30 N Saratoga Cir ACC19-0066 ShedNOTES: THESE DRAWINGS AND THE 1. BUILDING CODE: FLORIDA BUILDING CODE, 6th EDITION (2010 BUILDINGS ARE NOT FOR HIGH -VELOCITY HURRICANE ZONE OF TUFF SHED, INC. THESE (HVHZ) DRAWINGS ARE FOR A 2. DESIGN LOADING: BUILDING TO BE SUPPLIED WIND SPEED: V'it = 155 Checked By: Vasd = 120 Date: Scale: N.T.S. EXPOSURE: C ROOF LIVE LOAD: 20 PSF ROOF DEAD LOAD: 10 PSF FLOOR LIVE LOAD: MIN. 50 PSF (SEE NOTE 5, DETAIL 1, SHEET 3) RISK CATEGORY: I COMPONENT AND CLADDING: ROOF: 29 PSF (ZONED WIND PRESSURE (psf (ASD VALUES) 50 PSF (ZON :� (BASED ON 10 SQ FT) 74 PSF (ZONE: WALL: 34 PSF (ZONE: 42 PSF (ZONE :51 FLORIDA BUILDING APPROVAL NUMBERS -- 1. WINDOWS BY TAFCO CORP - FLORIDA BUILDING APPROVAL #FL20743.1. 2. WINDOWS BY SILVER LINE BUILDING PRODUCTS CORP - FLORIDA BUILDING APPROVAL FL14911.5. 3. LP SMARTSIDE SIDING - FLORIDA BUILDING APPROVAL #FL919D.6. 4. ROOF UNDERLAYMENT BY WOODLAND INDUSTRIES INC. - FLORIDA BUILDING APPROVAL #FL17206.1. 5. ROOF UNDERLAYMENT BY GAF - FLORIDA PRODUCT APPROVAL #FL18686.1 6. SHINGLES BY OWENS CORNING - FLORIDA BUILDING APPROVAL #FL10674.1. 7. SHINGLES BY GAF - FLORIDA PRODUCT APPROVAL #FL10124.1 8. INNOVATIONS MANUFACTURING, INC. TRANSOM WINDOWS - FLORIDA BUILDING APPROVAL #FL17667.1. 9. FLOOD SOLUTIONS, LLC FLOOD VENTS (IF REQ'D)- FLORIDA BUILDING APPROVAL #FL17588.1. 10. OX PAPERBOARD MICHIGAN, LLC THERMO-PLY SHEATHING - FLORIDA BUILDING APPROVAL #FL16391.1. 11. TUFF SHED, INC DOORS - FLORIDA BUILDING APPROVAL #FL22202.1, #FL22202.2, #FL22202.3, #FL22202.4 HEADER NAILING: HEADER TO STUD - 4-16d END NAIL DOUBLED HEADER - 16d @ 16" STAGGERED FACE NAIL NAILING: REFER TO SHEET 2 FOR WALL AND ROOF SHEATHING NAILING. MAX WALL HEIGHT FOR EACH SHED: SR600 - 5-8 1/4" (68 1/4") TR700 - 6'-8 1/4" (80 1/4") PR - 6-8 1/4" (80 1/4") TUFF SHED Storage Buildings & Garages TUFF SHED, MFG. FACILITIES Order #. Customer: Site Address: Building SIZe.WIDTH-LENGTH -HEIGHT -3Q.FT AREA UNINHABITED UTILITY SHED UP TO 12' WIDE x UP TO 24' LONG SR6001 TR700, PR OVERHANG OPTIONS T REFER TO THE TRUSS DESIGN FOR LUM/ .d� AND BPLATE SIZE ER SIZE, USS SPACING r COLLAR TIE REQUIRED ONLY AT 12' WIDE SHEDS, SEE TRUSS CALCULATIONS 12 4 SEE SHEET 3 FOR STEEL FLOOR WITH ANCHOR DETAIL OR FOUNDATION DETAIL UP TO 12' WIDE OBUILDING SECTION SCALE: N.T.S. DOUBLE TOP PLATE CRIPPLES (IF REQ.) HEADERS FOR OPENINGS UP TO 4'-0" USE (2) 2x4 SPF #2 2x4 WINDOWSILL FLOOR DECKING BASE PLATE I-- � r —J FOR WINDOW OPENINGS UP TO 4'-0" WINDOW HEADER DETAIL FOR SIDE WALLS SCALE: N.T.S. P.O. # THESE DRAWINGS AND THE DESIGN ARE THE PROPERTY Drawn By: PK OF TUFF SHED, INC. THESE DRAWINGS ARE FOR A Date: 3/12/19 BUILDING TO BE SUPPLIED AND BUILT BY TUFF SHED. Checked By: ANY OTHER USE IS FORBIDDEN