1804 Selva Grande Dr RES19-0174 Replace Stucco RESIDENTIAL PERMIT PERMIT NUMBER
RES19-0174
CITY OF ATLANTIC BEACH
ISSUED: 6/13/2019
800 SEMINOLE ROAD EXPIRES: 12/10/2019
ATLANTIC BEACH. FIL 32233
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
1804 SELVA GRANDE DR RESIDENTIAL ALTERATION REPLACE STUCCO WITH $3800.00
RESIDENTIAL SIDING
TYPE OF REALESTATE BUILDING USE
ZONING: SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
1695425002 SELVA TIERRA
CITY: STATE: ZIP:
COMPANY: ADDRESS:
COASTAL CONSTRUCTION 404 NORTH HARBOR LIGHTS DRIVE PONTEVEDRA FL 32081
COMPANY LLC
OWNER: ADDRESS: CITY: STATE: ZIP:
EAKIN LAURA MCDONELL 1804 SELVA GRANDE DR ATLANTIC BEACH I'L 32233-4526
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 4SS-0000-322-1000 0 $70.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $3S.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 4SS-0000-208-0600 0 $2.00
TOTAL: $109.00
Issued Date: 6/13/2019 1 of 2
City of Atlantic Beach APPLICATION NUMBER
Building Department (To be as d by the Building Department.)
800 Seminole Road
tlantic Beach, Florida 32233-5445 4
Phone(904)247-5826 - Fax(904)247-5845
E-mail: building-dept@coab.us Date routed: (0 9
City web-site: hftp://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
I
Property Address: I So4 SE-un Aep�artment review required Yes "'No
14 lff�ilding _-)
Applicant: R ST A C_ e 0 t__11S__.1T _Wa_nr�ing &Zoning
Tree Administrator
Project: RE M(-)VASz� 'T Q CC 0 Public Works
Public Utilities
REPLAO-C-- Lu Public Safety
Fire Services
Review fee Dept Signature
Other Agency Review or Permit Required Review or Receipt Date Q,
Florida Dept. of Environmental Protection of Permit Verified By
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ElApproved. ElDenied. [:]Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: Date: 6-1��i
TREE ADMIN. Second Review: FlApproved as revised. F V
]Denied. F]Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: []Approved as revised. [—]Denied. E]Not applicable
Comments:
Reviewed by: Date:
Revised 0511912017
Building Permit Application OFFICE COPY Updated 1019118
City of Atlantic Beach Building Department "ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
Phone: (904) 247-5826 Email: BLI'1ding-DeptPcoab.LIS IS REQUIRED.
I D,, AL__�
Job Address. /(!�C)�-( L Permit Number: R C- S C)� :7
Legal Description RE#
Valuation of Work(Replacement Cost) S_35�0(p Heated/Cooled SF Non- Heated/Cooled
• ClassofWork: EINew ElAddition 0AIteration,,�Repair �]Move -'Denno EPool --'Window/Door
• Use of existing/proposed structure(s): ElCommercial Aesidential
• If an existing structure, is a fire sprinkler system installed?: E]Yes k/No
A_
• Will tree(s)be removed in association with proposed pro ect? LYes(must submit separate Tree Removal Permit) JNo
in detail the type of work to be performed:
Florida Product Approval Z 2— for multiple products use product approval form
PropertV Owner lnfornnat�lon —1, 4 T1
N a m e LA 14t�4 d:��-0 04-P4 Address 5�274V _al� - --
City I)q-rtA-j_),T-f c State F� Zip 57-,7-3 Phone
E-M a i 1 b 4(6��__Ls_rcA-C
Owner or Agent (if Agent!pow�r of Attorney or Age�� Letter Required)
Contractor Information
Name of Companyc:c�—� 17Z-46 a6vc- 621-hual fyi Agent
:- 1 G:,L:;�Z- "'y 'Lg
Address Voq 1-,1-75 Vj2 City State-7-2- Zip .3 ,26571
Office Ph�ne 0 5 & Job Site C tact Number
State Certification/Registration # o).2 E-Mail I- Ick. ),t-)cy Ll<:�L c)�- f-CL L Lli 0
Architect Name& Phone#
Engineer's Name& Phone# _11 Z
Workers Compensation Insurer OR Exemp Expiration Date _J < 0
tX cc ;=
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation h.% 0
_ LU - in
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulatingo LI) t= Z
0 0
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, 0
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of*$5
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,a -7 cc
r8 0
there may be additional permits required from other governmental entities Such as water management districts, state agencies, U.
