159 Magnolia St RERF19-0075 Shingle REROOF SHINGLE PERMIT PERMIT NUMBER
} ,. mRERF19-0075
CITY OF ATLANTIC BEACH ISSUED: 5/24/2019
800 SEMINOLE ROAD EXPIRES: 11/20/2019
ATLANTIC BEACHALL .FL 32233
WORK MUST CONFORMTO ' • • • 1 1)'M
• ' • `
CODE, NEC, IPMC,AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPIL Y, PLEASE READ CAREFULLY.
r:In addition to the requirements of this permit,there maybe additional restrictions applicable to this property
ay be found in the public records of this county,and there may be additional permits required from other
mental entities such as water management districts,state agencies,or federal agencies.
shingle re-roof FL10674.1 & $4440.00
159 MAGNOLIA ST REROOF SHINGLE ASTM-D224
TYPE OF • SUBDIVISION:SE
CONSTRUCTION: NUMBER: ZONING: GROUP:
170626 0000 SALTAIR SEC 03
COMPANY: ADDRESS: CITY: STATE:
Tadlock Roofing, Inc. 1408 Capital CIR NE Suite#3 TALLAHASSEE FL 32308
OWNER: ADDRESS:
KERR MICHAEL 1119 PERREGRINE CIR E JACKSONVILLE FL 32259-2966
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF . .
Roll off container company must be on City approved list. Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT I QUANTITY PAID AMOUNT
$1,00
BUILDING PERMIT
455-IXICOd22-1000 0 $2 0 $x.00
STATE DEER SURCHARGE I 455-0000-208-0/UU I
$3 00
STATE DCA SURCHARGE 455-0 208-0600 0
TOTAL:$79.00
Issued Date:5/24/2019 1 of 2
Building Permit Application Wntrd 10/9/11
City of Atlantic Beach Building Department "ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
Phone: (904) 247-5826 Email: Building-Deot(G coab.us IS REQUIRED.
JobAddress: 158 MAGNOLIA STAtlanuc Beach FL 32733 Permit Number'
Legal Description 10462142S19E.057 BALTAR SEC MY 29F'r LLyflSa NEN /7061#-0000
Valuation Of Work(Replacement Cost)$ 4,440.00 Heated/Cooled SF 1252 Nott Heated/Coaled 8
• Class of Work: PJNew OAddlOon OAlteratiunVRepair OMuve ODemo 13POol OWlndow/DborEVE
• Useofevisting/propBsedstructure(Q: OCommemial IgResldential a >,J_
• If an existing structure,is afire sprinkler system installed?: Oyes ONo
• wlilt, rtmgMeOlnciationwriboroco,ed,r 'CY�,tmltseoarateTrRN
Describe In detail the type of work to be performed:
Ro
-rooff 4.5 slope With a 9 Sills of Oakridge Architectural shingles
Florida Product Approval#FI105;4.11 `\iM—�79 zt formulthleprodu -Dull 1119 Li nt
Property Owner Information t ty O /iI18I1TIC each, FL
Name Kdr Address 158MACN ST
City AdmOo BeerA State R 21 37193
E-Mail ketggNN4mrnmMtlat P Phone 904742-0{73
Owner or Agent(If Agent,Power of Attorney or Agency Letter Required)
Contractor Information
Name of Company Taftc,Roofing IM Qualifying Agent OgMTaladt
AddreSS79?aPhRpa Highway UM#211 CM N° Staten Zip 92700
Office Phone 9042365200 Job Site Contact Number 9o1415a-9617
State Certification/Registration# CCC1328417 E-Mail luq®taolockroormg.cean
Architect Name&Phone#
Engineer's Name&Phone#
Workers Compensation Insurer FRSA OR Exempt O Expiration Oate 7020
Application is hereby made to obtain a permit to do the work and installations as Indicated.I certify that no work or Installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT:I certify that all the foregoing information Is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
REC(aRf,)1 U NOTICE OF COMMENCEMENT.
(Signature of Owner or Agent)
(Signature o(Contractor)
Signed and sworn to(or affirmed)before me this a y day of Signed and sworn to(or affirmed)before me this day of
�+ Zo19 T .0 - ., 700 b ,
(SWI kof Notary) (Sign reofnotiry)
( ]P$rwnally Known OR [[ )Personally Known OR
I Vmduced ldemification (°Produced ldemihcation
Type of Identification: _ X)L_ T ��.
ype of Idennficadon.
