Loading...
155 Magnolia St RERF19-0076 Shingle REROOF SHINGLE PERMIT PERMIT NUMBER 1 RERF19-0076 CITY OF ATLANTIC BEACH ISSUED: 5/24/2019 800 SEMINOLE ROAD EXPIRES: 11/20/2019 ATLANTIC BEACH.FL 32233 INSPECTIONMUST CALL • . I , • • ` ALL • • • • •EDITION1 CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMITTYPE: DESCRIPTION: VALUE OF WORK: shingle re-roof FL10674.1 & 4440.00 I55 MAGNOLIA ST REROOF SHINGLE ASTM D226 $ TYPE OF REALESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: G I ROUP: 170626 0005 SALTAIR SEC 03 COMPANY: ADDRESS: Tadlock Roofing, Inc. 1408 Capital CIR NE Suite#3 TALLAHASSEE FL 32308 OWNER: ADDRESS: KERR PAUL G 155 MAGNOLIA ST ATLANTIC BEACH FL 32233-4005 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list. Container cannot be placed on City rightof-way. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 4550000-333-SOW 0 $7500 $TATEDBPR SURCHARGE 4550000-208-0700 0 $200 ST AT OCA SURCHARGE 455-0DW 208-0600 0 $300 TOTAL:$79.00 Issued Date:5/24/2019 1 of 2 OLBuilding Permit Application uaxotedtay„a CRY of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road,Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904)247-5826 Email: BuildinR-Dept coab.us IIS REQUIRED, Job Address: 165WAW"Ur Akt&BmclFL=33 permit Number:_j� �Lq—M Legal Description 1D1121-q&TaE RALTA1R6ED3 Btn LOTH MEg 1708264=6 —_— VduaeanpfWarklRedxeennotowt)s 4,440116 __Heated/fouldeSFIM 1,100,1,100,He*tWCooleL6 • Classof Work: QN/ew OAdditlon OAlteratlon @Repair ❑Move ODemo OPod OWndow/Door • Weofexlsting/propwedstrudure(s): OCommndal mRsldential • Ifane $Urigstrudure,iserrresprkklersysteminstalled7: OYes ONO ill re r m v i U n nlr IY Tr R may I P r DesaiTebdatdl lie type ofwork tobeperfumed: r RFxotH 4.5 slope with a 9 sqs of Oaltrid a Architectural shingles Florida Product Approvalp FI16624.1 ASTM)-)72_Le for meNlple Products use product appravdform Property Owner Information Name P6d Ran Address 156MAONMAST qty,AYan6e BeWr state R Zip 97273 Phone pD671gMD E-Mail imrMM�mrroel.M Owner or Agent(IfAgent,Power of Attomey or Agency Letter Required) Contractor Information Name of company TAdockRoadng pea qualifying Agent O T*d p Address Tt49 Ph6ps Highway that OilGly J&dowwas Staten LD 929N Office Phone Soo-33e52W _.___Job Site Contact Number a 64en4a617 StateCerUflation/Registratlonp C=329417E.1IudyOUdaduaaRq.00m Architect Name&Phone p Engineer's NameB Phpnep )� Workers C ddpensaftm Insurer FRSA ON Exempt Expiration Date Zo2_ Application is hereby made to obtain a permit to do the work and installations as indicated.I certi y that no work or instal lation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this Jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES.BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc NOTICE:In addition to the requirements ofthls permit,there may be additional restric dons applicable to this property that may be found In the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and coning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECO ONG YOUR NOTICE OF COMMENCEMENT., --- �F ) i4, 4 t ICv1�X @L� f ISI6rotare0f� (Slpwtureof Contractor) Signed and swan to for affirmed)before\thlsca day ofr Signed and sworn to for affirmed)before me tha�day of (Slgrp ree„KranY,�pica ISlpna re 0”, 4;%) )Perwnally Known OR Per ally mown OR ducedlde711ft.ioq.-, ; qq, JUDYLgRAlia 2 rvce ofiaentmcatlom VLA- Downis"gOD2OW ( IPrud ed ldera9catlon .; (Ky..