Loading...
115 S Saratoga Cir RES19-0281 Entry Door rf % RESIDENTIAL PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH RES19-0281 ISSUED:SEMINOLE ROAD SSUED: 9/26/2019 ATLANTIC BEACH. FL 32233 EXPIRES: 3/24/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: ; VALUE OF WORK: 115 S SARATOGA CIR RESIDENTIAL ALTERATION ENTRY DOOR $1047.00 RESIDENTIAL TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 171768 0000 ATLANTIC BEACH VILLA# 02 COMPANY: ADDRESS: CITY: STATE: ZIP: LOWES HOME CENTERS 4948 TELSON PL ORLANDO FL 32812 INC OWNER: ADDRESS: CITY: STATE: ZIP: CLEMENT LARRY E 551 CAMELIA TERRACE DR NEPTUNE BEACH FL 32266 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. u,. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $60.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $30.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 Issued Date:9/26/2019 1 of 2 i„.:Sy.-- City of Atlantic Beach APPLICATION NUMBER # ' :,, Building Department (To be assigned by the Building Department.) a- 800 Seminole Road (/� 7��\ 1 ri :1 R ES1 A ^ �t Atlantic Beach, Florida 32233-5445 '\Jv v Phone(904)247-5826 - Fax(904)247-5845 "?o;t►l)'” E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l l 5 S RA(('pC,R LDepartment review required Ye No uilding Applicant: L O LoE� (Y1 E C��3 (� Planning&Zoning Tree Administrator Project: �P�TfZL( re___ Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: F pproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDIN PLANNING &ZONING Reviewed by: Date: 9 /'/9 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application OFFICE COPY ^ Updated 10/9/IS .....r, City of Atlantic Beach Building Department J **ALL INFORMATION ` t,J, ! 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@caab.us IS REQUIRED. Job Address: /1 S~ .5 it - i,. ./-zziz` /1'/1 l..../Permit Number: RC-SI - �C) li legal Description 31-13 38-2S-29E ATLANTIC BEACH VILLA UNIT 2 LOT 2 BLK 3 REIT 171768-0000 Valuation of Work(Replacement Cost)$ 1047.00 Heated/Cooled SF Non,-.Hem --t-I ---.) _--•- --_-_•-_ --•-- • Class of Work: ONew UAddition ❑Alteration °Repair ❑Move ODemo DPool i ' '- --": '" '" -" • Use of existing/proposedf_ structure(s): OComrnercial residential • If an existing structure,is a fire sprinkler system installed?: °Yes ONoSEP 1 6 2019 • Will tree(s)be removed in association with proposed project? [(Yes(must submit separate Tree Removal Permit) Ci o L.__ I Describe in detail the type of work to be performed: REPLACING 1 DOOR SIZE FOR SIZE i,e p J ter ,f: ' i ri /k. t Jr,-rw V l t z Florida Product Approval 11 16468.1 for multiple products use product approval form Property Owner Information Name ..`TG` C'"0h (1 I e- )1 I c r 1 ) Address 11 7 :534./- Vit.;:ill't. ' /21 f . 5 • City i' I%i l I-I I e._. /-! Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv... Product Approval Method Method 1 Option D OFFICE COPY Date Submitted 04/22/2019 Date Validated 04/22/2019 Date Pending FBC Approval 04/29/2019 Date Approved 06/18/2019 Summary of Products FL# Model,Number or Name Description 16468.1 A Design Pro /Smooth Pro / Single (X) Opaque Door 3-0 x 6-8 and 3-0 x 8-0 Inswing . V Studio Fiberglass and Outswing Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16468 R13 II A010861A X.OPO SS 2019-04-22.Ddf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: FL16468 R13 AE PER4655.1 SS 2017-11-17.pdf Created by Independent Third Party: Yes 16468.2 B Design Pro /Smooth Pro Single (X) Glazed Door 3-0 x 6-8 and 3-0 x 8-0 Inswing Fiberglass and Outswing Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16468 R13 II A010862B X, GLZ SS 2019-04-22.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: FL16468 R13 AE PER4430.2 X GLZ SS 2019-04-22.pdf Created by Independent Third Party: Yes 16468.3 C Design Pro/Smooth Pro/ Double (XX) Opaque Door 6-0 x 6-8 and 6-0 x 8-0 Studio Fiberglass Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16468 R13 II A010863A X. OPO SS 2019-04-22.Ddf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: FL16468 R13 AE PER4656.1 SS 2017-11-17.pdf Created by Independent Third Party: Yes 16468.4 D Design Pro /Smooth Pro Double (XX) Glazed Door 6-0 x 6-8 and 6-0 x 8-0 Inswing Fiberglass and Outswing Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16468_R13_II_A010864A XX, GLZ SS 2019-04-22.pdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: FL16468 R13 AE PER4432.2 XX GLZ SS 2019-04-22.pdf Created by Independent Third Party: Yes 16468.5 E Design Pro/ Smooth Pro / Single with sidelite(s) (X,O/O,X/O,X,O) Opaque Door 9-0 Studio Fiberglass x 6-8 and 9-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16468 R13 II A010865A XOX, OX,OPO SS Approved for use outside HVHZ: Yes 2019-04-22.Ddf Impact Resistant: No Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16468 R13 AE PER4657.2 OXO OPO SS 2019-04-22.odf Created by Independent Third Party: Yes 16468.6 F Design Pro /Smooth Pro Single with sidelite(s) (X,O/O,X/ O,X,O) Glazed Door 9-0 Fiberglass x 6-8 and 9-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16468 R13 II A010866B XOX, OX, GLZ SS Approved for use outside HVHZ: Yes 2019-04-22.pdf Impact Resistant: No Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16468 R13 AE PER4434.2 OXO GLZ SS 2019-04-22.pdf Created by Independent Third Party: Yes 16468.7 G Design Pro /Smooth Pro / Double with sidelite(s) (XX,O/O,XX/O,XX,O) Opaque Door Studio Fiberglass 12-0 x 6-8 and 12-0 x 8-0 Inswing and Outswing 2 of 3 7/15/2019, 7:46 AM DESIGN PRO / SMOO -�'FH PRO /STUDIO NON-110F'ACT FOR USE IN THE HIGH VELOCITY,HURRICANEZONE (HVHZ) GFNIFRAI NIhTPc- 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EWILUATED ACCORDING TO THE FOLLOWING: • TAS 202-94 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY OR 2X FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 4. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED CIN THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 5. 6 -PANEL DOOR SHOWN FOR ILLUSTRATION PURPOSES. P,DDITIONAL PANEL CONFIGURATIONS AND FLUSH DOORS ARE QUALIFIED. 