950 Sailfish Dr POOL19-0024 pool permitSWIMMING POOL DRAWINGS FOR The Rebidas Residence :Site Address -- 950 Sailfish Drive West -- -- Atlantic Beach, FL 32233 -- OFFICE COPY Sheet List 1 C-1.0 Cover Sheet 2 C-1.1 Site Plan 3 C-1.2 General Pool Plan 4 C-1.3 Pool Layout 5 C-1.4 Plumbing Details OFFICE COPY 4-H fl/ Z O N Impervious Calculations Existing Lot: 7,464 SF Existing structures 3,226 SF Proposed work 134 SF C Existing impervious 43.2% � Proposed impervious 2.7% N New impervious 44.8% N Mem Existing structures include house, v LL .; driveway, walways, and AC pads o A9 0 -Proposed work includes pool structure m 0 r fi. Qj3 ,i +4 0 e qV _o � U tT IT U x M1 ^ Z_ m O CL a * ' ► A� p Cl) O LL scnLE. i„ = Zo, +" ys DRAWN BY: NWE �} A" ! * 3 DESIGNED BY: HO CHECKED BY: BH + U z U. c This drawing is not an official survey and is a N utilized for new pool, spa, and deck location. This drawing is based on the official survey provided W by All American Surveyors of Florida, Inc. Dnna zoig vi Sheet No: q C-1.1 w Z J X LU IL O x a BARRIER COMPLIANCE • DOORS AND WINDOWS LEADING TO POOL AREA WILL BE ALARMED • PERIMETER FENCE I—..—.. _.. _..—..—.. _.. _.. _.. _.. _.. _.. _.. _.. _.. _.. _.. _.. _.. _.. _.. _..— DQPIDGDTV 1 IAIG Pool Size: Pool Area: Pool Perimeter: Pool Coping: Deck Area: 13 Ft. x 25 Ft. 222 Sq. Ft. 76 Ft. 82 Ft. NA Sq. Ft. w Z J H w w IL O M IL N O ro Z Xro _ r-? m CD w N N p N Q N y LL x ro F Q t 0 J O X O LL J C' 4b SCALE: 3/16" =1' DRAWN BY: NWE DESIGNED BY: HO CHECKED BY: BH w Date: Ma 2019 Sheet No: C-1.2 OFFICE COPY Deck material (TBD) 811 Pool Beam Thickness Pavers shown _ 0 Typical Pool Coping POOL BEAM DESIGNED AT 8" w T (2) # 3 con t. Compactedbond beam 26' a° Paver Base v # 3 Rebar @ 12" oc 1z' -s 6' o° a' -s" each way continuous in pool shell 8-6,. Compacted � N M Fill - -� — — — 7 , — — — cn -7 co m 6" ))))))))) ; LL F�� Min. Pool Wall c�^�� -;IQj Concrete Thickness " -� vim �- t . Pool Shell L O Ln Q 1'-6" • 4I Min. Pool Floor 12" Wide �� ° L_. M I m a Thickness Step 3 -•I v + 'y� z IF L9 a f Squaring =co Ir Dimension 00 I. N � O >11 POOL WALL/FLOOR SECTION �.' — ` — `— o _ II O N N O > co C O O O J O Back of beam in ..� o `� Water line with Patio a' -o° m Q Top of Beam level Sun Q Pool Shelf Existing +' � ry J Deck Covered ' _ "� `- '; :: =..'J E � p Concrete X OO J =)LL s 11'-2" 15'-2" io u Angle of repose (45 degrees) SCALE: 1/4"=1' Water level DRAWN BY: NWE Pool EXISTING COVERED DESIGNED BY: HO ' CHECKED BY: BH 6"Raised beam Top of Beam with waterfall Deck CONCRETE PATIO U `O z Z3 IF r Q v thick q pool floor O 10'-6" RESIDENCE Date: V-6"9'611 May 2019 POOL PROFILES Sheet No: - Q C-1.3 3/16" = 1' 7,642 gallons @ 42 gpm 3.03 hour turnover Max Velocity for system in Recirculation Mc > 2" main drain suction @ 42 gpm = 4.2 ft/s > 2" skimmer suction line @ 42 gpm = 4.2 f > 2" return lines @ 70 gpm = 4.3 ft/s > 1.5" return lines @ 70 gpm = 7.6 ft/s > 2" waterfall line @ 36 gpm = 3.7 ft/s Pressure side of system will not exceed 8 ft/s as designed Suction side of system will not exceed 6 ft/s as designed Line shown are schematic only, run plumbing as needed based on field conditions at the line sizes shown r — — --t _ — — I i I I �= i I t' Tandy Variable Speed 14P i.. CS Cartridge Filter Voltage i maxwells P pe size ' Cae#on Weight § Overall Lengtn'A' i VSPHP270 G 1125 25 2 7 233 0 VAC (_ 2 250V0 1✓ 3' I „ 5 lbs. �� m 30 3,8 Performance Curves CS Cartridge Filter 200 Sq. Ft, CS250 VSpHp 70 Series Pump Performance Curves ..250 Sq. Ft. CURVE "H, .. CURVE A'" ,n Eat/Entrance 100 Ex Filter(HF)mm 3 psib.A3 feet 90 Degree Fitng 1C0RVE C" Heater(HE) psi O feet A5 Degree Filling 418! 45 3 7e -. 3hSt1 R;3AA .. 30 Branch Tee 0.75 Tb Suction Head (Hs) Enter anumber of fittsnr9s Flow Pipe site Length K Inc C -V 9-V Ex 90 45 Tr Tb V bP 42 2.0 7fl 3.4(3 1 1 25 w� � x 3J RPR+? 20 r 20 „ r '730 RPM r `. 10 1000 "I'm b, 0 20 — - 60 80 1051 12iI w„ . Flaw Nate, Gallons Per Minute (CPM) 42 gpm @ 17' TDH, approx. 