Loading...
1057 Beach Ave (2005) Water Impact Fee/Energy WATER IMPACT FEE WORKSHEET c ADDRESS: 6 S C/}cff OF .T ,D %o T� J F� DRAINAGE FIXTURE UNIT FIXTURE TYPE VALUE AS LOAD FIXTURES UNITS Automatic clothes washers,commercial 3 Automatic clothes washers, residential 2 Bathroom group consisting of water closet, lavatory, � � 2— Bidet, Bidet, and bathtub or shower 6 Bathtub (with or without overhead shower or whirlpool attachments) 2 _ Bidet 2 Combination sink and tray 2 Dental lavatory 1 Dishwashing machine,domestic 2 Drinking fountainAcemaker Yz Floor drains 2 Hose bib 1 Kitchen sink, domestic 2 Kitchen sink, domestic with focd waste grinder and/or dishwasher 2 Laundry tray(1 or 2 compartments) 2 Z Lavatory 1 Shower compartment, domestic 2 2 Sink 2 Z Urinal 4 Urinal, 1 gallon per flush or less 2 Wash sink(circular or multiple)each set of faucets 2 Water closet,flushometer tank, public or private 4 Water closet, private installation 4 Water closet, public installation 6 TOTAL NUMBER OF UNITS= MULTIPLIED X 20 TOTAL$ O FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name Loff addition Builder: Fasannelli Dev Address: 1057 Beach Ave Permitting Office Atlantic Beach City, State: Atlantic beach, FI Permit Number. Owner: Loff Jurisdiction Number: 261400 Climate Zone: North 1. New construction or existing Addition _ 12. Cooling systems 2. Single family or multi-family Single family _ ! a. Central Unit Cap:30.0 kBtu/hr _ 3. Number of units,if multi-family I _ SEER: 12.00 _ 4. Number of Bedrooms I _ b. Central Unit Cap:36.0 kBtu/hr 5. Is this a worst case? No _ ( SEER: 12.00 _ 6. Conditioned floor area(ft2) 2884 ft2 I c. Central Unit Cap: 18.0 kBtu/hr 7. Glass area&type Single Pane Double Pane _ SEER: 12.00 _ a. Clear glass,default U-factor 0.0 ft2 618.0 ft' _ 13. Heating systems b. Default tint 0.0 ft2 0.0 ft2 _ a. Electric Heat Pump Cap:30.0 kBtu/hr _ c. Labeled U or SHGC 0.0 ft2 0.0 ft2 j HSPF:7.10 _ 8. Floor types _ b. Electric Heat Pump Cap:36.0 kBtu/hr _ a. Raised Wood,Adjacent R=19.0,248.0 ft2 _ HSPF:7.10 _ b. Slab-On-Grade Ede Insulation,0 R=0.0, 128.0 ft2 _ c. Electric Heat Pump Cap: 18.0 kBtu/hr _ c. 1 Others 42.0 ft2 HSPF:7.10 _ 9. Wall types _ 14. Hot water systems a. Frame,Wood,Exterior R=11.Q 2211.0 ft2 _ a. Electric Resistance Cap:2.0 gallons b. Frame,Wood,Adjacent R=11.0,312.0 ft2 _ EF:0.90 _ c. N/A b. Electric Resistance Cap:2.0 gallons _ d. N/A _ EF:0.90 _ e. N/A c. Conservation credits _ 10. Ceiling types I (HR-Heat recovery.Solar a. Under Attic R=30.0, 1458.0 ft2 _ DHP-Dedicated heat pump) b. Under Attic R=19.0,70.0 ft2 _ j 15. HVAC credits c. N/A i (CF-Ceiling fan,CV-Cross ventilation, IL Ducts _ HF-Whole house fan, a. Sup:Unc. Ret:Con. AH:Interior Sup.R=6.0, 150.0 112 _ PT-Programmable Thermostat, b. 2 Others 225.0 ft MZ-C-Multizone cooling, MZ-H-Multizone heating) i Glass/Floor Area: 0.21 Total as-built points: 32251 n n A Total base points: 33695 PASS I hereby certify that the plans and specifications covered I Review of the plans and by this calculation are in compliance with the Florida specifications covered by this �o4�KEs�gTICIo Energy Code. � calculation indicates compliance .