Loading...
1820 N Sherry Drive RESA18-0031 Manual Compliance * IINFORMATION Revision Request/Correction to Comments HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 c A (/�J AT" =�� _ GSA ' - v O2S - Phone: (904) 247-5826 Email: BuildlngDept@coab.us PERMIT C� Revision to Issued Permit OR ❑ Corrections to Comments Date:07'16 —cfO& Project Address: /?. Q SWefQ P V 22e � /'T19A#IC 19MC# ,�/ �233 Contractor/Contact Name: f} (�Q Ll�N fl��-��n� cmA 0/Q "R� Contact Phone: VV- �Y � —/d 12 Email: Description of Proposed Revision/Corrections: <1-::�' 1�4� e e car I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Will proposed revision/corrections add additional square footage to original submittal? Y❑No ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? b6No ❑*Yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments601)7t? �� �!�" a In g /? P ,gecl &1W rSy 3kPP4S So f'o cag/ De tment Review Required: Build, Planning&Zoning Rev ed By Tree Administrator Public Works Public Utilities Public Safety Date Fire Services Updated 10/17/18 REVISION Manual S Compliance Report BP# t2&S,�} j 003/ wrightsoft DATE `7 / / 'C, Master Area SIGNED !'r Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web.www.avalonac.00m License:CMC1249968 y 110 1 Project Information For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 14852 Btuh Entering coil DB: 76.5°F Outdoor design WB: 77.3°F Latent gain: 4753 Btuh Entering coil WB: 63.3°F Indoor design DB: 75.0°F Total gain: 19605 Btuh Indoor RH: 50% Estimated airflow: 780 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNF030L Actual airflow: 780 cfm Sensible capacity: 16380 Btuh 110%of load Latent capacity: 7020 Btuh 148%of load Total capacity: 23400 Btuh 119%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 31.8°F Heat loss: 6787 Btuh Entering coil DB: 69.2°F Indoor design DB: 70.07 Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNF030L Actual airflow: 780 cfm Output capacity: 24000 Btuh 354%of load Capacity balance: 1.7 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 780 cfm Output capacity: 0 kW 0%of load Temp.rise: 0 °F Meets all requirements ofACCA Manual S. wrightsoft" 2019-Jul-1117:16:12 ^C „, Right-Suite®Universal 2019 19.0.04 RSU23882 Page 1 ACcK ...rsWome\Dropbox\Duct Layouts\1820 Sherry BS.rup Calc=MJ8 Front Door faces:E Manual S Compliance Report Job: + Wrightsoft Date: Jul 11,2019 Upstairs Zone 1 By: Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:www.avalonac.00m License:CMC1249968 Project Information For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 25382 Btuh Entering coil DB: 78.4oF Outdoor design WB: 77XF Latent gain: 9352 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 34734 Btuh Indoor RH: 50% Estimated airflow: 1167 dm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HCB636A00310+FV4CNF002L Actual airflow: 1167 cfm Sensible capacity: 24500 Btuh 97%of load Latent capacity: 10500 Btuh 112%of load Total capacity: 35000 Btuh 101%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 31.8°F Heat loss: 21650 Btuh Entering coil DB: 68.9°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HCB636A00310+FV4CNF002L Actual airflow: 1167 cfm Output capacity: 35200 Btuh 163%of load Capacity balance: 19 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1167 cftn Output capacity: 5.4 kW 84%of load Temp.rise: 50 °F Meets all requirements ofACCA Manual S. wrightsoft- 2019Ju1-11 17:16:12 Right-Suite@ Universal 201919.0.04RSU23882 Page ACCA ...rsWome\Dropbox\Duct Layouts\1820 Sherry BS.rup Calc=MA Front Door faces:E Manual S Compliance Report Job: wrightsoft- Date: Jul 11,2019 Upstairs Zone 3 Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:www.avaIonac.com License:CMC1249968 Project • • For. Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.8'F Sensible gain: 12651 Btuh Entering coil DB: 77.6°F Outdoor design WB: 77.3°F Latent gain: 6384 Btuh Entering coil WB: 63.7°F Indoor design DB: 75.0°F Total gain: 19035 Btuh Indoor RH: 50% Estimated airflow: 780 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP024L Actual airflow: 780 cfm Sensible capacity: 17246 Btuh 136%of load Latent capacity: 4351 Btuh 68%of load Total capacity: 21596 Btuh 113%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 31.8°F Heat loss: 9915 Btuh Entering coil DB: 69.2°F Indoor design DB: 70.0'F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP024L Actual airflow: 780 cfm Output capacity: 18611 Btuh 188%of load Capacity balance: 11 'F Supplemental heat required: 0 Btuh Economic balance: -99 'F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 780 cfm Output capacity: 4.1 kW 142%of load Temp.rise: 50 'F Meets all requirements ofACCA Manual S. ' wrightsoft" 2019-Jul-1117:16:12 Right-Suite®Universal 2019 19.0.04 RSU23882 Page ACCK rsWome\Dropbox\DuctLayouts\1820 Sherry BS.rup Calc=MJ8 Front Door faces:E Pro ect Summa Joy: -�- wrightsoft' � � Date: Jul 11,2019 Master Area Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:wawavalonac.00m License:CMC1249968 Project Information For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Notes: Design Information Weather: Jacksonville,FL,US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 of Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 52 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 3887 Btuh Structure 11279 Btuh Ducts 2900 Btuh Ducts 3572 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 6787 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 14852 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3905 Btuh Ducts 848 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(fl=) 695 695 Equipment latent load 4753 Btuh Volume(ft) 6255 6255 Air changestbour 0.11 0.06 Equipment Total Load(Sen+Lat) 19605 Btuh Equiv.AVF(cfm) 11 6 Req.total capacity at 0.70 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154722 Coil FB4CNF030L AHRI ref 9154722 Efficiency 8.5 HSPF Efficiency 12.0 EER,14 SEER Heating input Sensible cooling 16380 Btuh Heating output 24000 Btuh @ 47-F Latent cooling 7020 Btuh Temperature rise 28 °F Total cooling 23400 Btuh Actual airflow 780 cfm Actual airflow 780 cfm Air flow factor 0.115 cfm/Btuh Air flow factor 0.053 cf-nBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.76 Capacity balance point=2°F Backup:n/a n/a Input=0 kW, Output=0 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigNtsoft ..• �•,,....,W,, Wght-Sui4e®Universa12019 19.0.04 RSU23882 2019-Jul-1117:16:12 Page 1 t \Dropbox\Duct Layouts\1820 Sherry BS.rup Calc=MA Front Door faces:E Project Summa Job: wrightsoft" � � Date: Jul 11,2019 Upstairs Zone 1 Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:www.avalonac.com License:CMC1249968 Project • • For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Notes: Design Information Weather: Jacksonville,FL,US Winter Design Conditions Summer Design Conditions Outside db 32 'F Outside db 93 °F Inside db 70 'F Inside db 75 'F Design TD 38 'F Design TD 18 'F Daily range M Relative humidity 50 % Moisture difference 52 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 15124 Btuh Structure 15725 Btuh Ducts 6526 Btuh Ducts 7950 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 21650 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25382 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 7479 Btuh Ducts 1873 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft) 1523 1523 Equipment latent load 9352 Btuh Volume(fP) 13707 13707 Air changes/hour 0.21 0.11 Equipment Total Load(Sen+Lat) 34734 Btuh Equiv.AVF(cfm) 47 25 Req.total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HCB636AO0310 Cond 25HCB636AO0310 AHRI ref 9156147 Coil FV4CNF002L AHRI ref 9156147 Efficiency 9 HSPF Efficiency 12.0 EER,16 SEER Heating input Sensible cooling 24500 Btuh Heating output 35200 Btuh @ 47-F Latent cooling 10500 Btuh Temperature rise 27 'F Total cooling 35000 Btuh Actual airflow 1167 cfm Actual airflow 1167 cfm Air flow factor 0.054 cfm/Btuh Air flow factor 0.049 cf-nBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.73 Capacity balance point=19'F Backup: Input=5 kW, Output=18266 Btuh,100AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr ghtso 2019-Jul-11 17:16:12 t Right-Suiba@ Universal 2019 19.0.04 RSU23882 Page t ...rsWome\Dro box0uc1 La uts\1820 Sherry BS.rup Calc=MJ8 Front Door faces:E Pro ect Summa Jam: wrightsoft` � � Date: Jul 11,lois Upstairs Zone 3 Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:ww.avaIonac.mm License.CMC1249968 Project • • For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Notes: Design Information Weather: Jacksonville,FL,US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 'F Inside db 75 °F Design TD 38 'F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 52 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 6628 Btuh Structure 7835 Btuh Ducts 3287 Btuh Ducts 4066 Btuh Central vent(0 Cfrn) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 751 Btuh Piping 0 Btuh Equipment load 9915 Btuh Use manufacturers data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12651 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 5466 Btuh Ducts 918 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 987 987 Equipment latent load 6384 Btuh Volume(fP) 8883 8883 Air changes/hour 0.23 0.12 Equipment Total Load(Sen+Lat) 19035 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154931 Coil FB4CNP024L AHRI ref 9154931 Efficiency 8.2 HSPF Efficiency 11.0 EER,14 SEER Heating input Sensible cooling 16380 Btuh Heating output 24000 Btuh @ 47-F Latent cooling 7020 Btuh Temperature rise 28 'F Total cooling 23400 Btuh Actual airflow 780 cfm Actual airflow 780 cfm Air flow factor 0.079 clmBtuh Air flow factor 0.066 cfmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.66 Capacity balance point=11 'F Backup: Input=4 kW, Output=14094Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C wrigFftsoft^ 2019-Jul-1117:16:12 «•: Right-Suite®Universal 2019 19.0.04 RSU23882 Page 3 ...1s\FIome0ropboADuct Layouts\1820 Sherry BS.rup Calc=MA Front Door faces:E N Level 1 121 ctm 7" L vil 121 cfm Master 7' 121 cfm 348<t, 6" .. 1167cfrn3dBch - _ 4' j c 1 335 cfm 16 cfm 12" 35 OrnMaster Bath 14° Laundry oset 2 6" Kitchen 32�irm frn 117 cfm pining Q L' 4,. 