Loading...
1611 Ocean Blvd ROOF19-0066 Replacing w/Mod �•S'->>�r�, ROOF NON SHINGLE PERMIT PERMIT NUMBER ROOF19-0066 CITY OF ATLANTIC BEACH ISSUED: 8/21/2019 800 SEMINOLE ROAD EXPIRES: 2/17/2020 ATLANTIC BEACH. FL 32233 MUST CALL INSPECTION • ! • 1 BY 4 PM FOR NEXT DAY INSPECTION. CODE,ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDIN ' OF • OF ORDINANCES . ALL ! / ! OF PERMIT • • PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1611 OCEAN BLVD ROOF NON SHINGLE REPLACING SHINGLE WITH $12500.00 MOD ROOFING TYPE OF ZONING: : t • • • GROUP: 169555 0000 OCEAN GROVE UNIT 01 COMPANY: ADDRESS: ' BRC Roofing & 3938-1 Sunbeam Road JACKSONVILLE FL 32257 Construction, Inc. • ADDRESS: MORGAN GROVE 1659 HERTFORD RD CHARLOTTE NC 28207 PROPERTIES LLC WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. !Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $115.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50 BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.34 Issued Date: 8/21/2019 1 of 2 ROOF NON SHINGLE PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROOF19-0066 ISSUED: 8/21/2019 800 SEMINOLE ROAD EXPIRES: 2/17/2020 `�Oi31�r ATLANTIC BEACH. FL 32233 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.23 TOTAL: $228.07 Issued Date:8/21/2019 2 of 2 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road /_ j �� Atlantic Beach, Florida 32233-5445 0 _ Go& Phone(904)247-5826 • Fax(904)247-5845 � z� 1 ILE-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �, CC�ri`-� ULI� Department review required Yes No uildin Applicant: �� `\ C �G��►�(; £ ��(u;7 Planning &Zoning -N\, Ro Tree Administrator Project: I , D r l (�C Public Works V� Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date:2')-7 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 r� vJ CITY OF ATLANTIC BEACH "V 800 SEMINOLE ROAD r ATLANTIC BEACH, FL 32233 .. yr (904) 247-5800 BUILDING REVIEW COMMENTS Date: 7/29/2019 Permit#: ROOF19-0066 Site Address: 1611 OCEAN BLVD Review Status: Denied REM 169555 0000 Applicant: BRC Roofing& Construction, Inc. Property Owner: MORGAN GROVE PROPERTIES LLC Email:Jerry@BRCRoof.com Email: ccaldwell3@me.com Phone: 9042880431 Phone: 7049533169 9044632952 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. The Evaluation Report submitted is out dated, 12/07/09. The newer revision is needed, dated 4/11/2019, by different authorizing agent,NEMO/etc. 2 copies are needed. 2. Please only submit the information pages that will aid the inspector in identifying the products that are site specific for this job. In the report there are 69 pages. Do not submit 69 pages. Of those pages submitted,please high light the system to be used, material reference page, and the attachment process. 2 copies. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us Ernof f-ed 0-rvlews -7 / Z'7/ 1'7 `'l" Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which Building Permit Application Updoted10/9/18 -= _ City of Atlantic Beach Building Department "ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY n ih r�c IS REQUIRED. Phone: (904) 247-5826 Email: �uiiu+++;; �,`"_�_, 4VuU.�.� "7 C _ Job Address: 1611 Ocean Blvd.,Atlantic Beach, FL 32233 Permit Number: �cU�_� Legal Description 15-82 09-2S-29E OCEAN GROVE UNIT 1 S/D PT LOT 7 LOTS 15,16 BLK 1 RE# 169555-0000 Valuation of Work(Replacement Cost) 512.500.00 Heated/Cooled SF 3152 Non-Heated/Cooled 448 • Class of Work: ❑New ❑Addition ❑Alteration KIRepair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial klResidential • If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No • Will trees be removed in association with proposed project? ❑Yes must submit separate Tree Removal Permit ❑No Describe in detail the type of work to be performed: , Roof Replacement C� yyp }�.fj� Ga ry���S �c✓ Florida Product Approval # f=I )(v'e`t^/2-;Z if for multiple products use product approval form Property Owner Information Name Morgan Grove Properties LLC Address 1659 Hertford Rd. City Charlotte State NC Zip 28207 Phone 704-953-3169 E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company BRC Roofing &Construction, Inc. Qualifying AgentDarr'Rnwp Address 3938-1 Sunbeam Rd- City larksonvilla State FL Zip 32257 Office Phone 904-288-0431 Job Site Contact Number 904-463-2952 State Certification/Registration# CCC056398 E-Mail Jerry(d)brcroof.com Architect Name& Phone# Engineer's Name& Phone# Workers Compensation Insurer Zurich America OR Exempt❑ Expiration Date 1?f31/7019 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TOO IN FINANCING, CONSUL 9TH YOUR LENDER OR AN ATTORNEY BEFORE RE R NO O ENCEMENT. (Signa ur ner or Agent) (Signature of Contractor) { Signed and sworn to(or affirmed) befor me this qday of Signed and sworn to(or affirmed)before me this day of d� 14 ,o� by 'n a i cd� 1 �Nc ' ;Z c by TES ' v 'E (Sigr1ature of Notary) nature of Notary Public State of Florida Luz Mery Kraemer NO* S.Brian Hynes ( )Personally Known OR � Myersonally Known OR . • Cortxnission GG 152663 Produced Identification NOTARY PUBLIC Produced Identification ( ) ON Mecklenburg County,NC PJC D �d Expires 12/17/2021 r........t id,.,,.a:�...:,.... vno of Irfontifi�atinn• My Commission Expires September 7,2020 Doc (I 2019170713, OR BK 18872 Page 1852, Number Pages: 1 , Recorded 07/22/2019 06:10 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 Arm,/ NOTICE OF COMMENCEMENT State of Ftodda ill Tax Folio No.168855.0 W County of Duval To Whom R May Concern: The undersigned hereby informs you that Improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the follordng Infortnadon Is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being Improved:15.82 d9 28.29E OCEAN GROVE UNIT I SID PT LOT 73 LOTS 15,18 BLK 1 Address of property being improved:toll on"WWI. General description of improvements:Root Repktoemwd Owner Morges amn Propwon LLC Address:111158 fledb Rd.Charlotte.NC 26207 0 wr Ws Interest in site of the improvement:Fee Fee Simple Titleholder(if other than owner): Name. Contractor.DRC Fballnp i Cansb+ocam%tri. Adder.38311-1 Sunbeam Rd.,Jecloorrvlie,FL 12257 Telephone No.:(904)2N-0431 Fax No:(mo)292-OM Surety(If any) Address: Amount of Bond S Telephone No: Fax No: Name and address of any person making a loon for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served.Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the uerwes Notice as provided in Section 713.06(2)(b),Florida Statues. (FRI in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(tire expiration date is one(1)year from the date of recording unless a different date is Specified): TIM SPACE fOl!RECORDER'S USE ONLY OWNER signed: tate: 2.;) 11 Before me thio day of lathe County of Of FWWe,has personally appeared Notary Mrbtk at tar^State of Florula, Duvall. My Commkdon I FI- 217 WZ-4 - Personally Knower LLIZ M81Y KJWW or ProducedIkwMcadoa Pu" Wcldenburg Cmft NC My Commisri5n E);!res September 7,2020 Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. i 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: i�r ❑ Revision to Issued Permit OR Corrections to Comments Date: T• Project Address: r(e /l 0 ced.-^ /-3(V d Contractor/Contact Name: GCC OA"4- Se-jya `2ec�-C- Contact Phone: qo L4- t f(o 3 -2-Q 5�� Email: Te f ZJ�Z(ja 612G/'ye Description of Proposed Revision/Corrections: c> i 4.1 �"aCyGe i°a�u/'jZe s ke tee-ell S-7� H141-C tr C-0— .fie I---c 4lW affirm the revision/correction to comments is inclusive�ht fctivggs� (p anted name) [[„,��,, \\�,//// • Will proposed revision/corrections add additional square footage to original submittal? ,2No ❑ Yes (additional s.f.to be added: ) JUL 3 U 2019 • Will proposed revision/corrections add additional increase in building value to original sub M fl9in9 Department o El*Yes (additional increase in building value:$ ) (cont r� ryiUf'�ldllllli1Daeat��l, FL of Contractor/Agent: C ,, J (Office Use Only) V t Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ C)66 Revision/Plan Review Comments Deoartment Review Required: Building fanning&Zoning U Reviewed By Tree Administrator Public Works Public Utilities l Public Safety Date Fire Services Updated 10/17/18 POLYFRESKO@ G SA OFFICE COPY HIGHLY REFLECTIVE SELF-ADHERED APP CAP SHEET PRODUCT DESCRIPTION Polyfresko G SA is a highly reflective,self-adhered granular surfaced atactic polypropylene(APP)modi- fied bitumen roofing membrane manufactured using patentedADESU®DuaFCompoundSelf-Adhesive y technology whereby a "true" APP compound is applied on the top layer and an aggressive self-adhesive compound on the bottom. Polyfresko G SA membrane performs to Energy Star® standards for reflectivity, is a Califor- nia Title 24 compliant membrane, achieves Class A fire rating and has been tested to ensure long-term performance in the most extreme environments. Polyfresko G SA membrane is listed with the Cool Roof Rating Council(CRRC)with a Solar Reflectance Index(SRI)of 96. Polyfresko G SA membrane features CURE Technology® - an innovative thin film technology attributing to exceptional granule retention, stain and discoloration resistance and UV ®.40ES0 OCU1Ze stabilization for long term durability and performance. CURE Technology is solvent-free and envi- -•••• Meftnoroyv ronmentally friendly. PRODUCT DATA Polyfresko G SA is constructed with a high performance polyester reinforcement providing a roof Coverage(Approx).......... .......... 100 sq ft ing membrane with exceptional tensile strength and dimensional stability. Polyfresko G SA features . .. patented Fastlap® for granule free roll ends, as well as Seallap®, a factory applied adhesive Weight(Approx)............................ s 160 mi treatment at the membrane overlap. Each of these patented features provide for greater ease of Thickness(Nominal) .........4.0 mm; mils application as well as improved product performance. Roll Size ....... 32'10'..39 / I l Omm x mx 1 m) Rolls/Palleett.............................................20 TYPICAL APPLICATIONS • Designed for applications where using a propane torch is undesirable or prohibited • For application directly over acceptable substrates and/or part of a multiply roof system APPLICABLE STANDARDS • Ideal for new roofing, re-roofing or for flashing detail • ASTM D6222 Type I,Table 1 FEATURES AND BENEFITS UL Classified for use in class A, B or C • Suitable for most cool roof specifications; SRI value of 96 roofs,as listed in the latest UL"Roofing • Premium membrane construction for exceptional durability and puncture resistance Materials and Systems Directory' • Exceptional granule retention and stain resistance • Miami Dade Code Compliance • ICC ESR-2018 TECHNICAL DESCRIPTION • CRRC listed • FBC TEST OF "O. • pTDI ICC ASTM D5147 Peak Load @ 23+/2C J73.4+/-3.6F), MD 8.8 (50) ��Ilif-CON�FS� `tri and XMD, min, kN/m (Ibf/in.) ASTM D5147 Elongation @ 23+/-2C(73.4+/-3.6F), MD 23 and XMD, min(%) ASTM D5147 Tear Strength @ 23+/-2C (73.4+/-3.6F), 311 (70) min, N(Ibf) ASTM D5147 Low Temperature Flexibility, max, C(F) 0(32) PRODUCT WARRANTY ASTM D5147 Granule Embedment, g 2 Poly ss U.S.A., Inc. commercial roofing membranes can be backed with a manufacturer's ASTM D1970 Adhesion to Plywood @ 40°F, min, Ibf/ft width 2.0 warranty for up to 20 years when used as part rove ASTM D 1970 Adhesion to Plywood @ 75°F, min, Ibf/ft width 12.0 of an app r Polygd,multiply roofing system.Please see your lyglass U.S.A., Inc. Sales or Technical ASTM D1970 Sealability around nail pass Representative for specifications and details. ASTM D1970 Waterproof integrity after low temp flexibility pass ASTM D 1970 Waterproof integrity of lap seam pass ROOFING.AND WATERPROOFING SYSTEMS AVAILABLE COLOR 1 ;101 N'llccj Highly Reflective white EVIEWED FOR CODE COMPLIANCE IB MAXI CITY OF ATLANTIC BEACH www.Polyglass.us opyngh'©tot 6 by Potyglass U S A,Inc and all rights ore s�PERMITS FOR ADDITIONAL Edition D•N:09/16. . � o a s� REQUIREMENTS AND CONDITIONS OFFICE COPY REVIEWED BY- /� '�/' nnrc. POLYFRESKOO G SA HIGHLY