1,730 RPM 2” Return Line – – – - 2" Skimmer —� 2" Main Drain – – – – – 2" Waterfall 1.5" Vent Line POOL EQUIPMENT RESIDENCE LOCATION CS 200 Jandy Filter CS100 CS Cartridge Filter 100 Sq. Ft. CS450 CS Cartridge Filter 150 Sq. Ft. CS200 CS Cartridge Filter 200 Sq. Ft, CS250 CS Cartridge Filter ..250 Sq. Ft. CS Filter Head Loss Curves �fae� Hwa tau Pfi neaa! OFFICE COPY — szso @ 42 gpm, 1 psi pressure drop across clean filter, use 3 psi for dirty filter Pool Recirculation P Total DMMic Head Calculations .Amors T K Aber `ow z 42 fpm IncreaserDecreaser 0.30 Inc Check Valve 2.60 C -V Elevation Plead (ME) F 2 feet Butterfly Valve 0.35 -V Eat/Entrance 100 Ex Filter(HF)mm 3 psib.A3 feet 90 Degree Fitng 4 25 90 Heater(HE) psi O feet A5 Degree Filling 418! 45 Run Tee 0.301 Tr Branch Tee 0.75 Tb Suction Head (Hs) Enter anumber of fittsnr9s Flow Pipe site Length K Inc C -V 9-V Ex 90 45 Tr Tb TOT 42 2.0 7fl 3.4(3 1 i l t 51 77 i 42 I6 Ft Discharge (HP) Enter a number of fittkngs Flow Pipe size Leriath K Inc C -V B -V Ex QO 45 Tr Tb TOT TDH HE Suis F3 2S3_ Design Point 42 i17 h Jandy VS @ 1730 RPM {V 'HP27fi) v U C v N ro I m in n N N N rq to ?� rn aj j LL aj m i w u }+ O L N C O O ro ON1 Q —°o, a v z E N -1 O O N � r; z_DO0 It N N N O — N O_ > M O O O J d) N y LL X LnCz Y U N Q i X O 1 J d SCALE: No Scale DRAWN BY: N W E DESIGNED BY: HO CHECKED BY: BH W � Q Date: Ma 2019 Sheer No: C-1.4 g /�-.yra rsn 6 w 0g f H i� W o z hick, I �2 f 4' liilli ��a liiili 90 1 9 mom o �i ZT.Qd� P a to wa: Z a 4 cn n (06 1) WOW f!' ® �e (sit, `s �tn waa C, � N $ q f �MeQnf .o t �d8 �+'(1-01) [ r. 0%a `» �wy� 0 C Zao o �C . p (t • b N w 0 Ln V6 C) f l !r f r0 ° oa}� tr aeotfjN� Z w ®� U f f (bot CQt� '` < ' C3 _ Q go W It, C) r 4 fl1 s�z sg�°t ��� 3 � � 8 t UJI W h(n >G 4 f qr 3�, �- ?yaw x$ 210 WC76 '90f dot by�'$r �x N ti u z ., O ,� f /1 �� fes'' a �¢ y V f j 0 o, °�soo �, a° r /�,,� rte" 0 a Ac C/i T( n .off a0 f $p a ZLa °� Nz�ten° f ,� cn �, F8 ��- .¢ f 1 •fit o m A �w w i ley QD Q °€`fit ash 7�8, z% 3 4 LA zo- w �5; 0 WOSOIL a Ir m Cl .Qgt VIS a �e Cia � En < (n 0= ca o w8u b +'� z Q 3:51 !1C fat // a COCy S W- MW lw3 t -Y� mat � D v ~gg w � F� ad r z$ g� N CL SEE wog r,s�°6 a 9y S� W O O c`°v z es9 w_ a m o (yy d W c^qyrann e- s®®s aoe421si u 1 Its I O(A 0 Pr Go °i iia 3 o z rs i d qd-j ^ _tA� T a��r:::NN �® tia aaaaa�mx�.z'ai' 4%} o Q tat m m a Li O cs Nwz p O {`ag®mgeo! i w m C 00Z<806 -,W�JZ ZZ EL�3 out = Sib '� �gs��gq�yy 9g� mixoZZI Qua w 3 m aeIaeea■aaeaaea It a e■ ¢a u 'SO id4�s300oa w a1uas_tiQ fin aus„axcse y^< wz Xm w—03MC'. Cd JOB SPECIFIC PIPE SIZING, TOTAL DYNAMIC HEAD CALCULATIONS AND EQUIPMENT SPECIFICATIONS AND DOCUMENTATION ARE TO BE PROVIDED BY THE POOL CONTRACTOR FOR EACH PROJECT. T14E POOL CONTRACTOR MUST USE THE MAXIMUM FLOW CAPACITY OF THE SELECTED PUMP AND PROVIDE HYDRAULIC CALCULATIONS FOR TDP TO DETERMINE PROPER PUMP AND PIPING SIZING. TPE MANUFAGTUR>rER'5 EQUIPMENT SPECIFICATIONS AND OTPER DOCUMENTATION FOR PUMPS, FILTERS, HEATER EQUIFI"fENT Ai�D MAIN DRAINS AND COVERS ARE TO BE SUBMITTED FOR REVIEW AND DOCUMENTATION FOR SIZING TWE CIRCULATION SYSTEM. 2-03 BARS - CONT. IN 8"X8" BOND BEAM POOL SWELL 3000 PSI PUMP MIX CONCRETE PNEUMATICALLY APPLIED. S" -l" IN VERTICAL WALLS (TTP) 6'-B" IN COVES AND FLOORS (TTP) 2500 MIN. GUNITE MAY BE SU55ITlUTED FOR 3000 P51 CONCRETE RETURN LINE RETURN INLET RECIRCULATION PUMP f UNDERWATER LIGHT J z / Itt CL c: - SKIMMER SUCTION 4 ryLu j3 J in - Lu z CHLORINATOR MAIN DRAINS MEET THE VIRGINIA GRAEME �Q u o `' 'q Ed MAIN DRAIN CTIO BAKER POOL AND SPA SAFETY ACT. :t $ Ci 0 � s POOL ). FILTER W. h F— f RETURN INLET LL `L /.®O._E 111 i5 m F°"" LU RETURN LINE Lu (, Lu (41 > Lu TYPICAL SWIMMING POOL w LC LOW PROFILE VARIES JUNCTION 4.0' SWIM BOX MIN. OUT 6"X6"03 BARS GRADE 40,12" O.C. 4" THICK CONCRETE DECK VERTICAL ANDW/ FIBER MIX 2500 PSI �y rCERAMIC TILE HORIZONTAL (TTP) ( 4" / i UL APPROVED? UNDERWATER LIGHT THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1.5 TIMES THE DIA. OF THE MAIN DRAIN PIPE. 1-1/2 TILS THE DIA, I-1/2 TIMES THE MAINi DRAIN DRAIN COMPACTED SOIL UNDER WATER_INE O I CONCRETE DECK 1/2" QUARTZ FINISH -' — / 4 = ao f MAIN DRAIN W/ RELIEF PLUG OR 2 �aofgo` HYDROSTATIC RELIEF VALVE, IF REQ'D. DEEP END FL00R AN ROCKBEO WALL REINFORCEMENT TO SLOPE BREAK- OSBAR 12" ION CENTER, EACH WAY( l.0' DEEP 03 BAR: G" ON CENTER, EACH WAY > l.O' DEEP AND OVER, SECTION a3 BARS 12" ON CENTER EACH WAY (GRADE 40) POOL SHELL 3000 PSI PUMP MIX CONCRETE PNEUMATICALLY APPLIED. 