1671 W Park Ter RES19-0156 Install Fireplace %» RESIDENTIAL PERMIT PERMIT NUMBER
r I ` CITY OF ATLANTIC BEACH RES19-0156
800 SEMINOLE ROAD ISSUED: 8/14/2019
ATLANTIC BEACH. FL 32233 EXPIRES: 2/10/2020
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL • ' K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' D+ BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
JOB ADDRESS: PERMITTYPE: DESCRIPTION: VALUE OF WORK:
1671 W PARK TER RESIDENTIAL ALTERATION install fireplace $2000.00
RESIDENTIAL
TYPE OF
ZONING: :D •
• • GROUP:
172020 0332 SELVA MARINA UNIT 07
COMPANY: ADDRESS: CITY: STATE: ZIP:
David Hacker 2546 S. Tabernacle PI Jacksonville FL
• ADDRESS:
JOSEPH & KATHERINE 1671 PARK TER W ATLANTIC BEACH FL 32233-5609
ALBERTI
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 45S-0000-322-1000 0 $65.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50
STATE DBPR SURCHARGE 45S-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 4S5-0000-208-0600 0 $2.00
TOTAL: $101.50
Issued Date:8/14/2019 1 of 2
Ys.ay; 3 City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
s
800 Seminole Road f
Atlantic Beach, Florida 32233-5445 C l
Phone(904)247-5826 - Fax(904)247-5845
E-mail: building-dept@coab.us Date routed: J !
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: Yl�� � '1'�l �"yr• J4gp@QnRnt review required Yes No
Building
Applicant: ��. "� �, Planning &Zoning
Tree Administrator
Project: t nS-rA�I 11 D�a�-� Public Works
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature Q,/
Other Agency Review or Permit Required Review or Receipt Date 1►_
of Permit Verified B K�
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants �L
Division of Alcoholic Beverages and Tobacco 0
Other:
APPLICATION STATUS
Reviewing Department First Review: Q proved. [-]Denied. ❑Not applicable
(Circle one.) Comments: /a,,+h d Y i Lq 4 )u,\ t g . 4v n, ri P cc)-cc) 'f yv w-,
BUILbame
PLA G &ZONING Reviewed by: Date: 26 �2v�
TREE ADMIN. Second Review: []Approved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
Building Permit Application
City of Atlantic Beach Building Department •"ALL INFORMATION
800 Seminole Roid, Atlantic Beach, FL 32233 HIGNIIGHTEDINGRAY
Phone: (904) 247-5826 Email: ``cit0ding,D(,Iltr,-z)aoab.us IS REQUIRED. (^
Job Address: y 4 �Uf t'U c G W BSk,Pto+hT i, 8GJ rf`L, 133 Permit Number:
I eg,al Desc•iption ��r�Q�alS-;q 56,x, 1�af�b Uin:t _ _L��'�` k _ _REd_.1.
Valuation of Work IReplacement Cost)$�, 5�►•�"3 Heated/Cooled SF Non-Heated/Cooled
• Class of Work: L.INPw L7Addition UAlteration L]Repalr OMove Memo OPool OWindow/Door
• Use of existing/proposed structure(s): CCommercial WResidential
• If an existing structure,is afire sprinkler system installed?: U'Ves CNo
a Will treefsl L`remuved in ds5otialior with proposed project?LYes must submit separate Tree Removal PermitdVo
Desc•be In detail the type of work to be performed:
Wood Burning Fireplace
SB80HB 42"Wood Burner white heringbone brick,UD4 fresh air kit.Chase cover G90 Gal
F or da Product Approva d _ _ for mu:tlple products use product approval form
Property Owner Information
Name Pit A-'k� t 'SDS �h M �� Address 3.�1_t.. p�y�-_ 'iraffUcc I.JLb� �-
City '<rh� Cin _... Phone --
E-Mail _w _
Ovrner or ARent(If Agent, Power of Attorney or Agency Letter Required)
Contractor Information
Name of Company ' 'Jn SQtc:o1}1ty 0; Ao*FL, Qualifying Agent__9
Address_�10 3�1 �taf g pTou- City state G Zip
Offiie Phone W-'1(1 051 lob Site Contact Nurnher qh u, 1 I
State Certification/Registration4 CRC 1330359 EMail
Architect Name&Phone d
Eng reer's Name P Phoned -----
Workers Compensation Insurer InBuramer_i_ca _—OR Exempt:-t Expiration Date 1/1/20
Application is hereby made to ubtain a permit to do the work and installatrons as indicated.I certify that no v,urk u,installation has
commenced priur to the issuance of a permit and that all work will be pe-formed to meet the standards of all the laws regulating
construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL.WORK,PLUMBING,SIGNS,
WEI.15,POOLS,FURNACES,BOILERS.HLATLRS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In additlon to the requirements of this
permit,there may be additional restrictions applicable to this property that may be fourd in the public records of tFis county,and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT I ce•tify that all the foregoing information is accurate and that all work will be doue in cornpliarce with all
applicable laws regulating construction and toning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR OTIC OF COMMENCEMENT.
