Loading...
501 Cruiser Ln RERF19-0093 ShingleDESIGN SPECIFICATIONS DESIGN CODE: 2017 FLORIDA BUILDING CODE — RESIDENTIAL DESIGN LOADS: ACTUAL AND UNIFORM ROOF ROOF LOADING (cd=1.25) TOP CHORD LIVE LOAD 20 psf TOP CHORD DEAD LOAD 7 psf (ARCH SHINGLES) BOTTOM CHORD LIVE LOAD 10 psf BOTTOM CHORD DEAD LOAD 5 psf DEFLECTION CRITERIA: ROOF FRAMING: LIVE LOAD L/240 TOTAL LOAD L/180 WIND LOADING: ASCE 7/10 BASIC WIND SPEED (ASCE 7-10) — — — — — - — 130 MPH ROOF PITCH — — — — — — — — — — —— EXISTING EXPOSURE CATEGORY — — — — — — — — — — — B SCOPE OF SERVICE MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE FOR ANY OF THEM TO CONSTRUCT THE WORK INACCORDANCEWITH THE CONTRACT DOCUMENTS. LIMITS OF STRUCTURAL ENGINEERING DESIGN RESPONSIBILITIES: THE ITEMS SPECIFICALLY DESIGNED BY THE STRUCTURAL ENGINEER ARE LIMITED TO THE TRUSS REPAIR SHOWN ON THIS SHEET. INFORMATION SHOWN ON THESE DRAWINGS REGARDING EXISTING CONDITIONS HAVE BEEN OBTAINED BASED ON AVAILABLE SOURCES AT THE TIME OF DESIGN INCLUDING ASSUMPTIONS BASED ON EXPERIENCE WITH SIMILAR STRUCTJRES. THE ACTUAL AS—BUILT CONDITION FOUND IN THE FIELD MAY VARY FROM INFORMATION INDICATED IN THESE DRAWINGS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY ENGINEER IN WRITING BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN THESE DRAWINGS AND/OR ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL REPAIR/REPLACE ANY DAMAGED EXISTING STRUCTURAL MEMBERS DISCOVERED DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING CONSTRUCTION. SAFETY OF THE STRUCTURE AND PERSONNEL DURING CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. PICTURE OF DAMAGED ROOF TRUSS ABOVE BEDROOM SCALE: 1/2" = F-0" REVIE'"IED FOR CODE CON11PLIANCE CITY OF ATLANTIC EE CH SF4 PERMITS FOR ADDITIONAL' REQUIREMIENTS AND CONDITIONS _uis A Pontigo PE REVIEWED BY; DATE: -Z.,?_/� JAN 31 2018 FL PE NO 53311 C.J J u�i'O Ln O .._. o Ln W ry ^ m aj Q x c: wLL- 00Itil .-.n vvi v CEJ O 00 M '�ovztt Lam N Q` .. O x N U O OFFICE COPY Q IL ce W D o z U O Lf N i Q Lr) c LI I00 Q Q 0 7 00 -7 M E" Q Q C~_7 "H 0 w 0 5 p z co w Q C.J J u�i'O Ln O .._. o Ln W ry ^ m aj Q x c: wLL- 00Itil .-.n vvi v CEJ O 00 M '�ovztt Lam N Q` .. O x N U O OFFICE COPY Q