Loading...
800 Cavalla Rd ROW19-0029 Fiber Cable RIGHT OF WAY PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROW19-0029 ISSUED: 8/23/2019 800 SEMINOLE ROAD ATLANTIC BEACH. FL 32233 EXPIRES: 11/21/2019 MUST CALL • • • • la 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL •RK MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' ! a BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH • ! OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 800 CAVALLA RD RIGHT OF WAY SINGLE OR TWO FIBER CABLE - ATT $0.00 FAMILY RIGHT OF WAY TYPE OF ZONING: : ! • • • GROUP: 171717 0010 ROYAL PALMS UNIT 02A3.00 COMPANY: ADDRESS: TrueNet Communications 7666 Blanding BLVD JACKSONVILLE FL 32244 • ADDRESS: ' WILBURTH JOHN S TRUST 13825 BELLA RIVA LN JACKSONVILLE FL 32225 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF . ! . Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc., Republic Services,Donovan Dumpsters, Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way. Issued Date: 8/23/2019 1 of 2 RIGHT OF WAY PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROW19-0029 J r> 800 SEMINOLE ROAD ISSUED: 8/23/2019 ATLANTIC BEACH. FL 32233 EXPIRES: 11/21/2019 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 4 PUBLIC WORKS UTILITY ROAD CUT INFORMATIONAL Notes: Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the plans. 5 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 6 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 7 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. 8 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. 9 PUBLIC UTILITIES ADDITIONAL COMMENTS PUBLIC UTILITIES INFORMATIONAL Notes: A FIELD VERIFICATION EVERY 20"MUST BE DONE BEFORE ANY DIRECTIONAL DRILLING WILL BE ALLOWED DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date:8/23/2019 2 of 2 �SL:Lyj,� City of Atlantic Beach + APPLICATION NUMBER Building Department ( o be assigned by the Building Department.) 800 Seminole Road q O f ©,,� l ( _ �Q j Atlantic Beach, Florida 32233-5445 AUGV L Z��� Yv ) Phone(904)247-5826 - Fax(904)247-58) E-mail: building-dept@coab.us �Y. Date routed: �� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: `C"o ( ,AVRt Ut - PD_ Department review required Yes No Building Applicant: ( 7" Ti�I�GNE(` �plYt,11 Planning &Zoning Tree Administrator Project: d, �� �(��j�--� ublicWorks u lic Utilities ublic Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: VApproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING r1 PLANNING &ZONING Reviewed by� / Date: TREE ADMIN. Second Review: A roved as revised. Denied. ❑ pp ❑ ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assi ned by the Building Department.) !� 800 Seminole Road ' ©`Yv„ l ( _ �Q Atlantic Beach, Florida 32233-5445 / Phone(904)247-5826 - Fax(904)247-5845.I; ; tr E-mail: building-dept@coab.us Date routed: City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: ©0 CAVAN Department review required Yes No _ Building Applicant: f�1 ( 7— + _ e } Nl 00/n'n Planning &Zoning Tree Administrator Project: �(.