Loading...
750 Cavalla Rd ACRS19-0301 Replacement MECHANICAL RESIDENTIAL HVAC PERMIT NUMBER ACRS19-0301 PERMIT ISSUED: 8/30/2019 CITY OF ATLANTIC BEACH EXPIRES: 2/26/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMITTYPE: DESCRIPTION: VALUE OF WORK: MECHANICAL RESIDENTIAL 750 CAVALLA RD HVAC replace 2-ton 24K-BTU AHU $2837.34 TYPE OF + + ZONING: SUBDIVISION: i • GROUP: 171365 0320 ROYAL PALMS UNIT 02A COMPANY: ADDRESS: OCEAN STATE HEAT & AIR, 1476 ATLANTIC BLVD NEPTUNE BEACH FL 32266 INC. ® OWNER: I ADDRESS: BARBAGALLO ANTHONY M 750 CAVALLA RD ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT AC AND REFRIGERATION 455-0000-322-1000 2 $16.00 FURNACES AND HEATING 455-0000-322-1000 24000 $24.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 Issued Date: 8/30/2019 1 of 2 MECHANICAL PERMIT APPLICATIO CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 \OK Ph (90=1) 247-5826 Fax (904) 247-5845 �l� JOB ADDRESS: -75 D Ccl V -, //0,— �06,,J PERMIT# AC 9 510[-D3ol PROJECT VALUE $ ��3 3 ARS# °1/S (�t REQS Air Handling Equipment Only 2Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION 4ir Conditioning_ Unit Quantity Tons Per Unit Heat: y Unit Quantit} BTU's Per Unit Seer Rating Duct Svstems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 'A 1 Heat: Unit Quantity�— BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of pians) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps " Vented Wail Furnaces Refrigerator Condenser BTU's T Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certit,that I have read this application and know the same to be true and correct. All provisions of law's and ordinances governing this work-,s ill be complied with whether specified or not. The permit does not give authority to violate the provision:of ani other statcor local law regulation construction or the performance of construction. Property OANmers Name 1 0I-N V baa-(Ou Q 6 O Phone Number i+l Mechanical Company CAPa rn P W eai. *h, !�� Office Phone Z ,k251 Fax Z��-�]�q P Co. Address: 1116 t'��i'►L I lwt-'1G 'Blvd city�whAnC State YL Zip License Holder(Print): �. C Ttate—rti lea eaistration C►�Gd 3 r Holder ,Y" YVETTE P.MORALES z PNotaryPublic-StateofFloridaBe re me dayO Commission#GG 069102 M Comm,Ex ires Mar 2,2021 FOGP1.",`' y P Slature ob Oonded through National Notary Assn. www.aliridireetory.org Certificate of Product Ratings AHRI Certified Reference Number:9154698 Date:08-30-2019 Model Status:Active AHRI Type:HRCU-A-CB Series:COMFORT15 HP Outdoor Unit Brand Name:CARRIER Outdoor Unit Model Number (Condenser or Single Package):25HBC524A'030' Indoor Unit Model Number(Evaporator and/or Air Handler):FX4DNF025L The manufacturer of this CARRIER product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2,Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh:24000 WAS SEER: 15.00 EER(A2)-Single or High Stage(95F):12.50 Heating Capacity(H12)-Single or High Stage(47F):24000 HSPF(Region IV):8.50 t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still sell Ratinnosorhaffearrne gam nied by WAS indicate an involuntary re-rate. The new published ratina is shown alono with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for. the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrid[rectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced:copied;disseminated: entered Into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AM personal and Confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org.click on"Verify Certificate"link i,,snake hie better- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. g g g CERTIFICATE NO.: 132116426907400493 ©2019Air-Conditionin , Heating, Refri eration Institute