Loading...
695 Atlantic Blvd ROOF19-0057 TPO Re-Roof ROOF NON SHINGLE PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROOF19-0057 \ v 800 SEMINOLE ROAD ISSUED: 7/1/2019 ATLANTIC BEACH, FL 32233 EXPIRES: 12/28/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORMTO THE CURRENT 6TH EDITION1 OF • ' ! BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB-ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 695 ATLANTIC BLVD ROOF NON SHINGLE TPO re-roof-41 squares $37476.00 TYPE OF ZONING: : ! • • • GROUP: 170656 0000 SALTAIR SEC 01 COMPANY: ADDRESS: STONEBRIDGE 6956 PHILLIPS PARKWAY DR N JACKSONVILLE FL 32258 CONSTRUCTION • ADDRESS: SOLOMON PROPERTIES 14255 BEACH BLVD JACKSONVILLE FL 32250 INC WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF . ! Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $240.00 BUILDING PLAN CHECK 4SS-0000-322-1001 0 $120.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.40 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.60 TOTAL: $369.00 Issued Date: 7/1/2019 1 of 2 s!,APJjy�� City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) r800 Seminole Road V O F{1 /a ` r-, -9 -N Atlantic Beach, Florida 32233-5445 t _t W T Phone(904)247-5826 • Fax(904)247-5845JJ C �rVA �r E-mail: building-dept@coab.us Date routed: l O City web-site: http://vmw.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: (� q X:'la/rkc 6Q, , Department review required Yes N Buildi Applicant: S )(�Q_bri(� C �,`"' ! Planning &Zoning Tree Administrator Project: _-p (�—((�y F �-{ Sit t-t�-t(.CS Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. []Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denie ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 0FR - f r Building Permit Application Updated 12/8/17 * ' City of Atlantic Beach " BVI 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 ,� Job Address: 695 Atlantic Blvd Atlantic Beach, FL ��AA 32233 Permit Number: OF (Vl (DOS- Legal Description 10-820-2S-29E.255 SALTAiR SEC 1 LOTS 751,752.771,W 3FT LOT 772(EX PT RECD O,9 9430-138 PARCEL 6) RE# 170656-0000 Valuation of Work(Replacement Cost)$ 37,476.00 Heated/Cooled SF 4096 Non-Heated/Cooled 412 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Roof Replacement 41 sq Flat pitch using GAF TPO Florida Product Approval# FL5293 for multiple products use product approval form Property Owner Information Name; Solomon Properties Inc Address: 14255 Beach Blvd city Jacksonvile BeachState FL Zip 32250 Phone `(f_" { — } C' E-Mail �L'��.;i��lrr) 5hL �'_ rrt 0 V- Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: Stonebridge Construction Services LLC Qualifying Agent: Brian Vick Address 6956 Philips Parkway Dr N city Jacksonville State FL Zip 32256 Office Phone 904-262-6636 Job Site/Contact Number Chris Reagan /904-463-8217 State Certification/Registration# CCC1328917 E-Mail jennifer@stonebridgebuilt.eom Architect Name&Phone# Engineer's Name&Phone# �� Workers Compensation Bridgefield Casualty Ins Co 05/16/20 N Exempt/Insurer/Lease Employees/Expiration Date Z Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or instal lationgso Z — commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulatigrs I j - p construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,Q M p = h WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc, NOTICE;In addition to the requirements of9ls(a a U permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,a P Q o there may be additional permits required from other governmental entities such as water management districts, state agenciesar<Z p d federal agencies. U J LL, y ~ W OWNER'S AFFIDAVIT; I certify that all the foregoing information is accurate and that all work will be done in compliance with ale < Z applicable laws regulating construction and zoning. U. U_ CJ LU w } WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY 1-11 . H w � ❑ RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND 5 in w TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE > RECO I YOUR NOTICE OF COMMENCEMENT. tr Cr (Signature of Owner or Agent) (Signature of Contractor) (including contractor) Signed and sworn to (or affirmed)before me this 12th day of Signed and sworn to (or affirmed) before me this 12th day of June 201�by Doug Solomon June 2019 by Brian Vick tgnature of Notary) (SIlVature of otary 1:411W^.P_1^V14 [ ]Personally Known OR i%Y=nnh ic State of Florida [ Personally Known OR ejlR °`• Notary Public State of Florida (X)Produced Identification i n Schlachter Jennifer Lynn Schlachter Type of Identification: DTIV 5sion GG 109644 [ Produced Identification } n My Commission GG 109844o11nnr1 T e of Identification: {- f'F ;,toa Expires 05/31/2021 Doc # 2019139839, OR BK 18828 Page 2227 , Number Pages : 1, Recorded 06/14/2019 01 : 42 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10 . 00 OFFICE COPY NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE) Permit No.(2pio,F/9- S7� Tex Folio No. 170656-0000 State of pil County of DUVAL To whom It may concern: The undersigned hereby Informs you that Improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal description of property being Improved: 10-820-2S-29E255 SALTAIR SEC 1 LOTS 751,752,771,W 3PP LOT 772(EX PT RECD 0/119430-138 PARCEL 6) Address of property being improved: 695 Atlantic Blvd Atlantic Beach,FL 32233 General description of Improvements: Roof Replacement Owner Solomon Properties Inc Address 14255 Beach Blvd Jacksonville,FL 32250 Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor Stonebridge Construction Services LLC Address 6956 Phillips Parkway Dr N Jacksonville,FL 32256 Phone No.934-262-M6 Fax No.904-262-2247 Surety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself or herself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself or herself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: DATE 0612.19 o Before maiNs r4lh day of J,na 2019 in the c'— County of Duval,State of Florida,has personalty appeared '" 3 m Doug Solomon herein try 3,.�v himself/herself and affirms thal all statements and d tions herein "3 ar a and accurate _ 0 rn o� � N s SL Notary P lie at Lnrge.State of � .County of A � My commission expires: Personal) Known or Produced yldenli ication auvnrsursaa ARCHITECTURAL • • 1 , 1 DRAWINGS EverGuar&'TPO/PVC Architectural Roofing Details Manual ,� ROOF PROJECTION O ' " 3q r.0'4 EVERGUAREP COATED METAL VERGUARDa POURABLE SEALANT QUICK-SET NON-SHRINK GROUT EVERGUARD®UNIVERSAL CORNER OR UNREINFORCED CORNER. 4"(102 mm)FLANGE WITH HEMMED EDGE FASTENED 12" (305 mm)O.C.W/DRILL-TEC" �/ FASTENERS OR MIN.4 PER BOX. HEAT-WELDED LAP(SEE NOTE#5) j/ EVERGUARD®6"(152 mm)WIDE FLASHING STRIP HEAT-WELDED REINFORCED EVERGUARD® MEMBRANE O ENERGYGUAR6'ROOF INSULATION NOTE: ROOF DECK/SUBSTRATE 1.FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY. 2.BEND EVERGUARD®COATED METAL TO FORM A SEALANT BOX AS SHOWN.STRIP-IN VERTICAL SEAM WHERE BOX IS JOINED TOGETHER. 3.ALLOW 2"(52 mm)CLEARANCE AROUND THE PROJECTION.IF MULTIPLE PROJECTIONS,ALLOW 1"(25.4 mm) BETWEEN PROJECTION AND BOX. 4.INSIDE SURFACE OF EVERGUARD®COATED METAL SEALANT BOX(BARE METAL SIDE)MUST BE CLEAN AND DRY BEFORE SEALANT IS APPLIED. 5.EXISTING PROJECTION MUST BE CLEANED AND FREE OF ANY INSULATING MATERIALS. 6.25 YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES. 7.APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). DR—NG y THIS DETAIL APPLIES TO. rcl 509 COATED METAL SEALANT BOX ALL SYSTEMS ROOF PENETRATION PENETRATION FLASHING SERIES www.gaf.com SCALE REVISION DATE 1C. oma. P✓"4Pa"Y.HJ07 sa N.T.S. 12-12-17 138 ARCHITECTURAL DRAWINGS EverGuard I TPO/PVC Architectural Roofing Details Manual REINFORCED EVERGUARD® MEMBRANE FIELD SHEETS (NOT TO SCALE) : ....: :.... :.:.rr:........ ...;r.... .................................................... :':C F ......}....}: .. :})as ...................................................... :: : ............ ...T•...... ................ .............. ..................................................... ::::.:::......:. .::::::.: : ' ................................................ ............................ . ......: .... ::.;r:... ::::: ....... ... ::: ::::::::::............ ............................ ir: �.-:r:rirrrrr: .�: ................................. ..... :............ ..... ... ..... ....... .............:::::::::::::::: ...✓ r ::::::: ::::::......:: : :�'::: .....:::: ... •:::::e:�:•:: ::. :.:. . ............................... .:.......... ....................................... . ................................................. ............................ ;;:r: :: : . ... .......... ....... ....... ................ ........... 6"(152 mm) FOR TPO OR FOR PVC REINFORCED EVERGUARD®MEM BRAN E HEAT-WELDED LAP(SEE NOTE#1) EVERGUARD®CUT EDGE SEALANT ENERGYGUARD`NROOF INSULATION DRILL-TEC'PLATES&SCREWS 12"(305 mm)O.C.MAX(SEE DETAIL 116 (SEE DETAIL 116) ROOF DECKISUBSTRATE NOTE: 1.FOR HEAT-WELDING LAPS USE 1.5"MAX(25.4 mm) WELD WITH MACHINE AUTOMATIC WELDER AND 1.5"(127 mm)WELD WITH HAND WELDER. 2.FOR INSULATION THICKNESS GREATER THAN S"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY. 3.APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). ® DRAWING k THIS DETAIL APPLIES TO: rd- 102A SIDE LAP DETAIL Mechanically FIELD OF ROOF Attached Systems SERIES wvnv.g.f.com SCALE REVISION DATE I Gamp�s DMe. P,N,p,y.NJ 0741 N.T.S. 6-20-16 25 ARCHITECTURAL DETAIL DRAWINGS EverGuard TPO/PVC Architectural Roofing Details Manual FLASHING KEY Flashing Sheets that are... •24"or less-loose laid •Greater than 42"-bonding adhesive required FASTEN CLIP 12"(305 mm)O.Cj p I • COPING CAP BACK SIDE r: ::>: i:::......?ii::. BONDING t. EVERGUAREP O G ADHESIVE (SEE FLASHING KEY) `::. ':'' ii:::isisis?: DRILL-TEC'"PLATES&SCREWS 12"(305 mm) O.C. 6" ] mm 152 O.C.FOR BALLASTED [ SYSTEMS HEAT-WELDED LAPSEE NOTE#3 ( ) REINFORCED EVERGUARD MEMBRANE 8" 203 mm :: :>:>,.rt: :>: : : `:`;::<> .... ( .......:............:.. In. >.:;r :;:' :i iiis:>:->:i:`;;>::;;r�....... ......................... =_ : ENERGYGUARD14 ROOF INSULATION • ROOF DECK/SUBSTRATE WOOD NAILER,5/4"(38.1 mm)x 4" (102 mm)MIN.WIDE SECURED TO DECK(OPTIONAL) ALTERNATE BASE REFER TO EVERGUARD DETAIL 307 0 ',r NOTE: 1.FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICALLY FASTENED SYSTEMS ONLY. 2.IF EVERGUARD®FREEDOM'"MEMBRANE IS USED,BONDING ADHESIVE IS NOT NEEDED AND WALL MUST BE PRIMED. 3.APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). 4.FOR SELF-ADHERED RAPIDSEAMTm TECHNOLOGY SYSTEMS,SEE EVERGUARD® DETAIL 330 FOR LAP APPLICATION. ® DRAWING b THIS DETAIL APPLIES TO: 303 WALL CAP DETAIL ALL SYSTEMS PARAPET WALL& CURB SERIES wvhv.ydf.COm SCALE REVISION DATE I roapmpY rs - N o,os, N.T.S. 12-12-17 76 ARCHITECTURAL , i DRAWINGS EverGuardRoofing Details Manual FLASHING KEY •24"-54"(610 mm-1.37 m) EVERGUARD®WATER BLOCK OR REQUIRES BONDING ADHESIVE FLEXSEAL`"CAULK GRADE SEALANT •UP TO 24"(610 mm)DRY HUNG FLEXSEAL`CAULK GRADE SEALANT DRILL-TEC'TERMINATION BAR FASTENED 12"(305 mm)O.C.W/DRILL-TEC"FASTENERS CAULKING BY OTHERS 1 REGLET OF SURFACE-MOUNT COUNTERFLASHING BY OTHERS (REQUIRED FOR EXTENDED-LENGTH a mmIMIN. GUARANTEE) EVERGUARD®BONDING ADHESIVE (SEE FLASHING KEY) DRILL-TEC"PLATES&SCREWS 12" 305 mm 6152 mm ( )O.C.( " )O.C.FOR BALLASTED SYSTEMS HEAT-WELDED LAP REINFORCED EVERGUARD MEMBRANE 8 ( in. ENERGYGUAR6'ROOF INSULATION ROOF DECK/SUBSTRATE WOOD NAILER,5/4"(31.8 mm)x 4"(102 mm) MIN.WIDE SECURED TO DECK(OPTIONAL) ALTERNATE BASE REFER TO DETAIL 307 0 NOTE: 1.FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICALLY FASTENED SYSTEMS ONLY. 2.EXISTING REGLET IS ACCEPTABLE IF METAL IS IN GOOD CONDITION. 3.IF EVERGUARD®FREEDOM'"MEMBRANE IS USED,BONDING ADHESIVE IS NOT NEEDED AND WALL MUST BE PRIMED. 4.FOR SELF-ADHERED RAPIDSEAMTm TECHNOLOGY SYSTEMS,SEE EVERGUARD®DETAIL 330 FOR LAP APPLICATION. 5.APPLY EVERGUARD TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). DRANANG k THIS DETAIL APPLIES TO: PARAPET WALL FLASHING WITH PARAPET WALL& 301 COUNTERFLASHING ALL SYSTEMS CURB SERIES wwu.gaf.GOm SCALE REVISION DATE c"mv:ome. Pz vpo N,07054 N.T.S. 6-20-16 74 ARCHITECTURAL , i DRAWINGS EverGuard,TPO/PVC Architectural Roofing Details Manual • R.T.U. • DRILL-TEC'FASTENERS 12"(305 mm)O.0 MAX WOOD NAILER METAL COUNTERFLASHING OR SLIP FLASHING BY OTHERS 3"(76.2 mm)MIN.FACE. INSULATED METAL CURB ENERGYGUARDN ROOF INSULATION WOOD NAILER,5/4"(38.1 mm)x 4"(102 mm) MIN.(OPTIONAL) REINFORCED EVERGUARD® MEMBRANE DRILL-TEC"FASTENERS 12"(305 mm)O.C. HEAT-WELD REINFORCED EVERGUARD®MEMBRANE DRILL-TEC FASTENERS 12"(305 mm)O.C.OR 8"O.C.(203 mm)FOR BALLASTED ENERGYGUARD"ROOF INSULATION ROOF DECK/SUBSTRATE REFERENCE EVERGUARD° PARAPET WALL&CURB FLASHING DETAILS(300 SERIES) FOR BASE TERMINATION NOTE: 1.FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED. 2.FOR SELF-ADHERED RAPIDSEAMT' TECHNOLOGY SYSTEMS,SEE EVERGUARD®DETAIL 330 FOR LAP APPLICATION. 3.IF EVERGUARD®FREEDOMT"MEMBRANE IS USED,BONDING ADHESIVE IS NOT NEEDED AND WALL MUST BE PRIMED. 4.APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). DRAWING 9 THIS DETAIL APPLIES TO'. !