1671 W Park Ter RES19-0156 Install Fireplace %» RESIDENTIAL PERMIT PERMIT NUMBER r I ` CITY OF ATLANTIC BEACH RES19-0156 800 SEMINOLE ROAD ISSUED: 8/14/2019 ATLANTIC BEACH. FL 32233 EXPIRES: 2/10/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL • ' K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' D+ BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMITTYPE: DESCRIPTION: VALUE OF WORK: 1671 W PARK TER RESIDENTIAL ALTERATION install fireplace $2000.00 RESIDENTIAL TYPE OF ZONING: :D • • • GROUP: 172020 0332 SELVA MARINA UNIT 07 COMPANY: ADDRESS: CITY: STATE: ZIP: David Hacker 2546 S. Tabernacle PI Jacksonville FL • ADDRESS: JOSEPH & KATHERINE 1671 PARK TER W ATLANTIC BEACH FL 32233-5609 ALBERTI WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 45S-0000-322-1000 0 $65.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50 STATE DBPR SURCHARGE 45S-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 4S5-0000-208-0600 0 $2.00 TOTAL: $101.50 Issued Date:8/14/2019 1 of 2 Ys.ay; 3 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) s 800 Seminole Road f Atlantic Beach, Florida 32233-5445 C l Phone(904)247-5826 - Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: J ! City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Yl�� � '1'�l �"yr• J4gp@QnRnt review required Yes No Building Applicant: ��. "� �, Planning &Zoning Tree Administrator Project: t nS-rA�I 11 D�a�-� Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Q,/ Other Agency Review or Permit Required Review or Receipt Date 1►_ of Permit Verified B K� Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants �L Division of Alcoholic Beverages and Tobacco 0 Other: APPLICATION STATUS Reviewing Department First Review: Q proved. [-]Denied. ❑Not applicable (Circle one.) Comments: /a,,+h d Y i Lq 4 )u,\ t g . 4v n, ri P cc)-cc) 'f yv w-, BUILbame PLA G &ZONING Reviewed by: Date: 26 �2v� TREE ADMIN. Second Review: []Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application City of Atlantic Beach Building Department •"ALL INFORMATION 800 Seminole Roid, Atlantic Beach, FL 32233 HIGNIIGHTEDINGRAY Phone: (904) 247-5826 Email: ``cit0ding,D(,Iltr,-z)aoab.us IS REQUIRED. (^ Job Address: y 4 �Uf t'U c G W BSk,Pto+hT i, 8GJ rf`L, 133 Permit Number: I eg,al Desc•iption ��r�Q�alS-;q 56,x, 1�af�b Uin:t _ _L��'�` k _ _REd_.1. Valuation of Work IReplacement Cost)$�, 5�►•�"3 Heated/Cooled SF Non-Heated/Cooled • Class of Work: L.INPw L7Addition UAlteration L]Repalr OMove Memo OPool OWindow/Door • Use of existing/proposed structure(s): CCommercial WResidential • If an existing structure,is afire sprinkler system installed?: U'Ves CNo a Will treefsl L`remuved in ds5otialior with proposed project?LYes must submit separate Tree Removal PermitdVo Desc•be In detail the type of work to be performed: Wood Burning Fireplace SB80HB 42"Wood Burner white heringbone brick,UD4 fresh air kit.Chase cover G90 Gal F or da Product Approva d _ _ for mu:tlple products use product approval form Property Owner Information Name Pit A-'k� t 'SDS �h M �� Address 3.�1_t.. p�y�-_ 'iraffUcc I.JLb� �- City '<rh� Cin _... Phone -- E-Mail _w _ Ovrner or ARent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company ' 'Jn SQtc:o1}1ty 0; Ao*FL, Qualifying Agent__9 Address_�10 3�1 �taf g pTou- City state G Zip Offiie Phone W-'1(1 051 lob Site Contact Nurnher qh u, 1 I State Certification/Registration4 CRC 1330359 EMail Architect Name&Phone d Eng reer's Name P Phoned ----- Workers Compensation Insurer InBuramer_i_ca _—OR Exempt:-t Expiration Date 1/1/20 Application is hereby made to ubtain a permit to do the work and installatrons as indicated.I certify that no v,urk u,installation has commenced priur to the issuance of a permit and that all work will be pe-formed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL.WORK,PLUMBING,SIGNS, WEI.15,POOLS,FURNACES,BOILERS.HLATLRS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In additlon to the requirements of this permit,there may be additional restrictions applicable to this property that may be fourd in the public records of tFis county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT I ce•tify that all the foregoing information is accurate and that all work will be doue in cornpliarce with all applicable laws regulating construction and toning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR OTIC OF COMMENCEMENT. �" ' of nc or Alli (Signature of Cantfaclorl j/_ Si ned and sworn o(to ffirl 1d)before is—/day of Signec and sworn to(of affirmed)before me this_L#day of - —'bY b ( (Sig-at..re data^,} ;SiRnOturt of Notdryl 1�gl1tray n rJ ! )Fertonelly Known OR c I fica u„ ! IProducedtdenuficatian `•. 