Loading...
1876 Beach Ave ROOF19-0049 Flat ROOF NON SHINGLE PERMIT PERMIT NUMBER ROOF19-0049 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ISSUED: 6/11/2019 ATLANTIC BEACH. FIL 32233 EXPIRES: 12/8/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1876 BEACH AVE ROOF NON SHINGLE flat roof $27893.00 TYPE OF REALESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 1695420608 BEACHSIDE COMPANY: ADDRESS: CITY: STATE: zip: AMERICAN ROOFING OF 2117 University Blvd. S JACKSONVILLE FL 32216 JACKSONVILLE OWNER: ADDRESS: CITY: STATE ZIP. Farid Hakim 1876 BEACH AVE ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 0 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $190.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $95.00 STATE DBPR SURCHARGE 4SS-0000-208-0700 0 $4.28 ST EDCASURCHARGE 455-0000-208-0600 0 $2.8S TOTAL: $292.13 Issued Date:6/11/2019 1 of 2 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904)247-5845 ","I cu);' E-mail: building-dept@coab.us ___Laterouted: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Vl�40 &P-0i hy P, Depg�qment review required Yes No r% (Buildinj_) Applicant: Planning &Zoning Tree Administrator Project: irwp Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date Florida Dept. of Environmental Protection of Permit Verified By Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Zpproved. ElDenied. E]Not applicable (Circle one.) Comments: BUILDING /V PLANNING & ZONING Reviewed by: Date: 5127-1.2,614-1 TREE ADMIN. Second Review: ElApproved as revised. OlDenied. V E]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ElDenied. DNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 NFICE Building Permit Applicatioii-) C QpaYtd 1218117 City of Atlantic Beach 800 Seminole Road,Atlantic Beach,FIL 32233 Phone:(904)247-5826 Fax:(904)247-5845 Job Address: 1876 Beach Ave,Atlantic Beach,FIL 32233 Permit Number: Iq—WI-f Legal Description 42-14 09-2S-29E BEACHSIDE LOT 34 BILK 1 RE# 169542-0608 Valuation of Work(Replacement Cost)$ 27,893.00 Heated/Cooled SIF 3,933 Non-Heated/Cooled 1,246 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Complete Roof Replacement of 3d Floor Flat Roof including new aluminum coping cap on parapet wall. Install new Flat Roof system on 1st Story Flat Roof located at back of home. Polyglass Polyfresko G used on all Flat Roofs. Install MasterSeal Traffic 1500 waterproofing system on all walkable exterior decks. Florida Product Approval# See attached Product approval sheet for multiple products use product approval form PropertV Owner Information (We are a subcontractor to Blue Wave Buildpaqwah- Name: Farid Hakim Address: 1876 Beach AKi EIVED City Atlantic Beach State FIL Zip 32233 Phone E-Mail Owner or Agent(if Agent,Power of Attorney or Agency Letter Required) MAY 2 1 20-1-9 Contractor Information Name of Company: American Roofing of Jacksonville, LLC. —Qualifying Agent: DanKinkel Address 2117 University Blvd S City Jacksonville 13L19djMaLr)PPaftnJb1ff_ Office Phone 904-385-4375 Job Site/Contact Number I --I OPAGantie BeaGh, Fl­ State Certification/Registration# RC29027546 E-Mail admin@americanroo glax.corn Architect Name&Phone# NA Engineer's Name&Phone# NA Workers Compensation Builder's Mutal Insurance#WCP1052393,expiration 5/20/2019 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS,POOLS, FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECO G YOUR NOTICE OF COMMENCEMENT. (Signatu4_of Ov�n_er or Agent) (Signature of Contractor) (including contractor) Signe and sworn to(or affirmed)before me this day of Signed and sworn to(or affirmed)before m this;_A/ day of UYPW-=ibw I /Y1 lvf-11- 0 tc A_t "0"PLd3ft JENNIFER 0 S E� ft"of parift MYCOMMISSI 0 my ftffwkwm Es""Uo"W'3"' gnatn�aryj EXPIRES:Oc i�of tary) Commilabn NcL GG 112239 Bonded Thru Notary Ic erwiters Personally Known OR Peleally Known OK L;45'roduced Identification V,:$�oducecl Identification Type of Identification:741vtr) 11ferlit Type of Identification: REVIEWED FOR CODE- CO'NIPLIANCE CITY OF ATLANTIC BEACH OFFICE COPY SEE PERMITS FOR ADDITIONAL REQUIREME ND Ca I D 2ARROVAL INMRMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA REVIEWED BY: ML Project Name: Hakim Residence Permit #- 90?0 77 Project Address: 1876 Beach Ave,Atlantic Beach,FL 32233 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuildin2. r2. — Category/Subcategory Manufacturer ftwiotiotil)e Limitation of Use State Loc: A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4.Roll up 5.Automatic 6. Other B.WINDOWS 1. Single hung 2.Horizontal slider 3. Casement 4.Double hung 5.Fixed 6.Awning 7.Pass-through 8.Projected 9.Mullion 10. Wind breaker 11.Dual action 12. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local 4 C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments Polyglass SAV Base Sheet SA Above 1/4 12 pitch H- 1654-R_24 3. Roofing fasteners 4.Nonstructural metal roof 5. Built-up roofing 6.Modified bitumen Polyglass PolyFresko G SA Above 1/4 12 pitch 1.1 1654-R24 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing BASF Masterseal Traffic 150( NOA 15-0820.02 11. Wood shingles/shakes 12. Roofing slate 13.Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof OFFICE COPY 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # -- ------ H. NEW EXTERIOR ENVELOPEPROI)LJCTS I �2 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) Dan Kinkel ,,(Signature) Company Name: American Roofing of Jacksonville,LLC. .,:u Mailing Address: 2117 University Blvd S City: Jacksonville State: FL Zip Code: 32216 Telephone Number: 904 3854375 Fax Number: ( Cell Phone Number: 904 226-1205 E-mail Address: dangamericanroofingjax.com OFFICE COPY fONEMOjetc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded insulation,Bonded Roof Cover 5-9 ic Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11 ID Wood New,Reroof(Tear-off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 12 1E Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 12-14 1F Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15-18 1G Wood New or Reroof(Tear-off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 18-22 1H Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 23-28 11 Wood New or Reroof(Tear-off) F Non-Insulated,Bonded Roof Cover 29 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top insulation,Bonded Roof Cover 30-32 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached insulation,Bonded Roof Cover 33-37 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-1 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 38-39 2D Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Velociflex,Bonded Roof Cover 40-41 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 42-50 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 50 4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded insulation,Bonded Roof Cover 51-53 4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 54 4C Lightweight concrete New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 55-58 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 59 5B Cementitious wood fiber New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 60 5C Cementitious wood fiber New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 61 SO Cementitious wood fiber New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 61 5E Cementitious wood fiber New,Reroof(Tear-off)or Recover Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 61 6A Existing gypsum Reroof(Tea r-Off) A-1 Bonded Insulation,Bonded Roof Cover 62-64 6B Existing gypsum Reroof(Tear-Off)or Recover_ A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 64 6C Existing gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 64 6D Existing gypsum Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 64 7A Various Recover I A-1 I Bonded Insulation,Bonded Roof Cover 65-69 7B Various Recover F Non-insulated,Bonded Base Sheet,Bonded Roof Cover 69 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: > Wood: Minimum 0.75-inch penetration. > Steel: Minimum 0.75-inch penetration and engage thetop flute ofthe steel deck. >Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. NEIVIO ETC,LLC Evaluation Report P9290.02.08-R22 for FL1654-R24 Certificate of Authorization#32455 6 TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page I of 69 ONEMOletc. 