federal agencies. cc Z
0
OWNER'S AFFIDAVIT� I certify that all the foregoing information is accurate and that all work will be done in compliance with all,, I)- W
0 cc �
applicable laws regulating construction and zoning. VJ UJ
LIJ >. CL
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY �: W
Z3 LU Cy
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEPO U) IU
CC
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ATTORNEY BEF U
X LL
EC9 T.
�DING YOUR NOTICE OF CONI�=EM E N
ZLII�0TyLZ_--
(Signature of Owner or Agent) (Signaturei6�T®r)
Signed and sworn to(or affirmed)before melihis day of Signed and sworn to(or a ir befor mewls day of
WI'7 by 44 P�7� y
(511pat of N_ a
nat
PETER W.SCHWAB
MY C TONI CIlqr)Lr ERGE.
ersonal OMMISSION#FF 246243 Personally Known OR SPERGE
Sl()N F-924951
>1 �Procluce z 10 EXPIRES:July 10,2019 Produced identification co%Amls r
60ricled Thru Notary Pu 6,2111,
Type of Identification: cypiAFS�Oct0h
Type of Ide - I-
,VL�A OFFICE COPY
Florida Product Approval
HardiePlankO Lap Siding
• For use inside HVHZ:
o HardiePlank Lap Siding fastener types, fastening schedule, and installation
shall be in accordance with the Miami-Dade County Florida NOA 17-
0406.06. Consult the HardiePlank product installation instructions on the
follow pages for all other installation requirements.
• For use outside of HVHZ,
o HardiePlank Lap Siding fastener types, fastening schedule, and installation
shall be in accordance with Engineering Evaluation Reports RIO-2683-17,
RIO-2687-17, or RIO-2688-17. Consult the HardiePlank product
installation instructions on the follow pages for all other installation
requirements.
®R
HardiePlank- "MM, Lap Siding JamesHardie
EFFECTIVE MAY 2016�
INSTALLATION REQUIREMENTS - PRIMED&COLORPLUSc` PRODUCTS Visit wvvw,hardieinstallation.com for the most recent version.
SELECT CEDARMILL' e SMOOTH 9 CUSTOM COLONIAL'"SMOOTH e CUSTOM COLONIAL" ROUGHSAWN
CUSTOM BEADED CEDARMILL'9 CUSTOM BEADED SMOOTH 9 STRAIGHT-EDGE SHINGLE PLANK
IMPORTANT FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN
APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE,VIOLATE LOCAL BUILDING CODES,AND VOID THE
PRODUCT ONLY WARRANTY.BEFORE INSTALLATION,CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE'PRODUCT INSTRUCTIONS.
INSTALLATION OF HZ11 00 PRODUCTS OUTSIDE AN HZ1 08 LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE Tm
APPLIES TO YOUR LOCATION,VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343(866 9HARDIE)
STORAGE& HANDLING: CUTTING INSTRUCTIONS
Store flat and keep dry and covered prior OUTDOORS INDOORS
to installation.installing siding wet or 1.Position cutting station so that wind will blow dust away from user 1.Cut only using score and snap,or shears(manual,electric or pneumatic).
saturated may result in shrinkage at butt and others in working area. 2.Position cutting station in well-ventilated area
2.Use one of the following methods:
joints.Carry planks on edge. Protect a.Best: i.Score and snap
edges and corners from breakage.James ii.Shears(manual,electric or pneumatic) -NEVER use a power saw indoors
Hardie is not responsible for damage b.Better: i.Dust reducing circular saw equipped with a -NEVER use a circular saw blade that does not carry the HarclieBlacle saw blade trademark
caused by improper storage and handling HardieBlade'saw blade and HERA vacuum extraction -NEVER dry sweep—Use wet suppression or HEPA Vacuum
c.Good: i.Dust reducing circular saw with a HardieBlacle saw blade
of the product. (only use for low to moderate cutting)
Important Note:For maximum protection(lowest respirable dust production),James Hardie recommends always using"Best"-level cutting methods where feasible.
