1506 Jordan St DWAY19-0033 Asphalt rt�"'�\�`% DRIVEWAY PERMIT PERMIT NUMBER
r 7 4 .Sd
qr, ' CITY OF ATLANTIC BEACH DWAY19-0033
y ISSUED: 9/30/2019
800 SEMINOLE ROAD
`moo;:»r ATLANTIC BEACH. FL 32233 EXPIRES: 3/28/2020
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
1506 JORDAN ST DRIVEWAY SINGLE OR TWO ASPHALT DRIVEWAY $2500.00
FAMILY DRIVEWAY
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
172295 0000 ED SMITH S/D
COMPANY: ADDRESS: CITY: STATE: ZIP:
A & B Asphalt Repair Inc. 700-39 E. Union St. Jacksonville FL 32206
OWNER: ADDRESS: i CITY: STATE: ZIP:
Duncliff Trading Company 4240 FULTON AVE #112 Atlantic Beach FI 32233
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS DRIVEWAY APRON INFORMATIONAL
Notes:
All concrete driveway aprons must be 5 inches thick,4000 psi,with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh
are not allowed in the right-of-way.
2 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(904-247
-5814)to request an Erosion and Sediment Control Inspection prior to start of construction.
Issued Date: 9/30/2019 1 of 2
ite ` 0.
'''s' DRIVEWAY PERMIT PERMIT NUMBER
.` CITY OF ATLANTIC BEACH DWAY19-0033
ur ISSUED: 9/30/2019
800 SEMINOLE ROAD
°s:i9r ATLANTIC BEACH, FL 32233 EXPIRES: 3/28/2020
3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list(Advanced Disposal,Realm Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters,
Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way.
5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration,including sod,is required.
6 PUBLIC WORKS RUNOFF INFORMATIONAL •
Notes:
All runoff must remain on-site. Cannot raise lot elevation.
7 PUBLIC WORKS MAXIMUM DRIVEWAY INFORMATIONAL
Notes:
Maximum driveway width within the City right-of-way is 20 feet.
8 PUBLIC WORKS DECKING REMOVED INFORMATIONAL
Notes:
All old decking debris must be removed from job site by Contractor.
9 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
10 PUBLIC WORKS ADDITIONAL COMMENTS PUBLIC WORKS INFORMATIONAL
Notes:
Right-of-way must be repaired and raked out with sod by Contractor.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00
ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00
TOTAL: $125.00
Issued Date:9/30/2019 2 of 2
olA r, City of Atlantic Beach rAPPLICATION NUMBER
ter} ? Building Department (To be assigned by the Building Department.)
_ - 800 Seminole Road II� 10 -0033 0 0 3 3
y �,- Atlantic Beach, Florida 32233-5445 ��1", l/
Phone(904)247-5826• Fax(904)247-5845
�tni �� E-mail: building-dept@coab.us Date routed: gitit9
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: I 5000 JCS g..OQ)N `t" Department review required Yes No
kPNAL-T
Buildin
Applicant: fanning &Zonin
Tree Administrator
Project: : R I v i-G O Ay Public Work;----)r Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: I 'Approved. enied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING
Reviewed by: Date. (c — (q
TREE ADMIN. Second Review: A roved as revised.
❑ pp ['Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:_.
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. I INot applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
i=.: r City of Atlantic Beach ` APPLICATION NUMBER
jS ��c6 Building Departmentiiir"c
(To be assigned by the Building Department.)
800 Seminole Road UG 15 2019 i i tfuPk(-(l ci -0033
Atlantic Beach,7Florida 32233 5445
—013 •r E-mail: 5845
on (b0u4d n4-de t6 coab.us• 4)gyp`— Date routed: 8 1 ( i i 9
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 'SOG7 JO zi)oro T Department review required Yes No
Building
Applicant: 1- a i \s P HA L7 Tlanning &Zonin
Tree Administrator
Project: -: l . V EGO ky Public Work
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. 716enied. ['Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING / - (
Reviewed `,y�.—' ate: 0,7ff
TREE ADMIN. Second Review: VApproved as revised. ❑Denied. ElNot applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES /
PUBLIC SAFETY Reviewed bpv` Date: ?--/71
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
Building Permit Application Updated 10/9/18
i. " City of Atlantic Beach Building Department "`ALL INFORMATION
' .