3. Unless otherwise noted,insulation maybe anyone layer or combination of polyisocyanurate,polystyrene,wood fi be rboard,perlite,gypsum-based roof board or mine ral-woo I roof board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. Hot asphalt(HA): Full coverage at 25-30 lbs/square. Dow INSTA STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. > Millennium One Step Foarnable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. Millennium PG-1 Pump Grade Adhesive(M-PG1): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. > OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. )0-OlyBond Classic(OB Classic): Full coverage at 1 gal/square. > ICP Adhesive&Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. >Note: When multiple loyers(s)ofinsulation andlor coverboard are installed in ribbon-applied adhesive,boardjoints shall be staggered. �O Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: > Millennium One Step Foarnable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) > Millennium PG-1 Pump Grade Adhesive(M-PG1): MDP -157.5 psf (Min.0.5-inch thick) OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) >OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GQ >OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) >OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam 11) )�, ICP Adhesives&Sealants Polyset CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL1654-R24 Certificate of Authorization#32455 6 T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 2 of 69 OFFICE COPY fONEMOjetc- 14. Lightweight insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTIVI C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Unless otherwise noted, use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. POLYGLAss ROOF COVERS REFERENCE LAYER MATERIAL APPLICATION BP-AA Base Ply One or more plies Polyglass G2 Base,FBC Approved ASTM D4601,Type 11 Hot Asphalt at 20-40 (Base and Ply sheets, Ply One or more plies Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI Asphalt-Applied) Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. lbs/square Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshield HT PG350 at 1.5-2.0 SBS-CAI Cap Ply Elastoflex V G,Elastoflex V G FIR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS G,Elastoshield TS gal/square G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FIR(sand-backed) Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 HP Poly lus 35 at 1.5-2.0 SBS-CA2 Elastoflex V G,Elastoflex V G FIR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS G,Elastoshield TS p Cap Ply G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) gal/square Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex 56,Elastoflex SBS-AA S6 HP,Elastoshield HT Hot Asphalt at 20-40 (SBS,Asphalt-Applied) Cap Ply Elastoflex V,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS G, lbs/square Elastoshield TS G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. SBS-TA Base Ply or Ply One or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshield HT (SBS,Torch-Applied) Cap Ply Elastoflex V,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS G, Torch-Applied Elastoshield TS G FIR,Polyfresko G SBS(poly-film backed),Polyfresko G SBS FIR(poly-film backed) Base Ply One or more plies Elastoflex SA V,Elastoflex SA V FIR,Elastoflex SA V Plus,Elastoflex SA V Plus FR SBS-SA Cap Ply Elastoflex SA P,Elastoflex SA P FR,Polyreflect Self-Adhering (SBS,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, Elastobase(polylsond)or Elastobase(polylpoly). APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass Base,Polyflex,Polybond Torch-Applied (APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FIR APP-SA Cap Ply Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool (APP,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein, Self-Adhering Elastobase(polylsand)or Elostobase(polylpoly). NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL16S4-R24 Certificate of Authorization#32455 6 TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Pollyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 3 of 69 ONEMO I etc. 