NIOSH-approved respirators can be used in conjunction with above cutfing practices to further reduce dust exposures.Additional exposure information is available
at www.jameshardie.com to help you determine the most appropriate cutting method for your job requirements.If concern still exists about exposure levels or you
do not comply with the above practices,you should always consult a qualified industrial hygienist or contact James Hardie for further information. M3105
GENERAL REQUIREMENTS:
HardiePlank'lap siding can be installed over braced wood or steel studs spaced a maximum of 24 in.D.C.or directly to minimum 7/16 in.thick OSB
sheathing.See general fastening requirements.Irregularities in framing and sheathing can mirror through the finished application.
Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www. ameharclie.com
A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with
penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration.
James Hardie does manufacture HardieWrap�Weather Barrier,a non-woven non-pel1orated housewrap',which complies with building code requirements.
When installing James Hardie products all clearance details in figs.3-14 must be followed.
Adjacent finished grade must slope away from the building in accordance with local building codes-
typically a minimum of 6 in.in the first 10 ft.. Figure 1 Double Wall Single Wall
Do not use HardiePlank lap siding in fascia or trim applications. Construction Construction
Do not install James Hardie products,such that they may remain in contact with standing water water-resistive barrier let-in bracing
HardiePlank lap siding may be installed on flat vertical wall applications only. plywood or 24 in.o.c.max.
For larger projects,including commercial and multi-family projects,where the span of the OSB sheathing
wall is significant in length,the designer and/or architect should take into consideration the
coefficient of thermal expansion and moisture movement of the product in their design.
These values can be found in the Technical Bulletin"Expansion Characteristics of
James Hardie�Siding Products"at www,JamesHardie.com.
DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie',Products.
INSTALLATION: JOINTTREATMENT
One or more of the following joint treatment options Figure 2 Nail line(If nail
line is not
are required by code(as referenced 2009 IRC stud present place
R703,10.2) fastener
A.Joint Flashing(James Hardie recommended) between 3/4
in.&1"from
B.Caulking*(Caulking is not recommended water- '0
resistive Nail 318 in.from top of plank)
for ColorPlus for aesthetic reasons as the barrier edge of plank
Caulking and ColorPlus will weather joint water-resistive
differently.For the same reason, flashing
barrier
do not caulk nail heads on 0000
HardieZone" fastener
ColorPlus products.) HardiePlank'siding 0 0 0 Install a 1 1/4 in.starter strip to
C."H" jointer cover install planks in 00 ensure a consistent plank angle
moderate contact at butt joints
leave appropriate gap between planks and trim,then caulk
Note:Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus. *Refer to Caulking section in these instructions.
For additional information on HardieWrap"Weather Barrier,consult James Hardie at 1-866-4Hardie or www.hardiewrap.com
WARNING:"01113 BREATHING SILICA DUST
James Hardie,products contain respirable Mstallne silica,which is known to the State of California to cause cancer and is considered by IARC and NOSH to be a cause of cancer from some occupational
sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis,and has been linked with other diseases. Some studies suggest
smoking may increase these risks. During installation or handling:(1)work in outdoor areas with ample ventilation;(2)use fiber cement shears for cutting or,where not feasible,use a HarclieBlade�saw blade
and dust-reducing circular saw attached to a HEPA vacuum;(3)warn others in the immediate area;(4)wear a properly-fitted,NIOSH-approved dust mask or respirator(e.g.N-95)in accordance with applicable
government regulations and manufacturer instructions to further limit respirable silica exposures. During clean-up,use HEPAvacuums or wet cleanup methods-never dry sweep. For further information,refer
to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE(1-800-942-7343). FAILURE TO ADHERE TO OUR WARNINGS,MODS,AND
INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH.
HS11119-Pl/4 05/16
=91Z
CLEARANCE AND FLASHING REQUIREMENTS
Figure 3 Figure 4 Figure 5 Figure 6
Roof to Wall Horizontal Flashing Kickout Flashing Slabs, Path, Steps to Siding
Z-Flashing A As requirt-c
r by IRC f 16
min4 in 4 i��
.19
Min.1/4 in.
in / in
Do not caulk,
in.