�f✓� ��'��-'� tfrublic Works u lic Utilities ublic Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATr6N STATUS Reviewing Department First Review: pproved. []Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Zate: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: 2 2-111 Application#: 14 Project Address: Sob Ci-i U U4 Check Box Check APPLICATION TRACKING COMMENTS to Add Box to Comment Print Underground Avoid damage to underground water and sewer utilities. Verify vertical and Water Sewer horizontal location of utilities. Hand dig if necessary. If field coordination is Utilities needed, call 247-5878. Meter Boxes Ensure all meter boxes, sewer cleanouts and valve covers are set to grade Sewer Cleanout and visible. ❑ ❑ A sewer cleanout must be installed at the property line. Cleanout must be RT1 Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade ❑ ❑ Cleanout and visible. A reduced pressure zone backflow preventer must be installed if irrigation will RPZ be provided or if there is a private well on the property. Backflow preventer ❑ ❑ Backflow must be tested by a certified tester and a copy of the results sent to Public Utilities. Plans note the building will be unsprinkled. If plans change,any fire line Sensus installed must be metered with a Sensus touch-read meter in a properly sized Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer ❑ ❑ Meter must be tested by a certified tester and a copy of the results sent to Public Utilities. Fire Sprinkler If fire sprinkler system is provided,call 247-5878 for backflow requirements. Backflow Requirement At a minimum,will require a double check backflow preventer. 13 13 Fire Line Fire lines must be metered with a Sensus touch-read meter. Meters larger ❑ ❑ Meter than 2" must be installed in a vault as noted in 1EA specifications. Utility Map See attached Utility Map. Z M/ Disconnect DCap Disconnect and cap water and sewer lines. E3 Inspection Must call the Inspection Line at 247-5814 to request an inspection of the Prior disconnected and capped water and sewer lines prior to demolition. 1:3 ❑ Q �- /(J 0 0 ! ' �`"�^ � 1.�►:.?�, { 310 ., s.. MH 573 CAVALLA RD .• MH-A-568 M 1 1 ` , AKA • AV \ r ' 08 804802 IN , I 812 806 80f 762760758756754752 750 t r , . 06"WWATERMAIN ` 8" SEWER MAIN FIELD VERIFICATION FOR WATER MAIN LOCATION EVERY 20' MUST BE DONE BEFORE ANY DIRECTIONAL na DRILLING IS PERFORMED. jwc; 3 � �, � � �, �► "I Ilk I� � 6" WATER MAIN �f " 6"AC WATER MAIN 16 416 FIELD VERIFICATION FOR WATER MAIN LOCATION 8, EVERY 20' MUST BE DONE BEFORE ANY DIRECTIONAL DRILLING IS PERFORMED. MH-f i S' � 835 o y 801, 7� IL 93E68205N I.r RIGHT-OF-WAY/ EASEMENT PERMIT si ~~ Permit#Issued by the City of Atlantic Beach 1 \DUy "C)C) PERNUTTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 800 CAVALLA RD Phone 904-777-9052 ext 258 Permittee ATT Tony Pellegrini Email rbontsna,truenetcommunications.com Requesting Permission to Construct Propose placing 752'of