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies: VAPOR BARRIER OPTIONS;STRUCTURAL CONCRETE DECK;ADHERED INSULATION PER TABLE 3A OPTION PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP(PSF) # TYPE ATTACH VB-1. PG100 Elastoflex SA V Plus Self-Adhering Inta-Stik or CR-20,12-inch D.C. -60.0 VB-2. PG100 Polyglass Base Torch-applied Inta-Stik or CR-20,12-inch o.c. -75.0 VB-3. PG100 Elastoflex SA P Self-Adhering Insta-Stik,12-inch D.C. -75.0 VB-4. PG100 Elastoflex SA P Self-Adhering Millennium One Step Foarnable Adhesive,12-inch o.c. -157.5 VB-5. PG100 Elastoflex SA P Self-Adhering CR-20,12-inch o.c. -270.0 VB-6. PG100 Elastoflex SA V,Elastoflex SA V FIR,Elastoflex SA V Self-Adhering Millennium One Step Foarnable Adhesive,Millennium PG-1 Pump Grade -290.0 Plus,Elastoflex SA V Plus FR Adhesive,OlyBond 500 or CR-20,12-inch o.c. 17. The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for application limitations and a Roofing Materials Directory for fire ratings associated with coating usage. SURFACING OPTIONS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Option# Surfacing Florida Product Approval SURF-1. PG300 Fibered Roof Coating FL10291 SURF-2. PG600 Non-Fibered Aluminum Roof Coating FL10291 SURF-3. PG650 Fibered Aluminum Roof Coating FL10291 SURF-4. PG700 High Quality Elastomeric Roof Coating FL10291 SURF-5. PG700QS(Quick Set)High Quality Elastomeric Roof Coating FL10291 SURF-6. PG800 Asphalt Emulsion Roof Coating FL10291 SURF-7. Polyplus 60 Premium Non-Fibered Aluminum Roof Coating FL10291 SURF-8. Polyplus 65 Premium Fibered Aluminum Roof Coating FL10291 SURF-9. Polybrite 70 Premium Grade Elastomeric Roof Coating FL10291 SURF-10. Polybrite 70QS(Quick Set)Premium Grade Elastomeric Roof Coating FL10291 SURF-11. Polybrite 71 HS FL10291 SURF-12. Polybrite 90 High Solids Silicone Roof Coating FL10291 SURF-13. Polybrite 95 Silicone Roof Coating FL10291 SURF-14. KM Acryl 15 FL27409 SURF-15. KIM Acryl 15 CIS FL27409 SURF-16. KM Acryl 25 FL27409 SURF-17. KM Acryl 25 QS FL27409 SURF-18. KM Acryl 40 HS FL27409 SURF-19. KM Acryl 85 FL27409 SURF-20. KM PS#250 FL27409 SURF-21. KM PS#220 FL27409 18. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for F1.1654-1124 Certificate of Authorization#32455 6 TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 4 of 69 OFFICE COPY fONEM01-etc. TABLE IA: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply I I Cap Ply (Psf) SELF-ADHERING BASE PLY: min.15/32- Min.1.5-inch Polytherm,ACFoarn 11,Polytherm G, D-15,M-OSFA, (Optional)additional D-IS,M-OSFA, (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, W-1 inch plywood ACFoam 111,ENRGY-3,Polytherm H,H-Shield,H- OB500 or CR-20 layers(s)of base insulation OB500 or CR-20 SBS-SA APP-TA SBS-TA,APP-TA -52.5 Shield CG,Multi-Max FA3 Min.15/32- Min.1.5-inch Polytherm,ACFoam 11,Polythemn G, D-IS,M-OSFA, (Optional)additional D-15,M-OSFA, Polyflex SA W-2 inch plywood ACFoarn III,ENRGY-3,Polytherm H,H-Shield,H- OB500 or CR-20 layers(s)of base insulation OB500 or CR-20 Base (Optional)APP-TA APP-TA -52.5 Shield CG,Multi-Max FA3 TABLE 113: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck AnchorSheet Base Insulation Top Insulation Roof Cover(Note is) MDP Attach Type Attach Base Cap Ply (Psf) No. (Note 1) Type Fasten Attach Type Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: 9-inch o.c.at min.2- (Optional)Min.1.5-inch Min.0.75-inch Fesco Min. Elastobase, inch lap and 18-inch Polytherm,ACFoam 11, Board(homogeneous)or BP-AA (Optional) SBS-AA, W-3 15/32-inch Elastobase P Simplex MAXX o.c.at two(2), ENRGY-3,Polytherm H, Hot asphalt min.0.5-inch Structodek Hot or SBS- BP-AA or SBS-TA, -45.0* plywood (sanded-top) Cap equally spaced H-Shield,H-Shield CG, High Density Fiberboard asphalt AA SBS-AA APP-TA staggered center Multi-Max FA3 Roof Insulation rows 9-inch o.c.at min.2- (Optional)Min.1.5-inch Min. Elastobase, inch lap and 18-inch Polytherm,ACFoam 11, Min.0.25-inch Dens BP-AA, (Optional) SBS-AA, W-4 15/32-inch Elastobase P Simplex MAXX D.C.at two(2), ENRGY-3,Polytherm H, Hot asphalt Deck,Dens Deck Prime, Hot SBS-AA, BP-AA,SBS- SOS-TA, -45.0* plywood (sanded-top) Cap equally spaced, H-Shield,H-Shield CG, SECUROCK Gypsum-Fiber asphalt SBS-TA, AA,SBS-TA, APP-TA staggered center Multi-Max FA3 Roof Board APP-TA APP-TA rows 9-inch D.C.at min.2- (Optional)Min.1.5-inch Min.0.75-inch Fesco Min. Elastobase, inch lap and 12-inch Polytherm,ACFoam 11, Board(homogeneous)or BP-AA (Optional) SBS-AA, W-5 15/32-inch Elastobase P Simplex MAXX o.c.at two(2), ENRGY-3,Polythemn H, Hot asphalt min.0.5-inch Structodek Hot or SBS- BP-AA or SBS-TA, -52.5 plywood (sanded-top) Cap equally spaced H-Shield,H-Shield CG, High