Loading...
1912 N Sherry Dr ROOF19-0063 Metal, 2nd Story ROOF NON SHINGLE PERMIT PERMIT NUMBER r s ROOF19-0063 CITY OF ATLANTIC BEACH � 800 SEMINOLE ROAD ISSUED: 7/18/2019 ATLANTIC BEACH. FL 32233 EXPIRES: 1/14/2020 MUST CALL INSPECTION • • • 1247-5814 BY 4 PM FOR + INSPECTION. ALL • ' K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' D+ BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: metal roof for residential 1912 N SHERRY DR ROOF NON SHINGLE addition & 2nd story $5000.00 addition TYPE OF • • GROUP: 172020 0826 SELVA MARINA UNIT 10C COMPANY: ADDRESS: Planet Roofing 100 N. Federal Hiwy Ft. Lauderdale FL 33301 �•�® ADDRESS: CITY: STATE: KABLAWI RAWAN 1912 SHERRY DR N ATLANTIC BEACH FL 32233-4520 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF • • • Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 45S-0000-322-1000 0 $80.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 4SS-0000-208-0600 0 $2.00 Issued Date:7/18/2019 1 of 2 yLi City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road '`� l !.1 ' o V 1 Atlantic Beach, Florida 32233-5445 V S Phone(904)247-5826 • Fax(904)247-5845 9' E-mail: building-dept@coab.us Date routed: L City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: tl Department review required Yes No Applicant: [)(A Planning &Zoning Tree Administrator Project: J*(\ 0 0 Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. [—]Denied. ❑Not applicable (Circle one.) Comments: PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. []Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/1912017 Wd8S : LBuilding Permit Application Updated l0/9/18 Z��z City of Atlantic Beach Building Departme � **ALL INFORMATION a V 800 Seminole Road, Atlantic Beach;fl 32233 HIGHLIGHTED IN GRAY UA IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us �5 REs iq- 0,10G Job Address: I L l /� 7l L(� Permit Number: �VOF� ct _00 �J Legal Description 37- - v2 — c-I t/ iT -C RE# C)a-�C 0t,�2 6w!& cTIL Valuation of Work (Replacement Cost) $ L" Heated/Cooled SF Non-Heated/Cooled • Class of Work:�ew 1,ddition ❑Alteration ❑Repair ❑Move []Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): OSammercial Pkesidential u 1, i__ICE COPY • If an existing sfticur ,"fire sprinkler system installed?: ❑Yes fkN0 • Will trees be removed in association with RroDosed roiect? LJYes must submit separate Tree Removal Permit No Describe in detail the type of wor to l�e per€ifled: Florida Product Approval# ! 5 for multiple products use product approval form Property Owner Information -� Name Address Z Z2y n2. A:B City State_I-- Zip 3 ZZ� 3 _Phone z-b 1-7 ?`/ — E-Mail _ Owner or Agent(If Agent, Pow6r of Attorney or Agency Letter Required) Contractor Information Name of Company I Lv}ij�_ x7F IQualifying Agent c-iL43.4-- Address +" N f-6I tflti City Ui-+ Ilu- tate Irk Zip 1;V) I Office Phone �-'I' 2✓i�- vlt"}. Job Site Contact Number State Certification/Registration# CCL E-Mail _40,0,-1 L - (. I Architect Name& Phone# f✓A- UJI Engineer's Name& Phone# f\/Fr Workers Compensation Insurer OR Exempt Expiration Date N Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installoTho Z commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws reg tkg Z h'- N construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,S{3NW , Z w WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE: In addition to the requiremera Nt&® Q permit,there may be additional restrictions applicable to this property that may be found in the public records of this couly 6. O there may be additional permits required from other governmental entities such as water management districts, state ageeMi;- (W Z federal agencies. U � 0 y OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance web io � Z applicable laws regulating construction and zoning. LL. cc s WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT M@Y� w w a. cr m RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU IIN w W TO OBTAIN MKtNG, C ULT WITH YOUR LENDER OR AN ATTORNEY BEFORE W ¢ w RECOR C MENCEMENT. s ix �i�ature o O r or Agent) I (Signature of Contractor) Signed and sworn to(or affirmed) before me this_LL day of Signed and worn to(or affirmed)before me this day of 'I LA,k�A Ok by ti USS t�A 2 by P14�) C l 3i s± n tary) P JOHNSTON " ?ota WE JENNIFER 8mded' Oja(Y MY COMMISSION#GG 042984 (Ll Personally Known * o' EXPIRES:October 27.2020 Personally Known OR :9 Produced Identific ofr. p. Fo;t;: BondedThmNotary Public Undemriters [ ] produced Identification ( J i .,..,.. Tvpe of Identification: Type of Identification: PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH FLORIDA (*REQUIRED) jj Ic-� � *Project Address: IK L ( ZZ Permit#: OQ F'l of --0063 1 4- *Owner/Project Name: ( Syl As required by Florida Statute 553.842 and Florida Administrative Code Rule 913-72, please provide the information and product approval number(s)for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B. WINDOWS 1. Single hung j 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 1 of 4 Updated 10117118 U�M;t Wry Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wali louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1.Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal, 1� � � Z 31L, roof Lt I, 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14.Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 10117118 UWUL WHY In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name): i� ''7 lit *Contractor Signature: *Company Name: *Mailing Address: 00 7--) - u *City: -12,� L-AZocv2nfk-.f *State: � *Zip Code: *Telephone Number: �— ,�-�;,�( 1 '� *E-mail Address: { V co 41 Cell Phone Number: Fax Number: Page 4 of 4 Updated 10/17/18 OFFICE COPY Gulfcad�t. . , . . . . , SUPPLY & MANUFACTURING TM LOK 26 GA. GULFLOK 16"WIDE RQ• i • • Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga. GulfLokTM 16" Wide Roof Panel over 15132" Plywood Florida Product Approval #11651.16 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. t%%I11110" 14429 SW 2nd Place, Suite G30 ;` tpN� �... Newberry, FL 32669 ''��GENS� *: No. 75519 Engineer Evaluator: Dan Kuhn, P.E. #75519 =-a- "�'• STATE OF Florida Evaluation ANE ID: 10743 :0, - . < %Fs•., "1/0 L ENG`D�05�201 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL#11651.16 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT KUHN ENGINEERING, OFFICP r0P 01,11, . . . • d 111441 WAJ21.01LIFITIGulfc6dft SUPPLY & MANUFACTURING TM LOK 26 GA. GULFLOK TIA 16"WIDE 7L, ROOF ' + • f • i Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfLokTM, 7/8" Nailstrip Roof Panel, Minimum 26 Ga. Steel, Maximum 16" Coverage, Roof panel restrained with fasteners into minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 16" Coverage Maximum Female Rib: 7/8" Tall Male Rib: 3/a" Tall Rib with Slotted Strip Panel Seam: Snap Lock Panel Clip: 24 Ga.Zinc Aluminum Coated Steel, 24" Long. Used at Corner Zones only, where required design pressures exceed-121.75 psf. Panel Fastener: Through Panel Slot: (1)#10-12x1" Pancake Type A 1/4" Minimum Penetration through Plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2017. Design Uplift Pressures: Table"A" Maximum Design Pressures Maximum Design Pressures -63.5 psf -121.75 psf -161 psf Sealant No Yes No *Design Pressure includes a Safety Factor=2.0. FL#11651.16 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT • ■ FLORIDA P . . , GullCoz st SUPPLY & MANUFACTURING TM LOK 26 GA. GULFLOKI" 16"WIDE ROOF PANEL OVER • • Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization#TST-5328) Report No. 117-0301T-10A-C, Dated 07/26/2013 2. TAS 125 Architectural Testing, Inc. (FBC Organization #TST-1527) Report No. B9000.01-450-18, Dated 12/122012 3. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519)@ Kuhn Engineering, LLC (FBC Organization#ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL#11651.16 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT W' FLORIDA PRODUCT APPROVAL ulf Goast SUPPLY & MANUFACTURING TM LOK 26 GA. GULFLOK 16"WIDE ROOF PANEL OVER • • >< Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.16 R3•OCTOBER 5,2017 PRODUCT , _ REPORT KUHN ENGINEERING, LLC 1200 CLINT MOORE • RATON, FL 33487- FL COA#30464 urrivar. euir ENGINEER'S LOAD TABLE SPEC GuIfCi6ast SUPPLY & MANUFACTURING TM LOK 26 GA. GULFLOK�` 16"WIDE ROOF PANEL OVER • • I ENGINEER LOAD TABLE: 26 Ga. GulfLokTM 16"Wide Roof Panel over 15/32" Plywood 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN.1/4" (MIN 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING 2Cf .,E„1 (1)f(1f1 11x1 D?C i (arfY AA A ArSEMBLY,A t SEM$fl A AS Iv#fil� A A tLl�ll)( .A r15� 'Y ZONE2 (1)#10-12x1” PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY B ASSEMBLY B 1.)PANEL DESCRIPTION:GULFLOKTM, MIN.26 GA, 7/8" RIB, 16" MAXIMUM COVERAGE,SNAP SEAM. 2.)PANEL FASTENER: TiHROUGH PANEL SLOT.(1)#10-12X1" PANCAKE TYPE A, 1/4" MIN. PENETRATION THROUGH PLYWOOD. 