5"-1" INVERTICAL WALLS (TYP) 1 COVES AND FLOORS (TYPI 2500 IN. GUNITE MAY BE SUSSITIUTED FOR 3p00 PSI CONCRETE i GENERAL NOTES: I. POOL 15 TO BE BUILT TO COMPLY WITH FLORIDA, COUNTY AND CITY BUILDING CODES. 2, ALL METAL PARTS WITHIN 5 FT. WILL BE GROUNDED AS PER NATIONAL ELECTRIC CODE AND AS REQUIRED BY LOCAL INSPECTOR. 3. FILTRATION SYSTEM WILL HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER OF POOL WATER IN (12) TWELVE HOURS OR LESS. 4, POOL CONSTRUCTION TO BE THE SAME REGARDLESS OF SIZE AND SHAPE. IF FILL IS REQUIRED FOR 2 FT. TO 4 FT. OF WALL WEIGHT THEN WALLS WAVE TO BE REINFORCED WITW ADDITIONAL STEEL (8" 0.0, BOTH WAYS) AND/ OR EXTRA WALL THICKNESS (8" TO 10") S. ALL PVC PIPE WILL BE SCHEDULE 40. G. ALL METAL FIXTURES AND POOL LIGHTS TO BE BONDED TO POOL STEEL AND GROUND WIRE, 1. POOL ALARMS DO NOT NEED TO BE HARDWIRED S. SOIL CONDITIONS AT POOL LOCATION ARE ASSUMED TO BE ADEQUATE FOR A SINGLE FAMILY DWELLING. q. - TERMITE `CONTROL WILL BE APP1JED UNDER ALL POOL DEC -K5. id, ALL PUMPS AND FILTER$�WILL ;BE.>ANCHORED TO A CONCRETE PAD WITH TAP CON ANCHORS, 11, ALL POOL AND SPA SUCTION INLETS SHALL BR PROVIDED WITH A COVER THAT HAS BEEN TESTED AND ACCEPTED BY A RECOGNIZED TESTING FACILITY AND COMPLY WITH A.NZ.11AS.M.E. A112.19, SM, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS, AND WHIRLPOOLS BATHTUB APPLIANCES" 12. THE POOL DESIGN WILL MEET CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION, IS. RESIDENTIAL POOLS MUST COMPLY WITH CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION. 14, POOL CONSTRUCTION WILL MEET 2014 NATIONAL ELECTRIC CODE. SEE 680.26 (15)(2)(b) FOR PERIMETER BONDING USING AT LEAST ONER) 08 AWG BARE SOLID COPPER CONDUCTOR. I5. FOR RESIDENTIAL POOLS UP TO A WATER DEPTW OF 8'-O" 03 REBAR 12" O,O.B,W. OVER 8'-O'; SPECIAL ENGINEERING IS RECUIRED AND 15 NOT A PART OF THIS DRAWING SPECIFICATIONS. WALL THICKNESS SHALL PROVIDE CODE COVER OVER REINFORCING. FOR OVER 8'-0" A SPECIAL DESIGN WILL BE REQUIRED, 16. RESIDENTIAL POOLS SHALL COMPLY WITH THE ANSI/APSP/IGC-5 2011 FOR RESIDENTIAL INGROUND POOLS, ANSI/APSP/I00-3 2014 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS, AND AN51/AP5P/ICC-1 2013 FOR SUCTION ENTRAPMENT AVOIDANCE STANDARDS. AND ANSI/APSP/I00-15A 2013 STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY 1-1. DO NOT USE OR OPERATE POOL OR SPA IF THE SUCTION FITTING IS MISSING, BROKEN, OR LOOSE. 18. IF THE SUCTION INLET SYSTEM, SUCH AS AN AUTOMATIC CLEANING SYSTEM, IS A VACUUM CLEANER SYSTEM WHICH WAS A SINGLE SUCTION INLET, OR MULTIPLE SUCTIONS INLETS WHICW CAN BE ISOLATED BY VALVES, THEN EACH SUCTION INLET SHALL PROTECT AGAINST USER ENTRAPMENT BY EITHER AN APPROVED ANTI -VORTEX COVER, 12" X 12" GRATE OR LARGER, OR OTHER APPROVED MEANS., PARR MYNOWENBERG 4 ASSOC, INC. PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 11201 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32118 (386) 611-68011 FAX (386) 611-2114 TYPICAL RE51 DENTAL 5W/1=00L DE i ISN FOR FLORIDA LUXURY fi 0 01-5, INC. 14 LEVY ROAD ATLANTIC BEACH, FL. 32233 104-226-1526 / 0104-222-1188 GPC1458111 SWEET I OF 4 WATER LINE DECK OVER POUR ^i—= -I--- BRICK C GOP 1-03 BAR CONT. 6" OF WATER IN 5" THICK LINE TILES BEAM ALTERNATE BEAM FINISH DETAIL RETURN INLET RECIRCULATION PUMP f UNDERWATER LIGHT J z / Itt CL c: - SKIMMER SUCTION 4 ryLu j3 J in - Lu z CHLORINATOR MAIN DRAINS MEET THE VIRGINIA GRAEME �Q u o `' 'q Ed MAIN DRAIN CTIO BAKER POOL AND SPA SAFETY ACT. :t $ Ci 0 � s POOL ). FILTER W. h F— f RETURN INLET LL `L /.®O._E 111 i5 m F°"" LU RETURN LINE Lu (, Lu (41 > Lu TYPICAL SWIMMING POOL w LC LOW PROFILE VARIES JUNCTION 4.0' SWIM BOX MIN. OUT 6"X6"03 BARS GRADE 40,12" O.C. 4" THICK CONCRETE DECK VERTICAL ANDW/ FIBER MIX 2500 PSI �y rCERAMIC TILE HORIZONTAL (TTP) ( 4" / i UL APPROVED? UNDERWATER LIGHT THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1.5 TIMES THE DIA. OF THE MAIN DRAIN PIPE. 1-1/2 TILS THE DIA, I-1/2 TIMES THE MAINi DRAIN DRAIN COMPACTED SOIL UNDER WATER_INE O I CONCRETE DECK 1/2" QUARTZ FINISH -' — / 4 = ao f MAIN DRAIN W/ RELIEF PLUG OR 2 �aofgo` HYDROSTATIC RELIEF VALVE, IF REQ'D. DEEP END FL00R AN ROCKBEO WALL REINFORCEMENT TO SLOPE BREAK- OSBAR 12" ION CENTER, EACH WAY( l.0' DEEP 03 BAR: G" ON CENTER, EACH WAY > l.O' DEEP AND OVER, SECTION a3 BARS 12" ON CENTER EACH WAY (GRADE 40) POOL SHELL 3000 PSI PUMP MIX CONCRETE PNEUMATICALLY APPLIED. 