�" ' of nc or Alli (Signature of Cantfaclorl j/_
Si ned and sworn o(to ffirl 1d)before is—/day of Signec and sworn to(of affirmed)before me this_L#day of
-
—'bY
b
( (Sig-at..re data^,} ;SiRnOturt of Notdryl
1�gl1tray
n rJ ! )Fertonelly Known OR c
I fica u„ ! IProducedtdenuficatian `•. 6_.1s^_�six,uat. rr
Tyn: ype of Identification:otaryPublic State of Floriharon Lynnette Rackleyy Commission GG 309833xpves 03/20/2023
Building pp Permit Application OFFICE COPY Updated 10/9/18
City of Atlantic Beach Building Department *"ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
Phone: (904) 247-5826 Email: Building-Dept@coab.�.as IS REQUIRED.
Job Address: I SP1 I Pare_ I if o—a���11-� �/�I 2 S� 06(o
Permit Number:_ Q S "t
Legal Description rJ� AO —cxJ L 1 V �h I� ✓t 'ACRE#
Ldh ` (j�—K 1
Valuation of Work(Replacement Cost $ c.�; Heated/Cooled SF ayyy Non-Heated/Cooled u0c-
• Class of Work: VNew ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Ni
• Use of existing/proposed structure(s): ❑Commercial MResidential RECEIVED
• If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No
• Will trees be removed in association with proposed ro'ect? Dyes must submit separate Tree Remoyoa 2rre V l a
lllyessctl
ribe in detail the type of work to be performed:
I OM of, ak VIa CIO,U, RI
Florida Product Approval# for multiple prodGtt)090p C , FL
Property Owner Information
Name Jbesp�l Address LLD-1I Rk�,� e-Krac- vuest
City State Zip 3 �_Phone
E-Mail
Owner or Agent(If Agent, Power of Attorney or Agency Letter Required)
Contractor Information
Name of Company DCC V J H(ACKC f Qualifying Agent
Address 96,J l to S 17AbC rY-U(,L PI ,(.1_ City J L1CK�CJn V ) I State F1_ Zip
Office Phone 01011 00 5jJ-;k Job Site Contact Number
State Certification/Registration# C f'_L I _S; D3 5ei E-Mail TMa, I (_Qt-y)
Architect Name&Phone#
Engineer's Name& Phone#
Workers Compensation Insurer 5(A ILA r)t2 r-i (V-_ �OR Exempt❑ Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and
there may be additional permits required from other governmental entities such as water management districts, state agencies,or
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING.C SULT WITH YOUR LENDER OR AN ATTO NEY BEFORE
RECORDING YOUR I O MENCEMENT.
49'01_ure owner or Agent) ( ' ature of Contractor)
Signed and sworn to(or affirmed)before me this ZC day of Signed and sworn to(or affirmed) before me this 20 day of
by Tl t t' YV -AlOv b UG- lei by 4�A 1 ✓kyhyAKLr
/
Sign re of Notary) '( gnatur of Notary)
ERTIFFANY HORNBAKTIFFANY HORN5AKER—I
,.
personally Known OR MY COMMISSION#GG 030650 Personally Known OR e _ MY COMMISSION#GG 030650
[ ]Produced Identification �..,d EXPIRES:September 15,2020 ]Produced Identification EXPIRES.September 15.2020
o' ` Bonded ThN Notary Public Underwriters Bonded Thru Notary Public UnderNmers
Type of Identification: I — ype of Identification.
