Loading...
461 Atlantic Blvd COMM17-0016 OHM Description-GROUNDING ELECTRODE (NEUTRAL) BUS P1ANELBOARD KWH METER W10 SERVICE DISC. MEANS w 0 J EQUIPMENT GROUNDING BUS 5 6 AWG GROUNDING BUSBAR(S) 7 I 3/4" x 1OFT g Z(D�ZOTH CU CLAD GROUND RODS (TYPICAL) (3>7 WELD a SLAB/GRADE tzl tri 6 rr 1 II II MIN 20FT #3/0 BARE CU 11 I1 ENCASED IN BLDG - I I MIN 2"THICK FOOTING lil 20FT MIN I IN DIRECT i I- CONTACT WITH EARTH ---------------------- METALLIC UNDERGROUND WATER PIPE 4 SYSTEM GROUNDING DETAIL GROUNDING DETAIL NOTES: NO SCALE #O 1. EQUIPMENT GROUNDING CONDUCTOR (GND) -REFER TO POWER RISER FOR WIRE SIZE. 2. ALL SERVICE GROUNDING CONNECTIONS SHALL BE DONE WITH EXOTHERMIC WELDS. �25 N INSTALLED, GROUND RESISTANCE SHALL BE MEASURED, TO ASSURE THAT GROUND 43"' �VALU?EOFOHM MAXIMU RESISTANCE IS ACHIEVED. IF NOT, ADDITIONAL GROUNDING SHALL BE PROVIDED TO M T P CIF C L E. 4. GROUNDING ELECTRODE CONDUCTOR (NEUTRAL) REFER TO POWER RISER FOR WIRE SIZE. 5. MAIN BONDING JUMPER SIZE PER NEC 250-66. 6. #4 AWG GROUNDING ELECTRODE CONDUCTOR. 7. GROUNDING ELECTRODE CONDUCTOR PER NEC TABLE 250.66 cc LABEL PANEL: PHASE 'B' IS HIGH LEG LABEL PANEL: PHASE 'B' IS HIGH LEG rN PANEL- K :�_Oop DESIGN •- FEED SURF TOP MOUNTED 240/120V V, FEED" 22K AIC 3 PH, 4 W, VERTICAL 225 AMP, MAIN LUGS 2 -SECTION PANEL AWG KVA AMP CK SIZE LOAD SERVING AMP AWG SIZE KVA AMP LOAD CK PHASE CK A B C AMP KVA LOAD AWG SIZE SERVING ■m mmm® ■MMM mmmm ��m® =0 • REC- REACH -IN REF CK1 12 0.6 20 1 2 15 1.6 12 ELEC BOILER K3 **SHUNT TRIP DEVICE** 12 N/A 20 3 4 GROUNDING i 904.241.8010 REQUIREMENTS. FU59328 (PER REC- BRAISING PAN K5 12 0.6 20 5 6 - N/A 12 **SHUNT TRIP DEVICE** **SHUNT TRIP DEVICE** 12 N/A 20 7 8 AWG KVA AMP CKT SIZE LOAD PHASE CKT A B C AMP KVA AWG LOAD SIZE SPACE ONLY 7 **HIGH LEG -DO NOT USE'** 43 45 47 /~ 49 51 53 55 57 59 /-\ 61 63 65 67 69 71 73 75 77 79 ' 81 '� 83 /� 44 46 48 50 54 ^ 56 58 60 62 64 66 ^ 68 70 72 74 76 78 '� 80 82 ' ` 84 9 '� 10 12 12 12 12 12 12 12 12 12 12 12 12 12 **HIGH L G -DO NOT USE** UNLESS USED FOR COMPLIANCE WITH NEC. REC- HOLDING CAB K18 12 1.0 20 11 12 20 1.0 12 REC- HOLDING CAB K18 REC- HOLDING CAB K11 12 1.9 20 13 14 20 1.0 1 12 REC- HOLDING CAB K19 **SHUNT TRIP DEVICE" 12 N/A 20 15 16 **HIGH L G -DO NOT