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
_ 5'
Phone: (904) 247-5826 Email: Building-Dept@coab.us ( REQ /-,
Job Address: I re' J reilho S frecf'- Permit Number: 0 wall/5 'qufRED.L -0063
Legal DescriptionNip•5 /7-}(•a7E ■•4'7 loll. 13 lima rB/tC _RE# /baaQS-eo i
Valuation of Work(Replacement Cost)$ .; rb 0 -T _Heated/Cooled SF _Non-Heated/Cooled, —
• Class of Work: ❑New ❑Addition OAlteration i1Ftepair OMove [JDemo ❑Pool OWindow/Door
• Use of existing/proposed structure(s): IlCommercial i Residential
• If an existing structure,is a fire sprinkler system installed?: OYes 1t7A1Q
• Wii tree(s)he re-novec in association with proposed protect? Yesimust s:hrnit separate free Rerinvai Permit) *MS
Describe in detail the type of work to be performed: /'c
0,1)cc A•dq, "fir
Florida Product Approval ft _____ __ _ __for multiple products use product approval form
•
Property Owner Information
�{,� C Anrr ss_ L��D /'s►/t#ot /41r� *9i -
Name_�nt,l:� T��r 1 .- dPhone
City C,145, / stare C/ • z p �j/e y S/
E-Mail
Owner or Agent(If Agent,Power of Attorney or Agency Letter Required)_
Contractor Information Q
Name of Company 1440PA /t___jey t//". Qualifying Agent t• /411j 4,4/-
Address WO
f/-AddressWO- f re_1/&*)of s l.-- _ . City hCfiluM k/c _State 7 41 A POA _
Office Phone foe-_- rV 1 7J _Job Site Contact Number O' 3 f4 S
State Certification/Registration St_"- E-Mail
Architect Name&Phone t1
Engineer's Name&Phone ti__
Workers Compensation Insurer ALTeSto fl_eitipehill f Ve • IR Exempt o Expiration Date p t)e�Z119
Application is hereby made to obtain a permit to do the work afrd installations as indicated.I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDE tIR AN ATTORNEY BEFORE
RECORDING Y U NOT cE OF COMMENCEMENT. . /. /-
t-------- ---
(Signature of 0 ner or Agent) (Signature of Contractor)
�Zn �0day
Slued and swot tgo(sr affirmed)before me this day ofVoid swo � ffir ,. e •r of
J•� 1 4-U ' b A( 1- f J�� J/11L_±, r I��. Or
j ftwi Zr J ,1TOhA i I i' i r in*
(Signature of Notary) (Signature of No;d� .y '',
aOTARy t
C.)
P rsonall Known OR My Comm.Expires CP-1
( }Personally KnOLOOR " • ..i, 1
L
O yid f June 28.2022
( oduced Idantii.c4.A11 / ,.,•. ( roduced entr icationFL typo of Identificatio- -
d' PuBL.IG
T$'
f ',
�,.YjL:4\-i%jJ�
(f"
CITY OF ATLANTIC BEACH
`�� Department of Public Works
v
`� -.,/s-) 1200 Sandpiper Lane
�'� Atlantic Beach, FL 32233
A:-/-JSSIr (904) 247-5834
PUBLIC WORKS PLAN REVIEW COMMENTS
Date: 8/16/19 Applicant: A & B Asphalt Repair
Permit#'s: DWAY19-0029 - 0036 Email: dave@abasphaltrepair.com
Review Status: DENIED Property Owner: Duncliff Trading Company
Site Address: Jordan Street: Email: Not Provided
1501, 1502, 1503, 1504, 1506, 1507, 1509, 1512
THIS PLAN REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS
Correction Items must be submitted to the Building Department at 800 Seminole Road.
Submittals that respond to only one or a few correction items will not be accepted.
Revisions may not be submitted until ALL departments have completed their respective reviews.
Revisions must be submitted to the Building Department and must respond to EACH department review.
PUBLIC WORKS CORRECTION ITEMS: VISED
• Provide individual plans for each address that can be scaled for i e rea.
• Section 24-66(b) of the Land Development Regulations requires on-site storage for increased
run-off if adding 250 SF or more impervious surface. Provide Delta volume calculations and
on-site retention required per Section 24-66(b).
• Provide a detailed plan of water retention area and how water runoff gets to water retention
areas and then to street.
APPROVED PPRO■ ED
PUBLIC WORKS CONDITIONS OF APPROVAL: �i���✓
(The following comments will be printed on your permit as Conditions of Approval) �,
• All concrete driveway aprons must be 5" thick, 4000 psi, with fibermesh from edge of pavement
to the property line. Reinforcing rods or mesh are not allowed in the right-of-way.
• Full erosion control measures must be installed and approved prior to beginning any earth
disturbing activities. Contact the Inspection Line (904) 247-5814 to request an Erosion and
Sediment Control Inspection prior to start of construction.
• All runoff must remain on-site during construction.
• Roll off container company must be on City approved list (Advanced Disposal, Realco
Recycling, Shapells, Inc., Republic Services, Donovan Dumpsters, Phillips Containers,
JDog/Dennis Junk Removal, All American Roll Off, WCA Waste Corporation). Container
cannot be placed on City right-of-way.
• Full right-of-way restoration, including sod, is required.
• All runoff must remain on-site. Cannot raise lot elevation.
• Maximum driveway width within the City right-of-way is 20'.
• All old decking debris must be removed from job site by Contractor.
• Any damage done to infrastructure must be repaired by Contractor.
Scott Williams, Public Works Director swilliams@coab.us/904-247-5834
Page 1 of 2
O:\Public Works\ADMIN\PLAN REVIEW COMMENTS\DWAY19-0029-0036(A&B Asphalt Repair).docx
Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a
revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the
sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the
cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block
for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit
pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked
"VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL
ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR
REVIEW.