5"-1" INVERTICAL WALLS (TYP) 1 COVES AND FLOORS (TYPI 2500 IN. GUNITE MAY BE SUSSITIUTED FOR 3p00 PSI CONCRETE i GENERAL NOTES: I. POOL 15 TO BE BUILT TO COMPLY WITH FLORIDA, COUNTY AND CITY BUILDING CODES. 2, ALL METAL PARTS WITHIN 5 FT. WILL BE GROUNDED AS PER NATIONAL ELECTRIC CODE AND AS REQUIRED BY LOCAL INSPECTOR. 3. FILTRATION SYSTEM WILL HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER OF POOL WATER IN (12) TWELVE HOURS OR LESS. 4, POOL CONSTRUCTION TO BE THE SAME REGARDLESS OF SIZE AND SHAPE. IF FILL IS REQUIRED FOR 2 FT. TO 4 FT. OF WALL WEIGHT THEN WALLS WAVE TO BE REINFORCED WITW ADDITIONAL STEEL (8" 0.0, BOTH WAYS) AND/ OR EXTRA WALL THICKNESS (8" TO 10") S. ALL PVC PIPE WILL BE SCHEDULE 40. G. ALL METAL FIXTURES AND POOL LIGHTS TO BE BONDED TO POOL STEEL AND GROUND WIRE, 1. POOL ALARMS DO NOT NEED TO BE HARDWIRED S. SOIL CONDITIONS AT POOL LOCATION ARE ASSUMED TO BE ADEQUATE FOR A SINGLE FAMILY DWELLING. q. - TERMITE `CONTROL WILL BE APP1JED UNDER ALL POOL DEC -K5. id, ALL PUMPS AND FILTER$�WILL ;BE.>ANCHORED TO A CONCRETE PAD WITH TAP CON ANCHORS, 11, ALL POOL AND SPA SUCTION INLETS SHALL BR PROVIDED WITH A COVER THAT HAS BEEN TESTED AND ACCEPTED BY A RECOGNIZED TESTING FACILITY AND COMPLY WITH A.NZ.11AS.M.E. A112.19, SM, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS, AND WHIRLPOOLS BATHTUB APPLIANCES" 12. THE POOL DESIGN WILL MEET CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION, IS. RESIDENTIAL POOLS MUST COMPLY WITH CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION. 14, POOL CONSTRUCTION WILL MEET 2014 NATIONAL ELECTRIC CODE. SEE 680.26 (15)(2)(b) FOR PERIMETER BONDING USING AT LEAST ONER) 08 AWG BARE SOLID COPPER CONDUCTOR. I5. FOR RESIDENTIAL POOLS UP TO A WATER DEPTW OF 8'-O" 03 REBAR 12" O,O.B,W. OVER 8'-O'; SPECIAL ENGINEERING IS RECUIRED AND 15 NOT A PART OF THIS DRAWING SPECIFICATIONS. WALL THICKNESS SHALL PROVIDE CODE COVER OVER REINFORCING. FOR OVER 8'-0" A SPECIAL DESIGN WILL BE REQUIRED, 16. RESIDENTIAL POOLS SHALL COMPLY WITH THE ANSI/APSP/IGC-5 2011 FOR RESIDENTIAL INGROUND POOLS, ANSI/APSP/I00-3 2014 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS, AND AN51/AP5P/ICC-1 2013 FOR SUCTION ENTRAPMENT AVOIDANCE STANDARDS. AND ANSI/APSP/I00-15A 2013 STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY 1-1. DO NOT USE OR OPERATE POOL OR SPA IF THE SUCTION FITTING IS MISSING, BROKEN, OR LOOSE. 18. IF THE SUCTION INLET SYSTEM, SUCH AS AN AUTOMATIC CLEANING SYSTEM, IS A VACUUM CLEANER SYSTEM WHICH WAS A SINGLE SUCTION INLET, OR MULTIPLE SUCTIONS INLETS WHICW CAN BE ISOLATED BY VALVES, THEN EACH SUCTION INLET SHALL PROTECT AGAINST USER ENTRAPMENT BY EITHER AN APPROVED ANTI -VORTEX COVER, 12" X 12" GRATE OR LARGER, OR OTHER APPROVED MEANS., PARR MYNOWENBERG 4 ASSOC, INC. PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 11201 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32118 (386) 611-68011 FAX (386) 611-2114 TYPICAL RE51 DENTAL 5W/1=00L DE i ISN FOR FLORIDA LUXURY fi 0 01-5, INC. 14 LEVY ROAD ATLANTIC BEACH, FL. 32233 104-226-1526 / 0104-222-1188 GPC1458111 SWEET I OF 4 RECIRCULATION CHLORINATOR POOL FILTER - MAIN DRAIN RETURN LINE TYPICAL 5PA POOL SHELL 3000 PSI CONCRETE PNEUMATICALLY APPLIED. G" IN VERTICAL WALLS (TYP) 6" IN COVES AND FLOORS (TYP) 2500 MIN. GUNITE MAY BE SU551TlUTED FOR 5000 P51 CONCRETE 1/2" QUARTZ FINISH UL APPROVED UNDERWATER LIGHT THERAPY JET RETURN LINE MAIN DRAINS MEET THE VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT. (SECOND MAIN DRAIN MAY BE ON SIDE WALL) DN) mz UNDERWATER LIGHT 73/4" BULLNOSE TILE OPTIONAL ON EDGE OF STEP. _ — 2 MAIN DRA I N5 ON FLOOR } 4" THICK CONCRETE DECK W/ FIBERMIX 9000 PSI WATER LINE 6"X6" CERAMIC TILE LOW VARIES PROFILE JUNCTION I BOX 1 � i - COMPACTED 501L 1 Q UNDER OONGETE L....... H DECK fn MAIN DRAIN LI —_ SUCTION LINE (I MAIN DRAIN W/ RELIEF PLUG OR 2" HYDROSTATIC RELIEF VALVE, IF REQ -D. SECTI � Ji EXTRA 03 BARS CONTINUOUS 03 BARS 12" O.G. opgpo VERTICAL AND 0-000 HORIZONTAL (TYPJ (GRADE 40) ROCKBED THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTIG F C COPY TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1.5 TIMES THE DIA. OF THE MAIN DRAIN PIPE. 1-1/2 TIMES THE DIA. 1-1/2 TIMES THE DIA. MAIN MAIN DRAIN DRAIN CAP TILE/ BRICK/ OR CANTILEVER WITH WATERLINE TILE F AGRLYIG FINISH 2-03 REBAR CONTINUOUS STEEL REINFORCED CONCRETE - 6 DECK AND TILE DETAIL PARKER MYNC14EN15ERG 4 A5500., INC. PROFESSIONAL ENGINEERS LAND50APE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32118 (386) 611-6891 FAX (586) 611-2114 TYPICAL RE -5I DENTAL SW/POOL Dr-51ON FOR FLORIDA LUXURY POOLS, INC. 14 LEVY ROAD ATLANTIC BEACH, FL. 32233 904-226-1326 / 904-222-1188 OFC14581199 SHEET 2 OF 4 POOL. BONDING NOTES: I. EQUIPOTENTIAL BONDING OF PERIMETER SURFACES REQUIRES ,4 8. COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE POOL AND SPA REBAR AS SHOWN, 4 LOCATIONS, MINIMUM AT EACH 5EFARATE BODY OF WATER, USING A #8 AWG COPPER CONDUCTOR; MINIMUM 08 AWG BARE FACED COPPER CONDUCTOR WHICH FOLLOWS THE CONTOUR OF THE PERIMETERBARE SOLER COPPER CONDUCTOR. FOR NON-CONDUCTIVE POOL SHELLS, BONDING SU THE POOL AND WHICH IS SECURED WITHIN OR UNDER THE AT 4 POINTS $WALL NOT BE REQUIRED SURFACE OF THE POOL FROM IS" TO 24" FROM THE INSIDE WALLS PERIMETER SURFACE 4" H 1 S BELOW S (THIN O E. THE PERIMETER q. COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE EQUIPMENT GROUND OF BONDING SHALL BE ATTACHED TO THE POOL REINFORCING SHELL THE POOL PUMP MOTOR AND OTHER ELECTRICAL COMPONENTS AS REQUIRED BY AT A MINIMUM OF 4 POINTS UNIFORMLY SPACED AROUND THE NEC 68026 (VERIFY LOCATIONS) USING MB AWG BARE SOLID COPPER WIRE. PERIMETER OF THE POOL. 10. COPPER BONDING CONDUCTOR SHALL BE BONDED TO ALL METALLIC COMPONENTS OF 2. ALL UNDERGROUND OR UNDER SLAB CONNECTIONS SHALL BE BY LISTED MEANS THE POOL AND SPA AND THE METAL STRUCTURES, INCLUDING, BUT NOT LIMITED TO, ALL PER NEC 250.8. BONDING CABLES UNDER SLAB SHALL BE PLACED AT THE BOTTOM HANDRAILS, DIVING BOARDS, AND LADDER. GRABRAILS IN THE POOL AND SPA AND OF EXCAVATION. AND INCLUDE ALL METAL WIRING AND ALIS FIXED METAL PARTS THAT ARE WITHIN 5 FT. HORIZONTALLY OF THE IN51DE WALL OF THE POOL (5PA) AND 12 FT VERTICALLY ABOVE 3. WHEN REBAR 15 UTILIZED FOR THE CONSTRUCTION OF PLANTERS AND FOOTERS THE MAXIMUM WATER LEVEL OF THE POOL USING #8 AWG BARE COPPER WIRE. ADJACENT TO THE POOL (WITHIN 5 FT), THIS REBAR SWALL BE BONDED U51NG p. ALL POOL AND SPA LIGHTING NICHES SHALL BE BONDED TO POOL AND SPA REBAR 08 AWG BARE SOLID COPPER CONDUCTOR BY LISTED MEANS PER NEC 2508 PER NEC 680. THE COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE TO THE BONDING CONDUCTOR. REBAR AT BOTH THE POOL AND THE SPA, PER NOTE 8, ABOVE, WHICH SHALL, IN 4. LOCATION OF COPPER BONDING CONDUCTOR, BONDING JUMPERS, AND CONNECTIONS TURN, PROVIDE BONDING OF THE LUMINAIRE NICHES. 5WOWN ARE DIAGRAMMATIC ONLY. CONTRACTOR $HALL FIELD ROUTE TO DETERMINE A) PER THE NEC, NFPA 10 ARTICLE 680.23 (6)(5), STATES THAT BONDING SHALL NOT BE EXACT LOCATION. BONDING CONDUCTOR SHALL CONFORM TO THE SHAPE OF THE POOL REQUIRED FOR LUMINAIRES THAT ARE LISTED FOR TWE APPLICATION AND HAVE NO NON - WHILE MAINTAINING SMOOTH RADIAL CURVES - NO q0° RADIUS SHALL BE PERMITTED. CURRENT CARRYING METAL PARTS. IN ADDITION, PER ARTICLE 680.26 (15)(4), EXCEPTION S. RE515TANCE OF THE GROUND SYSTEM SHALL NOT EXCEED 25 OHMS, STATES THAT LISTED LOW -VOLTAGE LIGHTING SYSTEMS WITH NON-METALLIC FORMING SWELLS G. IF REQUIRED, ALL GROUND RODS SHALL BE B/8" COPPER CLAD STEEL, V LONG SHALL NOT REQUIRE BONDING. AND DRIVEN TO A DEPTH OF 28" BELOW FINISHED GRADE, MINIMUM, AND WHERE THEREFORE, LUMINAIRES THAT ARE LOCATED IN THE QUIRE 2 CIRCUIT WITH PD/15ON E USED SHALL BE BONDED USING #8 AWG BARE SOLID COPPER CONDUCTOR BY LISTED NON-CURRENT CARRYING METAL PARTS ARE NOT REQUIRED TO BE GROUNDED/BONDED. MEANS PER NEC 2508 TO THE BONDING CONDUCTOR. 