Loading...
1211 Mayport Rd ROW19-0018 RIGHT OF WAY PERMIT PERMIT NUMBER ROW 19-0018 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ISSUED: 7/17/2019 r »~ ATLANTIC BEACH. FL 32233 EXPIRES: 10/15/2019 MUST CALL INSPECTION PHONE LINE (904) 247-S814 BY 4 PM FOR NEXT DAY INSPECTION. ALL •RK MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' CODE, • OF • OF ORDINANCES . ALL CONDITIONS OF PERMIT • • PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. ! : ADDRESS: PERMIT TYPE: DESCRIPTION: OF • • 1211 MAYPORT RD RIGHT OF WAY SINGLE OR TWO HPE SDR11 & FIBER OPTIC $0.00 FAMILY RIGHT OF WAY CABLE TYPE OF ZONING: :D • CONSTRUCTION: GROUP: 177579 0000 SECTION LAND • ADDRESS: QUANTA TELECOMMUNICATION SERVICES, LLC ! ADDRESS: GIANT JACKSONVILLE LLC 1806 N FRANKLIN ST TAMPA FL 33602 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. Issued Date: 7/17/2019 1 of 2 RIGHT OF WAY PERMIT PERMIT NUMBER �S ROW19-0018 CITY OF ATLANTIC BEACH v, 800 SEMINOLE ROAD ISSUED: 7/17/2019 - Fiji ATLANTIC BEACH. FL 32233 EXPIRES: 10/15/2019 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way. 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 4 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 5 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL Notes: Any damage done to sidewalk must be repaired by Contractor. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date: 7/17/2019 2 of 2 City of Atlantic Beach APPLICATION NUMBER js Building Department c^GIVE (To be assigned by the Building Department.) ' 800 Seminole Road C�✓C `���W ._^o Atlantic Beach, Florida 32233-5 1 1 Phone(904)247-5826 Fax(9 4�5 Z 8 2019Date r E-mail: building-dept@coab.us ����++�� outed: Z_'as Laj City web-site: hftp://www.coab. s APPLICATION REVIEW AND TRACKING FORM Property Address: 1 z l ( V \ AuPoLT� Department review required Yes No Building Applicant: C� u j�IyT fJ T r-_,L-(—�rva Planning &Zoning Tree Administrator Project: I— ( �—�{'� P�'( � C L_� Public Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPL)CATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING , c PLANNING &ZONING Reviewed b ate: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ill- . City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 's 800 Seminole Road 1�o A Vy' ` n ,_DO 1 Atlantic Beach, Florida 32233-5445 l"� Phone(904)247-5826 - Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: `� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: t� Department review required Yes No _ Building Applicant: U 1`AtD-CA 1 Gt.- C©/Y1 Planning &Zoning �- Tree Administrator Project: I`` ( s?j � �P � � L Public Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept.of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLIC—AT40N STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: t1(�4. ate: — _— TREE ADMIN. Second Review: []Approved as revise . ❑Denied. []Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 rSr1Pl r�i r't RIGHT-OF-WAY /EASEMENT PERMIT ux,% Permit# Issued by the City of Atlantic Beach R® r) PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 1,V/ mAVPb&T tD Phone `904- G 3 3-5411 Permittee WJ rx&,o ke.56 7r2tnsm155/&?Ays CalP Email nWYiA .tiSher @ V21' J.AW7 Requesting Permission to Construct 4_ng 'P� I—.?'" i1Pf SDS// 4-Fi 1"E.41)&U_ Location (Reference to Cross-Street) PLAZA oW MAY 2 3 2019 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe a��eRme�t alteration or relocation of all,or any portion of said street or easement as determ�� �� 1, FL. Works,any or all said poles,wires,pipes,cables or other facilities and appurtenant authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of THOMAS "LLI-V (Project Superintendent) with Company Name &LLAA171k 7*LEtj rn Phone 4766 -6GG-I011 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. Is The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again (!!!nupon completion. Date S-a�3-/9 Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of �I�l ,20 by �W nr),M� �'Yl,L rbz-r— ,who personally appeared before me and (printed Mane of Permittee) ackn ledged that he/she signed the instrument voluntarily for the purpose expressed in it. P-,V,6/ Personally Known Si a of No Public,State of Florida Produced Identification(Type) HAMaster Forms\Publ - tilities Works