Loading...
332 4TH ST ROW19-0032 ,,Yt' ''' cp RIGHT OF WAY PERMIT PERMIT NUMBER Si ROW 19-0032 ,�,�"'�_ CITY OF ATLANTIC BEACH " ISSUED: 10/4/2019 Van V 800 SEMINOLE ROAD -0.219r r ATLANTIC BEACH. FL 32233 EXPIRES: 1/2/2020 MUST CALL.INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH.EDITION (2017) OF'THE FLORIDA BUILDING CODE,,NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. . .. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS:, PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 332 4TH ST RIGHT OF WAY COMMERCIAL JEA- MOVE POLE, INSTALL $0.00 • RIGHT OF WAY PULL BOX & UG SERVICE TYPE OF REAL ESTATE BUILDING USE ZONING: SUBDIVISION: CONSTRUCTION: NUMBER: GROUP .. 169816 0000 ATLANTIC BEACH COMPANY ADDRESS: CITY: STATE: I ZIP: JEA s. , OWNER: ADDRESS: CITY: 1 STATE I ZIP: . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS . Roll off container company must be on City approved list. Container cannot be placed on City right-of-way. 1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: 2 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. Issued Date: 10/4/2019 1 of 2 'V'f-ir.,1 RIGHT OF WAY PERMIT PERMIT NUMBER ri CITY OF ATLANTICBEACHROW19-0032�" ISSUED: 10/4/2019800SEMINOLEROADr'�'or3'9 ATLANTIC BEACH. FL 32233 EXPIRES: 1/2/2020 3 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: . Full erosion-control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(904-247 -5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes:. -- Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-Way restoration,including sod,is required. 6 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. FEES,. • .,_. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date: 10/4/2019 2 of 2 rSyLy��� City of Atlantic Beach APPLICATION NUMBER s .r (To be assigned bythe BuildingDepartment) �,.,.„�� :: •�� Building Department 9 P 800 Seminole Road. (���V"n 1 `� '� _ �� Atlantic Beach, Florda 32233-5445. 1 Phone(904)247-5826• Fax(904)247-5845 91- E-mail: building-dept@coab.us Date routed: 9/z (L, I�(.� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Z. 1 Property Address: / ' Department review required. Yes No 3 Building_ Applicant: Building_ &Zoning `� Ri Tree Administrator Project: n k-)V6.- PO Le- QS CA L(, Q ( C"P6lic Work eblic Utilities a Public Safety Fire Services Re,View fee $ Dept.Signature: Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. Not applicable (Circle one.) Comments: BUILDING // � ANNLNG &ZONING 'i Reviewed by: Date: ( 0- I— 19 TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 s=1Lvr City of Atlantic Beach , APPLICATION NUMBER s Building Department �i T°r; ,1� A s� (To be assigned by the Building Department.) `as ;' 800 Seminole Road l� li Row n f 1 ,� Atlantic Beach, Florida 32233-5445c1 ► o �' `A r 3 Z. Jak` ~ .` Phone(904)247-5826• Fax(904)A -5a FP 2 7 2019 ! `` Date routed: 9/z z (- /( ��;tU? E-mail: building-dept@coab.usNI City web-site: http://www.coab.us BY: APPLICATION REVIEW AND TRACKING FORM Property Address: S 3 Z . f4\ �- ` Department review required Yes No Building Applicant: --.. (inning &Zoning .. ��� Tree Administrator . RCProject: T � V� POL.CC—' 1t33 CACC --jD}<, IicWorkks- i 4'F$ublic Utilities ) Public Safety Fire Services Review fee $_ Dep t Si nature _ T Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1 v/Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING ,- PLANNING &ZONING /f Reviewed b - ,f,�,�./",� , , ,,.... Date: ���®�! TREE ADMIN. Second Review: ['Approved as'-revised. ['Denied. Not applicable ,----7- UBLIC'WORKS` Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: ,Date: Revised 05/19/2017 APPLICATION NUMBER ,��J� City of Atlantic Beach- y 'ell Building Department (To be assigned by the Building Department.) ¢ f 800 Seminole Road. � 1 t� Atlantic Beach, Florda 32233-5445 O Phone(904)247-5826• Fax(904)247-5845 E-snail: building-dept@coab.usDate routed City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3 Z -4'44-\___ Department review required Yes No Building Applicant: (---P fanning �C & Tree Administrator R)t Project: V6- POLE �S (AL QCCPu6lic Works ublic-Utilities Public Safety Fire Services IReview fee $: Sf° =' ' Dept Signature ., Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation . St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLIC N STATUS Reviewing Department First Review: Approved. (Denied. nNot applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b : Date: 9 - 30 -17 TREE ADMIN. Second Review: DApproved as re sed. DDenied. ONot applicable PUBLIC WORKS Comments: �I?UBLIC`UTILITIES PUBLIC SAFETY Reviewed by:. Date: FIRE SERVICES . Third Review: DApproved as revised. ❑Denied. nNot applicable Comments: - Reviewed by: . . Date: Revised 05/19/2017 PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: Application#: Project Address: Check Box Check APPLICATION TRACKING COMMENTS to Add Box to Comm Print Underground Avoid damage to underground water and sewer utilities. Verify vertical and Water Sewer horizontal location of utilities. Hand dig if necessary. if field coordination is Utilities needed,call 247-5878. Meter Boxes Ensure all meter boxes,sewer cleanouts and valve covers are set to grade Sewer Cieanout4 and visible. 0 0 A sewer cleanout must be installed at the property line. Cleanout must be RT1 Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade 0 0 Cleanout and visible. A reduced pressure zone backflow preventer must be installed if irrigation will RPZ be provided or If there is a private well on the property. Backflow preventer Backflow must be tested by a certified tester and a copy of the results sent to Public Utilities. Plans note the building will be unsprinkled. If plans change,any fire line Sensus installed must be metered with a Sensus touch-read meter in a properly sized Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer 0 Meter must be tested by a certified tester and a copy of the results sent to Public Utilities. Fire Sprinkler if fire sprinkler system is provided,call 247-5878 for backflow requirements. SOW At a minimum,will require a double check backflow preventer. Requirement Fire Line Fire lines must be metered with a Sensus touch-read meter. Meters larger 0 Meter than 2"must be installed in a vault as noted in JEA specifications. 017 Utility Map See attached Utility Map. Disconnect &Cap Disconnect and cap water and sewer lines. 0 0 Inspection Must call the inspection Line at 247-5814 to request an inspection of the Prior disconnected and capped water and sewer lines prior to demolition. O 0 O 0 O 0 O 0 . . . . . . .. . . .. . . . , . . . . . . . . . . . . . .. . ... . . .. . . . . . . . . . . „ . . . .. „ . . . . _ . . . . . . . . . . „. . . . . . _ ., . . . . . .. .. . . . . . ..... . . . . . . _ . . . . . , .- ......, .. . . .. _ . .. .- ... . . .. ..