fiber cable via directional bore and handholes Location(Reference to Cross-Street) Cavalla Rd and Royal Palms Dr. • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of (Project Superintendent) with Company Name Phone • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again immediately upon completion. ,p G Date Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL /� p The foregoing instrument was acknowledged this 19-111 day of A Lt C4 U 5 __120 by ( D n+z 7r_ 1 e q Y 'y)1 who personally appeared before me and (printed nameof Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. 1L."^-I'D • pa"t_5 ct, Personally Known "-4 Signature of Notary Public,State of Florida Produced Identification(Type) e"%- BRENDA A.PAUSCHE MY COMMISSION N FF937851 �a 4 d EXPU�;Novwka 19,2019 PERMIT NOTES:. VICINITY MAP ATtT PROPOSES TO PLACE THE FOLLOWING TELEPHONE FACILITIES: PLACE 752'OF TOTAL BURIED FIBER GABLE P 30' MINIMUM DEPTH AND PLACE 4 HANDHOLE5 t MAKING 7 BORES TO PLACE FIBER FOR CAVALLA RD COMMERCIAL BLDG'5 ALONG ROYAL PALMS DR IN THE CITY OF ATLANTIC BCH. WORK ZONE MAINTENANCE OF TRAFFIC s s WORKERS WILL UTILIZE M.O.T. 602 STRIP MALL 296 1 t 660 FOR THE PROPOSED WORK 1021 SHOWN THROUGHOUT THESE DRAWINGS. sss 0" s% SEE DRAWING 7 4.0 100 ss sA q� s� PANERA WORK ZONE s A `SAT&T MANHOLE FOR THE M.OT.REFERRENCES BREAD CONTACT INFORMATION FOR THE ATtT MANAGER 899 835 815 Fl—I AT&T MANHOLE 31 763 JEFF SMITH (904) 348-3485 A INF RMATI FAT&TINSTALLER AK LLC ADAM GILLESPIE (904) 614-0016 O ATLANTIC BLVD NOTE TO PERMITTING AGENCY, PENMAN RD THE BELOW INFORMATION IS THE ORIGINAL DRAFT PERSON WWO HAS DETAILED FIELD KNOWLEDGE OF TWE PROPOSED SEE BORE DETAILS WORK TO BE PERFORMED ON THIS PERMIT REOUE5T AND prepared SHOULD DE THE FIRST POINT of CONTACT WITH dI�STIONS Permit submittal plans Here re are ty REGUARDING THESE FIELD CONDITIONS AND/OR CORRECTIONS Y g TO THIS PERMIT REQUEST. ON DWG 6 under the responsibilitycharge D I i PLACE 4 HANOHOLES 30' X 48' Company full-time employee Jonathan urer and are exempt from the signing AT�- BUR/ED SYMBOL LEGEND Ind sealing requirements prescribed -- aaw In Section 471 of the Florida Statutes. f Eris Prgmw Existing Olrsrl/prion 'ul�u oa n"rt IOPai � tif�Q o —B— —B BURIED CABLE slm�.�w�Ko ni SErx�n / ���• aw"uEo Ussla rxvKo a+"E —BJ— —BJ— BUR JOINT-TRENCH Ewanao rn"w(Iwl Jonathan Maurer ENCLOSURE III=111=III III=111=1_111 To "" 11 I- �a zQ ENCLOSURE Sr MANHOLE ATTSE aR"Wnel ptl. E EE o,ri"�""xti=I WD ------------ H--H PIPE/CONDUIT PROPOSED TELEPHONE FACILITIES / o,.• Wr PW[Pal swu E: ON RIGHT OF WAY OF /I YLLIo[S"4 E aau rz X'l 1 w1 1 We ,, co"PoPa ES EM CITY OF ATLANTIC BCH a"smsE, o oaa"all coun"lul CA-MKR� CA-MKR CABLE MARKER :d." r+ rmea r a rtz n . aF •'a •"ti'/ "I nnoll a wel 1. —EW J/ BURIED SVC WIRE ROYAL PALMS OR °K"So ME '—eP—" -'—N--' JOINT-TRENCH SVC a"NEa ax""ul Pu E•cnange: YMe"I f'aPM eo FALL Naaaurs sH.owrt".Io omlMo"m 30X48X30 HH - N/A BORE JACKSONVILLE BCH AS Eauxo amnrtm"c Ela citome ------- Designer: cSoPu. ® Pellegrini.Tony N/A CUT PAVEMENT Phone: i N/A SPLICINGPIT 904-727-1546 TELEPHONE SYSTEM HAND HOLE DETAIL 2001@(M N/A TRENCH LENWDEPTH Autnorizotiu9 �7 ') 3E68205N NOT TO SCALE O.p. I of 8 II ------------------------------R/W- I CAVALLA RD ---R/W--------------- ----------------------------- 9 1 m m - -------------------------------R/W z n m n WATER IVA VE D OEXISTING CABLE I D p II E%ISTING CABLE 808 BOG 804 802 800 Ln 17 EXISTING CABLE P 300�y✓il pp £ 764 762 760 ©EXISTING CABLE I I ©9 EXISTING CABLE I Sake Or I AT&T • I �i e 30 EXISTING CABLE i EASEMENT 1 1 1 1 -- I+yg ASPHALT 36'STORM PIPE 17 I I I 11 ASPHALT COM D/W & 40' DEPTH I I 1*k4. COM O/W m I I I 7 I I II I I 1+42' I E � I� SANITARY SEWER MANHOLE P 298 Q Ile 1 SEE BORE DETAILS ' t 60 PROPOSED AT&T ON OWG e6 m q0' HANDHOLE 30"X 48" BUTT TO SIDEWALK //YIA4�'W'l A4w,�,yl B 40' OF BURIED FIBER CABLE @ 30" MINIMUM Jonathan Maurer 9 ,® 9 sm � am m � PROPOSED AT&T �0+q$ '4' r, O 58' ROAD BORE / 4 FLEXPIPE @ 48" MINIMUM DEPTH HANDHOLE 30"X 48' 0+00\ \`\ s B .I` START Of PLACEMENT 10 90' DIRECTIONAL BORE / 4 FLEXPIPE @ 36" MINIMUM DEPTH a \ 8' BUT MAINTAIN 24" DEPTH BELOW BASE OF S ORM DRAIN 0+2A B�8 A T r S E B 80' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MI IMUM DEPTH SEWER VAVLE AT&T MANHOLE� g PROPOSED TELEPHONE FACILITIES s ON RIGHT OF WAY OF ® 712' OF BURIED FIBER CABLE @ 30" MINIMUM POM O W 0+�0 CITY OF ATLANTIC BCH e 30 ROYAL PALMS DR I 0+80' o I I 1 D Exchange: 1 ASPHALT r JACKSONVILLE BCH 6' COM D/W v 1 y Designer: ° Phone: Pellegrini,Tony 9 1 n I r 904-727-546 296 I 1 li o 295 Autnorizotion: ROYAL PALMS I 'I ABC LIOUDRS 93E68205N See Org •4 D.q. 2 or 8 p O7 EXISTING CABLE '1 I 1 — — II EXISTING CABLE ' 60' ' 1 1 17 EXISTING CABLE ' 1 1 ' 1 EXISTING CABLE I, 1 1 1 ' le EXISTING CABLE 1 I 1 11 1 13 EXISTING CABLE 1 I6 EXISTING CABLE 1 co) '1 1 � 1 17 EXISTING CABLE r It IB EXISTING CABLE ' 10' I 1 r 11 19 EXISTING CABLE 1 3 1 ®EXISTING CABLE p 1 1 � 1 1 1 1 1 +------------------------------------------ 11 m 1 11 AT&T EASEMENT 1 1 I 1 I 1 1 I 1 1 1 1 1 1 1 I 1 1 1 1 1 1 I 15 B 1 1 I 1 1 I 1� B I6 B 1 CAB e 1 JEA CAC 1 I I e 1 PWR 19 P=300 13 1 17 ,1 111 I 1 I I I I e 12 m e /i 1 IB 9 �i 11 TGBLPRSED 23• 3' 7• CAB CAB 48CAB 1Jonathan Maurer �e0r9 1 11 /"1 1 1 J L I 1 1 1 1 PROPOSED TELEPHONE FACILITIES ----------- ---------------------------------------11 1 ON RIGHT OF WAY OF 1 1 CITY OF ATLANTIC BCH 1 1 1 90C1 ROYAL PALMS OR 1 1 CD 1 4, ASPHALT E.cnonge: COM 0/W •1 1 JACKSONVILLE BCH D 1 Designer: soc 1 Pellegrinijony Fnone: 90' DIRECTIONAL BORE / 4 FLEXPIPE @ 36" MINIMUM DEPTH = i t 904-727-1546 BUT MAINTAIN 24" DEPTH BELOW BASE OF STORM DRAIN emrwrizarton: 1 0 '1 93E68205N D+g. 3 0f 8 296 ®EXISTING CABLE ROYAL PALMS A Sew Dwg •2 PLANTER EXISTING CABLE \ 1 � 9 � 60' � \ 295 ABC L I ODOR S q ASPHALT COM O/W 9 2a,y CATV GRASSED 31 B P 296 2" y ASPHALP ' 0 COM D/W �°ti e0 STbRM DRAIN 0p WATE G tiJ VAVLE P 288 STRIP MALL 9- 1021 PROPOSED AT&T HANDHOLE 0"X 48" ^� q � GRASSED y 1 3+60'.