Forms\ROW-Easement Permit 3.1.18.docx T�' Notary Public State or'' Tammy L Barber r My Commission GG 2115'I(PS '?p� Expires 05/09/2022 — REVOCABLE ENCROACHMENT PERMIT I2 J l May por+ Road REVOCABLE ENCROACHMENT PERMIT by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and W Irn-oval A[LtSS Tr'ansiniSSion S15 C40. of A* aCh,Florida,hereinafter referred to as"USER". Jcscksonw�ll-1 WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as 4911** d 1•20 AWE ADJW * Fn-C. 191 Neejsat'XL big&-W&AW L91119i Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address 2=.f Denei.S ST J4LUanUtUA AL. 3.2 204 • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes,Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. 0 This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. Date��a0/01_ Property Owne Agent(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this _day of q� ,20_�, by 1 1Y1r% L (;ar�, ,who personally appeared before me and (printed name Signer) S ac lac ledged that he/she signed the instrument voluntarily for the purpose expressed in it. d� e of Not Public,State of Florida Approved/Public Works Department: Personally � Produced Identification(Type) f3 f I\XC 1 Com)SC- Scott illiams,Pu is orks Director Y "Ay Notary(Votary Public State of Flo;is Tammy L Barber v My Commission GG 21576- '?o;a Expires 05/09/2022 May 23, 2019 To whom it may concern, I am the permit coordinator in the Jacksonville market for MClmeto Acess Transmission Services Corp. and Quanta Telecom. I received an email from Ms. Grace Mackey, dated 3-1-18, stating Quanta had provided the Florida contractor Licenses and we are able to pull permits. I have included the current Business Tax receipt for this year. Please let me know if any other documentation is needed.Also, please copy me on any correspondence for permitting issues. Thank you so much and have a great day!! Sincerely, Tammy Ratteree tratteree@ antatelcom.com / 770-361-4510 MILEAGE:0.92 PROJECT# 074664 MCImetro ACCESS TRANSMISSION SERVICES CORP OUTSIDE PLANT CONSTRUCTION FL J CVO F L02-000039-MAYPO RT ROAD WT CROSS STREETS: MAYPORT RD (SR-A1 A) & PLAZA RD ADDRESS of WORK: 1211 MAYPORT RD ATLANTIC BEACH , FL, 32233 PERMIT: 1710AICP 4 RT ATLB PLAZA NFID: 1710AICP 4 PROJECT DESCRIPTION: PERMIT APPLICATION - 4,872' OF PROPOSED UNDERGROUND INSTALLATION TELECOM QUANTA PERMIT# JAX_1710AICP_4_RT_ATLB_PLAZA RT-19 May 3,2019)AREYES INDEX ver►Zonbusr -Ht"iE T 0:n664 1 rl() FIR SHEET 2 INDEX s 3 LOCATION MAP , 4 KEY MAP 5 HAND HOLE DETAILS N # 6 BORE TYPICALS = ° F a 7 ITRENCH DETAIL o 8 SILT FENCE TYPE III & IV co 9 SILT FENCE CONSTRUCTION DETAILS U ° �� 10 HAND HOLE STORAGE DETAILS F 11 TYPICAL CORE REPAIR DETAIL E° ° U W 12 LEGEND s = 13-24 DESIGN SHEETS z o GN 25-27 TRAFFIC CONTROL TYPICALS ° Ln 1n W U Q DATE 4117119 ENGINEER OTS DRAWN BY MPS REVISIONS SCALE , HORIZONTAL 1'30 SHEET 2 OF 27 NFID 1710AICP 4 FONID— LOCATION JACKSONVILLE verizonbusiness JL C,T ^74664 " s QArdclla Rd K Donner Rd Donner Rd ) _ �a SaflRsh D, L N }�- ° U 1n WA,nbcOxk Ln j Ow 9�niW Rd ` I�.'1oZZO ow �, z OW RZ Q F H O U) U) W U Q DATE 4117119 ENGINEER QTS DRAWN BY MPS REVISIONS CONTACTS "" ENGINEERING&PERMITTING: VERIZON: AGENCY NAME PROJECT MANAGER:JASON CORTES PROJECT ENGINEER:MARVIN FISHER PROJECT ENGINEER:KEITH THOMPSON CONTACT:BILL PITTMAN - - - PHONE:(678)477-9000 PHONE:(904)687-6051 PHONE:(352)598.1736 DEPARTMENT:ATLANTIC BEACH DEPARTMENT OF PUBLIC UTILITIES EMAIL:JCORTES@QUANTATELCOM.COM PHONE:(904)247-5675 u PROJECT ENGINEER:DUSTIN MILLER PROJECT MANAGER:WILLIAM BLOOM ADDRESS:3975 JOHNS CREEK CT.,SUITE 200 PHONE:(904)426-4932 PHONE:(252)201-0326 EMAIL:bpi8man@coab.us SUWANEE,GA 30024 ADDRESS:902 ASSISI LANE JACKSONVILLE,FL 32233 SCALE ., OUTSIDE PLANT CONSTRUCTION: HORIZONTAL 130 DESIGN MANAGER:MICHAEL LINDSEY PROJECT MANAGER:TOM KELLEY PHONE:470-528-7147 PHONE:(470)6064211 FW SHEET 3 OF 27 EMAIL:MLINDSEY@QUANTATELCOM.COM EMAIL:TKELLEY@QUANTATELCOM.COM 'z: ,. NFID 1710AICP 4 FQNID- m D 00 N N N N o T i F" e'p� MCImetro e a m AFse i ACCESS TRANSMISSION SERVICES CORP«, �a000».�.00a.Qo�om lacn Es- o O m ;ieE 'l, Z y b f OUTSIDE PLANT CONSTRUCTION y IJ k:R 3975 JOHNS CREEK CT ST 200 E SUWANEE,GA 30024 2.5' x 5' x 2.5' HANDHOLE DETAILS \� ~170nbusiness DETAIL"A" DETAIL"A-T' DETAIL"A-2" PROJECT 074664 EXPLODED ISOMETRIC DETAIL LOCK DOWN DEVICE ENGAGED LOCK NEOPRENE RUBBER DOWN DEVICE 1.1.