- • .. ...... .. - . , . .., . . . . , . . . . . . . . . . , . . . . . , ' . , .- . . . . . .. . . . , . , , . . . . ,, • . . . . . • . . . . . . . . ... . , . .. . . . . _ . . . . , . . . . .... . . _.., ..... . . . . .. . . . . . . . , . . . . . . . , . . . . , . , •. . .'.. ..• .". .' , ' . . .. . •„.•,. . . . . , . . . . . . . . . , . . . . ,_ . .. _ .... .. . .. . . _ .. . . .. • , -. . . .. . .. . . . . . . . . , . , . . ,. . . . . . . . , . . . . . . . . . • . ', . . . . . _. . - . , . . .. . . - . . . .. . ..• . . .. „. . . . , . . . . . . . . • ., . , , . . • ._ . . , . . . . . . . . . . . . . ,. , . . , , , . . . . . . , . . . . . . . . . . ,' . . . . . .. . - - . . . . . . ... . ,... . . . . . . .. „_ _ . . . . . . , . , . • „ .. . . . , . . .. . . . . .., .... .. ..: , .. . . , . . . . . . .. . . . . . . . . . . , . . . . . . . . . . . . . , . . . . . , . , .. . . .. . . . . . . . . ... „ , .. . . . . . . . . . . . . _ ,. , .. . . __ . . ... .. . . . . .. . _ „ „ . .. . . . . , . . . . . . . . . . , . . . . . , . . . . . . . . . . . . . . . . . . . ., . , • . . . . . . . . . ' . . . . . . . . . .. . , , . . . . . . . . . . . . . . . . . . .. . . . . . . . . . , . . . , , . - . . . „ . . . . . . .. . , . . . • . , . . . . . . . . . - ... . ._ . _ . .. . . . . , . , . . . . . , .. . ... . . . .. , . . . . . . . . . . , . , . . . . . . . . . . . . . . . . • . . ..• . . .. , . . .. ,. . . , . . . . . . . . . . . . _ ,... -. ,. - . . . . .. _ .. ... . . . . _ .. , . . _ . . . . . . . . . , . . . . . . . . . • . . . . . . .. . . . . . . . . . , . , . . . : ... . . . . . . . . . . . . . . ., - . . . . . . . . . . . . . . . . ,. . . . . .... . _ . . . . . . . .. . _... . . - . . I . . . • . . . . . 1 . . . . . . .. - • . . . . . ... „ . . ... ,- . . -_.. . . .- . ... . .. . . . .. ., . . , . . . . . , . . . . . .,- . . . . . . . . . ; ,. - .. . .,--. -.. ,. ... , .. . _ . . - . . . ... .. . .. - . .,. .. ... .. . . .. . . . . , , • . , - .. , , . . , , . . . . . . . . . . . . . . . 1 . . . . . . . . . , . . . . ; . . . . . . . . - . . . . . . . -- -,• . . . . . • .. . .. . . . , -. . . . . .-. - , . . .. . . . . . . , . . . . . . - . -. • , . .. .... ...„ . - . . . . . . I - . . • . . . . . . 1 . , - ' ..m „ -. . . . . .. . . .. . .. ,.- .- -. , . -. .- ...• . . .. . . ; . . ; . . . .. . - . - . - . .. . , . . , . . . . - . ... - .....-..-- -- • . . . . . • . . i . , . . - . ., . . . .. , •... --- . . .. ... ,.-.. . - . ., . ... . . . . . - . . . . T'''''.,....y.4:1, wl� .fir 4: P 4. tl, .' . , `V . fk 3. III 0 YS 40 t i % s lila Ti �a Ili t a u " A 1 No. 40 1 ti, k. Sf la Ar4444,1,w SEWER MAIN ro ° - A-40 a - ►;4. 4 al L- SEWER LATERAL WATER SERVICE " !... \ * pore ,,i, 7111 4t , , :-. ,y s1iR 111 ii ' C A,� Ge. 0 Ay: ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:40144 N,O,: 8005212 • WO#: 30482397 CONST:09/26/19 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 563 REQ'D:YES CELL ENGINEER:Robert Simpson N,O„ N/A ZIP CODE: N/A CUSTOMER/ SVC PHONE LOCATION: 338 4TH ST.!R&R 45/3W AND TRANS 563 CENTER: SSSC N.O.'.665,7793 r Lri W ! .--.1 "" l Ain� __- Lu - ` P# 338 4TH ST./ R&R 45/3W AND 50KVA. . MOVE POLE TO PROPERTY `, 1 LINE, INSTALL PULL BOX AND RELOCATE EXISTING UG SERVICE. i' � ® ***** TREE TRIMMING REQUIRED ***** 300 ***** NEW HOME BUILD ***** 310 0 (450) to. t/,„\ , �� ***** NARROW ROAD ***** 317 3 09 , t 2 3 5 3 � I, ,di t45 3 ' 5 ' 3 40 0 1 4 NW0 ' '1 t HI P# 338 1/OT /OP 4T 1/0T 4T 2 0P 1 - __- 4TH ST ..