Loading...
100 Seminole Rd ROW19-0028 Comcast RIGHT OF WAY PERMIT PERMIT NUMBER ' ROW19-0028 CITY OF ATLANTIC BEACH �r ISSUED: 8/23/2019 800 SEMINOLE ROAD ATLANTIC BEACH. FL 32233 EXPIRES: 11/21/2019 i MUST CALL INSPECTION r • • 1 . + BY 4 PM FORDAY INSPE • ALL WORK MUST CONFORMTO THE CURRENT 6TH EDITION1 OF • ' ! BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: • OF • • 100 SEMINOLE RD RIGHT OF WAY SINGLE OR TWO COMCAST- 50' UG CAN $0.00 FAMILY RIGHT OF WAY FACILITY TYPE OF ! ZONING: : ! • i • GROUP: 170603 0000 SALTAIR SEC 01 COMPANY: ADDRESS: SOUTHEAST UTILITIES OF 1020 FRANKE INDUSTRIAL DRIVE AUGUSTA GA 30909 GEORGIA, INC. • ADDRESS: SOWARDS KERRY E ETAL 100 SEMINOLE RD ATLANTIC BEACH FL 3223') WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF • • Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way. Issued Date:8/23/2019 1 of 2 RIGHT OF WAY PERMIT PERMIT NUMBER s CITY OF ATLANTIC BEACH ROW19-0028 800 SEMINOLE ROAD ISSUED: 8/23/2019 \Fiji 9r ATLANTIC BEACH. FL 32233 EXPIRES: 11/21/2019 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 4 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 5 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL Notes: A full Utilities TOPO survey must be submitted to the Building Department within 30 days of completion of project. 6 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. 7 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL• Issued Date:8/23/2019 2 of 2 rSy�,v�lr, City of Atlantic Beach APPLICATION NUMBER j� Building Department (To be assigned by the Building Department.) i✓ , ,P 800 Seminole Road _O j Atlantic Beach, Florida 32233-5445 j 19 Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: `Q IPDepartment review required Yes No Building Applicant: '—"I t tanning &Zoning Tree minis ra or Project: y �� �t� V (X Lt Ct &: ubl-Work ublic Utilities C Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. []Denied. Not applicable (Circle one.) Comments: BUILDING q PLANNING &ZONING Reviewed by: � Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach �1, APPLICATION NUMBER S Building Department ?• (To be assigned by the Building Department.) i 800 Seminole Road xRow 19 _O 7 Phonte ic(04)247-5826-Fax(904)2R8ALSBeach, Forida 2233-5445 19 1019 ' t (J �0A s� E-mail: building-dept@coab.us �Y Date routed: 1 City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM t � Property Address: ` 1 � Department review required Yes No Buildin Applicant: '�"Itt fanning &Zoning Tree Administrator Project: l.J C� r> V F 0( Uk (`( S ubl c Wor � ublic Utilities c Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: VApproved. []Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING ` Reviewed b4 adz Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 rS,:Li;y� City of Atlantic Beach APPLICATION NUMBER is }� Building Department (To be assigned by the Building Department.) 800 Seminole Road Row 19 7 Atlantic Beach, Florida 32233-5445 (� Phone(904)247-5826 • Fax(904)247-5845 xi rM )r E-mail: building-dept@coab.us Date routed: City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM t � Property Address: `� 1�J�( t Department review required Yes No Building Applicant: t` S I anning &Zoning Tree Administrator Project: 7kV t— G( Cil C( e < ublic Works ublic Utilities CD Public Safety Fire Services Review fee $ 25- 2 Dept Signature � Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ON STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING 409 Reviewed by: �i. _ Date-.