55-57 Sherry Dr Form Board 3'' ECS Florida, LLC + IM 7064 Davis Creek Road miiiii J(904)acksonville880-0960,FL[Phone:32256] LETTER OF TRANSMITTAL (904)880-0970[Fax:] September 24,2019 RE: 55 Sherry Drive Mathieu Builders ECS Job# 35:29400 38 W 9th St. Atlantic Beach, FL 32233 Permits: Location: 55 Sherry Dr. ATTN: Dustin Brown Atlantic Beach, FL We are enclosing: X Field Reports X For your use X As requested ENCL: Field Report# 1 09/19/2019 Disclaimer 1. This report(and any attachments)shall not be reproduced except in full without prior written approval of ECS. 2. The information in this report relates only to the activities performed on the report date. 3. Where appropriate,this report includes statements as to compliance with applicable project drawings and specifications for the activities performed on this report date. 4.Incomplete or non-conforming work will be recorded for future resolution. 5. The results of samples and/or specimens obtained or prepared for subsequent laboratory testing will be presented in separate reports/documents. 1100.1 Transmittal Page 1/5 A ECS Florida, LLC 7064 Davis Creek Road !MI/NMla Jacksonville, FL 32256 FIELD REPORT (904)880-0960[Phone:] (904)880-0970[Fax:] Project No. 35:29400 Report No. 1 Project 55 Sherry Drive Day& Date Thursday 09/19/2019 Location Atlantic Beach, FL Weather 70°/Cloudy Client Mathieu Builders- Dustin Brown Contractor Mathieu Builders- Dustin Brown Remarks *Travel time and mileage will be billed in accordance with the contract. Summary of Services Performed (field test data,locations,elevations&depths are estimates)&Individuals Contacted. As requested, we arrived on site to perform in-place density testing to determine the percent compaction of soils for 55 and 57 Sherry Drive. Utilizing the Nuclear Density Test Method (ASTM D6938) to check the compaction of soils; test results indicated that the compacted soils, at the areas and depths tested, met the project requirements of 95%of the maximum dry density as obtained in our laboratory using the Modified Proctor Method (ASTM D1557). These results are based upon selected locations and may not be representative of the soils in areas not tested. Should site conditions change or not be consistent with test results (e.g., pumping, rutting, standing water, etc.), ECS should be contacted immediately. Thank you for allowing ECS Florida, LLC the opportunity to provide construction materials testing services for this project. Should you have any questions and/or comments, please contact our office. By Adam D.Jackson, — Assistant Team Leader 1715 v250 12 128228 Transmittal Page 2/5 ECS Florida, LLC • 7064 Davis Creek Road Jacksonville, [ FIELD REPORT (904)880-0960[Phone:] (904)880-0970[Fax:] Project No. 35:29400 Report No. 1 Project 55 Sherry Drive Day& Date Thursday 09/19/2019 `s•0YACO �PVe " Nemer eziaj 0 A$7'E. of SE 2019 J Scarberry Senior Pdnet��k :ry; e or Project M. •.ger • By Adam D.Jackson, — Assistant Team Leader 1715 Page 2 v250 12 128228 Transmittal Page 3/5 ti ENNIS Page 1 Field Compaction Summary, ASTM D6938 Project No: 29400 Project Name:55 Sherry Drive Date:09/19/2019 Client: Mathieu Builders Test Method ASTM D6938 ECS FLORIDA, LLC Nuclear Gauge No.38 Contractor: Mathieu Builders Make Troxler Density Std 2598 Model 3430 Moisture Std 658 Technician:Adam D. Jackson Ser. No. 66267 Sample No. Description Proctor Method Uncorrected Max. Density Uncorrected Opt. MC 75871 Brown Fine Sand ASTM D 1557-12 Method C Modified 98.90 17.90 Corrected Corrected Probe Maximum Optimum Wet Dry Moisture Percent Test Test Depth Station/ Lift/ % Dry Moisture Density Density Content Comp. P/F Comments No. Lot No. Mode (in.) Location Elev Sample No. Oversize Density Content (pcf) (pcf) (%) (%) (pcf) (%) 1 DT 12 Southeast Corner House 75871 0.00 98.90 17.90 103.6 95.6 8.4 96.7 P 55 Sherry Drive Pad 2 DT 12 Northwest Corner House 75871 0.00 98.90 17.90 104.0 96.4 7.9 97.5 P 55 Sherry Drive Pad 3 DT 12 Center House 75871 0.00 98.90 17.90 103.5 95.8 8.1 