12, ELECTRICAL CONTRACTOR SHALL CALL FOR THE INSPECTION OF THE BONDING OF 1. SPECIAL CASES MAY INCLUDE, BUT ARE NOT LIMITED TO, VANISHING EDGE POOLS, THE POOL AND ITS PERIMETER SURFACES PRIOR TO COVER-UP OF THESE AREAS. POOLS WITH PERIMETERS OF VARYING (VERTICAL) GRADES, DIMIN15WED PERIMETER SURFACES LIKE EDGE PLANTERS, 5TOP/RETAINING WALLS, AND ZERO -LOT LINES, IN THESE CASES, THE BONDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH NEC 680.26, NOTE i (ABOVE), AND DIRECTION FROM THE AUTHORITY HAVING NOTE I JURISDICTION (AWJ). THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF THE BONDING WITH THE AWJ IN THE DETERMINATION OF ITS APPLICATION OF THE NEC. NOTES 2 AND 3 SPA I t BOND JUMPER NOTE 3 NOTE 8 TYPICAL TYPICAL BOND JUMPER NOTE q TYPICAL BOND JUMPER NOTE 10 TYPICAL 0 SWIMMINGPOOL LT FIXTURE NOTES i, 4, NOTE 11 LADDER, HANDRAIL, 0 � TYPICAL 5 AND 8 DIVING BOARD, ETC. /TRANSFORMER PUMP MOTOR JUNCTION BOX !IF USED) TYPICAL PO ,, L 15ONDING PLAN NOT TO 50ALE POOL LIGHT NICHE METAL CONDUITS BONb I NG L�G�ND OR PIPING SYSTEM • BO D CONNECTION, PER NEC 2508 CONTROL PANEL(5) o PARALLEL TAP CONNECTION, PER NEC 250.8 POOL UNDERGROUND BONDING CONDUCTOR, #S AWG (MINII-un REINFORCING STEEL s('1e G 1I Q "G d HEATER CASE TYPICAL POOL E30NDING '._;CHE IATIG g NOT TO SCALE SCHEMATIC NOTES: 1. TWE EQUIPOTENTIAL BONDING OF ALL CONDUCTIVE POOL SWELLS, PERIMETER SURFACES, METALLIC COMPONENTS, UNDERWATER LIGHTING, METAL FITTINGS, ELECTRICAL EQUIPMENT, AND METAL WIREWAYS/CONDUITS SHALL BE IN ACCORDANCE WITH NEC 68026. OR, AS , ACCEPTED BY THE AUTHORITY WAVING JURISDICTION (AWJ). PARKER FROM POOL OR APPARATUS BONDING CONDUCTOR OFFICE COPY NOTE 1 NOTE I MINIMUM 5/8" DIAMETER COPPER GROUND ROD FROM POOL REBAR OR DRIVEN UNTIL MAXIMUM BONDING CONDUCTOR RESISTANCE VALUE OF 25 OWM5 15 REACHED (IF USED) NOTE I TYPICAL E30ND I NG TYPES NOT TO SCALE NOTES: 1. SPLICES (WELDED OR MECHANICAL) SHALL BE PERFORMED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, PARKER MYNOWENBEkG 4 ASSOG., INC. PROFE551ONAL ENGINEERS LANDSCAPE ARCHITECTS 11201 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32118 (386) 611-68g1 FAX (386) 611-2114 TYPICAL RES I DENTAL 5WPOOL DESIGN FOR FLORIDA LUXURY POOLS, INC. -I4 LEVY ROAD ATLANTIC BEACI-I, FL. 32233 0104-226-1526 1 q04-222-1188 OPC1458ggq SWEET 3 OF 4 4" DECK (1) #5 REBAR CONT. MAX. TURN DOWN FOOTER DETAIL T 5LOPE/N0 FOOTING 'E I NT. i MOTMATE SLOPE FOOTING TYPE 2 SLAB—FOOTING DETAILS 2500 MIN. GUNITE MAY BE SUBSITIUTED FOR 5000 PSI CONCRETE USE 6X6 10/10 WWM OR FIBER MESH CURE FOR ONE WEEK BEFORE INSTALLING ANCHORS. I 1 3000 PSI CONCRETE W/ 2-05 RIBBON FOOTING 5) #5 REBAR CONT. IFTIN6Abs OR STEEPER' STEEP SLOPE FOOTING TYPE 2 PAVER DECK THE POOL CONTRACTOR SHALL PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6" ON CENTER IN BOTH DIRECTIONS IN AREAS WHERE THE ANGLE OF REPOSE IN ENCROACHED ON OR THE POOL SHELL ENCROACHES INTO THE I TO I AREA. EXISTING STRUCTURE 2" X 4" STRINGERS PLACED AT 2 FT ON CENTER IN ALL AREAS 3'-6" LESS FFIC STRINGER TO BE SUPPORTED BY CLEATING TO SUITABLE ANCHOR DEVICE SUCH AS A 2" X 4" ATTACHED WITH ANCHOR NAILS OR TAPGONS TO EXISTING CONCRETE LANAI OR EXISTING STRUCTURE OR ITS FOUNDATION. STEEL TEX FORM W/ ` EXISTING STRUCTURE STRUCTURAL STEEL �- I I IN PLACE TO BE - INDEPENDENTLY SUPPORTED �_I AWAY FROM SHORING. THE POOL SHELL WALL SHALL BECONSTRUCTED �— - — — THICKNESS PAVER DECK L���-OR OBU # 3 KEBABS ATA6" ON CENTER D IN' —Irlrn�il- EQUIVALENT BOTH WAYS IN AREAS THAT EXTEND I =_L(, MATERIAL TO RESTRAIN 51DE INTO THE ANGLE OF REPOSE= — OF EXCAVATION 'BACKFILL BEHIND SHORING TO PREVENT UNDERMINING OF STRINGER MAY BE DRIVEN EXISTING STRUCTURE. INTO GROUND MIN, 9" PROVIDE WEEP HOLES AS OR OTHERWISE SUPPORTED APPROPRIATE, TO PREVENT FROM KICKING OUT AT BASE. CONTRACTOR SHOULD ATTEMPT T4 CONSTRUCT ROUGH SHELL AS RAPIDLY AS CONDITIONS WILL ALLOW. THERE 15 NO 5U55TITUTE FOR RAPIDLY BACKFILLING EXCAVATION TO PREVENT SNORING DE'T'AIL UNDERMINING OF ADJACENT IN LOCATIONS WHERE EXISTING FOUNDATION IS STRUCTURE. THREATENED BY UNDERMINING DUE TO ADVERSE CONDITIONS AT THE TIME OF EXCAVATION SHORING MAY BE REQUIRED. PARKER MYNCNENBERG 4 ASSOC., INC. PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 52111 (386) 611-6891 FAX (386) 611-2114 TYPICAL RISIDENTAL 5W/POOL DESIGN FOR `rLORIDA LUXUIRY POOLS, INC. -14 LEVY ROAD ATLANTIC BEACH, FL. 32233 q04-226-1526 / q04-222-1188 45 11 SHEET 4 OF 4 Jandy Variable Speed Model No, tip I vonage s max Watis 1 Pipe Size Carton weight - ---- - ---------- Performance Curves ----------- ---- — �7— A 77 XLine shown are schematic only, run plumbing as needed based on field conditions at the line sizes shown r 2" Return Line 2" Skimmer 2" Main Drain 2" Waterfall 1.5" Vent Line Elevotion Head feet 3ry 6 9 Stjt ian Head (Hs) Pipc Lt a' 4 S 1 Z.C,i 70 6 EXISTING COVERED 30.00 CONCRETE PATIO 15.