1735 Maritime Oak Dr RES19-0044 Revision Revision Request/Correction to Comments **ALL INFORMATION
rt �„ HIGHLIGHTED IN
City of Atlantic Beach Building Department GRAY IS REQUIRED.
800 Seminole Rd, Atlantic Beach, FL 32233 n
fill Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#:rVI"l
Revision to Issued Permit OR ❑ Corrections to Comments Date:
Project Address: I� 1 V \ ,r'I V C"
0
Contractor/Contact Name: �����6+ we �e�e �1
Contact Phone: "� ("�� �S Email:
Description of Proposed Revision/Corrections:
:5p r- 1fA
I hB 1� affirm the revision/correction to comments is inclusive of the proposed changes.
inted name)
• ill proposed revision/corrections add additional square footage to original su mittal?
No ❑ Yes (additional s.f.to be added: )
• ll proposed revision/corrections add additional increase in buildi/alue o original submittal?
No ❑*Yes (additional increase in building v ) (contractor must sign if increase in valuation)
*Signature of Contractor ent:
(Office Use On y)
LPApproved ❑ Denied ❑ Not Applicable to Department Permit Fee Due
Revision/Plan Review Comments r� #G/ty - d 6
D ent Review Required: E I r E D
Buildin
Panning&Zoning Reviewed By
Tree Administrator JUN 2 5 2019
Public Works -7 . p
2
Public Utilities ✓ _ZO` 7
Public Safety BUliding I*1ej)artf11ef1t Date
Fire Services City of Atlantic Beach, FL Updated 10/17/18
ULSBERG
ENGINEERING
Residential and Commercial Structural Engineers
June 20, 2019
Riverside Homes
12276 San Jose Blvd, Suite 120
Jacksonville, Florida 32223
Re: Lot 98 Atlantic Beach Country Club
To Whom It May Concern:
At the subject project, it is my understanding that the framer did not construct the
rimboard/sheathing lap splices as indicated in our structural details. To account for this
deficiency, additional fasteners will be required as described below:
• The 2nd floor studs should be attached to the sole plate with Simpson SDWC15450 or 1/4"
x4%" SDS screws at 32" o.c.
• The 2nd floor sole plate should be attached to the floor trusses below with Simpson
SDWC15450 or 1/4" x 4'/2" SDS screws at 24" o.c.
• The floor trusses should be attached to the I" floor double plate with Simpson
SDWC15600 or V4" x 6" SDS screws at 24" o.c.
• The I" floor double plate should be attached to the studs with Simpson SDWC15600 or
1/4"x 6" SDS screws at 32"o.c.
• The 1 S` floor studs should be attached to the sole plate with Simpson SDWC 15450 or '/4"
x 4'/2" SDS screws at 32"o.c.
Please note that the remaining details for hardware and sheathing installation as shown in our
structural drawings will still apply.
oS. S/M'��---
y a OFFICE COPY
If you have any u 'an@�� `�' el free to contact my office.
Sincere = No. 50791
* = REVISION
STATE OF ;�Q,, BPA Sl q' d`Jyy
Floyd S. Si on,
$,�,�'•:c�OR 10 \��,;; DATE ? / 3 /p
FL PE 50ANAL E '��`'1:` SIGNED �—
11481 Old St.Augustine Rd., Suite 202,Jacksonville,Florida 32258