6_.1s^_�six,uat. rr Tyn: ype of Identification:otaryPublic State of Floriharon Lynnette Rackleyy Commission GG 309833xpves 03/20/2023 Building pp Permit Application OFFICE COPY Updated 10/9/18 City of Atlantic Beach Building Department *"ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@coab.�.as IS REQUIRED. Job Address: I SP1 I Pare_ I if o—a���11-� �/�I 2 S� 06(o Permit Number:_ Q S "t Legal Description rJ� AO —cxJ L 1 V �h I� ✓t 'ACRE# Ldh ` (j�—K 1 Valuation of Work(Replacement Cost $ c.�; Heated/Cooled SF ayyy Non-Heated/Cooled u0c- • Class of Work: VNew ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Ni • Use of existing/proposed structure(s): ❑Commercial MResidential RECEIVED • If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No • Will trees be removed in association with proposed ro'ect? Dyes must submit separate Tree Remoyoa 2rre V l a lllyessctl ribe in detail the type of work to be performed: I OM of, ak VIa CIO,U, RI Florida Product Approval# for multiple prodGtt)090p C , FL Property Owner Information Name Jbesp�l Address LLD-1I Rk�,� e-Krac- vuest City State Zip 3 �_Phone E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company DCC V J H(ACKC f Qualifying Agent Address 96,J l to S 17AbC rY-U(,L PI ,(.1_ City J L1CK�CJn V ) I State F1_ Zip Office Phone 01011 00 5jJ-;k Job Site Contact Number State Certification/Registration# C f'_L I _S; D3 5ei E-Mail TMa, I (_Qt-y) Architect Name&Phone# Engineer's Name& Phone# Workers Compensation Insurer 5(A ILA r)t2 r-i (V-_ �OR Exempt❑ Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts, state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING.C SULT WITH YOUR LENDER OR AN ATTO NEY BEFORE RECORDING YOUR I O MENCEMENT. 49'01_ure owner or Agent) ( ' ature of Contractor) Signed and sworn to(or affirmed)before me this ZC day of Signed and sworn to(or affirmed) before me this 20 day of by Tl t t' YV -AlOv b UG- lei by 4�A 1 ✓kyhyAKLr / Sign re of Notary) '( gnatur of Notary) ERTIFFANY HORNBAKTIFFANY HORN5AKER—I ,. personally Known OR MY COMMISSION#GG 030650 Personally Known OR e _ MY COMMISSION#GG 030650 [ ]Produced Identification �..,d EXPIRES:September 15,2020 ]Produced Identification EXPIRES.September 15.2020 o' ` Bonded ThN Notary Public Underwriters Bonded Thru Notary Public UnderNmers Type of Identification: I — ype of Identification. Installation Manual OFFICE COPY Installation and Fireplace Setup INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. This fireplace uses SL1100 Series Chimney 2" CLEARANCE TO COMBUSTIBLES AND BUILDING INSULATION FROM CHIMNEY REQUIRED. NOTICE: DO NOT discard this manual! A WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property I MAJESTIC damage, personal injury, or death. • DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. Model(s): DO NOT overfire. Overfiring will void your U* warranty. SB60 C O ` us Comply with all minimum clearances to com- rS B8 bustibles as specified. Failure to comply may LISTEDcause house fire. A WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch glass o Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. WOODBURNING FIREPLACE High temperatures may ignite clothing orotherflammable materials. • Keep clothing, furniture, draperies and other flammable materials away. Installation and service of this appliance should be performed by qualified personnel.Hearth&Home Technologies recomends HHT Factory Trained or NFI certified professionals. NATIONAL A WARNING hearth FIREPLACE FACTORY TRAINING INSTITUTE' Fire Risk. A CERTIFICATION AGENCY For use with solid wood fuel only. Other fuels may overtire and generate REVIEWED FOR CODE COMPLIANCE poisonous gases(i.e.carbon monoxide). CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REGIUIUMENTS AND CONDITIONS REVIEWED BY:_�DATE: 2 2f 2 O`0 Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18 1 Product Specific & Important Safety Information A. Fireplace Certification B. Non-Combustible Materials This fireplace system has been tested and listed in accor- Materials which will not ignite and burn, composed of dance with UL 127 and ULC-S610 standards by Under- any combination of the following: writers Laboratories Inc. for installation and operation in - Steel - Iron the United States and Canada. - Brick - Tile - Concrete - Slate This fireplace may be installed in sleeping rooms. This - Glass - Plasters fireplace is not approved for manufactured housing. If in- Materials reported as passing ASTM E 136, Standard stalled with a gas log set, provisions for the National Fuel Test Method for Behavior of Metals,in a Vertical Tube Gas Code must be met. Furnace at 750° C This fireplace has been tested and listed for use with the optional components specified in this manual. These C. Combustible Materials optional components may be purchased separately and Materials made of or surfaced with any of the following installed at a later date. An outside air kit, gas insert, gas materials: log set or gas log-lighter should be installed at the time of - Wood - Compressed paper fireplace installation. - Plant fibers - Plastic - Plywood/OSB - Sheet rock (drywall) • Any material that can ignite and burn; flame proofed or not, plastered or un-plastered WARNING! Risk of Fire! Hearth & Home Technologies disclaims any responsibility for, and the warranty and agency listing will be voided by the following actions. DO NOT.