735 Amberjack Ln ROOF19-0050 Torch .1'_\i'jlr I
ROOF NON SHINGLE PERMIT PERMIT NUMBER
7- ROOF19-0050
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD ISSUED:
ATLANTIC BEACH. FL 32233 EXPIRES:
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county,and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
735 AMBERJACK LN ROOF NON SHINGLE torch down re-roof $7490.00
TYPE OF REALESTATE BUILDING USE
CONSTRUCTION: NUMBER: ZONING: GROUP: SUBDIVISION:
1711960000 ROYAL PALMS UNIT 01
COMPANY: ADDRESS: CITY: STATE: ZIP.
AFFORDABLE ROOFING 1348 Clements Woods Ln JACKSONVILLE FL 32211
OWNER: ADDRESS: CITY: STATE: ZIP:
WILLIAMS GEORGE LIFE 735 AMBERJACK LN ATLANTIC BEACH FL 32233-4204
ESTATE
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $90.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00
BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.78�
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $189.78
Issued Date: I of 2
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
(904) 247-5800
BUILDING REVIEW COMMENTS
Date: 5/28/2019
Permit#: ROOF19-0050 Site Address: 735 AM BERJACK LN
Review Status: REM 171196 0000
Applicant: AFFORDABLE ROOFING Property Owner: WILLIAMS GEORGE LIFE ESTATE
Email: vmarino2009@gmail.com Email: tinaocasio45@outlook.com
Phone: 9042607663 Phone: 9042280834
9044496339
THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS.
Revisions may not be submitted until ALL departments have completed their respective reviews.
Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a
few correction items will not be accepted.
Correction Comments:
1. Submit 2 copies of the manufacturer's installation instructions for all of the elements of the torch down
roof system and the Evaluation reports for the cap sheet. Please only submit the pages from the report
that pertain to the site specific application on this roof.
Building
Mike Jones
Building Inspector/Plans Examiner
City of Atlantic Beach
800 Seminole Road
Atlantic Beach, FL 32233
(904) 247-5844
Email:nij ones@coab.us
'11412-011 7,�\
Resubmittal Notes:
All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of
completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by
indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date
and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which
a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with
revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left
I City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
800 Seminole Road U-)L
Atlantic Beach, Florida 32233-5445 f7'( tj
V Phone(904)247-5826 - Fax(904)247-5845
ru I it E-mail: building-dept@coab.us L Date routed: IC7
City web-site: hftp://www.coab.us I __ I
APPLICATION REVIEW AND TRACKING FORM
Property Address: PM�nt review required Y 0
(-Euilding
Applicant: -Ffmrtrg_&Zoning
Tree Administrator
Project: Public Works
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ElApproved. Pq-Denied. El Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: D a t e: !�12-
TREE ADMIN.
Second Review: F]Approved as revised. F]Denied. F]Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ElApproved as revised. [:]Denied. FNot applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
ROOF
SuNiag Permit Application
City of Atlantic Beach
800 Seminole Road,Atlantic Beach, FL 32233
Phone: (904) 247-5826 Fax: (904)247-5845
Job Address: 735 AMBERJACK LN Atlantic Beach FL 32233 Permit Number: o o
Legal Description 30-60 17-2S-29E ROYAL PALMS UNIT I LOT 11 BLK 5 RE# 171196-0000
Valuation of Work(Replacement Cost)$ 7,495.00 —Heated/Cooled SIF N/A Non-Heated/Cooled N/A
• Class of Work(Circle one): DIM* A=0(XK XMYX(&X KKUX DOM X)MM IRSMIX 1AXKi(XX*SW new roof
• Use of existing/proposed structure(s)(Circle one): qXM0(X0d Residential
• If an existing structure,is a fire sprinkler system installed?(Circle one): 1606 A%K N/A
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal N/A
Describe in detail the type of work to be performed:
Remove and replace existing roof with new roof per FBC
-T'o rctil, VL aV�3 . I IL L