—K-_9049 TREE ate: --904— TREE ADMIN. Second Review: ❑Approved as revi d. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: m bef Application#: Ab w 1 -o 0 28' Project Address: 100 O Check Box Check APPLICATION TRACKING COMMENTS to Add Box to Comment Print Underground Avoid damage to underground water and sewer utilities. Verify vertical and Water Sewer horizontal location of utilities. Hand dig if necessary. If field coordination is Utilities needed, call 247-5878. Meter Boxes Ensure all meter boxes, sewer cleanouts and valve covers are set to grade Sewer Cleanout and visible. ❑ ❑ A sewer cleanout must be installed at the property line. Cleanout must be RTI Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade ❑ ❑ Cleanout and visible. A reduced pressure zone backflow preventer must be installed if irrigation will RPZ be provided or if there is a private well on the property. Backflow preventer ❑ ❑ Backflow must be tested by a certified tester and a copy of the results sent to Public Utilities. Plans note the building will be unsprinkled. If plans change,any fire line Sensus installed must be metered with a Sensus touch-read meter in a properly sized Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer ❑ ❑ Meter must be tested by a certified tester and a copy of the results sent to Public Utilities. Fire Sprinkler If fire sprinkler system is provided,call 247-5878 for backflow requirements. Backflow Requirement At a minimum,will require a double check backflow preventer. 13 1:1 Fire Line Fire lines must be metered with a Sensus touch-read meter. Meters larger 13 13Meter than 2" must be installed in a vault as noted in 1EA specifications. Utility Map See attached Utility Map. Disconnect DCap Disconnect and cap water and sewer lines. ❑ ❑ Inspection Must call the Inspection Line at 247-5814 to request an inspection of the Prior disconnected and capped water and sewer lines prior to demolition. ❑ ❑ ❑ ❑ ❑ ❑ 0 0 r O ! a Ar 44 fe' Mfa �► "a^� ++ 1 s� r a .4. C 1' { C��d is ,, J RIGHT-OF-WAY /EASEMENT PERMIT l _�L ' Permit#Issued by the City of Atlantic Beach _ C� V\1 'ERM1TT7r ??FSP«`c'RI € FOR NOTiF) 1,%(, 811 AND 0BlAi\i:sG [..TILITY LOCATES Job Address 100 SEMINOLE RD, ATLANTIC BEACH, FL Phone 405-314-9079 Permittee AFG ON BEHALF OF COMCAST Email eacksonville surveys(c-Mbercorearoup.com Requesting Permission to Construct PROPQ Location (Reference to Cross-Street) SEMIONLE RD &STURDIYANT AVE • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities. both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or casement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of EMILY CROSBY (Project Superintendent) with Company Name SOUTH AE_ST UTILITIES OF GEORGIA Phone 904-327-3663 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in imper-ous arca on iot oi-in the Cir-: d with this !Ipplication. • The permittee shall commence actual construction in good faith within 60 days . If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out arc granted only to the extent of the City's right,title and interest in the land to be entered upon and used b}-the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and