Page 2 of 2
0:\Public Works\ADMIN\PLAN REVIEW COMMENTS\DWAY19-0029-0036(A&B Asphalt Repair).docx
MAP SHOWING BOUNDARY SURVEY OF:
PARCEL IDENTIFICATION NO./732950000(1506 JORDAN STREET) N
A PORTION OF LOT 13.BLOCK I.ED SMITH SUBDIVISION.AS RECORDED IN PLAT BOOK 26.PAGE 50 OF
THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY. FLORIDA. MID PORTION BEING MORE
PARTICULARLY DESCRIBED AS FOLLOWS:
FOR A POINT OF REFERENCE,COMMENCE AT THE SOUTHEAST CORNER OF LOT Id.BLOCK.I.ED SMITH
SUBDIVISION,THENCE RUN NORTH 0 DEGREES 15 MINUTES WEST ALONG THE EAST LINE OF LOTS 14
AND 13 A DISTANCE OF 87.65 FEET TO THE POINT OF BEGINNING,THENCE CONTINUE NORTH 0
DEGREES 15 MINUTES WEST SAID EAST LINE OF SAID LOT 13,A DISTANCE 0F2066 FEET:THENCE
RUN SOUTH 89 DEGREES 36 MINUTES WEST PARALLEL TO THE SOUTH LINE OF MID LOT 13.A
DISTANCE OF 100.0 FEET TO THE WEST LINE OF SAID LOT 13.THENCE RUN SOUTH 0 DEGREES 15
MINUTES EAST ALONG SAID WEST LINE A DISTANCE OF 20.66 FEET:THENCE RUN NORTH 89 DEGREES ...--,.
36 MINUTES EAST PARALLEL TO THE SOUTH LINE OF SAIDLOT 13,A DISTANCE OF 100.00 FEET TO TN.
POINT OF BEGINNING.
.....A.--..___,,_,„__,,...____R---5-11 • 100.00'(PLAT)
T 97/7//E66////7 V
sk/aj //• •, RMRrav0Ptbn
''''''''''''-',3
R.WBN 0NI0Q % TWD STORY • YY bN
�ti iWAHON / L+ PNO o LOT].5.000] % Abbrev,CP6r POINT bn
�_,,// TOWNHWE ,KIWI 5,0 PC POINT 0.030'T:1:
Cr
6.....\\1,..„...mY.v6vu�r'� /1502 GRAVEL CURVATI.P♦f
PT P NT s
GRAVEL AVN1[
/ i PDC PDINT O!
- �?---- CLRVE
- _/0 \YM'N'!10505'IRB\O) �V RECORDS
'_ ME UNDERSIGNED HAS LOCATED �1PIm S1°9� / TWO STORY 'O' o-D1 A'WOOD FENCE V RD
POSSIBLE APPARENT USE OF ADJACENT LANDS. FRAMED ..F r r\ C s 5/0 RIGHT, OAT
UNE
NO VERIFICATION OF FIREWALL OR WALL MOUNTED TOMNHORE 1 r. RpV RIGHT pt'VAY
UTLITES WERE LOCATED TO DETERMINE E 4 ! •
/1504 . . GRAVEL co .• ps µ6 F��/ 2627, k BN 80tlX
�. OWNERSHIP iai TEE Ak'�fl BBB 1 (OObF-`- ® i■ J( - CJs-L II PG PAGE
_� TV V 6 ® [}SITS • v�// TWO STCRY y •sIa¢ T.66 P09 PONT OF
INNING
* `pI\�6ypyW� j TWO STORY •, 3 �s�® _ / TOWNHOIE iJ YL i COv'D $COOVVERUEDDE
G \/N FRAMED F /150i STOtAOL APPROX APPRO%(NATE
Ij �"TOWNHOIE GRAVEL 3 T GRAVEL % T
_M'�M-LL\7C\/"/ /1506 w GRAVEL Op ' S 65. BLDG BUILDING
;� �P1 / I /S0/� A Ij- CONC CONCRETE
GRAVEL ---SII•-'--�5 --ILZr--� R RADIUS
��E$ \� GRAVEL •MN51('i •anew
i sOal m.{_� // mar arm-. 1..) -__ _. - Ya SEC SECTION
TIE 0 ^^^}}}777�"� CAAVn_ PONT OF GRAKL ( TWO STORY ,.y1O1E ET ELECTRIC
FRAMED TRANSFORMER
4,44,1.--.__
`% TWO STORY % BEONNING P TOMNHOME AC LLppNHppAIR
_� FRAMED F / RUT LOW O LOT(WOO] Y Mn /(SOS ,', �` CN CHDRDI LIENTDTPH
// TOMN506 E GRAVEL 1 [D NT;ND • • wro C
\\•. k2V f T -lu--- / OLH ARC
GRAVEL 41® '• : W5 , TWO STORY "AVERT"Two-n47,-.....,,
.' TWO STORY ""'•�:.f11f•••����aaaa RtAMEO 1/ R� 1� TR TRACT
�` •
.iW n TOWNHOME ■ N PT POINTOF
/ FRAMED % r_^ r S H B 1505 PB IlLAT BOIX
\j��/// TOWNHONE / E
TR sk�J"V 8 510 • N, ' • w
A OM.PART,r -P *I. '
IP IRON PIPE
YRpO IID / .P BM•i\TIr1M tM.0r MID).•• • • = F RL' %• • 1 e SECONDS
1
-.--2
_ !____ %/��1 .k`. k . W.y P Ur ' •i.1 € A/C CONDITIONER
LOT 1,BLOCK 1 -;--'Mf / !� Iq r trips 1 GRAVEL •i r I TWO STORY / •, P•p A NTS NCO TO SCALE
EO TAIL ' .n- TOO STORY Z. ` 666 F FRAMED 0 CENTRAL ANGLE
FRAMED • 1 a 0 \ J •1 I d / TOWN=IE o
0 F.RID fwB� i0WN5WE "•} '• C9 i g GRAVEL 5 1507 Af '' ,•sTA1E .4
N.• NAPPTw€V`x / / o i
B~o GRAVEL 20 SL k Nv y
g n Y.Y. .TA {�
{ t
,t c�%/////...w/il f n L�p��/ R.,.