USE** REC- REACH -IN REF K16 12 0.9 20 17 18 20 1.0 12 REC- HOLDING CAB K20 GLYCOL PUMP K23 8 4.5 40 19 '� 20 20 1.0 12 REC- HOLDING CAB K20 21 22 **HIGH L G -DO NOT USE** SODA DISPENSER K26 12 0.5 20 23 24 20 1 1.0 12 REC- HOLDING CABK22 ICE MACHINE 10 14.3 30 125 1 26 20 1.0 12 1 REC- TEA DISP. K28 27 - 28 **HIGH L G -DO NOT USE** POS K36 K29 12 0.4 20 29 '� 30 20 0,7 12 REC- CARVING STATION K32 PREP TABLE K30 12 0.4 20 31 32 20 0.7 12 REC- CARVING STATION K33 **HIGH LEG -DO NOT USE" 33 34 20 1 2.7 12 THREE WELL HOT WELL K34 PREP TABLE 0 12 0.4 1 20 35 36 THREE WELL HOT WELL K31 12 2.7 20 37 � 38 20 0.6 12 FREEZER CABINET K37 39 40 30 5.5 10 ICE CREAM MACHINE REC- TEA DISP. K28 12 1.0 20 41 42 KVA LOAD- 39.7 (SECT 1: 37.OKVA + SECT 2: 20.1KVA = 57.7KVA CONNECTED/37.5 DEMAND) PANEL- K SURF -MQUNTED 240/120V V, TOP FEED, 22K AIC 3 PH, 4 W, VERTICAL 225 AMP, MAIN LUGS 2 -SECTION PANEL SERVING AWG SIZE KVA AMP LOAD CKT PHASE A B C CKT AMP KVA AWG LOAD SIZE SERVING UNDER CABINET REF K38 12 0.6 20 43 ^ 44 15 1.3 12 SAUSAGE PRESS K39 **HIGH LEG -DO NOT USE * 45 46 48 BENCH MIXER K41 12 0.7 20 47 MUG CHILLER 134 12 0.7 20 49 5020 0.7 12 BACK BAR COOLER B8 **HIGH LEG -DO NOT USE * 51 52 "HIGH EG -DO NOT USE** BLENDER STATION 815 12 0.6 20 53 54 20 0.4 12 POINT OF SALE B18 B 2 2,N 56 20 0.6 12 BACK BAR COOLER B25 BACK BAR COOLER B21 12 0.6 20 55 58 "HIGH EG -DO NOT USE** **HIGH LEG -DO NOT USE" 57 '­ � 60 20 1.0 12 COOLER LIGHTS/ASSOC CORD DROP 12 10.5 20 59 62 20 1.8 12 MARGARITA MACHINE B27 MUG CHILLER B9 12 1 0.7 20 61 64 **FIIGH EG -DO NOT USE** **HIGH LEG -DO NOT USE" 63 66 20 0.7 12 REC- GAS RANGE K8 REC- BAR FREEZER 12 0.7 20 65 68 20 INZA 12 **SHUNT TRIP DEVICE** REC- BAR GLASS WASHER 12 1.9 20 67 70 **FIIGH EG -DO NOT USE** *HIGH LEG -DO NOT USE** 69 72 20 1.0 12 REC- HOLDING CAB K19 REC- HOLDING CAB K22 12 1.0 20 1 71 74 20 1.0 1 12 AIR COMPRESSOR RECEPT- GEN/DINING 12 0.7 20 173 76 **FIIGH ` EG -D0 NOT USE** **HIGH LEG -DO NOT USE" 75 78 20 0.2 12 FACP RECEPT- DINING USB 12 1.4 20 77 ^ CIRC PUMP CP -1 12 0.2 20 79 80 20 0.7 12 RECEPT- OFFICE/FSC 82 ** IGH EG -DO NOT USE** **HIGH LEG -DO NO USE" 1 81 WATER SOFTENER 12 0.2 1 20 183 84 201 0.2 1 12 CIRC PUMP CP -2 KVA LOAD- 20.1 1 C C LABEL PANEL: PHASE 'B' IS HIGH