6. NOTE: AFCO H-497 SILL MEETS WATER INFILTRATION AT WATER TEST PRESSURE (WTP) OF 9.75 PSF. REMAINING SILLS NOT RATED FOR WATER INFILTRATION. IF AUTHORITY HAVING JURISDICTION REQUIRES THAT PRODUCT MEETS THIS REQUIREMENT, PRODUCT SHALL BE USED WHEN INSTALLED AT LOCATION PROTECTED BY OVERHANG SUCH THAT OVERHANG (OH) RATIO = OH LENGTH _ OH HEIGHT IS >_ 1.0 TABLE OF CONTENTS . WIDTH �v SHEET REVISION WIDTH SHEET DESCRIPTION 1 A TYPICAL ELEVATIONS, DESIGN PRESSURES, AND GENERAL NOTES 2 A TYPICAL ANCHOR LAYOUTS AND NOTES 3 B OPTIONAL 2X BUCK ANCHORING DETAILS AND QUALIFIED SKIN PATTERNS 4 A NON -IMPACT VERTICAL ASSEMBLIES 5 A HORIZONTAL ASSEMBLIES, GLAZING DETAIL 6 A 50 WOOD SUBSTRATES 7 A CDNCRETE SUBSTRATES 8 A COMPONENTS & BILL OF MATERIALS 37 1/2" MAX.: O.A. WIDTH iii=1 IMI x 00 QD . WIDTH �v DESIGN PRESSURE (PSF) MISSILE IMPACT RATING WIDTH z � I OUTSWING POS. 0 POS. NEG. X 3'-0" 6'-8" v 65 .1 65 NON -IMPACT X POoaQE)OO 87-0" 50* 50 • 50 NON -IMPACT o , ACTIVE / LU LnLn O < Lo O z o [I � a Wo < / W J W I I Q TYP. ELEVATION 1 1 6'-8" DOOR HEIGHT V OFFICE COPY 37 1/2" MAX. v� . WIDTH �v DESIGN PRESSURE (PSF) MISSILE IMPACT RATING WIDTH I I INSWING OUTSWING POS. 0 POS. NEG. X 3'-0" 6'-8" v 65 .1 65 NON -IMPACT X T-0" 87-0" 50* 50 • 50 NON -IMPACT o , o z Q o 3 4 5 6 7 8 9 4 4 4 4 4 4 4 r2_-� TYP. ELEVATION 2 1 8'-0" DOOR HEIGHT NOTE: DOORS SHOWN ABOVE MAY BE LEFT OR RIGHT HAND OPERATING DOORS. REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS REVIEWED BY: - DATE: CONFIGURATION MAX. OVERALL NOMINAL SIZE DESIGN PRESSURE (PSF) MISSILE IMPACT RATING WIDTH HEIGHT INSWING OUTSWING POS. NEG. POS. NEG. X 3'-0" 6'-8" 65* 65 65* 65 NON -IMPACT X T-0" 87-0" 50* 50 50* 50 NON -IMPACT JCC UCIVCL(HL INU I t b, )Ht:t 1 1, FUK VVAILK INFILI KAI ]ON APPROVED SILLS. PREPARED RV /(k BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX:(954)744.4738 WEB: www.buildi"gd,ops.co 0 Q Ln W o > o' o '0'°mNo m�N LU = Q oaCL Q=v�, H (� W < maQ O� m Q O W o z Q o CICx Q_ � z o z � a Wo LU a W J W Vs � a_ N o 10 z H LU J REMARKS BY DATE Add ADA sill, Multi -Point Lock GL 06/19/14 AND SHALL NOT BE REPRODUCED IN WHOLE OR PART WITHOUT WRITTEN CONSENT OF BUILDING DROPS, INC. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. ®0 S A OF •' igitally signed by Hermes F Norero eason: I am approving this document ate: 2019.04.22 20:23:56 -04'00' DATE: 02.05.14 DWG. Y: CHK. BY: GL�TJM SS/MSS SCALE: NTS DWG. #: A010861A SHEET: OF 8 1 INSTALLATION NOTES: I PREPARED a 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH AN(:HOR LOCATION SHOWN. 8'0" DOORS ANCHOR TYPE ANCHOR OFFICE COPY MIN. MIIN. 12� 2. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SIZE EMBEDMENT DISTANCE MAX. O.C. MAX. O.C. SHIM STACK TO BE 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BEA BUILDING DROPS, INC. NON-COMPRESSIBLE COMPOSITE OR BETTER. JAMBS JAMBS WOOD SCREW #10 2X WOOD BUCK 3/4" 17-1/2" 17-1/4" 398 E. DANIA BEACH BLVD., STE. 338 3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE Wy4lL FINISHES, INCLUDING BUT NOT LIMITED TO ITW TAPCON 3/16" CONCRETE/CMU DANIA BEACH, FL 33004 PH: (954)399-8479 STUCCO, FOAM, BRICK VENEER, AND SIDING. 