Loading...
735 Amberjack Ln ROOF19-0050 Torch .1'_\i'jlr I ROOF NON SHINGLE PERMIT PERMIT NUMBER 7- ROOF19-0050 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ISSUED: ATLANTIC BEACH. FL 32233 EXPIRES: MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 735 AMBERJACK LN ROOF NON SHINGLE torch down re-roof $7490.00 TYPE OF REALESTATE BUILDING USE CONSTRUCTION: NUMBER: ZONING: GROUP: SUBDIVISION: 1711960000 ROYAL PALMS UNIT 01 COMPANY: ADDRESS: CITY: STATE: ZIP. AFFORDABLE ROOFING 1348 Clements Woods Ln JACKSONVILLE FL 32211 OWNER: ADDRESS: CITY: STATE: ZIP: WILLIAMS GEORGE LIFE 735 AMBERJACK LN ATLANTIC BEACH FL 32233-4204 ESTATE WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $90.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00 BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.78� STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $189.78 Issued Date: I of 2 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING REVIEW COMMENTS Date: 5/28/2019 Permit#: ROOF19-0050 Site Address: 735 AM BERJACK LN Review Status: REM 171196 0000 Applicant: AFFORDABLE ROOFING Property Owner: WILLIAMS GEORGE LIFE ESTATE Email: vmarino2009@gmail.com Email: tinaocasio45@outlook.com Phone: 9042607663 Phone: 9042280834 9044496339 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Submit 2 copies of the manufacturer's installation instructions for all of the elements of the torch down roof system and the Evaluation reports for the cap sheet. Please only submit the pages from the report that pertain to the site specific application on this roof. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:nij ones@coab.us '11412-011 7,�\ Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left I City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road U-)L Atlantic Beach, Florida 32233-5445 f7'( tj V Phone(904)247-5826 - Fax(904)247-5845 ru I it E-mail: building-dept@coab.us L Date routed: IC7 City web-site: hftp://www.coab.us I __ I APPLICATION REVIEW AND TRACKING FORM Property Address: PM�nt review required Y 0 (-Euilding Applicant: -Ffmrtrg_&Zoning Tree Administrator Project: Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ElApproved. Pq-Denied. El Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: D a t e: !�12- TREE ADMIN. Second Review: F]Approved as revised. F]Denied. F]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ElApproved as revised. [:]Denied. FNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 ROOF SuNiag Permit Application City of Atlantic Beach 800 Seminole Road,Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (904)247-5845 Job Address: 735 AMBERJACK LN Atlantic Beach FL 32233 Permit Number: o o Legal Description 30-60 17-2S-29E ROYAL PALMS UNIT I LOT 11 BLK 5 RE# 171196-0000 Valuation of Work(Replacement Cost)$ 7,495.00 —Heated/Cooled SIF N/A Non-Heated/Cooled N/A • Class of Work(Circle one): DIM* A=0(XK XMYX(&X KKUX DOM X)MM IRSMIX 1AXKi(XX*SW new roof • Use of existing/proposed structure(s)(Circle one): qXM0(X0d Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): 1606 A%K N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal N/A Describe in detail the type of work to be performed: Remove and replace existing roof with new roof per FBC -T'o rctil, VL aV�3 . I IL L Florida Product Approval# !+iIig4es+bi83 �. for multiple products use product approval form PropertV Owner Information Name: OCASIO,TINA Address: 735AMBERJACKLN FL 32233-4204 ;'-----228-0834___ City ATLANTIC BEACH State—Zip Phone E-Mail tinaocasio45@outlook.com Owner or Agent(if Agent, Power of Attorney or Agency Letter Required) MAY 2 1 2M Contractor Information _.___N� Name of Company: Affordable Roofing Qualifying Agent: VincentMarino Address 1348 Clements Woods Lane City Jacksonville State FIL Zip 32211 Office Phone 904-260-7663 Job Site/Contact Number 904-449-6339 State Certification/Registration# CCC057697 E-Mail vmarino2009@gmail.com Architect Name&Phone# N/A Engineer's Name&Phone# N/A Workers Compensation Exempt / Leased Employees Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Ck� (Signature of Owner kA)(gxw A (Signatu of Contractor) 'Jne r r affir e fc _' by ,a ri in E L S Aota �U I Flo gnat, 9 _0(o Signed and sworn or affir e before me thi day of Signed and sworn to(or aff'. d) before me this day of 10% 7A Y(\Zx�,i 01\_0)01 dv incent Marin by A ALIBREY M.LITTLES AA A Notary PuNic,State of Flo ida gnature of lVota No 401 ry) Comrrission#GG 25957 My oomm.ex0es SW.17,2022 17,2022 My co(w.expires JVersonally Known OR 1krsonally Known OR t'l Produced Identifi ti [qProduced Identification Type of Identification: L 1)L Type of Identification: C-L D A,"I -� ip- goo elf -CPO NOTICE OF COMMENCEMENT