Loading...
384 Aquatic Dr RES19-0215 Windows/Siding PERMIT NUMBER RESIDENTIAL PERMIT RES19-0215 CITY OF ATLANTIC BEACH ISSUED: 7/15/2019 800 SEMINOLE ROAD ATLANTIC BEACH. FL 32233 EXPIRES: 1/11/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 384 AQUATIC DR RESIDENTIAL ALTERATION WINDOWS AND SIDING $2000.00 RESIDENTIAL TYPE OF REALESTATE BUILDING USE ZONING: SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: "'m 1718185128 AQUATIC GARDENS COMPANY: ADDRESS: CITY: STATE: ZIP: F B ANDREWS 6245 OGDEN ROAD JACKSONVILLE FL 32216 CONTRACTING LLC OWNER: ADDRESS: CITY: STATE: ZIP: LARSON DIANE L S140 ORTEGA BLVD JACKSONVILLE FL 32210-8306 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $32.S01 STATE DBPR SURCHARGE 4S5-0000-208-0700 0 $4.09 STATE DCA SURCHARGE 4S5-0000-208-0600 0 $2.73 WORK WITHOUT PERMIT 455-0000-322-1000 0 $17S.00 Issued Date: 7/15/2019 1 of 2 r City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road R E_S 1 Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904)247-5845 9' E-mail: building-dept@coab.us L Date routed: City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: SPA Ar:w1ccito- ment r view required Yes -No Bu Applicant: Planning &Zoning Tree Administrator C� Public Works Project: Public Utilities Public Safety Fire Services Review fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Kp*,P-r o v e d. [:]Denied. [:]Not applicable (Circle one.) Comments: (!5 3D �l PLANNING &ZONING Reviewed by: Date:—7 4 TREE ADMIN. Second Review: FlApproved as revised. FDeniec V E]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ElApproved as revised. ElDenied. F]Not applicable Comments: Reviewed by: Date: Revised 05/1912017 QFFIG� Wr, U,Iated 10191111 Building Permit Application City of Atlantic Beach Building Department "ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED. 0 3,D,'�,3,3 Job Address:--2214 A2two—+r C- br I, I Permit Number: R Legal Description �—)x A; b i4 A A RE#/-7/ /9'- 5,/c-;Ir Valuation of Work(Replacement Cost)$ Z-4 Heated/Cooled SF Non-Heated/Cooled • ClassofWork: E]New ElAddition OAlteration'kRepair ElMove DDemo E]Pool XWindow/Door • Use of existing/proposed structure(s): ElCommercial Xpesidential • If an existing structure,is a fire sprinkler system installed?: EIYes 'XNo • Will tree(s)be removed in association with proposed promect? E]Yes(must submit separate Tree Removal Permit) 'S?No Describe in detail the type of work to be performed: '7 ek-c--f- F Florida Product Approval# for multiple products use product approval form PropertV Owner Information Name ,DI 'I on ne Lou-,c) Address ctevtzoorj Avv.s city ryl U'l I I,?_ State t� Zip Phon- qo( — e E-Mail rl / CL r.,) U xi CILD M, n e r v oL. ry-),,cl C' n rn ry-i. c,p Owner or Agent(If Agent, Power;f Attorney or Agency Letter Required) Contractor Information I N a m e o f C c,m p a n y lifying Agent Vwz.> Address City J,,:iir-)6 State Zip %41 Office Phone cl�4 - JobSiteCCrtJt tNum6er State Certification/AegiAratign T,&', (-1A4Ujk2, E-Mail r- FIN- Architect Name& Phone# Lul As. Engineer's Name&Phone# W Workers Compensation Insurer OR Exempt Expiration Date Application is hereby made to obtain a permit to do the work and installations as ir Pd. I certify that no work or installa SZ 0 commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regullEnfij — construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIG05 LU 00 WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirementQfoi%3 (3 a permit,there may be additional restrictions applicable to this property that may be found in the public records of this count am < a there may be additional permits required from other governmental entities such as water management districts,state agenjos8r CC Z, 1�, federal agencies. u ILL cc OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance witul mr. W applicable laws regulating construction and zoning. U. LL RE 2 0 W W in CL cc M WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAT � uj 5 a 0 RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTiNu CUDJ W LU TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ORA 'ATTORNEYBEFORE > W RECO I;E ,��G YOUR NOT ' Of_�COMMENCEMENT. L (Signature of Owner or Agent) (gig'natur—eof Contractor) Signed and sworii to(or affirmKI)before me th; ay Sigr)f and swor to or affir hie day of day by by L-14 tu�a SCNL ALLEN L POUCHER S BERG Notary Pub!ic-State of E ASETH Florida --giate of Florida Commission#GG 264094 ,/Personally Known OR -Notary"lic, [ I Personally Kn 13' my Comm.Expires Oct 1,2022 ]Produced Identification MY Comm.Expires 06/1421 [ ] Produced Ide i fi c,a I.. , Type of Identification:_ Commission No.613106811 Type of Identific n- nded through National Notary Assn. / 't NOTICE OF COMMENCEMENT 71 c? Tax Folio No. State of County of a, y aj To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information'is stated in th' ICE OF COMMENCEMENT. Legal Description of property being improved: 4 11, Address of property being improved: o dqo-b a 1, , 3 't General description of improvemen s: Uj Oi t;Ztj�A.AC"E� t Owner:'2�Q,nyl,e Address: 144.m —7c—c-46nuldli Owner's interest in site of the impt Fee Simple Titleholder(if other than