� Jonathan Maurer ASPHALT COM D/W 115' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH 4*'28' A T TSE o PROPOSED TELEPHONE FACILITIES ® 97' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH 6�A �z 9 ON RIGHT OF WAY OF 3'WI OE AAa6j1 z�` v CITY OF ATLANTIC BCH DRAIN SLOUGH \ 2� ROYAL PALMS OR STORM DRAIN ® 712' OF BURIED FIBER CABLE @ 30" MINIMUM \ z Cl SEE BORE DETAILS \ JACKSONVILLE BCH 6 GRASSED Designer: ON OWG a 9 � \ F Pellegrini,Tony BORE 3' \ Phone: SLOUGH 5•� Owg •5 904-727-1546 AUfhor1io110N 93E68205N D.Q. 4 of 8 1021 OPEN PARKING LOT ® 113' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH CAUTION ! ® 62' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH BURIED POWER y° .e �m 'x ® 712OF BURIED FIBER CABLE @ 30' MINIMUM 9 ,110 D . STORM DRAIN SEE BORE DETAILS ® EXISTING CABLE ON DWG °6 ®EXISTING CABLE 5'+8 3t EXISTING CABLE TDENT100 THE ASPHALT NST ISD/W s ®EXISTING CABLE 6'*�9 6,+3 ®EXISTING CABLE OPEN PARKING LOT �3e \ 6' 6+50 — -8 B 33 F0 FIRE * P 90 HYDRANT ° z I 6+ IE CONC 3 1 I 31 COM D/W 1 1 � I I i t 7+1 763 AT&T MANHOLE 7+12' 2" J D E n 815 r- PIZZA HUT LJI D r 3 Jonathan Maurer ASPHALP CONC "S COM O/W COM 0/W (� I I i G _ om ' ----- --------------- oo �' A T TSE - --------------- ----- P 81 3 S/W PROPOSED TELEPHONE FACILITIES SOC ON RIGHT OF WAY OF — — — — — — - - — — — — — - — — — — — — — — — — — -- — — — -- — — — — — — — — - — — — — CITY OF ATLANTIC BCH ATLANTIC BLVD AIA ROYAL PALMS OR ---------'-----------_—_--------------- -------------.-------------' -----------------.---------------------- ExcnmOe: BOL BOC JACKSONVILLE BCH 1 1 , Oesipner: Pellegrinl,Tony ----R/W-------- ------------------------------------R/W-, ---------------------------------------- Phone: om 904-727-1546 I 3 I A,thoril Otlon: D 93E68205N Z NOTE:OTHER CABLES OMITTED FOR CLARITY 7 5 of 8 O9 58' ROAD BORE / 4 FLEXPIPE @ 48" MINIMUM DEPTH ® 97' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH BORE DETAIL: Royal Palms Or MAX.REAMER SIZE: 6' BORE DETAIL: Royal Palms Or MAX.REAMER SIZE: 4' — N/A'—' SETBACK DISTANCE, SETBACK DISTANCE. 4•X4'X5' SETBACK DISTANCE, SETBACK DISTANCE, 4'X4•X5' 14• N' BORE Imo—I'' I4' BORE ROADWAY RECEIVING I COM RECEIVING PIT ENTRY ANGLE, EXIT ANGLE, ENTRY Ali 4� EXIT ANNE; CROSS SECTION 16' 16' I6' 16• If19XING NORTN 60 SB'TOTAL 91'iOiAL J0 .NT 10 90' DIRECTIONAL BORE / 4 FLEXPIPE @ 36" MINIMUM DEPTH STORM STORM r MAINTAIN 24" DEPTH BELOW BASE OF STORM DRAINEXIS® 113' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH IPE PIP 5 CABS SNG BORE DETAIL: Rowel Palms Or MAX.REAMER SIZE: 6' BORE DETAIL: Royal Palms Or MAX.REAMER SIZE: 4' s0 00 oo = ROADWAY SETBACK DISIANCEI SETBACK DISTANCE. 