96.9 P 55 Sherry Drive Pad Test Mode: DT= Direct Transmission BS = Back Scatter WO:75871 Transmittal Page 4/5 Page 1 Field Compaction Summary, ASTM D6938 ITS' Client: Mathieu Builders Project No: 29400 Project Name:55 Sherry Drive Date:09/19/2019 Test Method ASTM D6938 ECS FLORIDA, LLC Nuclear Gauge No.38 Contractor Mathieu Builders Make Troxler Density Std 2598 Model 3430 Moisture Std 658 Technician:Adam D. Jackson Ser. No. 66267 Sample No. Description Proctor Method Uncorrected Max. Density Uncorrected Opt. MC 75871 Brown Fine Sand ASTM D 1557-12 Method C Modified 98.90 17.90 Corrected Corrected Probe Maximum Optimum Wet Dry Moisture Percent Test Test Depth Station/ Lift/ % Dry Moisture Density Density Content Comp. P I F Comments No, Lot No. Mode (in.) Location Elev Sample No, Oversize Density Content (pct (Pct (%) (%) (pet) (%) 1 DT 12 Southwest Corner House 75871 0.00 98.90 17.90 102.2 95.2 7.4 96.3 P 57 Sherry Drive Pad 2 DT 12 Northeast Corner House 75871 0.00 98.90 17.90 103.4 94.7 9.2 95.8 P 57 Sherry Drive Pad 3 DT 12 Center House 75871 0.00 98.90 17.90 103.1 95.5 8.0 96.6 P 57 Sherry Drive Pad Test Mode: DT= Direct Transmission BS = Back Scatter WO:75871 Transmittal Page 5/5 ECS Florida, LLC 7064 Davis Creek Road Eire Jacksonville,FL 32256 LETTER OF TRANSMITTAL (904)880-0960[Phone:] (904)880-0970[Fax:] NIfif:00i,Z45,NA September 24, 2019 RE: 55 Sherry Drive Mathieu Builders ECS Job# 35:29400 38 W 9th St. Atlantic Beach, FL 32233 Permits: Location: 55 Sherry Dr. ATTN: Dustin Brown Atlantic Beach, FL We are enclosing: X Field Reports X For your use X As requested ENCL: Please find attached the results of the Modified Proctor(ASTM D1557)test performed on the soil sample obtained. Thank you for allowing ECS Florida, LLC the opportunity to provide construction materials testing services for this project. Should you have any questions and/or comments, please contact our office. .0OB OWF tie . '% C'CSN S E• /S, ,�'.• 'O • 5 04k/$i' Q Nemer(i�c]�};Owei , \4j 2019 J Scarberry Senior Prif i �•. F L 0 ,.• �.` r or Project Mar Disclaimer 1. This report(and any attachments)shall not be reproduced except in full without prior written approval of ECS. 2. The information in this report relates only to the activities performed on the report date. 3. Where appropriate,this report includes statements as to compliance with applicable project drawings and specifications for the activities performed on this report date. 4. Incomplete or non-conforming work will be recorded for future resolution. 5. The results of samples and/or specimens obtained or prepared for subsequent laboratory testing will be presented in separate reports/documents. 1000.3 Transmittal Page 1/2 COMPACTION TEST REPORT 100 99 117.9%.99.9 . i • 98 U 0. N C • a, V 0 97 • 96 95 15 16 17 18 19 20 21 Water content,% Test specification: ASTM D 1557-12 Method C Modified Elev/ Classification Nat. S G. LL PI % Depth USCS AASHTO Moist. p 3/4 in. No.200 0.00-0.10 SP 2.7 NP TEST RESULTS MATERIAL DESCRIPTION Maximum dry density=98.9 pcf Brown Fine Sand Optimum moisture= 17.9% Project No. 29400 Client: Mathieu Builders Remarks: Project: 55 Sherry Drive OSource of Sample: House Lot Sample Number:75871 ECS FLORIDA, LLC 7084 Davis Creek Ron.S Phone:(904)880-0880 Fax:(904)880-' Figure Tested By: KR Checked By: SB Transmittal Page 2/2 FORM BOARD/STEMWALL ELEVATION CERTIFICATE DATE PERMIT NUMBER 09/20/2019 RES19-0245 PROPERTY INFORMATION ADDRESS 55 SHERRY DR, ATLANTIC BEACH, FL 32233 LEGAL DESCRIPTION A TRACT OF LAND LYING IN THE UNPLATTED PORTION AT THE WEST END, BLOCK 2, ATLANTIC BEACH SUBDIVION A; PB 5, PG 69; RE#169756-0000 ELEVATIONS REQUIRED FINISHED FLOOR ELEVATION ON CITY APPROVED SITE PLAN & DATUM 12.5 NAVD 1988 ACTUAL ELEVATION OF FORM BOARD, STEMWALL OR GRADE STAKE & DATUM 12.73 NAVD 1988 SURVEY COMPANY CONTACT & SIGNATURE BOATWRIGHT LAND SURVEYORS, INC - LB 3672 1500 ROBERTS DRIVE, JACKSONVILLE BE' , FL 32250 PHONE: 904-241-8550 SIGNATURE OF SURVEYOR: DONN W BOATWRIGHT, PSM - LS 3295