owner): Name: Contractor: li. Address: 7-1)tv k:5�- Re Telephone No.4, Fax No: Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Doc#2019155994,OR BK 18852 Page 81, Name and address of any person making a loan for the construction of the improvements Number Pages: 1 Recorded 07/03/2019 02:43 PM, Name: RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL Address: COUNTY RECORDING $10.00 Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served:Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORIDER'S USE ONLY OWNER Signed�—�211� Date: Before me this ?,<,�C day of n the�ounty of Duval,Staie EUZABETH SCHLOSSBERG Of Florida,has personally appeared �m-r,et e- --*4qu-,5e)n Notary Public,State of Florida Notary Public at Large,State of Florida,County of Duv My Comm.Expires 06/12/21 My commission exp.W: Commission No.GG106811 Personally Known: A or Produced Identification: -----------------j FULL FRAME REPLACEMENT WITH NAIL FIN INSTALLATION OF NEW NAIL FIN WINDOWS AFTER THE REMOVAL OF EXISTING WINDOWS AND THE SURROUNDING TRIM OR SIDING fW1w fin OFFICE COPY 0�77 R.N P, -g I�Ih g P�12 AiisM.9 Ch-k-, PREPARE THE OPENING 2SETTING AND FASTENING THE WINDOW Refer to the existing frame removal instruction and nail A. Insert the window into the opening on the sill fin installation preparation sections at the beginning of spacers.Center the window between jambs. this booklet. 1 C B. Drive two fasteners,one near each end of the top A. Repair the wall surface around the opening(if nailing fin.See the nail fin anchor instructions a necessary)by installing new blocking flush with the ;J at the end of this booklet for fastener surface of the existing sheathing and/or repairing requirements. the existing building wrap with flashing tape. C. Plumb and square the window B B. Cut 2 pieces of flashing tape 12"longer than 1D using shims at the locations shown. opening width. Adjust shims to plumb and square C. Apply sill flashing tape#1 extending far enough the window.Keep shims 112"short of onto the wall surface to overlap the building wrap 1 window frame depth. or onto the top edge of the siding and 6"up each 1 E NOTE:DO NOT shim above the window Additional shims are required jamb. at screw locations for large units and Inteno, InteriorView D. Cut 1"wide tabs at each corner by tearing the foil combinations.See 112"each way from corner. E. Apply sill flashing tape#2 overlapping tape#1 by the nail fin anchor 1"minimum. instructions at the end of this booklet. If existing building wrap is folded into the opening Mid at the jambs,skip to step 1 H. D. Check the window Mid F. Cut 2 pieces of flashing tape.Make one equal to placement by the height of each side of the opening. measuring from the interior surface of G. Apply one piece on each jamb starting 1"from the window frame or the exterior.of the framing,over the edge of the jamb extension to the over 53'tal�l sheathing and onto the surface of the sheathing.. interior surface of the wall for consistency. NOTE:PRESS ALL FLASHING TAPE DOWN FIRMLY If the dimensions are not Interior H. Install and level sill shims.Place 1"wide x 1/4"to equal,confirm the fins are folded fully to 90'(if 2D 2C 3/8"thick shims 112"from each side. All Keep shims back from interior face of applicable). /6 F] window.Place additional shims under E. Drive two fasteners one near each mullion and sliding window B each end of the sill nailing interlocker. fi n. For vinyl windows,add shims so F Check window operation. maximum spacing is 18". Vent awning and casement:See lock lever AJ 1. Attach shims to prevent movement and cran k handle instructions at the end of this after they are level. instruction.Lift the lock lever and turn the crank handle to open the window.Remove the shipping NOTE:Improper placement of shims may result in spacers.Open and close the window to test for bowing the bottom of the window proper operation. J- Apply a continuous,3/8"tall bead of sealant 112" Double Hung:Cut the checkrail bands(if applicable)and remove from the edge of the opening at the sides and top shipping spacers.Open,close and tilt the sashes to test for proper only.Do NOT apply sealant at the sill.This step operation.Check for equal sash to frame reveal from top to bottom. may be omitted if there will be at least 3"of wall NOTE:Adjust shims to correct any issues with plumb,square,operation surface between the edge of the window frame orreveal. and the siding after installation. G. Close and lock the window. H. Finish driving fasteners into the nailing fin.Refer to the nail fin anchor instructions at the end of this booklet. NF-15 Revised 03/22/2019 0 2019 Pella Corporation FF-NF FULL FRAME REPLACEMENT WITH NAIL FIN (CONTINUED) INSTALLATION OF NEW NAIL FIN WINDOWS AFTER THE REMOVAL OF EXISTING WINDOWS AND THE SURROUNDING TRIM OR SIDING 3SEALING THE TOP AND SIDE NAILING FINS NOTE.Apply flashing tape 112"onto C. Apply top flashing tape. frame cladding with fold-up or slide-in Rectangular Units:Cut one piece of fins.Pre-fold flashing tape at 112"to Flashingz flashing tape to extend 1"past both assist with application.For siding less Tap side flashing tapes. 