Interface Fire Area.
The products recognized in this supplement have not been evaluated for compliance with the international Wildland-Urban
Interface Code".
This supplement expires Concurrently with the master report,reissued February 2019.
rcc-M amaaean sspom ase„arm be-a, aaerw.e..enn,000hevora.amaiw aroibm.e norm«lieanraddre ea nae ase rbyrobe renrnwd Ella
mdomane,uofMenblut lee exon or a re.ommendwianJoritr we lberzY no waewnry by ICC Evahun'on Swire,LLC e.pw.oe implied,m
.o oo fiMneorohe oianoin Ne won,,or w on arypwoutroveeedbythe won.. P-W —
Copyright a 2019 ICC Evaluation Service,LLC. NI rights rmorwo. loa9a 4 of 5
ES
Most Widely Accepted and Trusted
ICC-ES Evaluation Report ESR-2074 FBC Supplement
Reissued February 2019
This report is subject to renewal February 2021.
www.icc-es.ora 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the International Code Councils'
DIVISION:08 00 00—OPENINGS
Section: 08 95 43—Vents/Foundation Flood Vents
REPORT HOLDER:
SMART VENT PRODUCTS,INC.
EVALUATION SUBJECT:
SMART VENTS AUTOMATIC FOUNDATION FLOOD VENTS:MODELS#1540-520;#1540-521;#1540510;#1540-511;
#1540570;#1540-574;#1540-524;#1540514
FLOOD VENT SEALING KR#1540-526
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that Smart Vere Automatic Foundation Flood Vents,recognized
in ICC-ES master report ESR-2074, have also been evaluated for compliance with the codes noted below.
Applicable code editions:
■ 2017 Florida Building Code—Building
■ 2017 Florida Building Cods—Residential
2.0 CONCLUSIONS
The Smart Vents Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report
ESR-2074, comply with the Fonda Building Cods—Building and the FRC, provided the design and installation are in
accordance with the 2015 International Building Code provisions noted in the master report.
Use of the Smart Vents Automatic Foundation Flood Vents has also been found to be in compliance with the High-Velocity
Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building Code—Residential.
For products falling under Florida Rule 9N-3,verification that the report holders quality assurance program is audited by a
quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the
responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by
the Commission).
This supplement expires concurrently with the master report,reissued February 2019.
ICC-ESEvvfuwmnRgaro ore notmbe scrum,Mwrepresentilgvertbm'vwanyalFnumibwv w,�AsdlY SH4rsveq caw welbryrobe roiwrve6 i
weedorseme,u lae,abJros oJMs repanararecammeManan/or itr welFrie Uno warronN by ICC EMhoHonSwice,LLC,apros ar imph'sd,m
ro agfiMingsrarMmaaer in Mu reyort,oras m anypmdxrrovvep by Me rgort. __
CopyNaht02019ICC Evaluation Service,LLC. NI,IgNe reeervaU. piigisof4