ADYLBRANTLEY JUDYL BRIWItEy
1 CanmlFdm JGG23f9M CwnmsdmJGG243881
? J FxpgroJury 3L7021 i Expires Jury 31,2022
6xdH ltru Te%Hn Munn NPHHOIF 'il+•wn•• 9mAN ihuiwy Farthapaa9WiBS1019
Recorded 05/14/2019 08:26 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY
RECORDING $10.00
Permit No .. ._. ._
rax Felio No. 170626-0000
NOTICE OF COMMENCEMENT
State of FLORIDA Duval
Countyo!
The undersigned hereby gives notice that improvement wilt be made to certain mat PmPertY,and In accordance
whth Chapter 713,Florida Statutes, the following information Is provided in thm Notice of Commencement.
1. Oesonpi ton GAL poEf 5prroperty:
10-1821Q529E.067 SALTAIR SEC3 NLY 25"L076%
STREETAOORESS:
GLIA ST Agantic Beath FL
7. General descrlPNan of Imprbvemenc Rewool
3 Owner mlormatlon or Lessee informatlon N Lessee contracted Nor the Imppvemen4
a. Name and address: KERR MIC KERR VALERIA OONZALES _
11 19 PERREGRINE OIR E JACKSONVILLE.FL J22ag-".
b. Interest in property:
C. Name and address of fee simple udeho(der(If different from Owner listed abowe):
4. a. Contractor: TADLOCK ROOFING,INC.. 502 CAPITAL CIRCLE SE,UNIT CA,TALLAHASSEE,FL NMI
h. Contractor's phone number:$50.977-5516.
5. Surety(If apialkable,a copy of the payment bond Is attached):
a. Name arld address:
Is. Ph..Nanber
C. Amount of bond: S
6. a. Leber:
b. Lender's phone number:
7. Persons within the State of Florida designated by Owner upon whom routes or other documents may be served
as provided by Seaton 70.1311 Ra)7„Florida Statutes:
a. Name and address: _
b. None numbers of deslgnacea persons: _--
a. A. In Walloon to himself or nerselr o,mr designates
of _ _ to receive a copy of the Uenor's Nutitae as
provided in Section 713.13(t)(b),Florida Statutes.
b. Ploare,number of person or ability dosEnated by owner.
9. LVir&Uw date of node of commencement(the"ndm date will be 1 year trom tM date of recording
unless a different date is spedfied)
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1,SECTION 711.1 T
FLORIDA STATUTE$,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A
NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCNIG, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
COMMEN tliG WORK OB REC RDING YOUR NOTICE OF COMMENCEMENT.
i
(Signature of Owner 6r Lessee,or Owner's a Lessee's Authorixed Office(/DirecturI Partner/
Manages) (Signatory's Title/Office)
The fartgQlns Imt(u�mens 3vas uNnow(edged before me this�$L day of rnT y_ , Z0141
Dye h.Jl V1 a. r
az�w�JYvf -1s) for
� L
1 awre0 tory PUOUC• SW
Ily n_ OR ltd IdlntUKAtbn
'type of Iden'IF, Produced VL—. :y;�^.".<w /udT'4 BRA1102
0Nn^AtOn31,2M BN
te�7F�Q
Nr IntaaN-RppN
r m „ � r4 ) I ! [ a
t ° { ; Q ; \ r
� � . 2 / �f ± k ?
\ Rk = a ! lis I . 05RW, in
= k , .
& t , l � 3No 3 ! » £ a ! ” 3 � za , !
_ ! § 2 %\ 0 { 7
§
0 , ! � k
■ . _ _` � §
» ^ �
-. ^ z
00 }
& - ■ Q §
| , m
§
1p
| { }\ @ §
` ° 2 g
E M \% c !
' M3 ! \
| } [MM
( ! ;
!
k \ a
B
am ( $
f � 3
\ ( Z )
V O O� U O W N N C t0 00 V O� N A Z Ap m
A A V! W y, C n Gl G1 f1 » m N
O O W 0 7 0 2 T .T ! A N d O N 7j C m
Ra $ 3 � 8 T 3
o n
ir 3 n � ' a •'• F 'E'
tag—
s
jp
83
ca
O
3
h
C
N
a �
P ,
e F
a
0
3
m
0
0
3,
c
fN
a
gXg
3 �
E
a
. ter § ; pP ; �o | 2 ) ` - � � N \ 0 § ( � � ' �
F5 ,, 8 § z
� � ; , ru—
� § , + _ \ ; � ¥ ! ! ' � � � ■ , , — .