_�YfLt 0d GRAVEL TAO STONY .•.MSIOn - 05100 Twr
B ? . FRAMED C0CRETE
RaP 10�A0, a TOWNHOME
V WORK _ /1509 • srvf /I
T SLY LRE OF LOT 14,' w ,'�/ I C u COHERED S
`- EO SRAM S BLOG(1 Y 1 Ill 's COVERED TRATE ')�f
•
o roomy V TV 0 pr03N 8100-m.�)
P 1 s'LY LINE OF LOT(,BLOCK I ' rt ram, •TP W .'1.
OTS 'j PONT OF BEGINNING(I1512) y „N• - .3.48,0.11.41
lam OS•03'00'V 100.39•(DEER)
. r •• T • ' F " n •
SOUTHEAST CORNER OF ''--1-^.-46'A�.i.a11011LI
LOT IS.BLOCK 1,ED 90TH SAD .i
SURVEYOR NOTES PR 26 PG 50 n .,r...1
THIS IS A BOUNDARY SURVEY DINNER
TOAD SPM'W/W PER PLAT)
NO UNOERGRWNO UTILITIES T LOCATED. (SCALED GB) BAn1��BANKS ITPSRWY SEAMY TO.
I NO UnurIES SERMCNO BUILONG ATTACHED N EXTERNA WALLS 4-4.‘-.-
WERE nor LOCATED CONSULTING,INC. HOUSE R`AL,
• M
NO DETERNATT R OF OMRERSNP OF PARTY ROLL OR INVESTIGATION f .11111•1 o WEST 9114 aTRBeuTUNnc BEu TI.Fl TOA THIS SURVEY MEETS THE STANDARDS OF PRACTICE AS SET FORTH
A
KFIREWALL I I'- ' I F -•/ BF AEICULTURBOND CFSURVEYORS AND SMAPPERS UNDER THE SECTION 5 MEMOIR LOCATION OILY O PPEMIlEl. M ,,'1� / ISR1}.53.R PA%ObN},.x62]R6 OF 027 FLORIDANRE ANO CONSUMER SERVICES.PURSUANT TO SECTION
NO au..PLANS MERE AVASAAE. „ '/// A GROSPATIALCOMPA,v 4)1.027 FLOSTATUTES AND CHAPTER 51.07050
FLORIDA ADWNISTRARVE CODE
6 BEARINGS AND DISTARCEs METE THEN FRW THE DEED PROVIDED r L O I.I P A 1,S.I t.9 8 U S R D A ET�Y r O M_S)2BANNSANDBANICSEONSULTLNG.COM
BASED GN THE ED SHIN PLAT PB 26 PAGE 50. PLANS ARE I NCH-33 FEET IF PRINTED ON IB'12.4914.44""I
PUNS ARE I INCH 33 FEET IF PRINTED W it X IT PAPER
GENERAL NOTES: P 4
NOTES
NO uNDERCAWND unu TES OR STRUCTURES LOCATED. 1Ry ypyET REOISTE U `O .+ '1 0
2 NO ONT.LOCATED E%CDT AS MAY BE!NOTA.HEREON. NIS IS
] NO ATI.,WAS MADE TO LOCATE JURISOCTONAL REMAND USES
NOR TD NOTIFY ME PROPER ACENOES. FLOW ZONE TOT AS BEST ASCERTAINED PAW FLOOD PANEL NO DARYL S BANKS CERTIFICATE 11606.1 No 8063
ABSTRACT OF TILE WAS NOT FURNISHED TO THE UNDERSIGNED. 2031C0106.114 DATED 11.2.2016 A
5 YERTCAL DATUM BASED ON ME NBA O O 1904 YI STATE OF
BEARNO DANN BASED W TME Ely RIO UTE OF JORDAN ST BONG NOTVW. DATE AUGUSTS,2012
UNITED USE AND DISCLAIMER THERE MAY 8E ADDITWAL RESIRICTCNS MAT APPLY BUT A1E NOT SHORN W (/.�•.,('�DR IO_MKQ.