4'X4'X5' SETBACK DISTANCE, SETBACK DISTANCE, 1'x4'X5' v4' O 14' I4' 14' 14' SEE OWG E. 0 BORE �— BORE I BORE RECEIVING EASYRfYEM COM 0/W RECEIVING a COM 0/W a RECEIVING WA ER EXISTING CABLE SANITARY PI PE CATV PIPE ENTRY ANGLE, EXIT ANGLE. ENTRY ANGLE: ErIT ANGLE: 16' a'X 16' 16' 16 9B'TOTAL 113'TOTAL ® CROSS SECTION 80' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH ® 62' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH 100.,SOITTH ISO, DETAIL: Ronal Palms Or MAX.REAMER SIZE: 4' BORE OETAIL: Royal Palms Or MAX.REAMER SIZE: 4' SETBACK DISTANCE, SETBACK DISTANCE, SETBACK DISTANCE, SETBACK DISTANCE, ��'4 STORM STORM I4• 14, 4'XI•X5' 14• I4• 4'X4'X5' $ IPE PIP 8 EXISTING D-BORE I'— BORE 0-BORE BORE CABLE COM 0/W RECEIVING COM 0/W r— RECEIVING a a PI T a a PIT00 D OLi � � � ROADWAY 00 � ENTRY ANGLE, EXIT ANGLE: ENTRY ANGLE, Exlf ANGLE. 'AArEs O SEE vea ED9 16' 16• 16' 16' 1 YEdSUAEYEA` \\ N'TOTAL 62'TOTAL WATER EXI STING CABLE SANITARY PI PE CATV PIPE 115' DIRECTIONAL BORE / 2 FLEXPIPE @ 36" MINIMUM DEPTH BORE DETAIL: Ronal Palms Or MAX.REAMER SIZE: 4' SETBACK DISTANCE, SETBACK DISTANCE, 4'X4'X5' A T T S E I4 ---y O-BORE r-14 RECEIVING &I COM D/W t PIT BORE D E T A I S PROPOSED TELEPHONE FACILITIES ON RIGHT OF WAY OF CITY OF ATLANTIC BCH ?ANN-XE, EXIT ANGLE.16l6' ROYAL PALMS DR IIs•TOTAL Exchange: JACKSONVILLE BCH Designer: Pellegrini.Tony Ph— Jonathan Maurer Authoriza1904-727-1546 93E68205N Owg. 6 or 8 N/A- ROAD WORK END AHEAD ROAD WDRK A • • •Work Ara• • • B Teper LengN=15L sae table a A END RDaD WORK Table II ROAD Taper WORK De ce Spaang Taper De pe spaang-rangem son Length-Shoulder AHEAD • see Table) See TaDlel I VEE01sG FI1E5 - Sp°°d Nobs ORRFO � Impnl 8' to 12 .r(•(1071F•S rnf YM1 Shkr. Slgdr. Shkr. 25 28 35 12 Table 1 30 10 50 W L,Ws• Device Spacing 35 55 fie B2 60 Max.Distance Be—D°wc°s(h.) W 72 Be 107 Speed Conus or TYPeI w Type 11 15 120 150 Tea DISTANCE BETWEEN SIGNS (mom TuewarM°"`e,a BdP...x Dm 50 133 167 200 Speea Spatlng ln.l Taper Tangen) Taper Tangent 55 117 183 220 A I B 25 25 50 25 50 60 160 200 210 LIWS 10 mph wless 200 260 3010 x5 25 50 30 50 85 173 217 280 15 mph 350 350 50 mph or greater 500 500 50 tp 70 25 50 50 100 70 181 237 280 Midway Delween srgns. 8'Mnlmum°Mulder Wah )5L-Length of shoulder)aper b feet SYMBOLS GENERALNOTES DURATION NOTES W=Widlh,f WM1shp Idermfeet(mmbinedpaved end!unpaved width) ® www Area 1. when tour or more wont­d,,emer me tnrougn canto lanes in a one hour penod or less 1 Srgna ana tliannef¢irg aexipes may M omidea it an of Inc fdloynng (ezGud,ng_L xhing and terminaling the work area),tM advanced FLAGGER In shall De suoslnuled —did.—are mel: S• P.e °peed Irmn(mph) • CMnnel¢mg O-ce,(See Indus 102600) Ipr the WORKERS sign.Fpr I--pl naggers aM FI-AGGER srgns,see IMex 102603. Work operetrona are 60 mrnubs pr less. Vehrclea in the wpM area have hrgMintensrlY,roblrng.flashing, 2. SHOULDER WORK sign may be used as an alternele Ip Me WORKER sympol srgn only on the srde oecillaling,o,strobe Irghts operating. Www zone Sig, where the shoulder worw is beiig 1,11—d. A T T S E U Lane Idenp� .Do-e m W Tramc 3. Wren a side road xmersec(s the highway wrlhrn me TTC xone,addia 1 TTC dentes MLI M placed in accordance with other appii ble TCZ Indeses. PROPOSED TELEPHONE FACILITIES a For general TCz requhem°nt,and