4 Mud R --10„ 16cfrn.. 6 uest Bath 14" 97 cfrn®97 clam 97 cfm 54 cfrr Entry/Stain x ii Garage Family Room 148 cfr 6" ..____.. Job#: Avalon Heating and Air Scale:1 :100 Performed for: Page 1 Course Contracting 3665 Spring Park Rd RightSuite®Universal 2019 1820 Sherry Dr Jacksonville,FL 32207 19.0.04 RSU23882 Atlantic Beach,FL 32233 Phone:9042451818 2019.1uL11 17:16:56 www.avalonac.com ...\Duct Layouts\1820 Sherry BS.nip Level 2 All Upstairs Duds are Existing and Bedroom 1 Bath 2 Unchanged tM 97 cfm CE3 39 c Bedroom 2 CECI 193 cfm RS Office 22 cf- Up Bath CM,213otn CEO,213ckn ® 32cfm Playroom Bedroom 3 E]Ex.Storage Aro 780 ®238 ckn Job M Avalon Heating and Air Scale:1 :100 Performed for: Page 2 Course Contracting 3665 Spring Park Rd RghtSuite®Universal 2019 1820 Sherry Dr Jacksonville,FL 32207 19.0.04 RSU23882 Atlantic Beach,FL 32233 Phone:9042451818 2019;Jukll 17:16:56 www.avalonac.com ...Tuct Layouts\1820 Sherry BS.nip Duct System Summa ry Job: + Wrightsof Date: Jul 11,2019 Master Area Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone.9042451818 Web.w ..avaIon ac.com License:CIVIC 1249968 Project Information For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.32 in H2O 0.32 in H2O Available static pressure 0.28 in H2O 0.28 in H2O Supply/return available pressure 0.140/0.140 in H2O 0.140/0.140 in H2O Lowest fiction rate 0.230 in/100ft 0.230 in/100ft Actual airflow 780 cfm 780 cfm Total effective length(TEL) 122 ft Supply Branch Detail • - Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (dm) FR (in) (in) Mab Ln(ft) Ln(ft) Trunk closet h 3024 348 38 0.343 4.0 Ox 0 VIFx 11.7 70.0 closet c 606 0 32 0.384 4.0 Oxo VIFx 3.0 70.0 Dining c 303 0 16 0.230 4.0 Ox 0 RtFg 17.0 105.0 st3 Laundry-A c 658 0 35 0.235 4.0 Ox 0 RtFg 14.0 105.0 st3 Master c 5875 227 309 0.384 10.0 12x 8 RtFg 3.0 70.0 Master Bath c 6383 205 335 0.364 6.0 Oxo VIFx 7.0 70.0 Mud Room c 303 0 16 0.332 4.0 Ox 0 VIFx 14.2 70.0 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 PeakAVF 0 50 0.230 145 8.0 0 x 0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk rb1 Oxo 780 780 0 0 0 0 Ox 0 VIFx wrightsoft 2019-Jul-1117:16:12 Right-SuiteO Universal 201919.0.04 RSU23882 Pagel /:9l'.•.liiK ...rsWome\DropboxM)uctLayouts\1820 Sherry BS.rup Calc=MJ8 Front Door faces:E Duct System Summary Job: wrightsoft Date: Jul 11,2019 Upstairs Zone 1 By: Avalon Heating and Air 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:www.avalonac.com License:CMC1249968 Project Information For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.32 in H2O 0.32 in H2O Available static pressure 0.28 in H2O 0.28 in H2O Supply/return available pressure 0.215/0.065 in H2O 0.215/0.065 in H2O Lowest friction rate 0.129 in/100ft 0.129 in/100ft Actual airflow 1167 cfm 1167 cf n Total effective length(TEL) 217 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (dm) FR (in) (in) Mab Ln(ft) Ln(ft) Trunk Bath 2 h 541 39 27 0 0 Ox 0 VIFx 0 0 Bedroom 1 h 1957 97 96 0 0 Ox 0 VIFx 0 0 Entry/Stairs C 2996 140 148 0.180 6.0 Ox 0 VIFx 24.8 95.0 St2 Family Room h 1794 97 83 0.129 6.0 Ox 0 RtFg 26.9 140.0 st4 FamilyRoonrA h 1794 97 83 0.129 6.0 Oxo RtFg 26.9 140.0 st4 Family RoortrB h 1794 97 83 0.141 6.0 Ox 0 RtFg 22.9 130.0 st4 Guest Bath h 997 54 14 0.168 4.0 Oxo VIFx 32.9 95.0 st2 Kitchen h 2173 117 115 0.190 7.0 OX 0 VIFx 23.4 90.0 st2 Kitchen-A h 2173 117 115 0.200 7.0 Ox 0 VIFx 17.3 90.0 st2 Living c 2461 95 121 0.179 7.0 Ox 0 VIFx 