By ME USE OF MI5 SURVEY,YOU AGREE TO BE 6OINO BY THE TERMS BATTEN ON MIS MIB SARNEY SLIT MAY BE FOUND IN ROE PUBLIC RECONS W FACTURES O 04,R SCALE W INCH•20 FEET SAA-'-
SURVEY.
1TI15 GC.,
JOB NO 17241
THIS SJRVEY II INTENDED FOR SOLE USE OF THE PARTES CERTFIED HEREON. THISURVE
SOW,DOES NOT DDEM..OMNERSHP
1 L AsSO.MIs SURVEY ORAMNG OR ANY INTEREST CR
NO
wITEAEW WMWr THE PROP WTOTTEN CONSENT OF ME UNDOISCPED. LICENSE BUSINESS NUMBER 7820
I ANY REPRODUCTOH O MI5 SUAVE.IS PROHIBITED.
THIS SURVEY WAS ELECTRONICALLY CERTIFIED BY DARYL S.BANNS.PSM 6081.AS TIMES,11,50 ON BORDER
0/9/2019 4:55A7 PM
( „ REVOCABLE ENCROACHMENT PERMIT
,r
-- ---;
REVOCABLE ENCROACHMENT PERMIT by the City of Atlantic Beach, Florida,a municipal corporation
organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and
___
-Z21 17-44. �—1 yt �M ___ of Atlantic Beach, Florida, hereinafter
referred to as'99"USER".
WITNESSETH:
That the CiTY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the
property for the purpose as described in the City of Atlantic Beach.
This work is generally described as /9ieYe•J47 Jeceiffea A•'�-
Any facility maintained, repaired, erected, and/or installed in the exert se of the privilege granted remains subject to
relocation or removal on thirty (30)days' notice by CITY to USER, said notice to USER shall be given by certified mail,
return receipt requested, to the following address / re** Trd.M 5-(Feet
• In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter
upon the above described property of the CITY, the USER shall replace at the USER's sole expense, any and all
material necessarily displaced during the action of maintaining, repairing, operating. replacing or adding to of the
utilities and facilities of the CITY or franchise utility provider.
• The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land
Development Code and all otlier land use and code requirements of the CiTY,including City Code Section 19-7(h)
which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must
be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks."
• The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from
the City of Atlantic Beach Public Works Department, for said change within 30 days after the day of completion.
• This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns.
• USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or
specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and
other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by
the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby
assumed by the USER.
QM ' . (517‘--- . Date 7/1:1")61
Property Owner/Agent(signed in presence of Notary Public)
CAliforNo( to Ah jeieS
STATE OF P1-.411:1T-TX.COUNTY OF 44.14/AL nA
The foregoing instrument was acknowledged this 4, day of J ,2014
by tt' '-'j SS _ _ ,who personally appeared before me and
(printed name of Signer)
acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it.
11""I itlk____VIA'AL4)
Signature of Notary Public,State of-Ftorttia C•,(;C-+r.1;1
Approved /Public Works Department:
Personally Known _
Produced Identification(Type) a, CI 4L
Scott WI h'ams,Public or s'Director
j`" r 1i:14i'tl' c`.3';A:kr .t1
- 4 COMM. #21 ,:•223 z ��/�f�/
rt_-�td .t (rotary Public Calrt,:rn:e 7
•
- \a i. Los Angeles t o• .ty
"'-�y'M'=� P.',COMM i Xaire5 M,,, '2 .0''l pp
MAP SHOWING BOUNDARY SURVEY OF:
A PORTION OF LOT 13, BLOCK 1, ED SMITH SUBDIVISION, AS RECORI)ED IN PLAT BOOK 26, PAGE 50 OF
THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA, SAID PORTION BEING MORE
PARTICULARLY DESCRIBED AS FOLLOWS:
FOR A POINT OF REFERENCE, COMMENCE AT THE SOUTHEAST CORNER OF LOT 14, BLOCK, 1, ED SMITH
SUBDIVISION; THENCE RUN NORTH O DEGREES 15 MINUTES WEST ALONG THE EAST LINE OF LOTS 14
AND 13 A DISTANCE OF 87.65 FEET TO THE POINT OF BEGINNING;THENCE CONTINUE NORTH O
DEGREES 15 MINUTES WEST SAID EAST LINE OF SAID LOT 13, A DISTANCE OF20.66 FEET; THENCE
RUN SOUTH 89 DEGREES 36 MINUTES WEST PARALLEL TO THE SOUTH LINE OF SAID LOT 13, A
DISTANCE OF 100.0 FEET TO THE WEST LINE OF SAID LOT 13, THENCE, RUN SOUTH O DEGREES 15
MINUTES EAST ALONG SAID WEST LINE A DISTANCE OF 20.66 FEET; THENCE RUN NORTH 89 DEGREES
36 MINUTES EAST PARALLEL TO THE SOUTH LINE OF SAID LOT 13, A DISTANCE OF 100.00 FEET TO
POINT OF BEGINNING.
THE UNDERSIGNED HAS LOCATED
POSSIBLE APPARENT USE OF ADJACENT LANDS.