��!ara 5038 TERMINATION AT EXISTING R.T.U. ALL SYSTEMS ROOF PENETRATION WITH COUNTERFLASHING DETAIL SERIES www.gaf.com Canpus Dew. SCALE REVISION DATE Pa«aoa,v NJ 07— N.T.S. 6-21-16 133 ARCHITECTURAL , 1 DRAWINGS EverGuard TPO/PVC Architectural Roofing Details Manual REFERENCE EVERGUARD® 300 SERIES PARAPET WALL AND CURB DETAILS FOR TERMINATION EVERGUARD®WATER BLOCK OR FLEXSEAL CAULK GRADE SEALANT EVERGUARD® FLEXSEAL" CAULK GRADE SEALANT ON ALL EDGES AND FASTENER HEADS DRILL-TECTM TERMINATION BAR FASTENED 6"(152 mm)O.C.W/ DRILL-TEC' FASTENERS REINFORCED EVERGUARCP MEMBRANE METAL EDGING(REFER TO EVERGUARD®200 SERIES DETAILS) REINFORCED EVERGUARD® MEMBRANE(PERIMETER SHEET IF REQUIRED) ENERGYGUARD'°ROOF INSULATION ROOF DECK/SUBSTRATE WOOD NAILER 5/4"(38.1 mm)x 4"(102 mm)MIN.SECURED TO DECK NOTE 1.FLEXSEAL'"CAULK GRADE SEALANT IS TO BE ADDED TO ALL TERMINATION BAR EDGES,OPEN HOLES, AND DRILL-TEC" FASTENER HEADS. 2.FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY. 3.IF EVERGUARD®FREEDOMT'MEMBRANE IS USED,BONDING ADHESIVE IS NOT NEEDED AND WALL MUST BE PRIMED. 4.FOR SELF-ADHERED RAPIDSEAM' TECHNOLOGY SYSTEMS,SEE EVERGUARD®DETAIL 330 FOR LAP APPLICATION. 5.APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO DETAIL EVERGUARD®115). DRAWING# THIS DETAIL APPLIES TO: WALL EDGE FLASHING WITH Adhered Systems System F.. 313 Mecha Brallyled Attached Systems PARAPET WALL& TERMINATION BAR DETAIL Self-Adhered Systems CURB SERIES wWw.gaf.wm SCALE REVISION DATE 1C ZDZ* P"Avmr.NA 0706 N.T.S. 12-12-17 85 ALTERNATE INSTALLATION EVERGUARD®PREMOLDED VENT BOOT ......... TARGET z sz mrt;r... TARGET MADE FROM EVERGUARD® TPO MEMBRANE -2 2 mm}:. z STAINLESS STEEL CLAMP == = VENT STACK FLEXSEA( CAULK GRADE SEALANT SEE NOTE #2 EVERGUARD®WATER BLOCK OR FLEXSEA17CAULK GRADE SEALANT EVERGUARD®PREMOLDED VENT BOOT DRILL-TEO PLATES&SCREWS 4 PER PENETRATION HEAT-WELDED LAP REINFORCED EVERGUARD® MEMBRANE n ENERGYGUARD ROOF INSULATION ROOF DECK/SUBSTRATE NOTE: 1. DO NOT CUT SIDE OF PREMOLDED BOOT. IT MUST BE PULLED OVER VENT PIPE. 2. IF THE PLATES AND FASTENERS INTRUDE INTO BOOT FLANGE AREA, THEN A TARGET MUST FIRST BE INSTALLED OVER PLATES AND FASTENERS BEFORE BOOT INSTALLATION. 3. FOR INSULATION THICKNESS GREATER THAN 8"(203 mm), A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY. 4. 25 YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES 5.APPLY EVERGUARD® TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). DRAWING# THIS DETAIL APPLIES TO, rerGuard 506A PREMOLDED VENT BOOT ROOF PENETRATION FLASHING DETAIL ALL SYSTEMS SERIES W Ww.gaf.00m SCALE REVISION DATE t Campus Drive. Parsippany,NJ 0]054 N.T.S. 6-21-16 CONTINUOUS PENETRATION EVERGUARD®PREMOLDED SPLIT PIPE BOOT FLEXSEAC CAULK GRADE SEALANT EVERGUARCP WATER-BLOCK OR FLEXSEAI! UNDER METAL BAND HEAT WELDED LAP EVERGUARD® REINFORCED MEMBRANE ENERGYGUARD ROOF INSULATION ROOF DECK/SUBSTRATE NOTE: 1. FOUR DRILL-TEC'"PLATES&SCREWS AROUND PENETRATION 2. IF PLATES AND FASTENERS ENCROACH INTO THE SEAM AREA OF THE POCKET, THEN A TARGET MUST BE ADDED FIRST TO COVER FASTENERS. 3.25 YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES 4.APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD® DETAIL 115). U DRAWING# THIS DETAIL APPLIES TO: erGuart'f 524 SPLIT PIPE BOOT DETAIL ALL SYSTEMS ROOF PENETRATION SERIES www.gaf.Com SCALE REVISION DATE I Camp.sod.. TPO ONLY Parsippany,NJ 07054 N.T.S. 6-22-16 REFER TO PARAPET AND WALL DETAIL FOR TERMINATION HEAT-WELDED LAP REINFORCED EVERGUARD® MEMBRANE(PERIMETER SHEET IF REQUIRED) EVERGUARD® PREFORMED CORNER HEAT-WELDED LAP 0 ........................ ..................................... ............................................ ........................................ ............................................. STEP 1 .......................................... ............................................ ............................................ ........................................... ........................................... ........................................... .............................................................................................. ........................................................................................... ....................................................................................... STEP 2 NOTE: 1. FOR INSULATION THICKNESS GREATER THAN 8"(203 mm), A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY. :. 2. IF EVERGUARD®FREEDOMTM MEMBRANE IS USED, BONDING ADHESIVE IS :'? ''' ....... :. ..: i........ :.... NOT NEEDED AND WALL MUST BE PRIMED. ":'i?t:A.. ::s":::: ......:::'' 3. FLASHINGS MAY BE ADHERED OR INSTALLED DRY. SEE SPEC FOR DIRECTIONS. 4. KEEP FASTENERS BACK FROM CORNER 6"(152 mm)MAX. IN BOTH HORIZONTAL ........... AND VERTICAL APPLICATIONS. ALTERNATE 5. APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO WALL/CURB ATTACHMENT EDGES (REFER TO EVERGUARD®DETAIL 115). DRAWING t THIS DETAIL APPLIES TO: uar+d OUTSIDE CORNER REINFORCEMENT PARAPET WALL& 329A _ PREFORMED CORNER DETAIL ALL SYSTEMS CURB SERIES W W W.gaf.com SCALE REVISION DATE I Campus Od— P—ippaoy.NJ 07054 N.T.S. 6-20-16 REINFORCED EVERGUARD® MEMBRANE (PERIMETER SHEET IF REQUIRED) HEAT-WELDED LAP EVERGUARD® PREFORMED UNIVERSAL CORNER- HEAT-WELDED .... ......... ........................................ . ..:...... CORNER-WELD OR HEAT-WELD MEMBRANE PIECE TO MEMBRANE FLASHING HEAT-WELDED LAP EC7 PLATES&ILL ........ .. .. ..:: . """ "' "' [152mm]O.C. FOR BALLASTED ' SYSTEMS) ENERGYGUARDMROOF INSULATION ROOF DECK/SUBSTRATE NOTE: 1. FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY 2. IF EVERGUARD® FREEDOM" MEMBRANE IS USED, BONDING ADHESIVE IS NOT NEEDED AND WALL MUST BE PRIMED. 3. 25 YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES 4. FLASHINGS MAY BE ADHERED OR INSTALLED DRY. SEE MANUAL FOR DIMENSIONS. 5. INSIDE CORNERS MAY ALSO BE FIELD-FABRICATED USING UNREINFORCED MEMBRANE. 6.APPLY EVERGUARD® TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). ® DRAWING# THIS DETAIL APPLIES TO: Zv-erGua!A INSIDE CORNER REINFORCMENT- ' PARAPET WALL& 327A PREFORMED CORNER DETAIL ALL SYSTEMS CURB SERIES www.gaf.com SCALE REVISION DATE 1 Campus Drive. Parsippany,NI 01 N.T.S. 6-20-16 20-YEAR MAX EVERGUARD® TPO COVER TAPE GUARANTEE METAL DRIP EDGE WITH TPO ONLY HEMMED EDGE EVERGUARD® TPO PRIMER CONTINUOUS BEAD OF FLEXSEACCAULK GRADE SEALANT OR EVERGUARD®CUT EDGE SEALANT(SEE NOTE 4) GALV.ANGULAR SHANK ROOFING NAILS 4" (102 mm)O.C. STAGGERED OR DRILL—TEC SCREWS 12"(305 mm)O.C. SHEET METAL GUTTER BY OTHERS ANGULAR ROOFING NAILS 12"(305 mm)O.C. REINFORCED EVERGUARD® MEMBRANE (PERIMETER SHEET IF REQUIRED) ROOF DECK/SUBSTRATE ENERGYGUARD�4 ROOF INSULATION WOOD NAILER, 5/4"(31.8 mm)x 4" (102 mm)MIN SECURED TO SUBSTRATE NOTE: 1. FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY. 2. CLEAN METAL AND MEMBRANE WITH EVERGUARD®TPO SEAM CLEANER AND ALLOW TO DRY. ONCE DRY, PRIME METAL AND MEMBRANE WITH EVERGUARD®TPO PRIMER BEFORE INSTALLING EVERGUARD®TPO COVER TAPE. 3.THIS DETAIL IS NOT TO BE USED ON SLOPES GREATER THAN 1:12. FOR SLOPES GREATER THAN 1:12, REFER TO EVERGUARD DETAIL 218 OR 219 . 4. FLEXSEACCAULK GRADE SEALANT SHOULD BE FEATHERED OUT AND APPLIED TO BOTH INSIDE AND OUTSIDE EDGES. ENSURE PRIMER EXTENDS UNDER FLEXSEACCAULK GRADE SEALANT. 5. APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD® DETAIL 115). ® DRAWING# THIS DETAIL APPLIES TO: uarc� 2 4B COVER TAPE AT GUTTER EDGE Adhered Systems Mechanically Attached ROOF EDGE SERIES DETAIL Systems Self-Adhered Systems w .gafxom SCALE REVISION DATE Camps Dn"a 10-3-17 Parsippany.NJ OIOSA N.T.S. REINFORCED EVERGUARD®MEMBRANE UNREINFORCED PREFABRICATED EVERGUAREPT-JOINT COVER PATCH OR FIELD-FABRICATED UNREINFORCED T-JOINT PATCH 4"(102 mm)MIN. IN DIAMETER EVERGUARDP TPO CUT EDGE SEALANT FOR EVERGUARD® FREEDOM" :::;::: y:::: ;' : TPO MEMBRANE, MEMBRANE ::i`::.::•:::.:: :.::::::::: SURFACE MUST BE PRIMED WITH . .............. ....... . . EVERGUARD®TPO PRIMER(SEE ............................... ............. :.::::........................:::::: ::: :: ::::::?: :::: " .. :::::: ::::: ::::::::::..... NOTE#3) ....................................... .... .......... ...................... .......... ...............................:......... ...... ................... ........................... ............................................. ............ ........... ... ...................... ......................... ... ............. ......... ...... ...................... ........................ :::::::::. ............. ............ ........ ....... ....................... ...................... ................. ................................................ .:::::: : :: ........................... ......................................... :::::. .............. ................................................... ....:: :. .: :. .....i°...............:_.. ::::. :: ::....:•::::::.' `:::::;:: :.:::::::::::::::::::::::::::::::::::::::::::::: :: :::::::.. ...................... ........................................................... ................................................. .......... ... ................................................... .............................................. .. ........... . ................................................. .............::::. ::......... ................ ........... ................................................ . ............................................ .............. . ............................................... . ............................................. ............. ............................................... .... ........................ .......... .................................... ... ................ APPLY SECOND T-JOINT COVER PATCH OVER ADJACENT HEAT-WELDED LAP ... ....................... .... ............. TRIM EDGE OF OVERLYING NOTE: SHEET FOR EASY INSTALL OF T-JOINT(NOT REQUIRED) 1. FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A HARD BOARD IS REQUIRED ON MECHANICAL SYSTEMS ONLY. 2.T-JOINT IS TO BE USED FOR 60, 70&80 MIL TPO AND 80 MIL PVC ONLY. 3. APPLY EVERGUARD®TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES (REFER TO EVERGUARD®DETAIL 115). 8 w DRAWING# THIS DETAIL APPLIES TO: uC� Adhered Systems 105A T-JOINT COVER PATCH DETAIL RhinoBondSyst ms FIELD OF ROOF Mechanically Attached Systems SERIES TriPosite Systems www.gaf.com SCALE REVISION DATE FOR 60 THRU 80 MIL TPO AND 80 MIL PVC MEMBRANES ONLY PaCampus DA—rsippany.NJ 07054 N.T.S. 6-6-16 ARCHITECTURAL • DETAIL DRAWINGS EverGuard'TPO/PVC Architectural Roofing Details Manual REFERENCE EVERGUARD®300 SERIES PARAPET WALL&CURB FLASHING DETAILS FOR WALL TERMINATION TYPICAL EVERGUARD®PERIMETER HALF SHEETS �0 0 FT 0 0 0 0 0 6—b 0 0 0 0 0 o 6-6 0(5-6 0 0 0 0 0 0 0 01 1° 1° L °1 10 0 0 0 0 0 ° 0 0 0 O O O O O ° 0 0 ° O Quo °I ' 0 ° 0 I ° 0 01 1004 00° 000°o000000000o0 0_;0 ° 10 1 1 °I °I 01 1° 10 10 1 ° I° 01 01 °I 10 10 10 l0 l0 01 01 01 0 ° °10 10 10 10 I I 1 01 0 0 0 10 10 0 0 0 l0 I° I° 01 01 01 10 10 10_ _ _ _ _° 1° - - - 01 01 01 10 10 10 I° 01 01 °I 10 1° 1° 10 10 °I °I 01 1° 10 10 10 10 01 01 °I nEl l0 l0 l0 I° I° 01 01 01JE 10 10 10 10 - - - �0 01 °I °I 10 10 10 1°0 10 01 01 01 ALTERNATE 1 0 10 1 I I 1 01 o I° 1° o 0 0 0 10 10 10 0 0 01 01 01 10 10 10 10 10 01 01 01 1° 10 10 10 10 01 01 01 0 c� 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0\0 0 R%�o�0 01 0 0 0 0 0 ° o (5-o0 0 0 0 0 0 0 0 0 0 0 0 q__0_ 0 0 0 _0 1 to �0 0 0 0) 01 L — - - - J ° EVERGUARD®MEMBRANE HEAT-WELDED SEAMS DRILL-TEC. PLATES&SCREWS REFERENCE EVERGUARD®200 SERIES ROOF EDGE FLASHING DETAILS FOR EDGE NOTE: TERMINATION 1.SEE EVERGUARD®MECHANICALLY ATTACHED SYSTEM GUIDELINES TO DETERMINE FASTENER SPACING FOR VARIOUS DECK TYPES AND WIND UPLIFT REQUIREMENTS,AND FOR REQUIRED NUMBER OF PERIMETER HALF SHEETS. 2.FOR INSULATION THICKNESS GREATER THAN 8"(203 mm),A COVER BOARD IS REQUIRED ON MECHANICALLY ATTACHED SYSTEMS ONLY. DRAWING N THIS DETAIL APPLIES TO: )EV�UaIa Mechanically ' FIELD OF ROOF 101A ROOF MEMBRANE LAYOUT DETAIL Attached Systems SERIES www.gat.com SCALE REVISION DATE PaNppany m-y D.NJ 01054 N.T.S. 6-15-17 23 12" • • 36" • 36" 12" 6" 18" 18" 6" ® DRAWING# SYSTEM FASTENING 5 FASTENERS PER 4' x 8' BOARD 5 INFP-8' PATTERNS viww.gaf.com SCALE ISSUE/REVISION DATE I Campus Drive. INSULATION BOARD SPECIFY CORNER-PERIMETER-FIELD Parsippany,NJ N.T.S. 7-13-15 07054 Product Data Sheet EverGuard® Sealants Description GAF EverGuard®single-ply roofing systems include a full line of EverGuard/GAF sealants. Note:EverGuard®/GAF sealants are specially formulated for specific applications:be sure to use the correct sealant for the application.The following EverGuard®/GAF sealants area available: Units Carton Product Description Benefit/Application Per Carton Weight 1verGuard® One-part butyl-basad •Suitable for sealing between flashing 25 13 lbs. Water Block high-viscosity sealant membrane and substrate surface behind 10.5 oz.cartridges exposed termination bars •Suitable for sealing between roofing membrane and drain flanges EverGuard® 100`&solids •Suitable for filling sealant pans at irregularly- 1 kit=1 gal Part A and 18 lbs. 2-Part Pourable urethane-based shaped penetrations I pint Part B two-part sealant 2 kits per carton Sealant EverGuard® Sealant used at any •Used to seal non-factory edges(cut edges)as a •12 pints/cm. 12 lbs. TPO&PVC non-factory edge final step in reinforced membrane installation •100 lineal feet per pint Cut Edge of TPO and PVC •PVC Cut Edge with PVC @ 1/8"diameter bead. membrane •TPO Cut Edge withTPO Sealant Storage:•Store sealants in original containers on pallets or shelving in a dry area. •Store sealants in 50-100•F conditioned area away from open flame or other combustion source. •Do not allow to freeze. 