Florida Product Approval# !+iIig4es+bi83 �. for multiple products use product approval form
PropertV Owner Information
Name: OCASIO,TINA Address: 735AMBERJACKLN
FL 32233-4204 ;'-----228-0834___
City ATLANTIC BEACH State—Zip Phone
E-Mail tinaocasio45@outlook.com
Owner or Agent(if Agent, Power of Attorney or Agency Letter Required) MAY 2 1 2M
Contractor Information
_.___N�
Name of Company: Affordable Roofing Qualifying Agent: VincentMarino
Address 1348 Clements Woods Lane City Jacksonville State FIL Zip 32211
Office Phone 904-260-7663 Job Site/Contact Number 904-449-6339
State Certification/Registration# CCC057697 E-Mail vmarino2009@gmail.com
Architect Name&Phone# N/A
Engineer's Name&Phone# N/A
Workers Compensation Exempt / Leased Employees
Exempt/Insurer/Lease Employees/Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
Ck�
(Signature of Owner kA)(gxw A (Signatu of Contractor)
'Jne r
r affir e fc
_' by ,a ri in
E
L S Aota �U
I Flo gnat,
9
_0(o
Signed and sworn or affir e before me thi day of Signed and sworn to(or aff'. d) before me this day of
10% 7A Y(\Zx�,i 01\_0)01 dv incent Marin
by
A
ALIBREY M.LITTLES AA
A Notary PuNic,State of Flo ida gnature of lVota
No 401 ry)
Comrrission#GG 25957
My oomm.ex0es SW.17,2022 17,2022
My co(w.expires
JVersonally Known OR 1krsonally Known OR
t'l Produced Identifi ti [qProduced Identification
Type of Identification: L 1)L Type of Identification: C-L D
A,"I -� ip- goo elf -CPO
NOTICE OF COMMENCEMENT
State of Florida Tax Folio No. 171196-0000
County of Duval
To Whom It May Concern:
The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of
the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT.
Legal Description of property being improved: 30-60 17-2S-29E ROYAL PALMS UNIT I LOT I I BLK 5
Address of property being improved: 735 AMBERJACK LN Atlantic Beach FL 32233
General description of improvements: new roof
Owner: OCASIO,TINA Address: 735 AMBERJACK LN ATLANTIC BEACH,FL 32233-4204
Owner's interest in site of the improvement: 100
Fee Simple Titleholder(if other than owner): n/a
Name:
Contractor: Affordable Roofing
Address: 1348 Clements Woods Lane Jacksonville,FL 32211
Telephone No.: 260-7663 Fax No:
Surety(if any) n/a
Address: Amount of Bond$
Telephone No: Fax No:
Name and address of any person making a loan for the construction of the improvements
Name: n/a
Address:
Phone No: Fax No:
Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be
served: Name: n/a
Address:
Telephone No: Fax No:
In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section
713.06(2)(b),Florida Statues. (Fill in at Owner's option)
Name: n/a
Address:
Telephone No: Fax No:
Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is
specified):
THIS SPACE FOR RECORDER'S USE ONLY OWNER
Signed: 0 fA^' vivoZo Date:
Doc#2019117749,OR BK 18798 Page 1401, 3efore me this !Sec# day of MLkU in the Count�of/Duval,State
Number Pages: I �f Florida,has personally appeared -1-1 ejbt 0 Cj0L4-ftj 0
Recorded 05/2112019 09:45 AM, qotary Public at Large,State of Flpn*d County of Duval.
RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL 4y commission expires: !a I 77?-OZZ-
COUNTY �ersonally Known- or
RECORDING $10.00 �y
�roduce/,)entification: If X14TTLES
Notay P�Wic,S�t orida
:te 7ofFloida
UAII *�74 COmmiSs"GG 259573
MY comm.exP'Ns Sept.17,2021
CertainTeed
AINT-GOBAIN Technical Product Data
Commercial Roofing
GLASBASE TM BASE SHEET
NON-MODIFIED ASPHALT COATED FIBERGLASS BASE SHEET
Product Product Use:Glasbase Tm Base Sheet is designed for use as an anchor sheet or base ply for
Information both hot and cold applied, built-up roofing systems and hybrid modified bitumen systems. It is
suitable for use in the construction of various types of membranes for both new construction
and reroofing over a variety of substrates. Glasbase Base Sheet will provide additional
strength, moisture resistance and asphalt uniformity when used as an anchor over nailable
substrates or first ply non-nailable and insulated substrates. In addition, it will perform as a
venting base sheet when spot mopped over plastic foam type insulations.