�\ with the Florida Energy Code. « _ -• - ; ;•. o 11 PREPARED B�: Before construction is completed x ­'��''I o DATE: this building will be inspected for I hereby certify that this building, as designed, is in compliance with Section 553.908 compliance with the Florida Ene g Cod F ida Statutes. OWNER/AGENT: IBUILDING OFFICIAL: DATE: 5 DATE: S- / - y EnergyGauge®(Version: FLRCPB v3.30) FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 1057 Beach Ave, Atlantic beach, FI, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 2884.0 20.04 10403.2 Double, Clear S 2.0 8.0 28.0 35.87 0.86 859.8 Double, Clear SE 6.0 8.0 50.0 42.75 0.55 1182.6 Double, Clear E 12.0 8.0 39.0 42.06 0.43 710.2 Double, Clear NE 6.0 8.0 50.0 29.56 0.65 958.6 Double, Clear E 12.0 8.0 27.0 42.06 0.43 491.7 Double,Clear E 12.0 8.0 15.0 42.06 0.43 273.2 Double, Clear N 2.0 16.0 20.0 19.20 0.99 380.6 Double,Clear W 2.0 8.0 58.0 38.52 0.91 2040.8 Double, Clear S 2.0 8.0 30.0 35.87 0.86 921.2 Double,Clear E 10.0 8.0 45.0 42.06 0.46 876.6 Double,Clear N 24.0 8.0 15.0 19.20 0.59 170.8 Double,Clear E 12.0 8.0 20.0 42.06 0.43 364.2 Double, Clear E 12.0 8.0 50.0 42.06 0.43 910.5 Double, Clear N 2.0 8.0 30.0 19.20 0.94 540.7 Double, Clear W 6.0 8.0 15.0 38.52 0.60 348.1 Double, Clear S 2.0 8.0 50.0 35.87 0.86 1535.4 Double,Clear E 12.0 8.0 25.0 42.06 0.43 455.3 Double,Clear E 12.0 8.0 15.0 42.06 0.43 273.2 Double,Clear E 2.0 8.0 10.0 42.06 0.91 383.9 Double.Clear N 2.0 8.0 10.0 19.20 0.94 1802 Double,Clear W 2.0 8.0 12.0 38.52 0.91 422.2 Double,Clear N 2.0 8.0 4.0 19.20 0.94 72.1 As-Built Total: 618.0 14352.1 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 312.0 0.70 218.4 Frame,Wood, Exterior 11.0 2211.0 1.70 3758.7 Exterior 2211.0 1.70 3758.7 Frame,Wood,Adjacent 11.0 312.0 0.70 218.4 Base Total: 2523.0 3977.1 As-Built Total: 2523.0 3977.1 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 38.0 2.40 91.2 Exterior Wood 170.0 6.10 1037.0 Exterior 170.0 6.10 1037.0 Adjacent Wood 38.0 2.40 91.2 Base Total: 208.0 1128.2 1 As-Built Total: 208.0 1128.2 EnergyGauge@ DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 1057 Beach Ave, Atlantic beach, FI, PERMIT#: BASE AS-BUILT CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1428.0 1.73 2470.4 Under Attic 30.0 1458.0 1.73 X 1.00 2522.3 Under Attic 19.0 70.0 2.34 X 1.00 163.8 Base Total: 1428.0 2470.4 As-Built Total: 1528.0 2686.1 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 128.0(p) -37.0 -4736.0 Raised Wood, Stem Wall 19.0 42.0 -1.50 -63.0 Raised 290.0 -3.99 -1157.1 Raised Wood,Adjacent 19.0 248.0 0.40 99.2 Slab-On-Grade Edge Insulation 0.0 128.0(p -41.20 -52736 Base Total: -5893.1 As-Built Total: 418.0 -5237.4 INFILTRATION Area X BSPM = Points Area X SPM = Points 2884.0 10.21 29445.6 2884.0 10.21 29445.6 Summer Base Points: 41531.4 Summer As-Built Points: 46351.8 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 46351.8 0.357 (1.000 x 1.147 x 0.86) 0.284 1.000 4932.0 46351.8 0.429 (1.081 x 1.147 x 0.86) 0.284 1.000 5918.4 46351.8 0.214 (1.090 x 1.147 x 0.86) 0.284 1.000 2959.2 41531.4 0.4266 17717.3 46351.8 1.00 1.048 0.284 1.000 13809.5 EnergyGaugeT" DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 1057 Beach Ave, Atlantic beach, FI, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point 18 2884.0 12.74 6613.6 Double,Clear S 2.0 8.0 28.0 13.30 1.12 416.1 Double,Clear SE 6.0 8.0 50.0 14.71 1.68 1236.4 Double. Clear E 12.0 8.0 39.0 18.79 1.39 1018.7 Double,Clear NE 6.0 8.0 50.0 23.57 1.04 1221.8 Double, Clear E 12.0 8.0 27.0 18.79 1.39 705.3 Double, Clear E 12.0 8.0 15.0 18.79 1.39 391.8 Double,Clear N 2.0 16.0 20.0 24.58 1.00 491.4 Double, Clear W 2.0 8.0 58.0 20.73 1.02 1230.5 Double, Clear S 2.0 8.0 30.0 13.30 1.12 445.8 Double, Clear E 10.0 8.0 45.0 18.79 1.35 1139.7 Double, Clear N 24.0 8.0 15.0 24.58 1.03 378.7 Double,Clear E 12.0 8.0 20.0 18.79 1.39 522.4 Double,Clear E 12.0 8.0 50.0 18.79 1.39 1306.0 Double,Clear N 2.0 8.0 30.0 24.58 1.00 739.1 Double,Clear W 6.0 8.0 15.0 20.73 1.13 352.8 Double.Clear S 2.0 8.0 50.0 13.30 1.12 743.1 Double, Clear E 12.0 8.0 25.0 18.79 1.39 653.0 Double, Clear E 12.0 8.0 15.0 18.79 1.39 391.8 Double, Clear E 2.0 8.0 10.0 18.79 1.04 194.6 Double, Clear N 2.0 8.0 10.0 24.58 1.00 246.4 Double,Clear W 2.0 8.0 12.0 20.73 1.02 254.6 Double,Clear N 2.0 8.0 4.0 24.58 1.00 98.5 As-Built Total: 618.0 14178.