89 West 2nd Street ROW19-0025 50' Pole RIGHT OF WAY PERMIT PERMIT NUMBER
ROW19-0025
CITY OF ATLANTIC BEACH ISSUED: 8/12/2019
800 SEMINOLE ROAD
ATLANTIC BEACH. FL 32233 EXPIRES: 11/10/2019
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL • 'K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' + BUILDING
CODE, ' AND OF ATLANTIC +CH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts,state agencies, or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
89 W 2ND ST RIGHT OF WAY SINGLE OR TWO 50' POLE $0.00
FAMILY RIGHT OF WAY
TYPE OF
ZONING: :D •
• • •
170836 0000 ATLANTIC BEACH SEC H
COMPANY: ADDRESS:
• ADDRESS:
BCEL 8 LLC 7563 PHILIPS HWY 4109 JACKSONVILLE FL 32256
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
P -
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells, Inc.,Republic Services,Donovan Dumpsters,
Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way.
Issued Date: 8/12/2019 1 of 2
RIGHT OF WAY PERMIT PERMIT NUMBER
s, CITY OF ATLANTIC BEACH
ROW19-0025
800 SEMINOLE ROAD ISSUED: 8/12/2019
ATLANTIC BEACH. FL 32233
EXPIRES: 11/10/2019
3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration,including sod,is required.
4 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
5 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
6 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL
Notes:
See attached Utility Map.
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
Issued Date:8/12/2019 2 of 2
riyLy;y�, City of Atlantic Beach �V APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
800 Seminole Road AUG 01 2 I
Atlantic Beach, Florida 32233-5445 9 0
Phone(904)247-5826 - Fax(904)2 45
^�� 9 E-mail: building-dept@coab.us 6 Date routed:
City web-site: http://vmw.coab.us
APPLICATION REVIEW AND TRACKING FORM
<�f> 9 Z
Property Address: C Department review required Yes No
Building
Applicant: -Franning &Zoning
ree minis ra o
LG
Public
v0or s
Project: PQ
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. []Denied. []Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING /, •.�
Reviewed b Date: i
TREE ADMIN. Second Review: A roved as revised.
❑ pp ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
rig:Lyr City of Atlantic Beach APPLICATION NUMBER
�s Building Department (To be assigned by the Building Department.)
800 Seminole Road I / 0 _t
j Atlantic Beach, Florida 32233-5445 l l- !�
Phone(904)247-5826 • Fax(904)247-5845 l
E-mail: building-dept@coab.us Date routed:
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
G� C, z i\.6 C
Property Address: CID Department review required Yes No
Building
Applicant: fanning &Zoning
reeminis ra o
Project: C RD,L& Public ors - y
Public Utilities >
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receiptof Permit Verified By
Date
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. ❑Denied. of applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: 4. e= zo?'P _ Date: ^�lei
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. []Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
rS!rLYr�� City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
r v 800 Seminole Road I
Atlantic Beach, Florida 32233-54459 w ��
v Phone(904)247-5826 • Fax(904)247-5845
E-mail: building-dept@coab.us L Date routed:
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: C:D V� Department review required Yes No
Building
Applicant: anning &Zoning
reeminis rrator--
Project: c Pc�)LC, Public Wor s
Public Utilities �;`
Public Safety
Fire Services
Review fee $ - Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept.of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLIC N STATUS
Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING
Reviewed by: a e. — T{
TREE ADMIN. Second Review: ❑Approved as revised. []Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/1912017
PUBLIC UTILITIES PLAN REVIEW COMMENTS
Date: Application#:
Project Address:
Check Box Check
APPLICATION TRACKING COMMENTS to Add Box to
Comment Print j
Underground Avoid damage to underground water and sewer utilities. Verify vertical and
Water Sewer horizontal location of utilities. Hand dig if necessary. if field coordination Is D d
Utilities needed, call 247-5878.
Meter Boxes Ensure all meter boxes,sewer cleanouts and valve covers are set to grade
Sewer Cleanout and visible. ❑ ❑
A sewer cleanout must be installed at the property fine. Cleanout must be
RT1 Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade ❑ ❑
Cleanout and visible.
A reduced pressure zone backflow preventer must be installed if irrigation will
RPZ be provided or if there is a private well on the property. Backflow preventer ❑ ❑
Backflow must be tested by a certified tester and a copy of the results sent to Public
Utilities.
