Loading...
380 12th St RES19-0045 Rev OFFICE Mr-1 "ALL INFORMATION Revision Request/Correction to Comments HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Build ing-Dept@coa b.us PERMIT#: W(Revision to Issued Permit OR Corrections to Comments Date: IV Project Address: 350 1 — Contractor/Contact Name: TA Lvo,9 C'0 M Contact Phone: Email: Description of Proposed Revision Corrections: A)ttJ tvkowJ lor P,4z V R. CEIVED affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) JUL 15 2019 • Wffl proposed revision/corrections add additional square footage to original submittal? r�No El Yes (additional s.f.to be added: Building Department CitY of Atlantic Beach, FL • WijWroposed revision/corrections add additional increase in building value to original submittal? KN o []*Yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/A encL-L��- (Office Use Only) [OrApproved Denied Not Applicable to Department Permit Fee Du4-�O_- Revision/Plan Review Comments 41-'On Lf PIT�- 75-0 12,q;e Department Review Required: B uii I I�in g Z( Zoning 0 Reviewed By Tree Administrator Public Works Public Utilities 7'/ k Public Safety Date Fire Services Updated 10/17118 Manual S Compliance Repo ob: 4649 Pollak Res 380 12th... Date: 1/10/19 wrightsoft "REVISION ' (Unconditioned) E3P# /26>S -004IS-ey: RH Air Flow Designs, Inc DATE—-7 - OFFICE COPY 250 Jasmine Rd.Casselberry.FL 32718 Phone (407)831-3600 Web:http:/,VNmaidovAesigns.corTv SIGNED— Ar Project Information For: J A Long Cooling Equipment Design Conditions Outdoor design DB: 95.7'F Sensible gain: 0 Btuh Entering coil DB: O'F Outdoor design WB: 77.1'F Latent gain: 0 Btuh EnteringcoilWB: -3.17 Indoor design DB: 75.0'F Total gain: 0 Btuh Indoor R H-. 50% Estimated airflow. 0 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: Split AC Manufacturer Model: Actual airflow: 0 cfm Sensible capacity: 0 Stuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB.- 36.8'F Heat loss: 0 Btuh Entering coil DB: O'F Indoor design D B: 70.O'F Manufacturer's Performance Data atActual Design Conditions Equipment type: Gas furnace Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 0 Btuh 0% of load Temp. rise: 0 *F Meets all requirements of ACCA Manual S. At;. Ad- wrightsoft, 2010-Jukll 15:01:18 —1--1-11-1.11-11--11 Right-Suite&universal 2019 19.0.08 RSU20502 Page 1 j9M y%Esbmabng�AFD-Centra1\JA1_4649 POLLAK RES.rup Calc=MJ8 House faoes NW wrightsoft, Manual S Compliance Report Job: 4649 Pollak Res 380 12th Date: 1/10/19 By: RH 'Airfl�woesk,gnt-, Inc 250 Jasmine Rd,Casselberry.FL 32718.2boLie:1407=1,3WO—Web�hap:k�airnovmesigns.conv Project Information For: J A Long Cooling Equipment Design Conditions Outdoor design DB: 95.7*F Sensible gain: 20135 Btuh Entering coil DB: 77.0'F Outdoor design WB: 77.1'F Latent gain: 6034 Btuh Entering coil WB: 64.2*F Indoor design DB: 75.OoF Total gain: 26169 Btuh Indoor R H: 50% Estimated airflow: 875 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: SplitASHP Manufacturer Carrier Model: 25HCE4300003+FB4CNP030L Actual airflow: 875 cfm Sensible capacity: 20071 Btuh 100% of load Latent capacity: 4857 Btuh 80% of load Total capacity: 24928 Btuh 95% of load SHR: 81% Heating Equipment Design Conditions Outdoor design DB: 36.8'F Heat loss: 31080 Btuh Entering coil DB: 70.0'F Indoor design DB: 70.O'F Manufacturer's Performance Data atActual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HCE4300003+FB4CNP030L Actual airflow. 0 cfm Output capacity'. 22386 Btuh 72% of load Capacity balance: 38 'F Supplemental heat required: 8694 Btuh Economic balance: -99 oF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity'. 8.0 kW 88% of load Temp. rise: 50 'F Meets all requirements ofACCA Manual S. A� * wrightsoft- Right-Suite&Universal 2019 19.0.08 RSU20502 2019-Jul-11 15:01:18 I- .­­­­­ Page 2 ACCK )�Estimabng%AFD-CenbaPJAL4&49 POLLAK RESrup Calc=MJ8 Housefaces:NVV wrightsoft, Manual S Compliance Report Job: 4649 Pollak Re.380 12th... Date: 1/10/19 2F By: RH Air Flow Designs, Inc OFFICE COPY 250 Jasmine Rd,Casselberry,FL 32718 Phone:(407)831-3600 Web:hftP:/M%W8irflowdesigns.Co" —Project Information For J A Long Cooling Equipment Design Conditions Outdoor design DB: 95.7'F Sensible gain: 23182 Btuh Entering coil DB: 75.VF Outdoor design WB: 77.1'F Latent gain: 6952 Btuh Entering coil WB.- 62.6'F Indoor design DB: 75.O'F Total gain: 30135 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HCE442CO0300+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 28523 Btuh 123% of load Latent capacity: 10156 Btuh 146% of load Total capacity: 38679 Btuh 128% of load SHR: 74% Heating Equipment Design Conditions Outdoor design DB: 36.8*F Heat loss: 22259 Btuh Entering coil DB: 70.0'F Indoor design DB: 70.O'F Manufacturer's Performance Data atActual Design Conditions Equipment type: SplitASHP Manufacturer Carrier Model: 25HCE442CO0300+FB4CNP042L Actual airflow: 0 cfm Output capacity: 33558 Btuh 151% of load Capacity balance: 20 *F Supplemental heat required: 0 Btuh Economic balance: -99 *F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 5.0 kW 77% of load Temp. rise-. 13 'F Meets all requirements of ACCA Manual S. wrightsoft- 2019-Jul-11 15:01 18 Righl-SuiteO Universal 2019 19.0.08 RSU20502 Page 3 XsbrnatwAFD-Cen1ral\jAL4649 POLLAK RESrup Calc=MJ8 House faoes NW