-X 2S NEOPRENE COVER--,t STAINLESS STEEL SEE DETAIL-A1 .137SSCREW A ACMETHD.BOLTS THIS SHEET TWO PIECE REINFORCED WITH FLAT-7 CAPTURE NUT WI POLYMER MORTAR(RPM)COVER FORWASHER STAINLESS END CAP NONSKID 2D,I—UBS.LOADING MIGHT sl• O (SEIF CLEANING) a SURFACE LIFTING SLOT / al ! 4 EMS MARKER A-X r NTH CENTER PIN p 4 4 JM CAT/1411 Kz 'ONE SIDE ONLY) D P10y UNISTRUT LOCK DDVIN S DEVICE AND DIRT SHIELD SEE nErAIL•A-I• 7S IN. SECTION A-A THIS SHEET UMSTRUT CHANNEL 1#6¢4-56 LOCKING DEVICE TE SUP RT BEAM MIN CROSS SECTION DETAIL"A-3" 9 VV 1.625-X1-X33' S (3 REQUIRED) REINFORCED COVER HOLD DOWN BRACKET (L POLY MER MORTARIF OF 2-PIECE RPM COVER LOCKING BEAM COVER AND FRAMEO'CENTER ONLY) .075'INSERT 0 XVINSERT (TVP<PUCES)LS) ySEE OETAIL'A-2- i40 WTHIS SHEET REINFOZ to MORTAR FRAME(RPM)ED MOR TAR TO VAULT BY FBONDED T VAULT BY Lu USEE DETAL'A4' MANUFACTURER ]IJ 'THIS SHEET FIBERGLASS In FFR' F o FIBERGLASSREINFORCEDWTHJr X UT.HEX BOLT bZ y UM PLASTIC VAULT(FRP) VdTH NUT.AND WASHER O Y�a E— o wLD COVER HOLD DOWN � 2 _ U W w 3 REINFORCED DETAIL"B" BRACKET(HOT DIPPED U oz RIB GALV)'2 REG'D) Z a I. VAULT BOTTOM N R =3 PLAN VIEW DETAIL"A-4" Z o o N (144 SQ.IN.TOTAL DRAINAGE) a it SUPPORT BEAM F o n TYP. INSTALLATION 1'DA HOLE (TYP.AT 6 PLACES) In FOR GROUND ROD RPM COVER /n TYP-2 PL) W b 1r 4.50'BELL ENDSWIPJCJ LIFTING BOLTS(TYP.4 PLACES) �., P. T%S'GRAIN • ♦ > V PLUG.BELL ENDS TO S) 5950" .W OPENING(MAX) O O O O Q ACCOMODATE SCHED, r KNOCKOUT(BOTH END . (TVP 4PL) 0 40 WC(BOTH ENDS) ® RPM FRAME a I d SUPPORT p BEAM DRAWN BY P S2.50KNOCKOUT(BOTH ENDS) DATE4/17/19 ENGINEEROTS RFVI91mc DETAIL"C" DETAIL I'D" FIBERGLASS EXCAVATION PIT SIDE WALL VIEW VAULT - - - INSIDE LOOKING OUT PLAN PROFILE T-0' �( EMS MARKER = _ SUITABLE ORT I (ONE SIDE ONLY) 5-P EXISTING GRADE T BACKFILL NOTES: ' E 1.VOID IN EXCAVATED AREAS TO BE BACKFILLED b SUITABLE DPT T' R WITH SELECT MATERIAL. iu BACKFILL 2.BOTTOM OF EXCAVATED PIT TO BE BACKFILLED siie�w 4 b WITH 12'OF CRUSHED STONE(.TS GRADE), C—ENUCft NOT N HANDHOLE `�' / S.SHORING WILL BE REQUIRED. *s.icvcwvrtrz 4.15- /-\ 4.ALL HANDHOLES SHALL BE PLACED BELOW .osewSCALE ..E �5- NOTE: EXISANG GRADE . 5.TMS-DIOLEISOFFIBERGLASSIMTERIAL. HORIZONTAL. 1:30 IM LAG BOLT UNEAR DISTANCE BETWEEN APROXIMATELY POUNDS IN WEIGHT. 7CRUSHED STONE PJC,BBPIGSP ANCHOR(TYP.) LAG BOLT ANCHORS MUST THE UDS ARE POLYMER CONCRETE MATERIAL. OR HDPE BE 25'. EACH APPRO%IMATELY POUNDS. .SHEET 5 OF 27 CONDUIT(TVP.) NfTD 1710AICP_4 'OIJIC_ DIRECTIONAL BORE TYPICALS � ver►ZOnbusiness TYPICAL ROAD CROSSING PROJECT 074664 CROSS SECTION & DIRT ROAD WAY DIRT 56" LLa O FIBER OPTIC CABLE U U) w 2"HDPE CONDUIT U z PLACE BY DIRECTIONAL BORE w 0 t Z y U n a 0 O W(< JAIAI U U� ~ Uw _Lo � z o 0m O y TYPICAL DRIVEWAY /n w CROSS SECTION U U DATE. 4/17/18 ENGINEER. OTS DIRT DWY DIRT DRAWN BY MPS REVISIONS mvrrou wnus 5 i FIBER OPTIC CABLE 2"HDPE CONDUIT SCALE PLACE BY DIRECTIONAL BORE HORIZONTAL 1:30 SHEET 8 OF 27 NFID. 1710AICP 4 FONID- TRENCH DETAIL verizonbusiness M� F E%I6TIRD GRADE LL d It Q U 'MIN. BURIED CABLE (n MARKER TAPE III U z o xe-19-MIN. o F over W DEPENDING m N o HlsoicnoN HD(CROSSING F YI.D.HDPE EAV 0Z w UM FIBER OPTIC CABLEID Q ❑ W Q () W U� z �w 5 =; z ❑ �y F ~ O w W U II Q DATE 4117119 ENGINEER QTS DRAWN BY MPS REVISIONS SCALEmO�H u HORIZONTAL 1'.30 SHEET 7 OF 27 NFID 1710AICP 4 FQNID- SILT FENCE TYPE III & IV veriLonbusiness PROJECT 074664 PM(Op9ar.:Y.C a opl—I Port POWbn. —IDM P P.-I, M'INti p..W..e;SNN I ((C.—]11 TwoN ] ilo.) Flx.r nc.Fenrb Ze (� ,—eto S.c.995 IooT Spe.) 111111 b rn«F.eric 8 7II I I Sit Fb. b II • n b pll 4_____1 § SECTION t+ ELEVATION 3 TYPE III SILT FENCE 6 5 P—y—(20.w.Mm.) B 4 rnoT sD.e.7 3 w K Pwt(o�ptbnc r.r w oPtbnm PwI vmi ncW.Pert ve.A'n 1.aa la/n.wti.) 1D•ue.. nn«Tenn.(I F� w. F.I.F. d centennelK. n nn.r Fnxn� 0 s.c.De9 Fp01 Sp«.) I Q I I U W n b b •11 U z ELEVATION SECTION F N xa.� snt F.111 w Dere r„,,,,a..tn..enwn wt wb.t«sm.w sn F«...M. W ::) rn ry TYPE IV SILT FENCE p� �o N U n ZU o w p \ 2 Z5 °jn !sem !n .'.4115 Ty"III ,� SD1 Eric.rte. Q T�0 Dxcnr9otvppe.tom InMb. •P.otxlbn ]ATE 4/17/19 NGINEER QTS w ml e.goy in o moms IIM.in t.ce.11 pG s D evm m.�y.rmwnt la.�rq ..Iwcow.... 