� AWYL BRANIIEY 1.:3, v %.ExpkatJyly31,�Y4_ Type ofl ntlficanon a' he CmuNUImgGG2431164 .,...I angdrnuTwJferhwrnw NhNls ''v •y''Ex0NSJu1f31,2622 ....q,.h..r eadeemarpyrwwyrmR7RSTHa Recorded 05/14/2019 09:09 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY REC053DING $10.00 Permit No Tait Fish.No - 170826-0005 _ NOTICE OF COMMENCEMENT State of FLORIDA Duval County of The uWenigned hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes.the f91l9wing infomtation is provided In this Notice of Commencement. I. Description of property: LEGAL DESCRIPTION AppgE�� 10.16 21-28-29E SALTAIR SEC 3 51/2 LOT 859 155 MAGN%LIA ST ADantic Beach FL 32233 2. General description of improvement R roM 3. Owner Information or Lessee Information if the Lessee contracted for the ImprovemNiL a. Nam!and address:.HERR PAUL G iS5 MAGNOLIA ST A b. Interest in property: c Name and address of fee simple tidMolM Df dl(ferrmg frmn Owner IMted Mamie): 4. a. Contractor: TADLOCR ROOFING, INC., 502 CAPITAL CIRCLE SE,UNIT C4,TALLAHASSEE,FL 32301 b. Contractor's phone ntmaer.850-977.5516. 5. Surety(if app(icabie,a copy of D-e payment bond is attached): A. Name and address: b. Phone number C. Amount of bond:$ 6. a. Linder: b. Lender's phone number. 7. Persons within the State of Florida designated by Owner upon wham notices or other dutmments may be served as provided by Section 13.1 111 al 17..FI�AStg�us: a. Hame and address: NkAaal _ b. Phone oumbers of del"tiated persons: 994-742-6413 8. a. M addition to himself or herself,Owner designates of to receive a copy of the Uermr's Notice as provided in Section 713.13(0(b),Fiends Statutes. b. Phone number of person or entity designated by owner- .. 9. Expiration date of notice of cgnmencement(the expiration date wIU be 1 year frau the date of recording unless a different date is SWIRadl _ WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART), SECTIO!711-13 FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYNO TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A HOrICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WOR OR ECORDING YOUR NOTICE OF COMMENCEMENT. ®® /tf a 0-4— (S*Wtwe of wner of Lessee, a Ovmer's dr Lessee's Authorized Officer/Dire twi Partner/ MaMger) (Signatory's Title/Office) The for mstnynent was aUutowledged before me this III of �"I . loij, .. SIT, \ YtP f f L><,vi as . .yam— for t F lureture of��ary Public-State of Flprida)Public-State of Raida) lly�i_ OR produced IdmUll<atlon .:A or. CoaarY+bo 6ii83131e/ ofldenti Von Produced �L- i., ®a OyWsJury3l,mII 'aa=�.� aormm.TMTwwaneupmmN � } )] \ ■ ! c 2 k � « 7 S Mm . � ffJ kmo coLU ) \k ) k � \ \\ k iii ! o ; ) @ E _ § � _ x _ _ _ ! � vi /\\ § .S ) R ) § k ) \ � ) \0 | ci- 2 ) ki � , k } /ƒ\ k _ \ « r ) !_ ! .2 ) ! ; ! 28 � � � � _ § % 0 f ! ; � ■ , � ® ■ � 2 - 2 , = = = � + 27 » K � � \ } \] k } 21142 ; ; � § / ! lm2m k { | ! 7 ! t # ! � k � f . ! , 2 , � � � ■ ; § / § ■ , ( \ , ) { 221k ] a7 a � , < ! ` 2 :E = 4E � ! ! _ I ` ! � . _ . E � , _ � , , § , ! � 2 ` - • ° ■ & e � ! ! � � � ) ) £ a � = a , � 2le | q , e , gf9l ; § « ow4i ® -4ej , � � � � „ - 0 _s x m N C yO A r E c w f r c 96 c q o m c g 0 � O m ,al S C Lq c s ° P Sg 3 cc F uc� 'c4 9 8 E S s o 3 s s 9 IR = Q m VI fL W c p O rl N M W y y� ei N M V Vl lC 1� L r4 O N M O 1!1 W n w 01 ei ei ei N0 4 N L > ei N W LL U S W \) } ( \_ §OR K 046 ) ) ! { § £ R - 7 � : \ ! 64 t � om cc kmw at \ \ \ \ \fj f \ o � k a } Z § ) R t ® 8 \ - E r « k ) \ 0 2 � \ » } - ; ! ; §7 ) F : \ EI(TERIOR RESEARCH&DESIGN,U.C. certftateofAuHroruorions9503 TRINITY ERD 353 CHRISTIAN STREET,UNIT#13 OXFORD,Cf 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R8 One Owens Corning Parkway F1.70674R13 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)4047829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 63620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6t° Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the referenced Quality Assurance documentation changes. TrinityIERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERnSEMENT: The Evaluation Report number preceded by the words"Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. I, Prepared by: rm....:n.:,+—' ,ap �lfirti.