Plans note the building will be unsprinkled. if plans change,any fire line
Sensus installed must be metered with a Sensus touch-read meter in a properly sized
Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer ❑ ❑
Meter must be tested by a certified tester and a copy of the results sent to Public
Utilities.
Fire Sprinkler if fire sprinkler system is provided,call 247-5878 for backflow requirements.
Backflow At a minimum,will require a double check backflow preventer. ❑ ❑
Requirement
Fire Line Fire lines must be metered with a Sensus touch-read meter. Meters larger ❑ 0
Meter than 2" must be installed in a vault as noted in JEA specifications.
Utility Map See attached Utility Map.
Disconnect
&Cap Disconnect and cap water and sewer lines. ❑ ❑
inspection Must call the inspection Line at 247-5814 to request an inspection of the
Prior disconnected and capped water and sewer lines prior to demolition. ❑ [3
❑ ❑
❑ ❑
❑ ❑
0 13
f
r Irk '..AP
fw
k, #
PVC WATER MAIN
!r-
fAl
�t.
t
,r
a ) t.
� sus-�„ RIGHT—OF-WAY/EASEMENT PERMIT APPLICATION "ALL INFORMATION
City of Atlantic Beach HIGHLIGHTED IN GRAY IS
800 Seminole Road,Atlantic Beach, FL 32233 REQUIRED.
fun 9"
PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES
RCD W 1-`�1 �
Job Address U W. Permit Number n
Contractor Information
Company �CrJ L f, Qualifying Agent
Address 7ij �es1 �U✓r/� S(/ City )�X State__Zip ��i7id7i
Phone Email
State Certification/Registration#
Architect Phone Email
Engineer I'V" yt Phone 66S-77 3 Email
Workers Compensation Insured I OR ExemptElExpiration Date
• Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial
and underground and the accurate locations are shown on the sketches.
• Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation,alteration or
relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles,
wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said
street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the
Permittee unless reimbursement is authorized.
• All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the
supervision of (Project Superintendent)
with(Company Name) Phone &6r- g 3
• All materials and equipment shall be subject to inspection by the Public Works Director.
• All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the
manner satisfactory to the City.
• A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit.
Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with
this application.
• The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60
days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no
changes have occurred in the area that would affect the permitted construction.
• It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,
title and interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of
and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of
expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges.
• Th I or �o�shall tified 24 hours prior to starting work and again immediately
pupon completion,
Date
Permittee(signed in presence of otary Public)
STATE OF FLORIDA,COUNTY OF DUVAL
The foregoing instrument was acknowledged this day of 20
by who personally appeared before me and
(printed name of Permittee)
acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it.
[ ]Personally Known
Signature of Notary Public,State of Florida [ ]Produced Identification(Type)
H:\Applications&Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date:10/1/18
ENGINEERING DESIGN
ORACLE PERMIT MAXIMO DATE REL
PROJECT#: 39549 N.O.; 8005212 WO#: 30462651 CONST: 08101/19
CIR. TREE TRIMMING
SUB-STA: NEPTUNE BEACH N.O.: 561 RECD:NO
CELL
ENGINEER:Robert Simpson N.O.: N/A ZIP CODE: NIA
CUSTOMER/ SVC PHONE
LOCATION: 89 W 2ND ST/50/2W AND TRANS INSTALL 561 CENTER: SSSC N.O.:665.7793
STA 1, P# 91 W. 2ND STI INSTALL 50/2W
-- AND 75KVA, RUN 4/OP TO STA 2. i
STA 2, P# 88 W 2ND ST./ REMOVE 410P TO \ p .�
STA 3.