BY BOTH TUFF SHE AND THE ENGINEER OF RECORD Date: Scale: N.T.S. RAFTER FLORIDA APPROVED OWENS CORNING OAKRIDGE 30 YEAR SHINGLES - FL10674-R10 SEE THE TRUSS SIMPSON H2.5A PL INSIDE AT EACH I CONNECTION DETAIL - DETAIL 2 WALL TOP WALL FRAMING TO BE 2x4 SPF #2 OR BETTER @ 16" O.C. IF BUILDING IS LOCATED IN A FLOOD ZONE THEN FLOOD VENTS AND PRESSURE TREATED STUDS ARE REQUIRED - ONE SQ INCH VENT FOR EVERY ONE SQ FT OF BUILDING ^7UBLE TOP PLATE RIPPLES (IF REQ.) TOE NAIL WITH (3) 60 NAILS, (2) ONE IDE, (1) OTHER IDE OTRUSS TO WALL CONNECTION DETAIL SCALE: N.T.S. FADERS FOR I JPENINGS UP O 4'-0" USE (2) 2x4 SPF #2 JPENINGS 4'-1 ' TO 6-0" USE (2) 2x6 S+ #2 JPENINGS 6'-'J" TO 8'-0" USE (2) 2x8 SPF #2 NG STUD RIMMER OORr FOR OPENINGS U� TO 8' DOOR H 36 FOR SIC SCALE. N.T.S. TUFF SHED, INC. ENGINEERING DEPARTMENT RICHARD J. WILLS, P.E. 1777 S. HARRISON STREET DENVER, COLORADO 80210 (303) 753-8833 EXT. 96315 TE =CKI IL 6)ft 'rL f�f�i 7835 i ��^' TAT OF f}}` I-- — — CRIPPLE STUD HEADERS FOR: OPENINGS UP TO 6-0" USE (2) 2x4 SPF #2 OPENINGS 6-1" TO 8'-0" USE (2) 2X6 SPF #2 REFER TO THE DOOR DETAIL (SHEET 2) FOR THE DOOR DESIGN 4 HEADER DETAIL FOR END WALLS SCALE. N.T.S. TITLE I DRAWING NO. FL -PR -SR -TR -01 BUILDING SECTIONS HEADER FRAMING DETAILS I REV. LEVEL 01 FBC, 6th EDITION (2017) I SHEET 1 155C PAGE 1 OF 4 #12-14 X 3" HEX HEAD— SELF-DRILLING SCREWS 3/4" APA OR TECO RATED T&G FLOOR DECKING. 2X6 STEEL JOISTS - @ 24" OC #10 X 3/4" PAN HEAD SELF -DRILLING SCREWS (2 PER TAB) VENT HOLES @ 24" OC. ---- OPTIONAL LEVELING BLOCKS 2X6 STEEL TRACK EACH END BASE PLATE SCREW SPACING WIDTH SPACING 6'-12' 8" O.C. OSTEEL SHED BASE DETAIL SCALE: N.T.S. SIDING TRIM 3/8" CARRIAGE BOLT (GRADE 2) OT17SWB -OR- OT24SWB 1. STEEL SHED FOUNDATION: 600T125-054 - 16 GAUGE STEEL TRACKS G140 ZINC COATED 600S137-054 - 16 GAUGE STEEL JOISTS G140 ZINC COATED @ 24" O.C. (SUPPLIER: ALLIED STUDCO (JOIST: 600S137-054 / TRACK. - 600T125 -054) ICC ER -4943P. 1 2. 3/4" APA OR TECO RATED TONGUE AND GROOVE FLOOR DECKING. 24" MAX PANEL SPAN. STAGGER PANEL LAYOUT. 3. FASTEN FLOOR DECKING TO JOIST & TRACKS USING #8 x 1-5/8" ZINC PLATED SCREWS @ 12" O.C. NO BLOCKING REQUIRED. ALL EDGES SHALL LIE ON FLOOR JOISTS. STAGGER PANEL LAYOUT PER APA CONDITION 1. 4. FASTEN SOLE PLATE THROUGH FLOOR DECKING INTO JOISTS OR TRACKS WITH #12-14 X 3" GALVANIZED SELF -DRILLING i I'I SCREWS. REFERENCE SPACING CHART. i 5. ALLOWABLE FLOOR LIVE LOAD: 75 PSF FOR STEEL JOISTS CONTINUOUSLY SUPPORTED. 50 PSF FOR JOISTS ON BLOCKS AS SHOWN. 