NO VERIFICATION OF FIREWALL OR WALL MOUNTE
UTILITIES WERE LOCATED TO DETERMINE
OWNERSHIP
LOT 1,
ED
SURVEYOR NOTES
1. THIS IS A BOUNDARY SURVEY.
2. NO UNDERGROUND UTILITIES WERE LOCATED.
3. NO UTILITIES SERVICING BUILDING ATTACHED TO EXTERIOR WALLS
WERE NOT LOCATED.
4. NO DETERMINATION OF OWNERSHIP OF PARTY WALL OR INVESTIGATION
OF FIREWALL.
5. EXTERIOR LOCATION ONLY OF PREMISES.
6. NO BUILDING PLANS WERE AVAILABLE.
7. BEARINGS AND DISTANCES WERE TAKEN FROM THE DEED PROVIDED
BASED ON THE ED SMITH PLAT PB 26 PAGE 50.
GENERAL NOTES.
1. NO UNDERGROUND UTILITIES OR STRUCTURES LOCATED.
2. NO UTILITIES LOCATED EXCEPT AS MAY BE SHOWN HEREON.
3. NO ATTEMPT WAS MADE TO LOCATE JURISDICTIONAL WETLAND LINES
NOR TO NOTIFY THE PROPER AGENCIES.
4. ABSTRACT OF TITLE WAS NOT FURNISHED TO THE UNDERSIGNED.
5. VERTICAL DATUM BASED ON THE N.A.V.D OF 1988.
LIMITED USE AND DISCLAIMER
BY THE USE OF THIS SURVEY, YOU AGREE TO BE BOUND BY THE TERMS WRITTEN ON THIS
SURVEY.
1. THIS SURVEY IS INTENDED FOR SOLE USE OF THE PARTIES CERTIFIED HEREON.
2. NO PARTY SHALL ASSIGN THIS SURVEY DRAWING OR ANY INTEREST OR
OBLIGATION HEREON WITHOUT THE PRIOR WRITTEN CONSENT OF THE UNDERSIGNED.
3. ANY REPRODUCTION OF THIS SURVEY IS PROHIBITED.
9/12/2019 12:47:46 PM
I
FRAMED STORAGE i TWO STORY
GRAVEL /
11 FRAMED
FORMERLY
TOWNHOME
SET RET.
# 1502
CO, PA
ON
IRON PIPE
GRAVEL /
FORMERLY
IO'(DEED)
- - - -
GONG. DRIVE.
COV. PAP 2.2
X
'q TWO STORY
ZZW
FRAMED
eo
TOWNHOME
SET 5.0
RON
�I # 1504
A�� L
j
e m FORME GRAM
--I 388'78'00'II
N IM
AID�"�
p e
FRAMED STORAGE TWO STORY
p
FRAMED
w
e w
40
TOWNHOME
X COV. PAR # 1506
ET
ISE APPARENT �
AC
SEOIL LANDS
SET SO REF.
N69'36TO-E 11
IRON PIPE
COV. PAR
OH
TWO STORY
ED SMITH S/D
57.5
FRAMED
SET a0 R6
TOWNHOME
IRON PIPE
�I
A/C- I.J # 1508
-
0..s
COV. PATI- -
FRAMED STORAGE TWO STORY
A/C
FRAMED
NTS
TOWNHOME
SET 5.0 REF.
# 1510
IRON PIPE
.1�
A/ ILLI 968.3911
WATER xETER I lmvl
Qa'
a
COV. PAR TWO STORY
v
FRAMED SmRAE FRAMED
\
TOWNHOME
e W o
# 1512
p O
Z A/C " 26.61
w Z
k
�
J
2
V
1. THIS IS A BOUNDARY SURVEY.
2. NO UNDERGROUND UTILITIES WERE LOCATED.
3. NO UTILITIES SERVICING BUILDING ATTACHED TO EXTERIOR WALLS
WERE NOT LOCATED.
4. NO DETERMINATION OF OWNERSHIP OF PARTY WALL OR INVESTIGATION
OF FIREWALL.
5. EXTERIOR LOCATION ONLY OF PREMISES.
6. NO BUILDING PLANS WERE AVAILABLE.
7. BEARINGS AND DISTANCES WERE TAKEN FROM THE DEED PROVIDED
BASED ON THE ED SMITH PLAT PB 26 PAGE 50.
GENERAL NOTES.
1. NO UNDERGROUND UTILITIES OR STRUCTURES LOCATED.
2. NO UTILITIES LOCATED EXCEPT AS MAY BE SHOWN HEREON.
3. NO ATTEMPT WAS MADE TO LOCATE JURISDICTIONAL WETLAND LINES
NOR TO NOTIFY THE PROPER AGENCIES.
4. ABSTRACT OF TITLE WAS NOT FURNISHED TO THE UNDERSIGNED.
5. VERTICAL DATUM BASED ON THE N.A.V.D OF 1988.
LIMITED USE AND DISCLAIMER
BY THE USE OF THIS SURVEY, YOU AGREE TO BE BOUND BY THE TERMS WRITTEN ON THIS
SURVEY.