Limitations:Glasbase Base Sheet may be applied in either hot asphalt or approved cold
adhesive such as CertainTeed's FlintBond', depending on system design and selection. Rolls
should be stored upright, off the ground and completely protected from the weather. Roof
decks must be structurally sound, dry, smooth and meet or exceed minimum requirements
of the deck manufacturer, local code and CertainTeed. Roof decks must provide positive
drainage.Additional specifications and precautions are listed in the CertainTeed Commercial
Roof Systems Specifications.
Product Composition and Features:Glasbase Base Sheet is manufactured on an extra strength
fiberglass reinforced mat that receives a coating of weathering grade asphalt and is lightly
surfaced with a mineral release agent. The fiberglass mat provides excellent strength and
moisture resistance. Glasbase Base Sheet is pliable and will conform to most surfaces for
ease of application.
Roll Dimensions: 39%" x 98' 9"
Nominal Coverage: Three squares
Approximate Weight 75 lbs. per roll
Top&Bottom Surfacing: Fine sand,release agent
Applicable Standards:Meets ASTM D4601, Type 11. Glasbase Base Sheet is approved by
Underwriters Laboratories for use in vaHous Class A, B, or C roof assemblies, Factory Mutual,
Miami-Dade, Florida Building Code Statewide Approval (FL 477, FL 2533 and FL 16709)and
Texas Department of Insurance(RC47).
Technical support mat: Extra strength fiberglass reinforced mat
Da ta Tensile Strength flbAn.): MD/XD = 50/50
OFFICE COPY
Approved By Permit Desk
Building Department
city of Atlanbc Beach, FL
MADE IN
U.S.A.
Product Roof systems constructed with Glasbase Base Sheet as the anchor sheet or base ply must
Application be applied in accordance with installation procedures listed in the CertainTeed Commercial
Roof Systems Specifications. The following information is intended for general information
purposes only and is not all-inclusive.
Preparation:Substrates to receive a roof system must be firmly attached, smooth, dry, clean
and free of sharp projections and depressions. Flashing details must be in place, ready to
receive roofing, with roof accessories available prior to application of materials. Substrates
requiring priming must be primed with asphalt primer such as FlintPrime",and be allowed
to completely dry. Substrates must provide positive drainage. Roof insulation must be
tapered to drains.
Installation:Glasbase Base Sheet must be installed with 2" side laps and 4"end laps, with
end laps diagonally staggered not less than 3' apart. For nailable substrates, mechanically
fasten Glasbase 9" o.c. at side laps and 18"o.c. in two rows, 12" in from each edge with
approved fasteners. For non-nailable or insulated substrates, Glasbase must be set in
either spot or solid mopping of bitumen as required by the CertainTeed Commercial Roof
Systems Specifications. Spot mop, when specified, in 9"diameter circles, 24" o.c. in all
directions. Solid mop at the rate of 25 lbs. per 100 sq. ft. Bitumen must be heated and
applied within temperature guidelines as set forth by CertainTeed according to type
and grade.
Precautions:Cold weather applications require special handling to prevent damage to the
rolls and ensure satisfactory installation. Do not apply roofing systems over improperly
prepared substrates or substrates that contain moisture.
Maintenance: CertainTeed Commercial Roof Systems generally do not require any
additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed
recommends regular roof maintenance and inspection to deterrnine the condition of drains,
flashings and other similar items, and to maximize the life expectancy of the roof system.
Warranties CertainTeed offers Limited (product only)and No Dollar Limit (NDL, product and
workmanship)warranties. Warranty type and duration is dependent on roof system
configuration and contractor selection. Only CertainTeed Gold and Silver Star Contractors
are eligible to apply for NDL warranties on specific roof projects. For more information,
see CertainTeed Commercial Roof Systems Specifications or contact Commercial Roofing
Technical Services.