REFLECTIVE SELF-ADHERED APP CAP SHEET APPLICATION INSTRUCTIONS Polyfresko G SA is intended to be used as a cap sheet for new or re-roof oppplicatio is as part of a multiply system when applied to accepttable insulations and/or coverboards for commercial and residential structures. Polyfresko G SA may also be applied directly to approved w0000dd deck substrates of non-occupied spaces such as carports, sheds, canopies, etc. • Apply only when the weather and forecast is dry and the ambient air temperature and substrate is 40aF(5aC)and rising. • Apply over clean, dry,dust and debris-free substrates. Prime concrete decks prior to application with PG 100 Asphalt Primer. • When reroofing, remove all prior roofing materials down to a clean debris-free substrate and properly close-off all abandoned roof penetrations. • Concrete or steel decks shall be designed with proper expansion devices. • Wood decks shall have all joints blocked and/or properly supported as required by Code. • Ensure the installation of Polyfresko G SA does not prevent the ventilation of existing construction. • Do not apply over shingles or other granulated surface. • While installing Polyfresko G SA: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Start by removing the first 18-24"of release film. 4. Press the membrane into place with firm and even pressure. Roll the edges with a silicone hand roller to ensure complete adhesion. 5. Gradually remove the remaining release film applying pressure from the center to the edges as you go. 6. Position successive rolls providing a minimum 6"end lap and 4"side lap. End laps or any lap of the adhesive backside to the reflective surface to be sealed using a hot-air welder or flameless torch. Ensure a watertight seal. 7. All flow at seams to have granule broadcast into the molten compound. Using the Polyglass Detail& Repair Finish to cover the granules for a uniform reflective appearance. 8. After installation of the entire roof surface, roll with an 80# split-face linoleum roller. Take care on sloped roofs by securing the roller and applicator with the appropriate safety equipment. • Details and flashing may be installed using Polyfresko G SA with a hot air welder or with PG 500 Roof Cement. Check project details for proper installation requirements. • Use Polyglass Detail&Repair Finish to treat seams on Polyfresko G SA cap sheet. For more information, refer to the Polyglass Detail&Repair Finish Product Data Sheet. POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Phoenix, AZ • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1 1 1 1 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.us General line: (888)410-1375 (954)233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions?technical@polyglass.com Produd Disclaitmetr: Unless otherwise incorporated into or part of o supplemental manufacturer's warranty,Polygloss warrants its product(s)against manufacturing defects in is product that directly results in leal fora period of 5 years InEtW Rapid Ratings' Weathered Solar Reflectance 0.77 0.72 Pending Thermal Emittance 0.90 0.90 Pending C R C Solar Reflectance Index(SRI) 96 89 Pending N,TI�G I M IC,I Rated Product ID Number 0616-0011 a Licensed Seller ID Number 0616 'CRRC Rapid RciWv, an iaa:n lobwao"gW vole,Ihol wnL46k wool"v4­TI,­vAm vril be mplomd wish le memor.d ivtty+m agtd valrm upas-"A ion of fhe w_i=riR prom, Cad Roof itirg cound ro*v ane dera and br a rued ter of caldison,,and may w be approprKAe lar cid m r irg-mord­W perform The aouoldbooF,do nReew cim1wadrnino ce ROOFING AND WATERPROOFING SYSTEMS M-N+fooura d Iha ihae vvae trot in a000rderm walr le Cool Roar Rai Coureil Refer to safety data sheet)SDS)for specific data and handling o our products.All data urnished refers to standard t r production and is given in good faith within the applicable manufacturing and resting tolerances. Polygloss U.S.A.,Inc.,reserves the right lo improve and charge its products ot any time without prior notice.Polyglass U.S.A., MAAEI Inc.cannot be held responsible for the use of its products under conditions beyond its own control. a a For most current product data and warranty information,visit www.pofyglass.us Copyright 02016 by Polyglass U S A,Inc and all rights are reserved WWWPOfY9fit755.u5 Daft:ov/ie•Dad PMYFW.Uuo 0&A #ONEMOJetc. TABLE 11: DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Roof Cover(Note 1S) No. Deck(Note 1) Primer Joint Treatment Base Ply Pty Cap Ply MDP(psf) APA rated,7/16 OSB joints are covered with 4-inch wide strips of Elastoflex SA V,rolled into place to Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W-182 CAT,0.418 in., None -52.5 Exposure 1 OSB create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA W-183 Min.15/32-inch None None SBS-SA (Optional) (Optional SBS-SA,SBS- SBS-SA,APP-SA,SBS- -90.0 TA,APP-TA TA,APP-TA W-184 Min.15/32-inch (Optional)PG100 None Polyflex SA Base (Optional)APP-TA APP-TA -90.0 plywood W-185 Min.15/32-inch PG100 None SBS-SA -97.5 Options SBS-SA,SBS- SBS-SA,APP-SA,SBS- plywood TA,APP-TA TA,APP-TA Min.15/32-inch (OPlywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- 97.5 W-186 plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR TA,APP-TA TA,APP-TA Min.15/32-inch POLYBRITE 745 or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W-187 plywood WB3000 None SBS-SA 105.0 TA,APP-TA TA,APP-TA Min.15/32-inch Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W 188 plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA 135.0 Min.15/32-inch Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into W-189 (Optional)PG100 Polyflex SA Base (Optional)APP-TA APP-TA 135.0 plywood place to create continuous bond. NEMO ETC,LLC Evaluation Report P9290.02.08-1122 for FL1654-R24 eertificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 29 of 69 Installation Guide �'.40ES0 Installing LMetal Edginn- When installing metal edging,prime with either Polyglass PG 100 or other asphaltic primer that meets ASTM D41,WB 3000 primer ( or other commercially available water-based acrylic primer. f 1. The roof flange of the edge metal should be 3"-4"wide. 2. Install the roof flange of the edge metal over the base sheet strip-in at the lowest point on the roof.Nail the edge metal 4"on center in a staggered pattern. 