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-63.5 PSF AT 516"O.C.ASSEMBLY A,-121.75 PSF AT 51/s"O.C.WITH SEALANT ASSEMBLY B, -161 PSF AT 51/8"O.C.WITH CLIP ASSEMBLY C. PRESSURE BASED ON UL 580/UL 1897 TESTING BY FORCE ENGINEERING& TESTING. 4.)PLYWOOD DECKING:MIN.15/32" THICK,APA RATED PLYWOOD,GRADE C-D. MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017 5.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. Note:Dimension(a)is defined as 10%of the minimum width of the building or /,ZONE 2 HIP ROOF ZONE "a' 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be —,a less than either 4%of the minimum width of the building or 3 feet. ASSEMBLY A RIDGE i J - – – 16"COVERAGE ZONE i �� � - - - � #10-12 X tTYPE A PANCAKE SPACING:SEE UPLIFT TABLE E`VE ASSEMBLY B ZONE 2 GABLE ROS tea, 1/4'-5116-DIAMETER BEAD OF TITEBOND SEALANT—, -- -+a • ...._ ......_._..(1)#10-12 X 1'TYPE A PANCAKE _..... RIDGE SPACING:SEE UPLIFT TABLE ------ >----------------- —a ASSEMBLY C W/CLIP GuHLok"CUP 24 GA. —___ ZONE 1 _.-.. --. '•....•.- --_..-.(i)#10-12 X P TYPE A PANCAKE %, SPACING:SEE UPLIFT TABLE `-ZONE 3 ` EAVE FL# 11651.16 R3•OCTOBER 5,2017 PRODUCT REPORT ENGINEERING,KUHN Installation Storage and Handling Metal roofing panels are designed toshedwater,not to ho/d –Tarp water for an extended period of time.Thus,it is important to (loosely attached store panels dry—position a stack of panels away from standing x to permit airflow) water,elevate one end to allow water drainage,and cover loosely with a tarp as shown in the image.Storing panels under cover or indoors is recommended.Panels must NOT be stored in vicinity of:saltwater,corrosive chemicals,pressure treated Elevate end of panels lumber,fertilizer,or other chemicals.When handling panels,be sure to support the panel to avoid damage from bending of the panel.In general,no more than 1,13 of the length of a panel should be unsupported. Preparing the Roof Deck In most cases,the rafters or roof trusses will be covered with a sheathing material(plywood,OSB,etc.)which is then covered with underlayment.The design and construction of the roof structure and decking is outside the scope of this document.However,it is important to note that a poorly prepared roof deck will likely result in a poorly installed metal roof.The roof panels will generally match the shape of the roof deck—if there are ridges in the underlayment,uneven decking or other high areas,these imperfections will likely show through the metal panels. Order of Installation Typically,eave drip,valley trim,and transition trim are Measure one panel installed with the underlayment.Metal panels are installed width along ridge next.Finally, ridge/hip caps,gable trim,and end/side wall trim are installed last.(Note that not all trims will be required z in all cases.) Y J 4 S Installing Metal Panels Measure one panel Install the first panel with the overlap side along the gable. width along eave It is common to measure one panel width along the ridge and the eave,and to chalk a line between these points.(See images)Aligning the panel edge with this line will help set • - - E the first panel.It is extremely important to set the first Align first panel with chalk line panel square;any deviation will ripple across all of the E, remaining panels. ;�—Nail strip and/or male Typically,the first panel is attached on the gable end by ; ;; leg on field of roof driving fasteners through the panel directly to the deck. E EE (This portion of the panel is then covered with Z-flashing and Female leg on gable rake.)The other end of the panel will receive a clip or ; ;; gable end of roof will be fastened through the nail strip. E E� (888)393-03351 www.gulfcoastsupply.com Installin GulfLokTM sna lock, cli less system or nail strip) OFFICE COPY Installing ( P P Y P) Gulfl-ok°"installation begins as described above.The first panel is fastened to the gable end by driving fasteners through the panel near the female leg(opposite the nail strip edge).Next,the other side of the first panel is fastened through the nail strip.The next panel is snapped on by pressing the female leg of the next panel onto the male leg of the previous panel.Firm pressure is required to make this snap.The use of a white rubber mallet may be helpful but should be used with care.