�-- ) o;t . as A O 6 r---o°1 } (I1 W �l Cn) T CP 0 Lno. 0 4T 306 o .P 4T ° ° 1/OT 1/OT 308 '' 1/0 ,° �, o 0 \, ON 0 y 4 00 318 31`► 310 3 z4 0 338 4 322 3 50B .0 344 340 332 /,.• 34.6 Q w d 0 rc'`'i%� RIGHT-OF-WAY/EASEMENT PERMIT APPLICATION **ALL INFORMATION ' °j•': City of Atlantic Beach HIGHLIGHTED IN GRAY IS p ;i+'ia �.:= ' 800 Seminole Road,Atlantic Beach,FL 32233 REQUIRED: `amu::0- . • PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES ` I Job Address. 33 Z 1 7---1--' iS .. Permit Number 1'�O k) ` 9 -co a • Contractor Information ' Company J$19. / / Qualifying Agent Address 7i 1 . Vest- (/Nv'(//'+.CA : 5t, City 'TAX • State .pi Zip .,?Z•2,61 Phone Email State Certification/Registration# - . • Architect Phone Email Engineer - �i���SL9v� I` Phone 66c--2793Email.foal iZ b@i fern. G0,"--7 Workers Compensation Insurers • OR Exempt❑Expiration Date • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation,alteration or relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles, wires,pipes;cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet CityofAtlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of R. ,cL , sc9� • (Project Superintendent) with(Company Name) 7" (4 Phone (,/J..-- 779 3 • • All materials and equipment shall be subject to inspection by the Public Works Director. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the ' • manner satisfactory to the City. • A sketch of plans covering details of this installation,as wellas a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • • The permittee shall commence actual construction in good faith within ' ' days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • Th I or; •'•-c•or shall be notified 24 hours prior to starting work and again Immediately upon completion. �' Al z • 9/ ��g i Date Permittee(signed in presence of•,otary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of. ,20• by • ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. • [ ]Personally Known Signature of Notary Public,State of Florida [ ]Produced Identification(Type) . H:\Applications&Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date:10/1/18 JEA. CUE Reports Estimate Number:40144 338 4TH ST:/R&R 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30482397 Required Date: Oracle Project#:8005212 Estimated On: 09/23/2019 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $1,232.84 $1,232.84 2.Transformer Cost(w/sales tax) $1,436.87 $1,436.87 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $1,716.77 $1,547.29 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(43.52%of lines 4&7) $868.73 $121.59 7.Engineering Costs(Variable%of line 4) $279.40 $279.40 8.Project Equipment Costs(40%of total equipment costs) $1,015.56 $0.00 9.Material Handling(6.67%of lines 1&2) $178.07 $178.07 10.Inspection(6.84%of line 4) $0.00 $105.83 11.Total Cost of Project $6,728.25 $4,901.91 12.Work Order Estimate(Line 11 minus line 8,9,&10) $5,534.62 $4,723.84 13.Billable Equipment Depreciation(60%of total equipment costs) $1,523.33 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(64.49%of 4&7)) $9,538.91 $5,082.09 15.Billing Estimate(W/O Transformer Cost)(Lines 11+13+(64.49%of 4&7)-Line 2) $8,102.04 $3;645.22 Time Estimate Crew Hours Total Manhours 13.77 55.06 CUE Reports Estimate Number:40144 338 4TH ST./R&R 45/3W Estimate Type:SR Contract:069-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30482397 