6. USE OPTIONAL CONCRETE BLOCKS AS REQUIRED TO LEVEL BUILDING: SUGGESTED SIZES: 2" x 8" x 16", 4" x 8" x 16", OR 8" x 8" x 16". BLOCKS UNDER JOISTS SPACED @ 8'-0" O.C. MAXIMUM. BLOCKS UNDER TRACK SPACED @ 4'-0" O.C. MAXIMUM. a Sl"UD 3/8" NYLON LOCK NUT z r BASEPLATE FLOOR PLY v / /_ - 1/2" HILTI KWIK BOLT TZ STAINLESS STEEL 304 EMBEDMENT DEPTH = 2 1/4" STEEL SHED MIN. EDGE DISTANCE = 6" BASE ANCHOR SPACING: RE: KWIK 4" CONCRETE BOLT ANCHORS TABLE, SHEET 3 PFFD (MIN) OSIDEWALL BRACKET DETAIL SCALE: N.T.S. Order #. TUFF SHED Customer: Storage Buildings & Garages Site Address: TUFF SHED, MFG. FACILITIES Checked By: �+ [Da Building SIZe:WIDTH-LENGTH - HEI GHT-SQ.FT.AREA Scale: N.T.S. KWIK BOLT ANCHORS (INTO CONCRETE E: DETAIL 3 SHEET 3 WIDTH LENGTH QTY 6' 6'-10' 6 6' 12'-18' 8 8' 8'-14' 6 8' 16'-20' 8 8' 22'-24' 10 10' 10'-16' 6 10' 18'-24' 8 12' 12'-18' 6 12' 20'-24' 8 NOTES: 00 12� 1. ANCHORS TO BE KWIK BOLT TZ, 304 SS 2 2. PROVIDE (1) ANCHOR AT EA. CORNER OF THE BUILDING. THE REMAINING ANCHORS EQUALLY SPACED ALONG THE LENGTH OF THE BUILDING. (1/2 THE REMAINING ANCHORS ON EA. LENGTH SIDE EQUALLY SPACED). P.O. # Drawn By: PK Date: 3/12/19 THESE DRAWINGS AND THE DESIGN ARE THE PROPERTY OF TUFF SHED, INC. THESE DRAWINGS ARE FOR A BUILDING TO BE SUPPLIED AND BUILT BY TUFF SHED, ANY OTHER USE IS FORBIDDEN BY BOTH TUFF SHED AND THE ENGINEER OF RECORD y TRIM SIDING AUGER ANCHOR COMPONENTS BY OLIVER TECHNOLOGIES 2X4X2' • PART NUMBERS: BLOCK OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER ATTACH BRACKET TO OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS STUD THRU HOLE IN REPORT NO. LO-FJ90129-A ANCHOR PLATE WITH -OR- 3/8"0 x 4" CARRIAGE OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS BOLT AND LOCKNUT REPORT NO. LO-FJ90129-B `r CORNER STUD • WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS WITH THE MAXIMUM LOAD OF 5,080 LBS U >- FINISH cel ~ GRADE ANCHOR BRACKET TO BE FLUSH WITH OAUGER ANCHOR DETAIL EDGE OF TRIM SCALE: N.T.S. 'y UNHEATED SPACE �Ia 3" CLR. U TYP. Cl) 8" MIN. 0 CONCRETE FOUNDATION SCALE: N.T.S. TUFF SHED, INC. ENGINEERING DEPARTMENT RICHARD J. WILLS, P.E. 1777 S. HARRISON STREET DENVER, COLORADO 80210 (303) 753-8833 EXT. 96315 ANCHOR BOLT & P.T. SILL PLATE PER NOTES BELOW #4 CONTINUOUS TOP & BOTTOM CONCRETE FLOOR SLAB REINFOCEMENT PE$\NO ES BELOW SLAB CONTINUOUS FOOTING NOTES 1. TOP OF SLAB TO BE 6" MIN. ABOVE GRADE. SLAB REINFORCEMENT SHALL BE WWF 6X6 W1.4xW1.4 . LOCATE AT MID -DEPTH OF SLAB. -OR- SLAB REINFORCEMENT SHALL BE FIBERMESH 150 OR BLENDED FIBERMESH150. FIBERMESH SHOULD BE DISPERSED UNIFORMLY THROUGH CONCRETE W/ MIN. 1 POUND PER CUBIC YARD OF CONCRETE. 2. ALL FOOTING FORMS SHALL BE INSPECTED FOR SIZE AND REINFORCING BEFORE POURING CONCRETE. 3. FOOTINGS SHALL BEAR ON UNDISTURBED NATURAL, COMPETENT SOIL, OR PROPERLY COMPACTED STRUCTURAL FILL. ALLOWABLE SOIL BEARING PRESSURE IS 1000 PSF AT 12" BELOW GRADE. 