49 Product Data Sheet 30 A f4y4kKquardPreformed OOF/NG SYSTEMS Accessories Description EverGuard°TPO single-ply roofing system preformed accessories • �_ provide roofing contractors an easy-to-install, factory-built detail. • EverGuard°preformed accessories are constructed from GAF's proven, ��` (� durable EverGuard*TPO single-ply reinforced membrane. • Cost effective... Reduces installed costs U • Improved reliability... Factory-built accessories reduce Urisk of leaks and callbacks • Improved aesthetics... Uniform look Application Split Pipe Boot EverGuard*TPO preformed accessories are designed for use • Available in 3 standard sizes with GAF EverGuard* TPO single • Custom sizes also available* ply membranes. The preformed accessories may be installed SPECIFICATIONS ITEM DIMENSIONS/SKU # on mechanically attached, fully adhered, or self-adhered For pipe sizes: 1" x 2" 85G 1920 O EverGuard*TPO roofing systems. 3" x 5" 85G2920 Preformed accessories are installed using conventional techniques. b" x 8" SSG3920 01^tom See published application and SHIPPING SPECIFICATIONS specifications manual for detailed Boots per box: 6 instructions. Weight per box: Product Information 1"- 2" 7.5 lbs. EverGuard*Split Pipe Boots 3"-5" 7.5 lbs. are constructed from EverGuard* 6"- 8" 11 lbs. reinforced 45 mil membrane. Three Boxes per pallet: standard sizes of Split Pipe Boots are available. Since they are 1"-2" 36 split,they can be wrapped around 3"-5" 36 pipes and conduit where closed 6"- 8" 24 boots cannot be used. *Contact your local representative for details. Also Available... r . �, gCorner Inside Comer Preformed Vent Boot Universal Corner Vent 4 g 02014 GAF•414•a468 COMEG166 f ® DRILL=TECTM STEEL AND PLASTIC PLATES GAF MATERIALS CORPORATION Description Product , ta Pressure Drill-Tec'"Steel Plates are made of ���■■ P I at—,- Galvalume®coated steel. The round � {ii7�TJii!?�� design provides an even distribution 2'Barbed 8676 2" 1000 29 lbs Drill-Tec'" of loads and eliminates sharp corners Plate Steel Plates that can damage the insulation or 2•Double- 46DB 2 1/8" 1000 34 lbs membrane. Drill-Tec 23/8"and 23/4" Barbed Plate plates should be used for lap seam fastening. Drill-Tec"3" plates should 2 3/8'XHD 8678 2 3/8" 1000 45 lbs be used when fastening insulation. Barbed These plates are designed to be used Seam Plate with Drill-Tec'"fasteners. 2 3/4"Super 8679 2 3/4" 500 37 lbs Code Approvals XHD Plate 3'Galvalume' 4577 2 7/8" 1000 37 lbs F M MIAr® Plate 3'Lite-Deck 457B 3" 500 19 lbs APPROVED Plate / 3'Base 45JJ 3" 1000 46 lbs Sheet Plate Physical Data 2"Barbed Plate Application: Attaches EverGuard'membrane to the substrate. Fastener: Drill-Tec"HD#14 Fasteners, XHD#15 Fasteners and Drill-Tec"CD-10 Fasteners 2" Double-Barbed Plate Application: Attaches EverGuard'membrane to the substrate. s. 23/8"XHD Barbed Seam Plate Application: Attaches EverGuard®membrane to the substrate. Fastener: Drill-Tec"XHD#15 Fasteners and Drill-Tec"CD-10 Fasteners. ' 23/4"Super XHD Double-Barbed Seam Plate Application: Attaches EverGuard'membrane to the substrate. ' Fastener: Drill-Tec'"SXHD#21 Fasteners and Drill-Tec"'CD-10 Fasteners. ' 3"Galvalume®Plate Application: Attaches insulation to the substrate. Fastener: Drill-Tec"Standard,#12 Fasteners, HD#14 Fasteners, - CD-10 Fasteners, Fluted Nail. Lite-Deck a e ilk Application: Attaches insulation to gypsum,Tectum'and lightweight concrete decks. Fastener: Drill-Tec"Lite-Deck Fastener. Base Sheet Plate Application: Attaches base sheets to lightweight insulating concrete and various gypsums. Fastener: Drill-Tec'"Standard or 1.2 Base Sheet Fastener. Drill-Tec'" Description Product Data Plastic Plates Drill-Tec"3"plates should be used when fastening insulation. All Drill-Tec'"plates �� are round and designed to be used with T Plastic 4578 3 1/16' 1000 25 lbs Drill-Tec"fasteners. Plate • Code Approvals 3'Locking 45J 3 1/16" 1000 25 lbs F M Mw,wwEcwrm Plastic Plate APPROVED Physical Data 3"Polypropylene Plastic Plate ri Application: Attaches insulation to the substrate. Fastener: Drill-Tec Standard, Heavy Duty, CD-10, Fluted Nail or Toggle Bolt fastener. 3"Polypropylene Locking Plastic Plate Application: Attaches insulation to the substrate. Fastener: Drill-Tec Standard, Heavy Duty or Toggle Bolt fastener. ©2009 GAF Materials Corporation 0 1/10 74 www.gaf.com • 1-800-ROOF-411 ® DRILL=TECTM ` XHD FASTENER (# 1 5) Description Coating Requirement Drill-Tec'"XHD(Extra Heavy Duty) The fastener will be coated with the Fastener(#15)is a specialized, Drill-Tec'"CR-10 corrosion resistant high-performance fastener designed coating.When subjected to 30 to secure insulation and single-ply Kesternich cycles(DIN 50018),the membrane to steel, O.S.B., or fastener must show less than 15% aluminum roof decks. red rust and surpass Factory Mutual Application Approval Standard 4470. The Drill-Tec'"XHD Fastener(#15) should always.be tested on site by a Darib GAF representative to determine per- • duct formance and proper installation proce- dure. Call GAF to schedule testing. Head Diameter .435"(11.04 mm) Note: Make sure not to overdrive the fastener. Fastener must be tight enough Thread Diameter .275'(6.99 mm) so that the plate doesn't turn. Factory Mutual requires that the fastener pen- Head Style #3 Phillips Truss Head etrates the steel deck at the top flute. Advantages Coating CR-10 •Oversized heavy shank and thread diameters for enhanced pull-out resistance in steel and aluminum roof decks. •Deep buttress threads further increase pull-out resistance. (51 mm) Fun BtTOet (9 21 lb -Miniature drill point penetrates decks quickly and contributes to (7s mm) Full Buc�kOet (13°si kg) exceptional resistance to backout as well as pullout. 4• 3" 1,000 39 lb Plates&Accessories (102 mm) (76 mm) Bucket (17.69 kg) A variety of plates are available. Contact 127 mm) (102 mm) Bucket (1 25 a k GAF to determine the appropriate plate ( g) for your application. 6' 4' 500 29 Ib (152 mm) (102 mm) Bucket (13.15 kg) Specifications 7' 4" 500 33 lb The fastener will be a Drill-Tec"'XHD (178 mm) (102 mm) Bucket (14.97 kg) Fastener(#15)with a thread diameter 8' 4" 500 38 Ib of.275"(6.99 mm).The fastener must (203 mm) (102 mm) Bucket (17.24 kg) Drill-Tec"XHD have 13 threads per inch(per 25.4 9' 4" 500 41 Ib Fastener(#15) mm)and a drill point.Also,the fastener (229 mm) (102 mm) Box (18.60 kg) must be heat-treated per specification 10' 4' 500 46 lb OMG-1.The Drill-Tec"XHD Fastener (254 mm) (102 mm) Box (20.87 kg) (#15)will be used with a Factory Mutual- 11' 4' 500 52 Ib approved, Drill-Tec'"Round Pressure (279 mm) (102 mm) Box (23.59 kg) Plate or Pressure Bar. 12' 4" 500 55 Ib (305 mm) (102 mm) Box (24.95 kg) Code Approvals 14' 4" 250 33 lb (357 mm) (102 mm) Box (14.97 kg) 16' 4" 250 38 lb O caNrr (406 mm) (102 mm) Box (17.24 kg) ApplOM 18' 4" 250 42 lb (457 mm) (102 mm) Box (19.05 kg) 20' 4" 250 45 lb (508 mm) (102 mm) Box (20.41 kg) 22' 4' 125 501b (559 mm) (102 mm) Box (22.68 kg) Note:All sizes are nominal. 02017 GAF 7117 gaf.com • 1-800-ROOF-411 Flat Stock Physical Characteristics and Shipping Information Physical Characteristics Shipping Information (4' x 4') Shipping Information (4' x 8') (1.21 mx1.21 m) (1.21 mx2.44m) Size' R-Value Max Flute Bds/ Bds/Truck Bundles/ Sq.Ft.Per Bds/ Bds/Truck Bundles/ Sq.Ft.Per Span(in) Bundle Truck Truck Bundle Truck Truck 1.0"(25.4 mm) 5.6 2 5/8"(66.7 mm) 48 2,304 48 36,864(3,425 sq.m) 48 1,152 24 36,864(3,425 sq.m) 1.1"(27.9 mm) 6.2 2 5/8"(66.7 mm) 43 2,064 48 33,024(3,068 sq.m) 43 1,032 24 33,024(3,068 sq.m) 1.2"(30.5 mm) 6.7 2 5/8"(66.7 mm) 38 1,824 48 29,184(2,711 sq.m) 38 912 24 29,184(2,711 sq.m) 1.3"(33 mm) 7.3 3 5/8"(92 mm) 36 1,728 48 27,648(2,568 sq.m) 36 864 24 27,648(2,568 sq.m) 1.4"(35.6 mm) 17.9 4 3/8"(111 mm) 34 1,632 48 26,112(2,426 sq.m) 34 816 24 26,112(2,426 sq.m) 1.5"(38.1 mm) 8.6 4 3/8"(111 mm) 32 1,536 48 24,576(2,283 sq.m) 32 768 24 24,576(2,283 sq.m) 1.6"(40.6 mm) 9.1 4 3/8"0 11 mm) 30 1,440 48 23,040(2,140 sq.m) 30 720 24 23,040(2,140 sq.m) 1.7"(43.1 mm) 9.6 4 3/8"(111 mm) 28 1,344 48 21,504(1,998 sq.m) 28 672 24 21,504(1,998 sq.m) 1.8"(45.7 mm) 10.2 4 3/8"(111 mm) 25 1,200 48 19,200(1,784 sq.m) 25 600 24 19,200(1,784 sq.m) 1.9"(48.3 mm) 10.8 4 3/8"(111 mm) 25 1,200 48 19,200(1,784 sq.m) 25 600 24 19,200(1,784 sq.m) 2.0"(51 mm) 11.4 4 3/8"(111 mm) 24 1,152 48 18,432(1,712 sq.m) 24 576 24 18,432(1,712 sq.m) 2.1"(53 mm) 12.0 4 3/8"(111 mm) 22 1,056 48 16,896(1,570 sq,m) 22 1528 24 16,896(1,570 sq.m) 2.2"(56 mm) 12.6 4 3/8"(1 1 1 mm) 21 1,008 48 16,128(1,498 sq.m) 21 1504 24 16,128(1,498 sq.m) 2.3"(58 mm) 13.2 4 3/8"(1 1 1 mm) 20 960 48 15,360(1,427 sq.m) 20 480 24 15,360(1,427 s .m) 2.4"(61 mm) 13.8 4 3/8"(111 mm) 20 1960 48 15,360(1,427 sq.m) 20 480 24 15,360(1,427 sq.m) 2.5"(64 mm) 14.4 4 3/8"(111 mm) 19 912 48 14,592(1,356 sq.m) 19 456 24 14,592(1,356 sq.m) 2.6"(66 mm) 15.0 4 3/8"(111 mm) 18 864 48 13,824(1,284 sq.m) 18 432 24 13,824(1,284 sq.m) 2.7"(69 mm) 15.6 4 3/8"(111 mm) 17 816 48 13,056(1,213 sq.m) 17 408 24 13,056(1,213 sq.m) 2.8"(71 mm) 16.2 4 3/8"(111 mm) 17 816 48 13,056(1,213 sq.m) 17 408 24 13,056(1,213 sq.m) 2.9"(74 mm) 16.8 4 3/8"(111 mm) 16 768 48 12,288(1,142 sq.m) 16 384 24 12,288(1,142 sq.m) 3.0"(76 mm) 17.4 4 3/8"(111 mm) 16 768 48 12,288(1,142 sq.m) 16 1384 24 12,288(1,142 sq.m) 3.1"(79 mm) 18.0 4 3/8"(1 1 1 mm) 15 720 48 11,520(1,070 sq.m) 15 360 24 11,520(1,070 sq.m) 3.2"(81 mm) 18.6 4 3/8"(111 mm) 15 1720 48 11,520(1,070 sq.m) 15 360 124 11,520(1,070 sq.m) 3.25"(83 mm) 18.9 4 3/8"(1 1 1 mm) 14 672 48 10,752(999 sq.m) 14 336 24 10,752(999 sq.m) 3.3"(84 mm) 19.2 4 3/8"(1 1 1 mm) 14 672 48 10,752(999 sq.mJ 14 336 24 10,752(999 sq.m) 3.4"(86 mm) 19.9 4 3/8"(1 1 1 mm) 14 672 48 10,752(999 sq.m) 14 336 24 10,752(999 sq.m) 3.5"(89 mm) 20.5 4 3/8"(1 1 1 mm) 13 624 48 9,984(928 sq.m) 13 312 24 9,984(928 sq.m) 3.6"(91 mm) 21.1 4 3/8"(1 1 1 mm) 13 624 48 9,984(928 sq.m) 13 1312 24 9,984(928 sq.m) 3.7"(94 mm) 21.7 4 3/8"(1 1 1 mm) 12 576 48 9,216(856 sq.m) 12 288 24 9,216(856 sq,m) 3.8"(97 mm) 22.3 4 3/8"(1 1 1 mm) 12 576 48 9,216(856 sq.m) 12 288 24 9,216(856 sq.m) 3.9"(99 mm) 123.0 4 3/8"0 11 mm) 112 576 48 9,216(856 sq.m) 12 288 124 9,216(856 sq.m) 4.0"(102 mm) 123.6 4 3/8"(111 mm) 112 576 48 9,216(856 sq.m) 12 288 124 9,216(856 sq.m) *Other sizes available upon request Tapered Physical Characteristics and Shipping Information Physical Characteristics Shipping Information (4' x 4') (1.21 m x 1.21 m) Slope Thickness Size' Bds/ Bds/ Bundles/ Sq.Ft.Per Bundle Truck Truck Truck 1/8"(3.18 mm) .5"-1"(12.7 mm-25.4 mm) AA 64 3,072 48 49,152(4,566 sq.m) 1"-1.5"(25.4 mm-38.1 mm) A 38 1,824 48 29,184(2,711 sq.m) 1.5"-2"(38.1 mm-51 mm) B 26 1,248 48 19,968(1,855 sq.m) 2"-2.5"(51 mm-64 mm) C 20 960 48 15,360(1,427 sq.m) 2.5"-3"(64 mm 76 mm) D 116 768 48 12,288(1,142 sq.m) 3"-3.5"(76 mm 89 mm) E 14 672 48 110,752(999 sq.m) 3.5"-4"(89 mm 102 mm) F 12 576 48 9,216(856 sq.m) 1/4"(6.35 mm) .5"-1.5"(12.7 mm-38.1 mm) X 48 2,304 48 36,864(3,425 sq. m) 1.5"-2.5"(38.1 mm-64 mm) Y 24 1,152 48 18,432(1,712 sq. m) 2.5"-3.5"(64 mm-89 mm) Z 16 768 48 12,288(1,142 sq.m) 1"-2"(25.4 mm-51 mm) G 32 1,536 48 24,576(2,283 sq.m) \, 2"-3"(51 mm-76 mm) H 19 912 148 14,592(1,356 sq.m) ,3"-4'(76 mm- 102 mm 1 12 �576 t48 t24,576 856 s .m1/2"02.7 mm) .5"-2.5"(12.7 mm-64 mm) Q 32 536 (2,283 s .m) 1"-3"(25.4 mm-76 mm) XX 22 056 6(1,570 sq.m) t er sizes available upon request 02014 GAF 9/14"#384 COMGT318 neErWG, TM a Quality You Can Tapered crickets as needed PO LYI SO I N S U LATI O N Trust...From North America's Largest Roofing Manufacturer!`" ,� ,.-_ " +sem Description • Manufactured with EPA-compliant blowing EnergyGuard" Polyiso Insulation board agents containing no CFCs or HCFCs; is made of glass fiber-reinforced cellulosic has zero ozone depletion potential (ODP) felt facers bonded to a core of isocyanurate and virtually no global warming potential foam. EnergyGuord" Polyiso Insulation (GWP) manufactured in our plants use the latest • Available in a variety of thicknesses from technology in manufacturing to provide 0.5" (12.7 mm) to 4.0" (102 mm) to best a product of the highest quality. suit your needs Features and Benefits • Available in 4' x 4' (1.21 m x 1.21 m) Enerand 4' x 8 (1.21 m x 2.44 m) boards • designed u Polyiso Insulation is . Tapered panels are also available for desi ned for use in practical) any P low- roof application, including when the roof design requires improved built-uproofs modified bitumen, or drainage in slopes of 1/16" (1.59 mm),") most i gle-ply roofing systems 3/16" (4.76 mm), 1/8" (3.18 mm), 3/8" (9.53 mm), 1/4" (6.35 mm), • High insulation value — Superior "LTTR° and 1/2" (12.7 mm) value compared to any other FM Class I rated product of equivalent EnergyGuard"Polyiso Insulation thickness at 5.7 per inch and Tapered Polyiso Insulation • Meets the requirements of ASTM C1289 Codes & Compliance Type II, Class 1, Grade 2 (20 PSI), and . FMA p specs assemblies roved—consult RoofNay.com for available in Grade 3 (25 PSI) i N i • Because of its light weight, this material . UL Classified—consult ul.com forspecific is easy to handle on the job site and installs faster. Easier cutting in the field assemblies 0 provides the installer with simplified • For additional information contact GAF Fabricating on the roof deck Technical Services at 1-800-ROOF-411 _ 0 or technicalquestions@gaf.com ^L' W TYPICAL PHYSICAL PROPERTY DATA CHART(POLYISO FOAM CORE ONLY) PROPERTY TEST METHOD VALUE Compressive Strength ASTM D 1621 >_20 PSI Z3 Dimensional Stability(Length+Width) ASTM D2126 < 2% U Water Absorption ASTM C209 < 1.5% Moisture Vapor Transmission ASTM E96 < 1.5 Perm C/) Service Temperature -100°to 250°F(37.81 to 121.1'Cl L� Flame Spread Index ASTM E84 < 75* Smoke Developed Index ASTM E84 < 200* gat com *Foam Core ° ENERGYGUARUm HD & HD PLUS POLYISO INSULATION Description •Meets FM Approval criteria for severe hail EnergyGuardTm HD Polyiso Insulation(HD) damage resistance(Class 1-SH)when FM and EnergyGuardlm HD PLUS Polyiso Insulation Approved as a component of a Class 1-SH (HD PLUS)are 1/2'(12.7 mm)thick high-density rated roofing assembly.Refer to RoofNav® polyiso cov&boards.HD and HD PLUS con- (https://roofnay.fmglobal.com/)for specific sist of coated glass-fiber mat facers bonded to assembly approvals. high-density closed cell polyisocyanurate •FM Approvals specification tested per foam cores. FM 4473 for Class 3 impact resistance as Advantages a component of a Class 3 rated roofing HD and HD PLUS have an R-Value of 2.5,the assembly.Refer to the FM Approval highest of any cover board—and,at 11 Ib.and Guide(http:/Avww.approvalguide.com/)for 13 Ib.