Installation Manual
OFFICE COPY
Installation and Fireplace Setup
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
This fireplace uses SL1100 Series Chimney
2" CLEARANCE TO COMBUSTIBLES AND BUILDING INSULATION FROM CHIMNEY REQUIRED.
NOTICE: DO NOT discard this manual! A WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
I MAJESTIC damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
Model(s): DO NOT overfire. Overfiring will void your
U*
warranty.
SB60 C O ` us Comply with all minimum clearances to com-
rS B8 bustibles as specified. Failure to comply may
LISTEDcause house fire.
A WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
o Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
WOODBURNING FIREPLACE High temperatures may ignite clothing orotherflammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
Installation and service of this appliance should be performed by
qualified personnel.Hearth&Home Technologies recomends HHT
Factory Trained or NFI certified professionals.
NATIONAL A WARNING
hearth FIREPLACE
FACTORY TRAINING INSTITUTE' Fire Risk.
A CERTIFICATION AGENCY
For use with solid wood fuel only.
Other fuels may overtire and generate
REVIEWED FOR CODE COMPLIANCE poisonous gases(i.e.carbon monoxide).
CITY OF ATLANTIC BEACH
SEE PERMITS FOR ADDITIONAL
REGIUIUMENTS AND CONDITIONS
REVIEWED BY:_�DATE: 2 2f 2 O`0
Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18 1
Product Specific & Important Safety Information
A. Fireplace Certification B. Non-Combustible Materials
This fireplace system has been tested and listed in accor- Materials which will not ignite and burn, composed of
dance with UL 127 and ULC-S610 standards by Under- any combination of the following:
writers Laboratories Inc. for installation and operation in - Steel - Iron
the United States and Canada. - Brick - Tile
- Concrete - Slate
This fireplace may be installed in sleeping rooms. This - Glass - Plasters
fireplace is not approved for manufactured housing. If in- Materials reported as passing ASTM E 136, Standard
stalled with a gas log set, provisions for the National Fuel Test Method for Behavior of Metals,in a Vertical Tube
Gas Code must be met.
Furnace at 750° C
This fireplace has been tested and listed for use with
the optional components specified in this manual. These C. Combustible Materials
optional components may be purchased separately and Materials made of or surfaced with any of the following
installed at a later date. An outside air kit, gas insert, gas materials:
log set or gas log-lighter should be installed at the time of - Wood - Compressed paper
fireplace installation. - Plant fibers - Plastic
- Plywood/OSB - Sheet rock (drywall)
• Any material that can ignite and burn; flame proofed or
not, plastered or un-plastered
WARNING! Risk of Fire! Hearth & Home Technologies
disclaims any responsibility for, and the warranty and
agency listing will be voided by the following actions.
DO NOT.•
• install or operate damaged fireplace
• modify fireplace
• install other than as instructed by Hearth & Home
Technologies
• operate the fireplace without fully assembling all
components
• overfire
• install any component not approved by Hearth & Home
Technologies
• install parts or components not Listed or approved
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualified
installer, service agency or your dealer.
AWARNING: This product and the fuels
used to operate this product (wood and
wood pellets), and the products of com-
bustion of such fuels, can expose you to
chemicals including carbon black,which is
known to the State of California to cause
cancer and carbon monoxide, which is
known to the State of California to cause
birth defects or other reproductive harm.
For more information go to: www.P65Warn-
ings.ca.gov.