(Black rubber is more likely to mark the panels.)Once the panel is snapped,the opposite end is fastened through the nail strip.Continue this pattern across the roof section.Refer to the product approvals and the load tables in this document for fastener spacing and other special fastener requirements. The process of snapping and unsnapping the panels may cause permanent deformation of the outside edge of the female leg.It is recommended that the panels be snapped in place only one time.However,if the project requires it,the panels can typically be pried apart with a flat head screwdriver or claw hammer. Some installations require a Titebond sealant(or similar)in the seam.This provides extra watertightness performance,but also acts as an adhesive.The sealant should be applied to the inside of the peak of the female leg prior to installation of the panel.Once set,the panels may be very difficult to separate. Installing GulfSeamTM(snaplock,clip system) GulfSeam` installation begins as described above.The first panel is fastened to the gable end by driving fasteners through the panel near the female leg(opposite the nail strip edge).Next,the male rib on the other side of the first panel is held down with clips.The clips are fastened to the roof deck with two or more low profile/pancake fasteners.The female leg for the next panel is snapped onto the first panel,clips installed,next panel snapped,and so forth.Continue this pattern across the roof section.Refer to the product approvals and the load tables in this document for clip spacing. Installing VersaLocT"'and MegaLocTM(mechanical seam) VersaLocr"and Megal-oc"require the use of clips and special seaming tools.Typically,hand seamers are used to begin the seam,and a mechanical reamer can complete the seam.Gulf Coast is proud to partner with DI Seamers to provide mechanical seamers tailor built for Gulf Coast panels.Please see Appendix E for a copy of DI Seamer's instruction manual and see.httl2://ciulfcoastsupply.diroofseamers.com/for more information.Refer to the product approvals and the load tables in this document for fastener spacing Fastening Nailstrip Panels and Clips Correct installation of fasteners is critical to ensure performance of the roof.Overtightening can strip out the substrate,reducing the fastener pullout/withdrawal performance.Overtightening a nail strip panel can over- engage the panel and create a waviness the nail strip. Use drill/drivers,screw guns or similar tools with maximum RPM of 2,500.Depth-sensing nose pieces are recommended to ensure consistent tightening of fasteners.Impact drivers are not recommended as they may overdrive or damage the fastener. Install the number and spacing of clips and fasteners as required by the load tables contained in the product approvals and this document. Remove any metal shavings/fragments.Failure to brush off or otherwise remove all of these metal shavings will result in rusting. (888)393-0335 1 www.gulfcoastsupply.com A Field Cutting Metal Panels Tin snips or electric nibbler/shear tools are recommended for field cutting panels.Cutting a metal panel with any device will create small slivers of metal that must be removed from the panel to avoid rusting or damage to the panel.The use of circular saws or other abrasive cutting tools is not recommended as these tools will create significant heat which can burn the panel coating and may produce tiny,hot metal particles which can become embedded in the panel finish.Both of these conditions are likely to result in premature rust and corrosion of the panels. Care and Maintenance Gulf Coast Supply recommends that a metal roof be assessed annually to check for any damage or deterioration. This can be done from the ground in most cases(binoculars may be helpful).Consider visually assessing the following items: a. Look for water stains both outside and inside the building(if possible)that may indicate a leak. b. Check for missing,loose,or deteriorated fasteners.Thermal expansion and contraction of the metal, foot traffic,and wind-induced movement may back fasteners out or otherwise compromise the fastener performance.Overtightened/over torqued fasteners are especially susceptible to back out over time. Tighten or replace fasteners as needed. c. Assess condition of any visible sealant.Metal roof longevity studies indicate that sealants are often the first component to fail.Replace cracked or peeling sealant. Remove loose debris and clean the roof as needed.Mild biodegradable cleaners,household ammonia,or household bleach may be used when necessary(dilute V2 cup of 5%bleach in 1 gallon of water).Consult the warranty information or contact the manufacturer for more information on your specific system. (888)393-0335 1 www.gulfcoastsupply.com m