4. CONCRETE: MINIMUM 28 DAY COMPRESSIVE STRENGTH, Pc = 2500 PSI. 5. REINFORCING STEEL: A615, GRADE 40 OR GRADE 60. ALL REINFORCING STEEL SHOWN TO BE CONTINUOUS MAY BE LAPPED A MINIMUM OF 38 BAR DIAMETERS OR 24" MINIMUM, WHICHEVER IS LARGER. 6. SEISMIC DESIGN CATEGORY: A A. ATTACH PRESSURE TREATED SOLE PLATE TO THE FOOTING USING 1/2" DIA X 8" LONG SIMPSON TITEN HD ANCHOR WITH WASHERS. B. EXPANSION BOLTS SHALL BE EMBEDDED AT LEAST 5" INTO THE CONCRETE AND SHALL BE SPACED NOT MORE THAN 6' OC. C. THERE SHALL BE A MINIMUM OF 2 BOLTS PER SOLE PLATE PIECE WITH 1 BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 7 BOLT DIAMETERS FROM EACH END OF EACH PIECE. e- �� \\ �t1�Iillri�/�_ G NQS R *61 No 7835 TAT OF �eQ •' 1/1111111111\\\ TITLE DETAILS FBC, 6th EDITION (2017) 155C DRAWING NO. FL -PR -SR -TR -01 REV. LEVEL 01 SHEET 3 PAGE 3 OF 4 AUGER ANCHORS STUD -,,WIDTH LENGTH # OF ANCHORS 2K W 6' 6'-18' 4 ANCHORS 8' 8'-24' 4 ANCHORS 10' 10'-24' 6 ANCHORS q STUD 12' 12'-24' 6 ANCHORS M SIDING 4 -ANCHORS PROVIDE (1) AT EA. CORNER OF THE BUILDING. 6 -ANCHORS PROVIDE (1) AT EA. TRIM CORNERS OF THE BUILDING AND (1) AT T_ END WALL THE CENTER OF EA. SIDE WALL. ANCHOR BRACKET TO BE FLUSH WITH OAUGER ANCHOR DETAIL EDGE OF TRIM SCALE: N.T.S. 'y UNHEATED SPACE �Ia 3" CLR. U TYP. Cl) 8" MIN. 0 CONCRETE FOUNDATION SCALE: N.T.S. TUFF SHED, INC. ENGINEERING DEPARTMENT RICHARD J. WILLS, P.E. 1777 S. HARRISON STREET DENVER, COLORADO 80210 (303) 753-8833 EXT. 96315 ANCHOR BOLT & P.T. SILL PLATE PER NOTES BELOW #4 CONTINUOUS TOP & BOTTOM CONCRETE FLOOR SLAB REINFOCEMENT PE$\NO ES BELOW SLAB CONTINUOUS FOOTING NOTES 1. TOP OF SLAB TO BE 6" MIN. ABOVE GRADE. SLAB REINFORCEMENT SHALL BE WWF 6X6 W1.4xW1.4 . LOCATE AT MID -DEPTH OF SLAB. -OR- SLAB REINFORCEMENT SHALL BE FIBERMESH 150 OR BLENDED FIBERMESH150. FIBERMESH SHOULD BE DISPERSED UNIFORMLY THROUGH CONCRETE W/ MIN. 1 POUND PER CUBIC YARD OF CONCRETE. 2. ALL FOOTING FORMS SHALL BE INSPECTED FOR SIZE AND REINFORCING BEFORE POURING CONCRETE. 3. FOOTINGS SHALL BEAR ON UNDISTURBED NATURAL, COMPETENT SOIL, OR PROPERLY COMPACTED STRUCTURAL FILL. ALLOWABLE SOIL BEARING PRESSURE IS 1000 PSF AT 12" BELOW GRADE. 4. CONCRETE: MINIMUM 28 DAY COMPRESSIVE STRENGTH, Pc = 2500 PSI. 5. REINFORCING STEEL: A615, GRADE 40 OR GRADE 60. ALL REINFORCING STEEL SHOWN TO BE CONTINUOUS MAY BE LAPPED A MINIMUM OF 38 BAR DIAMETERS OR 24" MINIMUM, WHICHEVER IS LARGER. 