4 Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18
ZGetting Started
A. Typical Fireplace System
Additional lateral
support for chimney
above roof(or enclosed
in chase) if needed Termination cap
Storm Collar
Non-combustible
roof flashing maintains
minimum clearance Chimney penetrates roof
around chimney preferably without affecting
roof rafters
Support straps
on rafter support
chimney Offset& Return (with hanger straps)
Ceiling firestop Attic insulation shield
on floor of attic must be used here to keep
insulation away from chimney
if attic is insulated
Chimney system
Framing headed off
Combustible framing/head r in ceiling joists
on top of V-shaped stand s
Enclosed space above
and around fireplace
Chimney Air Kit
Required in Mantel and surround
Canada. Outlet
must be no
less than 4 ft. °
Decorative facing
(1.22 m) off
and trim
ground level.
Hearth extension
Outside
combustion air Factory-built fireplace
Protective metal
hearth strip(s)
Figure 2.1 Typical Fireplace System
Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18 5
B. Design and Installation Considerations Consideration should be given to these factors before
deciding on a location.
NOTICE: Check building codes prior to installation. NOTICE: In addition to these framing dimensions, also
• Installation MUST comply with local, regional, state and reference the following section:
national codes and regulations. • Clearances (Section 3).
• Consult insurance carrier, local building inspector, fire NOTICE:
officials or authorities having jurisdiction over restrictions, • Illustrations and photos reflect typical installations and
installation inspection and permits. are FOR DESIGN PURPOSES ONLY.
• Before installing, determine the following: • Illustrations/diagrams are not drawn to scale.
- Where the fireplace is to be installed. • Actual installation/appearance may vary due to individual
- The vent system configuration to be used. design preference.
- Gas supply piping. • Hearth &Home Technologies reserves the right to alter
- Electrical wiring. its products.
- Framing and finishing details. NOTICE:
- Whether optional accessories - devices such as a SB60-A minimum 1 in. air clearance at the back
fan, wall switch or remote control -are desired. and a minimum 1 in. air clearance to the sides of
1. Selecting Fireplace Locations the fireplace assembly must be maintained.
This fireplace may be used as a room divider, installed SB80-A minimum 1 1/2 in. air clearance at the
along a wall, across a corner or used in an exterior chase. back and a minimum 1 1/2 in. air clearance to the
See Figure 2.2. sides of the fireplace assembly must be main-
tained
Locating the fireplace in a basement, near frequently
opened doors, central heat outlets or returns, or other Chimney sections at any level require a 2
locations of considerable air movement can affect the in. minimum air space clearance between
performance. the framing and chimney sections.
IG
__ Note:SB60-1 in.(25 mm)
F SB80-1 1/2 in.(38 mm)
0 minimum distance from sides
&back of fireplace to
E
combustible materials.
\ Both- 1/2 in.(13 mm)
A minimum at nailing flanges.
B*
In an exterior H7TI * 8 in. (203 mm)extra space
Across a chase or projecting
comer included for outside air
A into a garage connection. If outside air duct has
no bend, this dimension may be
reduced as long as minimum
D C clearances are met.
Along a
4 wall H
A 1l2 in.(13 mm)
B A I all configurations
48 in.
(1219 mm) G
min.
H As a room
1 divider
Model A B c D E F G H
SB60 inches
mm 56 1 24 in.(610 mm)
Min
inches 51 112 591/2 92 314 463/8 21112 655/8 28 112 Minimum from perpendicular
opening to an
SB80 wall.
mm 1308 1511 2356 1178 546 1667 724
Figure 2.2 Fireplace Locations
6 Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18
F. Frame the Fireplace WARNING! Risk of Fire! Comply with all minimum clear-
ances specified.
NOTICE: Hearth extension design must be determined . SB60 - A minimum 1 in. (25 mm) air clearance must
before installation of fireplace. be maintained at the back and sides of the fireplace
If the fireplace is placed on the floor the maximum height assembly.
of a finished raised hearth is 7-5/8 in., if you want a • SB80-A minimum 1 1/2 in. (38 mm)air clearance must
higher raised hearth the fireplace must be placed on a be maintained at the back and sides of the fireplace
platform. assembly.