addmonal mlomv0pn,reb,1p Index 102-600. CONDITIONS ON RIGHT OF WAY OF CITY OF ATLANTIC DCH WHERE ANY VEHICLE,EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER ROYAL PALMS DR THAN 15'BUT NOT CLOSER THAN 2'TO THE EDGE OF TRAVEL WAY. Exchange: JACKSONVILLE BCH Designer: (,AST 20 DESCRIPTION: PellegrinieTony REVISION FY 2018-19 1NOEX SHEET p,":FDO TWO-LANE, TWO-WAY, WORK ON SHOULDER 102 11/01/17 R -602 1 of 1 �- STANDARD PLANS 904-727-1546 author)2at)onk 93E68205N o.0• 7 of 8 \`fir/• SYMBOLS GENERAL NOTES: jrla� ® Work Area 1.m hon encroaching work reRuiras a sidewalk closure for 60 6.Provide a cross slope with a mavimum value o10 02 for all temporary walkways. inures or greater,provitle an alternate petlestrun route. Lhannelizirlg Dewca 7.Maintain temporary walkway surlac<s and ramps Nal are 11bW firm.slip-resislanl. fl, syph Zana Sign 2.Fa spaunq of vehicular Cha ll,mg Devices.sae apple ble and hee of any.1— or—.1ds such of tales.dells,mud.construction lY vehicular temporary IraHc control Indexes. eQuipmenl,and stored material. CR Regueetl LI-t—s For EI-Temporary ).Cover or deacllvate g Or Permanent U.Ramps. pedestrian Inflic signal dl.play(s)conlrpllN B Remove lamporary walkways Immed)ately eller reopening of the sidewalk,unless cloaetl crosswalks otherwise opted m Ne plans b Lane Idenuficatwn•Deecdion of TraRc Pedestnan L.71-111 Ch.... mg Device(LCD)wdh 4 Far post mounted signs be d near or adjacent Id a sidewalk, 9.Meet Ne ngueements of IMe.522-002 for temporary cath ramps. M...-Work Zana Sign or separate Work Zona Sign maintain a minimum 7'aearance from Ne botlom of Ne sign Panel 1.Me surtace.1 Na sidewalk. 10.Place pedestrian Ipngitudlnal channelizing dew (s)suds.the IN II width If Ne N PedesNan Lpngiludinal Channeliz g Device(LCD) dosed ald...Ik.For lamporary walkways,similar la Ne Sidewalk Diversion, ® Temporary Side Wk 5.Prp d.a 5'wide temporary walkway,..—pt wTere space rezldcUans place LCDs N dakneale Eoth sides It Ne temporary walkway. m widtn p14'.Provide a 5 a 5'passvtg space for temporary walkways les.Nan 5'kl wkN et intervals npl to 11.For sidewalk diversions,ensure Nat Nere is suRiuent RAN Idr placemen)Pl sceetl 200'. ampprary sidewalk and ped,. an)mgitudinal channeli4ing device. 814 e [ CR 3R�1$SO110 V 4 CR 4 z Dison)rnM3als 8 4K I ano�D ` pp 03SO10 DEOUR R : Y AtlMM YM \- U 4 NlVM301S NtlIMLS303d a m d JO 7� p ROAD I 03SO10 mIm oo � a . Mwrcvw'a SIDEWALK Jonathan Maurer CLOSED peO6srauR x 8 DETOUR viaV SIOEWAII(CIOSED a� arr0 A 1Y1013L1 �V ATTSE useo~ 1F PROPOSED TELEPHONE FACILITIES Rc o 4 DR ROAD 4 ROAD ON RIGHT OF WAY OF WORk WORK CITY OF ATLANTIC BCH g l 4 wD A lit _�V _�/ µpm � � ROYAL PALMS DR CROSSWALK CLOSURE AND ExchongeSIDEWALK DETOUR SIDEWALK DIVERSION JACKSONVILLE BCH _ PEDESTRIAN DETOUR Designer: LAST vZOi DESCRIPTION: Pelle rini.Ton R � j EVISION FY 2018-19 INDEX SHEET Q y 11101117 W F � STANDARD PLANS PEDESTRIAN CONTROL FOR CLOSURE OF SIDEWALKS 102-660 ]of 1 904-727-1546 Autlwrliation: 93E68205N Dwq. 8 of 8