Density Fiberboard asphalt AA SBS-AA APP-TA staggered center Multi-Max FA3 Roof Insulation rows 9-inch D.C.at mi.n.2- (Optional)Min.1.5-inch Min. Elastobase, inch lap and 12-inch Polytherm,ACFoam 11, Min.0.25-inch Dens BP-AA, (Optional) SBS-AA, W-6 15/32-inch Elastobase P Simplex MAXX D.C.at two(2), ENRGY-3,Polytherm H, Hot asphalt Deck,Dens Deck Prime, Hot SBS-AA, BP-AA,SBS- SBS-TA, -52.5 plywood (sanded-top) Cap equally spaced H-Shield,H-Shield CG, SECUROCK Gypsum-Fiber asphalt SBS-TA, AA,SBS-TA, APP-TA staggered center Multi-Max FA3 Roof Board APP-TA APP-TA rows I I I I I NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL1654-R24 Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019 Prepared by: Robert Nienninen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 5 of 69 CL 0 MIAM�m MIAMI-DADE COUNTY U PRODUCT CONTROL SECTION L 1-1 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 UL NOTICE OF ACCEPTANCE (NOA) www.miamidade.goy/economy LL_ BASF Corporation 0 889 Valley Park Drive Shakopee,MN 55379 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: MasterSeal Traffic 1500 Pedestrian Traffic&Vehicular Traffic Bearing Systems. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 10-0324.02 and consists of pages I through 6. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 15-0820.02 Expiration Date: 08/24/20 �APPROVED Approval Date: 09/10/15 Page I of 6 ROOFING SYSTEM APPROVAL Cateeory: Roofing LL- Sub-Cateeory: Waterproofing LL- Deck Type: Concrete 0 Material: Polyurethane Maximum Desiizn Pressure: -502.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: Test Product Product Dimensions Specification Descrintion MasterSeal M 200 5 gal buckets, ASTM C 957 Single component,moisture curing, 55 gallon drums polyurethane elastomeric waterproofing membrane for horizontal vehicular and pedestrian traffic areas as a waterproofing basecoat. MasterSeal TC 225 5 gal buckets, ASTM C 957 Single component,moisture curing, 55 gallon drums polyurethane elastomeric waterproofing membrane with integral aggregate for horizontal vehicular and pedestrian traffic areas as a traffic bearing(pedestrian or vehicular)wearing surface. EVIDENCE SUBMITTED: Test Product Test A2ency Test Identifier Specificati2n Date PRI Construction Materials BAS-032-02-01 ASTM C 957 08/25/15 Technologies LLC BAS-032-02-02 TAS 114(D) 08/25/15 UL LLC R18323 UL 790 04/16/15 NOA No.: 15-0820.02 IJLAMWADE� Expiration Date: 08/24/20 Approval Date: 09/10/15 Page 2 of 6 C) C) W APPROVED APPLICATIONS: C) LL_ Deck Type 1 Concrete Decks LL_ Deck Description: Min. 3000 psi System Type A(1): MasterSeal Traffic 1500 Pedestrian Traffic Bearing System Substrate Concrete must be fully cured(28 days)structurally sound,clean and dry(ASTM Preparation: D 4263).All concrete surfaces(new and old)must be mechanically prepared to remove previous coatings, laitance,and all miscellaneous surface contamination and to provide profile for proper adhesion. Base Coat: Apply MasterSeal M 200 at a minimum of 55-60 sq. ft. per gallon(25 wet mils) using a notched squeegee and back rolled to level out application.Allow to cure overnight. Top-Coat Apply MasterSeal TC 225 at a minimum of 55-60 sq. ft. per gallon(25 wet mils) using a notched squeegee and back rolled to level out application. While the coating is still wet,broadcast 15-20 lbs./sq. of#16-30 rounded silica sand into the coating and immediately back roll to encapsulate. Integrity Test: Required,and shall be performed in accordance with ASTM D 5957 by an approved lab. Water maybe maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. All defects shall be corrected. Maximum Design Pressure: -502.5 psf(See General Limitation#9) NOA No.: 15-0820.02 0 P REM ON MEADME MCO tfflft Expiration Date: 08/24/20 �Lagmvrjvj� Approval Date: 09/10/15 Page 3 of 6 LH Deck Type 1 Concrete Decks C.) LJL_ Deck Description: Min. 3000 psi System Type A(2): MasterSeal Traffic 1500 Vehicular Traffic Bearing System 0 Substrate Concrete must be fully cured(28 days)structurally sound,clean and dry(ASTM Preparation: D 4263).All concrete surfaces(new and old)must be mechanically prepared to remove previous coatings, laitance,and all miscellaneous surface contamination and to provide profile for proper adhesion. Base Coat: Apply