Technical CertainTeed provides technical assistance in the design, selection, specification and
Assistance and application techniques for all CertainTeed Commercial Roof Systems. Architectural and field
Services representatives are available for consultation within each region.
For more information, contact CertainTeed Commercial Roofing Technical Services
at 800-396-8134 x2.
ASK ABOUT ALL OF OUR OTHER CERTAINTEED" PRODUCTS AND SYSTEMS: CertainTeed Corporation
20 Moores Road
ROOFING SIDING - TRIM - DECKING - RAILING - FENCE Malvern, PA 19355
GYPSUM CEILINGS INSULATION
Professional: 800-233-8990
www.certainteed.com http://blog,certainteed.com Consumer: 800-782-8777
P 03/16 CertainTeed Corporation,Printed in the U.S.A,
Code No.COMM-025
SAINT-GOBAIN
CertainTeed
SAINT-GOBAIN
Commercial Roofing Technical Product Data
FLINTLASTIC"' GTA
APP MODIFIED BITUMEN POLYESTER CAP SHEET
WITH MINERAL SURFACE
ProdUCt Product use:Flintlastic GTA is designed for use as a cap membrane over various types
Information of substrates for both new construction and reroofing installations. It is suitable for most
low sloped roof decks and may be used for roof system flashings including wall treatments,
base flashings and field flashings.
Limitations: Flintlastic GTA is intended for torch application only and should not be exposed
to adhesives or solvent based materials. Rolls should be stored upright, off the ground
and completely protected from the weather. Roof decks must be structurally sound, dry,
smooth and meet or exceed minimum requirements of the deck manufacturer, local code
and CertainTeed. Additional specifications and precautions are contained in the CertainTeed
Commercial Roof Systems Specifications.
Product Composition and Features:Flintlastic modified bitumen membranes are manufactured
on state-of-the-art, dedicated roofing lines that were exclusively designed for the production
of modified bitumen products- Flintlastic GTA is produced with a high performance, stress-
resistant polyester mat that is impregnated and coated with a superior grade, modified
bitumen compound.
Rol/Dimensions: 39%"X 32'10"
Nominal Coverage: One square
Approximate Weight, 103 lbs. per roll
Top Surface: Mineral granule
Back Surface: Torchable polyethylene film
Applicable Standards:Meets ASTM D6222, Grade G, Type 1. Flintlastic GT
�A is
approved by Underwriters Laboratories for use in various Class A, B ar C roof
assemblies, [CC-ES (ESR-1388), Factory Mutual, Miami-Dade, Florida Building C�Q
Code Statewide Approval (FL 2533 and FIL 16709) and Texas Department of
Insurance (RC-47). Flintlastic GTA White is an approved ENERGY STAR9 product
for slopes greater than 2"/12". Flintlastic GTA White is listed by the Cool Roof Rating Council
(CRRC). The CRRC product ID is 0668-0008. Initial Solar Reflectance: 0.27,- Aged Solar
Reflectance: 0.27; Thermal Emittance: 0.87.
Technical Modified Bitumen Coating: Non-oxidized (flux) asphalt, blended with various thermoplastic
Data atactic polypropylene polymers and co-polymers.
Support Mat: High performance, stress-resistant polyester mat.
Test Desgdption Test Method Results*
Solar Reflectance Index(SRIl InitiaLlAged. ASTM E1980 27/28
Softening Point: ASTM D36 31 O'F
Tensile Strength: ASTM D5147
@ 73.4+/_3.6'F MD/XD 100/60 lbs./in.
@ 0+/-3.6'F MD/XD 130/80 lbs./in.
Elongation: ASTM D5147
@ 73.4+/-3.6'F MD/XD 45%/55%
@ 0+/_3.6'F MD/XD 30%/20%
Dimensional Stability. ASTM D5147 MD/XD 0.5%/0.3%
Low Temperature Flex: ASTM D5147 Pass @ 8'F
Compound Stability: ASTM D5147 250'F
Thickness: ASTM D5147 4.0 mm(160 mils)
Tear Strength: ASTM D5147
@ 73.4+/_3.6'F MD/XD 130/90 lbs.