§ ■ m — � |
; ' !
|
�
■
J
■
$
k
¢
!
k
\ t
. - § \ ( ( ( A } ( �
_ ; £ }
( | 7 { 3 _ - ! 2 !
Ir !
( \
2 7 / 2
& e 3 o
z- 0
F a ! !
m � � �
> ;
Ir
7 f ( k \ k (
m 31
_ :
51 ■ :
� \ } /\
\ 7 E
M.�}
\ ) �
\ \ }\
� / }}
EXTERIOR RESEARCH&DESIGN,LLC.
( Certipcore o/AutMrimtias 49503
\ TRINITY ERD 353 CHRISTIAN OXFORD,Cr 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-Rg
One Owens Corning Parkway FL10674R33
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the fid Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.11 R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report Is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Cade Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through B.
Prepared by: an........
, 'b", me recsinve:esi appeann mm:m by Ruben
Robert J.M.Nieminen,P.E. e•,` e•'ae au
Florid.Reyetmtion No.59166,Rondo OCA ANE103 ��"'^^^"°• Nkminen,P.E.on 10Ma/2017.Thu does not serve as an
e ent—a-i p trained document
CENrmunaN OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is notowned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued,
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the 6w Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prose Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL LUC(CER9626) Physicals&Wind Resistance File R2453,V.I.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LUC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9618) Wind Resistance 11CA34308 02/18/2012
UL LUC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER3592) FBC HVHZ Compliance Various NOAS Various
UL LLC IQUA9625) Quality Control Service Confirmation Eap.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire-are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition Duration*, Duration Premium Cool, TruDefnition Duration Designer Color
Collection, TruDefnition Oakridge, Oakridge and WeatherGuard HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire Hip& Ridge Shingles, High Ridge,WeatherGuard HP Hip& Ridge Shingles, ProEdge Hip &Ridge
Shingles and Dura Ridge'"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMMATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer t0 current Approved Roofing Materials Directory
for fire ratings of this product.
Estero Research and Design,U.C. Evalya0on Report 037L0.02.12-RB
cmlfkmea,,A o,4atwH 6s"EDITION(2017)FBC NON-HVHZ EVALUATION FL3067LR13
Owens Coning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
CJ I MNITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM 0715B,Class H,indicating the shingles are acceptable
for use in all wind zones up to V„d = 150 mph (V„R = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Coming hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for use in all wind zones up to V,:d=150 mph(V"p=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2A or R905.2.3.
6.2 Asphalt Slhmdes:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle.
➢ WeatherGuard HP shingles require minimum six(6)nails per shingle.
➢ Devonshire"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 Or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
FsY.delw�w pari ti W.arerx ow sr.u..x
s.s.ddd W��;
n.rn»m
w..n.teae
e4e um.dse �
beNfeEa6pp Sa.r�rMse YUYb[wrubM rM�MN.eww
aHn�erM6 VauM�,e vMaf�nwN. AWnrt Mwn
6--M aurin sv4+6MkorMUM.earn ad nYn'," 'Y Uewr^V rleaNwA.nwti,ww n,"-y4
E tEnw RC3ea,ph and Oezlgn,LLC. Evaluation Report 037940.W.1LRg
Cert#kxxeo)Aulbw4tr 83303 6"EDITION(2017)F8C NON HVHI EVALUATION FL30674-R13
Owens Coming Asphah Roos Shingles Revision 8:10/09/2017
Page 3&8
TRINITY ERD
6.2.6 Minimum Nailing—Classic•&Supreme:
Nernr Y.w�w ,w BwB rv�,n.i mens..e o. A—Per.
kar MBx ny.knr wwvrxr w,na A,... q96 wmaM.,wy
MBrn.ywx nBnn.I.. .yx. H.wx llxw. Arx p...ri.nsx mub. Iw
JI
IN la W .a T• ]. .• T
I
aYa'E.
