36 Dudley St RES19-0059 Upgrade Bldg Alterations (8/14/19)GENERAL NOTES 1. CODES USED: 2017 FLORIDA BUILDING CODE (6TH EDITION), ACI, NDS, APA AND ASCE 7-10. ALL LATEST EDITIONS USED. 2. ALL DESIGN, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION OVER THE WORK. 3. THE CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE E.O.R. IF THERE ARE CONFLICTS BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND THE EXISTING SITE CONDITIONS. DESIGN SPECIFICATIONS: A DESIGN CODE: 2017 FLORIDA BUILDING CODE (6TH EDITION) - EXISTING BUILDING - R AIR & ALTERATION LEVEL II OCCUPANCY: RESIDENTIAL GROUP R-3 (ONE AND TWO-FAMILY DWELLINGS) CONSTRUCTION: TYPE V BASIC WIND SPEED: 130 MPH (ULT.) RISK CATEGORY: II WIND EXPOSURE: B INTERNAL PRESSURE COEFFICIENT: 0.18 ENCLOSED BUILDING MAXIMUM (ULT.) DESIGN WIND PRESSURES (PSF): (WIND-BORNE DEBRIS PROTECTION NOT REQUIRED) OPENING SIZE (SF) EDGE ZONES (3'-0" FROM OUTSIDE CORNERS) INTERIOR ZONE 0-10 +30.4 and- 40.7 +30.4 and - 33.0 11-20 +29.0 and -338.0 +29.0 and -331.6 21-50 +27.2 and -34.3 +27.2 and -29.8 51-100 +25.9 and �-�25.2 -31.6 +25.9 and -28.4 �-�25.2_ >100 +22.7 and +22.7 and v NOTE: THE COMPONENT AND CLADDING (ULT.) WIND PRESSURES LISTED ABOVE MAY BE MULTIPLIED BY 0.6 TO OBTAIN THE (ALLOWABLE) WIND PRESSURES AS SPECIFIED IN THE FBC AND ASCE 7-10. DESIGN LIVE LOADS: ROOF: 20 PSF STEEL REINFORCEMENT: REINFORCING STEEL: SHALL BE ASTM A615, GRADE 60 STEEL REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE FBC, ACI 318 AND AS NOTED IN THESE PLANS. MASONRY REINFORCEMENT LAP SHALL BE MIN. 24". CONVENTIONAL WOOD FRAMING: ALL NEW WOOD FRAMING MEMBERS SHALL BE (SYP #2) & IN ACCORDANCE WITH THE FBC, EXCEPT AS NOTED ON THESE PLANS. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. ALL WOOD EXPOSED TO THE ELEMENTS SHALL BE PRESSURE TREATED. METAL CONNECTORS: ALL METAL CONNECTORS SHALL BE SIMPSON STRONG -TIE CONNECTORS UNLESS OTHERWISE APPROVED BY THE ENGINEER OF RECORD (E.O.R.) METAL CONNECTORS: ALL METAL CONNECTORS SHALL BE GALVANIZED OR STAINLESS STEEL. NAILS: ALL NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED OR STAINLESS STEEL. ALL METAL CONNECTORS SHALL BE INSTALLED WITH THE QUANTITY AND SIZE OF FASTENERS LISTED IN THE CURRENT SIMPSON CATALOG UNDER THE "MAX." FASTENING CONFIGURATION UNLESS NOTED OTHERWISE ON THESE DRAWINGS. ROOF DECKING & ATTACHMENT: FASTEN EA. EXIST. T&G ROOF DECK BOARD TO EA. RAFTER w/(2) 8d x 2j" RINGSHANK NAILS. ANCHORING ADHESIVE: ANCHORING ADHESIVE: SHALL BE THE FOLLOWING