LEG 3 3 4 1 1 2 1 j� 4#1 & 1 #6(G) 1 1/4"C. ROOF 6- PHOTOCELLQ Otq EXTERIOR MANAGES OFFICE �, / o LABEL EMERGENCY POWER OFF # O WIRE GUTTER ®CEILINGQ BREAK �- GLASS TYPE PUSH BUTTON LOCATE PER FIRE MARSHALL FIN CL 7 4 5 (4 -POLES) WP EO TC INTERIOR LIGHTS DP K P-1 UTILITY COMPANY UTILITY CO o o METER �' P � F P-7 TRANSFORMER -- w j w i' N 11 M N Q U j N LABEL „OUTSIDE PATIO LGT" t , 1 I 240/120 3PH 4W= I , li S it � 1 ST FLOOR II I CTs I� GRADE --- o I _p. I PROVIDE CONNECTION TO PYLON SIGN, VERIFY LOCATION P-21 PRIOR TO ROUGH -IN. PANEL- P :�_Oop DESIGN •- FEED 22K AIC TRIP) 800 ER MAIN BKR (W/SHUNT RAT] its SERVING AWG KVA AMP CK SIZE LOAD PHASE CK A B C AMP KVA AWG LOAD SIZE SERVING www.dcoop.com LGT- SITE 8 *HIGH LEG -DON T US---** LGT- 0/S PORCH 10 LGT- 0/S 12 **HIGH LEG -DO NOT USE.** LGT- BAR 12 REC-ROOF 12 **HIGH LEG -DON T USI:-'** DISHWASHER EFK-5 12 DISHWASHER HOOD (LGT) 12 **HIGH LEG -DO NOT USE_** PYLON SIGN 10 LGT- 0 S BLDG 10 EF -1 12 **SUNT -TRIP DEVICE** 12 EF -2 12 F� **SUNT -TRIP DEVICE** 12 1.5 1.5 1.5 0.7 0.4 0.5 0.1 1.5 1.5 3.6 - 2.5 - 20 20 20 20 20 20 20 20 20 20 15 20 15 J_ 20 1 3 5 7 9 ^ 11 ^ 13 15 17 19' '� 21 ^ 23- 25 27 29 31 33 35 37 39 41 0 01111-111 r, mg: ===► "HIGH LEG -bo N4 AHU/CU-1 (OUTHOUSE) (OUTHOUSE) Mr PROTECTIONSURGE t `► ,mU �■■ PANEL ■m mmm® ■MMM mmmm ��m® =0 • i■'® M®m rum • ! ® MIN no ■■®■■=■■m on on MM �: �■ UNSMESM, mmmmon m����r m■■m■■■®®i® ���� ®M"M' m�■mom' 10®M0 CIVIL ENGINEERING' 1 ICE MACHINE COND ei® ■ .. • v .. • ' ' P WIRE/BREAKER SIZES ARE FOR REFERENCE ONLY. PRIOR TO ROUGH -IN FIELD VERIFY EXACT EQUIPM 904-356-8520 SEE EL STRUCTURAL ENGINEERING ALEXANDER GRACE CONSULTING, INC. GROUNDING i 904.241.8010 REQUIREMENTS. FU59328 (PER Y7.7. KVA LOAD- 26.7 M 26.7KVA + SECT 2: 19.6KVA = I■ CONNECTED/32.2 DEM ND) PANEL- P LANDSCAPING SURF TOP MOUNTED 240/120V V, FEED 22K AIC 3 PH, 4 W, 125 AMP, MAIN LUG (VERTICAL 2 -SECTION) SEE 'ELEC SITE PLAN'. SERVING AWG KVA AMP CKT SIZE LOAD PHASE CKT A B C AMP KVA AWG LOAD SIZE SERVING LABEL PANEL: PHASE 'B' IS HIGH LEG 3 3 4 1 1 2 1 j� 4#1 & 1 #6(G) 1 1/4"C. ROOF 6- PHOTOCELLQ Otq EXTERIOR MANAGES OFFICE �, / o LABEL EMERGENCY POWER OFF # O WIRE GUTTER ®CEILINGQ BREAK �- GLASS TYPE PUSH BUTTON LOCATE PER FIRE MARSHALL FIN