948 Hibiscus St FIRE19-0005 Install Fire Alarm System r1-1..A' FIRE PERMIT PERMIT NUMBER .. _� FIRE19-0005 , .v.,,, ,. �, CITY OF ATLANTIC BEACH ISSUED: 10/28/2019 \ 800 SEMINOLE ROAD uft"~ ATLANTIC BEACH. FL 32233 EXPIRES: 4/25/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: I VALUE OF WORK: 948 HIBISCUS ST FIRE ALARM install fire alarm system $3300.00 TYPE OF I REAL ESTATE BUILDING USE ZONING: SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 170948 0640 ATLANTIC BEACH SEC H COMPANY: ADDRESS: CITY: STATE: ZIP: KENTRONIX 350 ELDRIDGE AVE #1 ORANGE PARK FL 32073 OWNER: ADDRESS: CITY: STATE: ZIP: NEWSOME SHERALLA 1970 FRANCIS AVE ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ADMINISTRATIVE FEE 455-0000-322-1000 0 $35.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $39.00 Issued Date: 10/28/2019 1 of 1 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department) 800 Seminole Road — ?( Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 I I f, F'ss !).$.> E-mail: building-dept@coab.us Date routed: ` SL ` I City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 0 f t1 tc scut .S Sk Department review required Yes No Building Applicant: LLn -Vc.)(1 v X Planning &Zoning Tree Administrator Project: 1 nSt"i4,Lk ! 0_ 4\-41.1M '•ii } Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By i Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ,Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: 1,0 I iril Date: 404510 TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: q PUBLIC UTILITIES t Z Z ( ` t � PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Electrical Permit A„p Application **ALL INFORMATION r `,, PCity of Atlantic Beach Building DepartmentGRAY IS REQUIRED. � ' 800 Seminole Rd, Atlantic Beach, FL 32233 HIGHLIGHTED IN Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: F1 () Ll6f—u t -> JOB ADDRESS: c7 Ll i N; h i SCtiS .5r'tet- PROJECT VALUE $ JEA INFORMATION REQUIRED ON ALL PERMITS: AMPS VOLTS PHASE IT NEW SERVICE: 0 Overhead DUnderground ❑Underground up Pole DResidential (Main)Service: 00-100 amps Q101-150amps 10151-200amps 0 amps #of Meters [Commercial (Main)Service: 00-100 amps 0101-150amps 0151-200amps ❑ amps OCT Service amps Conductor Type Size ®Multi-Family(Main)Service: 00-100 amps 0101-150amps 0151-200amps 0 amps #of Unit Meters fl TEMPORARY POLE: amps f r`— © 1 JJ ig , li C SERVICE UF'GRAUE: L] amps OCT Service amps il JUL 3 0 2019 ❑ NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.): 0100 amps 0150amps 0200amps 0 amps 1QcT Service amps ❑ ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS,ACCESSORY STRUCTURES, ETC: Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS: ❑Swimming Pool Sign ❑Smoke Detectors (Qty) ❑transformers KVA ['Motors HP E FIRE ALARM SYSTEM (Requires 3 sets of plans): Qty 13 volts/amps foii / REPAIRS/MISCELLANEOUS: ❑Replace Burnt/Damaged Meter Can OSafety Inspection ❑Panel Change ❑OH to UG [Other: Updated 10/17/18 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the rovisions of any other state or local law regulation construction or the performance of construction. 54 Ns v/'-7 C Owner Name: � 1s�'.� -� � 'Q r..,Phone Number: —,�� Electrical Commit/sof ii `C�04Y'4,'N c yL Office Phone: n77'7—5—`l'' > Fax: Co.Add�1�'`�% d�� l4� / �c y� AI ( City: Ll,---40-77, Ark State: '- Zip: ?� 9.3 0‘;.••• • / l Licer h o �► $A-L, tiCi St,—e t ficationegistration#: I /- 9&D ) r 7 Note dSign^�anttur �.�l�rsti Holc>� 3 - . : lWm ZW" S r !-. r The.foregoi; Gres jcknowledged before me this 1,54 day of Fru.. 1 ,206 , in the State of Florida,County of GG 111°' • Q _ $0. j Q Z. Signature of Notary Public �:�f of S'i•'••.F,.g�:•''�OQ��� [ ] Personally Known OR[ P'••uced Identification ��'//- TE OF %`��� Type of Identification: " J <<ti I),, ,� �£.( i"111111W' ALL Revision Request/Correction to Comments **HIGHLI HIGHLIGHTED ON HIGHLIGHTED IN .7441"r-'"•' City of Atlantic Beach Building Department GRAY IS REQUIRED. o 800 Seminole Rd, Atlantic Beach, FL 32233 -`°"'r Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: rjrc /9 - 0005 Revision to Issued Permit OR Corrections to Comments Date: /ci(e Z1 Po/ 9 Project Address: 9( {'/r`4,3c.0 SFS«r ; 4 r/04 r/c I'«!c 4 PL . Z Contractor/Contact Name: /}/n....1 Ce,ry-01 c x/34 ;A Contact Phone: 9Utt - 77 7- S '1OO Email: t. a'7 lv.r a /c <�f-�-,; t<c�, }, , et"-, Description of Proposed Revision/Corrections:/ / �Ct c/l (' �j.tir d ty derec ., Q.av,,f Y'•t�( /raga phi'I AI" al At/.' /cifc 4r,7 44(1 j•`Yi� ray.., ��✓ <G '&7J( . I 1-0,14-, %.,'I/1'q„r affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Wi roposed revision/corrections add additional square footage to original submittal? No ❑ Yes (additional s.f.to be added: • Wjjkroposed revision/corrections add additional increase in building value to original submittal? �No ❑*yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: �. (Office Use Only) V'Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments r tai- ii\???