PRODUCT (DUAL CARTRIDGE INSTALLATION ONLY): * SIMPSON STRONG -TIE CO., PRODUCT: SET -XP FOLLOW ADHESIVE MFG. GUIDELINES FOR ANCHOR BOLT HOLE SIZE & PRE -CLEANING OF EPDXY ANCHOR HOLES AND INSTALLATION PROCEDURES. GROUT: THE GROUT SHALL BE IN ACCORDANCE WITH ASTM C 476 AND SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE OF 3/8" PLACED AT AN 8" TO 11" SLUMP AND HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS WHEN TESTED IN ACCORDANCE WITH ASTM C 1019. MASONRY CONSTRUCTION: CONCRETE MASONRY UNITS: SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C 90 AND SHALL HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1900 PSI WHEN USING TYPE M OR S MORTAR (ASTM C 270) IN ACCORDANCE WITH ACI 530, THE 1900 PSI BLOCK IN COMBINATION WITH TYPE M OR S MORTAR PROVIDES A DESIGN COMPRESSIVE STRENTH (f'm) OF 1500 PSI. SEE SECTION ABOVE FOR GROUT SPECIFICATIONS MASONRY CONSTRUCTION AND INSPECTION GUIDELINES: 1. LAY UP MASONRY WITH SIZE OF BLOCK AS SPECIFIED ON PLAN. 2. FACE SHELLS OF BED JOINT SHALL BE MORTARED. 3. WEBS SHALL BE MORTARED AT CELLS TO BE GROUTED. 4. VERTICAL CELLS ARE TO BE ALIGNED WHERE THEY ARE TO BE GROUT FILLED. 5. MAINTAIN MINIMUM OF 1/2 INCH (12.7 MM) COVER ON JOINT REINFORCING TO EXTERIOR AND REINFORCING SHALL BE EMBEDDED IN MORTAR. 6. GROUT SPACES ARE TO BE SUBSTANTIALLY FREE OF DROPPINGS, DEBRIS, LOOSE AGGREGATE AND ANY MATERIAL DELETERIOUS TO MASONRY GROUT. 7. INSTALL REINFORCING IN GROUT CELLS PRIOR TO GROUTING. 8. GROUT SPACES ARE TO BE INSPECTED PRIOR TO PLACING GROUT. 9. FILL CELLS AS NOTED ON THE PLANS, ELEVATIONS AND DETAILS. 10. FOR PLACEMENT OF GROUT IN LIFTS UP TO 60 INCHES IN HEIGHT (CLEAN OUT HOLES ARE NOT REQUIRED). 11. A REINFORCING BAR MAY BE USED TO ROD GROUT IN CELL, TO ENSURE THERE ARE NO VOIDS IN GROUT. 12. PLACE REINFORCING APPROXIMATELY 1 INCH (25 MM) TO THE SIDE OF DOWEL IN CELL (ACI 530-1.12.3.3) 13. GROUT SHOULD SET IN APPROXIMATELY 90 MINUTES DEPENDING ON GROUT SLUMP AND WEATHER CONDITIONS. 14. DO NOT BEND OR MOVE REINFORCEMENT AFTER GROUT HAS SET. 15. INSTALL ALL "WET SET" EMBED STRAPS AS SPECIFIED ON THESE DRAWINGS INTO TOP OF GROUT FILLED CELLS 16. PROVIDE LEVEL "B" QUALITY ASSURANCE, AS PER ACI 530-05 TABLE 1.15.2. t12'-7" SIMPSON HETA12 EMBED STRAP (TYP. 4 -PLACES) "WET SET" INTO GROUT FILLED CMU COL. - SEE DETAIL A/S-1 NEW 2' -6"x2' -6"x1'-0" DEEP CONCRETE I FOOTING w/(3) #4 BARS- ---r -. _ _ _ ­ ._ EA. WAY TOP & BOTT. + SEE DETAIL A/S-1 00 ---' - -� PROVIDE (1) NEW 2x6 "'--------- - -- _ (SYP #2) PLY ON E.A. ---- ---- --- SIDE OF EXIST. RAFTER t - FASTEN EA. NEW PLY REPLACE EXIST. COL. w/NEW L - - - - - - - - - - - - - - _ w/(2) 10d COMMON 806 CMU COL. w/(1) #4 ---- `--_- --" NAILS ® 8" ox, SEE BAR VERT. IN EA. CELL - DETAIL A/S-1 /-EXIST. RIDGE _ GROUT FILL ALL CELLS, SEE ;; / DETAIL A/S -1 + EXIST. BEAM (LOW) TO REMAIN �' �;�-----------. __------- "' PROVIDE (1) NEW 2x6 .II _ (SYP #2) PLY ON E.A. _ SIDE OF EXIST. RAFTER _-err_=� c-� ------ --- FASTEN EA. NEW PLY X11 w/(2) 10d COMMON NAILS @ 8" o.c. S-1 i REPLACE EXIST. COL. w/NEW 8x16 CMU COL. w/(1) #4 BAR VERT. IN EA. CELL - GROUT FILL ALL CELLS, SEE DETAIL A/S-1 NEW 2' -6"x2' -6"x1'-0" DEEP CONCRETE FOOTING w/(3) #4 BARS EA. WAY TOP & BOTT. SEE DETAIL A/S-1 #4 x 12" REBAR DOWEL EPDXIED 6" INTO EXIST. SLAB (TYP.) II INFILL EXIST. WINDOW w/WOOD FRAMING, SEE DETAIL C/S-1 yam. L L U I SIMPSON A34 CLIP ---------'- pEA. (ENDd(1NAII)S INTO PROVIDE (1) NEW 2x6 (SYP #2) PLY ON -------------- .- E.A. SIDE OF EXIST. RAFTER - FASTEN EA. NEW PLY w/(2) 1 O COMMON NAILS ® 8" o.c. SEE SIMILAR DETAIL B/S-1 ------------------ - I� L/NETYPEKEY - - - - -CONCRETE FOOTING AL INFILL -------- NEW FRAMING MEMBER N FOUNDATION & FRA MING PLAN EXIST. RAFTER (I - ___ - - - C� SOILS: ASSUMED MINIMUM ALLOWABLE SOIL BEARING CAPACITY = 2000 PSF SUBSURFACE SOIL CONDITIONS WERE NOT AVAILABLE AT THE TIME OF THIS DESIGN. THE FILL BELOW THE FOUNDATION SHOULD BE FREE OF DEBRIS, ORGANIC MATERIAL, COHESIVE SOILS OR ANY OTHER DELETERIOUS MATERIAL. SOIL MUST BE COMPACTED TO 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY FOR A DEPTH OF 2'-0" BELOW THE BOTTOM OF THE FOOTING. FOOTINGS AND FOUNDATIONS: FOOTINGS AND FOUNDATIONS SHALL BE IN ACCORDANCE WITH FBC AND AS NOTED IN THESE PLANS. WELDED WIRE REINFORCING (WWR): SHALL BE ASTM A185, FURNISHED IN FLAT SHEETS. THE BOTTOM OF ALL NEW FOOTINGS SHALL BE MIN. 12" BELOW THE TOP OF THE SURROUNDING UNDISTURBED FINISHED GRADE. CONCRETE: CAST -IN-PLACE CONCRETE: SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. CONCRETE AND STEEL REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE FBC. PROVIDE (1) NEW 2x6 (SYP #2) PLY ON E.A. SIDE OF EXIST. RAFTER - FASTEN EA. NEW PLY w/(2) 10d COMMON NAILS ® 8" o.c. B S-1 Al EXIST. CMU WALL FASTEN EA. END OF STUDS w/(3) 10d COMMON TOE -NAILS (TYP.)