• • install or operate damaged fireplace • modify fireplace • install other than as instructed by Hearth & Home Technologies • operate the fireplace without fully assembling all components • overfire • install any component not approved by Hearth & Home Technologies • install parts or components not Listed or approved Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your dealer. AWARNING: This product and the fuels used to operate this product (wood and wood pellets), and the products of com- bustion of such fuels, can expose you to chemicals including carbon black,which is known to the State of California to cause cancer and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to: www.P65Warn- ings.ca.gov. 4 Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18 ZGetting Started A. Typical Fireplace System Additional lateral support for chimney above roof(or enclosed in chase) if needed Termination cap Storm Collar Non-combustible roof flashing maintains minimum clearance Chimney penetrates roof around chimney preferably without affecting roof rafters Support straps on rafter support chimney Offset& Return (with hanger straps) Ceiling firestop Attic insulation shield on floor of attic must be used here to keep insulation away from chimney if attic is insulated Chimney system Framing headed off Combustible framing/head r in ceiling joists on top of V-shaped stand s Enclosed space above and around fireplace Chimney Air Kit Required in Mantel and surround Canada. Outlet must be no less than 4 ft. ° Decorative facing (1.22 m) off and trim ground level. Hearth extension Outside combustion air Factory-built fireplace Protective metal hearth strip(s) Figure 2.1 Typical Fireplace System Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18 5 B. Design and Installation Considerations Consideration should be given to these factors before deciding on a location. NOTICE: Check building codes prior to installation. NOTICE: In addition to these framing dimensions, also • Installation MUST comply with local, regional, state and reference the following section: national codes and regulations. • Clearances (Section 3). • Consult insurance carrier, local building inspector, fire NOTICE: officials or authorities having jurisdiction over restrictions, • Illustrations and photos reflect typical installations and installation inspection and permits. are FOR DESIGN PURPOSES ONLY. • Before installing, determine the following: • Illustrations/diagrams are not drawn to scale. - Where the fireplace is to be installed. • Actual installation/appearance may vary due to individual - The vent system configuration to be used. design preference. - Gas supply piping. • Hearth &Home Technologies reserves the right to alter - Electrical wiring. its products. - Framing and finishing details. NOTICE: - Whether optional accessories - devices such as a SB60-A minimum 1 in. air clearance at the back fan, wall switch or remote control -are desired. and a minimum 1 in. air clearance to the sides of 1. Selecting Fireplace Locations the fireplace assembly must be maintained. This fireplace may be used as a room divider, installed SB80-A minimum 1 1/2 in. air clearance at the along a wall, across a corner or used in an exterior chase. back and a minimum 1 1/2 in. air clearance to the See Figure 2.2. sides of the fireplace assembly must be main- tained Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other Chimney sections at any level require a 2 locations of considerable air movement can affect the in. minimum air space clearance between performance. the framing and chimney sections. IG __ Note:SB60-1 in.(25 mm) F SB80-1 1/2 in.(38 mm) 0 minimum distance from sides &back of fireplace to E combustible materials. \ Both- 1/2 in.(13 mm) A minimum at nailing flanges. B* In an exterior H7TI * 8 in. (203 mm)extra space Across a chase or projecting comer included for outside air A into a garage connection. If outside air duct has no bend, this dimension may be reduced as long as minimum D C clearances are met. Along a 4 wall H A 1l2 in.