2160 Fairway Villas Ln S RES19-0240DESIGN CRITERIA & LOADS 5TN CODE: 2017 FLORIDA BUILDING CODE- RESIDENTIAL, AND CURRENT REFERENCED CODES AND STANDARDS Rte_ LOADING LOAD TYPE/PLACEMENT ROOF (Cd = 1.25) ROOF DEAD LOAD 7 PSF (SHINGLES) ROOF LIVE LOAD 20 PSF WIND LOADING BASIC WIND SPEED (ASCE 7-10) 130 MPH EXPOSURE CATEGORY B DEFLECTION CRITERIA FRAMING TYPE LIVE LOAD TOTAL LOAD ROOF L/240 L/240 0.75" MAX DEFLECTION UNDER ANY CASE SCOPE OF SERVICE MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE FOR ANY OF THEM TO CONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT .DOCUMENTS. LIMITS OF STRUCTURAL ENGINEERING DESIGN RESPONSIBILITIES: THE ITEMS SPECIFICALLY DESIGNED BY THE STRUCTURAL ENGINEER ARE LIMITED TO THE FOLLOWING: STRUCTURE TO SUPPORT GRAVITY LOADS, RESIST UPLIFT, AND RESIST LATERAL LOADS, AND MAINTAIN CONTINUITY FROM THE STRUCTURE TO SOILS BELOW. ITEMS NOT DESIGNED INCLUDE, BUT NOT LIMITED TO, PRE-ENGINEERED TRUSS DESIGN, TRUSS -TO -TRUSS CONNECTIONS, OR ANY ARCHITECTURAL, MECHANICAL OR ELECTRICAL SYSTEM. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN/ INSTALLATION OF ALL WATER PROOFING. I IMPORTANT RENOVATION NOTE INFORMATION SHOWN ON THESE DRAWINGS REGARDING EXISTING CONDITIONS HAVE BEEN OBTAINED BASED ON AVAILABLE SOURCES AT THE TIME OF DESIGN INCLUDING ASSUMPTIONS BASED ON .EXPERIENCE WITH SIMILAR STRUCTURES. THE ACTUAL AS -BUILT CONDITION FOUND IN THE FIELD MAY VARY FROM INFORMATION INDICATED IN THESE DRAWINGS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY ENGINEER IN WRITING BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN THESE DRAWINGS AND/OR ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL REPAIR/REPLACE ANY DAMAGED EXISTING STRUCTURAL MEMBERS DISCOVERED DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING. CONSTRUCTION. SAFETY OF THE STRUCTURE AND PERSONNEL DURING CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. LTT20B 2.0 HEADER W/ ND (2)KINGS. PER 3/S2.0 OFFICE COPY REVIEWED FOR CODE COMPLIAN CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS LOCATION OF NEW OPENING IN EXTERIOR WALL REVIEWEDBY:_„.j2(/ DATE: '7' 7) 0 O \\U111111 ti 111l Ity�J' �. PoNr/,, ' z mm_ GEN 3 < o V X 4-4 4-0 ti Ln "* E OF 00 O dam' 00 Q > O U, N u r'rrnrrnuull`" c V) C ._j 0 Luis A Pontigo P5 r JUL2019 CD �? �✓ L1i �✓ w N r_4 C� I� O FL PE NO 53311 U z O r.., O 0 n Z O w� p0 LTT20B 2.0 HEADER W/ ND (2)KINGS. PER 3/S2.0 OFFICE COPY REVIEWED FOR CODE COMPLIAN CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS LOCATION OF NEW OPENING IN EXTERIOR WALL REVIEWEDBY:_„.j2(/ DATE: '7' 7) 0 v mm_ O N U Qi V X 4-4 4-0 ti Ln c: 00 O dam' 00 O U, N u c O ._j 0 mm_ 11/' „ 12d NAILS N FROM OTHER SIDE OF 2nd PLY. POST (3) 10d Q 12" OC EA. SIDE (2)2x - BEAM NOTES: 1. TYPICAL CONNECTION AT STUD COLUMNS, JACK -TO -KING ASSEMBLIES, CORNER POSTS, ETC. BUILT UP MEMBER FASTENING llls2.o NOTES: 1. SEE FIRST LEVEL FRAMING PLAN FOR ANCHOR LOCATIONS. 2. THE EMBEDMENT DEPTHS SHOWN ARE TYPICAL. GREATER EMBEDMENT DEPTHS MAY BE REQUIRED WHERE SHOWN ON PLAN (I.E. AT GARAGE RETURNS) 3. LTT20B HOLD DOWNS ARE ONLY REQUIRED TO BE RECESSED INTO SLAB WHERE FRAMING IS PACKED TIGHT AND PREVENTS INSTALLATION WITHIN THE WALL. LTT208 MAY BE REPLACED WITH DTT2Z IF THERE IS ADEQUATE ROOM IN THE WALL FOR INSTALLATION BASE ANCHOR SCALE: 3'4" = 1'-0" ALL NEW BUILT UP (MEMBER PLY'S SHALL BE FASTENED PER 1/S2.0 I EXISTING STUDS BECOME CRIPPLE STUDS. FASTEN TOP AND BOT W/ (2)12d TOENAILS ROOF FRAMING AND STRAPPING TO REMAIN AS IS (NOT SHOWN FOR CLARITY) --- EXISTING DOUBLE TOP NEW (2)2x8 SYP#2 HEADER PLATE TO REMAIN AS IS H2KING STUD -HEADER TO JACK TO W/ (1)MSTA24 TO TOP PLATE HEADER TO KING STUD NAILING:_,,'NEW t6'-0" OPENING (7)12d TOENAILS, EACH SIDE f - EXISTING 2x4 SPF#2 STUDS ® 16" OC TO REMAIN AS IS (ADD VERTICAL STUD ADJACENT TO EXISTING AS NEEDED FOR SHEATHING ATTACHMENT OR AS NEEDED FOR 2x4 ® 16" ON MAX STUD SPACING. 2)2x4 SYP#2 JACKS AND FASTEN TO EXISTING STUD PER 1/S2.0) 1,2)2x4 SYP#2 KING STUDS EXISTING 2x4 PT SOLE PLATE TO REMAIN AS IS -' KING STUD TO FOUNDATION W/ U SIMPSON LTT20B PER 2/S2.0 E)NEW OPENING ELEVATION 2.0 SCALE: 3/4' = 1'-O" EXISTING FOUNDATION` MIN (2) STUDS OR SCAB 36" STUD TO FULL HEIGHT STUD W/ (12) 10d RECESSED IN SLAB AS REQUIRED PER NOTE 3 MIN 4" Y"0 THREADED ROD OXIAP0x6EDTITEN HD OR SIMPSON LTT208 NEW EXTERIOR WALL SHEATHING_ MIN. 7/1e", 24/16, APA RATED OSB OR PLYWOOD SHEATHING, FASTENED W/ 8d 6" O.C. EDGE AND 6" O.C. FIELD.SHEATHING MAY BE ORIENTED VERTICALLY OR HORIZONTALLY. Luis A Pontigo PE JUL 2 3 2019 FL PF NO 53311 OFFICE COPY z V) j � Q V LL V N Z c: V Ln L✓ L LJCf1 V) O O U -i Q � O LJ,- CM�Q CJS 0 OC—�' r%" C-01 c--, M N ra0 u. V LU "i ti N e. a„ O U o 4w ° p z �a a n o o� M N �s � O N LL- M N t` :� c: V O U -i O cn Ln V) CM�Q 4-0 4-0 ra0 u. V c: Ki v u. 00 • �r V M V G1 00 rt 0 c W �s � LL-