'�yy Eipos sNn
6.2.7 Minimum Nailing—Berkshire°:
YfawwYY 4d.ir.a
BW BV! eN' 1wn FW EW
Standard Fastening Pattern 6-Nail Fastening Pattern
arw.olp
4k.6fWr
BW BW BW BW
1•
:i
r A+MR.rvnmemmml
cwwwrYrorarl.m
Mansard or Steep Slope Fastening Pattern
Even.,Research and Design,LLC. Evalu.tlan Report 037980.02.12-112
Cerrykote ojAutawlMkn N9503 6T"EOITION 120171 Fat NON-HVH2 EVALUATION FL10670.R13
Owens Coming Asph.k Raaf Shingle. Renswn W.10/09/2017
P.ge 8 of a
TRINITY ERD
6.2.8 Minimum Nailing–Devonshire^':
8" 8' _ T �..
o..e I—
'— Nass
Silrnporva s.dani brarion _..
fipoeitlbn dFS ilB W4 Mind.de1.1mor
Tei l' d Rod Gnag
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration•, TruDefinitione Duration, Duration• Premium Cool & TruDefinition
Duration Designer Color Collection:
a.x.n Fewnxy rwLwn wwi FaNngq Pagwn
wa9P �.nFd
,. �>• Q !.
JII�__ITLF I
Standard Fastening Pattern 6-Nail Fastening Pattern
faaYnglaaiaa�W Twwiian 12
rwgY
ll��L111 �1'Y,4eV��.
Mansard or Steep Slope Fastening Pattern
Eiderlw Research and Design.LLC. Ewluaeon Report 03N .02.13-Rg
[MykoNplquXwtlaargn ygSpa 6'"EDmON NODI FRC NON-HVH2 EVAWATON FL3067"13
Owens Coming Auphan goof Shingles Revision8:10/09/2013
Page 5 of 8
UTRINITY ERD
6.2.1 Minimum Nailing–TruDeNnition Oakridge°,Oakridge•:
1 Nal M. 6Nall Pa m
EW.R ant Wlpa cs9P.a an6daoa
1-
II��yi' 4 —M h— 4—N
55K EquuE 6FT6apPln
Erpdtl6W6NpIg p EQetl6M666rtpIp 66I6'Npaue c4✓or 66R Fvpw
fpmmnJe 55/epW4 Egov[gnW 56///Jp
Standard Fastening Pattern 6-Nall Fastening Pattern
i�YnIMMYynWYTM
in I.
w„Y•�wewa•ti e��
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard•HP:
g. t FnaM FIM 41Mw
p..r�
Exterior Research and Di,0Rn,I.I.C. E ralwtion Report 0319410.02.12-118
CMgf gAurXwtrot...3 6"EDITION(2017)FRC NON-HVH2 EVALUATION F1.10610.1133
Owens Corning Asphalt Roof Shingles Revivan 9:10/090011
Page fi of e
TRINITY ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of OuraRidge^ Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
63.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FRC
1502.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire'Hip&Ridge and High Ridge:
FIa1 FaR
�— va v Mw
♦
L i ♦ � ii
I tr —a�
6.3.4 Minimum Nailing—WeatherGuard•HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fgabdlg
Fig.A Fr r=ev.,
eas
YY —i4�
I��` e±. ♦ I
1
Exterior Research and Design,U.C. Evaluation Repan 0US40.0Z.12-10I
[ertakore nJRulM1ortrotlon n503 6-EOMON IZe17I FOC NON-HVHZ EVAWA110N FL10674R13
Owens coming Asphalt Rood Shingles Revision 8:10109/2013
Page 7 0 8
TRINITY ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard ^tl'
Wind rDirection
Fast
Sdant Strip P.nen.ning
8'Eryem
O17
:- rr �r
1 Sa41get
FertW 7'h' 71' t
Yflg
F�E�seWnhadh
Raaf Dons
6.3.6 Minimum Nailing—DuraRidgen'Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
wee I'
os.rwd4dwlara�
-
�� I7 I
I i iS
I I i i r B18B
iPISSSS
IT�
7. LIBELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.1.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALM ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Eaterior Research and Design,LLC Evaluation Report 037940.02.12-118
[eolsooe q.."areutbn H503 6r"EDITION(Z017)FBC NON-HVHZ EVALUATION FL1067CR33
Owens Coming Asphaft Roof Shingles Revision 8:10/09/2017
Page a of 8
M® MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(986)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.m mddxde.aov/eeoaomv
Owens Corning Roofing and Asphalt,LLC.