(4.99 kg and 5.90 kg),respectively,per Specification Tested roofing assemblies. 4'x 8'(1.2 m x 2.44 m)board,they're a fraction WARNING:DO NOT EXPOSE TO OPEN of the weight of gypsum cover boards. FLAME OR EXCESSIVE HEAT.MAY SMOLDER •With over 80 psi Compressive strength for HD and IF IGNITED. IF IGNITED,EXTINGUISH 110 psi for HD PLUS and a durable coated glass COMPLETELY. facer,HD and HD PLUS are ideal boards for protecting your roof against the elements. •Manufactured with EPA-compliant blowing agents. e Compliance Contains no CFCs or HCHSs;has zero ODP. • •Excellent dimensional stability. ` •Low water permeability—lower overall perm F M rating than many conventional insulation APP110® boards. sant of Florida Approved •High moisture resistance and no capillarity; is stable and maintains its physical and insulating characteristics. Uses HD Physical Properties* When property installed,it is suitable for use pronenr vako Test NMhod under built-up,modified bitumen,and most single-ply roofing systems. Compressive strength Min.80 psi. ASTM D1621 Refer to the application specifications in the Dimensional Stability Less than 0.5%linear ASTM D2126 (7 days at 158OF[70'Cl change current membrane manufacturer's application 97%FIR) and specifications manual or proper membrane installation procedures. water Absorption Less than 1.5%by ASTM C209 •4'x 4T.21 m x 1.21 m)1/2'(12.7 mm)thick 12hrsunder 1' volume HD or HD PLUS may be hot asphalt-adhered 125 4 mml water) to substrates. Resistance to Mold Passed(10) ASTM D3273 •Fleece-back TPO may be hot asphalt-adhered Service Temperature 2W°F(126.7°C)or less to 1/2'(12.7 mm)HD or HD PLUS. Recycled Content Max.8% Limitations and Potential Fire Hazard Tensile Strength Min.5000 psf ASTM 0209 •HD and HD PLUS are non-structural,non EnergyGuard"HD load-bearing materials.They are not designed 'Foam core only. and HD PLUS Polyiso for direct traffic usage unless adequately Insulation protected. •Direct torching of modified bitumen mem- branes to HD and HD PLUS is not approved. HD PLUS Physical Properties' •Direct mopping of modified bitumen and v Teat a built-up roofing(BUR)to HD and HD PLUS is propwity y not approved. Compressive Strength Min.110 psi. ASTM D1621 • HD and HD PLUS Polyiso Insulation should be Dimensional Stability Less than 0.5%linear ASTM D2126 + + stored dry and protected from the elements. (7 days at 158°F[70°Cl change Bundle wrap is not for use as waterproofing for 97%RH) boards.No more insulation should be installed Water Absorption Less than 1.5%by ASTM 0209 than can be completely covered with roofing (2 hrs.under 1' volume + + on the same day. [25.4 mm]water) •As unprotected polyisocyanurate will burn, Resistance to Mold Passed(10) ASTM 03273 + fire safety precautions should be observed Service Temperature 260°F(126.7°C)orless wherever insulation products are used. Recycled Content Max.8% Code Compliance •Meets ASTM C 1289 Type 2,Class 4,Grade 1 Tensile Strength Min.5000 psf ASTM C209 (80 psi)and Grade 2(110 psi). 'Foam core only. •Meets FM 4450/4470 and UL 790. ©2017 GAF 7/17 gaf.com • 1-800-ROOF-411 EverGuardO TPO 60 mil Membrane Applicable Standards UL Listed, FM Approved, Miami-Dade County Approved, Florida Building Code Approved, CRRC Listed, Title 24 Compliant', ENERGY STAR®Qualified",ASTM D6878. Physical Properties ASTM Test Method ASTM D6878 Minimum EverGuard" Typical Test Data 1.Certain data is provided in MD(machine direction)x CMD(cross machine direction)format. 2.Data is based upon typical product performance,and is subject to normal manufacturing tolerance and variance. Nomrnal Thickness ASTM D751 0.039'(min.)(0.99 mm) 0.060"(1.52 mm) Breaking Strength ASTM D751 Grab Method 220 Ibf/in.(38.5 kn/ml 305 Ibf x 290 Ibf(454 x 432 kg/m) Factory Seam Strength ASTM D751 66 Ibf(98.34 kg/m) 135 Ibf(membrane failure)(201.1 kg/m) Elongation at Break ASTM D751 15% 30% Heat Aging ASTM D573 90%Retention of Breaking Strength 100% and Elongation at Break Tear Strength ASTM D751 8'x 8'(203 x 203 mm)Sample 55 Ibf(81.95 kg/m) 75 Ibf x 130 Ibf(1 1 1.8 x 193.7 kg/ml Puncture Resistance FTM 101 C Method 2031 Not Established 380 lbs.(172 kg) Cold Brittleness ASTM D2137 -40'C -40'C Permeance ASTM E96 Not Established 0.08 Perms Dimensional Change ASTM D1204 @158 F(70°C),6 hrs. 41% 0.4% Water Absorption ASTM D471 ®158°F(70°C), 1 week +/-3.0%(top coating only) 0.7% Hydrostatic Resistance ASTM D751 Method D Not Established 430 psi Ozone Resistance ASTM D1 149 No visible deterioration 0 7 x No visible deterioration @ 7 x magnification magnification Reflectivity(white)Initial/Aged ASTM C 1549 N/A 0.76/0.68 Emissivity(white)Initial/Aged ASTM C 1371 N/A 0.90/0.83 Weather Resistance ASTM G 155/D6878 10,080 KJ/(m2•nml at 340 nm >25,000 K1/(m' nml at 340 nm Heat Aging ASTM D573 240T(1 15-Cl for 32 weeks 60 weeks Thickness Above Scrim JASTM D7635 I Min 30%of Total Thickness 22.1"1561 mml(Nominal) Guarantee Up to 25 years *White, Energy Gray, and Energy Tan Membranes Only **ENERGY STAR®only valid in the USA Product Data Note: Product sizes,dimensions,and widths are nominal values and are subject to normal manufacturing/packaging tolerance ._.__< and variation. Colors Full Size Rail Full Roll Weight Half Rail Size Half Roll Weight 'Vhite, 10'x 100' 322 lbs. (146 kg) 5'x 100' 162 lbs. (73.5 kg) www (3.05 x 30.5 m) (1.52 x 30.5 m) 6reY— (1,000 sq.ft. (500 sq.ft. [92.9 sq.m]l [46.5 sq.m]] 8'x 257 lbs. (1 17 kg) 4'x 100' gl (2.44x 30.5 m) (800 sq.ft. [74. [37.1 sq.m]) Note: Membrane rolls shipped horizontally on pallets,stacked pyramid-style and banded. Store rolls on their sides on pallets or shelving in a dry area. Membrane rolls are heavy. Position and install by at least two people. Quality You Can Trust... From North America's Largest Roofing Manufacturer!" gaf.Com ©2014GAF 11/14•#342 ky9,kquardTM Molded OOFING SYSTEMS Accessories Description EverGuard" TPO single-ply roofing system molded accessories ' provide roofing contractors �— an easy-to-install, factory-built O detail. EverGuard molded accessories are manufactured using a proprietary formulation designed for use with GAF's EverGuard'TPO single-ply ' membranes. • Cost effective... U Reduces installed costs • Improved reliability... U Factory-built accessories reduce risk of leaks and callbacks • Improved aesthetics... Vent Boot Uniform look Application • One standard size accommodates most common EverGuard' TPO molded pipes and conduits accessories are designed for • Supplied with stainless-steel clamping rings use with GAF EverGuard®TPO W single-ply membranes and EverGuard` Freedom"TPO SPECIFICATIONS self-adhering membranes. The molded accessories may be Membrane thickness: 0.075" installed on mechanically attached, For pipe sizes: 1" - 6,, dia. O fully adhered, or self-adhered SHIPPING SPECIFICATIONS EverGuar&TPO roofing systems. EverGuard" molded accessories Boots per carton: 6 are installed using conventional Weight per carton: 9 lbs. techniques. See published application and specifications Cartons per pallet: 54 manual for detailed instructions. PRODUCT SKUs Product Information Vent Boot White 17710920CU EverGuard= Vent Boots are molded from a proprietary TPO formulation engineered to work with EverGuardO TPO single-ply membranes. Vent Boots allow for fast flashing of Vents and pipes between 1 and 6 inches in diameter. Also Available... Irma � . + . gat com Fluted Caner Inside Comer Pourable Sealer Pocket Universal Corner Vent 02014 GAF•4114•M468 COMEG160 E9lOWOO 9948.4U4•AVE)4107.0 JuGA dDAMegnlaionbS J0094uGnPauu°i9Jd JOUJOD apsul JawoaPaWll LU0O Ie6 l` I ll• ...algolioAv osly •swat! ONq/UoIuanu! 01 paau ay4 a4ou!w!la sJauJoD losjaA!uf1 ®pjonOjaA3 -4uawaajo4u!aa jaujoa ap!sano jo ap!su! uo 194419 aonpoid of s6u!ljow#o in:)Aldw!S s6u!4solJ gjno puo asoq jo sjaujoo ap!s4no puo ap!su! yaoq ampowwoaao nDo660£LL al!yM sJawoD losJaA!un op,onOjaA3 sms i:)naObd uol;DLUAOJUI 42npoad 09 :;allod jad suo#JoD suo!;awisui sql q :uo4joa gad 4y6!9M pal!oiap joj lonuow suo!4oa!l!aads q :uo4joa jad siauioD puo uo!loallddo paysllgnd aaS SNOI1d:)131:)3dS JNIddIHS •sanb!uyoaa louo!Iuanuoa 6ulsn palloasu! ajo sauossaaao paplow „090' :ss9ulo!41 ®pjongjaA3 •swals/\s 6u!Ioa Odl a6uol j pjonOJaA] paJaypo-}las ao 'paJaypo • WM„q X„q :az!S AlInf 'payoo4o lloo!uoyoaw uo O palloasu! aq ADW sauossaoao paplow SNOINDIADUS ayl •sauojgwaw 6uua4po-Jl9s Odl W,wopaei j ®pjonOJ9A] Odl woof ssaulaly; pw 09 o; paploW . puo sauojgwaw Aldal6u!s ;uawaaloiulaj jauloa ap!s;no jo Odl®P'onOJ9A3 jb'O yl!m asn apisul uo Jay;la so asn alopoww0004 o4 46 aq uoD . Joj pau6!sap ago sauossaaao ' PaPI°w Odl®PJ mjdd 3 ^ azis pJopuo;s 9u0 . uol;o�I�dd�/ aauJOD irmaAlunlool wjoj!un •••s�i;ay;sao psAoadwl . ► sjDoglloo puo sloal jo Isu aanpai sa!aossaaao 41!nq-Ajoiaoj r.r •••/4i1!goyaa poAoidwl . s#soa palloisu! saanpad •••aAi;�ajja 4so0 . •sauojgwaw AldalBu!s Odl®PjonOjaA3 s,jy0 44!m asn jo}} pau6!3ap uo!aolnwjoj Ajopidoid o Bu!sn pain4 -aojnuow ajo sauossaaoo paplow ion iotan jan ! jo4ao ®P o 3 I• P I. ) B i • II°}SUI-0�-/�SDa UD SJO�aD1�U0a U1i00J O aplAad sauossaaoo paplow walsAs 6u!jooi AldalBu!s Odl®PJDnOaaA3 uoi;di.iasea saiaossa��d SW 3lS/lS JN/�OOt/ J�7d-379N/S ' PROW Product Description Benefit/Application Quantity/Size Weight Square Tube •Square tube wraps are •Fast efficient alternative to field 6 Tube Wraps per 6-7 Wraps fabricated from 45 mil fabrication carton lbs/carton thick reinforced TPO •Tube wraps are split with a designed Three Sizes: 4"x 4" membrane overlap so they can be wrapped 4"x 6" around square or rectangular tubing 6"x 6" and ensure a solid weld •Available in three standard sizes Inside Corners •Inside Comers are •Manufactured to accommodate 20 Comers per carton 3.5 formed using inside comers of base and curb 6"x 6"x 5 1/4" lbs/carton unreinforced flashings membrane to a •Designed for ease of welding in tight nominal 50 mil areas thickness Pourable •Pourable Sealer •Provides a structural foundation for 6 Pockets per carton 6.5 Sealer Pocket Pocket is molded with application of EverGuard Pourable 9"x 6"x 4"oval with lbs/carton TPO compound to a Sealant with primer or a non- 3"base flange nominal 70 mil shrinking grout thickness •Lower cost than coated metal •White Only fabricated pockets •Ideal for waterproofing irregular shaped roof penetrations •Pocket can be split and flashed with detailing membrane for applications around continuous pipes or penetrations Drain •Spun Aluminum drain •For use in waterproofing low slope 3 Drains per carton 3.25-3.70 preflashed with 55 mil roof drains 10 sizes available:I lbs/carton unreinforced TPO •Fast efficient altemative to field 1/2"to 6"in half inch membrane fabrication increments •White Only Scupper •Manufactured out of •For use in waterproofing wall 2 Scuppers per carton 5-9 TPO Coated Metal scuppers 4"x 6"x 12" Ib'carton and 55 mil •Eliminates unnecessary flashing to 8"x 10"x 12" unreinforced waterproof the wall opening membrane •White Only Vent •Manufactured out of •For use in venting low slope 2 Vents per carton 1; reinforced 45 mil mechanically attached roofs bsicarton TPO membrane and •Limited to one-way flow to avoid galvanized steel moisture buildup within the roofing •White only structure and material 1/9/2009 Product Description Benefit/Application Quantity/Size Weight TPO Cover •30 mil TPO •For use in stripping in primed •6"x 100'roll 50 lbs/carton Tape membrane laminated galvanized edge metal •2 rolls/carton to white butyl tape •For use in 10&15 year guarantees only Preformed •Boots are fabricated *Three standard sizes are split to 6 Boots/carton Split Pipe from 45 mil thick accommodate most common pipes Stock Sizes Boots reinforced TPO and conduits V-2" 7.5 lbs/carton membranes 3"-5" 7.5 lbs/carton 6"-8" 11 lbs/carton Special order Size I 1 lbs/carton RTA •6"x 100'45 mil •To be installed on horizontal surfaces 6"x 100'rolls 34 Ibs/carion (Roof reinforced TPO Using plates and fasteners as a base 2 rolls/carton Transition membrane with attachment in fully adhered and Anchor)Strip pressure sensitive