91l I.rc..on to M u..4 A updA baebl.aA wMAb lvrNr. "-IRANRJ RV MPS wM of D.rmamml n.44.d.Aw. SILT FENCE APPLICATIONS Fle. - lyp.N M P.11u TYM• 9R F.nc. _ M.e.e sp.a q W Tw.• F—In M In G, ...aYna. qrl 1.Mel.D-Doe .Ile AIN e..r.9w A er.xw9. Arvclum Alaw. SCALE�w SILT FENCE N.T.S. PLATE D-908 HORIZONTAL 1:30 TYPE III & IV DATE DRAWN 8-9-97 REVISED DATE 5-12-94 ;HEET 8 OF 27 :1 I(' 1710AICP 4 CONSTRUCTION DETAILS FOR SILT FENCES \/ V@flZQflbusiness PROJECT 074664 2. STAPLE WIRE FENCING TO 1. SET POSTS AND EXCAVATE A 4'x4' THE POSTS, TRENCH UPSLOPE ALONG THE LINE OF POSTS O U to 4' 4. BACKFILL AND COMPACT THE V Z EXCAVATED SOIL. O o It F n 3. ATTACH THE FILTER FABRIC TO O Lu F g THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. t T .5. Z rn U pQQ1 00 W 19 E rn I- W; i a x Z O �N uJ / E%TENSION OF FABRIC AND DATE'. 4/17/19 WIRE INTO THE TRENCH. ENGINEER-. OTS DRAWN BY MPS REVISIONS FILTER FABRIC . SCALES CONSTRUCTION DETAILS N.T.S. PLATE D-909 HORIZONTAL: 1:30 FOR DATE DRAWN 08/05/93 SILT FENCES SHEET 9 �� a7 REVISE➢ DATE 5-18-94 - NFID: 1710AICP 4 FONID- r verizonbusirim IROJECT 074664 HANDHOLE SLACK STORAGE DETAILS DETAIL"A" DETAIL"B" CABLE SLACK ARRANGEMENT HANDHOLE LAYOUT B CABLE RACK 4 ^ f LOOPDIRECTION ' a a O CABLE RACK CABLE RACK LOOP DIRECTION—► W U Z 30 O W5 N ry - 0 N Z U LOOP DIRECTION-+ NE�O O CABLE RACKU)CABLE RACK aa UW Wa� Alkali L- a 2 Z LU ❑ O'y �—LOOPDIRECTION+ 5 m CABLE RACK ~ 7 B N O n w W SECTION B-B 'I ¢ DATE 4/17/18 ' OUNTING INSERTS ENGINEER QTS E CASING IY EACH SIDE) DRAWN BY MPS REVISIONS CABLE RETAINERCABLE RETAINER 3JA4 SCALE . HORIZONTAL. 1:30 SHEET 10 OF 27 NFID 1710AICP 4 FONIO- TYPICAL CORE REPAIR DETAIL verjZp116usiness NOT TO SCALE PROJECT'.074664 ASPHALT MATERIALS o WILL BE REPLACED AT 6 8 INCH DIAMETER EXISTING ASPHALT z SAME DEPTH AS THICKNESS VARIES u EXISTING 4 5 FLOWABE FILL PLACED a TO THE TOP OF THE o EXISTING BASE If EXISTING BASE LAYER U U /n W W III- / ' O Z01 NOTE 0_ Z J W AN FOOT HOT MIXASPHALT OR AN APPROVED EQUAL(AQUAFAULT)WILL BE NATIVE FILL TO USED TO REPLACE THE CORED 98%COMPACTION / / / I Z g ASPHALT. /%///j%//%///% ti CUNDISTURBED p MATERIAL W W Q I 1=11I DATE: 4/17/79 NOTE: w?'•.:ti.:`j. 'a' �„.'��N j�• ENGINEERQTS SLURRY AND/OR SILT ANY SILT/SEDIMENT FILL LIQUIDS WILL BE t} n f; ,a,1+ - r. �= DRAWN BY MPS a� �C a�Vi -v� _�•: II II CONTAINED DURING THE CORING /'' t''` EXISTING UTILITY '{ REVISIONS PROCESS. THE MATERIAL REMOVED FROM THE CORE WILL BE DISPOSED OF OFF SITE ,>. .,,.; ,�•.%, III- e;41 INCH DIAMETER NOTE: c. AN FDOT APPROVED FLOWABLE FILL WILL BE USED TO BACKFILL THE HOLE UP TO THE TOP OF THE BASE LAYER. QUANTA WILL ASSURE THE MATERIAL SCALE .o MEETS THE MINIMUM STRENGTH HORIZONTAL: 1:30 REQUIRED BY USE OF A HANDHELD PENTROMETER PER 2018 FDOT SPECIFICATION SECTION 121-7 SHEET 17 OF 27 NFID 1710AICP 4 FONID— LEGEND veri7onbusiness 4-JE(_T 074684 GROUND SYMBOL(EXISTING) GROUND SYMBOL(PROPOSED) W WATER LINE DOWN GUY&ANCHOR(EXISTING) DOWN GUY&ANCHOR(PROPOSED) SD STORM DRAIN LINE S SIDEWALK DOWN GUY&ANCHOR(EXISTING) Y SIDEWALK DOWN GUY&ANCHOR(PROPOSED) SS SANITARY SEWER LINE 4q PROPOSED AERIAL M" STORM MAN HOLE(EXISTING) o HAND HOLE(EXISTING)30X6OX30 M" SANITARY SEWER MAN HOLE(EXISTING) EXISTING UNDERGROUND ¢I ^^" WATER MAN HOLE(EXISTING) HAND HOLE(PROPOSED)30X60X3D OVER HEAD GUY TELECOM MAN HOLE(EXISTING) FUTURE ROUTE 5 8 o HAND HOLE(EXISTING)24X36X24 u4/ M" POWER MAN HOLE(EXISTING) PROPOSED TRENCH Of ® o HAND HOLE(PROPOSED)24X36X24 PROPOSED BORE 0 POWER POLE WITH ATTACHMENT(EXISTING) W ® 4p FIRE HYDRANT(EXISTING) -R[W- RIGHT OF WAY j p o POWER POLE NO ATTACHMENT(EXISTING) CENTER LINE OF ROAD ® CABINET STRUCTURE(EXISTING) Lu mF o STREET LIGHT POLE(EXISTING) EOP EDGE OF PAVEMENT o Z z x M CAUTION SIGN FOR CROSSING (EXISTING) d O o w a C&G CURB AND GUTTER E- L8 w o a POWER HAND HOLE(EXISTING) U U V Z z P CL= AERIAL CLEARANCE QF FIBER MARKER U g z a =� TELECOM PEDESTAL(EXISTING) ® BORE PIT SAN SIDEWALK N m N DWY DRIVEWAY F- o ® STORM DRAIN GRATE(EXISTING) POT HOLE w e VALVE U EXISTING TREE(SIGNIFICANT) Q ® STORM DRAIN o EXISTING UTILITY HAND HOLE DATE 4/17/19 END OF CABLE SPLICE CLOSURE(PROPOSED) ENGINEER ors ❑ SILT FENCE DRAWN By MPS F` BUTT SPLICE CLOSURE WITH ATTRIBUTES REVISIONS ^' MID STRIP SPLICE CLOSURE WITH ATTRIBUTES QA,� ENVIRONMENT CHANGE