L 2 in.
in. in.
Figure 7 Figure 8 Figure 9 Figure 10 Figure 11
f%
Deck to Wall Ground to Siding GLI'L't6r to Siding Sheltered Areas Mortar/Masonry
L-Flashing
7-Flashing
Z-Fla hing Z- 1whing
7 Allashm
g
Min.
1 in. Min.1/4 in.
6 Zin.
In.
in in.
Min.1/2 in.
Figure 12 Figure 13 Figure 14
Drip Edge Block Penetration Valley/Shingle Extension
(Recommended in HZIQ)
Z-F
kin. Y4
mitcaulk
FASTENER REQUIREMENTS
Blind Nailing is the preferred method of installabon for HardiePlanke lap siding products.Face nailing should only be used where required by code for high wind
areas and must not be used in conjunction with Blind nailing(Please see JH Tech bulletin 17 for exemption when doing a repair).Pin-backed corners may be
done for aesthetic purposes Only.Pin-backs shall be done with finish nails only,and are not a substitute for blind or face nailing.
BLIND NAILING FACE NAILING
Nails-Wood Framing Nails-Wood Framing
*Siding nail(0.09 in.shank x 0.221 in.HD x 2 in.long) e 6d(0.113 in.shank x 0.267 in.HID x 2 in.long)
* 11 ga.roofing nail(0.121 in.shank x 0.371 in.HID x 1.25 in.long) e Siding nail(0.09 in.shank x 0.221 in.HID x 2 in.long)
Screws-Steel Framing Screws-Steel Framing
-Ribbed Wafer-head or equivalent(No.8 x 1 1/4 in.long x 0.375 in.HD)Screws 9 Ribbed Bugle-head or equivalent(No.8-18 x 1-5/8 in.long x
must penetrate 3 threads into metal framing. 0.323 in.IHID)Screws must penetrate 3 threads into metal framing.
Nails-Steel Framing Nails-Steel Framing
*ET&F Panelfast'nails or equivalent(0.10 in.shank x 0.313 in.HID x 1-1/2 in. ET&F pin or equivalent(0.10 in.shank x 0.25 in.HID x 1-1/2 in.long)
long) Nails must penetrate minimum 1/4 in.into metal framing.
Nails must penetrate minimum 1/4 in.into metal framing. OSIB minimum 7/16 in.
0S13 minimum 7/16 in. e Siding nail(0.09 in.shank x 0.221 in.HID x 1-1/2 in.long)*
11 ga.roofing nail(0121 in.shank x 0.371 in.HD x 1.75 in.long) 24 inr----'
Ribbed Wafer-head or equivalent(No.8 x 1 5/8 in.long x 0.375 in.HD). stud O.C.max.
Stud 2,V
O.C.max 1/4 in.min.
Figure 15 Figure 16 overlap
Minimum overlap
for Both Face
Nail Line/
and Blind Nailing
_J_
3/4 in.-i iri.
Blind Nail —n
face nail
min.1 1/4 in.
o P
veldap
twater-resistive
Water Resistive barrier
1 1/4"min. Barrier
Overlap Laminate sheet to be removed immediately after installation of each course for ColorPlusO products.
When face nailing to OSB,planks must be no greater than 9 1/4 in.wide and fasteners must be 12 in.o.c.or less.
**Also see General Fastening Requirements;and when considering alternative fastening options referto James HardieTechnical Bulletin USTB 17-FasteningTips for HardiePlane Lap Siding.
HS11119-P2/4 05/16
AZZ)
GENERAL FASTENING REQUIREMENTS PNEUMATIC FASTENING
Fasteners must be corrosion resistant,galvanized,or stainless steel. James Hardie products can be hand nailed or fastened with a pneumatic tool.
Electro-galvanized are acceptable but may exhibit premature corrosion. Pneumatic fastening is highly recommended. Set air pressure so that the
James Hardie recommends the use of quality,hot-dipped galvanized nails. fastener is driven snug with the surface of the siding.A flush mount
James Hardie is not responsible for the corrosion resistance of fasteners. attachment on the pneumatic tool is recommended. This will help control the
Stainless steel fasteners are recommended when installing James Hardie' depth the nail is driven.If setting the nail depth proves difficult,choose a
products near the ocean,large bodies of water,or in very humid climates. setting that under drives the nail. (Drive under driven nails snug with a
smooth faced hammer-Does not apply for installation to steel framing).