m all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • 're or of Public Works shall be notified twenty-four(24)hours prior to starting work and again m diately upon c mpl 10 . �^ Date S.Ac; 9 Perm' (s m p e of'No public) «nS ct S � u 11 rr^ STATE IDA.COUNTY _h l) ! =� The fore i instrument was acknowledged this < day ofOut ty'1A <- - r by�c^t A()I �r f i�� 1 ' �� who personal` appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. l Personally Known �r Signature o Notary lie,State of Florida Produced Identification(Type) i� 'r, V"HELLE MATLnsas ._:9', ?ut;:c-state COMCAST PERMIT REQUEST FOR 100 SEMINOLE RD,ATLANTIC BEACH, FL EYxeN NOLYES fAW1Y SPMA COUNTY JACKSON —T COVNiv COUNTY —'L NASSAU COUNfY -LT- WASNMGT GApSOEN (YIWTY THESE PLANS WERE PREPARED UNDER THE °°°"Y Tr muwy �`" NAY`TGN YADLSON OGUNTr RESPONSIBLE CHARGE OF COMCAST AND �c°uNWN —k- -TY ARE EXEMPT FROM THE SIGNING AND SEALING °"Y SNANNEE SANER —TY LIBERTY VJAUA CWNTr OpIJNTr oouJrr COUNTY TAna+ REQUIREMENTS PRESCRIBED IN °UU1 COUNTY IAFAYETT —Y SECTION 471 OF THE FLORIDA STATUTES TY -ANKW Nr SYN Y muNT AucNuu me COUNTY PUT— wuun, couNTr I_M c0.TY £ 7 muNTY h � tlARIW g WUMV J VOLUSN CWNlY CY UKE CITRUS COUNTY Q L0U TM SUYTE CCUNTYE HERNANOO COUNTv ORANGE 4r COUNTY PJimmys Jewelry PCAASSCO And Pawn Shap gyM�elArt e`-Gov PANTY COUNTY eREVARG �n9r-«„ s rRo s-I�.� �GNTr INwelers CevN;ne Jec omharrJe© I� X4910 Ave SiurdivaM Ave ?ro Dudes Se3faod T P cou TY Y 5"8 Cord Reef NPNAT. NAROEE oKEEoaB N - cwN v COUNTY °uNTY s„HT F O A mkHasptd UCIE Renna'S Pi ZLa ' Gat oESOTo co w muNn Monahan Jewelers v� tvd t� SARASOTA COUNTY Crvlche Jex Q „NTY CCVN1 � couNTr .NARLOTTE OAOEs ATM couwTv —KITY Coral Reef VICINITY MAP PALM Animal Hospital V'E 100 SEMINOLE RD,ATLANTIC BEACH,FL EE N r m Y Li fait CouNTY 10 JOB NUMBER: 819801 PROJECT TOTALS COLER COUN rii° couNTy PROPOSED AERIAL CATVflBER p• PROPOSED AERIAL RISER FOOTAGE 0' YGNRa .JOB SITE: PROPOSED UG CATV/FIBER s0' 0O11NTY YNMLOAOE muNTY 100 SEMINOLE RD,ATLANTIC BEACH, FL TOTAL FOOTAGE so, TOTAL PROPOSED BORES 0• TOTAL EXISTING PED 0' IN //�� r�v�///�����a © OONCReTE POS ©NAUT PROPOSED AERIAL&UG CAN I FIBER �OIf (�l�(( 11 \� ATLANTIC BEACH erREET Lahr X —KrT usAaE Pat YANONOR FACILITIES IN DUVAL COUNTY,FLORIDA U U U ��J LJJ���ppp X wxo vow ❑reocsra W E RIGHT-OF-WAY — .__ ..—...— ® mANCFOIe.ERPat >= aavERT vpr�mvEw crtr ATw+TCBEww 5934 RICHARD ST PERMIT WATER NA R--- ® RISER POLI — ae cwNT —AL SULE T'iOSULE STATE Y FLORIW S JACKSONVILLE,FLORIDA 32216 RANT oc war ------ 0 --SO 1 DATE Nett 11 DRAWN ceERCdYE GRouP NOTES ALL PROPOSED CONSTRUCTION WILL BE PER ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY THE ATLANTIC BEACH SPECIFICATIONS AS WELL AS WILL BE RESTORED TO ORIGINAL OR BETTER ALL UTILITIES LOCATED BY VISUAL INSPECTION,TBE ALL NECESSARY SAFETY CODES. CONDITION BY GRADING AND RE-SODDING.SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH VERIFIED BY LOCATES ALL PROPOSED CATV WILL BE WITHIN THE ATLANTIC BERMUDA SOD."ALL CRACKED SIDEWALK IS TO BE EDT REPRESENTS EDGE OF BEACH RIGHT-OF-WAY. REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF TRAVEL NOT TRUE EDGE of PAVEMENT WORK COMPLETION." ALL PROPOSED UNDERGROUND CATV WILL BE E/P REPRESENTS THE TRUE BURIED A MINIMUM OF 36"DEEP EXCEPT ROAD BORES WORK OPERATIONS ARE TO BE