• Chimney sections at any level require a 2 in.(51 mm)
Figure 3.12 shows a typical framing (using 2 x 4 lumber) minimum air space clearance between the framing
of the fireplace, assuming combustible materials are and chimney section.
used.All required clearances to combustibles around the
fireplace must be adhered to. See Figure 3.3.Any fram- WARNING!Risk of Fire! You must comply with all
minimum airspace clearances to combustibles. DO NOT
ing across the top of the fireplace must be above the level
of the top standoffs. pack required air spaces with insulation or other materi-
als.
The finished cavity depth must be no less than:
CAUTION!Risk ofCuts/Abrasions. Wear protective gloves
• SB60 - 28 in. (711 mm) from the finished backwall to and safety glasses during installation. Sheet metal edges
the outside of front wall framing. are sharp.
• SB80 - 28 1/2 in. (724 mm)from the finished backwall
to the outside of front wall framing. WARNING!Risk of Fire!Prevent contact with sagging,
loose insulation.
DO NOT install header until the fireplace is in position. . DO NOT install against vapor barriers or exposed
insulation.
• Secure insulation and vapor barriers.
• Provide minimum airspace clearances at the sides and
back of the fireplace assembly.
17 in. mm)
framing.g..
NJd I�hL_
Fireplace must be set out
1/2 in 1/2 in. (13 mm)in front of
(13 mm) the face of the framing
material.
Header MUST NOT be notched!
Header will sit on C =extra space needed for outside air connection.
top of front stand If outside air duct has no bend, this dimension may be
offs after fireplace �r reduced as long as minimum clearances are met.
is installed. � C
A
Model A B* (4"duct)
SB60 in. 451/2 28 8
MM 1156 711 203
SB80 in. 511/2 281/2 8
mm 1308 724 203
* If interior of chase will be drywalled,add the thickness to
this measurement.
Figure 3.13 Framing the Fireplace
14 Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18
Place waterproof sealer
under each flange of the
termination cap and on
top of each screw to
Remove 2 screws ina on Ca help prevent leaks.
from front&bac
to lift the top off The last section of pipe
I 1 mus[stop between 2 in.
(51 mm)above top of
I I
I chase and 4-3/4 in.(121
Collar I I mm)below top of chase
2 in.(51 mm) I I
Minimum Height I I
Chase To 2 in.(51 mm)
4-3/4 in.(121 mm)
La
I Chi se
Pi
Figure 5.13 Installing a TCT1175 Terra Cotta Cap
Assemble
storm collar Termination
around extended Cap(riot shown)
termination cap
p1peCT
once cap is
installed.
Do NOT block
Caulk gaps between air holes
storm collar 8 pipe, Storm Collar
and storm cellar
8 chase top. 3 dip brackets.
SSP over chase cellar
and attach with screws
I I
provided.
I I The last section of pipe must stop
Collar I 1 between 2 in.(51 mm)above the
2m(51 mm) I I I I I I top of the chase and 4 3!4 In.(121
Minimum Height I I I 1 mm)below the top of the chase.
Cnase Top I 2 in.(51 mm)
I 11
44 In.(121 mm)
II Chase
I Chimney I
ipe II
Figure 5.14 Installing a DTO/DTS Decorative Termination Cap
26 Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18
B. Clearances Minimum Clearances to Combustibles
WARNING!Risk of Fire! WITHIN ENCLOSURE AREA
You must comply with all minimum air space clearances Fireplace to backwall (160) 1 in. (25 mm)
to combustibles as specified in Figure 3.3. DO NOT pack Fireplace to backwall (180) 1 1/2 in. (38 mm)
required air spaces with insulation or other materials. Fireplace to sidewall (160) 1 in. (25 mm)
Framing or finishing material used on the front of, or in
front of, the fireplace closer than the minimums listed must Fireplace to sidewall (180) 1 1/2 in. (38 mm)
be constucted entirely of non-combustible materials (i.e., Top standoffs to header 0 in. (0 mm)
steel studs, concrete board, etc.). Failure to comply may Door opening to sidewall 124 in. (610 mm)
cause fire. MANTEL
Mantel minimum height 12 in. (305 mm)
above opening
Maximum mantel depth 12 in. (305 mm)
Storm Collar
ooC1
l�
Roof Flashing
Shaded areas
represent
-0-2 in. (51 mm) min.
air space clearance
required around pipe
(attic) Attic
Insulation
Shield
(insulation)
(ceiling)
t--
Offset/Return(secured
2 in. (51 mm)min. with hanger straps)
(ceiling)
Ceiling Firestop ust have 2 in. (51 mm)
minimum clearance
to header
Adapter attached here(not shown)
Note: Chimney air kit and 11-10
0 in.to level in./279-254 mm adapter are
of standoffs not shown, but are required in
Canada.
m Clearance to back&
0
O sides of appliance
160- 1 in. (25 mm)
48 in.