TELCO OWNED POLE(EXISTING) TELCO OWNED POLE WITH ATTACHMENT(EXISTING) r. wSCALE�^ HORIZONTAL 1:30 SHEET 12 OF 27 NFID 1710AICP_4 FONID- N RTH NOTE:CAUTION GAS IN AREA Yef onbusinm PROJECT 074664 NOTE:CONTRACTOR TO LOCATE 1 ALL EXISTING UTILITIES. NOTE:CONTRACTOR TO FOLLOW FDOT 602&660 TRAFFIC CONTROL PLAN ON PAGES 26&27 / / k d NOTE: TO BE APPLIED FOR IN SEPARATE PERMIT: / Q JAX_1710AICP 5 RT FDOT_MAYPORT RD 1 ; � a • C PLACE 1-2"HDPE SDR11 W (\ BORE PIT#1 VIA DIRECTIONAL DRILL W NOTE: 4'X4 REPAIR ANDAND PULL 432F THROUGH j a o Ld'_ 1 RESTORATION REQUIRED: CONDUIT L) W wP Rp / oo+se y r oU �$ N U n F4 E 0 w Pjw 0 U tNq z '1: w o SILT FENCE DWY _ r ---o OWY R v RM = Z _ w a �- m D - m o m CD / / o °} r o A U N� CD N up U � N Ct _gyp / p + C7 r42 PLAZA RD DATE 4/17119 ENGINEER OTS DWY DRAWN BY' MPS �� REVISIONS ----__ RnvDWyaiwBCALE HORIZONTAL: 1:30 SHEET 13 OF 27 NFID 1710AICP_4 "' --- FONID- m �a id AT l _ T� k k V, i a �/ !T. Ar _ N1111TH NOTE:CAUTION GAS IN AREA ' ~170nbusiness NOTE:CONTRACTOR TO LOCATE ° / aRo ecT o74es4 ALL EXISTING UTILITIES. NOTE:CONTRACTOR TO FOLLOW FDOT 601&660 TRAFFIC CONTROL PLAN ON PAGES 25&27 I a I BORE PIT#2 I NOTE: 4'X4 REPAIR AND a RESTORATION REQUIRED: PLACE 1-2"HDPE SDR11 04+11 VIA DIRECTIONAL DRILL _ AND PULL 432F THROUGH D CONDUIT .Ir T00 � BORE PIT#3 U) m NOTE: 4'X4 REPAIR AND W _ RESTORATION REQUIRED U z 07+65 L) n C7 w rtm_ �` s SILT FENCE Z v S — --- "M' N z r m Q __ M E 04 Al L) D V D z O w mm VV/ g =� RM +:; o DVVY Z o �w m F- 0 o a�n cL ci _� o L7 y o C� c o Cl — o o U PLAZA RD M 0 v —+ a + , RM1V R/VI anv� OA7E. 4117/19 RW��Rnv ENGINEER. OTS Rft RAV RAv DRAWN BY MPS aw RM, REVISIONS a� R iNlui. RA4 RAY RAY OWO SCALE Q HORIZONTAL 1.30 SHEET 14 OF 27 . NFID: 1710AICP_4 FONID:— _ P' s Cj 1 qhbJ . E! s , J NOR NOTE:CONTRACTOR TO LOCATE ® �-Zqmmhm ALL EXISTING UTILITIES. PROJECT:074684 NOTE:CONTRACTOR TO FOLLOW FDOT 601&660 TRAFFIC CONTROL 2=" PLAN ON PAGES 25&27 �a PLACE 1-2"HDPE SDR11 BORE PIT#4 p VIA DIRECTIONAL DRILL NOTE: 4'X4 REPAIR AND O AND PULL 432F THROUGH RESTORATION REQUIRED: W CONDUIT 11+13 U o M Rnr SILT FENCE W 8 Rnv S/W "M— mw o N ~ y U C3 © WY row SI R" my N_ i D E U) �1� O Irw 2 y `/ W o y ZZ ion N y o N = R 5 n o cLton m ~ O o cl �+ ai Q P + 01 U LAZA RD -° =—a o 00 Q o n +�a'N — a M— + CL CL--OpL Cj ' DATE'. 4/17/18 RAW ENGINEER: OTS pp n/w env DRAWN MPS RE £ a REVISIONS - 11yy RIW ) RhY I I owv I I c I SCALE n HORIZONTAL 1:30 I - SHEET 15 OF 27 NFID- 1710AICP 4 FONID— 1 C%D l 19 T 3 tu s n .. r e# W !,� ter, w, � y i b .. N RTH NOTE:CONTRACTOR TO LOCATE veriZonbus6,ess ALL EXISTING UTILITIES. PROJECT 074— NOTE:CONTRACTOR TO FOLLOW , FDOT 601&660 TRAFFIC CONTROL PLAN ON PAGES 25&27 E e PLACE 1-2"HDPE SDR 11 HH#1 F VIA DIRECTIONAL DRILL PLACE 30"X60"X30" SILT FENCE it AND PULL 432F THROUGH HAND HOLE AND O CONDUIT FIBER MARKER PLACE 1-2"HDPE SDR 11 U 14+33 VIA DIRECTIONAL DRILL W RN AND PULL 432F THROUGH U z 0 ww ww CONDUIT >cr F vv� Lu F� RAV Ri1V so 50 r. � O • RAV D ~O yn 01 O uYl F RAV o — WY 6 •• w - p RAv = U K W P/W Z 0, o - ---- DWY g z DWY m W w o +— �- 1 q p PLAZA RD N-00-._ u, 0) IL Q m R^• yA. Rtiv DWY DATE. 4117118 Rnv ENGINEERS OTS RAy ww DRAWN BY. MPS DWY � � � � REVISIONS RAV RIW p I DVN I � DwY � - - - DwY �JSCALE ,. IDWY HORIZONTAL. 1:30 I x I SHEET 1S OF 27 NFID 1710AICP 4 FONID- la K � M � " 1 _ i y i _ r r tw TIM �t - -- 64IFr ME ' r a r r � N RTH NOTE:CONTRACTOR TO LOCATE \YI16usiness ALL EXISTING UTILITIES. PROIECT:114664 NOTE:CONTRACTOR TO FOLLOW FDOT 601&660 TRAFFIC CONTROL Aar' PLAN ON PAGES 25&27 BORE PIT#5 5 NOTE: 4'X4 REPAIR AND (L RESTORATION REQUIRED: U SILT FENCE 17+80 PLACE 1-2"HDPE SDR 11 VIA DIRECTIONAL DRILL w ww iv AND PULL 432F THROUGH U z Rwg D ww j N CONDUIT x F N J!VYuj _ — DWY o 8 r Z N U n atv ww ro Q O w c� S/W ww ww ww n E N O _ 0 co ~ ww cl) f a �� -.. _ to w o IM « O DWY --+a �.� o o W PLAZA RD c. " �,+ O wv N o a Rw RI Rnv RU wy WY DATE. 4/17/18 ROW wW RAM WY ENGINEER OTS R4+' RI DRAWN BY MPS Riw �wW REVISIONS RlW—� LRW R" W SCALE HORIZONTAL. 