Manufacturers of ACQ and CA preservative-treated wood recommend spacer
materials or other physical barriers to prevent direct contact of ACQ or CA
preservative-treated wood and aluminum products.Fasteners used to attach countersunk,
HardieTrim Tabs to preservative-treated wood shall be of hot dipped fill&add nail
zinc-coated galvanized steel or stainless steel and in accordance to 2009 IRC snug flush DO NOT DO NOT
R317.3 or 2009 IBC 2304.9.5, Figure A Figure B under drive nails staple
• Consult applicable product evaluation or listing for correct fasteners type
and placement to achieve specified design wind loads, PAINTING
• NOTE:Published wind loads may not be applicable to all areas where Local DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardiee
Building Codes have specific jurisdiction.Consult James Hardie Technical Products.James Hardie products must be painted within 180 days for primed
Services if you are unsure of applicable compliance documentation. product and 90 days for unprimed.100%acrylic topcoats are recommended.
• Drive fasteners perpendicular to siding and framing. Do not paint when wet.For application rates refer to paint manufacturers
Fastener heads should fit snug against siding(no air space).(fig.A specifications.Back-rolling is recommended if the siding is sprayed.
Do not over-drive nail heads or drive nails at an angle.
If nail is countersunk,fill nail hole and add a nail.(fig.B) CUT EDGE TREATMENT
For wood framing,under driven nails should be hit flush to the plank with a Caulk,paint or prime all field cut edges.James Hardie touch-up kits are
hammer(For steel framing,remove and replace nail). required to touch-up ColorPlus products.
NOTE:Whenever a structural member is present,HardiePlank should be
fastened with even spacing to the structural member.The tables allowing CAULKING
direct to OSB or plywood should only be used when traditional framing is For best results use an Elastomeric Joint Sealant complying with ASTIM C920
not available. Grade NS,Class 25 or higher or a Latex Joint Sealant complying with ASTM
Do not use aluminum fasteners,staples,or clipped head nails. C834.Caulking/Sealant must be applied in accordance with the
caulking/sealant manufacturer's written instructions.Note:OSI Quad as well
as some other caulking manufacturers do not allow tooling.
COLORPLUS"TECHNOLOGY CAULKING,TOUGH-UP& LAMINATE
•Care should be taken when handling and cutting James Hardieg ColorPlus(b products.During installation use a wet soft cloth or soft brush to gently wipe off any
residue or construction dust left on the product,then rinse with a garden hose.
•Touch up nicks,scrapes and nail heads using the ColorPlusO Technology touch-up applicator.Touch-up should be used sparingly.
If large areas require touch-up,replace the damaged area with new HardiePlank,lap siding with ColorPlus Technology.
•Laminate sheet must be removed immediately after installation of each course.
•Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPlus'product dealer.
•Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer.
Note:James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be
covered under the James Hardie ColorPlus Limited Finish Warranty.
PAINTING JAMES HARDIE" SIDING AND TRIM PRODUCTS WITH COLORPLUS11 TECHNOLOGY
When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application:
• Ensure the surface is clean,dry,and free of any dust,dirt,or mildew
•Repriming is normally not necessary
• 100%acrylic topcoats are recommended
•DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie',Products.