-,_ EXIST. OPENING TO BE INFILLED (1) J" O x 2j" TAPCON @- 12 o.c. (TYP.) SIMPSON H3 CLIP w/(8) 8d NAILS SEE DETAIL D/S-1 FOR ALLOWABLE "END CUT" PROVIDE (1) NEW 2x6 (SYP #2) PLY ON E.A. SIDE OF EXIST. RAFTER - FASTEN EA. NEW PLY w/(2) 10d -- ----- COMMON NAILS @ 8" o.c. EXIST. RAFTER _ - EXIST. WALL I PLATE OIL T.O. NEW CMU COL.L TO MATCI�- EXIST. OL. ELEV. EXIST. BEAM TO REMAIN (1) SIMPSON H3 INSTALL LAYER OF GALVANIZED CLIP w/(8) 8d NAILS FLASHING BTWN. BOTT. OF EXIST. WOOD BEAM & TOP OF (2) SIMPSON HETA12 NEW CMU COL. EXIST. EXTERIOR EMBED STRAPS "WET WALL OF SET" INTO GROUT RESIDENCE FILLED CMU - FASTEN EA. STRAP TO EXIST. BEAM 8x16 MASONRY CMU "/(7)l COL. w/(1) #4 BAR VERT. IN EA. CELL - GROUT FILL ALL TOP OF EXIST. NVI, GRADE o --_-- _ #4 x 12" REBAR DOWEL 12" HOOK INTO FTG, EPDXIED 6" INTO EXIST. SLAB NEW 2' -6"x2' -6"x1'-0" DEEP -J MUVOLUM I ROOFFRAM/NG DETAIL CONCRETE FOOTING w/(3) #4 BARS A EA. WAY TOP & BOTT. SCALE: NTS FASTEN EA. NEW PLY TO RIDGE w/(1) SIMPSON A34 CLIP w/(8) 8d NAILS EXIST. RIDGE PROVIDE (1) NEW 2x6 (SYP #2) PLY ON E.A. SIDE OF EXIST. RAFTER - FASTEN EA. NEW PLY w/(2) 10d COMMON NAILS @ 8" O.C. (1) SIMPSON H3 CLIP w/(8) 8d NAILS MATCH EXIST. _-- OVERHANG I EXIST. INTERIOR EXIST. WALL WALL PLATE EXIST. EXTERIOR WALL OF RESIDENCE ROOFFRAM/NG DETA/L SCALE: NTS OFFICE COPY MIN. P.T. 2x4 STUD PLATE AROUND PERIMETER OF OPENING MIN. 2x4 STUDS --- @ 116" o.c. (TYP.).- MIN. TYP.).--. WALL LL�11TA/L U SCALE: NTS MIN. A APA RATED WALL SHEATHING - FASTEN w/8d NAILS ® 6" o.c. EDGES & FIELD REVISION B P# jf pS! al-oc. S DATE_ / 7 / SIGNED yh L L/3 L/3 �D/3 MAX. D/3 MAX. D/6 MAX. NO NOTCHES PERMITTED D/7MAX. _ CENTER CUTS MEMBERS w/4" & GREATER NOMINAL THICKNESS IS NOT PERMITTED TO BE NOTCHED ON THIS (TENSION) SIDE OF THE MEMBER EXCEPT ® THE ENDS L L/3Ilk L/3 D/4 MAX. NO NOTCHES DIlk PERMITTED D/4 MAX. END CUTS 2" MIN. -\_BORED HOLE D D/3 MAX. 2" MIN. BORED HOLES SHALL NOT BORED HOLES ,o TVA (NOTCHING TIAL BORING LIMITS 6 h BASED EDITION ON ,f B E� L OR ON PARAGRAPH(s) R502.8.1 A!!S 21 2019 NOTCH &BORE LIMITS FOR SAN4LERnt SCALE: NTS c�y���`'' =' `-i�, FL ollod :­!­"', ■ ALLISON ENGINEERING SERVICES, PLLC P.O. BOX 8222 JACKSONVILLE, FL 32239-0222 (904)708-0966 FLORIDA COA # 31833 o� 1 REVISIONS NO. DATE Al 08.15.19 CONTRACTOR: VIRTUE CONTRACTING LLC 5960 STATE RD. 16 ST. AUGUSTINE, FL 32092 CRC 1331971 DESIGNED/DRAWN BY: JA A DATE: 08.07.19 PROJECT NO. 19-1295 sm I V z LLJ Z 0 < V) Q C Q z 0 LLJ ::2 CN W � C � v J � )- = U o U IC�_ W MM �1 p U J f- cl:� Q I-�- IJ - U Q c DESIGNED/DRAWN BY: JA A DATE: 08.07.19 PROJECT NO. 19-1295 sm I V LLJ Z 0 < V) Q C Q z 0 LLJ ::2 W � C DESIGNED/DRAWN BY: JA A DATE: 08.07.19 PROJECT NO. 19-1295 sm I