3C : than 112"thick,adjust the placement of the tape to allow the exterior Curved Top Units:Using several short sealant to cover the tape edge. pieces,start taping from the sides of the window working towards the peak. Cut each piece short enough so each piece overlaps the previous piece. Tighter curved frames will require shorter pieces of tape. Curved and angle top units without pre-applied fin corners: A. Cut four 1-1/2"long pieces of flashing tape. Apply one to each end of sill fin to extend it 1-112"past each jamb. Apply one to the bottom end of each jamb fin beginning 1-112"from the end of the fin and lapping over the first piece of flashing tape. If there is less than 3'between the window frame and the siding,skip to step 3C. NOTE:DO NOT TAPE OVER BOTTOM NAILING FIN. NOTE:PRESS ALL FLASHING TAPE DOWN FIRMLY D_ Install head flashing if none exists,properly incorporating it with the 2�d siding and building wrap according to applicable code requirements. E. Install blocking forframe expander support or solid trim at this time,if I applicable. F. Install interior sealant.Refer to the interior sealant instructions at the end of this booklet. G. Install exterior sealant.Refer to the exterior sealant instructions at the end of this booklet. H. Install frame expander and receptor(if applicable).See separate B. Apply straight side flashing tape.Cut two instructions. pieces of flashing tape 4"taller than straight 3B 3 H 3 H sides.Apply tape over the fin and onto weather resistive barrier.Extend tape 2" above and below straight sides. _G� Angle top units:On the short side,do not allow the side tape to extend higher than what the top tape will cover. Lig NF-16 Revised 03/22/2019 C 2019 Pella Corporation I I 2�1 �FA NAIL FIN WINDOW ANCHOR INSTRUCTIONS Note:Standard performance only.Additional anchoring may be required for performance upgrade,impact resistant products or to comply with local building code requirements. PLACE FASTENERS AT THE LOCATIONS INDICATED. 250 SERIES E E s HP Nail Fin Frame with Frame Filler Single-,Ciouble-Hung Sliding Window X0 OX S E E E Aflachmentdp Clip Installation for Mullions SW Vent TracK SW Pocket Filler a Drill(2)5/32"holes and install F 1 -1 (2)#10 x 1-1/2"screws per clip. ®r ) _F Plug 0 0 Sliding Window XGX I Seff-adhesive spacer Pocket Cover Removal Casement HP Frame Filler ENCOMPASS BY PELLA*/THERMASTAR BY PELLAO/PELLA' 250 SERIES AND PELLAO 350 SERIES WINDOWS PG Max Frame Max Frame Edge Max. AnchorType Product Rating Width Height Spacing Intermediate Anchor Cluster (inches) (inches) (E) Spacing(s) Wood Every Other Pre-Punched 2"11 Ga.Roofing Nail Additional nails at 3"and 6"on both sides of the transition mullion at head and sill. Encompass and High Performance DH:(3)#10 x 2'jamb ThermaStar frame screws,4'apart at checkrails.Use(4) Windows so Any Any Every Pre-Punched Hole #8 x 2"Screw with Washer #10 x 2"screws at head mullion ends and 4 clips at sill mullion ends 3"and 6"from i mullion. Windows/CM Every Other Pre-Punched /AW <50 Any Any Hole 1.5"11 Ga.Roofing Nail High Performance DH:(3)#8 x 2"jamb frame screws,4*apart at checkrails. SH/SW/FX 50 Any Any Every Pre-Punched Hole 1.5"11 Ga.Roofing Nail U, Of W DH 50 Any Any Every Pre-Punched Hole #10 x 2'Screw with Washer —3 jamb frame screws,4"apart at Checkrails. U0 a CM/AW 50 Any Any Every Pre-Punched Hole #10 x 2*Screw with Washer None LO CN Combinations <35 Any Any Fvery Other Pre-Punched #8 x 2"Screw with Washer (6)#8 x 2'screws at head mullion ends Hole spaced 2"apart OR(4)#10 x 2"screws in Combinations >35 Any Any Every Pre-Punched Hole #8 x 2"Screw with Washer each end anchor. 30 40" 63" 6" 81 1.5"11 Ga.Roofing Nail None SH and DH 40 40" 63" 6" 8. 1.5"11 Ga.Roofing Nail 5 nails,2'apart at Checkrails +40/-60 Any Any 6" 8" 1.5"11 Ga.Roofing Nail 5 nails,2"apart at Checkrails and Mullion Ends 2-Panel 30 76" 48" 6" 8" 1.5"11 Ga.Roofing Nail None in Sliding 40 76" 62" 6' 8" 1.5"11 Ga.Roofing Nail 5 nails,2 inches apart Meeting Stiles X Windows 140/-60 76" 72" 6- 8" #10 x 2"Screw with Washer 3 Screws,2"apart at Meeting Stiles UJI Ln 0 3-Panel 30 123" 48* 6* 8" 1.5"11 Ga.Roofing Nail None Ln 8. Sliding 40 123" 62" 6* 1.5"11 Ga.Roofing Nail 5 nails,2"apart at Meeting Stiles Windows All Other Any Any 6" 8. #10 x 2"Screw with Washer 5 Screws,2.apart at Meeting Stiles CM/AW/FX 40 Any Any 6" 81, 1.5"11 Ga.Roofing Nail None 60 Any Any 4" 4" 1.5"11 Ga.Roofing Nail None FX Composites All Any Any 4" 4" 1.5"11 Ga.Roofing Nail 5 nails,2"apart at Mullion Err ds IMPORTANT.For installations over continuous exterior insulation,the anchor length must be increased by the thickness of the insulating panels For light gauge steel framing,use#10 self-drilling modified truss head screws. Refer to the supplemental instruction included with the unit for securing mullion end � High Performance Frame Fillers are required at each jamb anchor location. anchors(if applicable). NOTE:Do not over-drive fasteners,but allow for movement of building materials. When screws are used in the Nail-Fin,a 1'fender washer is required at each screw anchor location. NF-17 Revised 03/22/2019 Q 2019 Pella Corporation FF_NF �Pi& NAIL FIN WINDOW ANCHOR INSTRUCTIONS (CONTINUED) Note:Standard performance only.Additional