Loading...
1638 Maritime Oak Dr Leakage Test Report FLORIDA ENERGY EFFICIENCY CODE . FOR BUILDING CONSTRUCTION Envelope Leakage Test Report p Prescriptive and Performance Method Prajed Naox,Rt)0n+.r- 6e"4 ' C.(„ Builder Name.Tol) 8r,}ners Street 1(t}fMK,,FTC N7 < De. permit Number: City,State,Clp Permit Design Lomill Afl m.+.9K. �C)'1p1 t J'j 3ZZ33 Junsdidion'. Cond.Floor Area:: Cond.Volume: 3p81 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: o._ R. CFM(50): 2555 Single Point Test Data: ELA. HOUSE PRESSURE FLOW: - t 50.0 EgLA: 2 Not Applicable Not Applicable ACH: 3 Not Applicable Not Applicable ACH(50): 4 Not Applicable Not Applicable SLA'. 5 Not Applicable Not Applicable 6 Not Applicable Not Applicable • R402A.1.2 Testing.The building or dwelling unit sham be tested and verified as having an air leakage rate of not exceeuing 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in climate Zones 3 through 8.Testing shall W conducted with a blower door at a pressure of 0.2 undies w.g.15o Pasralel.Where required by the code official,testing shall W conducted by an approved third paM.A written report of the results of the test sham be signed by the party conducting the test and provided to me code official.Testing shall be perfmmed at any time after creation of all penetrefions of the building themnal envelope. During testing: 1.Exteriorwindows and doom,fireplace and stove doors shall he dosed,but not reeled,beyond dire intended weathersMpping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdmft and flue dampers shall be dosed,but not sealed beyond intended intimation control measures; 3.Interior doom.if installed at the lime of the test,shall be open; 4.Exterior doom for continuous ventilation systems and heat recovery ventilators shall be closed and sashed, 5.Heating and cooling systems,if installed at the time of the test,sham be turned off,and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, 0F2NE STq T� performance results demonstrate compliance testing shall be conducted by an with Florida Energy Code requirements in approved third parry.A written accordance with Section R402.4.1.2, report of the results of the test shall be signed by the third partyos e y conducting the test and provided to SIGNATURE: r� f�f L./ the code official. �,\oU w[SaJ PRINTED NAME:to1 (jr'()�"`) — DATE: 1 BUILDING OFFICIAL:-- DATE: 211620198:01 AM EnergyGauge®USA-F'IaRes2ot4 -Section R405.4.1 Compliant Software Page l oft