3. Install Elastoflex•'SA V base sheet onto the edge metal Installing .` 5,heets: leaving 112"of edge metal exposed at the eaves. Prior to installation,allow the membranes to relax in the sun for a minimum of 15 minutes. lnstallinq ADESO SA Cap Sheet Polyglass SA cap sheets are available in SBS(Elastoflexx SA P) • Start installation by cutting Elastoflex•SA V base sheet to and APP(Polyflexa SA P,Polyfresko•G SA)formulas in eleven suitable lengths. colors. • Lay the membrane flat and align the membrane at the lowest edge of the roof Ambient temperatures should be 40'F and rising when • Once SA base sheet is in place,fold sheet in half to installing Polyglass SA cap sheets. remove split release film at a 90 degree angle in a constant Do not install when water in any form exists. motion All roof deck application areas must have positive • After both sides of release film are removed,position the drainage,continuous support,and be structurally sound to next Elastoflex• SA V membrane by overlapping seams of support the dead load requirements of the roofing system. the top sheet selvage edge or SEALLap®a minimum of 6" Prior to installing SA cap sheets,be sure the surface is • Press the membrane with firm and even pressure clean of dirt and debris. • Cut a 45 degree angle at the top corner of sheet,and at all Cut the SA cap sheet to manageable lengths for the build-up of joints such as T-joints and remove protective conditions and allow the cut sheets to relax prior to tape on SEALLap•and press next membrane at seam installation. • Use hand roller at laps to ensure full adhesion The cap sheet should be installed with the selvage edge • Once Elastoflex•'SA V membrane is installed,be sure to away from the eaves edge. run 80 Ib roller over the roof surface to ensure full adhesion 1 � 4-1 r;. ) 5 6 Installation Guide y Lay the membrane on the roof aligned with the eaves edge at the lowest point on the roof. Press each sheet into place with firm,even pressure. • Once SA cap sheet is in place,fold sheet in half to remove Roll edges and all lap seams firmly with a hand roller to ensure full adhesion. split release film at a 90 degree angle in a constant motion After each roll is completed,go over with ann 80 pound firmly holding the half of the sheet that is in contact with the roof in place as the liner is removed. roller with uniform pressure.Start at the center and work • After both sides of release film are removed,position the outward to remove trapped air. next SA cap sheet by overlapping seams of the top sheet For the succeeding sheet,position it by completely overlapping the selvage edge of the previous sheet. selvage edge or SEALLap''. • Do not remove the remaining release film covering the side • Only remove enough of the selvage edge release film on lap selvage edge at this time the preceding roll to complete each section of the install. • The end of each roll of SA cap has a factory end lap When SA cap sheets are installed,be sure to run 80 Ib selvage edge covered with a release film or FASTLap'. roller over roof surface to ensure full adhesion. Remove the FASTLap•'release film and press the After 3 full thermal cycles,the roof system can provide a overlapping sheet into place. watertight,membrane system. • In cooler weather,it is recommended to hot air weld or apply modified asphalt flashing cement at all end lap seams. AML �i�E [ • Cut 45 degree angle at all build-up on seams and T-joints. >ontR� �1 ! :ff y , Installation Guide DETAILS Do's of Polyglass ADESO S(Ai-Adhered TYPICAL ROOF EDGE DETAIL roof systr-ms- 1. Store rolls upright on pallets in dry ventilated indoor areas 2. Install material when ambient temperatures are 40°F degrees and rising 3. Only store and remove product from packaging on the same day of installation Caplet 4. Prime all concrete,masonry,metal or metallic surfaces 5. Prime all vertical surfaces 6. Apply to clean,dry,dust-free surfaces 7. Remove split release film at 90 degree angle 8. Roll all SEALLap®and FASTLapl-seams to ensure 100%adhesion Base Sheet-Field 9. Reinforce all inside and outside corners 10. Lap granule to granule end laps at 6" 11. Heat weld or use SBS mastic at all laps and joints where adhesive compound laps onto granule surfaces. Wood Roof Deck • Don'ts of Polyglass ADESO Self-Adhered roof systems: �j Approx.3/4" ° 1. Don't store material in direct sunlight Wood Nailer Drip Edge�--► 2. Don't install during inclement weather 3. Don't apply to dirty,wet or dusty substrate Fascia Continuous Cleat 4. Don't apply directly to shingles or similar roof coverings Base Sheet(Strip In) How to transition from a low slope t steep slope: To ensure a watertight transition between the low slope system and the sloped roof,the Elastoflexl SA V base sheet should extend at least 12" beyond the steep slope transition.The Elastoflex SA V starter strip cut to required Polyglass SA cap sheet should extend up the steep slope part 0 width,adhered to deck.Ensure the surface is of the roof a minimum of 18"beyond the transition point. clean and dust free. Flashing of walls,roof terminations and penetrations can be done with the Polyglass SA roof system. Begin installation of steep slope underlayment beginning 2" above slope transition. Prime deck when required or acceptable roof insulation attached to deck.Adhere Elastoflex Refer to available illustrative details at polyglass.us. SA V strip-in-piece to deck and over nailer 0 below edge metal. POLYFRESKOO G SA HIGHLY REFLECTIVE SELF-ADHERED APP CAP SHEET . PRODUCT DESCRIPTION Polyfresko G SA,is a highly reflective,self-adhered granular surfaced otactic polypropylene(APP)modi- fied bitumen roofing membrane manufactured