Loading...
1222 Jasmine St ROW19-0014 relocate streetlight permit RIGHT OF WAY PERMIT PERMIT NUMBER ROW19-0014 CITY OF ATLANTIC BEACH ISSUED: 5/22/2019 800 SEMINOLE ROAD ATLANTIC BEACH. FIL 32233 EXPIRES: 8/20/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1222 JASMINE ST RIGHT OF WAY SINGLE OR TWO relocate street light $0.00 FAMILY RIGHT OF WAY TYPE OF REALESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 1710200005 ATLANTIC BEACH SEC H —7 COMPANY: ADDRESS: CITY: STATE: ZIP: Jacksonville Electric 21 W. Church Street Jackonville FL 32202 Authority OWNER: ADDRESS: CITY: STATE: ZIP: BROOKS CHRISTY 1222 JASMINE ST ATLANTIC BEACH FL 32233-1819 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. I PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. Issued Date: 5/22/2019 1 of 2 RIGHT OF WAY PERMIT PERMIT NUMBER ROW19-0014 ATLANTIC BEACH CITY OF 800 SEMINOLE ROAD ISSUED: 5/22/2019 EXPIRES: 8/20/2019 ATLANTIC BEACH, FL 32233 3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way. 4 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIE S -7 INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. 5 1 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT LTOTAL: Issued Date:5/22/2019 2 of 2 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 fCLJ Iq - 00 iLf Phone(904)247-5826 - Fax(904)247-5845 0)1 H E-mail: building-dept@coab.us IL Date routed: Cityweb-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Department review required Yes -No Building Applicant: Planning &Zoning Tree Administrator Project: GW(AtL -- -rkJA �ij�lk <-Public 4-Public Utilmfips_�1 Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: VApproved. [-]Denied. [:]Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING TREE ADMIN. Reviewed by_�,fK4 Date. Second Review: DApproved as revised. ElDenied. F]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: E]Approved as revised. UlDenied. E]Not applicable Comments: Reviewed by: Date: Revised 05/1912017 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road tlantic Beach, Florida 32233-5445 9-ow t q — 00 1 L( Phone(904)247-5826 - Fax(904)247-5845 UM E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us 11 APPLICATION REVIEW AND TRACKING FORM Property Address: Department review required Yes -No Building Applicant: Planning &Zoning Tree Administrator Pro ect: tw Cat L a Ckublic zo Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLIC4T40N STATUS Reviewing Department First Review: 5e<pprovecl. ElDenied. E]Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b : ZJ- Date: ot TREE ADMIN. Second Review: E]Approved as revised. FIDenied. []Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: EjApproved as revised. []Denied. E]Not applicable Comments: Reviewed by: Date: Revised 05/1912017 PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: 5115 [lei Application#: Kov) lfl- ool � Project Address: 12z'z jo�sr,(\ Inn Check Box Check APPLICATION TRACKING COMMENTS to Add Box to Comment Print Underground Avoid damage to underground water and sewer utilities. Verify vertical and Water Sewer horizontal location of utilities. Hand dig if necessary. If field coordination is 1!r' Utilities needed, call 247-5878. Meter Boxes Ensure all meter boxes, sewer cleanouts and valve covers are set to grade Sewer Cleanout and visible. 0 13 A sewer cleanout must be installed at the property line. Cleanout must be RT1 Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade 0 0 Cleanout and visible. A reduced pressure zone backflow preventer must be installed if irrigation will RPZ be provided or if there is a private well on the property. Backflow preventer 0 0 Backflow must be tested by a certified tester and a copy of the results sent to Public Utilities. Plans note the building will be unsprinkled. If plans change, any fire line Sensus installed must be metered with a Sensus touch-read meter in a properly sized Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer 0 13 Meter must be tested by a certified tester and a copy of the results sent to Public Utilities. Fire Sprinkler If fire sprinkler system is provided, call 247-5878 for backflow requirements. Backflow 0 Requirement At a minimum,will require a double check backflow preventer. Fire Line Fire lines must be metered with a Sensus touch-read meter. Meters larger 0 0 Meter than 2" must be installed in a vault as noted in JEA specifications. Utility Map See attached Utility Map. B`_ Disconnect &Cap Disconnect and cap water and sewer lines. 