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 312.0 3.60 1123.2 Frame,Wood, Exterior 11.0 2211.0 3.70 8180.7 Exterior 2211.0 3.70 8180.7 Frame,Wood,Adjacent 11.0 312.0 3.60 1123.2 Base Total: 2523.0 9303.9 As-Built Total: 2523.0 9303.9 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 38.0 11.50 437.0 Exterior Wood 170.0 12.30 2091.0 Exterior 170.0 12.30 2091.0 Adjacent Wood 38.0 11.50 437.0 Base Total: 208.0 2528.0 As-Built Total: 208.0 2528.0 EnergyGaugeg DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 1057 Beach Ave, Atlantic beach, FI, PERMIT#: BASE AS-BUILT CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1428.0 2.05 2927.4 Under Attic 30.0 1458.0 2.05 X 1.00 2988.9 Under Attic 19.0 70.0 2.70 X 1.00 189.0 Base Total: 1428.0 2927.4 As-Built Total: 1528.0 3177.9 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 128.0(p) 8.9 1139.2 Raised Wood.. Stem Wall 19.0 42.0 0.80 33.6 Raised 290.0 0.96 278.4 Raised Wood,Adjacent 19.0 248.0 2.20 545.6 Slab-On-Grade Edge Insulation 0.0 128.0(p 18.80 2406.4 Base Total: 1417.6 As-Built Total: 418.0 2985.6 INFILTRATION Area X BWPM = Points Area X WPM = Points 2884.0 -0.59 -1701.6 2884.0 -0.59 -1701.6 Winter Base Points: 21088.9 Winter As-Built Points: 30472.5 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 30472.5 0.357 (1.000 x 1.169 x 0.88) 0.480 1.000 5627.3 30472.5 0 429 (1.060 x 1.169 x 0.88) 0.480 1.000 6752.8 30472.5 0.214 (1.069 x 1.169 x 0.88) 0.480 1.000 3376.4 21088.9 0.6274 13231.2 30472.5 1.00 1.077 0.480 1.000 15756.5 EnergyGauge-14 DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details r ADDRESS: 1057 Beach Ave, Atlantic beach, FI, PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2746.00 2746.0 2.0 0.90 1 0.50 2684.98 1.00 1342.5 2.0 0.90 1 0.50 2684.98 1.00 1342.5 As-Built Total: 2685.0 CODE COMPLIANCE STATUS BASE AS-BUILT Coolina + Heatina + Hot Water = Total Cooling + Heatina + Hot Water = Tntal Points Points Points Points Points Points Points Points 17717 13231 2746 33695 13810 15756 2685 32251 PASS. OggHE Srqj, OL) EnergyGauge•'" DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS 1057 Beach Ave, Atlantic beach, FI, PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST ------------------ COMPONENTS _ SECTION REQUIREMENTS FOR EACH PRACTICE N, CHECK Exterior Windows&Doors- {606.1.ABC 1.1 Maximum:.3 cfm/sq.ft,window area .5 cfm/sq_ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; i foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations; between wall panels&top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the top plate. _ Floors 606,I.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor,around shafts,chases, soffits,chimneys, cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. _ Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC that with no penetrations, sealed;or Type IC or non-IC rated, installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. —._ —. - - - --- ----- Additional Infiltration reqts 1 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES(must-be met-or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly marked circuit breaker(electric)or cutoff(gas)must be provided. External or built-in heat trap required._ Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal I efficiency of 78%. Shower