anchoring maybe required for performance upgrade,impact resistant products or to comply with local building code requirements. PELLA@ IMPERVIA,ARCHITECT SERIES*(850)AND PELLA@ LIFESTYLE SERIES NAIL FIN ANCHOR SPACING INSTRUCTIONS PG Max Max Edge Max. AnchorType Product Rating Frame Frame Spacing Intermediate Frame Anchors Width Height (E) Spacing(S) Wood (inches) (inches) Impervia Windows All Any Any 3" 71, 2"11 Ga.Roofing Nail None All 73" 73" Every Pre-Punched 2"11 Ga.Roofing Nail None Architect Series&Lifestyle Series I #10 x 3-1/2'Screws at 1/3 Clad Wood CM,AW or FX Windows All >73" >73" Every Pre-Punched Hole 2"11 Ga.Roofing Nail points along head and iambs Architect Series&Lifestyle Series All Any Any Every Pre-Punched Hole 2"11 Ga.Roofing Nail None SH or DH Windows Monumental DH All <54 <96 Every Pre-Punched Ho 1-112"11 Ga.Roofing Nail Refer to the next page for le units larger than 54 x 96 Clad Wood Curved Shape Windows with Flexible Fin (2)#6 x 5/8"holding each or Wide EncluraClad Exterior trim All Any Any 6" 16"'* (2)#6 x 1-112"screw.-per clip clip** to the window frame with narrow fin. Clad Wood Curved Windows with Rigid Fin All Any Any 6' 12" 2"11 Ga.Roofing N il None IMPORTANT.For installations over continuous exterior insulation,the anchor length must be increased by the thickness of the insulating panels. For light gauge steel framing,use#10 self-drilling modified truss Refer to the supplemental instruction included with the unit for securing head screws. mullion end anchors(if applicable). Refer to the Pellal'EnduraCladO Exterior trim with narrow nailing fin Clad wood direct set windows achieve PG50 up to 60"x 60"with standard anchoring instructions. anchoring.Larger sizes achieve PG40.Refer to advanced performance/im pact NOTE:Do not over-drive fasteners in vinyl fins,but allow for movement resistant instructions for other options. of building materials. EXAMPLE ANCHOR TYPES A Roofing Nail K-Lath/Modified Truss Head Screw >73" 1/3 1 1/3 1/3 #10 x 3-1/ corrosion r2ls'tant wood screw 1/3 1/3 cor r 1 0 w 0 0 'o 0 x 3 n d s r >73" 1/3 1/3 — ] Fixed Extruded Fin Drill 1/8" diameter pilot 1/3 1/3 holle throug,In the clearance Drill 1/8"diameter Holes for Screws not required a-t the sill.- 1 hole in the frame windows with curved rigid fin Add installation clips orfrarne anchor screws for vent and fixed clad-wood casements over 73" #6�x 5/8- orrosion resistant screws 0 6"from end 76 6,5 "corro'ion es'stan,screws Lip rr)c?,k N10 Ch p Ins"taILIClips or frame screws for windows with non-structural curved flex fins. Qri� N F- 18 Revised 03/22/2019 Q 2019 Pella Corporation FF_NF �PAUNITS WITH WIDE PELLAx ENDURACLAD" EXTERIOR TRIM WITH NARROW FINS AND NO PRE- PUNCHED HOLES ANCHOR INSTRUCTIONS AND MONUMENTAL HUNG > S4" X 96" Note:Standard performance only.Additional anchoring may be required for performance upgrade,impact resistant products or to comply with local building code requirements. Units with narrow fins and NO pre-punched holes must be anchored using frame screws or installation clips. EVE" M2 M2 These fins are for flashing purposes only. I Units installed over continuous exterior insulation must be anchored using installation clips E PLACE FRAME SCREWS OR CLIPS AT THE LOCATIONS INDICATED EVERY s M2 EVERY M2 M, S E 5 fM2 E jM, M2 Im 1T T-T E JM2 T* EVERY Tr EVERY EVERY EVERY s 5 s _J I ARCHITECT SERIES (850)AND PELLA� LIFESTYLE SERIES WINDOW ANCHOR SPACING INSTRUCTIONS Edge Max. First Second Fastener Intermediate; Mullion Mullion Product Spacing Special Notes Spacing 1 Anchor Anchor (E) (S) (Mi) (M2) Wood Casement/ 6" #8 x 3" Awning Finish Screw E�­­t—w,th n.rrow fin Forwindows with integrated RoIscreen9 retractable screen,drive Doubl or 6" 16" 3 6" #8 x 3" jamb screws at each actory pre-punched hole in the jamb liner. Single-Hung Finish Screw Add fasteners as necessary,driving the head past flush of the jamb liner.Avoid RoIscreen components in the head and sill. #8 x 3" Fixed Frame 6 16" 3" 6" Finish Screw 06 Remove sashes and jamb liners.Drive 1 screw though each .6 x 1-1/2m mm jamb liner sutport caliNd(top,bottom,checkrail and center of Monumental DH (h-,!) 16"(head) 3" 6" #8 x 3" each sash). ve 2 itional screws through the frame(or x sm'—w >54"x 96" Screw ecure clips)3'above and below the checkrail on each iamb. iint-- Drive additional screws throu htheframe(or secure c ips) li-fi—-d achg centered between e amb,,ner suppo rt clip. Z M1 anchor required if design pressure exceeds 20 psf. up For light gauge steel framing,use#10 self-drilling/self-tapping screws;For concrete or masonry,use 3/16"masonry screws with 1-1/4"minimum embedment. 