1. THIS SURVEY IS INTENDED FOR SOLE USE OF THE PARTIES CERTIFIED HEREON.
2. NO PARTY SHALL ASSIGN THIS SURVEY DRAWING OR ANY INTEREST OR
OBLIGATION HEREON WITHOUT THE PRIOR WRITTEN CONSENT OF THE UNDERSIGNED.
3. ANY REPRODUCTION OF THIS SURVEY IS PROHIBITED.
9/12/2019 12:47:46 PM
I
I \
GRAVEL /
GRAVEL /
FORMERLY
POINT OF
TANGENCY
CONC. DRIVE.
GRAVEL /
FORMERLY
oRlvE.
bg
GRAVEL /
FORMERLY
IO'(DEED)
1 -_--
GONG. DRIVE.
19
e
X
O
ZZW
8 38
eo
GRAVEL /
�;'
FORMERLY
e m FORME GRAM
CONC. DRIVE.
CONC.
Z eN -C. DRIVE
(DEED) GRAVEL
FORMERLY
W
0
CONC. DRIVE.
�--- �r - -
BEGINNING
3 n B
wz i z
0.01",F SET 5.0 REF.
RON PIPE
7 Sly LINE OF LOT 14 BLOCK
FNOPREF TV oD SMIT
�3"03.WE100.39EDEEDIH S p ..✓
IRON PIPE
O TVCB
DONNER ROAD (40' R/Y/ PER PLAT)
MDT" VARIES (SCALED GIS )
0 20 40
Feet
P L O T S C A L 9-1 S D E P E N D A N T UPON S I Z E O P PAPE R
PLANS ARE 1INCH = 20 FEET IF PRINTED ON 18 X 24 PAPER
PLANS ARE 1 INCH = 33 FEET IF PRINTED ON 11 X 17 PAPER
1. REPLACEMENT OF CONCRETE ONLY "AS IS" AND NO N
ADDITIONAL SQUARE FOOTAGE PERMITTED
2. CURRENT CONDITIONS ARE GRAVEL AND FORMERLY
CONCRETE DRIVEWAYS ON SHOWN RESIDENCES.
100.00' (PLAT)
PART OF LOT 2, BLOCK 2
ED SMITH S/0
0' N89 -36'00-E 100.00' (DEED)
-
4' WOOD FENCE
46.4 m
I \
W
GRAVEL /
PT
POINT OF
TANGENCY
P
100.09•(D
bg
w
ww
1 -_--
QHAVLL
GOING. DRIVE.
6' APPNIDIT
O
FORMERLY
8 38
USE OF LANDS
CONC. DRIVE.
EO STORAGE
,
a
W O
GRAVEL
512
POINT OF
coNa °M�'
W
0
p� O
N
BEGINNING
T w
ET
3 n B
wz i z
0.01",F SET 5.0 REF.
RON PIPE
7 Sly LINE OF LOT 14 BLOCK
FNOPREF TV oD SMIT
�3"03.WE100.39EDEEDIH S p ..✓
IRON PIPE
O TVCB
DONNER ROAD (40' R/Y/ PER PLAT)
MDT" VARIES (SCALED GIS )
0 20 40
Feet
P L O T S C A L 9-1 S D E P E N D A N T UPON S I Z E O P PAPE R
PLANS ARE 1INCH = 20 FEET IF PRINTED ON 18 X 24 PAPER
PLANS ARE 1 INCH = 33 FEET IF PRINTED ON 11 X 17 PAPER
1. REPLACEMENT OF CONCRETE ONLY "AS IS" AND NO N
ADDITIONAL SQUARE FOOTAGE PERMITTED
2. CURRENT CONDITIONS ARE GRAVEL AND FORMERLY
CONCRETE DRIVEWAYS ON SHOWN RESIDENCES.
100.00' (PLAT)
PART OF LOT 2, BLOCK 2
ED SMITH S/0
0' N89 -36'00-E 100.00' (DEED)
-
4' WOOD FENCE
46.4 m
POINT OF BEGINNING(#1512)
LOT 14, BLOCK 1, ED SMITH
PB 26 PG 50
f_
m 46.6
h
S'LY LINE OF LOT LBLOCK 2
TWO STORY
FRAMED
TOWNHOME a
# 1501
DD'-
00.00-
D'--
00.00• (DEED)
TWO STORY
FRAMED
TOWNHOME
# 1503
216
TWO STORY
FRAMED
TOWNHOME
# 1505
COMMON PARTY WA
T - 237
TWO STORY
FRAMED
TOWNHOME
# 1507
O.t
Vs,
TWO STORY
FRAMED
TOWNHOME
# 1509
FRAMED STORAGE
VINYL
STORAGE
-COV PAPO
SDs
24.9
-A/C
J�WED
S10RAC£. PAHO
r MOOD U.6
I \
24.9
GRAVEL /
PT
POINT OF
TANGENCY
GRAVEL/ FOR
PLY
FORMERLY
w
AMED STORAGE
CDNC, DRIVE.
` A/C
GOING. DRIVE.
-- ��-
O
PG
8 38
^ V PATIO
Ww d
EO STORAGE
=RAVEL /
ERLY
GRAVEL
BLDG
POINT OF
coNa °M�'
W
0
FORMERLY
N
BEGINNING
N
ET
CONC. DRIVE.