1:30 SHEET 17 OF 27 NFID. 1710AICP 4 FONID- J1�c�Zb bd SWldd ldl.OL1 r ov 0w Alf r S N. � � �, � R � •lis Wr Oo cn Cn jo jr V j 1 , _ ,pr , < f3, i' I !1� N t.. J6 YA Aw s 0 v f 5 Y f • M r ..,n `w ao N ,. v v .1 J 7 y. .r J Ads t � p D y ' w ,• r' r Cp k• 'j m AMP— O NORTH I NOTE:CONTRACTOR TO LOCATE I Veri7onbusiness ALL EXISTING UTILITIES. � D � PROJECT.074664 NOTE:CONTRACTOR TO FOLLOW I FDOT 601&660 TRAFFIC CONTROL PLAN ON PAGES 25&27 BORE PIT#6 NOTE: 4'X4 REPAIR AND rn RESTORATION REQUIRED: I II c s PLACE 1-2"HDPE SDR11 I g 21+24 _ VIA DIRECTIONAL DRILL # AND PULL 432F THROUGH SILT FENCE a SILT FENCE CONDUIT BORE PIT#7 NOTE: 4'X4 REPAIR AND nnv M, Z DWYRESTORATION REQUIRED: "W ww 1N 25+07 if ww N I O lvw S!W DWY "^1 ww • G RNV Rw R.w m V Z 0 �_. __..—._ WY m W rn. ci. O - _ O • m (A ss a n o 0 1 2 Z �_N .M v R N CL _ O S 8/O_ +� N N a a o—�j—ci U07 E O V W PLAZA RD N -� -+ Z 2 Z O a CV N _ ��tt_.���.� O m DWY ww DWY F- R" ww vilyI DWY N RW ww ww row PJW �^ Q Fl" R V RhV DATE. 4/17/18 ENGINEERS OTS a DRAWN BY. MPS I m _ REVISIONS U) a E ;WY - SCALE. HORIZONTAL. 1:30 5 SHEET 18 OF 27 NFID1710AICP_4 FONID- BONITA RD '� `� s; F 41 MH-A-684 647 630 ILI [J 700 ~ rn v. 631, u 715 ,. 645 r d xj, r IT _Aim 31 WINxi ?* PLAZA �x ES Y �G �2 t g�. e� 690 a 670 - Alm 715 70 a , NORTH NOTE:CONTRACTOR TO LOCATE ver►Lonbusin ew ALL EXISTING UTILITIES. I PROJECT 074664 NOTE:CONTRACTOR TO FOLLOW FDOT 601&660 TRAFFIC CONTROL C� R� PLAN ON PAGES 25&27 I I $ B PLACE 1-2"HDPE SDR11 5 I I VIA DIRECTIONAL DRILL AND PULL 432F THROUGH , I r I HH#2 CONDUIT rt m PLACE 30"X60"X30" I PLACE 1-2"HDPE SDR11 HAND HOLE AND —FIBER MARKER I Z VIA DIRECTIONAL DRILL 29+10 = F I AND PULL 432F THROUGH U) �p CONDUITj ww m of m O R1 RW 7s/—vv s W01 1-3 V 2HryarN- .---- —��EOPllp EGF'� GL-_ ��' Z YUY _ S(W — O EOP��� °°T c -o'- PL -�`�D V N / ,n1r w ui __.----- CF ��E��- Co i u-f})� �\//'I DWY Eo= El ci��p � D f m x 0. O OfZ �I (J c.rn- a DWY F N O Rm 0.N+ N _� W R- DWY aM, ^ �— DATE. 4/17/19 aN+ ' RM' R.� ENGINEER: QTS 4 DRAWN BY. MPS Z •I REVISIONS Z ' Dvvy - I r . 03 _ I I IecSCALE �E HORIZONTAL'. 1:30 I SHEET 19 OF 27 NFID- 1710AICP 4 FONID- r' — a _ Or f Ilk w 3 _____..__ . - fig► / G z � + R d •• i I � NOR Val NOTE:CONTRACTOR TO LOCATE ALL EXISTING UTILITIES. . PROJECT 074164 NOTE:CONTRACTOR TO FOLLOW FDOT 601&660 TRAFFIC CONTROLxa PLAN ON PAGES 25&27 PLACE 1-2"HDPE SDR11 VIA DIRECTIONAL DRILL BORE PIT#8 AND PULL 432F THROUGH NOTE: 4'X4 REPAIR AND CONDUIT y " 3 RESTORATION REQUIRED: 32+57 SILT FENCE _ F LLa Rte+ _ RNA RN m O w (a1 PM RNA i/ _ -.._.._�`,_ N V 2 p Rw--.�RIM EOP N srW EfjP-- � f 8 - RM R- MM _ .. EDP EOP�� ECR Q U Z z O Qn RlN sop�- W GL,GL -� E N U W C7 EOP _ �EOP W 0 PLAZA R� EOP E�—£ z +-LL a 2 Z -EOP £GP fOP l O--G �-Cl O ECP EOP ZZ( N N S ECA �+ ` ID EOP Y. r eap to Do -� COP-WO ` GL 4•CL p �.i fT O EW EOP 5 O 1p RA a +—a 1,L–+— S am-- �RM U o DWY I Rrr UQ WY RIW _ DATE. 4117118 ENGINEER: OTS LAµ —RNI DRAWN BY MPS -�R. REVISION' SCALE.. HORIZONTAL. 1:30 SHEET 20 OF 27 NFID: 1710AICP 4 FONID- s ' fes' £ •i:^ (r .{� 4 1 ; . y E ��y�,�� • m• a: .r , i sot VAC 4*� Y , , ' MATCH SHEET-22 NOR ` RMS� NOTE:CONTRACTOR TO LOCATE RM V9IIL0�lbusiness ALL EXISTING UTILITIES. L2' PROJECT 074664 NOTE:CONTRACTOR TO FOLLOW 17' FOOT 601&660 TRAFFIC CONTROL 66' I L1.W PLAN ON PAGES 25&27 1+00 I 42 HH#3 PLACE 1-2"HDPE SDR11 W PLACE 30"X60"X30" , BORE PIT#9 _ VIA DIRECTIONAL DRILL HAND HOLE AND NOTE 4'X4 REPAIR AND AND PULL 432F THROUGH I co) FIBER MARKER RESTORATION REQUIRED: CONDUIT Y I 37+34 36+05 Q 00+ 013' SILT FENCE Rw SILT FENCE F w Q N RM1 RN V RM siv, SIW EGP W F pp^ —PIM RM1 • I WL-�-CL CL Lu ] y< RIM — E�-�E� W .��qn+oo--" o PLAZA,RD Z y�y QQ int Eop EOPW +'l O EOP 0)O O W(0 SEOP'N —E E� CL—LL fl Ll EOP EOP�� — U� O 0V W EOP EGP (P� N—NL—O OFOP EO EOP _ a � EOP LL a ECP n N Pop� 0. u y E0. R/N +L ��EOP RrM F O Eop EoP PM' EoP RN1 RIM RIM LuV �RIM —PJ Q RIM �PIlI ��RIM� DATE. 4/17/18 —RM RMI pm OTS DRAWN BY MPS REVISIONS SCALE HORIZONTAL. 1:30 SHEET21 OF 27 NFID-. 1710AICP 4 FONID- lr�u ti r • 3 syr`f F'* da �I � �.�•^.. � ,.. , fix _ f 1 wkn ® A , w 1 e .„ Y.., z s AD Li LA WOW lie ,c ol - l Oji , R. �., .b, � ��'it� -,,,,«•�- ..._1� yy � -, ' MATCH SHEET-23 NORTH V NOTE:CONTRACTOR TO LOCATE \ \ ALL EXISTING UTILITIES. ® ; PROJECT 074664 NOTE:CONTRACTOR TO FOLLOW FDOT 601 TRAFFIC CONTROL PLAN ON PAGES 25 .