- i�OE Robert J.M.Nieminen,P.E. meravientle seal aspearin,was awbamed by Robert Florida Registration W.59166,Floddo OTA ANE103 '^�4�^,J Madison,I E.an 10/OR/] IT This over not urn as an ele odninIly siined domment. CERn OMON OF INDEMPIDEXEE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This Is a building rode evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the 616 Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R9p5.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,8905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Emil Examination Reference Date UL LLC(CER%26) Physicals&Wind Resistance File 82453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance IICA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FIC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCE DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire-are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, Tru0efinition Duration, Duration Premium Cool, Tru Definition Duration Designer Color Collection, TruDefinition Oakridgee, Oakridge and WeatherGuard HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip& Ridge Shingles, ProEdge Hip& Ridge Shingles and Durallidge-Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMDATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Eaterior Research Roof Design,I.I.C. Evaluation Repan 037940.02.12-R8 [mylmre a),lurhaHaarM I95p3 6r"EDITION 120171 EIC NON HVHZ EVALUATION FL1067&R13 Owens Coming Asphan Rauf Sliftles Revision 8:10/0912017 Page 2 of 9 QTRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones up to V,aa = 150 mph (V„I6 = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Va,a=150 mph(V„n=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM 07158 applies to exposure category B at C, as defined in FBC 1609.4.3,and a mean roof height of 60 het or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Coming published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: y.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Coming and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 63G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturers published requirements, but not less than FBC 1507.2.6 or 8905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: faYradPlwenn Dd rx.rgR.ax m r.rr wrma Sararm xaahlrlr rrvh.tn,t• �e.upnern _ d0a D� DV9 aara6w -gyh looml rr� r-rnarn e,.. Inalagfirat 6;K ssafn9 aarar< Irxfim6unm6mp lYa papx„[xN�,r $r Mer Wbp�� WailianN abn9em n6'mmas] aMnde 6F 6 ,emorM fitaT 6by+liiNle or^,Irg.nrn ad rates ,•'� earn ti^wlr4wN,b Va'-aM Exterior Revearch and Deus ,LLC Evaluation Report 031940.01.12-RIS axn;rxme x9503 6"EDITION 110171 FBC NON-NVN2 EVALUATION FL10674R13 owem coming Asphalt Roof shIMIes Revision g:10/09/1017 Page 3 of g TRINITY ERD 6.2.6 Minimum Nailing—Classige&Supreme: FWnW erraw Neapr. Norm•I m.n.•.a o, A.•• Unca w�• SR N,*wwN Owr•s•Y WinEri NigL w Ari M .•m. • y MIn�MMfw uanel� Anaa •Mrw MM. Aw V•r•vnini nwm•/w N•.. ri•nrea brt•• rlLgr. giyg'flggaNr. gNfA.NY. lMYF2P 6.2.7 Minimum Nailing—Berkshire•: snail awhxrrelp 4hdinUa y YY•b.ib 9vf 6w sw ( l_iN' aw FM LY 1•J 1 r• Standard Fastening Pattern 6-Nail Fastening Pattern snari urn'.. Tvtr etr eur s'r r ,1iFaaL wIYN®a EoabblsAo6 WW Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 0379e0A1.11-M Certlfam gauMotleo."503 6r"EOITION 130171 FBC NON-HVH3 EVALUATION FL10671R33 Owens Gaming Asphalt ROOT Shingles Recision g:10109/2017 Page 4 of 8 TRINITY ERD 6.2.8 Minimum Nailing—Devonshire-: 7, 8' 8" sells Shcr aWRln sealant lolladotavon bpakidn de5blg W4 Ibludon del ser Tml' b IlaMfaiwn Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration*, TruDefinitiona Duration, Durations' Premium Cool & TruDefinition Duration Designer Color Collection: esaraesnseg p axr rewrWiq rysn t..n..