One Owers Corning Parkway
Toledo,OH.43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHD).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ my immediately revoke,modify,or suspend the use
of such product or material within theirjurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ProArmorTm Synthetic Roof Underlayment
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there bas been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,than it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at thejob site at the request of the Building Official.
This NOA revises NOA# 14-1215.05 and consists of pages 1 through 3.
The submitted documentation was reviewed by Alex Tigers.
ANOA No.: 17-0124.02
MIAMI-oA®uN+ Expiration Date: 11/1220
Approval Date: 0125/36
Page 1 of 3
ROOFING COMPONENT APPROVAL
Cateeorv: Roofing
Sub-Cateeorv: Underlayment
Material: Polyolefin
SCOPE:
This approves ProArmorTai Synthetic Roof Underlayment, as described in this Notice of Acceptance; designed to
comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
Test Product
Product Dimensions Specification Description
ProArmorTai Synthetic 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment coated with
Roof Underlayment 25 lbs.per roll Type II UV protected and slip resistant polymer stabilized
polyolefin.
MANUFACTURING LOCATION:
1. M.L.#1
EVIDENCE SUBMITTED:
Test Aeencv Test Identifier Teat Name/Reno rt Date
Intertek Testing Services NA LTD 102783795COQ-004 ASTM D 226 11/11/16
INSTALLATION SPECIFICATIONS: (Single Layer: Slopes of 2:12 or greater)
1. ProMnoroa Synthetic Roof Underlayment shall be installed in strict compliance with applicable Building
Code.
2. ProArmorT Synthetic Roof Undedayment shall be installed with a minimum 4-inch horizontal lap and 6-inch
vertical laps in a shingle layer fashion. Vertical laps in a succeeding course shall be staggered from those in
preceding course by mirtimum 64eet.
3. PmArmorTm Synthetic Roof Underlayment shall be fastened with approved roofing nails and tin-caps spaced
6"o.c.at all laps and three staggered rows fastened 12"o.c.in the field of the roll.
4. ProArmorTM Synthetic Roof Underlayment may be used with Asphaltic shingles,Wood shakes and shingles,
Non-structural metal roofing,and quarry slate.
5. For fire classification of speck roof assemblies using ProArmorT- Synthetic Roof Underlayment refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
NOA No.: 17-0124.02
HnnF r atiNrY Expiration Date: 11/12/20
Approval Date: 01/25/18
Page 2 of 3
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITAnoNs:
1. Fire classification is not part of this acceptance;refer in a current Approved Roofing Materials Dvectory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. ProArmorT Synthetic Roof Underlayment shall be applied to a smooth,clean and dry surface with deck free of
irregularities.All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking
panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
4, ProMnorT^'Synthetic Roof Underlayment shall not be hot mopped,refer to manufacturer's published literature
for product compatibility.
5, ProMmorT-Synthetic Roof Underlayment shall not be applied over an existing roof membrane as a recover
system.
6. PmArmorTm Synthetic Roof Underlayment shall not be left exposed as a temporary roof for longer than 90 days
of application.
7, ProArtruim Synthetic Roof Unde dayment are components used in roof system assemblies.Roof system
assemblies are approved under a specific Notice of Acceptance.Refer to Prepared Roofing system Product
Control Notice of Acceptance for listed approval of this product with specific prepared roofing products.
8, ProArmorTm Synthetic Roof Underlayment may be used with any approved roof covering Notice of Acceptance
listing PmArmur" Synthetic Roof Underlayment as a component part of an assembly in the Notice of
Acceptance. If PmArmofrm Synthetic Roof Underlaymem are not listed,a request may be made to the
Authority Having Jurisdiction(AHI)or the Miami-Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products,wind uplift
resistance,and fire testing results.
9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacnmer's name or logo,
city,state and the following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade
County Product Control Seal m shown below.
twsmamactxwrrT
END OF THIS ACCEPTANCE
NOA No.: 17-0124.02
nwroaoma eourm Expiration Date: 11/12/20
' Approval Date: 01/25/18
Page 3 of 3
Mr�IAM!� MIAMI-DADE COUNTY
0mI PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2494
T(796)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www mmmidaae.rov/eroaamv
Owens Corning
1 Owens Coming Parkway
Toledo,OR 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend theme of such product or material within theirjurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:VentSure Ridge Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA#07-0125.01 and consists of pages l through 4.