State of Florida Tax Folio No. 171196-0000 County of Duval To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 30-60 17-2S-29E ROYAL PALMS UNIT I LOT I I BLK 5 Address of property being improved: 735 AMBERJACK LN Atlantic Beach FL 32233 General description of improvements: new roof Owner: OCASIO,TINA Address: 735 AMBERJACK LN ATLANTIC BEACH,FL 32233-4204 Owner's interest in site of the improvement: 100 Fee Simple Titleholder(if other than owner): n/a Name: Contractor: Affordable Roofing Address: 1348 Clements Woods Lane Jacksonville,FL 32211 Telephone No.: 260-7663 Fax No: Surety(if any) n/a Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: n/a Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: n/a Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: n/a Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: 0 fA^' vivoZo Date: Doc#2019117749,OR BK 18798 Page 1401, 3efore me this !Sec# day of MLkU in the Count�of/Duval,State Number Pages: I �f Florida,has personally appeared -1-1 ejbt 0 Cj0L4-ftj 0 Recorded 05/2112019 09:45 AM, qotary Public at Large,State of Flpn*d County of Duval. RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL 4y commission expires: !a I 77?-OZZ- COUNTY �ersonally Known- or RECORDING $10.00 �y �roduce/,)entification: If X14TTLES Notay P�Wic,S�t orida :te 7ofFloida UAII *�74 COmmiSs"GG 259573 MY comm.exP'Ns Sept.17,2021 CertainTeed AINT-GOBAIN Technical Product Data Commercial Roofing GLASBASE TM BASE SHEET NON-MODIFIED ASPHALT COATED FIBERGLASS BASE SHEET Product Product Use:Glasbase Tm Base Sheet is designed for use as an anchor sheet or base ply for Information both hot and cold applied, built-up roofing systems and hybrid modified bitumen systems. It is suitable for use in the construction of various types of membranes for both new construction and reroofing over a variety of substrates. Glasbase Base Sheet will provide additional strength, moisture resistance and asphalt uniformity when used as an anchor over nailable substrates or first ply non-nailable and insulated substrates. In addition, it will perform as a venting base sheet when spot mopped over plastic foam type insulations. Limitations:Glasbase Base Sheet may be applied in either hot asphalt or approved cold adhesive such as CertainTeed's FlintBond', depending on system design and selection. Rolls should be stored upright, off the ground and completely protected from the weather. Roof decks must be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed. Roof decks must provide positive drainage.Additional specifications and precautions are listed in the CertainTeed Commercial Roof Systems Specifications. Product Composition and Features:Glasbase Base Sheet is manufactured on an extra strength fiberglass reinforced mat that receives a coating of weathering grade asphalt and is lightly surfaced with a mineral release agent. The fiberglass mat provides excellent strength and moisture resistance. Glasbase Base Sheet is pliable and will conform to most surfaces for ease of application. Roll Dimensions: 39%" x 98' 9" Nominal Coverage: Three squares Approximate Weight 75 lbs. per roll Top&Bottom Surfacing: Fine sand,release agent Applicable Standards:Meets ASTM D4601, Type 11. Glasbase Base Sheet is approved by Underwriters Laboratories for use in vaHous Class A, B, or C roof assemblies, Factory Mutual, Miami-Dade, Florida Building Code Statewide Approval (FL 477, FL 2533 and FL 16709)and Texas Department of Insurance(RC47). Technical support mat: Extra strength fiberglass reinforced mat Da ta Tensile Strength flbAn.): MD/XD = 50/50 OFFICE COPY Approved By Permit Desk Building Department city of Atlanbc Beach, FL MADE IN U.S.A. Product Roof systems constructed with Glasbase Base Sheet as the anchor sheet or base ply must Application be applied in accordance with installation procedures listed in the CertainTeed Commercial Roof Systems Specifications. The following information is intended for general information purposes only and is not all-inclusive. Preparation:Substrates to receive a roof system must be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Flashing details must be in place, ready to receive roofing, with roof accessories available prior to application of materials. Substrates requiring priming must be primed with asphalt primer such as FlintPrime",and be allowed to completely dry. Substrates must provide positive drainage. Roof insulation must be tapered to drains. Installation:Glasbase Base Sheet must be installed with 2" side laps and 4"end laps, with end laps diagonally staggered not less than 3' apart. For nailable substrates, mechanically fasten Glasbase 9" o.c. at side laps and 18"o.c. in two rows, 