#9Q 30 4,( 2,8z,3 21,'� 20 (155 0 556 20 I or- -7 1 0,168 + 2.01 - -.1-1— -1--1 15 ' ----- '0 1 l - J r46 17-44 4 1 ------ 451 TDH Calculation program based on D. •. formula with a Hazen -Williams roughness coefficient of 130 A REVIEWED FOR CODE COt"V1PLIA,""_ CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS REVIEWED BY: OP',T 6-17-, a) U CU V) LL 5 cc to C) (V V) C 0 C) Ln M < 0 1 0 Z E c\j 0 ' C) 3 - aj Z (D t O 0o 0 a) c\l CIJ p• > CO N0 rn LL to CZ U) co 0 0 >< 0 __j Z:) 0 - LL C SCALE: No Scale DRAWN BY: N W E DESIGNED BY: HO CHECKED BY: BH )ate: June 2019 Sheet No: C-1.4 P S Total Head In Feet Conversion Chart Inches Mercury (Vacuum Gauge) NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH. GAGES TO BE INSTALLED AT THE TIME OF FINAL INSPECTION FOR VERIFICATION. 0 2 4 6 8 10 12 14 16 18 0 0 2.3 4.5 6.8 9 11.3 13.6 15.8 18.1 20.3 1 2.3 4.6 5.8 9.1 11.4 13.6 15.9 18.1 20.4 22.7 2 4.6 6.9 6.1 11.4 13.7 15.9 18.2 20.4 22.7 25 3 6:9 9.2 11.5 13.7 16 18.2 20.5 22.8 25 27.3 4 9:2 1 11.5 13.8 16 18.3 20.5 22.8 25.1 27.3 29.6 5 11.5 13.8 16.1 18.3 20.6 22.8 25.1 27.4 29.6 31.9 6 13.9 16.1 18:4 20.6 22.9 25.2 27.4 29.7 31.9 34.2 7 16.2 18.4 20.7 23 25.2 27.5 1 29.7 32 34.3 36.5 8 18.5 20.7 23 25.3 27.5 29.8 32 34.4 36.6 38.8 9 20.8 23.1 25.3 27.6 29.8 32.1 34.3 36.6 38.9 41.1 10 23.1 25.4 27.6 29.9 32.1 34.4 36.7 38.9 41.2 43.4 11 25,4 27.7 29.9 32.2 34.5 36.7 39 41.2 43.5 45.8 12 27.7 30 32:2 34.5 36.8 39 41.3 43.5 45 ;8 48.1 13 30 32.3 34.5 36.8 39.1 41.3 43.6 45.9 48.1 50.4 14 32.3 34.6 36.9 39.1 41.4 43.6 45.9 48.2 50.4 52.7 15 34.6 36.9 39.2 41.4 43.7 45.9 48.2 50.5 52.7 55 16 37 39.2 41.5 43.7 46 48.3 50.5 52.8 55 57.3 17 39.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 59.6 18 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 19 43.9 46.2 48.4 50.7 52.9 55.2 57.4 59.7 62 64.2 20 46.2 48.5 50.7 53 55.2 57.5 59.8 62 64.3 66.5 21 48.5 50.8 53 55.3 57.6 59.8 62.1 64.3 66.6 58.9 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 68.9 71.2 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69 71.2 73.5 24 55.4 57.7 60 62.5 64.5 66.7 69 71.3 73.5 75.8 25 57.8 60 62.3 64.5 66.8 69.1 71.3 73.6 75.8 78 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 27 62.4 64.6 66.9 69.2 71.4 73.7 75.9 78.2 90.5 82.7 28 164.7 66.9 69.2 71.5 73.7 1 76 78.2 80.5 82.8 85 29 67 69.3 71.5 73.8 76 78.3 80.5 82.8 85.1 87.3 30 69.3 71.6 173.8 76.1 78.3 80.6 82.9 85.1 1 87.4 89.6 31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92 32 73.9 76.2 78.4 80.7 83.1 85.2 87.5 89.7 92 94.3 33 76.2 78.5 80.7 83 85.3 1 87.5 89.8 92 94.3 96.6 34 78.5 80.8 83.1 85.3 87.6 89.8 92.1 94.4 96.6 98.9 35 80.9 83.1 85.4 87.6 89.9 92.2 94.4 96.7 1 98.9 101.2 NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH. GAGES TO BE INSTALLED AT THE TIME OF FINAL INSPECTION FOR VERIFICATION. Jandy Variable Speed 230 VAC i 2,250W i 2'l: - 3" Performance Curves 50 lbs VSPHP270 Series Pump Performance Curves 100 CURVE S' CURVE "A" t 90 4(i CURVE "C" 3. 70 i i 60 ar 50 2750 RPM 21 E 40 $ r 0 3620 730 RPM - � 0 RPM 0 20 40 60 BO 100 120 140 Flow Rate, Gallons Per Minute (GPM) 44 gpm Ca 18' TDH, approx. 1,730 RPM ---------------- Line --------------- Line shown are schematic only, run I k: plumbing as needed based on field conditions at the line sizes shown I k I I 2" Return Line — — — — — 2" Skimmer 2" Main Drain — — — — — 2" Waterfall 1.5" Vent Line CS 200 Jandy Filter CS100 CS Cartridge Filter 100 Sq. Ft, C3150 CS Cartridge Filter .. 150 Sq, Ft CS200 CS Cartridge Filter 200 Sq. Ft. CS250 CS Cartridge Filter. 250 Sq. Ft. C3 Filter Head loss Curves Deefw t tow rr haw) ModN No. `im00 esise iv cs2s0 03200 ... . Ptlter Area i i06 fid . 1.flt Z00 R' 250 IF Design Flow Rate I gpr.* as gine- .625W ft�5:WMaximum Flow 1 100wn I125 gpm 125 qpm gpmsix (6) Hour ._36 000 45.000 gal- 45 000 00 gal-. Capadty 1 gd0an$ :lone gallons I-$ Eight t8) Hour 48,000 64000 gal- 60.000 7 60.006 gal - capacity ga0ors Ions gaiters i bns Normal Start Up 6.15psi BISPsi & 15 psi i 6.15 psi Pressure Max. working Pres50 os ! 