�e...w. ...��v...r� sn,e• r+ww -r:- F1 F1 Standard Fastening Pattern 6-Nail Fastening Pattern r�,waw r tsve on�w nw�al:ss EJT Air Mansard or Steep Slope Fastening Pattern EMenor Research and Design,U.C. Es.IuRtI..Report O3M .0E.1Z-R8 cmOkobo)<uXmrse.09503 6T"EDITION IZO171 FBC NON-HVHZ EVALUATION FL30634R33 Owens Coming Asp6ak Roof Shingles Revision 8:10/09/2013 Page s of 8 �l I MNIIY ERD 6.2.1 Minimum Nailing-TruDeNnition Oakridge•,Oakridge•: a Nall Palm rNallPatam Esgrmarangdaaus EsesalN amgNans 1' f ¢ '—ei P6pna gsN'Expw 6ymWla 05EFYpfB EY EiWsleronh 55ieV'I4 6E9'hp®N 45s 66A'EPw 66Kpdp &p.N6MHENpIg EgvMn Standard Fastening Pattern 6-Nail Fastening Pattern FeYnN01u sh W a..31:11 T W war Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuarde HP: fe— �.:• ::�:f: LrrlYay�YEYF anaa�Yi�il�Iga Eaterlor Research and Design,I.I.C. Evaluation Report 03 RIa0.@.12-RT Certl/Icore o)AUNwOoabn9$03 6-EDITION 120171 PTC NON-HVHE EVALUATION fllMT R33 Owens Coming Asphalt Raaf Shingles Revlsbna:1O/03/2017 Page 6 of 8 TRINITY ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge" Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information On wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 15W.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire°Hip&Ridge and High Ridge: Flg.l 4 o_aaaIwva //�\ p\ \ N•vw awn i i t r 6.3.4 Minimum Nailing—WeatherGuard•HP Hip and Ridge: Fig.C Hip g Ridge Shingle Fastening Fig.AF�•w � mavw we r r9... 1 e w Extedur Research and Design,LLC. Evaluation Nation 031900.02.13-Ad [erty/mfeofAUMw4oHon n503 6'-EDITION 130171 FRC NON-HVH3 EVALUATION F110614R13 Owens Corning Monett Roof shingles Revision 8:10/09/3037 Pap 7 of 8 CFT RINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: P.evailinB F�bning X11' ViDirwtlDll ad.n aBip PnlbrnLT �� F »� �/ a•Egave I I'•I FI I-r F4F1as IS' rEsRrrn 1r� 6.3.6 Minimum Nailing—DuraRidge—Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. M1w� NnWnY�wYPr4wwx^ I �� I •I I I L i � 31y 88 ��l4i 1 "�3 I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 914-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA962S;(633)546-2458;Kanchi.Agrawala-Dokania@ul.com - ENO OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report 037W.0.12-RB [etll/kore ofaufhwkoWn49503 fir"EDITION(3017)FBC NON-HVH2 EVALUATION FL10674-Rf3 Owens Corning Asphatt Rood Shingles unnswn B:10/09/2017 18 od8 ® MICOUNTY CONTROL PRODUCT CONTROLL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(EER) 11805 SW 26 Saeet,Rao.208 BOARD AND CODE ADMINISTRATION DIVISION Mivai,Flonde 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www m am aade.eov/ceoaomv Owens Coming Roofing and Asphalt,LLC. One Owens Corning Parkway Toledo,OH.43659 SCOPE: This NOA is being issued under the applicable odes and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHI). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHD(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ProArmor—Synthetic Roof Underlayment LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of[his NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the wards Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 141215.05 and consists of pages I through 3. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0124.02 MIAMLDADr COUNTY Expiration Date: 11/12/20 ®' Approval Date: 01/25/18 Page 1 of 3 ROOFING COMPONENT APPROVAL Careen": Roofing Sub-Cateeorv: Underlayrrent Material: Polyolefin SCOPE: This approves ProArmorTM Synthetic Roof Underlayment, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description ProArmorrm Synthetic 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment coated with Roof Underlayment 25 lbs.per roll Type II UV protected and slip resistant polymer stabilized polyolefin. MANUFACTURING LOCATION: 1. M.L.#1 EVIDENCE SUBMITTED: Test Aeencv Test Identifier Test Name/Report Date Intertek Testing Services NA LTD 102783795COQ-004 ASTM D 226 11/11/16 INSTALLATION SPECIFICATIONS: (Single Layer: Slopes of 2:12 or greater) 1. PmA not°M Synthetic Roof Underlayment shall be installed in strict compliance with applicable Building Code. 2. ProArmorm Synthetic Roof Underlaymeat shall be installed with a minimum 4-inch horizontal lap and 6-inch vertical laps in a shingle layer fashion. Vertical laps in a succeeding course shall be staggered from those in preceding course by minimum 6-feet. 3. ProMnor—Synthetic Roof Underlayment shall be fastened with approved roofing nails and tin-caps spaced 6"o.c.at all laps and three staggered rows fastened 12"o.c.in the field of the roll. 4. PmArmorTm Synthetic Roof Underlayment may be used with Asphaltic shingles,Wood shakes and shingles, Non-structural metal roofing,and quarry slate. 5. For fire classification of specific roof assemblies using ProArmorT Synthetic Roof Underlayment refer in a current Approved Roofing Materials Directory for fire ratings of this product. NOA No.: 17-0124.02 niAm.onpr COUNT Expiration Date: 11/12/20 ®" Apprmral Date: 01/25/18 Page 2 of 3 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not pan of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3, ProArmcana Synthetic Roof Underlayment shall be applied to a smooth,clean and dry surface with deck free of irregularities.All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4, ProArmorna Synthetic Roof Underlayment shall not he hot mopped,refer to manufacturer's published literature for product compatibility. 5, ProArmofoa Synthetic Roof Underlayment shall not be applied over an existing roof membrane as a recover system. 6, ProArmorTsr Synthetic Roof Underlayment shall not be left exposed as a temporary roof for longer than 90 days of application. 7. ProArmofoa Synthetic Roof Underlayment are components used in roof system assemblies.Roof system assemblies are approved under a specific Notice of Acceptance.Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8, ProArmorTM Synthetic Roof Underlayment may be used with any approved roof covering Notice of Acceptance listing ProA:morna Synthetic Roof Underlayment as a component part of an assembly in the Notice of Acceptance. If ProArmorra Synthetic Roof Underlayment are not listed,a request may be made to the Authority Having Jurisdiction(AAJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. 9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61020-3 of the Florida Administrative Code. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,state and the following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. tuMn M. END OF THIS ACCEPTANCE NOA No.: 174124.02 ninneonor courvTv Expiration Dole: 11/12/20 ®' Approval Date: 01/25/18 Page 3 of 3 MIAMI-DARE COUNTY MPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 So=i,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Flonda 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (LOA) www.miamid&di,aoy/eeoRoMy Owens Corning 1 Owens Corning Parkway Toledo,OR 43659 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHI). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AM may immediately revoke,modify,or suspend the use of such product or material within theirjurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:VentSure Ridge Vent LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date maybe displayed in advertising literature. if any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA#07-0125.01 and consists of pages I through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0309.02 MIAMIDADECOUMrr Expiration Date: 10/31/13 Approval Date: 10/18/12 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Material: Plastic Minimum Slope: 3:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Dimensions Test Product Specification Description Vent Sure Ridge Vent I I!!/."wide, TAS 100(A) Ridge ventilation system. 5/8"high, tenths of 4' &8' Vent Sure Rigid Roll 11!/."wide, TAS 100(A) Ridge ventilation system. 5/8"high, tenths of 20'&50' TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Test Product Product Dimensions Specification Description Manufacturer Asphalt Roof Cement ASTM D 4586 Asbestos-free,asphalt based Generic roof cement. Asphalt Primer ASTM D 41 Asphalt Primer Generic Roofing Nails Minimum# 12 TAS 114 Corrosion resistant annular ring Generic shank nails Sheet Metal Screws Minimum#10 TAS 114 Sheet metal screw generic MANUFACTURING LOCATION 1. Baidwyn,MS EVIDENCE SUBMITTED Test Agency/Identifier Name Report Date Omega Point Laboratories,Inc. ASTM D 1929-91 163332-109020 06/11/01 ASTM D635 163332-109022 06/11/01 ASTM D 2843 163332-109021 07/11/01 Architectual Testing Inc. TAS 100(A) 01-38660.04 0425/01 Architectual Testing Inc. TAS 100(A) 01-38660.05 04/25/01 NOA No.: 12-0309.02 MIAMI DADE COUNT Expiration Date: 10/31/13 ®" Approval Date: 10/18/12 Page 2 of 4 APPROVED APPLICATIONS Tradename: Vent Sure Ridge Vent&Vent Sure Rigid Roll System Type: Mechanical attachment of ridge vent system over composition shingles. Cutout: 1. Determine whether the rafters are truss or ridgepole construction. Cut sheathing 2"(truss)or 3-1/2"(ridge pole)wide slot(1"truss or 1-3/4"ridge pole on each side) of the ridge(s). A minimum of 6"must be left uncut on each end of the ridge. Once the slot is cut and any overlapping shingles covering the ridge are trimmed and removed,the ridge is ready for vent installation. Installation: 2. Place the Vent Sure Ridge Vent or Vent Sure Rigid Roll vent,routed side down along entire length of slot also covering the 6"minimum uncut ridge on both ends. Multiple lengths of vent can be joined by butting them together. 3. Pull apart a 3"or 5-1/4"precut section of the foam endcap. r/' r Using construction adhesive or sealant caulk,insert the r endcap into the end of the vent. Using four(4)2" y Y galvanized roofing nails,attach vent to the roof deck by _ driving a nail in each of the two comers on both ends of the \ vent,and a nail at each side through the foam cap. 4. After vent has been installed,cut ridge shingles,preform, and nail with roofing nails in a common overlapping 1 pattern. Nails should be approximately 5"apart and long '. enough to penetrate the wood roof deck at leas[%:". Repeat this procedure until vents have been installed over all roof ridges. Net Free Area: Refer to manufacturers published literature LIMITATIONS: 1, Refer to applicable Building Code required ventilation. 2. Ridge Vent shall comply with applicable Building Code. 3, Ridge Vent shall not be installed on roof mean heights greater than 33 feet. NEA No.: 12-0309.02 MIANIDADECOVNT Expiration Date: 10/31/13 Approval Date: 10/18/12 Page 3 of 4 DETAIL A VENT SURE RIDGE ROLL AND VENT SURE RIGID ROLL 20 50 an n L END OF THIS ACCEPTANCE NOA No.: 12-0309.02 MIAMIDF®UNIT Expiration Date: 10/31/13 Approval Date: 10/18/12 Page 4 of 4