CL 7 4 5 (4 -POLES) WP EO TC INTERIOR LIGHTS DP K P-1 UTILITY COMPANY UTILITY CO o o METER �' P � F P-7 TRANSFORMER -- w j w i' N 11 M N Q U j N LABEL „OUTSIDE PATIO LGT" t , 1 I 240/120 3PH 4W= I , li S it � 1 ST FLOOR II I CTs I� GRADE --- o I _p. I PROVIDE CONNECTION TO PYLON SIGN, VERIFY LOCATION P-21 PRIOR TO ROUGH -IN. PANEL- P :�_Oop DESIGN SURF TOP MOUNTED 240/120V V, 3 PH, FEED 22K AIC (VERTICAL 4 W, 125 AMP, MAIN LUG 2 -SECTION) FEED THRU L S SERVING AWG KVA AMP CK SIZE LOAD PHASE CK A B C AMP KVA AWG LOAD SIZE SERVING www.dcoop.com LGT- SITE 8 *HIGH LEG -DON T US---** LGT- 0/S PORCH 10 LGT- 0/S 12 **HIGH LEG -DO NOT USE.** LGT- BAR 12 REC-ROOF 12 **HIGH LEG -DON T USI:-'** DISHWASHER EFK-5 12 DISHWASHER HOOD (LGT) 12 **HIGH LEG -DO NOT USE_** PYLON SIGN 10 LGT- 0 S BLDG 10 EF -1 12 **SUNT -TRIP DEVICE** 12 EF -2 12 F� **SUNT -TRIP DEVICE** 12 1.5 1.5 1.5 0.7 0.4 0.5 0.1 1.5 1.5 3.6 - 2.5 - 20 20 20 20 20 20 20 20 20 20 15 20 15 J_ 20 1 3 5 7 9 ^ 11 ^ 13 15 17 19' '� 21 ^ 23- 25 27 29 31 33 35 37 39 41 /� 2 4 6 8 10 12 14 16 18 '� 20 ^ 22 ^ 24 26 28 30 32 34 36 38 40 20 20 20 20 20 20 20 20 20 20 20 15 1.2 ** 0.2 0.2 ** 0.5 1.1 ** 1.6 0.4 ** 0.5 1.4 ** 0.9 0.9 "HIGH 2.5 12 IGH 12 12 IGH 12 12 IGH 12 12 IGH 12 12 IGH 12 12 12 12 LGT/REC OUTHOUSE LEG -DO NOT USE** LGT- DINING RM LEG -DO NOT USE** LGT- PATIO LGT- NORTH PATIO LEG -DO NOT USE** LGT- KITCHEN/RESTROOM RECEPT- BAR TV LEG -DO NOT USE** RECEPT- BAR TV RECEPT- BAR USB LEG -DO NOT USE** RECEPT- KITCHEN - SMOKER LEG -DO NOT USE** EF -3 **SUNT -TRIP DEVICE 461 Atlantic Blvd. Atlantic Beach, FI CIVIL ENGINEERING' 1 BAKER KLEIN ENGINEERING WIRE/BREAKER SIZES ARE FOR REFERENCE ONLY. PRIOR TO ROUGH -IN FIELD VERIFY EXACT EQUIPM 904-356-8520 SEE EL STRUCTURAL ENGINEERING ALEXANDER GRACE CONSULTING, INC. GROUNDING i 904.241.8010 REQUIREMENTS. FU59328 (PER M.E.P. ENGINEERING KVA LOAD- 26.7 (SECT 1: 26.7KVA + SECT 2: 19.6KVA = 46.3KVA CONNECTED/32.2 DEM ND) PANEL- P LANDSCAPING SURF TOP MOUNTED 240/120V V, FEED 22K AIC 3 PH, 4 W, 125 AMP, MAIN LUG (VERTICAL 2 -SECTION) SEE 'ELEC SITE PLAN'. SERVING AWG KVA AMP CKT SIZE LOAD PHASE CKT A B C AMP KVA AWG LOAD SIZE SERVING 7 GAS WATER HEATERS 12 **HIGH LEG -DO NOT US--** (2) FLY FANS 12 2 FLY FANS 12 **HIGH