AC
AIR
CONDITIONER
N'LY UNE OF LOT 1,BLOCK 2
CHORD LENGTH
L
ARC LENGTH
OH
OVERHEAD
ELECTRIC
ED SMITH S/D
57.5
TRACT
PT
POINT OF
TANGENCY
PB
PLAT BOOK
0..s
IRON PIPE
SECONDS
A/C
AIR
CONDITIONER
NTS
NOT TO SCALE
0 CENTRAL ANGLE
sywa rm�
n.,�.IPu,., svroa
EP
WATER xETER I lmvl
ELPx2
\
G
0.5
Qo
e W
go
p r0
rip
GRAVEL /
Of "
Z d
FORMERLY
00
w
CONC. DRIVE.
FORMERLY
GRAVEL / iafl14ER
Ca4c DRD,E.
_
CONIC. DRIVE.
POINT OF BEGINNING(#1512)
LOT 14, BLOCK 1, ED SMITH
PB 26 PG 50
f_
m 46.6
h
S'LY LINE OF LOT LBLOCK 2
TWO STORY
FRAMED
TOWNHOME a
# 1501
DD'-
00.00-
D'--
00.00• (DEED)
TWO STORY
FRAMED
TOWNHOME
# 1503
216
TWO STORY
FRAMED
TOWNHOME
# 1505
COMMON PARTY WA
T - 237
TWO STORY
FRAMED
TOWNHOME
# 1507
O.t
Vs,
TWO STORY
FRAMED
TOWNHOME
# 1509
FRAMED STORAGE
VINYL
STORAGE
-COV PAPO
SDs
24.9
-A/C
J�WED
S10RAC£. PAHO
r MOOD U.6
I \
24.9
F
PT
POINT OF
TANGENCY
1 V. PARO
N
ORV
w
AMED STORAGE
N
` A/C
U
-- ��-
O
PG
W
^ V PATIO
Ww d
EO STORAGE
A
0
APPROX
4ll
BLDG
e
-A/D
W
0
R
N
SEC
N
Abbreviation
Table
Abbrev. Code Descrlptlon
PC
POINT OF
CURVATURE
PT
POINT OF
TANGENCY
POC
POINT ON
CURVE
ORV
OFFICIAL
RECORDS
VOLUME
R/W
RIGHT OF WAY
ROW
RIGHT OF WAY
BK
BOOK
PG
PAGE
POB
POINT OF
BEGINNING
COV'D
COVERED
STRUCTURE
APPROX
I APPROXIMATE
BLDG
BUILDING
CONC
CONCRETE
R
RADIUS
SEC
SECTION
ET
ELECTRIC
TRANSFORMER
AC
AIR
CONDITIONER
CH
CHORD LENGTH
L
ARC LENGTH
OH
OVERHEAD
ELECTRIC
TR
TRACT
PT
POINT OF
TANGENCY
PB
PLAT BOOK
IP
IRON PIPE
SECONDS
A/C
AIR
CONDITIONER
NTS
NOT TO SCALE
0 CENTRAL ANGLE
sywa rm�
n.,�.IPu,., svroa
EP
WATER xETER I lmvl
ELPx2
BANKS & BANKS /HEREBYCERTIFYTO.'
CONSULTING, INC. FULL HOUSE REALTY
83 WEST 9TH STREET ATLANTIC BEACH, FL THAT THIS SURVEY MEETS THE STANDARDS OF PRACTICE AS SET FORTH
BY THE FLORIDA BOARD OF SURVEYORS AND MAPPERS UNDER THE DEPT.
(904)-685-2800 FAX (904)-685-2345 OF AGRICULTURE AND CONSUMER SERVICES, PURSUANT TO SECTION
472.027 FLORIDA STATUTES AND CHAPTER 5J-17.050
A GEOSPATIAI. COMPANY FLORIDA ADMINISTRATIVE CODE
BANKSANDBANKSCONSULTBVG.COM
NOTES
THIS IS A BOUNDARY SURVEY.
FLORIDA REGISTER U WYORS T
FLOOD ZONE "X" AS BEST ASCERTAINED FROM FLOOD PANEL NO
DARYL S. BANKS CERTIFICATE #6063 NO 6063
12031CO408JH DATED 11.2.2018
STATE OF
BEARING DATUM BASED ON THE E'LY R/W LINE OF JORDAN ST BEING NO -15-W.
DATE AUGUST9, 2019
THERE MAY BE ADDITIONAL RESTRICTIONS THAT APPLY BUT ARE NOT SHOWN ON
OR i0P
THIS SURVEY BUT MAY BE FOUND IN THE PUBLIC RECORDS OR FACILITIES OF
SCALE 1INCH =20 FEET9
THIS COUNTY.
JOB NO 17241
THIS SURVEY DOES NOT DETERMINE OWNERSHIP
LICENSE BUSINESS NUMBER 7820
THIS SURVEY WAS ELECTRONICALLY CERTIFIED BY DARYL S. BANKS, PSM 6063, AS TIMESTAMPED ON BORDER.