Loading...
1735 Maritime Oak Dr RES19-0044 Revision Revision Request/Correction to Comments **ALL INFORMATION rt �„ HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 n fill Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#:rVI"l Revision to Issued Permit OR ❑ Corrections to Comments Date: Project Address: I� 1 V \ ,r'I V C" 0 Contractor/Contact Name: �����6+ we �e�e �1 Contact Phone: "� ("�� �S Email: Description of Proposed Revision/Corrections: :5p r- 1fA I hB 1� affirm the revision/correction to comments is inclusive of the proposed changes. inted name) • ill proposed revision/corrections add additional square footage to original su mittal? No ❑ Yes (additional s.f.to be added: ) • ll proposed revision/corrections add additional increase in buildi/alue o original submittal? No ❑*Yes (additional increase in building v ) (contractor must sign if increase in valuation) *Signature of Contractor ent: (Office Use On y) LPApproved ❑ Denied ❑ Not Applicable to Department Permit Fee Due Revision/Plan Review Comments r� #G/ty - d 6 D ent Review Required: E I r E D Buildin Panning&Zoning Reviewed By Tree Administrator JUN 2 5 2019 Public Works -7 . p 2 Public Utilities ✓ _ZO` 7 Public Safety BUliding I*1ej)artf11ef1t Date Fire Services City of Atlantic Beach, FL Updated 10/17/18 ULSBERG ENGINEERING Residential and Commercial Structural Engineers June 20, 2019 Riverside Homes 12276 San Jose Blvd, Suite 120 Jacksonville, Florida 32223 Re: Lot 98 Atlantic Beach Country Club To Whom It May Concern: At the subject project, it is my understanding that the framer did not construct the rimboard/sheathing lap splices as indicated in our structural details. To account for this deficiency, additional fasteners will be required as described below: • The 2nd floor studs should be attached to the sole plate with Simpson SDWC15450 or 1/4" x4%" SDS screws at 32" o.c. • The 2nd floor sole plate should be attached to the floor trusses below with Simpson SDWC15450 or 1/4" x 4'/2" SDS screws at 24" o.c. • The floor trusses should be attached to the I" floor double plate with Simpson SDWC15600 or V4" x 6" SDS screws at 24" o.c. • The I" floor double plate should be attached to the studs with Simpson SDWC15600 or 1/4"x 6" SDS screws at 32"o.c. • The 1 S` floor studs should be attached to the sole plate with Simpson SDWC 15450 or '/4" x 4'/2" SDS screws at 32"o.c. Please note that the remaining details for hardware and sheathing installation as shown in our structural drawings will still apply. oS. S/M'��--- y a OFFICE COPY If you have any u 'an@�� `�' el free to contact my office. Sincere = No. 50791 * = REVISION STATE OF ;�Q,, BPA Sl q' d`Jyy Floyd S. Si on, $,�,�'•:c�OR 10 \��,;; DATE ? / 3 /p FL PE 50ANAL E '��`'1:` SIGNED �— 11481 Old St.Augustine Rd., Suite 202,Jacksonville,Florida 32258 Phone(904)886-2401,Fax(904)260-4367,FL CA No. 25846