17-1/2" 17-1/4" ELCO ULTRACON 1/4" CONCRETE/CMU 1-3/8" - CONIC. AX:(95www.b)744.4738 FAX: (954)744.4738 1" 17-1/2" 17-1/4" 1-1/4" - CMU WEB: m 4. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL ITW TAPCON 3/16" CONCRETE/CMU 1-1/4" 1" 10" 14-3/8" OR HAVE A CORROSION RESISTANT COATING, AND SHALL HE INSTALLED IN ACCORDANCE WITH ANCHOR o MANUFACTURER'S INSTALLATION INSTRUCTIONS. ^ � 5. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR 37 1/2" MAX. O � � Fpm L JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE CIF BLOCK OR EDGE OF MORTAR JOINT INTO FACE 3" TYP O.A. WIDTH O C) o Ln00u, 00 00 SHELL OF BLOCK. C2 C2 3" TYP. Z a ti aQ a F 6. FOR 2X STUD CONSTRUCTION, ANCHORING OF THESE PRODUCTS SHALL BE THE SAME AS FOR 2X BUCK OO Z m < Q CONCRETE/MASONRY CONSTRUCTION. F_ Q az 1 m Q 7. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: O Z C] A. WOOD -MINIMUM SPECIFIC GRAVITY OF 0.55. � >_ a F-10 r ,o B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. - - _ � Q C. GROUT FILLED CMU- UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH DO CD 00 w w m w - a OF 2000 PSI AND GROUT CONFORMS TO ASTM C 476, MINIMUM GROUT COMPRESSIVE STRENGTH OF 2000 Q CO i.� O 90 PSL m , c cc p = 3 D. HOLLOW BLOCK CMU - UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH z < 0 O OF 2000 PSI. p Z z N q z w v z Q Q 7 8. SEE SHEETS 6 AND 7 FOR MORE DETAILS OF THE INSTALLATION REQUIREMENTS, INCLUDING ANCHOR O � w -I LOCATIONS, EDGE DISTANCES, EMBEDMENTS, AND SHIM SPACING. 0 z Q Lu vwi FF_ 9. OPTIONALLY, ANCHORS CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMB AS LONG AS MINIMUM REMARKS BY DATE EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED, I Add ADA sill, Multi -Point Lock I GL 06/19/1 ANCHOR TABLE 6'8" DOORS 8'0" DOORS ANCHOR TYPE ANCHOR SUBSTRATE MIN. MIIN. EDGE SIZE EMBEDMENT DISTANCE MAX. O.C. MAX. O.C. SPACING AT SPACING AT JAMBS JAMBS WOOD SCREW #10 2X WOOD BUCK 3/4" 17-1/2" 17-1/4" OR FRAMING ITW TAPCON 3/16" CONCRETE/CMU 1-1/4" 2-1/2" 17-1/2" 17-1/4" ELCO ULTRACON 1/4" CONCRETE/CMU 1-3/8" - CONIC. 1" 17-1/2" 17-1/4" 1-1/4" - CMU ITW TAPCON 3/16" CONCRETE/CMU 1-1/4" 1" 10" 14-3/8" B2 2- #9 X 2 1/2" PFH PFH SCREWS DETAIL B2 TYP. HOPPE 1- BOTTOM SHOOT MULTI -POINT SHOOT BOLT BOLT PLATE PLATE LOCATION HOPPE #2098911 SILL SECTION VIEW 7 / INSWING SHOWN OUTSWING SIMILAR SEE DETAIL B2 2- #9 X 2 1/2" PFH SCREWS DETAIL D2 TYP. HOPPE MULTI -POINT SHOOT BOLT PLATE LOCATION (RH PLATE SHOWN) i D2,, [C-) HEAD SECTION VIEW 2 INSWING SHOWN DUTSWING SIMILAR SEE DETAIL D2 22 TYP. ANCHOR LAYOUT 2 6-8" & 8'-0" DOOR HEIGHT NOTE: NO ANCHORS REQUIRED AT THE SILL FOR SINGLE DOORS (X) JON. NOTE: INACTIVE AND ACTIVE DOOR PANEL ORIENTATION IS INTERCHANGEABLE. AND SHALL NOT BE REPRODUCED IN WHOLEORPART WITHOUT WRITTEN CONSENT OF BUILDING DROPS, INC. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND DATE: 02.05.14 DWG. BY: CHK. BY: GL/TJM I SS/MSS SCALE: NTS DWG. #: A010861A SHEET: OF8 0