� OQ+00 \ \ � 4 SILT FENCE II s CL 03+50 �0 O BORE PIT#10 y r NOTE: 4'X4 REPAIR AND U I RESTORATION REQUIRED. Zp o 03+50 � P I W N r U) r ¢ pZ i p8 17' ro O 0 03;00 2' U N i v w z PLACE 1-2"HDPE SDR11 Z o o N & VIA DIRECTIONAL DRILL F 24 AND PULL 432F THROUGH o CONDUIT w 55' U I Q 02+50 1 DATE 4/17/18 f ENGINEER OTS \ DRAWN BY MPS p REVISIONS �RM \ _ -aN D1NY _ arN [caooe.xi:° u SCALE R. CIRCLE HORIZONTAL 1:30 SELVA LAKES o1+50 1 SHEET 22 OF 27 Rny NFIP 1710AICP_4 FONIP- , .. up zv- • t� T 1 'o 1v , j 4 MATCH SHEET-24 NORTH I /1�1 ve�- onbWmw NOTE:CONTRACTOR TO LOCATE : ALL EXISTING UTILITIES. 07 NOTE:CONTRACTOR TO FOLLOW +50 'u,11FCT074664 FDOT 601 TRAFFIC CONTROL PLAN ON PAGES 25 5 07"00 s F I �a SILT FENCE Q 27,� U U) w 06+50 BORE PIT#11 j o NOTE: 4'X4 REPAIR ANDW F I RESTORATION REQUIRED: W E r S I 06+60 CD O_ o O w(7 EIA r uw 22_ W PLACE 1-2"HDPE SDR11 Z o_ VIA DIRECTIONAL DRILL y Cr 06 i 0 AND PULL 432F THROUGH o 0 CONDUIT y � v � Q DATE. 4/17/19 \ \ ENGINEER OTS nrH DRAWN BY MPS Q/j\a P4 REVISIONS I psPREY \ o�xoo \ .�... SCALE« p \ HORIZONTAL 1'.30 \ a ¢N y_ SHEET 23 OF 27 4 NFID 1710AICP- 4 4 FONID- t � 1 d , 14 ♦ // T La Irw++ i 1 - v ®a wo y... / A� • �,y'.• �.,�: �y.F x'.53 y� _ t _ <x 6. p 1 / I I r " H / NOR v NOTE:CONTRACTOR TO LOCATE VerI70nbusiness£ � ALL EXISTING UTILITIES. N NOTE:CONTRACTOR TO FOLLOW p BORE PIT#12 FDOT 601&602 TRAFFIC CONTROL s 1 i 0 NOTE: 4'X4 REPAIR AND PLAN ON PAGES 25&26 103 2g RESTORATION REQUIRED: HH#4 10+00 PLACE 30"X60"X30" 71' kk NOTE: TO BE APPLIED HAND HOLE AND n�+ m FOR IN SEPARATE PERMIT i FIBER MARKER DAlY SILT FENCE XXXXXXXXXXXXXX 01+55 n Ep E EAP S SILT FENCE 11TH ST 11TH ST __ o EOP Oi;!— �— W•+��GC�— O µ Rf.N Rw (n O V• CL +'� O n^ a w 2 cO EW L F O N EOP pry/ PA's O z Z 8 - �Z Rw E� a 1�� Rw I 2' U/n z ow 96 I I Z 25' F o I I 0) w w U U 64 Q T I DATE 4117119 DV ENGINEER OTS r DRAWN BY MPS REVISIONS ltw 08+50 nrM 0 PLACE 1-2"HDPE SDR11 pm- m e \_ VIA DIRECTIONAL DRILL p AND PULL 432F THROUGH DWY o I CONDUIT SELVA LAKES CIRCLE [ SCALE N• '(Ul7 HORIZONTAL1:30 SHEET 24 OF 27 aM' / NFID 1710AICP 4 FONID'.— r lit PORK SIDE D �, � •- l_INKSIDE DF. . s + • d }I A a t/ oc low r" L) t vs�slness PROJECT.074664 _ ua b � O I- a BehrnO an Prrsuno carr/.., W o rWltn DIMrt1.1 0, 0M7 the ot!0q!of F WMk A.ld r.1S r rot.!from t !0I tf wlY O0_ o W � < O ~ Z y U 7 N Q O W U ! E, A. U CO zm z a =a Z o �� H O w W U GENERAL NOTES Q 1.If the work operation fercludinq esta6lrshing and terminating the work a eal /'equines that two or n,on work vehicles s t Ife of/set I—rn any one Mur. I raffic control will he rnconformance with Inter 101-601. p DATE 4117/18 1.No special sign is required. ENGINEER QTS 3.WMn a side road iNelsects the hrgnwav within tot work area.McH,onal TIC DRAWN BY MPS devices shall be Placed M accordance with other applicable TCZ IMekes. REVISIONS SYMBOLS 4.WMn const—t—act...Hes encroach on a sidewalk.ere.to Inde,.102-660. CONDITIONS ® Work Area S.For general TCZ requnrements and dddglonal infOrmall.n,refer 10 Inde.101-600, WHERE ANY VEHICLE.ACTIVITIES CTII ITIES WORKERS AND THEIR ACTNRIES b Lane Iderdiflcation+Direction of Traffic ARE BEHIND AN EXISTING BARRIER, NORE THAN 1BEHIND THE CURB, OR IS-OR MORE FROM THE EDGE F OF TRAVEL WAY. - - - R SCALE . HORIZONTAL 1:30 LAST O2 DE5CRIPTION: FY 20I9-20 INDEX SHEET REVISION FDO FTWO-LANE, TWO-WAY, WORK OUTSIDE SHOULDER 11/01/17 �� STANDARD PLANS 102-601 1 Of 1 SHEET zS oC v NFID. 1710AICP 4 FONID'— imanbusirmss PROJECT 11434 ROAD WORK N END AHEAD 55 J ROAD WORK A s25 a a A — CI 11 as 11 ■ 11111111 . 1111 . . . IL _ a as B raper Letprh 1,11. wort Area �i O -- See rabic Table 11 N ROAD WORK W RonD Taper Length- Shoulder WORK Devtre 5 , raper Dentes t nt SBO U Z • see vele I se.Tabro r Y,t(it) o $N AHEAD,+- pileal SMZDIKw Flats Smphl C h7 11 Motes W j r e eY[M a[.f SMdr. S. S.1 PJts(Yf 1111 15 111 35 12 Oz 0 V g Table 1 30 40 50 60 L-WS, ro 0 Device S Cing _ 35 ss se 112 E N Ir w ----.I.—.11__11 MeK.Distenre eerween devices pt) 40 71 90 107 6 on 7j Speed Cones or TYpa I or Type/l /S 120 150 1110 ((� LU =Tjj earnceees or vernraf 11_11_--.__—_. 1111.. w o DISTANCE BETWEEN SIGNS (mph) Tubular Mertes so 133 167 zoo Z o N Panty Drums ...._....1111 1111..... m SpKirq(rt.) Taper Tetspent Taper T ngen( 55 117 I83 220 F- n Sged A 11 25 75 SO 25 - 501111 60 160 200 240 L-WS F- 0 1111....—_.....___...._ _1111..... 1111_. b m A or less 200 200 30 to 45 75 30 30 SO -�- 65 173 2" 160 (1)45 mph 370 350 70 1117 233 +2110. 