•Apply finish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature
•DO NOT caulk nail heads when using ColorPlus products,refer to the ColorPlus touch-up section
HS11119-P3/4 05/16
"MME 10
COVERAGE CHARPESTIMATING GUIDE
Number of 12 ft.planks,does not include waste
COVERAGE AREA LESS OPENINGS HARDIEPLANKO LAP SIDING WIDTH
SQ 51/4 61/4 7114 71/2 8 81/4 91/4 91/2 12
(1 So=100 sq.ft.) (exposure) 4 5 6 61/4 63/4 7 8 81/4 103/4
1 25 20 17 16 15 14 13 13 9
2 50 40 33 32 30 29 25 25 19
3 75 60 50 48 44 43 38 38 28
4 100 80 67 64 59 57 50 50 37
5 125 100 83 80 74 71 63 63 47
6 150 120 100 96 89 86 75 75 56
7 175 140 117 112 104 100 88 88 65
8 200 160 133 128 119 114 100 100 74
9 225 180 150 144 133 129 113 113 84
10 250 200 167 160 148 143 125 125 93
11 275 220 183 176 163 157 138 138 102
12 300 240 200 192 178 171 150 150 112
13 325 260 217 208 193 186 163 163 121
14 350 280 233 224 207 200 175 175 130
15 375 300 250 240 222 214 188 188 140
16 400 320 267 256 237 229 200 200 149
17 425 340 283 272 252 243 213 213 158
18 450 360 300 288 267 257 225 225 167
19 475 380 317 304 281 271 238 238 177
20 500 400 333 320 296 286 250 250 186
This coverage chart is meant as a guide.Actual usage is subject to variables such as building design.James Hardie does not assume responsibility
for over or under ordering of product.
RECOGNITION:In accordance with ICC-ES Evaluation Report ESR-2290,HardiePlank@ lap siding is recognized as a suitable alternate to that specified in:the 2006,2009,&2012 International Residential Code for One-
and Two-Family Dwellings,and the 2006,2009,&2012 International Building Code,.HardiePlank lap siding is also recognized for application in the following:City of Los Angeles Research Report No.24862,State of
Flodda listing FL#889,Dade County,Florida NOA No.02-0729.02,U.S.Dept.of HUD Materials Release 1263c,Texas Department of Insurance Product Evaluation EC-23,City of New York MEA 223-93-M,and Califomia
DSA PA-019.These documents should also be consulted for additional information concerning the suitability of this product for specific applications.
0 2016 James Hardie Building Products. All rights reserved. Additional Installation Information,
TM,SM,and 0 denote trademarks or registered trademarks of
James Hardie Technology Limited.2'-*,is a registered trademark Warranties,and Warnings are available at
of James Hardie Technology Limited. www.jameshardie.com JamesHardie
Panelfast is a registered trademark of ET&F Fastening Systems,Inc.
HS11119-P4/4 05/16
'))—dIlJr C4 r.--le,�-z 6-,�A-> Doc#2019130540 OR BK 18815 Page 1879
--7 1�-7- 55 Lf`5- Number Pages 1
Recorded 0605,2019 11 27 AM
RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL
NOTICE OF COMMENCEMENT COUNTY
SCANNL,-:-D RECORDING $1000
F) Dp r-,-1
state of I urr Tax Folio Nu.
County of Da Y4�, -D a te:—kN1—q
To Whom It May Concern:
The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713
of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT.
Legal Descript* of property being improved: L-) K-2 0/Zr/-,4 97-J,-tk-177 C-
76 Z L,Y'
Address of property being improved: Is N bit I va-GT-cLNo),-e'--�
General description of improvements:
/-Owner:
Owner's interest in site of the improvement:
,)(.Fee Simple Titleholder(if other than owner):
Name:
Contractor- (.,C�rL4,4 -J=P T-jjk?,k C 7-14�k 3
-7-7
Address: V AJ - 09�W)6,--Ve z D-0
Telephone No.: FaxNo:
Surety(if any)
Address: AMOUnt of Bond 5
Telephone No: Fax No:
Name and address of any per on making a loan for the construction of the improvements
Name:- A ;
Address:
Phone No: Fax No-
Name of person within the Stati of Florida,other than himself,designated by owner upon whorn notices or other documents may
be served:Name 1P
Address:
Telephone No: Fax No:
In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section
713.06(2)(b).Florida Stat (jillin at Owner's option)
Name
Address
Telephone No: Fax No:
Expiration clate of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is
specified):
THIS SPACE FOR RECORDER'S USE ONLY OWNE
1211A(J-
logned V%.'a"
nth ounty of Duval.State
Of Florida.has personally Ppe*A
Notap V Publit at Las ge.Stal I F Int rrv7rl
PETER W.SCMAB
My commission expires
1-! MY COAUSSION FF246243
EXPIRES:July 10.2019 PersonAIV Known or
Borided Thru Nctin Puw und&-w" Produced Idpritification