heads ;612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings, mechanical equipment and plenum chambers shall be mechanically j attached,sealed, insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-11. EnergyGauge71� DCA Form 60OA-2001 EnergyGauge�/FIaRES'2001 FLRCPB v3.30 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* =83.2 The higher the score,the more efficient the home. Loff, 1057 Beach Ave, Atlantic beach, FI, 1. New construction or existing Addition 12. Cooling systems 2. Single family or multi-family Single family - a. Central Unit Cap:30.0 kBtu/hr _ 3. Number of units,if multi-family I - SEER: 12.00 _ 4. Number of Bedrooms 1 _ b. Central Unit Cap:36.0 kBtu/hr _ 5. Is this a worst case? No _ SEER: 12.00 _ 6. Conditioned floor area(ft2) 2884 ft' c. Central Unit Cap: 18.0 kBtu/hr _ 7. Glass area&type Single Pane Double Pane _ SEER: 12.00 _ a. Clear-single pane 0.0 ft' 618.0 112 _ 13. Heating systems b. Clear-double pane 0.0 ft2 0.0 112 _ a. Electric Heat Pump Cap:30.0 kBtu/hr c. Tint/other SHGC-single pane 0.0 ft2 0.0 ft2 _ HSPF:7.10 _ d. Tint/other SHGC-double pane b. Electric Heat Pump Cap:36.0 kBtu/hr _ 8o r«; 's _ HSPF:7.10 _ a. Raised Wood,Adjacent R=19.0,248.0 ft2 _ c. Electric Heat Pump Cap: 18.0 kBtu/hr - b. Slab-On-Grade Edge insulation,0 R=0.0, 128.0 ft2 _ HSPF:7.10 _ c. 1 Others 42.0 ft' 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap:2.0 gallons _ a. Frame,Wood,Exterior R=11.0,2211.0 ft2 _ EF:0.90 _ b. Frame,Wood.Adjacent R=11.0,312.0 ft2 _ b. Electric Resistance Cap:2.0 gallons _ c. N/A _ EF:0.90 _ d. N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0, 1458.0 1112 _ 15. HVAC credits _ b.Under Attic R=19.0,70.0 ft2 _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Con. AH:Interior Sup.R=6.0, 150.0 ft2 _ MZ-C-Multizone cooling, b. 2 Others 225.0 ft M7_-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) ,THE sT in this home before final inspection.Otherwise,a new EPL Display Card will be completed �04 �r�o� based on installed Code compliant features. Builder Signature: Date: I Address of New Home: City/FL Zip:_ f'1'COD WE *NOTE: The home's estimated energy performance scare is only available through the FLA/RES computer program. This is not a Building Energy Rating. ff your score is 80 or greater(or 86 for a US EPA/DOE EnergyStar'Mdesignation), your home may qualify for energy e#z'ciency mortgage(EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. EnergyGauge®(Version:FLRCPB v3.30) RIGHT-J LOAD AND EQUIPMENT SUMMARY Zone One Energy Design Systems Job: 3/3/05 1065 Oak Vale Rd,Jacksonville.FI 32259 Phone.904-287-5339 Fax 904-287-1258 Email energydesign@comcast net "Project • Information 11 For: Loff addition 1057 Beach Ave, Atlantic beach, FI Notes.- Design, • • Weather: Jacksonville, Mayport Naval, FL , US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 92 OF Inside db 72 OF Inside dh 74 OF Design TD 33 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 16912 Btuh Structure 19735 Btuh Ventilation air 0 cfm Ventilation 0 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF nesion heat load 16912 Btuh Use mfadata n Rate/swing multiplier 0.97 Infiltration Total sens. equip. load 19143 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 460 Btuh Ventilation 0 Btuh Heating Cooling Infiltration 2665 Btuh Area (ft') 875 875 Total latent equip. load 3125 Btuh Volume (ft') 7656 7656 Air changes/hour 0.87 0.51 Total equipment load 22268 Btuh Equiv. AVF (cfm) 111 65 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a n/a n/a n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 0 