1612 Atlantic Beach Dr RES18-0264 Env. Leakage Test - - -. ----tom - - -� .; � - ' 1 FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION JOB COPY Envelope Leakage Test Report Performance.Method Project Name: The Anna Maria 3344 Right E Builder Name: Toll Brothers,Inc. Street: Lot 158 Atlantic Beach CC— (D I'Z 1-fi j a n tl(Permit Office: Duval City,State,Zip: Atlantic Beach, FL, beach .pri vl� Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 3344 sq.ft. Cond.Volume: 32102 cu ft. Envelope Leakage Test Results , Leakage Characteristics Regression Data: C; n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 : �— 7 1 Pa —I cfm 2 Pa cfm Tested ACH(50) P 3 Pa cfm *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553,993(5)or(7),Florida Statutes or individuals licensed as set forth In Section 489.105(3)(f), (g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: _ . .. . 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either VIAE SN performance results demonstrate compliance individuals as defined in Section with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes ori,,,f c individuals licensed as set forth in +++r++ = accordance with Section R402.4.1.2. ^rim Section 489.105(3)(f), (g),or(i)or an approved third party.A written report of 0 I1!�l i . the results of the test shall be signed SIGNATURE: by the third party conducting the test -41 and provided to the code official. COD WE PRINTED NAME: BUILDING OFFICIAL: �/r1 DATE: 7h J I )9 DATE: 0 6/25/2018 5:14 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1