0 0 Inspection Must call the Inspection Line at 247-5814 to request an inspection of the Prior disconnected and capped water and sewer lines prior to demolition. 13 0 0 0 0 0 0 0 0 RIGHT-OF-WAY EASEMENT PERMIT APPLICATION "ALL INFORMATION City of Atlantic Beach HIGHLIGHTED IN GRAY IS 800 Seminole Road,Atlantic Beach,FL 32233 REQUIRED. 9' PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address I ZZ JP-3 v-j-?.,P7 e- Permit Number 01 Contractor Information Company--7� Qualifying Agent Address ZI &41W-elA Cit 7-Ax State--Pl —zip a Phone Email State Ce rtification/Reg ist ration# Architect Phone Email Engineer St Phone 9 9!9 3 E m a i 1 Workers Compensation lnsurei^F�/] OR ExemptnExpiration Date • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation,alteration or relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles, wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of (Project Superintendent) with(Company Name) Phone (26s-- n�--3 0 All materials and equipment shall be subject to inspection by the Public Works Director. 0 All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. 0 A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. 0 The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. 0 It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. e notified 24 hours prior to starting work and again immediately upon completion. Date S - .2- 12 Permittee(signed in presence of Kotar'y Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of 20_ by who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. [ ]Personally Known Signature of Notary Public,State of Florida Produced Identification(Type) H:\Applications&Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date:10/1/18 ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:38470 N.O.: 8005212 WO#: 30431656 CONST 05107119 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O,: 561 REQ'D:NO CELL ENQINEER:Robert Simpson N.o.: NIA ZIP CODE: N/A CUSTOMER/' - Svc PHONE LOCATION: 1222 JASMINE STJ 45/3W REPLACEMENT 561 CENTER: SSSC N.O,:665-7793 1426 2 rq 'NJ M 0 STA 1, P# 1222 JASMINE STJ R&R 45/3W, 50KVA, RELOCATE STREET 1430 , LIGHT. RELOCATE UG SECONDARY 1418 Al \10 25A 2 53TA SERVICE. CONVERT OH SHIELD TO F-,,.-' a CD NEUTRAL TO STA 2. 1 0 --Z STA 2, P# 1325 JASMINE ST. 14TH ST W —9uu 7-77 'k". i 30T :A:� A, < 1/OT 1/OT c 2T 00 1 T 720 Pv 850 820 1 750 1382 25A STA 2 0 kn 00 rSl�3 2 25A 1350 kn tn j 50A \�c t-- U) Z w z 'I 1270 kn W) 40P mlw 25A kf) kn It Itt I rq cl STA I lq* 4 131171S 1 0 Lj mm rkn STA lk 25A W) 0. —N rq 0 �,c F- 50A 40. 1203 AD, 25A N CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWOft/Task:30431656 Required Date: Oracfe Project#:8005212 Estimated On: 05107/2019 CU Detail Station: 01 1.22 AWNE Build Transfer Remain in Place Remove C.2 250 DA5F-5*2 1 DGAC*50 I G3W*2 1 GY3-A*5 1 HANDDIG 5 P.45/3W 1 RUBLIP 4 S20ES*2/0-1/0 4 S4*4/0 2 S5*2 1 S9*1/0 4 S9*2 2 S9*2/0 2 SRISERSMALL 2 ANCHOR 1 ARRESTER 1 BANK10 1 BAYONET 1 C.2 250 CLAMP 1 CUT 3 CUTOUT I DESHOE 2 DEYE 2 DOWN3/8 I EYENUT 2 FULLGRD 1 GUARD 1 LUM7 I NUMBER I P.45/3W 1 PIN 1 POLECON 3 PRIINS 1 CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWO#/Task:30431656 Required Date: Oracle Project#:8005212 Estimated On: 05/07/2019 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $933.22 $933.22 2.Transformer Cost(w/sales tax) $1,408.98 $1,408,98 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $3.647.37 $2,676.19 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(43.52%of lines 4&7) $1,800.99 $156.77 7.Engineering Costs(Variable%of line 4) $490.94 $360.22 8.Project Equipment Costs(40%of total equipment costs) $2,166.95 $0.00 9.Material Handling(6.67%of lines 1 &2) $156.22 $156.22 10.Inspection(6.84%of line 