FreedomT systems adhesive •White only Corner Curb •Comers are fabricated -Four Standard sizes to flash curbs that 4 Curb Wraps/carton. N1 raps from 45 mil thick are 24",36",48"and 60"in size. Stock Sizes are: rein- -Four comers are required to flash the 13.5" 5.6 lbs/carton •forced TPO curb. 19.5" 7.4 lbs/carton membrane 25.5" 10.7lbs/carton 31.5" 12.5 lbs/carton Special order sizes: 7.5" 37.5" Preformed •60 mil thick •5 standard sizes to accommodate most Sizes are 4",6",8",10", Ranges from Expansion reinforced TPO applications 12"Bellows 50-65 lbs. Joint membrane *Two convenient styles available to 50 foot rolls Covers •White only accommodate both Roof-to-Roof and Roof-to-Wall applications. EverGuard SA •1-1/2"wide x 1-1/4" *Applied over TPO roofing systems to 10'lengths 47 lbs/carton TPO Standing high x 10'in length simulate standing seam metal roof. 30 profiles/carton with Seam Profile profile with pressure .Factory applied adhesive and release connecting dowels sensitive adhesive and liner for easy installation on primed release liner surfaces. •White,Tan,Gray, *Butt end aligned with dowels provided Regal Red,Regal with the profiles Blue,Hartford Green Freedom 5'-0" •45 mil and 60 mil -Eliminates wasted membrane because 5'z 50' 76 lbs Dual HW(Heat reinforced membranes of the two HW edges. Weld)Flashing -6"HW edge allows for more flexibility and easier installation EverGuard •8"diameter nominal *For use in flashing outside comer of 20 Comers/carton 3 lbs/carton TPO 50 mil non-reinforced base and curb flashings Fluted Corner TPO membrane [/9/2009 Product Data Sheet EverGuard® TPO Accessories Description The GAF Everguard®TPO single-ply roofing system includes aEextensive line of EverGuard TPO flashing accessories for use with EverGuard TPO roofing systems.EverGuard flashing accessories are heat welded to the EverGuard roofing membrane. They are easy to install and provide secure protection from roof edge to parapet to penetration to wall. The following EverGuard TPO flashing accessories are ava`kble in standard colors of white, gray and tan unless otherwise noted. Product Description Benefit/Application Quantity/Size Weight Preformed •75 mil molded •One standard size accommodates •Fits V-6"diameter 9 lbs/carton Vent Boots membrane most common pipes and conduits pipes •Supplied with stainless steel •6 Vent Boots per carton clamping rings Preformed •60 mil thick molded •Universal style corner accommodates •4"x 4"with 6"flange 6 lbs/carton Corners membrane both inside and outside comers of base •20 Comers per carton and curb flashings UN-55 •55 mil thick •Alternative flashing/reinforcement •24"x 50'roll 28 lbs/roll Detailing umeinforced material for penetrations and comers Membrane membrane •Required wherever preformed vent •White,Tan,Gray, boots cannot be used Regal Red,Regal Blue,Hartford Green (Energy Tan in the West) TPO 45 mil •45 mil thick •Use for stripping in coated metal •8"x 100'roll 18 lbs/roll Utility Flashing reinforced membrane flanges Strip •White,Tan,Gray, Regal Red,Regal Blue,Hartford Green (Energy Tan in the West) Coated Metal •24 gauge steel with a •TPO membrane is laminated to •4'x 10'sheets 47 lbs/sheet Sheets 25 mil thick galvanized sheet metal . 10 or 30 sheets per membrane film •Cuts and forms like standard sheet pallet •White,Tan,Gray, metal Regal Red,Regal •Field and flashing TPO membrane heat Blue,Hartford Green welds directly to coated metal (Energy Tan in the •For metal gravel stop and drip edges, West) metal base and curb flashing,sealant pans and scupper sleeves UN-55 T-Joint •55 mil thick •Conforming membrane seal for use •100 patches per box 9 lbs Cover Patches unreinforced over T-Joints in 60 and 80 mil membrane membrane applications Cut •Solvent-based liquid •Sealant provided in squeeze bottle for • 1 pint bottle 24 lbs/carton Edge Sealant sealant use along all cut reinforced edges •12 bottles/carton •Clear •100 lineal feet per pint @ 1/8"diameter bead Walkway Rolls •125 mil extruded and •Herringbone traction surfacing in gray •30"x 50' 118 lbs/roll embossed TPO color •Gray Only •Available in rolls •Heat welds directly to membrane or installed with seam tape Notes: 1.Mass and dimensions stated are nominal unless otherwise indicated. 2. Store accessory flashing materials in original carton,rolls,or sheets on pallets or shelving in a dry area. 1/9/2009 GAF f4verGuardTm S/NGLE-PLY ROOF/NG SYSTEMS To adhered membrane to curbs and walls Description EverGuard® 1 121 Bonding Adhesive is a contact-type bonding adhesive specially designed for bonding TPO single ply roofing membranes and 02 1flashings to various roofing substrates. EverGuard® 1 121 Bonding Adhesive is ageneral purpose rubber-based bonding adhesive for attaching TPO-based single-ply membranes to various substrates, including G of isoc anurate insulation and �•�°``�'--O.�•..--"""- g Y Y gypsum-based cover boards. Features and Benefits A-b., , • Excellent coverage up to 70 sq ft ,,� `���;�• per gallon of bonded membrane ;�`�` i��'g / • Fast-drying solvent system �`�" .�, '' • Easy application using roller or brush • Spray application also possible • High initial tack • Physical Properties 1121 Bonding OBase: Synthetic polymer Adhesive ^/•1I Solvent: Hydrocarbon blend Flash Point: 0°F (-18'Q Weight/Gallon: 7.4 lbs Color: Yellow Ordering Information Viscosity: 2,300- 2,700 cps Coverage: 50.70 sq. ft./gallon Item Number: 778000M Packaging: 5 gallon pails Total Solids: 25% +/- 2.5% Weight: 37 lbs/pail Voc: 611 grams/liter Shipping: 45 pails per pallet Shelf Life: 1 year, unopened Open Time: Up to 60 minutes Dry Time: 5- 15 minutes Application: Roller, brush, or spray RoofingQuality You Can Trust..From North America's Largest „ 02014 GAF•4/14•#468•1361 Alps Road•Wayne,NJ 07470 COMEG142 OFFICE COPY MEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION • • • GAF Evaluation Report 01506.09.05-1130 1 Campus Drive FL5293-R29 Parsippany, NJ 07054 Date of Issuance: 11/09/2005 (800)766-3411 Revision 30:06/15/2018 SCOPE: — This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: EverGuard®TPO Single-Ply Roof Membrane Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 99-page Appendix. Prepared by: — Pt Robert J.M. Nieminen, P.E. `.-s-t.'=; ;?4' Florida Registration No.59166 Florida DCA ANE1983 ^%�S�t' =^n r,'_ The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 06/15/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Single Ply Roof Systems Compliance Statement: EverGuard® TPO Single-Ply Roof Membrane Systems, as produced by GAF, have demonstrated compliance with the following sections of the 6' Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.13.2 Physical Properties ASTM D6878 2011 1523.6.2 Wind TAS 114 2011 3. REFERENCES: Entity Exam Reference Date Entit Exam Reference Date ACRC(TST4671) TAS 114 06-035 10/18/2006 FM App(TST1867) FM 4474 797-09594-267 06/24/2014 ACRC(TST4671) TAS 114 07-005 01/17/2007 FM App(TST1867) FM 4474 797-09635-267 07/16/2014 ACRC(TST4671) TAS 114 07-024 03/01/2007 FM App(TST1867) FM 4474 797-09892-267 10/30/2014 ACRC(TST4671) TAS 114 07-016 04/19/2007 FM App(TST1867) FM 4474 797-10123-283 12/17/2014 ACRC(TST4671) TAS 114 07-017 04/19/2007 FM App(TST1867) FM 4474 797-10153-267 12/19/2014 ACRC(TST4671) TAS 114 07-025 05/02/2007 FM App(TST1867) FM 4474 797-10210-267 02/05/2015 ACRC(TST4671) TAS 114 07-026 05/03/2007 FM App(TST1867) FM 4474 797-10211-267 02/05/2015 ACRC(TST4671) TAS 114 07-027 05/04/2007 FM App(TST1867) FM 4474 797-10212-267 02/05/2015 ACRC(TST4671) TAS 114 07-042 08/31/2007 FM App(TST1867) FM 4474 797-RR20018 02/23/2015 ACRC(TST4671) TAS 114 07-043 09/05/2007 FM App(TST1867) FM 4474 RR200320 04/07/2015 ACRC(TST4671) TAS 114 07-045 09/06/2007 FM App(TST1867) FM 4474 RR200321 04/07/2015 ACRC(TST4671) TAS 114 07-046 09/06/2007 FM App(TST1867) FM 4474 3055411 04/15/2015 ACRC(TST4671) TAS 114 07-048 09/07/2007 FM App(TST1867) FM 4474 3047636-LTR 06/24/2015 ACRC(TST4671) TAS 114 07-049 09/10/2007 FM App(TST1867) FM 4474 RR202913 11/19/2015 ACRC(TST4671) TAS 114 07-080 01/03/2008 FM App(TST1867) FM 4474 3053501 01/14/2016 ACRC(TST4671) TAS 114 08-022 04/17/2008 FM App(TST1867) FM 4474 3055167 02/10/2016 ACRC(TST4671) TAS 114 08-030 04/05/2008 FM App(TST1867) FM 4474 RR204005 04/13/2016 ACRC(TST4671) TAS 114 08-023 04/17/2008 FM App(TST1867) FM 4474 RR205159 05/05/2016 ACRC(TST4671) TAS 114 08-033 04/19/2008 FM Apo(TST1867) FM 4474 RR205192 05/09/2016 ACRC(TST4671) TAS 114 08-032 04/19/2008 FM App(TST1867) FM 4474 RR205233 06/15/2016 ACRC(TST4671) TAS 114 11-004 03/21/2011 FM App(TST1867) FM 4474 RR205846 07/21/2016 ACRC(TST4671) TAS 114 11-011 03/24/2011 FM App(TST1867) FM 4474 RR205474 08/31/2016 ACRC(TST4671) TAS 114 11-012 04/06/2011 FM App(TST1867) FM 4474 RR206198 09/01/2016 ACRC(TST4671) TAS 114 11-013 04/06/2011 FM App(TST1867) FM 4474 RR206353 09/07/2016 ACRC(TST467 1) TAS 114 11-019 04/08/2011 FM App(TST1867) FM 4474 RR206620 09/12/2016 ACRC(TST4671) TAS 114 11-020 04/08/2011 FM App(TST1867) FM 4474 RR206351 10/21/2016 ACRC(TST4671) TAS 114 11-021 04/11/2011 FM App(TST1867) FM 4474 3055491 12/05/2016 ACRC(TST4671) TAS 114 11-040 08/05/2011 FM App(TST1867) FM 4474 3058483 12/09/2016 ACRC(TST4671) TAS 114 11-041 08/05/2011 FM App(TST1867) FM 4474 3056728 LTR 12/23/2016 ACRC(TST4671) TAS 114 11-056 09/30/2011 FM App(TST1867) FM 4470 3056822 LTR 01/04/2017 ACRC(TST4671) TAS 114 12-008 04/10/2012 FM App(TST1867) FM 4474 RR208456 02/13/2017 ACRC(TST4671) TAS 114 12-012 04/23/2012 FM App(TST1867) FM 4474 3061218 05/10/2017 ACRC(TST4671) TAS 114 12-013 04/23/2012 FM App(TST1867) FM 4474 3061218 LTR 05/16/2017 ACRC(TST4671) TAS 114 12.014 04/23/2012 FM App(TST1867) FM 4474 RR209927 06/23/2017 ACRC(TST4671) TAS 114 12-016 04/24/2012 FM App(TST1867) FM 4474 RR210305 07/13/2017 ACRC(TST4671) TAS 114 12-019 04/25/2012 FM App(TST1867) FM 4474 RR212730 04/05/2018 ACRC(TST4671) TAS 114 12-024 05/09/2012 FM App(TST1867) FM 4474 PR449797 04/24/2018 ACRC(TST4671) TAS 114 12-025 05/09/2012 FM App(TST1867) FM 4474 RR213333 04/25/2018 ACRC(TST4671) TAS 114 12-029 05/23/2012 IRT(TST7408) TAS 114 02-008 01/18/2002 ACRC(TST4671) TAS 114 12-030 05/23/2012 IRT(TST7408) TAS 114 03-0728 02/17/2004 ACRC(TST4671) TAS 114 11-042-R1 01/27/2012 IRT(TST7408) TAS 114 04-012 02/18/2004 ACRC(TST4671) TAS 114 12-033 08/10/2012 1RT(TST7408) TAS 114 04-019 04/26/2004 ACRC(TST4671) TAS 114 12-036 08/13/2012 PRI(TST5878) Physicals GAF-373-02-01 10/15/2012 ACRC(TST4671) TAS 114 12-018-R1 01/30/2013 PRI(TST5878) FM 4474 GAF-043-02-03 09/16/2013 ACRO(TST4671) TAS 114 08-022-R1 01/15/2015 PRI(TST5878) FM 4474 GAF-043-02-04 09/16/2013 NEMO ETC,LLC Evaluation Report 01506.09.05-R30 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5293-R29 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 30:06/15/2018 Page 2 of 6 ONEMO I etc. Entity Exam Reference Date Entity Exam Reference Date ACRC(TST4671) TAS 114 11-056-R2 01/23/2015 PRI(TST5878) Physicals GAF-421-02-01 10/22/2013 ACRC(TST4671) TAS 114 16-002 03/04/2016 PRI(TST5878) Physicals GAF-422-02-01 10/22/2013 ATI(TST1558) TAS 114 H-3320.01-109-44 08/10/2017 PRI(TSTS878) Physicals GAF-424-02-01 11/11/2013 ATI(TST1558) TAS 114 H3314.01-109-44 08/14/2017 PRI(TST5878) Physicals GAF-425-02-01 11/11/2013 ATI(TST1558) TAS 114 H-3315.01-109-44 08/14/2017 PRI(TST5878) Physicals GAF-462-02-02 11/18/2013 ATI(TST1558) TAS 114 H-3317.01-109-44 08/14/2017 PRI(TST5878) FM 4474 GAF-457-02-02 01/20/2014 ATI(TST1558) TAS 114 H-3318.01-109-44 08/14/2017 PRI(TST5878) FM 4474 GAF-457-02-04 01/24/2014 ATI(TST1558) TAS 114 H-0730.01-109-44 08/16/2017 PRI(TST5878) FM 4474 GAF-457-02-06 01/24/2014 ERD(TST6049) TAS 114 SC8580.11.15-4 11/09/2015 PRI(TST5878) FM 4474 GAF-457-02-07 01/24/2014 ERD(TST6049) FM 4474 SC8580.11.15-2 11/18/2015 PRI(TST5878) FM 4474 GAF-457-02-08 01/24/2014 ERD(TST6049) Criticality SC16505.17 09/22/2017 PRI(TST5878) Physicals GAF-423-02-01 01/27/2014 ERD(TST6049) FM 4474 SC16825.12.17-1 12/31/2017 PRI(TST5878) Physicals GAF-426-02-01 01/27/2014 ERD(TST6049) FM 4474 SC16825.12.17-3B 12/31/2017 PRI(TST5878) Rupture GAF-435-02-01 01/29/2014 F-TEC(TST7393) TAS 114 08-050183 06/26/2008 PRI(TST5878) FM 4474 GAF-435-02-07 01/29/2014 F-TEC(TST7393) TAS 114 08-050184 06/26/2008 PRI(TST5878) FM 4474 GAF-435-02-08 01/29/2014 F-TEC(TST7393) TAS 114 08-070133 08/04/2008 PRI(TST5878) FM 4474 GAF-435-02-09 01/29/2014 F-TEC(TST7393) TA5 114 08-050185 10/14/2008 PRI(TST5878) FM 4474 GAF-435-02-10 01/29/2014 F-TEC(TST7393) TAS 114 08-072805 02/16/2009 PRI(TST5878) FM 4474 GAF-435-02-11 01/29/2014 FM App(TST1867) FM 4470 3003617 12/20/1999 PRI(TST5878) FM 4474 GAF-506-02-06 03/06/2014 FM App(TST1867) FM 4470 3009026 06/18/2002 PRI(TST5878) FM 4474 GAF-506-02-08 03/06/2014 FM App(TST1867) FM 4470 3013861 03/28/2003 PRI(TST5878) FM 4474 GAF-506-02-10 03/06/2014 FM App(TST1867) FM 4470 3014692 08/05/2003 PRI(TST5878) FM 4474 GAF-510-02-02 04/08/2014 FM App(TST1867) FM 4470 3014955 01/22/2004 PRI(TST5878) FM 4474 GAF-510-02-04 04/08/2014 FM App(TST1867) FM 4470 3012721 02/11/2004 PRI(TST5878) FM 4474 GAF-510-02-05 04/08/2014 FM App(TST1867) FM 4470 3015029 02/19/2004 PRI(TST5878) FM 4474 GAF-511-02-02 04/08/2014 FM App(TST1867) FM 4470 3015578 03/12/2004 PRI(TST5878) FM 4474 GAF-506-02-11 04/14/2014 FM App(TST1867) FM 4470 3020588 03/24/2004 PRI(TST5878) FM 4474 GAF-506-02-12 04/14/2014 FM