Required Date: Oracle Project#:8005212 Estimated On: 09/23/2019 CU Detail Build Transfer Remain in Place Remove CUT 3 DA 1 F-5*2 1 DGAC*50 1 G1W*2 1 HANDDIG 10 MSERV-BOX-D*H 1 P.45/3W 1 S20ES*4/0-1/0 2 S4*4/0 1 S9*1/0 2 UCL9*3 3 USRW*350 1 USS*500B 1 ARRESTER 1 BANK10 1 CLAMP 1 CUTOUT 1 DEYE 1 EYENUT 1 FULLGRD 1 NUMBER 1 P.45/3W 1 PIN 1 POLECON 2 • PRIINS 1 • SMWEDGE 2 STANDOFF 1 SWITCH 1 USRW*2/0 1 Nfr� ..! CUE Reports Estimate Number:40144 338 4TH ST./R&R 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30482397 Required Date: Oracle Project#:8005212 Estimated On: 09/23/2019 Wiaterial Summary Item Quantity Item Number Item Description 1 ARRLI003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER POLE (MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL VOLTAGE 1 BKTAC009 BRACKET,ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM MATERIAL OVER ROD TYPE:SINGLE PHASE 1 BKTFS001 BRACKET, FIBERGLASS STANDOFF,2" FIBERGLASS ROD, 18" STANDOFF TO INS BASE ROD COVERED WITH RAYCHEM HEAT- SHRINK MATERIAL, DUCTILE IRON FITTINGS 1 BOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV.WITH 4 SQUARE NUTS ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 BOLMS020 BOLT, MACHINE, 5/8"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 50 EACH) 4 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 1 BOXSE002 BOX, SERVICE, REINFORCED PLASTIC/POLYMER COMPOSITES, 24"W X 36"L X 18"DP, H10-LOADING (SEE JEA TECHNICAL SPECIFICATION FOR DETAILS) USED ON HOUSE SECONDARY SPLICES AND CONNECTIONS. TOP TO BE MARKED"ELECTRIC" (SHIP ON FLATBED ONLY) 45 CAIUS003 CABLE, 350 URD, UNDERGROUND SERVICE, "CONCORDIA OR WESLAYAN"XLP INSULATION, 600 VOLT, TRIPLEX 1000'MINIMUM REEL LENGHT. 1 CLAGROO1 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 2 CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:#6.-2/0 1 CLASS006 CLAMP, STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM (STD PKG 15 EA) 1 CLATG001 CLAMP,TRANSFORMER TANK GROUND, "BRONZE"6 SOL-1 STR. 2 CNNCP002 CONNECTOR,#2,6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 4 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, • 4 CNNCP006 CONNECTOR,#6, 1/0-2/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 2 CNNCP008 CONNECTOR,#5, 6-2 MAIN, 4/0 TAP, COMPRESSION, PARALLEL TAP, ALUMINUM, 2 CNNGROO2 COUPLING, GROUND ROD, "THREADLESS"REMARKS: FOR THREADLESS GROUND RODS 1 CNNSP001 CONNECTOR,SECONDARY PEDESTAL,4-OUTLET#10-500-KCM 3 CNNTS009 CONNECTOR, CONTAMINATED ENVIRONMENT,TRANSFORMER SECONDARY SET SCREW TYPE WITH INHIBITOR, 1/2" STUD, RANGE: 12-350, 6-PORTS. 3 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 23 COBCO028 CONDUCTOR,#4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#,ON PLASTIC REEL,4"X 11.5"W/2"HOLE CUE Reports Estimate Number:40144 338 4TH STI R&R 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 ' Estimate Version: By: SIMPRB MWO#/Task:30482397 Required Date: Oracle Project#:8005212 Estimated On: 09/23/2019 70 COBCW014 CONDUCTOR, #4,TYPE 40 DSA, COPPERWELD&COPPERWELD- COPPER .204" DIAMETER 1480#BREAKING STRENGTH (50#COIL- 427 ) 3 CODEP004 ELBOW, PVC, CONDUIT, 3", 90-DEGREE 36"SWEEP-RADIUS, SCH-40, WITH INTEGRAL BELL END 1 CODKT001 KIT, RISER PLUG, FOR CONDUIT RISERS AND CABLE GUARDS UP TO 6" DIAMETER. 10 COVIC002 COVER,"0"DIE, INSULATING,2-112" 1 CUTOT006 CUTOUT,CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE • TO GROUND, 100A,27 KV, 170 KV BIL (54 EA PER PALLET) 1 FUSOH024 FUSE, OVERHEAD DISTRIBUTION, 3.1 AMP, TRANSFORMER. 