MINDFUL NOT TO EDGE OF PAVEMENT 60"DEEP AND DRIVEWAY BORES AT 60"DEEP. DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EOD REPRESENTS THE EDGE EQUIPMENT.ANY DAMAGE INCLUDING TRACK MARKS OF DIRT ALL PROPOSED UNDERGROUND CAN ROAD BORES WILL BE REPAIRED OR REPLACED BY THE HAND DIG TRENCHES 36"DEEP WILL USE CITY APPROVED DIRECTIONAL BORE CONTRACTOR. ACROSS DIRT ROAD MACHINE,AS WELL AS COUNTY APPROVED CONDUIT. CONSTRUCTION NOTES ALL PROPOSED CAN ROAD BORES WILL EXTEND A MINIMUM OF 8'BEYOND THE EDGE OF PAVEMENT. IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN ALL PROPOSED CAN DRIVEWAY BORES WILL EXTEND THE RIGHT-OF-WAY AND EASEMENTS.THE A MINIMUM OF 6'BEYOND THE EDGE OF PAVEMENT. PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK ALL PROPOSED BORES WILL BE IN A(4'X4'X4')PIT THROUGH FIELD VERIFICATION OF THE AND WILL USE(2)2"HDPE CONDUIT AT 48"DEPTH LOCATION OF THE EXISTING UTILITIES IN USING A 5 1/4"DRILL HEAD. CASE OF OPEN EXCAVATION.VERIFICATION MAY BE PERFORMED DURING THE ALL PROPOSED AERIAL WILL BE.700"DIAMETER AND PERMITTEES WORK.IN THE CASE OF WILL BE LASHED TO.250"STEEL STRAND CABLE DIRECTIONAL DRILLING,VERIFICATION SHALL USING.125"STANDARD GALVANIZED LASHING WIRE. TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT. ALL PROPOSED AERIAL CAN CROSSING ROADWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0" THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO ALL PROPOSED AERIAL CAN CROSSING DRIVEWAYS AVOID CONTACT WITH DETECTION WILL HAVE MINIMUM MID-SPAN HEIGHT OF 16'-0" EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL RGH LOCATES WILL BE REQUIRED IN ALL PROPOSED NOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO AND GROUND PENETRATION RADAR(GPR). CONSTRUCTION. THE EXCAVATOR SHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/ NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE STATE INFRASTRURE AND THE EXISTING MADE PRIOR TO CONSTRUCTION. FACILITIES OF THE OTHER UTILITY COMPANIES N < IbHCREIE POLE coofficast PROPOSED AERIAL 6 UG CATV/FIBER ATLANTIC BEACH EET L1OHi � - X JO►+T uuaE POEE Y/,NCROR FACILITIES INDWAL COUNTY,FLORIDA W E X WOO�FOLE [-IREOEST. CgMTRucibR (]tv urtK BE/.CR RIGHT-OF-WAY _ _ ._,,,_ ® TRMDIO RRIXE ry -VERT ­ 5934 RICHARD ST PERMIT ��-R „<reR ® MER ROIE T BCIiEeCKE p.n � OWb. JACKSONVILLE,FLORIDA 32216 0 •xnc�soRE v�* ure reER mRE aRan N i POWER 21'EOP 100 SEMINOLE RD - isthi � � / / % WN E CA15'EOP / O / /; i �'y� / ATLANTIC BEACH - FL�/ y � s i eo• 1 OF ' ,3 , 1 ; � l PHONE 14'EO �01 10 + % % BEGIN PROJECT WATER 5'EOP �f 30. EXISTING PED CATV 9'EOP — CATV/FIBER FACILITIES r1 [ / GPS COORDINATES J v N 30.3252950 / ,I SSURO\ W-81.4057983 RUN LINE 16'EOP SrU FOP O/W %' END PROJECT % / RO/�gNr4LF EXISTING PED RUN LIN T EO ' OP EXISTING Ony CAN/FIBER FACILITIES GPS COORDINATES N 30.3251859 Q1�N1 f W-81.4058416 �i i S�V� f Q 2 � O h O � I 4 DN'/ K FLORIDALORIDA STATE ROAD AIA LORIDA STATE ROAD AIA r r 1 J FLORIDA STATE ROAD AIA FLORIDA STATE ROAD AIA N © wr¢nare Rou[ ©vwlt PROPOSED AERIAL 8 UG CATV I FIBER coo ,I�� ATLANTIC BEACH s eET uc�T .. ^- X .,oRrt us�E RaE Y P��+ FACILITIES INDWAL COUNTY,FLOIDA w ® E 1\�J u u U u.l RIGHT-OF-WAY H --—ER- _ X w000v«E ❑.EOE:nu R cw a .Tw Kx 5934 RICHARD ST PERMIT O , EORR.ER R«E p wlveR —E � R RISER FOIE SCµE –T.— S.re nORlw S JACKSONVILLE,FLORIDA 32216 R-1 –1 ---- 0 1—SORE- — –.