using patented ADESOODual-Compound Self-Adhesive technology whereby a "true" APP compound is applied on the top layer and an aggressive self-adhesive compound on the bottom. Polyfresko G SA membrane performs to Energy Stars standards for reflectivity, is a Califor- , nia Title 24 compliant membrane, achieves Class A fire rating and has been tested to ensure long-term performance in the most extreme environments. Polyfresko G SA membrane is listed with the Cool Roof Rating Council(CRRC)with a Solar Reflectance Index(SRI)of 96. Polyfresko G SA membrane features CURE Technology - an innovative thin film technology attributing to exceptional granule retention, stain and discoloration resistance and UV .4�E.s'O ©MRE stabilization for long term durability and performance. CURE Technology is solvent-free and envi •,o " ��•�� ronmentally friendly. PRODUCT DATA Polyfresko G SA is constructed with a high performance polyester reinforcement providing a roof ft ing membrane with exceptional tensile strength and dimensional stability. Polyfresko G SA features Coverage(Approx).......... 100 s q s patented FastLopO for granule free roll ends, as well as Seallae, a factory applied adhesive Weights(Nominal) x)al) ......... ...; 1 0 lbs treatment at the membrane overlap. Each of these patented features provide for greater ease of Thickness(Nominal) .........4.0 mm; m x mils application as well as improved product performance. Roll Size .......32'10"..39 .... .l Om.. 1 m) Rolls/Pallet..... ..... ...............................20 TYPICAL APPLICATIONS • Designed for applications where using a propane torch is undesirable or prohibited • '-or application directly over acceptable substrates and/or part of a multi-ply roof system APPLICABLE STANDARDS • Ideal for new roofing, re-roofing or for flashing detail • ASTM D6222 Type I FEATURES AND BENEFITS • UL Classified for use in class A, B or • Suitable for most cool roof specifications; SRI value of 96 roofs,as listed in the latest UL"Roofing • Premium membrane construction for exceptional durability and puncture resistance Materials and Systems Directory" • Exceptional granule retention and stain resistance • Miami Dade Code Compliance • ICC ESR-2018 TECHNICAL DESCRIPTION • CRRC Listed • FBC TEST • . PROPERTY ASTM VALUE TDI ASTM D5147 Peak load @ 23+/ 8.8 (50)-2C (73.4+/-3.6F), MD } C us 1CC and XMD, min, kN/m(Ibf/in.) --- ASTM D5147 Elongation®23+/-2C (73.4+/-3.61`); MD 23 " and XMD, min(%) ASTM D5147 Tear Strength @ 23+/-2C(73.4+/-3.6F), 311 (70) min, N(Ibf) ASTM D5147 Low Temperature Flexibility, max, C(F) 0(321 PRODUCT WARRANTY ASTM D5147 Granule Embedment, g 2 Polyglass U.S.A., Inc. commercial roofing membranes can be backed with a manufacturer's ASTM D 1970 Adhesion to Plywood @ 40°F, min, Ibf/ft width 2.0 warranty for up to 20 years when used as part ASTM D 1970 Adhesion to Plywood 0 75°F, min, Ibf/ft width 12.0 of an approved,multi-ply roofing system.Please see your Polyglass U.S.A., Inc. Sales or Technical ASTM D1970 Sealability around nail pass Representative for specifications and details. ASTM D 1970 Waterproof integrity after low temp flexibility pass ASTM D 1970 Woterprnof integrity of lap seam pass hOOFING AND t1'ATE RPR001''lNG S)'STE'.t5 AVAILABLE COLORS :�• � Highly Reflective White MADE► rnny69''teQn15 17J Pol cglas.,L'5.A.,1,r;and oA r!gYs are resenred www.polyglass.us � Edition Df.:10/15•Doc#POLYFRESKO G SA r ,1 1 ` POLYFRESKOO G SA HIGHLY REFLECTIVE SELF-ADHERED APP CAP SHEET APPLICATION INSTRUCTIONS Pole esko G SA is intended to be used as a cap sheet for new or re-roof appplications as part of a multi-ply system when applied to acceptable insulations and/or coverboords for commercial and residential structures. Polytresko G SA may also be applied directly to approved wood deck substrates of non-occupied spaces such as carports, sheds, canopies, etc. • Apply only when the weather and forecast is dry and the ambient air temperature and substrate is 40aF(5aC)and rising. • Apply over clean,dry,dust and debris-free substrates. Prime concrete decks prior to application with PG 100 Asphalt Primer. • When re-roofing, remove all prior roofing materials down to a clean debrisfree substrate and properly close-off all abandoned roof penetrations. • Concrete or steel decks shall be designed with proper expansion devices. • Wood decks shall have all joints blocked and/or properly supported as required by Code. • Ensure the installation of Polyfresko G SA does not prevent the ventilation of existing construction. • Do not apply over shingles or other granulated surface. • While installing Polyfresko G SA: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Start by removing the first 18-24"of release film. 4. Press the membrane into place with firm and even pressure. Roll the edges with a silicone hand roller to ensure complete adhesion. 5. Gradually remove the remaining release film applying pressure from the center to the edges as you go. 6. Position successive rolls providing a minimum 6"end lap and 4"side lap. End laps or any lap of the adhesive backside to the reflective surface to be sealed using a hot-air welder or Homeless torch. Ensure a watertight seal. 7. All flow at seams to have granule broadcast into the molten compound. Using the Polyglass Detail&Repair Finish to cover the granules for a uniform reflective appearance. 