App(TST1867) FM 4470 3019881 03/20/2004 PRI(TST5878) FM 4474 GAF-506-02-13 04/14/2014 FM App(TST1867) FM 4470 3016068 04/02/2004 PRI(TST5878) FM 4474 GAF-506-02-14 04/14/2014 FM App(TST1867) FM 4470 3013861 05/21/2004 PRI(TST5878) FM 4474 GAF-506-02-01 04/22/2014 FM App(TST1867) FM 4470 3105578 05/12/2004 PRI(TST5878) FM 4474 GAF-514-02-01 05/12/2014 FM App(TST1867) FM 4470 3014955 01/28/2005 PRI(TST5878) FM 4474 GAF-514-02-03 05/12/2014 FM App(TST1867) FM 4470 3022136 03/17/2005 PRI(TST5878) FM 4474 GAF-514-02-04 05/12/2014 FM App(TST1867) FM 4470 3020681 09/01/2005 PRI(TST5878) FM 4474 GAF-514-02-05 05/12/2014 FM App(TST1867) FM 4470 3024051 03/28/2006 PRI(TST5878) FM 4474 GAF-514-02-07 05/12/2014 FM App(TST1867) FM 4470 797-02093-267 04/26/2006 PRI(TST5878) FM 4474 GAF-514-02-08 05/12/2014 FM App(TST1867) FM 4470 3023458 07/18/2006 PRI(TST5878) FM 4474 GAF-516-02-01 05/13/2014 FM App(TST1867) FM 4470 3028039 09/11/2006 PRI(TST5878) FM 4474 GAF-516-02-03 05/13/2014 FM App(TST1867) FM 4470 3027159 10/03/2006 PRI(TST5878) FM 4474 GAF-516-02-02 06/06/2014 FM App(TST1867) FM 4470 3026149 02/05/2007 PRI(TST5878) FM 4474 GAF-525-02-02 06/23/2014 FM App(TST1867) FM 4470 3026964 07/25/2007 PRI(TST5878) FM 4474 GAF-525-02-03 06/23/2014 FM App(TST1867) FM 4470 3028857 11/02/2007 PRI(TST5878) FM 4474 GAF-462-02-09 07/01/2014 FM App(TST1867) FM 4470 3030199 11/05/2007 PRI(TST5878) FM 4474 GAF-462-02-10 07/01/2014 FM App(TST1867) FM 4470 3030813 11/05/2007 PRI(TST5878) FM 4474 GAF-462-02-11 07/01/2014 FM App(TST1867) FM 4470 3031262 11/30/2007 PRI(TST5878) FM 4474 GAF-524-02-02 07/01/2014 FM App(TST1867) FM 4470 3030292 02/25/2008 PRI(TST5878) FM 4474 GAF-524-02-03 07/01/2014 FM App(TST1867) FM 4470 797-03825-267 07/21/2008 PRI(TST5878) FM 4474 GAF-524-02-05 07/01/2014 FM App(TST1867) FM 4470 3033314 08/26/2008 PRI(TST5878) FM 4474 GAF-540-02-02 08/06/2014 FM App(TST1867) FM 4470 3034749 10/16/2008 PRI(TST5878) FM 4474 GAF-540-02-03 08/06/2014 FM App(TST1867) FM 4470 3032856 11/24/2008 PRI(TST5878) FM 4474 GAF-540-02-04 08/06/2014 FM App(TST1867) FM 4470 3033135 11/24/2008 PRI(TST5878) FM 4474 GAF-538-02-02 08/13/2014 FM App(TST1867) FM 4470 3033862 12/24/2008 PRI(TST5878) FM 4474 GAF-538-02-03 08/13/2014 FM App(TST1867) FM 4470 3034394 02/27/2009 PRI(TST5878) FM 4474 GAF-532-02-01 08/22/2014 FM App(TST1867) FM 4470 3033121 04/13/2009 PRI(TST5878) FM 4474 GAF-524-02-05 08/27/2014 FM App(TST1867) FM 4470 3035300 05/06/2009 PRI(TST5878) FM 4474 GAF-549-02-01 08/08/2014 FM App(TST1867) FM 4470 3036614 06/09/2009 PRI(TST5878) FM 4474 GAF-538-02-04 09/02/2014 FM App(TST1867) FM 4470 3034310 06/15/2009 PRI(TST5878) FM 4474 GAF-559-02-11 10/16/2014 FM App(TST1867) FM 4470 3036141 08/10/2009 PRI(TST5878) FM 4474 GAF-559-02-12 10/16/2014 FM App(TST1867) FM 4470 3037820 04/30/2010 PRI(TST5878) FM 4474 GAF-559-02-13 10/16/2014 FM App(TST1867) FM 4470 797-059797-267 08/18/2010 PRI(TST5878) FM 4474 GAF-559-02-14 10/16/2014 FM App(TST1867) FM 4470 3038215 09/02/2010 PRI(TST5878) FM 4474 GAF-559-02-15 10/16/2014 FM App(TST1867) FM 4470 797-05901-267 10/01/2010 PRI(TST5878) FM 4474 GAF-559-02-16 10/16/2014 FM App(TST1867) FM 4470 797-06003-267 11/11/2010 PRI(TST5878) FM 4474 GAF-559-02-18 10/16/2014 FM App(TST1867) FM 4470 3038318 12/10/2010 PRI(TST5878) FM 4474 GAF-538-02-05 12/03/2014 FM App(TST1867) FM 4470 797-06178-267 02/07/2011 PRI(TST5878) Physicals GAF-584-02-01 12/07/2015 FM App(TST1867) FM 4470 3040234 02/23/2011 PRI(TST5878) Physicals GAF-585-02-01 12/07/2015 FM App(TST1867) FM 4470 3040377 03/08/2011 PRI(TST5878) Physicals GAF-586-02-01 12/07/2015 FM App(TST1867) FM 4470 3041685 03/24/2011 PRI(TST5878) FM 4474 GAF-453-02-05 05/06/2016 FM App(TST1867) FM 4470 797-06254-267 03/24/2011 PRI(TST5878) FM 4474 GAF-453-02-09 05/06/2016 FM App(TST1867) FM 4470 3041535 06/08/2011 PRI(TST5878) Physicals GAF-653-02-01 10/20/2016 NEMO ETC,LLC Evaluation Report 01506.09.05-R30 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5293-R29 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 30:06/15/2018 Page 3 of 6 NMEMO I etc. Entity Exam Reference Date Entity Exam Reference Date FM App(TST1867) FM 4470 797-06537-267 06/13/2011 PRI(TST5878) FM 4474 GAF-653-02-04 10/20/2016 FM App(TST1867) FM 4470 797-06538-267 06/13/2011 PRI(TST5878) FM 4474 GAF-746-02-01 12/14/2016 FM App(TST1867) FM 4470 3041746 08/17/2011 PRI(TST5878) FM 4474 GAF-746-02-02 12/14/2016 FM App(TST1867) FM 4470 797-06894-267 11/02/2011 PRI(TST5878) FM 4474 GAF-746-02-05 12/14/2016 FM App(TST1867) FM 4470 3038278 11/18/2011 PRI(TST5878) FM 4474 GAF-746-02-06 12/14/2016 FM App(TST1867) FM 4470 3042905 01/10/2012 PRI(TST5878) FM 4470 GAF-755-02-01 02/02/2017 FM App(TST1867) FM 4470 797-07041-267 02/27/2012 PRI(TSTS878) FM 4474 GAF-755-02-02 02/02/2017 FM App(TST1867) FM 4470 797-07183-267 03/01/2012 PRI(TST5878) FM 4474 GAF-755-02-03 02/02/2017 FM App(TST1867) FM 4470 3044506 03/28/2012 PRI(TST5878) FM 4474 GAF-755-02-04 02/02/2017 FM App(TST1867) FM 4470 797-07331-267 04/13/2012 PRI(TST5878) Physicals GAF-700-02-01 03/10/2017 FM App(TST1867) FM 4470 3044862 05/11/2012 PRI(TST5878) FM 4474 GAF-782-02-01 08/24/2017 FM App(TST1867) FM 4470 797-07455-267 05/31/2012 PRI(TST5878) FM 4474 GAF-782-02-02 08/30/2017 FM App(TST1867) FM 4470 797-07474-267 06/11/2012 PRI(TST5878) FM 4474 GAF-776-02-02 10/04/2017 FM App(TST1867) FM 4470 797-07476-267 06/21/2012 PRI(TST5878) Criticality GAF-793-02-01 12/08/2017 FM App(TST1867) FM 4470 3045789 07/12/2012 PRI(TST5878) FM 4474 GAF-793-02-02 12/08/2017 FM App(TST1867) FM 4470 3045863 08/16/2012 PRI(TST5878) FM 4474 GAF-793-02-04 12/08/2017 FM App(TST1867) FM 4470 3041749 08/23/2012 PRI(TST5878) FM 4474 GAF-835-02-02 02/19/2018 FM App(TST1867) FM 4470 3046328 09/13/2012 PRI(TST5878) FM 4474 GAF-834-02-01 02/28/2018 FM App(TST1867) FM 4470 3041769 09/27/2012 PRI(TST5878) FM 4474 GAF-835-02-03 02/28/2018 FM App(TST1867) FM 4470 797-07744-267 10/17/2012 PRI(TST5878) FM 4474 GAF-835-02-04 02/28/2018 FM App(TST1867) FM 4470 797-07885-267 11/21/2012 PRI(TST5878) FM 4474 GAF-833-02-01 03/02/2018 FM App(TST1867) FM 4470 3046054 12/21/2012 PRI(TST5878) FM 4474 GAF-833-02-02 03/02/2018 FM App(TST1867) FM 4470 797-08216-267 04/11/2013 PRI(TST5878) FM 4474 GAF-836-02-01 03/02/2018 FM App(TST1867) FM 4470 3048122 04/29/2013 PRI(TST5878) FM 4474 GAF-836-02-02 03/02/2018 FM App(TST1867) FM 4470 797-08217-267 05/01/2013 PRI(TST5878) FM 4474 GAF-836-02-03 03/02/2018 FM App(TST1867) FM 4470 797-08264-267 05/23/2013 PRI(TST5878) FM 4474 GAF-836-02-04 03/02/2018 FM App(TST1867) FM 4470 3047237 07/15/2013 PRI(TST5878) FM 4474 GAF-858-02-05 04/27/2018 FM App(TST1867) FM 4470 3047636 08/08/2013 PRI(TST5878) FM 4474 GAF-858-02-01 05/01/2018 FM App(TST1867) FM 4474 797-08873-267 11/26/2013 PRI(TST5878) FM 4474 GAF-858-02-02 05/01/2018 FM App(TST1867) FM 4474 3048066 12/13/2013 PRI(TST5878) FM 4474 GAF-858-02-03 05/01/2018 FM App(TST1867) FM 4474 3041749 12/30/2013 PRI(TST5878) FM 4474 GAF-858-02-04 05/01/2018 FM App(TST1867) FM 4474 797-09116-267 01/24/2014 PRI(TST5878) FM 4474 GAF-858-02-06 05/01/2018 FM App(TST1867) FM 4474 797-09234-267 03/11/2014 PRI(TST5878) Physicals GAF-870-02-01 06/05/2018 FM App(TST1867) FM 4474 797-09317-267 04/18/2014 UL,LLC(QUA9625) CA Inspect,R3306(TX) 10/20/2016 FM App(TST1867) FM 4474 797-09493-267 05/27/2014 UL,LLC(QUA9625) CIA Inspect,R1306(IN) 10/27/2016 FM App(TST1867) FM 4474 797-09495-267 05/27/2014 UL,LLC(QUA9625) CA Inspect,R1306(MA) 10/18/2016 FM App(TST1867) FM 4474 797-09573-267 06/13/2014 UL,LLC(QUA9625) CIA Inspect,R1306(UT) 12/01/2016 FM App(TST1867) FM 4474 797-09497-267 06/23/2014 UL,LLC(QUA9625) QA Inspect,R1306(PA) 04/19/2018 i PRODUCT DESCRIPTION: This Evaluation Report covers EverGuard®TPO Single-Ply Roof Membrane Systems installed in accordance with GAF published installation instructions and the Limitations/Conditions of Use herein. 4.1 EverGuard° TPO membranes are nominal 45-mil (1.1 mm), 60-mil (1.52-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic polyolefin roof covers supplied. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully-adhered to Approved substrates. 4.2 EverGuard Extreme' TPO membranes are nominal 50-mil (1.27-mm), 60-mil (1.52-mm), 70-mil (1.8) or 80-mil (2.0 mm)thick, internally reinforced thermoplastic polyolefin roof covers supplied. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully-adhered to Approved substrates. 4.3 EverGuard® TPO FB Ultra membranes are nominal 45--mil (1.1 mm), 60-mil (1.52-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic (TPO) roof covers with a polyester fleece backing. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully-adhered to Approved substrates. 4.4 EverGuard Extreme` TPO FB Ultra membranes are nominal 50-mil (1.27-mm), 60-mil (1.52-mm), 70-mil (1.8) or 80- mil (2.0 mm) thick, internally reinforced thermoplastic (TPO) roof covers with a polyester fleece backing. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully-adhered to Approved substrates. 4.5 EverGuard` Freedom'm TPO HW and EverGuard° FreedomTm TPO with RapidSeamTm Technology membranes are nominal 45-mil (1.1 mm) or 60-mil (1.52-mm)thick, internally reinforced thermoplastic (TPO) roof covers with a self- adhering backing. EverGuard® FreedomTm TPO HW laps are sealed using hot air welding. EverGuard® Freedom'"'TPO with Rapid Seam'"'Technology laps are self-adhering. The roof cover is self-adhered to Approved substrates. NEMO ETC,LLC Evaluation Report 01506.09.05-R30 Certificate of Authorization#31455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5293-R29 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 30:06/15/2018 Page 4 of 6 NNEMOletc. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2)or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. NEMO ETC,LLC Evaluation Report 01506.09.05-R30 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5293-R29 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 30:06/15/2018 Page 5 of 6 ONEMOletc. 6. INSTALLATION: 6.1 EverGuard®TPO Single-Ply Roof Membrane Systems shall be installed in accordance with GAF published installation instructions,subject to the Limitations/Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact named QA entity for details on manufacturing facilities covered for QA under F.A.C. Rule 611320-3 requirements. QUALITY9. UL, LLC—QUA9625;(847)664-3281; k.chancellor@ul.com -THE 99-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 01506.09.05-R30 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5293-1129 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 30:06/15/2018 Page 6 of 6 ONEMOjetc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 113 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-9 1C Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 9-10 11) Wood New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 11 1E Wood New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 11-12 11' Wood New,Reroof(Tear-Off)or Recover C-2 Plate-Bonded Roof Cover 13 1G Wood New,Reroof(Tear-Off)or Recover D-1 Insulated,Mechanically Attached Roof Cover 14 1H Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 14 11 Wood New,Reroof(Tear-Off)or Recover E-1 Non-Insulated,Mechanically Attached Roof Cover 14 L Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 15-17 2A Steel New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 18 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 18-24 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Base and Cap Ply 25 21) Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-2 Mech.Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 26-27 2E Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 28-40 2F Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Base and Cap Ply 41 2G Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1A Thermal Barrier with Vapor Barrier,Mechanically Attached Insulation,Bonded Roof Cover 42-46 2H Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 47-49 21 Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-1 Insulated,Mechanically Attached Roof Cover 50-51 2.1 Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 52 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 53-63 3B Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Base and Cap Ply 63 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 63 4A Lightweight concrete New or Reroof(Tear-Off) A-1 LWC to Deck,Bonded Insulation,Bonded Roof Cover 64-65 46 Lightweight concrete New or Reroof(Tear-Off) A-2 LWC to Deck,Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 66 4C Lightweight concrete New or Reroof(Tear Off) E LWC to Deck,Mechanically Attached Base Sheet,Bonded Roof Cover 67-68 4D Lightweight concrete New or Reroof(Tear Off) F LWC to Deck,Bonded Roof Cover 69-71 4E Lightweight concrete New or Reroof(Tear Off) F Temp Roof/Vapor Barrier to Deck,LWC to Temp Roof/Vapor Barrier,Bonded Roof Cover 71 5A Cementious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 72 5B Cementious wood fiber New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 73 Sc Cementious wood fiber New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 73 5D Cementious wood fiber New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 73 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 74-75 66 Gypsum Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 76 6C Gypsum Reroof(Tear-Off) B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 76-78 6D Gypsum Reroof(Tear-Off) C-1 Mechanically Attached Insulation,Bonded Roof Cover 79 6E Gypsum Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 80 6F Gypsum Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 80 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 81-95 713 Wood or Steel Recover C-2 Plate-Bonded Roof Cover 96-97 7C Steel Recover D-1 Insulated,Mechanically Attached Roof Cover 98 7D Various Recover F Non-Insulated,Bonded Roof Cover 99 NEMO ETC,LLC Evaluation Report 01506.09.05-1130 for F15293-1129 Certificate of Authorization#32455 6'h Edition(2017)FBC NON-HVHZ EVALUATION Revision 30:06/15/2018 Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 1 of 99 ONEMOjetc. The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted,fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Drill-Tec#12 Fastener or Drill-Tec#14 Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate(Flat)or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only),Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate.Min.0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: Drill-Tec#12 Fastener,Drill-Tec#14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate(Flat)or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only). Minimum 0.75-inch steel penetration,engage the top flute of the steel deck. ➢ Structural Concrete: Drill-Tec#14 Fastener or Drill-Tec CD-10 with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate(Flat)or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only)or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate.Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral wool roof board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. Refer to GAF published installation instructions for details and requiremepts regarding the use of polystyrene insulation in EverGuard®roofing systems: Insulation: High Traffic Applications: Recover Applications: ➢ Expanded polystyrene(EPS)meeting or exceeding ASTM CS78,Type ➢ Extruded polystyrene(XPS) meeting or exceeding ASTM C578,Type ➢ XPS Fan-Fold Recover Board with plastic facer meeting or exceeding II, nominal 1.5 Ib/ft2 density and minimum 15 psi compressive IV,minimum 1-inch thick and minimum 25 psi compressive strength. ASTM C578,Type IV,3/8-inch thick and minimum 25 psi compressive strength. ➢ Expanded polystyrene(EPS)with plastic facer meeting or exceeding strength. ➢ Expanded polystyrene(EPS)with plastic facer meeting or exceeding ASTM C578, Type IX, minimum 1-inch thick and minimum 25 psi ➢ EPS Recover Board meeting or exceeding ASTM C578,Type IV, 1/2- ASTM C578,Type II,nominal 1.5 Ib/ft2 density and minimum 15 psi compressive strength. inch thick and minimum 25 psi compressive strength. compressive strength. ➢ EPS Recover Board with plastic facer meeting or exceeding ASTM C578, Type II, 1/2-inch thick and minimum 15 psi compressive strength. FireOut'"Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection or VersaShield®Solo'"Fire-Resistant Slip Sheet,installed in accordance with GAF published installation instructions and fire resistance certification listings,may be used as a non-load-bearing,fire-barrier/slip-sheet component within any system outlined herein. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete(LWIC)may be substituted for or installed below the rigid insulation board for System Type C-1(mechanically attached insulation,bonded roof cover),System Type C-2(plate-bonded roof cover)or System Type D(mechanically attached membrane),whereby the insulation or membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. For Type C-1,the top insulation layer shall be that specified in the applicable Table. For Type C-2 or D if the LWIC is installed below,the rigid insulation board may consist of min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard HD Polyiso Insulation,EnergyGuard NH HD Polyiso Insulation,EnergyGuard HD Plus Polyiso Insulation,EnergyGuard NH HD Plus Polyiso Insulation,EnergyGuard RH HD Polyiso Insulation or Structociek High Density Fiberboard Roof Insulation or min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board,SECUROCK Glass-Mat Roof Board. The structural deck shall be of equal or greater type,thickness and strength to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-relatated issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot Asphalt(HA): Full mopping,25-30 lbs/square. ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): Continuous 2.5 to 3.5-inch ribbons,12-inch o.c. ➢ LRF Adhesive M(LRF-M): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ OlyBond Adhesive Fastener(Classic): Full coverage,1 gal/square. ➢ OlyBond 500(06500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.using PaceCart,SpotShot or Canister delivery methods. Note:OlyBond Classic or OlyBond 500 Green may be used in place of OlyBond 500 when used to bond insulation or coverboards. NEMO ETC,LLC Evaluation Report 01506.09.05-R30 for FL5293-R29 Certificate of Authorization#32455 6"Edition(2017)FBC NON-HVHZ EVALUATION Revision 30:06/15/2018 Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 2 of 99 NNEMOletc. ➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ Hot Asphalt(HA): MDP= -240.0 psf (Min.0.5-inch thick) ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): MDP= -117.5 psf (Min.1.0-inch thick) ➢ LRF Adhesive M(LRF-M): MDP= -232.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation) ➢ OlyBond 500(013500): MDP= -315.0 psf (Min.0.5-inch thick EnergyGuard RH or RN) ➢ OlyBond 500(013500): MDP= -487.5 psf (Min.0.5-inch thick EnergyGuard RA) ➢ OlyBond 500(OB500): MDP= -292.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For System Type D,steel deck applications,the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For Recover Applications using System Type C-2 or any System Type D,the insulation is optional. Alternatively,a separator board may be installed prior to roof cover installation when using System Type C-2 or any System Type D or a separator sheet may be installed prior to roof cover installation when using any System Type D. The existing roof system shall be suitable for a recover application. The separator component shall be documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. ➢ Separator Board Options for Recover System Type C-2 or System Type D: Min.0.5-inch EnergyGuard Polyiso Insulation,EnergyGuard NH Polyiso Insulation,EnergyGuard RA,EnergyGuard RN,EnergyGuard Ultra Polyiso Insulation,EnergyGuard NH Ultra Polyiso Insulation,Structodeck High Density Fiberboard Roof Insulation,EnergyGuard RH HD Polyiso Insulation,EnergyGuard HD Polyiso Insulation,EnergyGuard NH HD Polyiso Insulation,EnergyGuard HD Plus Polyiso Insulation or EnergyGuard NH HD Plus Polyiso Insulation or min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass- Mat Roof Board. ➢ Separator Sheet Options for Recover System Type D: EverGuard Polymat Separation Layer(3 oz/yd')or EverGuard Polymat Cushioning Layer(6 oz/yd'). 15. Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top- coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. NEMO ETC,LLC Evaluation Report 01506.09.05-R30 for FL5293-R29 Certificate of Authorization#32455 61h Edition(2017)FBC NON-HVHZ EVALUATION Revision 30:06/15/2018 Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 3 of 99 NNEMOletc. 16. For adhesive-applied membrane systems,side laps shall be minimum 3-inch wide sealed with min.1.5-inch heat weld. Unless otherwise noted,membrane adhesive application rates are as follows: GAF ROOF COVER/ADHESIVE COMBINATIONS Membrane Adhesive Method Rate EverGuard TPO#1121 Bonding Adhesive 0.8 to 1.0 gal/square/surface. For use over SECUROCK Gypsum-Fiber Roof Board,the application rate changes to EverGuard TPO (#1121) Contact(both sides) 1.2 to 1.67 gal/sq/surface EverGuard WB181 Bonding Adhesive To polyisocyanurate or Structodek High Density Fiberboard Roof Insulation,Fiber Base HD1 or Fiber Base HD6 at EverGuard TPO (WB181) Contact(both sides) 0.63 gal/square and roof cover underside at 0.21 gal/square. To Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board at 0.63 to 0.75 gal/square and roof cover underside at 0.21 to 0.25 gal/square EverGuard TPO EverGuard Low VOC TPO Bonding Contact(both sides) 0.46 gal/square/surface Adhesive(L-VOC) EverGuard TPO EverGuard TPO 3 Square Low VOC Contact(both sides) 0.84 gal/square/surface Bonding Adhesive(TPO 3-Square) EverGuard TPO FB Ultra Hot asphalt Wet lay(substrate) 25 lbs/square EverGuard TPO FB Ultra EverGuard WB181 Bonding Adhesive Wet lay(substrate) 0.83 to 1.0 gal/square (WB181) EverGuard TPO FB Ultra GAF LRF Adhesive M(LRF-M)or LRF Wet lay(substrate) 1-inch wide ribbons spaced as noted in tables herein. Note:The adhesive ribbons are located directly over the Adhesive O(LRF-0) I adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. EverGuard TPO FB Ultra GAF 2-Part Roofing Adhesive(GAF 2-Part) Wet lay(substrate) "Spatter pattern"at 3.75 lbs/sq. EverGuard TPO FB Ultra OlyBond 500 Canister Wet lay(substrate) "Spatter pattern"at 0.32 gal/square. 17. Vapor barrier options for over structural concrete deck with adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies: VAPOR OPTIONS; Option# Primer TypeVapor Barrier M Attach Insulation Adhesive DP(psf) VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Hot asphalt applied Hot asphalt -360.0 Sheet,GAFGLAS Ply 4,Tri-Ply Ply 4 or GAFGLAS FlexPly 6 VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied GAF 2-Part,12-inch o.c. -169.0 VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied GAF 2-Part,12-inch o.c. -180.0 VB-4. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering GAF 2-Part,12-inch o.c. -250.0 VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer one or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Hot asphalt applied GAF 2-Part,12-inch o.c. -262.5 Sheet,GAFGLAS Ply 4,Tri-Ply Ply 4 or GAFGLAS FlexPly 6 VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part,12-inch o.c. -270.0 VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-M,12-inch o.c. -180.0 VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Hot asphalt applied LRF-M,12-inch o.c. -495.0 Sheet,GAFGLAS Ply 4,Tri-Ply Ply 4 or GAFGLAS FlexPly 6 VB-9. Matrix 307 Premium Asphalt Primer or ASTM D41 primer UnderRoof HT High Temperature Leak Barrier Self-adhering OlyBond 500,12-inch o.c. -37.5 VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OlyBond 500,12-inch o.c. -165.0 VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OlyBond 500,12-inch o.c. -180.0 VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane OlyBond 500,12-inch o.c. -202.5 Adhesive at 1.5 gal/square VB-13. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OlyBond 500,12-inch o.c. -232.5 VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Hot asphalt applied OlyBond 500,12-inch o.c. -352.5 Sheet,GAFGLAS Ply 4,Tri-Ply Ply 4 or GAFGLAS FlexPly 6 NEMO ETC,LLC Evaluation Report 01506.09.05-R30 for FL5293-R29 Certificate of Authorization#32455 6`^Edition(2017)FBC NON-HVHZ EVALUATION Revision 30:06/15/2018 Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 4 of 99 f4NEM0 I etc. 18. Side laps for EverGuard Freedom TPO with RapidSeam Technology are self-adhering. Side laps for EverGuard Freedom TPO HW are heat welded. Unless otherwise noted,reference to EverGuard Freedom TPO in this Appendix relates to either method. 19. The"Triposite Roofing System"noted herein consists of loose-laid GAFGLAS Stratavent Perforated Venting Base Sheet,followed by asphalt-applied two(2)plies of Ruberoid 20 Smooth or three(3)plies of GAFGLAS FlexPly 6,followed by asphalt-applied 80-mil EverGuard TPO FB Ultra with 1-5/8"heat welded side laps. 20. Unless otherwise noted,the"Hybrid Roofing System" noted herein consists of asphalt-applied Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet or GAFGLAS#80 Ultima Base Sheet followed by asphalt-applied EverGuard TPO FB Ultra. 21. EverGuard Extreme TPO may be used as an alternate to EverGuard TPO. EverGuard Extreme TPO FB Ultra may be used as an alternate to EverGuard TPO FB Ultra. 22. The following insulations are interchangeable within the scope of this Evaluation Report: ➢ EnergyGuard Polyiso Insulation b EnergyGuard NH Polyiso Insulation; ➢ EnergyGuard Ultra Polyiso Insulation b EnergyGuard NH Ultra Polyiso Insulation; ➢ EnergyGuard HD Polyiso Insulation b EnergyGuard NH HD Polyiso Insulation; ➢ EnergyGuard HD Plus Polyiso Insulation b EnergyGuard NH HD Plus Polyiso Insulation. 23. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report 01506.09.05-R30 for FL5293-R29 Certificate of Authorization#32455 6`Edition(2017)FBC NON-HVHZ EVALUATION Revision 30:06/15/2018 Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 5 of 99 ONEMOjetc. TABLE 21: STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION, •.. ..RECOVER SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER System N,.TDeck Insulation(Note 14) Roof Cover MDP System No. (Note 1) Type Attach Membrane Fasteners Attachment (Psf) EVERGUARD TPC: Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 18-inch o.c.within 6-inch wide laps spaced 54-inch o.c. 5-312. Grade 80 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 30.0 Min.22 a., Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed g type B, One or more layers,any Prelim. 