LEG -DON T US:--** 1/2HP LIFT STATION 12 GAS WATER HEATERS 12 **HIGH LEG -DO NOT USI---** VACUUM PACKING K40 12 BACK BAR COOLER B4 12 **HIGH LEG -DO NOT USI---** CORD DROP 12 KITCHEN HOOD (LGT) 12 **HIGH LEG -DO NOT US--** EVAP COIL 12 EVAP COIL 12 **HIGH LEG. -DO NOT US:--** REC- PROJECTORS 12 ROOF EXH FAN (EF1,3) 12 **HIGH LEG -DO NOT USI---** SPARE 0.2 1.1 1.1 1.1 0.2 0.5 0.7 0.5 0.4 1.0 1.0 1.0 1.8 20 20 20 20 20 20 20 20 20 20 20 20 20 20 43 45 47 /~ 49 51 53 55 57 59 /-\ 61 63 65 67 69 71 73 75 77 79 ' 81 '� 83 /� 44 46 48 50 54 ^ 56 58 60 62 64 66 ^ 68 70 72 74 76 78 '� 80 82 ' ` 84 20 20 20 20 20 20 20 20 20 20 20 20 20 20 0.2 "HIGH 0.4 0.4 "HIGH 1.8 1.6 "HIGH 0.9 0.4 "HIGH 0.2 0.7 "HIGH 0.8 0.4 "HIGH 0.7 0.5 "HIGH 12 12 12 12 12 12 12 12 12 12 12 12 12 TAMPER/FLOW EG -DO NOT USE** REC.- AV EQUIP EG -DO NOT USE** ICE MACHINE HEAT TRACE EG -D0 NOT USE** RECEPT- RESTROOMS - TBB EG -DO NOT USE** LGT- DINING RM LGT- SMOKER EG -DO NOT USE** LGT- SERVERY RECEPT- BAR TV EG -DO NOT USE** RECEPT- N. PATIO T RECEPT - N. PATIO TV EG -DO NOT USE** ISPARE 4. PROVIDE 4#4/0 & 1#4(G)-2 1/2"C. UNLESS USED FOR COMPLIANCE WITH NEC. 5. TIMESWITCH/PHOTOCELL. 4 -POLE (1P -CONTROLS CONTACTOR C1, 2P -CONTROLS PYLON SIGN, 6. FROM SPD CIRCUIT BREAKER TO SPD DEVICE- KEEP CONDUCTOR LENGTHS TO A MINIMUM. TV 7. EXTEND BRANCH CIRCUIT THRU CONTACTOR C2, (CONTROLLED BY TIME CLOCK POLE -3) CLEAR OF ANY OBSTRUCTIONS SUCH AS; ROOF TOP EQUIP/PARAPET WALLS ETC. CONNECT FOR A`%P'' OPERATION VIA TIMECLOCK,+�'"IAS r ®p'"®"°°•• ° �` POWELL & HINKLE ENGINEERING P.A. ROBERT L. HINKLE PE 29302 KVA LOAD- 19.6 (ADD TO SECT 1) Eh9 ° ,o ° � Vis- 1409 KINGSLEY AVENUE, BLDG 12A GALTON C. MOK PE 33192 7 I LSJ ; l I :�_Oop DESIGN DESIGN/COOPERATIVELLC 1032 HENDRICKS AVENUE JACKSONVILLE, FL 32207 7 TEL / (904) 290-1032 7 FAX / (904) 592-5892 www.dcoop.com (`-----------�� FUAA26001646 CLIENT #10 Rick Moyer LOCATION 461 Atlantic Blvd. Atlantic Beach, FI CIVIL ENGINEERING' 1 BAKER KLEIN ENGINEERING WIRE/BREAKER SIZES ARE FOR REFERENCE ONLY. PRIOR TO ROUGH -IN FIELD VERIFY EXACT EQUIPM 904-356-8520 SEE EL STRUCTURAL ENGINEERING ALEXANDER GRACE CONSULTING, INC. GROUNDING i 904.241.8010 REQUIREMENTS. FU59328 (PER M.E.P. ENGINEERING ®RISER NOTES: POWELL & HINKLE