6. SEISMIC DESIGN CATEGORY: A A. ATTACH PRESSURE TREATED SOLE PLATE TO THE FOOTING USING 1/2" DIA X 8" LONG SIMPSON TITEN HD ANCHOR WITH WASHERS. B. EXPANSION BOLTS SHALL BE EMBEDDED AT LEAST 5" INTO THE CONCRETE AND SHALL BE SPACED NOT MORE THAN 6' OC. C. THERE SHALL BE A MINIMUM OF 2 BOLTS PER SOLE PLATE PIECE WITH 1 BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 7 BOLT DIAMETERS FROM EACH END OF EACH PIECE. e- �� \\ �t1�Iillri�/�_ G NQS R *61 No 7835 TAT OF �eQ •' 1/1111111111\\\ TITLE DETAILS FBC, 6th EDITION (2017) 155C DRAWING NO. FL -PR -SR -TR -01 REV. LEVEL 01 SHEET 3 PAGE 3 OF 4 3X4 20 PLATES T-0" 1 EACH SIDE r 3; 12 Q 4 0 0 00 6'-0" LID N 3X4 20 PLATES r0000 �i LO 1 EACH SIDE Ch 4'-0" 4',2 1/2n 12 Q 4 00 o 00 8'-0" LO CV DESIGN LOADS: TOP CHORD LIVE LOAD = 20 PSF TOP CHORD DEAD LOAD = 10 PSF COLLAR TIE DEAD LOAD = 5 PSF NOTES: FBC, 6th EDITION (2017) ANSI/TPI 1-2007 TRUSSES TO BE SPACED @ 24" OC MATERIAL TO BE 2X4 SPRUCE PINE FIR GRADE #2 OR BE17ER PLATES ARE TO BE PRESSED IN THE WOOD PER TPI. REP MEMBER INCREASE: YES LUMBER D.O.L.: 1.25 00 tV CV r 5'-0" 18.0° 00 10'-0" fV 6'-0" 9' I — 3X4 20 GA PLATE 1 EACH SIDE 6' SPAN REACTIONS: Q1z MAX. VERTICAL: 180 LBS. 4 MAX. UPLIFT: -160 LBS. 3X4 20 GA PLATES 1 EACH SIDE 3X6 20 GA — PLATES 1 EACH SIDE 6'-0" 12'-0" NOTE: TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 12FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. 10'SPAN REACTIONS: MAX. VERTICAL: 300 LBS. MAX. UPLIFT: -250 LBS. NOTE: TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 20FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. MAXIMUM DEFLECTION (12 FT. SPAN) VERT LL: 0.06 in. VERT TL: 0.08 in. 8' SPAN REACTIONS: MAX. VERTICAL: 240 LBS. MAX. UPLIFT: -195 LBS. NOTE: TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 14FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. 12' SPAN REACTIONS: MAX. VERTICAL: 390 LBS. MAX. UPLIFT: -285 LBS. NOTE: TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 24FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. WIND: ASCE 7-10,155 mph, Exposure C, D.O.L.=1.60 PLATES ARE MANUFACTURED BY EAGLE METAL PRODUCTS, ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING THIS TRUSS ARE TO DO SO IN ICC -ES #ESR -1082. ACCORDANCE TO THE RECOMMENDATIONS OF THE LATEST VERSION OF THE BCSI. Order #. P.O. # THESE DRAWINGS AND THE fj TUFF SHED INC. ��� s'=<<� pis TITLE DRAWING NO. DESIGN ARE THE PROPERTY ` C Customer: Drawn B : PK OF TUFF SHED INC. THE ENGINEERING DEPARTMENT o ,- TUFF S y SE FL -PR -SR -TR -01 DRAWINGS ARE FOR A N f335 TRUSS DETAILS Storage Buildings & Gara eS Date: 3/12/19 BUILDING TO BE SUPPLIED g g g Site Address: AND BUILT BY TUFF SHED. RICHARD J. WILLS, P.E. ®• .; __ REV. LEVEL 01 TUFF SHED, MFG. FACILITIES Checked By: ANY OTHER USE IS 8524 EAST COLONIAL DRIVE FORBIDDEN BY BOTH TUFF 1777 S. HARRISON STREET •;� FBC, 6th EDITION (2017) SHEET ORLANDO, FL 32817 Date: SHED AND THE ENGINEER OF DENVER COLORADO 80210 ••• s ATE O F (888)788 -TUFF Building Size:WIDTH-LENGTH-HEIGHT-SQ. Ff. AREA ,, STORE 520 Scale: N.T.S. RECORD (303) 753-8833 EXT. 96315 ���f!/'�S, ,aaLa �� 155C PAGE 4 OF 4 IBII►illi