30.0 90.0 st1 Living-A c 2461 95 121 0.178 7.0 Ox 0 VIFx 31.1 90.0 st1 Living-B C 2461 95 121 0.179 7.0 Ox 0 VIFx 30.0 90.0 SO Office c 523 6 26 0 0 Ox 0 VIFx 0 0 Rs h 285 22 14 0 0 Ox 0 VIFx 0 0 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st4 PeakAVF 290 249 0.129 532 10.0 0 x 0 VinlFlx st2 st2 PeakAVF 718 640 0.129 672 14.0 0 x 0 VinlFlx st1 PeakAVF 284 364 0.178 463 12.0 0 x 0 VinlFlx wrightsoft" 2019-Jul-1117:16:12 Right-SUlta®Universal 2019 19.0.04 RSU23882 Page 2 ACCK ...rsftme\Dropbox\Duct Layouts\1820 Sherry BS.rup Calc=MJ8 Front Door faces:E Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (Cfrr1) (tfrrl) (ft) FR (fpm) (in) (in) Opening(in) Mab Trunk rb2 Ox 0 1167 1167 50.4 0.129 1092 14.0 Ox 0 VIFx wrightsoft" 2019-Jul-11 17:16:12 ^'� ,�,.�•,...,.�,,.„.�.e_�.>_p,� Right-SuiUe®Universal 201919.0.04RSU23882 Page3 �C� ...rsWomelDropboxlDud Layouts\1820 Sherry 13S.rup Calc=W8 Front Door faces:E Duct System Summary Job: +}+ wrightsoft Date: Jul 11,2019 Upstairs Zone 3 By. Avalon Heating and Air 3665 Spring Park Rd,Jacksonville.FL 32207 Phone.9042451818 Web.w .avalona acorn License.CMC1249968 Project Information For: Course Contracting 1820 Sherry Dr,Atlantic Beach,FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.23 in H2O 0.23 in H2O Available static pressure 0.27 in H2O 0.27 in H2O Supply/return available pressure 0.135/0.135 in H2O 0.135/0.135 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual airflow 780 dm 780 cf n Total effective length(TEL) 0 ft SupplyDetail Table Design Htg Clg Design Diam H x W Dud Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mab Ln(ft) Ln(ft) Trunk Bedroom 2 h 2414 193 158 0 0 Ox 0 VI Fx 0 0 Bedroom h 2687 238 176 0 0 Oxo VIFx 0 0 Playroom c 3243 158 213 0 0 Ox 0 VIFx 0 0 Playroom-A c 3243 158 213 0 0 Oxo VIFx 0 0 Up Bath h 314 32 21 0 0 Ox 0 VI Fx 0 0 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Dud Name Size(in) (dm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mab Trunk rb3 Ox 0 780 780 0 0 0 0 Ox 0 VIFx wrightsoft', 2019-Jul-1117:16:12 Right-SuiteOUniversal 2019 19.0.04 RSU23882 Page 4 ACC*, ...rsV iome\Dropbox\Duct Layouts\1820 Sherry BS rup Calc=MJ8 Front Door faces:E = _jz NOTCHED BTM. Z r 2 FLANGE 1101ST C) S-4 LOCATIONS. m H REPAIR PERQ DETAIL (� Q V O (2)2.0E 1.75"x9.25"GP REMOVE EXIST. Q o 2:2 FLOOR JOIST Z X --- INSTALL NEW 14"TJI a Q a 360 I-JOISTS AT 24" "J LL. m O.C.FULL SPAN fn FILL IN FRAMING � � � PER TYP.WALL OQ — W SECTIONS LL LL ul "EXISTING 0 Q UJ W }: FLOOR JOIST W >' n' CC m DIRECTION W 0 Lu 0 Lu W V N Lu :�: W LLI 5; 2x8 (C w 22 PLACE 3-PLY CC STUD GROUP AT BEAM BEARING A y TJI FLOOR JOIST REPAIR PLAN 8d(.113'x2.5')NAILS AT 6"O.C. SCALE: 3/16" - ALONG TOP AND BTM. FLANGE,TYP. Zo 0 EXIST.14"TJ1360 FLOOR JOISTS U AT 24"O.C.,TYP. Q O (L a PLYWOOD SCAB REPAIR - NOTCH GLUED&NAILED TO TOP&BTM J mQ FLANGES,EACH SIDE Z_ U , O O O F j 8d(.113"x2.5")NAILS AT 6"O.C. a o ALONG TOP AND BTM. FLANGE,TYP. C.E FV ♦ � •......• R /pit NOTCH LOCATION ALONGifM. PLAN VIEW 17 FLANGE,TYP. : 803,5' � * • �� SECTION VIEW ✓� TJI REPAIR DETAIL,TYP. �� . 9 :� � , : '. STATE TE O OF 1 .o . % Ali. v��la'V+iTr�o' NOTCHED TJI REPAIR PROJECT#: 1811111% DETAIL ■■ MARTIN ENGINEERING, LLC. DATE: 7/17119 ■■ 450 STATE ROAD 13 N.#106-387 YOUNG RESIDENCE ■■■ JACKSONVILLE,FL 32259 DRAWN: KCM ■■■ 904-472-1459 1820 SHERRY DRIVE N. S-1 .3 ATLANTIC BEACH, FL DESIGNED: KCM FL C.A#3202 SCALE: AS NOTED