MasterSeal M 200 at a minimum of 55-60 sq. ft. per gallon (25 wet mils) using a notched squeegee and back rolled to level out application. Allow to cure overnight. Intermediate Coat: Apply MasterSeal TC 225 at a minimum of 80 sq. ft. per gallon(20 wet mils) using a notched squeegee and back rolled to level out application. While the coating is still wet,broadcast 50-60 lbs. of#16-30 rounded silica sand to refusal. Allow to cure overnight. Top-Coat Remove all loose aggregate.Apply MasterSeal TC 225 at a minimum of 80 sq. ft. per gallon(20 wet mils)using a flat squeegee. Immediately backroll to level topcoat Integrity Test: Required,and shall be performed in accordance with ASTM D 5957 by an approved lab. Water maybe maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. All defects shall be corrected. Maximum Design Pressure: -502.5 psf(See General Limitation#9) NOA No.: 15-0820.02 Mm"NUNC Expiration Date: 08/24/20 Approval Date: 09/10/15 Page 4 of 6 CL 0 C) Uj U Deck Type 1 Concrete Decks UL Deck Description: Min. 3000 psi UL C) System Type A(3): MasterSeal Traffic 1500 Vehicular Traffic Bearing System Extra Heavy Duty: This application should be utilized in turn lanes,pay booths,entrances and exits. The Extra Heavy Duty application is as follows. Substrate Concrete must be fully cured(28 days)structurally sound,clean and dry(ASTM Preparation: D 4263).All concrete surfaces(new and old)must be mechanically prepared to remove previous coatings, laitance,and all miscellaneous surface contamination and to provide profile for proper adhesion. Base Coat: Apply MasterSeal M 200 at a minimum of 55-60 sq. ft.per gallon(25 wet mils) using a notched squeegee and back rolled to level out application.Allow to cure overnight. Intermediate Coat: Apply MasterSeal TC 225 at a minimum of 50 sq. ft.per gallon(32 wet mils) using a notched squeegee and back rolled to level out application. While the coating is still wet,broadcast 50-60 lbs. of#16-30 rounded silica sand to refusal. Allow to cure overnight. Top-Coat: Remove all loose aggregate.Apply MasterSeal TC 225 at a minimum of 80 sq. ft. per gallon(20 wet mils)using a flat squeegee. Immediately backroll to level the topcoat Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water maybe maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. All defects shall be corrected. Maximum Design Pressure: -502.5 psf(See General Limitation#9) NOA No.: 15-0820.02 EC. Expiration Date: 08/24/20 Approval Date: 09/10/15 Page 5 of 6 LUA U GENERAL LIMITATIONS: LL_ I Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials LL_ Directory for fire ratings of this product. 0 2. A copy of the integrity test report described herein in accordance with ASTM D5957 shall be provided to the Building Official for review at time of final inspection. 3. Contractor shall submit to the Building Official for review the system specifications and details. Submission of these documents,as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. 4. Flashings shall be installed according to the manufacturers published standard details,specific details,approved by BASF Corporation and shall be submitted to the Building Official for review. 5. All work shall be performed by a Contractor licensed to do roofing/waterproofing and be a Manufacturer Trained 'Qualified Applicator' approved by BASF Corporation. BASF Corporation shall supply a list of approved applicators to the authority having jurisdiction. 6. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS I I I and the wind load requirements of applicable Building Code. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect,or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. A non-skid surfacing is required for all pedestrian areas,plaza decks or balconies. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,perimeters,and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended comers and comers). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. MasterSeal Traffic 1500 Traffic Bearing System shall not be installed over lightweight insulating concrete. 11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 6 1 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 15-0820.02 WADE Expiration Date: 08/24/20 WINITYP Approval Date: 09/10/15 Page 6 of 6