1219 mm 180-1 1/2 in. (38 mm)
D 0 in. (except at nailing flanges
E to floor where it is 1/2 in.[13 mm))
0
U
Figure 3.3 Clearances to Combustible Materials
Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18 11
C. Construct the Chase
A chase is a vertical boxlike structure built to enclose the Round Termination Cap
fireplace and/or its vent system. Vertical chimneys that
run on the outside of a building must be installed inside a Storm Collar
Metal Chase Top
chase.
In cold climates, Hearth & Home Technologies recom- ceiling
mends that the chase be well insulated using batt type in- Firestop
sulation between the joists.
Construction of the chase may vary with the type of build-
ing. These instructions are not substitutes for the require-
ments of local building codes. Local building codes MUST
be checked.
Chases should be constructed in the manner of all outside False Ceiling
walls of the home to prevent cold air drafting problems.The
chase should not break the outside building envelope in attic
any manner.All outer walls need to be insulated. Tabs Insulation
Shield
Building codes require false ceiling and ceiling firestops/ Ceiling Insulation in the
attic shields at each floor of the chase or every 10 ft (3048 Firestop outside walls
mm) of clear space to control spread of fire. of the chase
I
Walls, ceiling, base plate and cantilever floor at the first False Ceiling False Ceiling
level of the chase should be insulated (see Figure 3.3.) Chimney
Vapor and air infiltration barriers should be installed in the
chase as per regional codes for the rest of the home. Ad-
ditionally, Hearth & Home Technologies recommends that Figure 3.4 Chase Assembly
the inside surfaces be drywalled and taped (or the use of WARNING! Risk of Fire! You must maintain a mini-
an equivalent method)for maximum air tightness.
mum 2 in. (51 mm) air space clearance to insula-
Holes and other openings should be caulked with high tem- tion and other materials surrounding the chimney
perature caulk or stuffed with unfaced fiber glass insulation. system.
• Insulation and other materials must be firmly secured to
WARNING! You must install false ceilings and ceil- prevent accidental contact with chimney system.
ing firestops at each floor of the chase or every 10 ft • The chase must be properly blocked to prevent blown
(3.05 m) to control spread of fire. insulation or other combustibles from entering and
making contact with fireplace or chimney.
WARNING! Risk of Fire! DO NOT seal area between fire • Failure to prevent contact between insulation or other
stop opening and chimney pipe except where they enter materials and chimney system may cause overheating
the attic or leave the warm air envelope of the home (use and fire.
600°F sealant).
• The chase is constructed using framing materials much Three examples of chase applications are shown in Fig-
the same as the walls in your home. A variety of siding ure 3.5.
materials may be used including brick, stone, veneer
brick, Or Standard siding materials. 1. Fireplace and chimney enclosed in an exterior chase.
2. Chimney offset through exterior wall and enclosed in chase.
• In constructing the chase, several factors must be 3. Chase constructed on roof.
considered:
All outside walls should be insulated.
- Maintain a 2 in. (51 mm)air space around the
chimney.
- The chase top must be constructed of non-
combustible material.
- In cold climates,a firestop spacer and attic insulation
shield should be installed in an insulated false ceiling
at the 8 ft. (2438 mm) level above the fireplace
assembly.This reduces heat loss through the chase.
- In cold climates, the walls of the chase should be
insulated to the level of the false ceiling as shown in 1 2 3
Figure 3.4. This will help reduce heat loss from the Figure 3.5 Chase Constructions
home around the fireplace.
12 Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18