12" in from each edge with approved fasteners. For non-nailable or insulated substrates, Glasbase must be set in either spot or solid mopping of bitumen as required by the CertainTeed Commercial Roof Systems Specifications. Spot mop, when specified, in 9"diameter circles, 24" o.c. in all directions. Solid mop at the rate of 25 lbs. per 100 sq. ft. Bitumen must be heated and applied within temperature guidelines as set forth by CertainTeed according to type and grade. Precautions:Cold weather applications require special handling to prevent damage to the rolls and ensure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates that contain moisture. Maintenance: CertainTeed Commercial Roof Systems generally do not require any additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and inspection to deterrnine the condition of drains, flashings and other similar items, and to maximize the life expectancy of the roof system. Warranties CertainTeed offers Limited (product only)and No Dollar Limit (NDL, product and workmanship)warranties. Warranty type and duration is dependent on roof system configuration and contractor selection. Only CertainTeed Gold and Silver Star Contractors are eligible to apply for NDL warranties on specific roof projects. For more information, see CertainTeed Commercial Roof Systems Specifications or contact Commercial Roofing Technical Services. Technical CertainTeed provides technical assistance in the design, selection, specification and Assistance and application techniques for all CertainTeed Commercial Roof Systems. Architectural and field Services representatives are available for consultation within each region. For more information, contact CertainTeed Commercial Roofing Technical Services at 800-396-8134 x2. ASK ABOUT ALL OF OUR OTHER CERTAINTEED" PRODUCTS AND SYSTEMS: CertainTeed Corporation 20 Moores Road ROOFING SIDING - TRIM - DECKING - RAILING - FENCE Malvern, PA 19355 GYPSUM CEILINGS INSULATION Professional: 800-233-8990 www.certainteed.com http://blog,certainteed.com Consumer: 800-782-8777 P 03/16 CertainTeed Corporation,Printed in the U.S.A, Code No.COMM-025 SAINT-GOBAIN CertainTeed SAINT-GOBAIN Commercial Roofing Technical Product Data FLINTLASTIC"' GTA APP MODIFIED BITUMEN POLYESTER CAP SHEET WITH MINERAL SURFACE ProdUCt Product use:Flintlastic GTA is designed for use as a cap membrane over various types Information of substrates for both new construction and reroofing installations. It is suitable for most low sloped roof decks and may be used for roof system flashings including wall treatments, base flashings and field flashings. Limitations: Flintlastic GTA is intended for torch application only and should not be exposed to adhesives or solvent based materials. Rolls should be stored upright, off the ground and completely protected from the weather. Roof decks must be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed. Additional specifications and precautions are contained in the CertainTeed Commercial Roof Systems Specifications. Product Composition and Features:Flintlastic modified bitumen membranes are manufactured on state-of-the-art, dedicated roofing lines that were exclusively designed for the production of modified bitumen products- Flintlastic GTA is produced with a high performance, stress- resistant polyester mat that is impregnated and coated with a superior grade, modified bitumen compound. Rol/Dimensions: 39%"X 32'10" Nominal Coverage: One square Approximate Weight, 103 lbs. per roll Top Surface: Mineral granule Back Surface: Torchable polyethylene film Applicable Standards:Meets ASTM D6222, Grade G, Type 1. Flintlastic GT �A is approved by Underwriters Laboratories for use in various Class A, B ar C roof assemblies, [CC-ES (ESR-1388), Factory Mutual, Miami-Dade, Florida Building C�Q Code Statewide Approval (FL 2533 and FIL 16709) and Texas Department of Insurance (RC-47). Flintlastic GTA White is an approved ENERGY STAR9 product for slopes greater than 2"/12". Flintlastic GTA White is listed by the Cool Roof Rating Council (CRRC). The CRRC product ID is 0668-0008. Initial Solar Reflectance: 0.27,- Aged Solar Reflectance: 0.27; Thermal Emittance: 0.87. Technical Modified Bitumen Coating: Non-oxidized (flux) asphalt, blended with various thermoplastic Data atactic polypropylene polymers and co-polymers. Support Mat: High performance, stress-resistant polyester mat. Test Desgdption Test Method Results* Solar Reflectance Index(SRIl InitiaLlAged. ASTM E1980 27/28 Softening Point: ASTM D36 31 O'F Tensile Strength: ASTM D5147 @ 73.4+/_3.6'F MD/XD 100/60 lbs./in. @ 0+/-3.6'F MD/XD 130/80 lbs./in. Elongation: ASTM D5147 @ 73.4+/-3.6'F MD/XD 45%/55% @ 