Aff�MADEIN *NOTE:Published results are nominal production values confirmed by independent laboratory testing.
��U.S.A.
Product Flintlastic modified bitumen roofing systems must be applied in accordance with installation
Application procedures contained in the CertainTeed Commercial Roof Systems Specifications. The
following information is intended for general information purposes only and is not all-inclusive.
Preparation:Substrates to receive a roof system must be firmly attached, smooth, dry, clean and
free of sharp projections and depressions. Substrates requiring priming must be primed with
asphalt primer such as FlintPrime"and be allowed to completely dry. Substrates must provide
positive drainage. Roof must be tapered to drains.
Installation: Install one ply of Glasbase" or other CertainTeed approved alternate base sheet
lapping 2"on sides and 4"on ends. Base sheet must be mechanically fastened to nailable
substrates, and either solid or spot mopped in hot asphalt to non-nailable or insulated substrates
as specified in the CertainTeed Commercial Roof Systems Specifications. Apply base sheet in
such a manner as to provide and maintain a minimum 6"offset between side and end laps of
base ply and Flintlastic finishing membrane. Over the base ply, install one ply of Flintlastic GTA
lapping 3"on sides and 6"on ends, with end laps diagonally staggered not less than Sapart.
Side and end laps should be inspected to ensure a minimum %"flow of modified compound has
been achieved.
Precautions: Cold weather applications require special handling to prevent damage to the rolls
and ensure satisfactory installation. Do not apply roofing systems over improperly prepared
substrates or substrates that contain moisture. Follow all safety recommendations relating to the
use and maintenance of liquid propane gas torches and equipment. Refer to the CertainTeed
Commercial Roof Systems Specifications for additional safety information.
Maintenance: Flintlastic Roof Systems do not require any additional maintenance beyond normal
yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and
inspection to determine the condition of drains, flashings and other similar items, and to prolong
the life expectancy of the roof system.
Warranties CertainTeed offers Limited (product only) and No Dollar Limit (NDL, product and workmanship)
warranties. Warranty type and duration is dependent on roof system configuration and contractor
selection. Only CertainTeed Gold and Silver Star Contractors are eligible to apply for NDL
warranties on specific roof projects. For more information, see CertainTeed Commercial Roof
Systems Specifications or contact Commercial Roofing Technical Services.
Technical CertainTeed provides technical assistance in the design, selection, specification and application
Assistance and guidelines for all CertainTeed Roof Systems. Architectural and field representatives are available
for consultation within each region. For more information, contact CertainTeed Commercial
Services Roofing Technical Services at 800-396-8134 x2.
Caution: Torch application of this product may create a risk of fire, including smoldering fires.
Fire Hazard The roofing applicator is solely responsible for ensuring and enforcing safe and proper application
of CertainTeed's roofing products by competent and qualified personnel. Only properly trained
roofing professionals are authorized to install this product.
Never apply flame directly to combustible materials or allow the flame to enter into hidden or
protected areas that may contain combustible materials. Follow all local code requirements. Have a
Class A-B-C fire extinguisher available to each applicator. Thoroughly inspect the job site whenever
torching equipment has been used. Be certain that all chances of a fire have been eliminated.
Refer to the CertainTeed Commercial Roof Systems Specifications, Midwestern Roofing
Contractors Association (MRCA) CERTA program, National LP Gas Association, National Roofing
Contractors Association (NRCA), National Fire Protection Association(NFPA), and Asphalt Roofing
Manufacturers Association (ARMA)for further information and safety recommendations.
ASK ABOUT ALL OF OUR OTHER CERTAINTEED" PRODUCTS AND SYSTEMS: CertainTeed Corporation
20 Moores Road
ROOFING SIDING - TRIM - DECKING - RAILING - FENCE Malvern, PA 19355
GYPSUM CEILINGS - INSULATION
Professional: 800-233-8990
www.certainteed.com http://blog.certainteed.com Consumer: 800-782-8777
0 03/16 CertainTeed Corporation,Printed in the U.S.A.
Code No.COMM-020
rfr"TV.,