The submitted documentation was reviewed by Alex Tigera.
�,/� NOA No.: 12-0309.02
niAnlmwoecoul4Tr �Jlljrf'l'( Expiration Date: 10/31/13
®' Approval Date: 10/18/12
Page 1 o(4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Ventilation
Material: Plastic
Minimum Slope: 3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product Dimensions Test Product
Specification Description
Vent Sure Ridge Vent 11'''A"wide, TAS 100(A) Ridge ventilation system.
5/8"high,
lenths of 4' &8'
Vent Sure Rigid Roll I1'h"wide, TAS 100(A) Ridge ventilation system.
5/8"high,
lenths of 20'&50'
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test Product
Product Dimensions Specification Description Manufacturer
Asphalt Roof Cement ASTM D 4586 Asbestos-free,asphalt based Generic
roof cement.
Asphalt Primer ASTM D 41 Asphalt Primer Generic
Roofing Nails Minimum# 12 TAS 114 Corrosion resistant annular ring Generic
shank nails
Sheet Metal Screws Minimum 910 TAS 114 Sheet metal screw generic
MANUFACTURING LOCATION
1. Baldwyn,MS
EVIDENCE SUBMITTED
Teat Aeeuev/Identifter Name Report Date
Omega Point Laboratories,Inc. ASTM D 1929-91 163332-109020 06/11/01
ASTM D635 163332-109022 06/11/01
ASTM D 2843 163332-109021 07/11/01
Architectual Testing Inc. TAS 100(A) 01-38660.04 04/25/01
Architectual Testing Inc. TAS 100(A) 01-38660.05 04/25/01
NOA No.: 12-0309.02
niAWDAor COUNTY Expiration Date: 10/31/13
Approval Date: 10/18/12
Page 2 of 4
APPROVED APPLICATIONS
Tradename: Vent Sure Ridge Vent R.Vent Sure Rigid Roll
System Type: Mechanical attachment of ridge vent system over composition shingles.
Cutout:
1. Determine whether the rafters are truss or ridgepole
construction. Cut sheathing 2"(truss)or 3-1/2"(ridge
pole)wide slot(1"truss or 1-3/4"ridge pole on each side)
' of the ridge(s). A minimum of 6"must be left uncut on
each end of the ridge. Once the slot is cut and any
overlapping shingles covering the ridge are trimmed and
removed,the ridge is ready for vent installation.
Installation:
2. Place the Vent Sure Ridge Vent or Vent Sure Rigid
Roll vent,routed side down along entire length of slot also
covering the 6"minimum uncut ridge on both ends.
Multiple lengths of vent can be joined by butting them
together.
3. Pull apart a 3"or 5-1/4"precut section of the foam endcap.
r Using construction adhesive or sealant caulk,insert the
-p endcap into the end of the vent. Using four(4)2"
F galvanized roofing nails,attach vent to the roof deck by
driving a nail in each of the two comers on both ends of the
vent,and a nail at each side through the foam cap.
4. After vent has been installed,cut ridge shingles,preform,
and nail with roofing nails in a common overlapping
pattern. Nails should be approximately 5"apart and long
enough to penetrate the wood roof deck at least%". Repeat
this procedure until vents have been installed over all roof
j \\` ridges.
Net Free Area: Refer to manufacturers published literature
LIMITATIONS:
1. Refer to applicable Building Code required ventilation.
2. Ridge Vent shall comply with applicable Building Code.
3. Ridge Vent shall not be installed on roof mean heights greater than 33 feet.
NOA No.: 12-0309.02
MIAMI RADE COUNT Expiration Date: 10/31/13
1= Approval Date: 10/19/12
Page 3 of 4
DETAIL A
VENT SURE RIDGE ROLL
AND
VENT SURE RIGID ROLL
4,8,20 .50/
11.2
an
L
----------
END
--END OF THIS ACCEPTANCE
NOA No.: 12-0309.01
MIAMIDPDECOUNTY Expiration Dale: 10/31/13
4f Approval Date: 10/10/12