50 mph or renter SOO _S00 50 to 70 75 50 SO 100 V 'Mto."",We-signs. 9 minimum shudder width (� Q qrL- Length of slldulhar taper in feet SYMBOLS GENERAL NOTES DURATION NOTES W- Width of total shoulder,n reef DATE. 4/17/18 (combined paved and unpaved width) Wort Area I.Wren four or more wort vehicles enter the through traffic Mod,in a one hau L Signs and cnamWl¢mg OevrtDs mar be p 111 d It aR or Inc ENGINEER- OTS period or less(extruding establishing and ter-rat tarp the work areal the ini—ed totlowinq WnORiom are men 5- Posted spead none(mph) DRAWN BY MPS FLAG6FR sign shall be substituted for he WORKERS sign For)oration o/flaggers a.Work operations are 60 minutes or less. Channeh:ing Device(See Intek 102-600) and FLA6GER signs.see Index 102-603. u.Vehicles in the work area have high-intensity,rorahng, REVISIONS flashing,oscillating,or stroll lights operating. Work Zone Sign 2.SNOULDEA WORK sign may he used as an alternate to the WORKER svmool 5,91 only - - - M the side where the shoulder work is being performed. b Lane Identification+Dir—kin of Traffic - - - 3.When a tide road Intersertz the highway within the TTC IorW,a001rloNl TiC devices shah be placed In acco,dence with finer applicable TCZ Indexes - - CONDITIONS - - - 4.For general TCZ ceguiremeMs eat additional,n/ormation,r.far ro Index 102-600 - - - WHERE ANY VEHICLE.EQUIPMENT, 3 WORKERS OR THEIR ACTIVITIES - 6 ENCROACH THE AREA CLOSER u THAN 15'BUT NOT CLOSER THAN Z TO THE EDGE OF TRAVEL WAY. a SCALE . HORIZONTAL'. 1:30 LAST 2O DESCRIPTION: FY 2O79-ZO INOEK SHEET REVISION q FDOT� TWO-LANE, TWO-WAY, WORK ON SHOULDER 17/01/17 �' STANDARD PLANS 102-602 1 Of 1 SHEET 26 OF 27 II 1710AICP 4 Y6f1�T,9nbusiness PROJECT 074664 GENERAL NOTES: SYMBOLS ® Wort Aree 1.Wnhen e—dachi,q—k requires a sidewalk Closure for 60 6.Provide a cross-slope ,In a 10-1 value o/0.02 for all temporary walkways. mules or greater,provide an alternate pedestrian route. • Channeh-9 Device 7,Mandan.temporary walkway surfates no ramps that are sl able,firm,slip-resislare, Wort zone 5ign 2.For spa[aq of vehicular Channeiirinq Devices,see applicable and free of any obstructions or har'a/ds such as holes,debris,mud.construction pp D' vehicular temporary traffic COMr01 Inde-S. equipment.and stored material. N CR Required Locations For Either Temporary 3.Cover or deactivate pelest/ran traffic Signal dns la SJ controlling R.Romove temporal Ikwa s immedtstely after rpo f the sidewalk,unless NJ 0/Permanent Curb RemOs. ph P W 4 Y wt Y penin9 o g [IOSM crosswslks. nrherwise nwed in the plans. g b Lane Identifi[atlon♦Dlreclion of Traffic y 4.For post houMed signs located near or adjacent to a sid—A 9.Meer the req.kenrenr,of Inde.522-002 for temporary curb ramps. Pedestrian Longitudinal Channeara Devrke(LCOS ivied 6 l� n9n g maintain a mininxrm 7'Clearenrc from the bottom of the.sign r Mounted Work Zane Sign or separate Work Zone Sign panel to the surface of the sidewalk. 10.Place pedestrian longitudinal channeh—g deyicMsl across the full width of the 8 s E H Pedestrian Longitudlnat Channellking Devnte(LCD) Closed sidewalk.For temporary walkways.similar to the Sidewalk Diversion. N ® 5.Provide a 5' imowide temporary walkway except where space restr,11—s place LCDs to dehneate both.sides of the temporary walkway. Temporary Sidewalk a ant a m l ,width of P.Provide a 5'r 5'passing space for temporary walkways less than S'rn width at intervals not to I1.For sidewalk diversions,ensure that there is sufficient R/W for placement of er[eed 200' temporary S,d—kk and pedestrian longrtudrnal rhaf-n dhires d�4 0 W U Z j o 0 � F r - W In Fo a CR y U n b Z / ��✓/ Uw z Uw = C0 ga ���iETw1R�� "'www"'IIIw o —' 03SOTJMIVM3O15 �81 Z O �y III..RRC��'eej+ x'30 F on 0 0 4 NIVMMISU J o dj Row 03SOlD Co I W 7 ?, SIDEWALK 3 DATE 4/17/19 _ CLOSED re9ol evt -�- de• WAUMY r ENGINEER: OTS I DRAWN ev. MPS REVISIONS r Q� .— otre pescmmor. rams USE OTIIEfl 510E / T II 4 CR 1 VV Rp1D b14 b�4 R Ak1EA0 u CROSSWALK CLOSURE AND SIDEWALK DETOUR SIDEWALK DIVERSION x PEDESTRIAN DETOUR SCALE OESCRIPTION� HORIZONTAL. 1:30 h REVISION l.tST FY 2019-20 INDEX SHEET 11101/17 F � STANDARD PLANS PEDESTRIAN CONTROL FOR CLOSURE OF SIDEWALKS SHEET 27 OF s7 102-660 lof] NFID- 1710AICP 4 FONID.—