STA 3, P#95 W 2ND ST. �•
9 NEW HOMES BUILD
OCAe�00
a
cv 1/0
• .� STA 3 STA 1 110-r
.� 98 6
N 97 4
l� \� 4t) v 93 89 92
.`v 87
® 85
ICD D
0
200 %r
-j -- i
0
25A �N`
CD �� 96 8� -)/Op
Imo' 0 4/1OP
8q 4/gyp
i 6 0 ^o 4/0
190 '; [STA 2 ,�� o�Z'• b
5OTCD
ro
-JE*A CUE Reports
Estimate Number:39549 89 W 2ND ST./50/2W AND TRANS Estimate Type:SR Contract:089-16-HM OH FY19
INSTALL
Estimate Version: By: SIMPRB
MWO#/Task:30462651 Required Date:
Oracle Project#:8005212 Estimated On: 07/31/2019
Cost Estimate
Materials JEA Contractor
1.New Material Cost(wl sales tax) $1,323.75 $1,323.75
2.Transformer Cost(w/sales tax) $1,980.44 $1,980.44
3.Returned Material Salvage Value $0.00 $0.00
Labor
4.Crew Time S938.80 $1,659.31
5.Extraordinary Costs $0.00 $0.00
JEA Overhead
6.Fringe Benefits(43.52%of lines 4&7) $522.76 $121.59
7.Engineering Costs(Variable%of line 4) $262.39 $279.40
8.Project Equipment Costs(40%of total equipment costs) $553.01 $0.00
9.Material Handling(6.67%of lines 1 &2) $220.39 $220.39
10.Inspection(6.84%of line 4) $0.00 $113.50
11.Total Cost of Project $5,801.54 $5,698.38
12.Work Order Estimate(Line 11 minus line 8,9,&10) $5,028.14 $5,477.99
13.Billable Equipment Depreciation(60%of total equipment costs) $829.52 $0.00
14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(64.49%of 4&7)) $7,405.72 $5,878.56
15.Billing Estimate(W/O Transformer Cost)(Lines 11+13+(64.49%of 4&7)-Line 2) $5,425.28 $3,898.13
Time Estimate
Crew Hours Total Manhours
7.53 30.11
---------------------------------------------------------------------------------------------------------------------------------
JEJV
CUE Reports
Estimate Number:39549 89 W 2ND ST./50/2W AND TRANS Estimate Type:SR Contract:089-16-HM OH FY19
INSTALL
Estimate Version: By: SIMPRB
MWO#/Task:30462651 Required Date:
Oracle Project M 8005212 Estimated On: 07/31/2019
CU Detail
Station: 01 91 W 2NO ST.
Build Transfer Remain in Place Remove
CAMP 75
DC1 F-5*2 1
DGAC*75 1
DHLC*1/0 3
G1 W*2 1
I.BAYSW004 1
P.50/2W 1
RUBDOWN 8
RUBUP 8
S4*4/0 1
S9*1/0 5
S9*4/0 2
Station;2 :: W 2ND ST.
Build Transfer Remain in Place Remove
GY3*5 1
S20ES*4/0-1/0 2
S20ES*410-4/0 1
S4*4/0 1
C.4/OP 75
POLECON 3
Station: 3
Build Transfer Remain in Place Remove
ARRESTER 1
BANK10 1
CUTOUT 1
POLECON 1
RUBDOWN 8
RUBUP 8
SWITCH 1
JE*1 CUE Reports
Estimate Number:39549 89 W 2ND ST./50/2W AND TRANS Estimate Type:SR Contract:089-16-HM OH FY19
INSTALL
Estimate Version: By: SIMPRB
MWO#/Task:30462651 Required Date:
Oracle Project#:8005212 Estimated On: 07/31/2019
Conductor, Conduit and Pipe Detail
Quantities
From Station To Station CU Build Transfer Remain Remove
01 2 CA10P 75 0 0 0
2 3 CAMP 0 0 0 75
-AF-A. CUE Reports
Estimate Number:39549 89 W 2ND ST./50/2W AND TRANS Estimate Type:SR Contract:089-16-HM OH FY19
INSTALL
Estimate Version: By: SIMPRB
MWO#/Task:30462651 Required Date:
Oracle Project#:8005212 Estimated On: 07/31/2019
Material Summary
Item Quantity Item Number Item Description
1 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZED 10"X 8' X 1-1/4", SHIP
ON OPEN FLATBED ONLYI
1 ARRL1003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER
POLE (MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL
VOLTAGE
1 BAYSWO04 BAYONET, SHIELD WIRE, STRAIGHT 40" LENGTH
1 BKTAC009 BRACKET, ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM
MATERIAL OVER ROD TYPE: SINGLE PHASE
3 BKTFS001 BRACKET, FIBERGLASS STANDOFF, 2" FIBERGLASS ROD, 18"
STANDOFF TO INS BASE ROD COVERED WITH RAYCHEM HEAT-
SHRINK MATERIAL, DUCTILE IRON FITTINGS
2 BOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV.WITH 4 SQUARE NUTS
ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25
EACH)
1 BOLDA016 BOLT, 3/4"X 16", DOUBLE ARMING, GALV. WITH 4 SQUARE NUTS
ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25
EACH)
4 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
4 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
1 BOLMS037 BOLT, MACHINE, 3/4"X 16", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
12 BOLTE001 BOLT,TERMINAL KIT, ( KIT INCLUDES ) 1-EACH 1/2" DIA.X 2"S/S
BOLT FULL THREAD,2-EACH S/S FLAT WASHERS, 1-EACH S/S
BELLEVILLE 1-SILICON BRONZE NUT( SHIPPED IN BAGS OF 10-EACH
ASSEMBLED )"(SEE SPECIFICATION)"
75 CA10SO03 CABLE,4/0-19(PAP),OVERHEAD SERVICE DROP, 600 VOLT
MULTIPLEX CABLE"VICKSBURG" PRE-ASSEMBLED PARALLEL 1000
FOOT REELS
1 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK"
3 CLAHL001 CLAMP, HOT LINE, 6-1/0-MAIN,6-1/0-TAP
1 CLASR002 CLAMP, STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP
4 CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:#6-2/0
2 CLASS006 CLAMP, STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM (STD
PKG 15 EA)