50 Psi 50 psi I. 50 PsiF —4— Gartrldgea � 1 1 1 —. I r Required ShiPpin9 Weight 284bs 1 261hs. 341bs i 36 Its, Height (W) 32%6' 1 32V 1 L 421,° !. 42'a' D aD sD. m rzo — CSt Se Flow RMa(apmt @ 44 gpm, 1 psi pressure drop across "x clean filter, use 3 psi for dirty filter 8,120 gallons @ 44 gpm 3 hour turnover Pressure side of system will not exceed 8 ft/s as designed Suction side of system will not exceed 6 ft/s as designed Pool Reeiroulation Pum�gr Totu1 Dxnomic Head Calculations M=nO Floor= 44;9pra tnemaseriDecre `I Elevation Head (1� v2 feet eutterflyValve EA/Entrance 11 Filter(Hp) 3�psi - Z693feet 90 Degree Fitting Heater(HF} nlpsifeet d.5 Degree Fitting Run Tee Branch Tee Suction Head (Hs) Erer o number of fittings Flow Pipe size Length K Inc C -V 8-V Ex 90 45 Tr Tb TOT 44 20 10-7T TFt 2.rmIf - fllh pf'3d "1a"..`T:5 1i; t ,4. , le.:flf) The -, 1,1 t 3' r.a 3a #1ts ? t xr* 11 ,t'S Srt'cfet:, `p T t iC Head(TDH) Ca ulation Worksheet t tmmer t.. "_o so ft of Stiff aeem of .Ott^ xte is * *gar IS1i r tO "Ou ', 'tilt 55£.r rnfni," I9ned .as 6 p' a I I , P,, -.'C 1 0 r y ssc )Via1f, fir*"" ft.tzr I'Dit &Sy.'tern HOW R'Ite 11, ;:ai"rEEi rnubot appruveil ff3Ire, I i0W, r..ail 4 C3isch ge(Fft} Enter onumber offittings Flew Pipe size Length i< Inc G -V B -V Ex 90 45 Tr Th TOT 44 30 4DO 1 1 1 1 7.704 COVERED COVERE2.0 ---_— -- _ 29.33 2.0 , 20 0.55 t _ 1 0.53 CONCRETE PATIO 14.67 2.0 20 _ 1,00 1 1 0.161 ff 14.67 2.fl 15 1,80 t i 2 0.3.52 ._._ ,. 20 1,00 bH - He - Has < Wo -1 w 17.09 Stan t 556 m1 —. _.. benign point = 44 sa'' RESIDENCE \__TDH Calculation program POOL EQUIPMENT based on Darcy -Weisbach LOCATION formula with a Hazen -Williams roughness coefficient of 130 REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS N U to a) I M N un U N m M �U- L U M L an 41 41 m U S._ N c OLo o 6 _O � Q O a Z (4 s U � U X Z m O f!) N Q M N to LL X U) Q J O X O J LJ._ J SCALE: No Scale DRAWN BY: NWE DESIGNED BY: HO CHECKED BY: BH REVIEWED BY: DATE: 6-/ /, /� Date: June 2019 OFFICE COii _ Sheet Not .T Total Head In Feet Conversion Chart ft cur (Vacuum Gauge) OFFICE COPY Inches er J 0 2 4 6 8 10 12 14 16 18 0 0 2.3 4.5 6.8 9 11.3 13.6 15.8 18.1 20.3 1 2.3 4.6 5.8 9.1 11.4 13.5 15.9 18.1 20.4 22.7 2 4.6 6.9 6.1 11.4 13.7 15.9 182 20.4 22.7 25 3 6.9 9.2 11.5 13.7 16 18.2 20.5 22.8 25 27.3 4 9.2 11.5 13.8 16 18.3 20.5 22.8 25.1 27.3 29.6 5 11.5 13.8 16.1 18.3 20.6 22.8 25.1 27.4 29.6 31.9 6 13.9 16.1 18:4 20.6 22.9 25.2 27.4 29.7 31.9 34.2 7 16.2 18.4 20.7 23 25.2 27.5 29.7 32 34.3 36.5 8 18.5 20.7 23 25.3 27.5 29.8 32 34.4 36.6 38.8 9 20.8 23.1 25.3 27.6 29.8 32.1 34.3 36.6 38.9 41.1 10 23.1 25.4 27.6 29.9 32.1 34.4 36.7 38.9 41.2 43.4 P 11 25.4 27.7 29.9 32.2 34.5 36.7 39 41.2 43.5 45.8 S 12 27.7 30 322 34.5 36.8 39 41.3 43.5 45 ;8 48.1 I 13 30 32.3 34.5 36.8 39.1 41.3 43.6 45.9 48.1 50.4 14 32.3 34.6 36.9 39.1 41.4 43.6 45.9 48.2 50.4 52.7 15 34.6 36.9 39.2 41.4 43.7 45.9 48.2 50.5 52.7 55 16 37 39.2 41.5 43.7 46 48.3 50.5 52.8 55 57.3 17 39.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 59.6 18 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 19 43.9 46.2 48.4 50.7 52.9 55.2 57.4 59.7 62' 64.2 20 46.2 48.5 50.7 53 55.2 57.5 59.8 62 64.3 66.5 21 48.5 50.8 53 55.3 57.6 59.8 62.1 64.3 66.6 58.9 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 68.9 71.2 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69 71.2 73.5 24 55.4 57.7 60 62.5 64.5 66.7 69 71.3 73.5 75.8 25 57.8 60 62.3 64.5 66.8 69.1 71.3 73.6 75.8 78 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 27 62.4 64.6 66.9 69.2 71.4 73.7 75.9 78.2 90.5 82.7 28 64.7 66.9 69.2 71.5 73.7 76 78.2 80.5 82.8 85 29 67 68.3 71.5 73.8 76 78.3 80.5 82.8 85.1 87.3 30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1 87.4 89.6 31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92 32 73.9 76.2 78.4 80.7 83.1 85.2 87.5 89.7 92 94.3 33 76.2 78.5 80.7 83 85.3 87.5 89.8 92 94.3 96.6 34 78.5 80.8 83.1 85.3 87.6 89.8 92.1 94.4 96.6 98.9 35 80.9 83.1 85.4 87.6 89.9 92.2 94.4 96.7 98.9 101.2 *NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH. ** GAGES TO BE INSTALLED AT THE TIME OF FINAL INSPECTION FOR VERIFICATION.