12-inch o.c.within 6-inch wide laps spaced 114-inch S-313. Grade 33 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates or Drill-Tec Eyehook AccuSeam o.c.and sealed with a 1.5-inch heat weld. -30.0 Plates Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD and Drill-Tec 2 in.Double Barbed 12-inch o.c.in rows spaced max.114-inch o.c. An 8- S-314. Grade 33 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates,Drill-Tec 2-3/8 in.Barbed XHD inch wide cover strip is heat welded over the stress -30.0 Plates,Drill-Tec Eyehook AccuSeam Plates plates. Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch o.c.within 6-inch wide laps spaced 90-inch o.c. 5-315. Grade 33 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 37.5 Min,22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 114-inch 5-316. Grade 40 steel combination,min.1-inch attach EverGuard TPO SXHD Plates o.c.and sealed with a 1.5-inch heat weld. 37.5 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. 12-inch o.c.within 6-inch wide laps spaced 114-inch 5-317. Grade 80 steel combination,min.1.5-inch attach EverGuard TPO Barbed SXHD Plates o.c.and sealed with a 1.5-inch heat weld. 37.5 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 12-inch o.c.within 5-inch wide laps spaced 115-inch 5-318. Grade 80 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates o.c.and sealed with a 1.5-inch heat weld. 37.5 Drill-Tec XHD with Drill-Tec 2 in.Double Barbed Min.22 ga.,type B, One or more layers,any Prelim. XHD Plates or Drill-Tec 2 3/8 in.Barbed XHD 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c. 5-319. EverGuard TPO 45.0 Grade 33 steel combination,min.1-inch attach Plates;or Drill-Tec SXHD with Drill-Tec 2 3/4 in. and sealed with a 1.5-inch heat weld. Barbed SXHD Plates 5-320. Min.22 ga.,type B, Min.200 psi,min.2-inch thick Prelim. or EverGuard XHD Plates,Drill-Tec Eyehook AccuSeam Plates EverGuard TPO Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c. _q5.0 Grade 33 steel cellular lightweight concrete attach TPO FB Ultra or Drill-Tec 2-3/8 in.Barbed XHD Plates and sealed with a 1.5-inch heat weld. Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch o.c.within 6-inch wide laps spaced 66-inch o.c. 5-321. Grade 40 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 45.0 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 90-inch o.c. 5-322. Grade 33 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 45.0 Min.20 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 90-inch o.c. 5-323. Grade 33 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 45.0 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 6-inch o.c.within 5-inch wide laps spaced 114.5-inch 5-324. Grade 80 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates o.c.and sealed with a 1.75-inch heat weld. 45.0 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 114-inch 5-325. Grade 80 steel combination,min.1-inch attach EverGuard TPO SXHD Plates o.c.and sealed with a 1.5-inch heat weld. 45.0 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c. 5-326. Grade 40 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 52.5 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 66-inch o.c. 5-327. Grade 40 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 52.5 NEMO ETC,LLC Evaluation Report 01506.09.05-R30 for FL5293-R29 Certificate of Authorization#32455 61h Edition(2017)FBC NON-HVH2 EVALUATION Revision 30:06/15/2018 Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 50 of 99 ONEMOjetc. TABLE 21: STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER System No. Deck Insulation(Note 14) Roof Cover MDP (Note 1) Type Attach Membrane Fasteners Attachment (psf) Min.22 a., Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed 5-328. B type B, One or more layers,any Prelim. EverGuard TPO XHD Plates,Drill-Tec Eyehook AccuSeam Plates 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c. -52.5 Grade 33 steel combination,min.1-inch attach or Drill-Tec 2 in.Double Barbed XHD Plates and sealed with a 1.5-inch heat weld. Prelim. Drill-Tec#14 or Drill-Tec CD-10 fasteners with One or more layers,any Drill-Tec 2 in.Double Barbed XHD Plates,Drill- 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c. 5-329. Structural concrete combination,min.1.5-inch attach or EverGuard TPO Tec 2-3/8 in.Barbed XHD Plates or Drill-Tec and sealed with a 1.5-inch heat weld. 52.5 OB500 Eyehook AccuSeam Plates Barbed Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in. 6-inch o.c.within 5-inch wide laps spaced 115-inch o.c. 5-330. Grade 80 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates or Drill-Tec 2 in.Double Barbed XHD and sealed with a 1.5-inch heat weld. -52.5 Plates Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 6-inch o.c.within 6-inch wide laps spaced 54-inch o.c. 5-331. Grade 33 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 60.0 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c. 5-332. Grade 40 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 60.0 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 6-inch o.c.within 6-inch wide laps spaced 90-inch o.c. 5-333. Grade 33 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 60.0 Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c. 5-334. Grade 33 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 60.0 Min.22 ga.,type B, Min.200 psi,min.2-inch thick Prelim. Guard EverGuard TPO Drill-Tec XHD with Drill-Tec 2-3/4 in.SXHD 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c. 5-335. or Ever Grade 33 steel cellular lightweight concrete attach or E er Ultra Plates and sealed with a 1.5-inch heat weld. _67.5 TPOMin.22 ga.,type BV Min.330 psi,min.2-inch thick Drill-Tec XHD with Drill-Tec 2 in.Double Barbed Fastened through to engage steel deck,6-inch o.c. 5-336. (0.5%),Grade 33 steel Celcore Cellular Concrete N/A EverGuard TPO XHD Plates(to engage steel deck) within 6-inch wide laps spaced 114-inch o.c.and sealed -67.5 with a 1.5-inch heat weld. Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c. 5-337. Grade 33 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 67.5 One or more layers,min.1.5- 5 fasteners Min.18 ga.,type B, /plates Drill-Tec XHD Fasteners with Drill-Tec 2 in. 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c. 5-338. Grade 33 steel inch nsulaEtionbon,yEnergGuard Polyiso per 4 x 4 ft EverGuard TPO Double Barbed XHD Plates and sealed with a 1.5-inch heat weld. 90.0 IEnergyGuard Ultra board EVERGUARD TPO FB ULTRA: Min.22 ga.,type B, Drill-Tec XHD(steel only)or Drill-Tec#14 One or more layers,any Prelim. EverGuard TPO 6-inch o.c.within min.6-inch wide laps spaced 114- 5-339. Grade 33 steel or combination,min.1.5-inch attach FB Ultra Fasteners(concrete only)with Drill-Tec 2 3/8 in. inch o.c.and sealed with a 1.625-inch heat weld. -45.0 structrural concrete Barbed XHD Plates Min.22 ga.,type B, Drill-Tec XHD(steel only)or Drill-Tec#14 One or more layers,any Prelim. EverGuard TPO 6-inch o.c.within min.6-inch wide laps spaced 112.5- 5-340. Grade 33 steel or Fasteners(concrete only)with Drill-Tec 2 3/8 in. -60.0 structrural concrete combination,min.1.5-inch attach FB Ultra Barbed XHD Plates inch o.c.and sealed with a 1.625-inch heat weld. Min.22 ga.,type BV Min.200 psi,min.3-inch thick EverGuard TPO Drill-Tec XHD with Drill-Tec 2 in.Double Barbed Fastened through to engage steel deck,6-inch o.c. 5-341. (0.5%),Grade 33 steel Elastizell Lightweight N/A FB Ultra XHD Plates(to engage steel deck) within 6-inch wide laps spaced 114-inch o.c.and sealed -75.0 Insulating Concrete with a 1.5-inch heat weld. NEMO ETC,LLC Evaluation Report 01506.09.05-R30 for FL5293-R29 Certificate of Authorization#32455 6"Edition(2017)FBC NON-HVHZ EVALUATION Revision 30:06/15/2018 Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 51 of 99 EverGuard° TPO 60 mil Membrane Information Sheet Updated: 6/ 18 Quality You Can Trust...From North America's Largest Roofing Manufacturer!"' ® EVER GUAR® TPO / Jaw Why TPO • Great Value—Excellent performance at a MEMBRANE cost-effective price • Excellent Seam Strength—Heatwelded seams provide greater seam strength to taped.and other seams • long-term Weathering—Excellent long-term —� heat and UV resistance Fall River Courthouse,Fall River,mosoch j,_41 • Energy Saving—Highly reflective and emis- sive white roof can help reduce energy costs and urban heat island effect Installation • CREST Energy Savings Calculator—See your EverGuard®TPO 60 mil Membrane is suitable potential savings at cool.gaf.com for all types of single-ply systems: • Versatile Application Method • Mechanically Attached Application...for a Why GAF EverGuard® TPO quick and cost-effective system that can be Y installed practically year-round. • Outperforms standard TPO in heat aging • RhinoBond®Application...can be applied and UV tests—the best predictors of TPO performance without using adhesives and installed prac After accelerated heat aging at 275OF tically year round. Qualifies for the same (135'C)for 105 days, EverGuard®TPO guarantee length as an adhered system.* showed no cracking—while every one of the • Adhered Application...can be installed with competitors' samples had failed! See below: EverGuard® 1 121 Solvent-Based Adhesive, -UV testing—Greater than 2.5 times the EverGuard® Low VOC Adhesive, or Ever- industry standard (ASTM D6878 weather Guard®WB 181 Water-Based Adhesive for resistance test) the smoothest appearance. Provides excellent • Guarantees are available up to 25 years wind uplift performance. when using EverGuard®TPO 60 mil Membrane.* Accessories • Easier to install due to: Field fabrication of TPO accessories is time-con- Large welding window suming, costly, inconsistent, and can lead to Most complete line of accessories unreliable details that compromise a watertight -10' (3.05 m)wide sheets roofing system. EverGuard®TPO prefabricated accessories deliver consistent quality and elim- inate the worry and problems often associated with field fabrication. They can also boost pro- ductivity up to 200%,**while reducing installed cost by up to 12%- *See applicable guarantee for complete coverage and restrictions. EIE.G—.. '*Based on GAF estimate to field-fabricate Hashing details. Quality You Can TPO Competitor A i Trust...From - North America's Largest Roofing n California O Manufacturer!- ® fl Compl an SPt FM APPROVED U.S.only gat com e, 4i' site, '' TPO membranes meet the Competitor-B Competitor C it of ICC ER-6030performance requirements EverGuardO TPO 60 mil Membrane Applicable Standards UL Listed, FM Approved, Miami-Dade County Product Control Approved, State of Florida Approved, CRRC Rated, Title 24 Compliant% ENERGY STAR®Certified", ASTM D6878. Physical Properties ASTM Test Method ASTM D6878 Minimum EverGuard8 Typical Test Data 1.Certain data is provided in MD(machine direction)x CMD(cross machine direction)format. 2.Data is based upon typical product performance,and is subject to normal manufacturing tolerance and variance. Nominal Thickness ASTM D751 0.039'(min.)(0.99 mm) 0.060'11.52 mm) Breaking Strength ASTM D751 Grab Method 220 Ibf/in.(38.5 kn/m) 305 Ibf x 290 Ibf(454 x 432 kg/ml Factory Seam Strength ASTM D751 66 Ibf(98.34 kg/m) 135 Ibf(membrane failure)(201.1 kg/m) Elongation at Break ASTM D751 15% 30% Heat Aging ASTM D573 90%Retention of Breaking Strength 100% and Elongation at Break Tear Strength ASTM D751 8'x 8'(203 x 203 mml Sample 55 Ibf(81.95 kg/m) 75 Ibf x 130 Ibf(1 1 1.8 x 193.7 kg/m) Puncture Resistance FTM 101 C Method 2031 Not Established 380 Ib.(172 kg) Cold Brittleness ASTM D2137 -49C -40'C Permeance ASTM E96 Not Established 0.08 Perms Dimensional Change ASTM D1204 @158-F(70°C),6 hrs. +/-1% 0.4% Water Absorption ASTM D471 d 158-F(70'C), 1 week +/-3.0%(top coating only) 0.7% Hydrostatic Resistance ASTM D751 Method D Not Established 430 psi Ozone Resistance ASTM D 1 149 No visible deterioration @ 7 x No visible deterioration 0 7 x magnification magnification SRI(Solar Reflectance Index) N/A N/A 94/81 Initial/Aged 83 Aged Title 24 Reflectivity(white)Initial/Aged ASTM C 1549 N/A 0.76/0.68ASTM E903 N/A 81.9%Reflectance Emissivity(white)Initial/Aged ASTM C 1371 N/A 0.90/0.83 ASTM E403 N/A 0.94 Weather Resistance ASTM G 155//36878 10,080 Kj/(m2•nml at 340 nm >25,000 N/(m2 nm)at 340 nm Heat Aging ASTM D573 240T(1 15'Cl for 32 weeks 60 weeks Thickness Above Scrim ASTM D7635 Min 30%of Total Thickness 22.1 mil(Nominal) Guarantee Up to 25 years *White, Energy Gray, and Energy Tan Membranes Only **ENERGY STAR*only valid in the U.S. Product Data (1.52 x 30.5 ml (1.83 x 30.5 m) (2.44 x 30.5 m) (3.05 x 30.5 ml (3.65 x 30.5 m) (500 sq.ft.[46.5 sq.m]) (600 sq.ft.[55.74 sq.m]) (800 sq.ft.[74.3 sq.m]) (1,000 sq.ft.[92.9 sq.m]) (1,200 sq.ft.[111.484 sq.r 162 Ib.(73.5 kg) 194.4 Ib.(88.2 kg) 257 Ib.1117 kg) 322 Ib.(146.1 kg) 386.4 Ib.(175.3 kgl White,Tan, Gray Store rolls on their sides on pallets or shelving in a dry area. • Membrone rolls are heavy. Position and install by at least two people. Note:Membrane rolls shipped horizontally on pallets,stacked pyramid-style,and banded. Product sizes,dimensions, and widths ore nominal values and are subject to normal manufacturing/packaging tolerance and variation. RhinoBond'is a registered trademark of OMG. 1=9 Quality You Can Trust... From North America's gaf,com Largest Rooting Rlanu!acturer!" ©2018 GAF 6/18• a-42