1 CLATGO01 CLAMP,TRANSFORMER TANK GROUND, "BRONZE"6 SOL-1 STR.
3 CNNCP002 CONNECTOR,#2, 6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION,
PARALLEL TAP,
10 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION,
PARALLEL TAP,ALUMINUM,
8 CNNCP006 CONNECTOR,46, 1/0-2/0 MAIN, 3/0-4/0 TAP COMPRESSION,
PARALLEL TAP, ALUMINUM,
-1E.*1 CUE Reports
Estimate Number:39549 89 W 2ND ST./50/2W AND TRANS Estimate Type:SR Contract:089-16-HM OH FY19
INSTALL
Estimate Version: By: SIMPRB
MWO#/Task:30462651 Required Date:
Oracle Project#:8005212 Estimated On: 07/31/2019
7 CNNCP007 CONNECTOR, #7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION,
PARALLEL TAP,ALUMINUM,
4 CNNCP008 CONNECTOR,#5, 6-2 MAIN,4/0 TAP, COMPRESSION, PARALLEL TAP,
ALUMINUM,
2 CNNGRO02 COUPLING, GROUND ROD, "THREADLESS"REMARKS: FOR
THREADLESS GROUND RODS
3 CNNTS006 CONNECTOR, TRANSFORMER SECONDARY SET SCREW TYPE
W/INHIBITOR,4-HOLE NEMA RANGE: 10-500, 3-PORTS.
4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE
36 COBCCO28 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON
PLASTIC REEL,4"X 11.5"W/2" HOLE
70 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD & COPPERWELD-
COPPER .204" DIAMETER 14804 BREAKING STRENGTH ( 50#COIL-
427' )
30 COVIC002 COVER, "D" DIE, INSULATING,2-1/2"
1 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE
TO GROUND, 100A, 27 KV, 170 KV BIL (54 EA PER PALLET)
1 FUSOH026 FUSE,OVERHEAD DISTRIBUTION, 5.2 AMP,TRANSFORMER.
1 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96",GRAY PLASTIC
1 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED
ON ALL 3/8"AND 7/16" GUY STRANDS (DISTRIBUTION)
1 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP
GALV. 13/16" MOUNTING HOLE,20,000 LB MIN. ULT. STRENGTH. FOR
WOOD OR CONCRETE POLES
2 GUYGR001 GRIP, GUY, 3/8", 26", GALVANIZED
50 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS
"B" GALV. OR BEZINOL IS ACCEPTABLE (500'COIL)
1 INSGB002 INSULATOR, STRAIN, GUY BREAKER, 21,000#RATED, 60" ROD
LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM
ONLY
2 INSS0002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#,
GALV. FITTINGS
3 INSVP001 INSULATOR, VERTICAL POST,TIE TOP 35-KV,3/4"STUD TAP
STANDARD PACKAGING IS NOT TO EXCEED THREE UNITS OR 72
POUNDS.