1/8" Pilot Hole Locations Casement/Awning Lifestyle Series Doubie-Hung Architect Series Double-Hung Monumental-Hung Monumental Hung ja b liner support clip Units h wit Integrated RoIscreen Pry Here Pry off Monumental Double-Hung jamb liner Do not install fasteners Not applicable for units with Sill anchors not required. through operator cutout. Integrated RoIscreen U, Clad Frame Head/Jamb/SiN NF-19 Revised 03/22/2019 0 2019 Pella Corporation FF_NF fWA INTERIOR AND EXTERIOR SEALANT Interior Sealant Instructions A CAUTION:Use low pressure polyurethane window and door insulating foams.Follow the Interio, directions on the can.Do not use high pressure or latex foams. A. Insert the nozzle or straw between the rough opening and window frame from the interior.Use a pliers(if necessary)to compress the end of a straw tube to allow it to fit in tight openings. B. Place a 1"deep bead of foam approximately 1"from the interior of the frame to allow for A expansion.DO NOT fill the entire depth of the rough opening cavity. NOTE:Apply foam between the frame and rough opening,NOTbetweenjamb extensions and the rough opening. C. To ensure a continuous interior seal,apply sealant over the interior surface of any shims or clips interrupting the foam seal. Backer rod(as necessary)and sealant can be used in place of the low expansion foam to create the interior seal.However,foam has greater insulating properties.Fiberglass batt or similar insulation is not recommended as it can absorb water and does not act as an air seal. NOTE:Use a low odor,paintable sealant such as Pella Window and Door Installation Sealant. Re-check window operation and remove shipping spacers after foam installation.Excess foam may be removed with a serrated knife after it cures. Exterior Sealant Instructions - - - - - - - - - - - - - - CAUTION:Use a high quality,multi-purpose exterior sealant such as Pella Window and Door Installation Sealant.Follow the directions on the cartridge. --- ___j When applying siding,brick veneer,flashing,or other exterior finish materials,leave adequate space —4 1 between the window frame and the material for sealant application. A A. Insert backer rod 3/8"deep in the space around the window.Backer rod adds shape and controls the depth of the sealant line. B B. Apply a continuous bead of sealant to the entire perimeter of the window. C. Shape,tool and clean excess sealant.When finished,the sealant should be the shape of an hourglass. NOTE:The siding details below apply to windows without a J-mould as part of the frame.The J-mould frame is only intended for vinyl or metal sidings where the siding is extended behind the i-mould portion of the frame.The J-mould should be removed and replaced with backer rod and sealant with all other siding or trim types. BRICK VENEER SIDING SIDING VVITH TRIM Backer Rod and Sealant typical Sealant typical Sealant typical 3/8"Clearance 1/8"Clearance 3/8"Clearance Access ry Insulating Accessory Groove f Groove' Accessory Groove Perimeter Sealant Insulating Insu Perimeter Sealant Foam must extend to room Foam Foam must extend to room side of Accessory side of Accessory Groove. nsu z Groove. Foam .1 11/8 —3/ M Min. NF-20 Revised 03/22/2019 Q 2019 Pella Corporation FF_NF M 7 sk w WALL CONSTRUCTION OFFICE COPY Building codes require that walls resist wind pressures caused by the design wind speeds,resist wall-racking forces and provide weather protection.This section provides details on how wood structural panels can be used to meet these fundamental requirements. APA Sturd-l-WaI110 The APA Sturd-l-Wall system consists of APA RATED SIDING(panel or lap)applied direct to studs or over nonstruc- tural fiberboard,gypsum or rigid foam insulation sheathing*. Nonstructural sheathing is defined as sheathing not recognized by building codes for meeting both bending and racking strength requirements. *Where panel siding is applied over foam sheathing,see APA publication ARA Rated Siding Panels ovo RiJd Foam Insulation Sheathing,Form C465. TABLE 19 FASTENING APA RATED SIDING (PANEL)APPLIED DIRECT-TO-STUDS OR OVER NONSTRUCTURAL SHEATHING(,)[I)(�)(d)�,) Minimum NaiV) Panel Nail Spacing Maximum Wind Speed(mph) Shank Penetration Wall Stud Intermediate Wind Exposure Category APA Rated Diameter in Framing Spacing Edges(") Supports Panel Siding (i n.) (i n.) (in.o.c.) (in.o.c.) (in.o.c.) 6 C D 3/8 Perf.rIll.r1ce 16 6 12 110 90 90 Category 1.5 6 140 120 110 APA MDO 12 90 NP NP GENERAL 24 6 6 130 110 100 APA Rated Siding 0.113 - 12 125 105 90 16 oc 16 6 6 140 120 110 APA Rated Siding 2.0 12 100 85 NP 24 oc 24 6 6 140 120 110 (a)Table is based on wind pressures cti toward and away from (d)Hot-dip galvanized nails are recommended for most siding building surfaces,at 30-ft height in=?I Zone 5(corners)with applications,see Siding Fasteners section an page 48 for more smallest effective area,per Section 6.4.2.2 of ASCE 7-05 and information. Section R301.2 of the 2009 IRC.Stud specific gravity=0.42. (a)Maximum stud spacing shall be in accordance with Table 21A. (b)Recommendations of siding manufacturer may vary. If) See Table 5,page 14,for nail dimensions. (c) For use as wood structural panel wall bracing,the minimum (g)Supported panel joints shall occur approximately along the center- fastener spacing of 6'o.c.at panel edges and 12"o.c.at interme- line of framing with a minimum bearing of 1/2'.Fasteners shall 'diate supports shall be sufficient except: be located 3/8"from panel edges.Siding installed over two or (1)For braced wall section with Performance Category 3/8 panel more spans. siding applied horizontally over studs 24"o.c.,space nails 3*o.c.along panel edges. 