ENGINEERING, PA. 2 904.2645570 PNL/CKT ADDRESS PERMANENTLY LABELED AT FACP. EMERGENCY LTG CKTS ONLY SHALL HAVE #FUEB-4577 LANDSCAPING 1. TRENCH AND INSTALL CONDUITS/PULLWIRE/XFMER PAD/GROUND AS REQUIRED BY ELEC UTILITY CO, TBD INTERIOR DESIGN SEE 'ELEC SITE PLAN'. DESIGN COOPERATIVE LLC 7 7 2. PER ELEC UTILITY CO REQUIREMENTS PROVIDE FROM ELEC UTILITY CO XFMR Al VE REVISIONS 4-20-1F 7 0 ASI 3 10-04-1 f CONDUIT/CONDUCTORS/METER SOCKET/POST/SUPPORTS/METER ADDRESS LABEL. 0 ASI 6 11-02-1 E ��, ASI 8 11-09=1 E 3. PROVIDE 2 SETS: 4- #600 MCM, IN 4"C. T�j 8118290?� TED Op NO SCALE 4. PROVIDE 4#4/0 & 1#4(G)-2 1/2"C. UNLESS USED FOR COMPLIANCE WITH NEC. 6 RFI 6 - - � ASI#12 03-21-1 g 04-1 ASI#15 04-25-1� ASI 16 05-13-1 c ASI 17 06-10-1S PROJECT NO: 1611' POWER RISER, PNL SCHEDULES AND CALC . ° p & H ORANGE PARK, FLORIDA 32073 LANE R. HINKLE PE 48076 WIRE GUTTER TO BE MOUNTED ABOVE CEILING. ; ; �• .2i THOMAS M. ELDER PE 56121 8. 8-POLE.,30a.,120V LIGHTING CONTACTOR C2, CONTROLLED BY TIME CLOCK (POLE 3) (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA. REG. EB -4577 RICHARD A. MATHE S PE 59418 ��E06/10/�9�DAVID R. SPELL JR. PE 54729 E 302 46 j° • i ► P% `F°° � This item has been electronically signed and sealed b Thomas M. Elder PE using a Digital Signature. Printed copies of this document are not RM IT SET 1' Y 9 Y 9 9 9 P ��sr*o4°9°+ considered signed and sealed and the signature must be verified on any electronic copies. telder@powellandhinkle.com L �r 2019.06.10 11:15:50-04'00' (`-----------�� #10 ® _ PANEL SCHEDULES NOTES: UTILITY CO PRIMARY J 'ELEC SITE PLAN' - 1 --------------------------' � #3/0 GND 3 ----� MI GND � SYSTE DETAIL)1. WIRE/BREAKER SIZES ARE FOR REFERENCE ONLY. PRIOR TO ROUGH -IN FIELD VERIFY EXACT EQUIPM NT SEE EL (SEE SERVICE ENTRANCE" SELECTION AND PROVIDE WIRE AND BREAKER SIZE & TYPE TO MATCH MECHANICAL EQUIPMENT GROUNDING i REQUIREMENTS. (PER UTILITY CO) ®RISER NOTES: 2. FACP CIRCUIT SHALL HAVE LOCK -OUT TYPE CIRCUIT BREAKER MARKED RED, LABELED 'FACP CKT', PNL/CKT ADDRESS PERMANENTLY LABELED AT FACP. EMERGENCY LTG CKTS ONLY SHALL HAVE 1. TRENCH AND INSTALL CONDUITS/PULLWIRE/XFMER PAD/GROUND AS REQUIRED BY ELEC UTILITY CO, LOCK -OUT TYPE BREAKER, MARKED RED, & LABEL 'EMERG LTG CKT'. SEE 'ELEC SITE PLAN'. 