(13 mm) B A I all configurations 48 in. (1219 mm) G min. H As a room 1 divider Model A B c D E F G H SB60 inches mm 56 1 24 in.(610 mm) Min inches 51 112 591/2 92 314 463/8 21112 655/8 28 112 Minimum from perpendicular opening to an SB80 wall. mm 1308 1511 2356 1178 546 1667 724 Figure 2.2 Fireplace Locations 6 Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18 F. Frame the Fireplace WARNING! Risk of Fire! Comply with all minimum clear- ances specified. NOTICE: Hearth extension design must be determined . SB60 - A minimum 1 in. (25 mm) air clearance must before installation of fireplace. be maintained at the back and sides of the fireplace If the fireplace is placed on the floor the maximum height assembly. of a finished raised hearth is 7-5/8 in., if you want a • SB80-A minimum 1 1/2 in. (38 mm)air clearance must higher raised hearth the fireplace must be placed on a be maintained at the back and sides of the fireplace platform. assembly. • Chimney sections at any level require a 2 in.(51 mm) Figure 3.12 shows a typical framing (using 2 x 4 lumber) minimum air space clearance between the framing of the fireplace, assuming combustible materials are and chimney section. used.All required clearances to combustibles around the fireplace must be adhered to. See Figure 3.3.Any fram- WARNING!Risk of Fire! You must comply with all minimum airspace clearances to combustibles. DO NOT ing across the top of the fireplace must be above the level of the top standoffs. pack required air spaces with insulation or other materi- als. The finished cavity depth must be no less than: CAUTION!Risk ofCuts/Abrasions. Wear protective gloves • SB60 - 28 in. (711 mm) from the finished backwall to and safety glasses during installation. Sheet metal edges the outside of front wall framing. are sharp. • SB80 - 28 1/2 in. (724 mm)from the finished backwall to the outside of front wall framing. WARNING!Risk of Fire!Prevent contact with sagging, loose insulation. DO NOT install header until the fireplace is in position. . DO NOT install against vapor barriers or exposed insulation. • Secure insulation and vapor barriers. • Provide minimum airspace clearances at the sides and back of the fireplace assembly. 17 in. mm) framing.g.. NJd I�hL_ Fireplace must be set out 1/2 in 1/2 in. (13 mm)in front of (13 mm) the face of the framing material. Header MUST NOT be notched! Header will sit on C =extra space needed for outside air connection. top of front stand If outside air duct has no bend, this dimension may be offs after fireplace �r reduced as long as minimum clearances are met. is installed. � C A Model A B* (4"duct) SB60 in. 451/2 28 8 MM 1156 711 203 SB80 in. 511/2 281/2 8 mm 1308 724 203 * If interior of chase will be drywalled,add the thickness to this measurement. Figure 3.13 Framing the Fireplace 14 Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18 Place waterproof sealer under each flange of the termination cap and on top of each screw to Remove 2 screws ina on Ca help prevent leaks. from front&bac to lift the top off The last section of pipe I 1 mus[stop between 2 in. (51 mm)above top of I I I chase and 4-3/4 in.(121 Collar I I mm)below top of chase 2 in.(51 mm) I I Minimum Height I I Chase To 2 in.(51 mm) 4-3/4 in.(121 mm) La I Chi se Pi Figure 5.13 Installing a TCT1175 Terra Cotta Cap Assemble storm collar Termination around extended Cap(riot shown) termination cap p1peCT once cap is installed. Do NOT block Caulk gaps between air holes storm collar 8 pipe, Storm Collar and storm cellar 8 chase top. 3 dip brackets. SSP over chase cellar and attach with screws I I provided. I I The last section of pipe must stop Collar I 1 between 2 in.(51 mm)above the 2m(51 mm) I I I I I I top of the chase and 4 3!4 In.(121 Minimum Height I I I 1 mm)below the top of the chase. Cnase Top I 2 in.(51 mm) I 11 44 In.(121 mm) II Chase I Chimney I ipe II Figure 5.14 Installing a DTO/DTS Decorative Termination Cap 26 Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18 B. Clearances Minimum Clearances to Combustibles WARNING!Risk of Fire! WITHIN ENCLOSURE AREA You must comply with all minimum air space clearances Fireplace to backwall (160) 1 in. (25 mm) to combustibles as specified in Figure 3.3. DO NOT pack Fireplace to backwall (180) 1 1/2 in. (38 mm) required air spaces with insulation or other materials. Fireplace to sidewall (160) 1 in. (25 mm) Framing or finishing material used on the front of, or in front of, the fireplace closer than the minimums listed must Fireplace to sidewall (180) 1 1/2 in. (38 mm) be constucted entirely of non-combustible