45 ENGINEERED WOOD CONSTRUCTION GUIDE-FORM NO.B360P-C 2011 APA-THE ENGINEERED WOOD ASSOCIATION-WWW.APAWOOD.ORG Wall Construction TABLE 20 APA RATED LAP SIDING APPLIED DIRECT-TO-STUDS OR OVER NONSTRUCTURAL SHEATHINGto)(b)(old)(0 - Minimum Nail(') - Minimum Wall Stud Maximum Wind Speed(mph) Shank Diameter Penetration in Performance Spacing Lap Siding Wind Exposure Category (in.) Framing(in.) Category(in.) (in.o.c.) Width(in.) B C D 6 140 120 110 3/8 16 8 140 120 110 12 120 100 90 6 140 120 110 0.113 1.5 7/16 16 8 140 120 110 12 120 100 90 6 140 120 110 7/16 24 8 120 100 90 12 90 NP NP (a)Table is based on wind pressures acting toward and away from (d)Hot-dip galvanized nails are recommended for most siding applica- building surfaces,at 30-ft height in wall Zone 5(corners)with tions,see Siding Fasteners section of page 48 for more information. smallest effective area,per Section 6.4.2.2 of ASCE 7-05 and (e)Supported panel joints shall occur approximately along the center- Section R301.2 of the 2009 IRC,Stud specific gravity=0.42. line of framing with a minimum bearing of 1/2".Fasteners shall (b)Recommendations of siding manufacturer may vary. be located 3/8"from panel edges.Siding installed over two or (c)APA Rated lop siding rated 16 oc and 24 oc shall be used with more spans. a maximum stud spacing of Wo.c.and 24"o.c.,respectively. (f) See Table 5,page 14,for nail dimensions. TABLE 2]A MAMMUM STUD SPACING:APA RATED SIDING(PANEL)APPLIED DIRECT-TO-STUDS OR STRUCTURAL SHEATHING Minimum Performance Maximum Stud Spacing(in.)for Vertical Rows of Nails Category or Siding Description Span Rating Parallel to Supports Perpendicular to Supports APA MDO GENERAL 3/8 16 24 15/32 24 24 16 oc: 16 16M APA Rated Siding 24 oc: 24 24 (a)Stud spacing may be 24'o.c.for veneer-faced siding panels. TABLE 21B APA RATED SIDING(PANEL)APPLIED TO STRUCTURAL SHEATHING(a)(b)(c)(d)(e) Minimum Nail(l)(9) Panel Nail Spacing Maximum Wind Speed(mph) Wall Stud Intermediate Wind Exposure Category APA Rated Shank Diameter Spacing Edges(h) Supports Panel Siding (in.) (in.-o.c.) (in.o.c.) (in.o.c.) B C D 3/8 Performance Category 16 6 12 110 90 85 APA MDO GENERAL 0.120 ring shank 6 125 105 90 APA Rated Siding 12 90 NP NP 16 oc:or 24 oc 24 6 6 110 90 85 (a)Table is based on wind pressures acting toward and away from (d)Hot-dip galvanized nails are recommended for most siding applica- building surfaces,at 30-ft height in wall Zone 5(corners)with tions,see Siding Fasteners section on page 48 for more information. smallest effective area,per Section 6.4.2.2 of ASCE 7-05 and (e)Maximum stud spacing shall be in accordance with Table 21A. Section R301.2 of the 2009 IRC,Stud specific gravity=0.42. (f) Ring shank nail shall be used. (b)Recommendations of siding manufacturer may vary. (g)See Table 5,page 14,for nail dimensions. (c) For use as wood structural panel wall bracing,the minimum fas- tener spacing of 6"o.c.at panel edges and 12"o.c.at intermediate (h)Supported panel joints shall occur approximately along the center- supports shall be sufficient. line of framing with a minimum bearing of 1/2".Fasteners shall be located 3/8"from panel edges. 46 ENGINEERED WOOD CONSTRUCTION GUIDE-FORM NO.B360P-C 2011 APA-THE ENGINEERED WOOD ASSOCIATION-WWW.APAWOOD.ORG Wall Construction A single layer of wood structural panel siding,since it is strong and rack resistant,eliminates the cost of installing separate structural sheathing or diagonal wall bracing.Panel sidings are normally installed vertically,but may also be placed hori- zontally(long dimension across supports)if horizontal joints are blocked.Maximum stud spacings for both applications are given in Tables 19,20 and 2 1. When installing panel or lap siding over rigid foam insulation sheathing,drive the nails flush with the siding surface, but avoid over-driving,which can result in dimpling of the siding due to the compressible nature of foam sheathing. Sidings are occasionally treated with water repellents or wood preservatives to improve finishing characteristics or mois- ture resistance for certain applications.If the siding has been treated,allowing the surface treatment to dry will avoid solvent or chemical reaction with the foam sheathing. When rigid foam insulation sheathing is used,building codes also generally require installation of 1/2-inch gypsum wallboard, or other materials of the required thermal barrier rating,on the inside surface of the wall for fire protection. See Figures 8 through 12 for panel and lap siding installation recommendations for the Sturd-I-Wall system or for siding installed over nailable sheathing.See APA's Build A Better Home:Walls,Form A530,for additional recommended details to avoid moisture penetration in walls. All panel siding edges in Sturd-l-Wall construction should be backed with framing or blocking.Use nonstaining,non- corrosive nails as described in Tables 19,20 and 21 to prevent staining the siding. Where siding is to be applied at an angle,install only over wood structural panel sheathing. Note:Gluing of siding to framing is not recommended due to the increased potential for panel buckling. APA APA FIGURE 8 RATED SIDING RATED SIDING APA STURD-11-WALL(Vertical Pan*1 Installation) LAP 3 303-30-SIMI 03-18-srw 160C GROUP I 160C GROUPI SMD