0+/_3.6'F MD/XD 30%/20% Dimensional Stability. ASTM D5147 MD/XD 0.5%/0.3% Low Temperature Flex: ASTM D5147 Pass @ 8'F Compound Stability: ASTM D5147 250'F Thickness: ASTM D5147 4.0 mm(160 mils) Tear Strength: ASTM D5147 @ 73.4+/_3.6'F MD/XD 130/90 lbs. Aff�MADEIN *NOTE:Published results are nominal production values confirmed by independent laboratory testing. ��U.S.A. Product Flintlastic modified bitumen roofing systems must be applied in accordance with installation Application procedures contained in the CertainTeed Commercial Roof Systems Specifications. The following information is intended for general information purposes only and is not all-inclusive. Preparation:Substrates to receive a roof system must be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Substrates requiring priming must be primed with asphalt primer such as FlintPrime"and be allowed to completely dry. Substrates must provide positive drainage. Roof must be tapered to drains. Installation: Install one ply of Glasbase" or other CertainTeed approved alternate base sheet lapping 2"on sides and 4"on ends. Base sheet must be mechanically fastened to nailable substrates, and either solid or spot mopped in hot asphalt to non-nailable or insulated substrates as specified in the CertainTeed Commercial Roof Systems Specifications. Apply base sheet in such a manner as to provide and maintain a minimum 6"offset between side and end laps of base ply and Flintlastic finishing membrane. Over the base ply, install one ply of Flintlastic GTA lapping 3"on sides and 6"on ends, with end laps diagonally staggered not less than Sapart. Side and end laps should be inspected to ensure a minimum %"flow of modified compound has been achieved. Precautions: Cold weather applications require special handling to prevent damage to the rolls and ensure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates that contain moisture. Follow all safety recommendations relating to the use and maintenance of liquid propane gas torches and equipment. Refer to the CertainTeed Commercial Roof Systems Specifications for additional safety information. Maintenance: Flintlastic Roof Systems do not require any additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and inspection to determine the condition of drains, flashings and other similar items, and to prolong the life expectancy of the roof system. Warranties CertainTeed offers Limited (product only) and No Dollar Limit (NDL, product and workmanship) warranties. Warranty type and duration is dependent on roof system configuration and contractor selection. Only CertainTeed Gold and Silver Star Contractors are eligible to apply for NDL warranties on specific roof projects. For more information, see CertainTeed Commercial Roof Systems Specifications or contact Commercial Roofing Technical Services. Technical CertainTeed provides technical assistance in the design, selection, specification and application Assistance and guidelines for all CertainTeed Roof Systems. Architectural and field representatives are available for consultation within each region. For more information, contact CertainTeed Commercial Services Roofing Technical Services at 800-396-8134 x2. Caution: Torch application of this product may create a risk of fire, including smoldering fires. Fire Hazard The roofing applicator is solely responsible for ensuring and enforcing safe and proper application of CertainTeed's roofing products by competent and qualified personnel. Only properly trained roofing professionals are authorized to install this product. Never apply flame directly to combustible materials or allow the flame to enter into hidden or protected areas that may contain combustible materials. Follow all local code requirements. Have a Class A-B-C fire extinguisher available to each applicator. Thoroughly inspect the job site whenever torching equipment has been used. Be certain that all chances of a fire have been eliminated. Refer to the CertainTeed Commercial Roof Systems Specifications, Midwestern Roofing Contractors Association (MRCA) CERTA program, National LP Gas Association, National Roofing Contractors Association (NRCA), National Fire Protection Association(NFPA), and Asphalt Roofing Manufacturers Association (ARMA)for further information and safety recommendations. ASK ABOUT ALL OF OUR OTHER CERTAINTEED" PRODUCTS AND SYSTEMS: CertainTeed Corporation 20 Moores Road ROOFING SIDING - TRIM - DECKING - RAILING - FENCE Malvern, PA 19355 GYPSUM CEILINGS - INSULATION Professional: 800-233-8990 www.certainteed.com http://blog.certainteed.com Consumer: 800-782-8777 0 03/16 CertainTeed Corporation,Printed in the U.S.A. Code No.COMM-020 rfr"TV., SAINT-GOBAIN