materials (i.e., Top standoffs to header 0 in. (0 mm) steel studs, concrete board, etc.). Failure to comply may Door opening to sidewall 124 in. (610 mm) cause fire. MANTEL Mantel minimum height 12 in. (305 mm) above opening Maximum mantel depth 12 in. (305 mm) Storm Collar ooC1 l� Roof Flashing Shaded areas represent -0-2 in. (51 mm) min. air space clearance required around pipe (attic) Attic Insulation Shield (insulation) (ceiling) t-- Offset/Return(secured 2 in. (51 mm)min. with hanger straps) (ceiling) Ceiling Firestop ust have 2 in. (51 mm) minimum clearance to header Adapter attached here(not shown) Note: Chimney air kit and 11-10 0 in.to level in./279-254 mm adapter are of standoffs not shown, but are required in Canada. m Clearance to back& 0 O sides of appliance 160- 1 in. (25 mm) 48 in. 1219 mm 180-1 1/2 in. (38 mm) D 0 in. (except at nailing flanges E to floor where it is 1/2 in.[13 mm)) 0 U Figure 3.3 Clearances to Combustible Materials Majestic Biltmore Series • SB60/SB80 •4013-300 Installers Manual • Rev G • 09/18 11 C. Construct the Chase A chase is a vertical boxlike structure built to enclose the Round Termination Cap fireplace and/or its vent system. Vertical chimneys that run on the outside of a building must be installed inside a Storm Collar Metal Chase Top chase. In cold climates, Hearth & Home Technologies recom- ceiling mends that the chase be well insulated using batt type in- Firestop sulation between the joists. Construction of the chase may vary with the type of build- ing. These instructions are not substitutes for the require- ments of local building codes. Local building codes MUST be checked. Chases should be constructed in the manner of all outside False Ceiling walls of the home to prevent cold air drafting problems.The chase should not break the outside building envelope in attic any manner.All outer walls need to be insulated. Tabs Insulation Shield Building codes require false ceiling and ceiling firestops/ Ceiling Insulation in the attic shields at each floor of the chase or every 10 ft (3048 Firestop outside walls mm) of clear space to control spread of fire. of the chase I Walls, ceiling, base plate and cantilever floor at the first False Ceiling False Ceiling level of the chase should be insulated (see Figure 3.3.) Chimney Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Ad- ditionally, Hearth & Home Technologies recommends that Figure 3.4 Chase Assembly the inside surfaces be drywalled and taped (or the use of WARNING! Risk of Fire! You must maintain a mini- an equivalent method)for maximum air tightness. mum 2 in. (51 mm) air space clearance to insula- Holes and other openings should be caulked with high tem- tion and other materials surrounding the chimney perature caulk or stuffed with unfaced fiber glass insulation. system. • Insulation and other materials must be firmly secured to WARNING! You must install false ceilings and ceil- prevent accidental contact with chimney system. ing firestops at each floor of the chase or every 10 ft • The chase must be properly blocked to prevent blown (3.05 m) to control spread of fire. insulation or other combustibles from entering and making contact with fireplace or chimney. WARNING! Risk of Fire! DO NOT seal area between fire • Failure to prevent contact between insulation or other stop opening and chimney pipe except where they enter materials and chimney system may cause overheating the attic or leave the warm air envelope of the home (use and fire. 600°F sealant). • The chase is constructed using framing materials much Three examples of chase applications are shown in Fig- the same as the walls in your home. A variety of siding ure 3.5. materials may be used including brick, stone, veneer brick, Or Standard siding materials. 1. Fireplace and chimney enclosed in an exterior chase. 2. Chimney offset through exterior wall and enclosed in chase. • In constructing the chase, several factors must be 3. Chase constructed on roof. considered: All outside walls should be insulated. - Maintain a 2 in. (51 mm)air space around the chimney. - The chase top must be constructed of non- combustible material. - In cold climates,a firestop spacer and attic insulation shield should be installed in an insulated false ceiling at the 8 ft. (2438 mm) level above the fireplace assembly.This reduces heat loss through the chase. - In cold climates, the walls of the chase should be insulated to the level of the false ceiling as shown in 1 2 3 Figure 3.4. This will help reduce heat loss from the Figure 3.5 Chase Constructions home around the fireplace. 12 Majestic Biltmore Series • SB60/SB80 • 4013-300 Installers Manual • Rev G • 09/18