4) $0.00 $183.05 11.Total Cost of Project $10,604.67 $5,874.65 12.Work Order Estimate(Line 11 minus line 8,9,&10) $8,281.49 $5,718.42 13.Billable Equipment Depreciation(60%of total equipment costs) $3,250.43 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11 +13+(64.49%of 4&7)) $16.523.89 $6,106.95 15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(64.49%of 4&7)-Line 2) $15.114.91 $4,697.97 Time Estimate Crew Hours Total Manhours 29.24 116.98 ----------------------------------------------------------------------------------------------------------------------------------- CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SIR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWO#/Task:30431656 Required Date: Oracle Project#:8005212 Estimated On: 05/07/2019 Conductor, Conduit and Pipe Detail Quantities From Station To Station cu Build Transfer Remain Remove 01 2 C.2 0 0 0 250 01 2 C.2 250 0 0 0 CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SIR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWO#/Task:30431656 Required Date: Oracle Project#:8005212 Estimated On: 05/07/2019 RUBDOWN 4 SEC 2 SECINS 2 SMWEDGE 3 STANDOFF 1 SWITCH 1 TANGENT 2 Ll Station: 2 1325 JASMINE ST. Build Transfer Remain In Place Remove DA6-6*2 I RUBUIP 4 S5*2 1 S9*2 2 BAYONET RUBDOWN 4 CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWO#[Task:30431656 Required Date: Oracle Project#:8005212 Estimated On: 05/07/2019 1 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE TO GROUND, 100A,27 KV. 170 KVBIL (54EAPERPALLET) 1 FUSOH024 FUSE, OVERHEAD DISTRIBUTION,3.1 AMP, TRANSFORMER. 1 GRIPRO01 GRIP, PREFORMED, 3#6AW, 22", DEADEND I GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 1 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8% POLYETHYLENE, USED ON ALL 3/8"AND 7/16" GUY STRANDS (DISTRIBUTION) 1 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT. STRENGTH. FOR WOOD OR CONCRETE POLES 2 GUYGRO01 GRIP, GUY,3/8", 26", GALVANIZED 50 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B" GALV. OR BEZINOL IS ACCEPTABLE (500-COIL) 1 INSCO001 INSULATOR, COMPOSITE,SILICON-RUBBER,LEAKAGE DISTANCE MIN. 36", MIN. 25KV, 15000#STRENGTH, DEADEND 1 INSFE002 INSULATOR, FIBERGLASS EXTENSION REMARKS:FIBERGLASS W/PROTECTIVE COATING CLEVIS-EYE, 12 INCH FIBERGLASS LENGTH, 15,000 LB ULTIMATE STRENGTH USED FOR EXTENDING POLYMER DEADEND INS. FROM POLE 1 INSGBOO2 INSULATOR, STRAIN, GUY BREAKER,21,000#RATED, 60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 2 INSSU002 INSULATOR, SUSPENSION, 4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 1 NUTEY002 NUT, EYE, 5/8", HOT DIPPED GALVANIZED 1 NUTEY003 NUT, EYE, 3/4", HOT DIPPED GALVANIZED 2 NUTSI-003 NUT, LOCK, SQUARE,5/8" HOLE SIZE, HOT DIPPED GALVANIZED 4 NUTSI-004 NUT, LOCK, SQUARE, 3/4" BOLT SIZE, HOT DIPPED GALVANIZED I POLWO006 POLE,WOOD,45- CLASS 3 (T/L=26),WEIGHT=1,770 LBS 1 RODGRO03 ROD, GROUND, THREADLESS,5/8"X 8% SHIP ON OPEN FLATBED ONLY! 4 SLEAL002 SLEEVE, ORANGE TO ORANGE NEUTRAL 4-4 ALUMINUM TRIPLEX NEUTRAL SPLICING 4 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL SPLICING 2 SLEFT004 SLEEVE, 2/0, FULL-TENSION ALUMINUM COMPRESSION TYPE I TAGH0007 ALUMINUM VERTICAL TAG.HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 1 THIEY001 THIMBLEYELET, 3/4",.MALLEABLE IRON, HOT DIPPED, GALVANIZED, ***STD PKG 25 EACH ` 1 TRAC0002 TRANSFORMER, 50 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT SECONDARY, SINGLE PHASE, CONTAMINATED ENVIRONMENT-JEA SPECIFICATION REQUIRED 2 WASRD004 WASHER, ROUND, 5/8" BOLT SIZE X 1 3/4"DIAMETER, GALVANIZED, 650 EA P/BOX) 14 WASRD005 WASHER, ROUND, 3/4" BOLT SIZE X 2" DIAMETER, GALVANIZED, 500 EACH PER BOX*** CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRI3 MWO#/Task:30431656 Required Date: Oracle Project#:8005212 Estimated On: 05/07/2019 Material Summary Item Quantity Item Number Item Description 1 ARRL1003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER POLE (MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL VOLTAGE 1 BAYSWO03 BAYONET, SHIELD WIRE, CORNER,40"LENGTH 1 BKTAC009 BRACKET, ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM MATERIAL OVER ROD TYPE: SINGLE PHASE 1 BOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV.WITH 4 SQUARE NUTS ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 1 BOLEY005 BOLT, EYE, 5/8"X 16", GALVANIZED, WITH SQUARE NUT ATTACHED 2 BOLMS020 BOLT, MACHINE, 5/8"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 50 EACH) 1 BOLMS032 BOLT, MACHINE, 3/4"X 6", SQUARE HEAD GALVANIZED STE-EL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 50 EACH) 3 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED�_T_EEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 3 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED�T_EEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 1 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 4 CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:#6-2/0 4 CLASS004 CLAMP, STRAIGHT STRAIN, ALUMINUM, 5000#,4-3/0 ALUM 2 C[A-SS006 CLAMP, STRAIGHT STRAIN,ALUMINUM, 10000ft 3/0-556 ALUM�S_TD PKG 15 EA) 1 CLATGO01 CLAMP,TRANSFORMER TANK GROUND, "BRONZE"6 SOL - 1 §TR- 15 CNNCP002 CONNECTOR,#2, 6-2 IMAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 20 CNNCP004 CONNECTOR, #4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 4 CNNCP005 CONNECTOR,#3, 6-2 MAIN, 2/0-3/0 TAP, COMPRESSION, PARALLEL TAP,ALUMINUM, 3 CNNTS009 CONNECTOR, CONTAMINATED ENVIRONMENT,TRANSFORMER SECONDARY SET SCREW TYPE WITH INHIBITOR, 1/2"STUD, RANGE: 12-350, 6-PORTS. 4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE 250 COBAA020 CONDUCTOR, #2 (AAAC), 7 STRAND, BARE ALL-ALUMINUM ALLOY 'AMES" 36 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON PLASTIC REEL,4"X 11.5"W1 2"HOLE 70 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD& COPPERWELD- COPPER.204" DIAMETER 1480#BREAKING STRENGTH (50#COIL- 427') 30 COVIC002 COVER, "D"DIE, INSULATING, 2-1/2" CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWO#[Task:30431656 Required Date: Oracle Project#:8005212 Estimated On: 05107/2019 SEC 2 SEC. SPOOL INS. BRACKET REMOVAL SECINS 2 SEC. INSULATOR REMOVAL SMWEDGE 3 SMALL SEC. WEDGE CLAMP REMOVAL STANDOFF 1 PRI. INSULATOR STANDOFF BRACKET REMOVAL SWITCH 1 CUTOUT&ARRESTER BRKT. REMOVAL TANGENT 2 S7 REMOVAL CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SIR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWO#/Task:30431656 Required Date: Oracle Project#:8005212 Estimated On: 05/07/2019 CU Summary : - 9 CU Name Quantity De3criation C.2 250 #2 AAAC DA5F-5*2 1 DEADEND UNSHIELDED DA6-6*2 1 NEUTRAL TO SHIELD TRANSINTION S-PHASE DGAC*50 1 TRANS; CI, 26AKV 120/240 50KVA G3W*2 1 WOOD POLE-NON-EQUIPMENT GROUND GY3-A*5 1 3/8"DOWNGUY WITHOUT ANCHOR HANDDIG 5 NO DESCRIPTION... P.45/3W 1 45 FT. CLASS 3 WOOD POLE RUBLIP 8 LINE RUBBER INSTALLATION, PER SECT. S20ES*2/0-1/0 4 S20ES*2/0-1/0 S4*4/0 2 SECONDARY DEADEND S5*2 2 NEUTRALDEADEND S9*1/0 4 SECONDARY SPLICE S9*2 4 SECONDARY SPLICE S9*2/0 2 SECONDARY SPLICE SRISERSMALL 2 SECONDARY RISER RELOCATE, 4/0 OR SMALLER � TRANSFER U-NAM Quantity Description Ll 70W HPS ROADWAY FIXTURE LREMOVE Quantity ANCHOR 1 SINGLE-HELIX ANCHOR REMOVAL ARRESTER 1 DIST.ARRESTER REMOVAL BANK10 1 SINGLE TRANS. REMOVAL, UP TO 75KVA BAYONET 2 BAYONET REMOVAL C.2 250 #2 AAAC CLAMP 1 HOT-LINE CLAMP REMOVAL CUT 3 CUT POLE OR CROSSARM CUTOUT I FUSE CUTOUT REMOVAL DESHOE 2 NEUTRAL DEAD-END SHOE REMOVAL DEYE 2 S6 REMOVAL DOWN318 1 3/8 IN. DOWNGUY REMOVAL EYENUT 2 EYENUT REMOVAL FULLGRD I EQUIPMENT GROUND REMOVAL GUARD 1 YELLOW GUY GUARD REMOVAL LUM7 I STREETLIGHT FIXTURE REMOVAL 70W HPS NUMBER 1 POLE TAG REMOVAL P.45/3W 1 45 FT. CLASS 3 WOOD POLE PIN 1 INSULATOR PIN REMOVAL POLECON 3 S20 REMOVAL PRIINS 1 PRIMARY INSULATOR REMOVAL RUBDOWN 8 LINE RUBBER REMOVAL, PER SECT. CUE Reports Estimate Number:38470 1222 JASMINE STJ 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMET Estimate Version: By: SIMPRB MWO#tTask:30431656 Required Date: Oracle Project#:8005212 Estimated On: 0510712019 10 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 5/8"X 3/4"BOLT SIZE, GALVANIZED 6 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) N, . ............ ----------- s 14 17, m Irk, IL 4`1 AX,, -Rip At, 10A