– I ORnMw Ex ER COREOROW i 100 SEMINOLE RD,ATLANTIC BEACH,FL o CROSS SECTION go, — 40' - 40' —SII U —30 '— IT to 2' 2"- 1 E 36" 21' A 36"— 9 —`t8" 14' I � 8„ 21' � U �0., 11 011 I a a a d W W yOj W W w O C w O 0 U S Q Q 2 O o I 0 w N O 0 O K a N •.,-K+- © Pau: ©—T PROPOSED AERIAL S UG CAN/FIBER ATLANTIC BEACH aeEruwrt --::.t—s4—u— FRaoscoT¢.El B- X pEG�aE E y ucpR FACILITIES INDWALCOUNTY,FLOIDA -EGTS E -.- ._..___._ x MOOD POL! �P.—ERI CRWEECw p �RurtC lE cq RIGHT-OF-WAY PgCWiEEO HORE —CB—OB—OF.— ® TRAN6PORMER POLE ]p CULVER 5934 RICHARD ST PERMIT 0 MER POLE BONE ar�rE gaga S JACKSONVILLE,FLORIDA 32216 .1-TOE wRr O ncnw•BaRE Prt �.h �1op'PE ROAD WORK END AHEAD ROAD NARK A o- • • ■ • • • • • • ■ ■ y q 8 TAPEa ieNGTn.1m WORK AREA 9EE LAKE II END ROAD NAJRK ROAD DEVICE SPACNGTAPER DEVICE 9PACMGTANOeM e9v WORK see T.aIEI MTAKEI AHEAD sIEEnnsE laEs TABLE 11 Taper Length-Shoulder 1nL(2) Table I q—F Nero• halo r 1b• Ir Device Spacing sNa sola sNa. Mu.INst a 6eMe■a'.W) zr 1 Ir u• u Trp I>Trp.r DISTANCE BETWEEN SIGNS ) `""`°' erdedr er wroer 'So• p' fm- 2�' TrtlWerMMen PerM aDruir 35 SSspeed IFI) T-,g- T.pr irp•re 8 10' 7Yn 2s w ss so200 200IS 1$r sa 1ar)055' L—WS ISO beyoM IIIc ROADwVRKAHEAD,pn errrdxoY BO' 190'85' 1)s' 70' 131 251' 230' e' ---wan GENERAL NOTES DURATION NOTES n1=r gm RY a ro Hn r,A.m r« SYMBOLS I Signs srM aKri2 np devirxs may be-Wedel Vof tM ® 11brll Ain I.When row or more nark verhides�aw the through tale@[lams in a one how fdlowing,-dit oro are met: •*esmn of torr snouM.r m teal p-od or bas(..vLeI g Ostabh t m aw tmminring the.area).rhe adv 1 Work operffiions re 60 MIU s o,less (combead pved.nd wlp.vee widrnl FLAGGER sign shall be sibshfa d las the WORKERS signfor locrlon of flaggers b Vehides rn the wwk area have N lO,&nsay. ■ Ch.niklmig Desna Is«rrw.x 102-1oo) w d FLAGGER signs.see inder m.102-603. rotating. 1.st g,oscillriny,or strobe lights s=pv.d sped rlme trop) rrII,, 2.SHOULDER wwk sgn may be used es art aRemsfe to the WORKER symbol slgn only operanrg Ly wan zone Son on the side whers the shoJder wwk is being polormed b t.ro Iden9/rr.non.os«w�of inlec 3.Wtlen a side road irderseIXs the highway-t-the TTC Ions,ad&. TTC devices shall be plaoee in--d—-h other aparafl-TCZ indexes. CONDITIONS 4 For gernrsl TCZ,"-emems and addd,-M Infom is—refer fO Index 102-600 WHERE ANY VEHICLE,EQUIPMENT.WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER THAN 15'BUT NOT CLOSER THAN 2' TO THE EDGE OF TRAVEL WAY DESCRIPTION INDEX LAST FY 2019-20 SHEET F0 REVISION STANDARD PLANS TWO-LANE,TWO-WAY, WORK ON SHOULDER 5of6 011101117102-602 10,000"'— THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION 2019-2020 102-600 INDEX AND APPLY TO 100 SEMINOLE RD, ATLANTIC BEACH , FL • STANDARD PLANS INDEX NO 102-602 (TWO-LANE,TWO-WAY, WORK ON SHOULDER) IN //�� /�/� Cn7 - © O RM POLE w VAULT PROPOSED AERIAL&UG CAN/FIBER /l"�I(1(ll�// \I�� ATLANTIC BEACH snEET uor.r `R°F'O'E�� r " - X JO�MT USAGE POLE Y AR�R�R FACILITIES IN DUVAL COUNTY,FLOIDA W ® E l``/, u u u \\�-/ill 'x E ..E.-._F - RROPO EO [Ki+- .... �( y�ppp POLE PEDESTAL TRHFEIC LOMROL RULE&Ot —1 LnR11C RIGHT-OF-WAY a,. ,w ® TRAH9EORMFR ROIE ,> CULVERT SREEi R� 5934 RICHARD ST PERMIT ,AzR TER— ® ­ER E ISTATE. EL a S JACKSONVILLE.FLORIDA 32216 M-TOEVUY ---- 0 fl(fXl EORE PR o.Te EiEEacoRECRow