FOR PACING EXTERIOR EXTERIOR Building paper or code- THICKNESS 0,451 IN. THICKNESS 0.578 IN, recognized weather-resistive 000— F", Boo— F1 I-" barrier required behind siding sz�lu No— Nu�" 1VQ CATEGC�y 11M CATEGORY Panel siding meets code APAAP7 requirements for wall bracing RATED SIDING RATED SIDING LAP 240C GROUP I 6oc �FOR PACING APA RATED SIDING panels. ICEXTERIOR EXTERIOR TH KNESS'.451 IN. THICKNESS 0 578 IN. All edges supported by framing 000— —000— or blocking. ISCQ CATEGORY 11WCATEGORY 1/8'spacing is recommended at all edge and end joints unless otherwise indicated by panel manufacturer 6*minimum clearance, siding to grade 47 ENGINEERED WOOD CONSTRUCTION GUIDE FORM NO.B360P-C 2011 APA-THE ENGINEERED WOOD ASSOCIATION WWWAPAW0OD.ORG Wall Construction For other fastener types,refer to Table 22.It provides the withdrawal resistance for a number of different fastener types (smooth-,ring-and screw-shank nails;wood screws and vinyl siding nails).Together with the wind load tables in the 2006 and 2009 International Residential Codes,IRC Tables R301.2(2)and R301.2(3),the attachment schedules for any combination of siding type,continuous wood structural panel sheathing,design wind speed and exposure can be determined.See ARA Technical Topic:Wood Structural Panels Used as Nailable Sheathing,Form TT-109 for more information including wind load tables and a sample calculation. TABLE 22 FASTENER WITHDRAWAL LOADS FOR THE ATTACHMENT OF SIDING TO CONTINUOUS WOOD STRUCTURAL PANEL WALL SHEATHINGM Ring-Shank Nails(414 Withdrawal Loads(Ibf Wall Sheathing Nail Diameter(in.) — Performance 0.097 Category 0.091 0.094 0.099 0.113 0.120 0.128 0.135 0.148 3/8 31 32 33 38 41 43 46 50 7/16 36 37 38 45 48 51 53 59 15/32 and 1/2 39 40 41 48 51 54 57 63 19/32 and 5/8 49 51 52 61 64 69 73 80 23/32 and 3/4 59 61 63 74 78 83 88 96 Wood Screws1c)(d)Withdrawal Loads(lbf) Wall Sheathing Screw Gauge/Diameter(in.) Performance #6 #7 #8 #9 #10 #12 #14 Category 0.138 0.151 0.164 0.177 0.19 0.216 0.242 3/8 48 52 57 61 66 75 84 7/16 56 61 66 72 77 87 98 15/32 and 1/2 60 65 71 77 82 93 105 19/32 and 5/8 76 83 90 97 104 118 133 23/32 and 3/4 92 100 109 117 126 143 161 Vinyl Siding Nails(c)[OV) Smooth-Shank and Screw-Shank Nails(,)(*)Withdrawal Loads(lbf) Withdrawal Loads Wall Sheathing Nail Diameter(in.) Nail Diameter(in.) Performance Category 0.092 0.099 0.113 0.120 0.128 0.131 0.135 0.148 0.122 0.125 — 3/8 8 8 9 10 11 11 11 12 10 10 7/16 9 10 11 12 13 13 13 14 12 12 15/32 and 1/2 10 10 12 13 13 14 14 16 13 13 19/32 and 5/8 12 13 15 16 17 17 18 20 16 17 23/32 and 3/4 15 16 18 19 21 21 22 24 20 20 (a)Withdrawal capacities are based on the duration of load factor of 1.6 for wind applications.Adjustments for wat service and temperature are normally not required for attachment to the wood structural panel noilable sheathing. (b)For ring-shank nails,the withdrawal capacities(W)are based on specific gravities(G)of 0.70 in accordance with APA TT-039 and W 1380 G1 I D C,I,where:W=Withdrawal capacity(1bf),G=Specific Gravity,D=Nail diameter(in.), Co Duration of load factor(1.6 for wind loads),and t=wood structural panel thickness(in.). (c) Fasteners shall be long enough to fully penetrate wood structural panel sheathing by at least 1/4 inch. (d)For wood screws,the withdrawal capacities(W)are based on specific gravities(G)of 0.45 in accordance with APA TT-051 and W 2850 GI D Ct,I,where:W=Withdrawal capacity(Ibf),G=Specific Gravity,D=Nail diameter(in.), Cu Duration of load factor(1.6 for wind loads),and I=wood structural panel thickness(in.). (e)For smooth-shank,screw-shank,and vinyl siding nails,the withdrawal capacities(W)are based on specific gravities(G)of 0.40 in accordance with APA TT-039 and W 1380 G2-5 D CD t,where:W=Withdrawal capacity(Ibf),G=Specific Gravity,D=Nail diameter(in.), CD Duration of load factor(1.6 for wind loads),and I=wood structural panel thickness(in.). (f) Vinyl siding nails shall have a head of at least 3/8 inch in diameter. 49 ENGINEERED WOOD CONSTRUCTION GUIDE-FORM NO.B360P-9 2011 APA-THE ENGINEERED WOOD ASSOCIATION-WWWAPAWOOD.ORG Wall Construction FIGURE 10 APA STURD-I-WALIL(Horizontal Lop Siding Installation)(1) Building paper or other code-recognized weather-resistive barrier required Leave 1/8"spacing and caulk vertical joints unless otherwise recommended by siding manufacturer ARA RATED SIDING(lap siding),maximum width 12'. Minimum headlap 1". 