2 NUTSL003 NUT, LOCK, SQUARE, 5/8"HOLE SIZE, HOT DIPPED GALVANIZED
2 NUTSL004 NUT, LOCK,SQUARE, 3/4" BOLT SIZE, HOT DIPPED GALVANIZED
1 POLW0008 POLE,WOOD, 50'CLASS 2 (T/L= 18), WEIGHT=2,424 LBS
3 RODGRO03 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED
ONLYI
5 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL
SPLICING
2 SLEFT006 SLEEVE,4/0 7-STR AAAC, FULL-TENSION ALUMINUM, COMPRESSION
TYPE
3 STIC0001 STIRRUP, COMPRESSION, 2-1/0,ALUMINUM BODIES, COPPER BAIL,
BAIL SIZE-2-SOL
3 STUL1001 STUD, LINE POST, DIA. SHANK-3/4", SHANK LENGTH- 1-3/4",
GALVANIZED STEEL W/NUTS AND WASHERS; 3/4" HEAD SIZE
CUE Reports
Estimate Number:39549 89 W 2ND ST./50/2W AND TRANS Estimate Type:SR Contract:089-16-HM OH FY19
INSTALL
Estimate Version: By: SIMPRB
MWO#1Task:30462651 Required Date:
Oracle Project#:8005212 Estimated On: 07/31/2019
1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK
CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5'HIGH X 2"
WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG.
OF 50 EACH)
3 TIEPRO01 TIE, PREFORMED LINE, #2 AAAC,23" MIN. LENGTH, "F"NECK, SIDE
TIE .316"-.357" COND. RANGE
1 TRAC0003 TRANSFORMER, 75 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT
SECONDARY, SINGLE PHASE, CONTAMINATED ENVIRONMENT
2 WASRD004 WASHER, ROUND, 5/8"BOLT SIZE X 1 3/4" DIAMETER, GALVANIZED,
650 EA P/BOX)
18 WASRD005 WASHER, ROUND, 3/4" BOLT SIZE X 2"DIAMETER, GALVANIZED,**"
500 EACH PER BOX***
10 WASSF003 WASHER, SQUARE FLAT, 3" SQ X 1/4", 5/8"X 3/4" BOLT SIZE,
GALVANIZED
8 WASSP002 WASHER, SPRING, 3/4" BOLT SIZE, DOUBLE COIL HELICAL TYPE,
GALVANIZED(EXTRA HEAVY DUTY)
CUE Reports
Estimate Number:39549 89 W 2ND ST./50/2W AND TRANS Estimate Type:SR Contract:089-16-HM OH FY19
INSTALL
Estimate Version: By: SIMPRB
MWO#/Task:30462651 Required Date:
Oracle Project#:8005212 Estimated On: 07/31/2019
CU Summary
s,i« FyyC9y a Cy
19 D l n� Tu �} xr �P6 k�
,.w -1d.s.. �'n 1n
U Name ,Quantity Description
C.4/OP 75 4/0 AAC PAP W/4/0 AAAC NEUTRAL
DC1F-5*2 1 TANGENT TO 10 DEGREE ANGLE UNSHIELDED, CONTAMINATED
DGAC*75 1 TRANS; CI, 26AKV 120/240 75KVA
DHLC*1/0 3 1/0 JPT-LINE CLAMP FOR AERIAL CABLE
G1 W*2 1 WOOD POLE- EQUIPMENT GROUND
GY3*5 1 GY3*5 3/8"DOWNGUY W/8 FT SCREW ANCHOR
P.50/2W 1 50 FT. CLASS 2 WOOD POLE
RUBDOWN 8 LINE RUBBER REMOVAL, PER SECT.
RUBUP 8 LINE RUBBER INSTALLATION, PER SECT.
S20ES*4/0-1/0 4 SECONDARY CONNECTION AT POLE
S20ES*4/0-4/0 1 SECONDARY CONNECTION AT POLE
S4*4/0 2 SECONDARY DEADEND
S9*1/0 5 SECONDARY SPLICE
S9*4/0 2 SECONDARY SPLICE
w �+ - r`
F. e� EY4a± a.^.'.r
CU Name Quantity Description
ARRESTER 1 DIST.ARRESTER REMOVAL
BANK10 1 SINGLE TRANS. REMOVAL, UP TO 75KVA
C.4/OP 75 4/0 AAC PAP W/4/0 AAAC NEUTRAL
CUTOUT 1 FUSE CUTOUT REMOVAL
POLECON 4 S20 REMOVAL
RUBDOWN 8 LINE RUBBER REMOVAL, PER SECT.
RUBUP 8 LINE RUBBER INSTALLATION, PER SECT.
SWITCH 1 CUTOUT&ARRESTER BRKT. REMOVAL