3. EXTEND CIRCUIT THRU CONTACTOR C1. (CONTROLLED BT TIME CLOCK POLE -1) o 2. PER ELEC UTILITY CO REQUIREMENTS PROVIDE FROM ELEC UTILITY CO XFMR 4. EXTEND CIRCUIT THRU TIME CLOCK (POLE -2) /tr p W p RISER P O V V E I \ I \ I E I \ CONDUIT/CONDUCTORS/METER SOCKET/POST/SUPPORTS/METER ADDRESS LABEL. 5. HANDLE TIES SHALL BE USED FOR ALL BRANCH BREAKERS WHICH SHARE A NEUTRAL CONDUCTOR. ��, 3. PROVIDE 2 SETS: 4- #600 MCM, IN 4"C. MULTI -POLE BREAKERS SHALL BE PROVIDED FOR ALL 208 OR 480 LOADS HANDLE TIES NOT PERMI TED Op NO SCALE 4. PROVIDE 4#4/0 & 1#4(G)-2 1/2"C. UNLESS USED FOR COMPLIANCE WITH NEC. 5. TIMESWITCH/PHOTOCELL. 4 -POLE (1P -CONTROLS CONTACTOR C1, 2P -CONTROLS PYLON SIGN, 6. FROM SPD CIRCUIT BREAKER TO SPD DEVICE- KEEP CONDUCTOR LENGTHS TO A MINIMUM. 3P -CONTROLS CONTACTOR C2, 4P -SPARE) WITH PHOTOCELL MOUNTED ON THE ROOF FACING NORTH 7. EXTEND BRANCH CIRCUIT THRU CONTACTOR C2, (CONTROLLED BY TIME CLOCK POLE -3) CLEAR OF ANY OBSTRUCTIONS SUCH AS; ROOF TOP EQUIP/PARAPET WALLS ETC. CONNECT FOR A`%P'' OPERATION VIA TIMECLOCK,+�'"IAS r ®p'"®"°°•• ° �` POWELL & HINKLE ENGINEERING P.A. ROBERT L. HINKLE PE 29302 6. 6 -POLE, 30A.,120V LIGHTING CONTACTOR C1, CONTROLLED BY TIME CLOCK. (POLES 1 & 2) �� 7 COMBINE HOMERUNS IN WIRE GUTTER AND EXTEND WIRING TO PANEL IN 2 C QUANTITY AS REQUIRED Eh9 ° ,o ° � Vis- 1409 KINGSLEY AVENUE, BLDG 12A GALTON C. MOK PE 33192 6 RFI 6 - - � ASI#12 03-21-1 g 04-1 ASI#15 04-25-1� ASI 16 05-13-1 c ASI 17 06-10-1S PROJECT NO: 1611' POWER RISER, PNL SCHEDULES AND CALC . ° p & H ORANGE PARK, FLORIDA 32073 LANE R. HINKLE PE 48076 WIRE GUTTER TO BE MOUNTED ABOVE CEILING. ; ; �• .2i THOMAS M. ELDER PE 56121 8. 8-POLE.,30a.,120V LIGHTING CONTACTOR C2, CONTROLLED BY TIME CLOCK (POLE 3) (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA. REG. EB -4577 RICHARD A. MATHE S PE 59418 ��E06/10/�9�DAVID R. SPELL JR. PE 54729 E 302 46 j° • i ► P% `F°° � This item has been electronically signed and sealed b Thomas M. Elder PE using a Digital Signature. Printed copies of this document are not RM IT SET 1' Y 9 Y 9 9 9 P ��sr*o4°9°+ considered signed and sealed and the signature must be verified on any electronic copies. telder@powellandhinkle.com L �r 2019.06.10 11:15:50-04'00'