3 GUACA004 GUARD, CABLE, 3"X 10',SCH-40 PVC, (50 EACH PER BUNDLE FOR DELIVERIES) ( 150 EACH PER SKID), MUST BE PALLETIZED FOR OUTDOOR STORAGE NO CARDBOARD BOXES WILL BE EXCEPTED, SHIP ON OPEN FLATBED ONLY! 1 GUAGW001 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 1 INSS0002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#; GALV. FITTINGS 1 INSVP001 INSULATOR, VERTICAL POST,TIE TOP 35-KV, 3/4."STUD TAP STANDARD PACKAGING IS NOT TO EXCEED THREE UNITS OR 72 POUNDS. 2 NUTSL003 NUT, LOCK, SQUARE, 5/8"HOLE SIZE, HOT DIPPED GALVANIZED 2 NUTSLOO4 NUT, LOCK, SQUARE, 3/4"BOLT SIZE, HOT DIPPED GALVANIZED 1 POLW0006 POLE, WOOD,45'CLASS 3 (T/L=26),WEIGHT=1,770 LBS 3 RODGR003 ROD, GROUND, THREADLESS, 5/8"X 8',SHIP ON OPEN FLATBED ONLY! 20 SCWLA005 SCREW, LAG, 1/4"X 2", MECHANICALLY GALVANIZED, MODIFIED GIMLET POINT W/HOT-DIPPED STEEL WASHER W/ATTACHED UV STABILIZED RUBBER WASHER, INS. ITEM, USED FOR INSTALLING CABLE GUARD ON WOOD POLES, (STD PKG =500) 2 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL SPLICING 1 STULI001 STUD, LINE POST, DIA.SHANK-3/4", SHANK LENGTH-1-3/4", GALVANIZED STEEL W/NUTS AND WASHERS; 3/4"HEAD SIZE 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" • WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 1 TIEPROO1 TIE, PREFORMED LINE,#2 AAAC, 23" MIN. LENGTH, "F" NECK, SIDE TIE .316"-.357"COND. RANGE 1 TRAC0002 TRANSFORMER, 50 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT SECONDARY, SINGLE PHASE, CONTAMINATED ENVIRONMENT-JEA SPECIFICATION REQUIRED 2 WASRD004 WASHER, ROUND, 5/8"BOLT SIZE X 1 3/4" DIAMETER, GALVANIZED, 650 EA P/BOX) 9 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2"DIAMETER, GALVANIZED,*** 500 EACH PER BOX*** 5 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 5/8"X 3/4"BOLT SIZE, GALVANIZED CUE Reports Estimate Number:40144 338 4TH ST.!R&R 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30482397 Required Date: Oracle Project#:8005212 Estimated On: 09/23/2019 3 WASSP002 WASHER, SPRING,3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED(EXTRA HEAVY DUTY) CUE Reports Estimate Number:40144 338 4TH ST./R&R 45/3W Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30482397 Required Date: Oracle Project#:8005212 Estimated On: 09/23/2019 CU Summary '„ a i,. CU Name Quantity Description CUT 3 CUT POLE OR CROSSARM DA1F-5*2 1 2 TANGENT TO 10 DEGREE ANGLE—UNSHIELDED, CONTAMINATED DGAC*50 1 TRANS; CI, 26.4KV 120/240 50KVA G1W*2 1 WOOD POLE— EQUIPMENT GROUND HANDDIG 10 NO DESCRIPTION... MSERV—BOX— 1 POLYMER CONCRETE SERVICE BOX D*H P.45/3W 1 45 FT. CLASS 3 WOOD POLE S20ES*4/0-1/0 2 SECONDARY CONNECTION AT POLE S4*4/0 1 SECONDARY DEADEND S9*1/0 2 SECONDARY SPLICE UCL9*3 3 INSTALLATION OF CONDUIT ELL USRW*350 1 UNDERGROUND RESIDENTIAL SERVICE OH POLE USS*500B 1 SECONDARY SPLICE 5.• Xa CU Name. Quantity Description ARRESTER 1 DIST.ARRESTER REMOVAL BANK10 1 SINGLE TRANS. REMOVAL, UP TO 75KVA CLAMP 1 HOT—LINE CLAMP REMOVAL CUTOUT 1 FUSE CUTOUT REMOVAL DEYE 1 S6 REMOVAL EYENUT 1 EYENUT REMOVAL FULLGRD 1 EQUIPMENT GROUND REMOVAL NUMBER 1 POLE TAG REMOVAL P.45/3W 1 45 FT. CLASS 3 WOOD POLE PIN 1 INSULATOR PIN REMOVAL POLECON 2 S20 REMOVAL PRIINS 1 PRIMARY INSULATOR REMOVAL SMWEDGE 2 SMALL SEC.WEDGE CLAMP REMOVAL STANDOFF 1 PRI. INSULATOR STANDOFF BRACKET REMOVAL SWITCH 1 CUTOUT&ARRESTER BRKT. REMOVAL USRW*2/0 1 UNDERGROUND RESIDENTIAL SERVICE OH POLE