8. After installation of the entire roof surface, roll with an 80# split-face linoleum roller. Take care on sloped roofs by securing the roller and applicator with the appropriate safety equipment. • Details and flashing may be installed using Polyfresko G SA with a hot air welder or with PG 500 Roof Cement. Check project details for proper installation requirements. • Use Polyglass Detail&Repair Finish to treat seams on Polyfresko G SA cap sheet. For more information, refer to the Polyglass Detail&Repair Finish Product Data Sheet. POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1 1 1 1 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.us Genera(Line: (888)410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions?technical@polyglass.com Product Diselahom Unless otherwise incorporated into or parr of a supplemental manufacturer's warranty,Polygloss warrants its product(s)against manufacturing defects in of dectly results in leakage for a period of 5 years. Initial Weathered OTO ''err Solar Reflectance 0.77 Pending 111101- - Thermal Emittance 0.90 Pending C Ra Solar Reflectance Index(SRI) 96 Pending nn nrcc , v n Rated Product ID Number 0616-0011 a Licensed Seller ID Number 0616 Cool Pool Rating Council ratings are determined For a fixed set of conditions,and may not be appropriate for determining seasonal energy per to mance The actual effect of solar reflectance and Thermal emitiance on building performance may wry. Manufacturer of product stipulates that these ratings were determined in accordance with the applicable Coal Roof Council procedure; a 110011 N(;:UN D WA I F R I'l2 OO1 1.\t,ti\'III M S Refer to safety data sheet 1SDSI for specific data and handling of our F r ot,ds Af mita umishAd refers tc standardmd1 Vkcl Q production and is given in good faith wilhin the applicable onufaui ing and testing tolerances. Pofygloss U.S.A.,Inc.,reserves the right to improve and change its products at any tines without prior nonce.Polyglass U.S.A., Inc.cannot be held responsible for the use of its products under conditions beyond its own control. &MAPEI For most current product data and warrant'information,visit www.polygloss,us Copyright @2015 by Polyglass t.I.S A,Inc.and all rights are reserved www.polyglass.us Edition Date:10/1S•DocM P■OLYFINSKO 0 SA EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 TRINITY ERD 353 Christian Street Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P9290.02.08-114 150 Lyon Drive FL1654-116 Fernley, NV 89408 Date of Issuance: 02/11/2008 Revision 4: 12/07/2009 SCOPE: This Evaluation Report is issued under Rule 9B-72 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2007 Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 33-page Appendix. Prepared by: Q`.•�ico 541!` /: •:r:_ The facsimile seal appearing was authorized = �_f� .'4= by Robert Nieminen,P.E.on 12/07/2009 ;?:,• t• This does not serve as an electronically signed Robert J.M. Nieminen, P.E. '.,�� �=^a C•.:'' document. Signed,sealed hardcopies have been Florida Registration No. 59166, Florida DCA ANE1983 •'';,,5�+���vti'. ` transmitted to the Product Approval Administrator and •��•• ""` to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4470/ 4450 1992 1504.7 Impact FM 4470 1992 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2000 1507.11.2 Physical Properties ASTM D6222 2002 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) FM 4470 P13760.07.09 07/23/2009 ERD (TST6049) FM 4470 P13770.09.09 09/01/2009 ERD (TST6049) FM 4470 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470 P30550.12.09 12/02/2009 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470 3018332 01/31/2006 FM Approvals (TST1867) FM 4470 3023368 03/20/2006 FM Approvals (TST1867) FM 4470 3024594 05/23/2006 FM Approvals (TST1867) FM 4470 3023458 07/18/2006 FM Approvals (TST1867) FM 4470 3030668 09/12/2007 PRI (TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008 UL (QUA1734) Quality Control UL File R14571 Exp. 11/30/2012 Miami-Dade (CER1592) Physical Properties Various NOAs Various Exterior Research and Design, LLC. Evaluation Report P929O.O2.O8-R4 Certificate of Authorization#9503 FL1654-R6 Revision 4: 12/07/2009 Page 2 of 5 TRINITY ERD 4. PRODUCT DESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. Table 1: Roll-Goods for Polyglass Modified Bitumen Roof Systems Type Product Specification Reference Grade Type Polyglass G2 Base ASTM D4601 N/A II Base Sheets Modibase ASTM D4601 N/A II Elastobase S I Elastoflex V S I Elastoflex SA V ASTM D6163 S I Elastoflex SA V Vent S I Elastoflex SA V Vent FR S I Elastoflex SA V FR S I Elastobase Poly S I Elastoflex S6 S I Elastoflex S6 G G I SBS Membranes Elastoflex 56 G FR G I Polyfresko MOP S I Polyfresko MOP FR ASTM D6164 S I Elastoshield TS G S I Elastoshield TS G FR G I Elastoflex SA P G I Elastoflex SA P FR G I Polyfresko SBS SAP S I Polyfresko SBS SAP FR S I Polyflex S I Polyflex G G I Polyflex G FR G I Polyfresko Torch S I Polyfresko Torch FR S I Polybond S I APP Membranes Polybond G ASTM D6222 G I Polyflex SA P G I Polyflex SA P FR G I Polyfresko APP SAP 5 I Polyfresko APP SAP FR S I Polykool S I Polybianko S I Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R4 Certificate of Authorization#9503 FL1654-R6 Revision 4: 12/07/2009 Page 3 of 5 TRINITY ERD 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in HVHZ. 5.2 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.4 Unless otherwise noted in Appendix 1, roof decking and its attachment shall be specified and installed to meet project design criteria to the satisfaction of the AH]. 5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.6 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. 5.7 For fully-adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.8 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105. 5.9 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907 or FM LPDS 1-52 shall be conducted on mock-ups of the proposed new roof assembly. 5.10 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AH], as documented through field uplift testing in accordance with ASTM E907 or FM LPDS 1-52. 5.11 Metal edge attachment (exept gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.12 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 9B-72. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen roof systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R4 Certificate of Authorization#9503 FL1654-116 Revision 4: 12/07/2009 Page 4 of 5 TRINITY ERD 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. PG200 Non Fibered Roof Coating or Mule-Hide 111 Non-Fibrated Roof Coating; PG300 Fibered Roof Coating or Mule-Hide 102 Fibrated Roof Coating; PG600 Non-Fibered Aluminum Roof Coating or Mule-Hide 416 Standard Non-Fibrated Aluminum Roof Coating; PG650 Fibered Aluminum Roof Coating or Mule-Hide 406 Standard Fibrated Aluminum Roof Coating; PG700 White Reflective Roof Coating; PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule-Hide 311 Emulsion Non-Fibrated; PG850 Fibered Asphalt Emulsion Roof Coating or Mule-Hide 301 Emulsion Fibrated; Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule-Hide 410 Premium Non-Fibrated Aluminum Roof Coating; > Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule-Hide 401 Premium Fibrated Aluminum Roof Coating; Polybrite 70 White Elastomeric Roof Coating. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9B-72 QA requirements 9. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743 (847) 664-3281 - THE 33-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R4 Certificate of Authorization#9503 FL1654-R6 Revision 4: 12/07/2009 Page 5 of 5 TRINITY ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof(Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4-5 IA-2 Wood New, Reroof(Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6 1B Wood New, Reroof(Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 1C Wood New, Reroof(Tear-Off) or Recover C Mech.Attached Insulation, Bonded Roof Cover 8 1D Wood New, Reroof(Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 9 1E Wood New or Reroof(Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 10-11 1F Wood New or Reroof(Tear-Off) F Non-Insulated, Bonded Roof Cover 11 2A Steel or Conc. New, Reroof(Tear-Off)or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 2B Steel or Conc. New, Reroof(Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 13 2C Steel or Conc. New, Reroof(Tear-Off)or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14 3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 15-17 3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 18-19 3B Concrete New or Reroof(Tear-Off) F Non-Insulated, Bonded Roof Cover 19 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 20-21 4B LWIC New or Reroof(Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 22 4C LWIC New or Reroof(Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 23-26 5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 27 5B CWF New, Reroof(Tear-Off) or Recover A-2 Mech.Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 28 5C CWF New, Reroof(Tear-Off)or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 29 5D CWF New, Reroof(Tear-Off) or Recover C Mech.Attached Insulation, Bonded Roof Cover 29 5E CWF New, Reroof(Tear-Off)or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 29 6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 30 6B Gypsum New, Reroof(Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 30 6C Gypsum New, Reroof(Tear-Off)or Recover C Mech. Attached Insulation, Bonded Roof Cover 31 6D Gypsum New, Reroof(Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 31 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 32 7B Various Recover F Non-Insulated, Bonded Base Sheet, Bonded Roof Cover 33 Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R4 for FL1654-R6 Certificate of Authorization #9503 Revision 4: 12/07/2009 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 33 TRINITY ERD The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AH]. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: Wood: Minimum 3/4-inch penetration. Steel: Minimum 3/4-inch penetration and engage the top flute of the steel deck. > Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. Hot asphalt at 20-40 lbs/square. Dow Insta-Stik Roofing Adhesive is continuous 3/4 to 1-inch wide beads, 12-inch o.c. Millennium One Step Foamable Adhesive in continuous '/i to 3/4-inch wide beads, 12-inch o.c. > OlyBond 500 Adhesive Fastener in continuous 3/4 to 1-inch wide ribbons, 12-inch o.c. using OMG PaceCart of SpotShot dispensing system. Note: OlyBond 500 Green may be used in any system listing OlyBond 500. > TITESET Insulation Adhesive in continuous 2'/2-3'/2-inch wide ribbons, 12-inch o.c. 4. Unless otherwise noted, the insulation may be any polyisocyanu rate, polystyrene, fiberboard, perlite and/or gypsum-based insulation board that meets the QA requirements of F.A.C. Rule 9B-72 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. 5. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 6. For mechanically attached or strip-bonded components, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. 7. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 8. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105. 9. For existing substrates in a bonded recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907 or FM LPDS 1-52. 10. Unless otherwise noted, all insulation references are flat stock. Tapered polyisocyanurate may be substituted for flat stock board with the following Maximum Design Pressure (MDP) limitations: > Insta-Stik Roofing Adhesive: MDP -120.0 psf > OlyBond 500 Adhesive Fastener: MDP -120.0 psf > TITESET Insulation Adhesive: MDP -117.5 psf Exterior Research and Design,LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R4 for FL1654-116 Certificate of Authorization #9503 Revision 4: 12/07/2009 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 33 TRINITY ERS 11. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Table 1: Polyglass Roof Covers Reference Layer Material Application BP-AA Base Polyglass G2 Base, Modibase, FBC Approved ASTM D4601, Type II (Base and Ply sheets, Hot asphalt at 20-40 Asphalt-Applied) Ply FBC Approved ASTM D2178,Type IV or VI or ASTM D4601, Type II lbs/square SBS-AA Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 Hot asphalt at 20-40 (SBS,Asphalt-Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko lbs/square MOP, Polyfresko MOP FR SBS-TA Base or Ply Elastoflex V, Elastoflex S6 (SBS,Torch-Applied) Ca Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G Torch-Applied Cap FR, Polyfresko MOP, Polyfresko MOP FR SBS-SA Base Elastoflex SA V, Elastoflex SA V FR (SBS, Self-Adhering) Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR Self-Adhering APP-TA Base or Ply Polyflex, Polybond APP,Torch-Applied) Torch-Applied ( PP ) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR APP-SA Cap Polyflex SA P, Polyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko Self-Adhering (APP, Self-Adhering) 12. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. > PG200 Non Fibered Roof Coating or Mule-Hide 111 Non-Fibrated Roof Coating; > PG300 Fibered Roof Coating or Mule-Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule-Hide 416 Standard Non-Fibrated Aluminum Roof Coating; > PG650 Fibered Aluminum Roof Coating or Mule-Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule-Hide 311 Emulsion Non-Fibrated; > PG850 Fibered Asphalt Emulsion Roof Coating or Mule-Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule-Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule-Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 13. The following represent priming requirements for gypsum-based coverboards: ➢ DensDeck and DensDeck Prime shall be field-primed with PG100 prior to self-adhering or torch-applied membrane application. No priming is required for hot-asphalt membrane applications. Securock or DensDeck GuraGuard do not require field priming for any membrane application. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R4 for FL1654-R6 Certificate of Authorization #9503 Revision 4: 12/07/2009 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 33 TRINITY ERD TABLE IA-1: WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover No. Roof Deck MDP(psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap Elastobase, Min. v." Elastobase Poly, 32 ga., 1- 8"o.c. in 4" (Optional) DensDeck, Min. 19/32" DensDeck Polyglass G2 Base, 5/8" lap and 8" FBC plywood at max. Prime, CertainTeed diameter tin o.c. in three, Approved, (Optional) SBS-AA, 24"spans Securock, BP-AA or W-1 Glasbase,Firestone caps with it equally ASTM Hot asphalt 7 " Hot asphalt BP-AA or SBS-TA, -52.5 attached 6"O.C. Min. /< SBS-AA with 8d common MB Base,JM Perma- ga,annular spaced, C1289,type FescoBoard SBS-AA APP-TA Ply 28,Tamko Glass ring shank staggered II polyiso- nails Base or GAFGLAS nails center rows cyanurate H min. #75 HD Wood Fiber Elastobase, Min. 19/32" Elastobase Poly, 32 ga., 1- 8"o.c. in 4" (Optional) Polyglass G2 Base, 5/8" lap and 8" FBC Min. 1/4" plywood at max. CertainTeed diameter tin o.c. in three, Approved, DensDeck, (Optional) SBS-SA, 24"spans One or APP-SA, W-2 Glasbase,Firestone caps with 11 equally ASTM Hot asphalt DensDeck Hot asphalt SBS-SA 52.5 attached 6"o.c. more SBS- SBS-TA or M8 Base, JM Perma- ga. annular spaced, C1269,type Prime, with Sd common Ply 28,Tamko Glass ring shank staggered II polyiso- Securock SA APP-TA nails Base or GAFGLAS nails center rows cyanurate #75 Min. '/a" Min. 19/32" Polyglass G2 Base, 32 ga., 1- 8"o.c. in 4" (Optional) DensDeck, plywood at max. CertainTeed 5/8" lap and 8" FBC DensDeck Prime, 24"spans Glasbase,Firestone diameter tin o.c. in three, Approved, (Optional) SBS AA, Securock, BP-AA or W-3 attached 4"o.c. MB Base,JM Perma- caps with 11 equally ASTM Hot asphalt Hot asphalt BP-AA or SBS-TA, 60.0 Min. 3/a" SBS-AA with Bid common Ply 28,Tamko Glass ga.annular spaced, C1289,type SBS AA APP-TA FescoBoard nails or 6"o.c. Base or GAFGLAS ring shank staggered II polyiso- with #8 screws #75 nails center rows cyanurate H h' min, HD Wood Fiber Min. 19/32" Polyglass G2 Base, 32 ga., 1- 8"ox, in 4" (Optional) plywood at max. CertainTeed 5/8" lap and 8" FBC Min. 1/4" (Optional) SBS-SA, 24"spans Glasbase, Firestone diameter tin o.c. in three, Approved, DensDeck, One or APP-SA, W-4 attached 4"o.c. MB Base,JM Perma- caps with 11 equally ASTM Hot asphalt DensDeck Hot asphalt SBS-SA -60.0 with Bid common Ply 28,Tamko Glass ga.annular spaced, C1289,type Prime, more 585 SBS-TA or nails or 6"o.c. Base or GAFGLAS ring shank staggered II polyiso- Securock SA APP-TA with #8 screws #75 nails center rows cyanurate Insta-Stick, Min. 19/32" 32 ga., 1- 6"o.c. in 4" Min. 2" OlyBond Insta-Stick, plywood at max. 5/8" lap and 6" ACFoam II, 500, Min. 'A" OlyBond 24"spans Elastobase or BP-AA or diameter tin o.c. in four, III, H-Shield, TITESET or DensDeck, 500, (Optional) SBS-AA, W-5 attached 4"o.c. caps with 12 equally H-Shield CG, WT One Step DensDeck TITESET or BP-AA or SBS-TA, -60.0 with Bid common Elastobase Poly ga. annular spaced, Multi-Max Foamable, Prime or WT One Step SBS-AA SBS-AA APP-TA nails or 6"o.c. ring shank staggered FA3 or atop Securock Foamable, with#8 screws nails center rows ENRGY-3 fastener 12"o.c. rows,7"oc Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R4 for FL1654-R6 Certificate of Authorization #9503 Revision 4: 12/07/2009 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 33 TRINITY ERS TABLE IA-1: WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover No. Roof Deck Type Fasteners Attach Type Attach Type Attach Base Ply Cap MDP(psf) Insta-Stick, Min. 19/32" 32 ga., 1- 6"o.c. in 4" Min. 2" OlyBond Insta-Stick, plywood at max. 5/8" lap and 6" ACFoam II, 500, (Optional) OlyBond 24"spans diameter tin o.c. in four, III,H-Shield, TTTESET or Additioal 500, (Optional) SBS-SA,, Elastobase or One or APP-SA W-6 attached 4"o.c. caps with 12 equally H-Shield CG, WT One Step layers of TITESET or SBS-SA -60.0 with 8d common Elastobase Poly ga.annular spaced, Multi-Max Foamable, base WT One Step more SBS- SBS-TA or nails or 6"o.c. ring shank staggered FA3 or atop insulation Foamable, SA APP-TA with#8 screws nails center rows ENRGY-3 fastener 12"o.c. rows, 7"oc Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R4 for FL1654-R6 Certificate of Authorization #9503 Revision 4: 12/07/2009 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 5 of 33