6"minimum clearance,siding to grade 1-1/2"-wide starter strip,thickness to match lap siding (a)For engineered shear wall segments or wall bracing requirements,use APA Rated Sheathing for wall sheathing under lap siding(see Figure 12).Other methods permitted by model building codes for braced wall segments may also be used. FIGURE I I APA RATED SIDING(PANEL SIDING) 0 VIER WOOD STRU CTURAL PANEL SHEATHING Building paper or other code-recognized weather-resistive barrier required ARA RATED SIDING panels applied over sheathing 6"minimum clearance,siding to grade 1/8"spacing is recommended at all edge and end joints unless otherwise indicated by panel manufacturer Panel siding or APA RATED SHEATHING meets code requirement for wall bracing FIGURE 12 APA RATED SIDING(LAP SIDING)OVER WOOD STRUCTURAL PANEL SHEATHING ARA RATED SHEATHING meets code requirement for wall bracing Building paper or other code-recognized weather-resistive barrier required APA RATED SIDING(lap siding),maximum width 12".Minimum headlap V. Siding joints,if staggered may occur away from studs with noilable sheathing 6"minimum clearance,siding to grade V Leave 1/8"spacing and caulk vertical joints,unless otherwise recommended by siding manufacturer 1-1/2"-wide starter strip,thickness to match lap siding 50 ENGINEERED WOOD CONSTRUCTION GUIDE-FORM NO.B360P-9)2011 APA-THE ENGINEERED WOOD ASSOCIATION WWWAPAWOOD.ORG Wall Construction TABLE 23 APA RATED LAP SIDING APPLIED DIRECT-TO-STUDS OR OVER STRUCTURAL SHEATHINGIII(b)(4 Minimum Maximum Wind Speed(mph) Minimum Nail Performance Shank Diameter(d) Category Fastener Spacing Lap Siding Width Wind Exposure Category (in.) Lap Siding (in.)(el (in.) B C D 6 130 110 100 0.113 3/8 6 8 110 90 85 12 85 NP NP (a)Table is based on wind pressures acting toward and away from (c) Hot-dip galvanized nails are recommended for most siding applica- building surfaces,at 30-ft height in wall Zone 5(corners)with tions,see Siding Fasteners section on page 48 for more information. smallest effective area,per Section 6.4.2.2 of ASCE 7-05 and (d)See Table 5,page 14,for nail dimensions. Section R301.2 of the 2009 IRC,Stud specific gravity 0.42. (e)Fastener spacing at top edge of lop siding. (b)Recommendations of siding manufacturer may vary. TABLE 24 APA RATED SHEATHING APPLIED DIRECT-TO-STUDSM(b) Minimum Panel Nail Spacing Maximum Wind Speed(mph) Minimum Nail(,) Wood Minimum Shank Minimum Structural Panel Wind Exposure Category Diameter Penetration Panel Span Performance Wall Stud Edges Field (in.) (in.) Rating Category Spacing(in.) (in.o.c.) (in.o.c.) 6 C D 24/0, Wall-16 and 3/8 16 6 12 110 90 85 0.113 1.5 wo-1-1-24 24/16, 7/16 16 6 12 110 100 90 Wall-24 6 150 125 110 12 130 110 105 0.131 1.75 24/16 7/16 16 6 6 150 125 110 W.111-2� 24 or less 6 12 110 90 85 (a)Panel strength axis parallel or perpendicular to supports.Three-ply (c) See Table 5,page 14,for nail dimensions. plywood sheathing with studs spaced more than 16"on center shall be applied with panel strength axis perpendicular to supports. (b)Table is based on wind pressures acting toward and away from building surfaces,at 30-ft height in wall Zone 5(corners)with smallest effective area,per Section 6.4.2.2 of ASCE 7-05 and Section R301.2 of the 2009 IRC,Stud specific gravity 0.42. 51 ENGINEERED WOOD CONSTRUCTION GUIDE-FORM NO.B360P C 2011 APA-THE ENGINEERED WOOD ASSOCIATION-WWW.APAWOOD.ORG APA Panel Wall Sheathing APA RATED SHEATHING meets building code wall sheathing require- APA APA APA ments for wind pressures and wall bracing. Even when foam or Other RATED SHEATHING RATED SHEATHING RATED SHEATHING nonstructural sheathing is used,APA RATED SHEATHING corner brac- 24/0 24/16 STRUCTURAL[ SUEDID AC.G SUEDIFIREPACNO 32/16 ing panels (Figure 14) of the same thickness meet code wall bracing EXPOSURE1 EXPOSURE1 SUED FOR SPACING THICKNESS 0.354 IN, THICKNESS 0.418 IN. EXPOSURE1 000— —000— THICKNESS 0.451 IN requirements.Installation recommendations are given in Figure 13 and —74 SHEATHWG Pl­SHEATHING —000 'R""HUD-UM40 PF-6 Hui,UM7" PS-GO PRP;'Ch Table 24. a CATEGORY 7M6CATEGWY 1E—ATECOR Recommended wall sheath- ing spans with brick veneer or FIGURE 13 masonry are the same as those APA PANEL WALL SHEATHING for panel sheathing(see Table 1/8'spacing is Building paper 24). See Figure 15 for instalia- recom ended or other code- m tion recommendations. at all edge and recognized end joints unless weather- 11 Panel recommendations for otherwise indicated resistive 1, by panel barrier preframed wall sections are the manufacturer same as for built-in-place walls. APA RATED SHEATHING Note: To minimize the potential APA RATED applied with for panel buckling, gluing of wall SHEATHING strength axis sheathing to framing is not recom- applied with parallel to mended,except when recommended strength axis studs by the adhesive manufacturer for across studs(,) wall sheathing that already has been permanently Protected by siding. Siding Filler strip if required (a)Check local building codes for blocking requirement between studs for braced or engineered 6"minimum shear wall segments,when wall sheathing clearance, is installed horizontally across studs. siding to grade FIGURE 14 FIGURE 15 APA PANEL CORNER BRACING BRICK VENEER OVER APA PANEL SHEATHING Supports 16" Building paper or other or 24"o.c. code-recognized weather- resistive barrier Any wall 1 air space required sheathing Brick veneer or masonry Min.3/8 Performance Category APA RATED SHEATHING "Weep holes" nailed to studs with 6d common in bottom course nails spaced APA RATED 6"o.c.along panel every 24" SHEATHING edges and 12"o.c. at intermediate Extend flashing up behind supports* weather-resistive barrier at least 6" *See Table 5 for noil dimensions Hold panel edge 1/2" above base flashing For additional information on wall bracing, see Introduction to Wall Bracing,Form F430. 52 ENGINEERED WOOD CONSTRUCTION GUIDE-FORM NO.B360P Q 2011 APA-THE ENGINEERED WOOD ASSOCIATION-WWWAPAWOOD.ORG