cfm Actual cooling fan 0 cfm Heatina air flow factor 0.000 cfm/Btuh Coolino air flow factor 0.000 cfm/Btuh Space thermostat n/a Load sensible heat ratio 0 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ,$j WYIC)htSC,ft Right-Suite Residential'"5.0.66 RSR29784 2005-Mar-03 09'31:01 AC CA C-\Documents anrd.S'ettings\customer\My DocumentsMrightsoft1off add 1057 Beach Ave Atl Bch.rsr Page 1 RIGHT-J LOAD AND EQUIPMENT SUMMARY Zone Two Energy Design Systems Job: 313105 1065 Oak Vale Rd.Jacksonville,FI 32259 Phone 904-287-5339 Fax:904-287-1258 Email:energydesigii@comcast.net Project Information For: Loff addition '105 1 Beach Ave, Atlantic beach, A Notes: Design informatin Weather: Jacksonville, Mayport Naval, FL , US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 92 OF Inside db 72 OF Inside db 74 OF Design TD 33 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 21638 Btuh Structure 23267 Btuh Ventilation air 0 cfm Ventilation 0 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 21638 Btuh Use mfg. data n Rate/swing multiplier 0.97 Infiltration Total sens. equip. load 22569 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal qains 460 Btuh Ventilation 0 Btuh Heating Cooling Infiltration 3123 Btuh Area (ft') 1419 1419 Total latent equip, load 3583 Btuh Volume (ft') 13764 13764 Air changes/hour 0.57 0.33 Total equipment load 26152 Btuh Equiv. AVF (cfm) 130 76 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a n/a n/a n/a Efficiency n/a Efficiency n/a Heating Input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 0 cfm Actual cooling fan 0 cfm Heating air flow factor 0.000 cfm/Btuh Cooling air flow factor 0.000 cfm/Btuh Space thermostat n/a Load sensible heat ratio 0 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrightsoft Right-Suite Residential*^'5.0.66 RSR29784 2005-Mar-0309:31:01 ACCA C:\Documents and Settings\customer\My Documents\wrightsoft\Loff add 1057 Beach Ave Atl Bch.rsr Page 2 RICHT-J LOAD AND EQUIPMENT SUMMARY ; Zone Three Energy Design Systems Job: 3/3/05 1065 Oak Vale Rd.Jacksonville,FI 32259 Phone.904-287-5339 Fax.904-287-1258 Email:energydesign_comcast net P noject,Information For. Loff addition 1057 Beach Ave, Atlantic beach, FI Notes: Design Inf• • Weather: Jacksonville, Maypolt Naval, FL , US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 72 °F Inside db 72 'F Design TD 33 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 65 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 11966 Btuh Structure 12777 Btuh Ventilation air 0 cfm Ventilation 0 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 °F Design heat load 11966 Btuh Use mfg. data n Rate/swing multiplier 0.97 Infiltration Total sens. equip. load 12394 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 460 Btuh Ventilation 0 Btuh Heating Cooling Infiltration 1565 Btuh Area (ft') 590 590 Total latent equip. load 2025 Btuh Volume(ft') 5015 5015 Air changes/hour 0.81 0.43 Total equipment load 14419 Btuh Equiv. AVF (cfm) 68 36 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a n/a n/a n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heatinq output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 + Total cooiing 0 Btuh Actual heating fan 0 cfm Actual cooling fan 0 cfm Heating air flow factor 0 000 cfm/Rtuh ('nolinn air flnw factor 0.000 cfm/Btuh Space thermostat n/a Load sensible heat ratio 0 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wnghtsoft Right-Suite Residential 5.0.66 RSR29784 2005-Mar-03 09:31:01 ACCA c:lDocuments and Settingslcustomer\My Documentsmrightsofl\Loff add 1057 Beach Ave Atl Bch.rsr Page 3