„of-t r D(22.101 Department Review Required: Building PTanning&Zoning Reviewed By Tree Administrator Public Works Public Utilities ( (z. St 1 Public Safety Q Fire Services Updated 10/17/18 ir_ `r Jacksonville Fire Rescue Department Fire Plans Review-Fire Prevention Division 214 N.Hogan Street,Room 281 Jacksonville,Florida 32202 Fire Alarm - Return for Corrections CONTRACTOR: Kentronics PROJECT NAME: Sharella Newsome Group Home PERMIT #: FIRE19-005 Atlantic Beach Please correct or provide the requested information to obtain plans approval. Return this correction notice with your re-submission. • initials ✓SLG- Have you provided a written narrative responding to our comments and directing the plans reviewer to the sheets changes have taken place? YES NO • Initials ►9-' Have the revised sheets been clouded, clearly showing the areas were changes or corrections have occurred? YES ✓ NO • Initials k2(, ' Are the re-submittals neatly bound? YES/ NO • initials hLN- Have you included a copy of the original marked up drawings by the plans reviewer for reference? YES NOV • Initials 191, t.•,Are you in compliance with the "JFRD Fire Alarm Plan Submittal Requirements"effective 11/26/2018 Rev. 1.6? YES ✓ NO I understand that answering the questions above and initialing is mandatory. Answering with a "NO"or failure to initial/answer the above will result in a "Return� For Correction". Printed Name /�et .'cr 4•(f 'c�3Sign ature Z-,--7,6—Date t— Date /6//X7/9 Failure to print name/sign and date above will result in a "Return for Corrections 8/15/19 Fire Inspector Mark Wertz—904.255.8557—mwertz@cni.net 1. Visual notification appliances not in compliance per 2015 NFPA 101 Chapter 9.6.3.5 >>» 2013 NFPA 72 Chapter 18.5.5.4.2 "Marked red Xl" 2. Smoke Detector above FACP. 2013 NFPA 72 Chapter 10.4.4 "Marked red X2" ,ce u" ra Fire Alarm — Return for Corrections Kentronix Security Project Name: Sharella Newsome Group Home Permit#: FIRE 19-005 Mark, I have added a smoke detector above the fire alarm panel, and I have also updated the battery calculations to represent the change. We also added a strobe to the living room area and the kitchen area to meet NFPA requirements. The battery calculations have been updated to reflect these changes also. I do not have the original plans that were returned for corrections. Regards, --21.1. 4. - /cif /7/70/ David Landon Williams Date Conventional Initiating Edwards Signaling Rate-of- rise/Fixed . . . .. .. .•.. ... ‘ ,.,,,„. :.. . : .,.. • . „,_ , . Temperature4. '1EE DET E i ` � nr � .,.Heat Detectors 280B-PL Series CO ® O w t Overview Standard Features 280B-PL Series heat detectors offer fixed temperature or combi- • UL listed for 50 ft.(15.2m)spacing nation rate-of-rise and fixed temperature detection. • Single pole — normally open contact RATE-OF-RISE:A temperature increase at the sensor of 15°F • Low profile with mounting plate (9°C)or more per minute activates the rate-of-rise feature.This • Pure white finish closes the contacts in the sensor to transmit the alarm condition • Mounting flexibility with screw terminals to the fire alarm control panel.When the rate-of-rise element alone has been activated,the sensor is self-restoring. • Easy twist-on installation FIXED TEMPERATURE: If the temperature of the center disk • On-site testing of rate-of-rise feature rises to the sensor's rated temperature,the fixed temperature • Positive operating indication —for fixed temperature element element activates.This closes contacts in the sensor and trans- mits an alarm condition to the fire alarm control panel.The fixed temperature element is non-restorable and,when activated,the Application detector must be replaced.The need for replacement is indicated Heat detectors are most suitable for environments where rapid fire when the center disk has fallen free from the detector. development can be expected.When selecting the location on the ceiling for the heat sensor,do not locate it in direct path of hot or cold air flow. Refer to the detector specifications for the recom- mended maximum spacing. Earlier detector response may be OFFICE, Co Pv obtained by reducing the spacing between detectors. Installation Edwards 280B series heat sensors come standard with a white plastic reversible mounting plate.The plate is designed for surface or flush mounting and installs directly to a standard North Ameri- can 31/2 or 4 inch octagon box. Once the mounting plate is fixed,a simple twist will lock the sensori It can be removed using a screwdriver to release the tamp - si locking finger.This helps prevent unauthorized removal. 0O Ay„ Page 1 of 2 DATA SHEET S85001-0261 Not ,o be used for installation uurposet Issue 4 Mounting The plastic mounting plate is molded to accommodate H INSTALL ON exposed wiring. DETECTOR ABSMOUNTING PLATE.PUSH SUP AND TURN ELECTRICAL (NM BOX CLOCKWISE. �71.111T EDWARDS �I+m' 10 REMOVE DETECTOR– MeuN LIFT LOCKING FINGER Me CmJKt WIH°p a United TectIRotoOlec SCREW DRIVER TIP AND TURN DETECTOR COUNTER- CLOCKWISE OUNTE-CLOCKWISE Contact us... mess' Phone: 1-800-336-4206 2 LOCKING FINGERS Web: www.edwardssignaling.com SURFACEFLUSH SURFACE MOENi1N0� ----/SIDEENTNO 5� AN N0 MOUNTING . Edwards Signaling is SIDE 447 an EDWARDS brand. 3 Farm Glen Boulevard �t Farmington,CT 06032 p2 mm1 s NTE Jrta 2SNAP.OUTS;I t' In Canada,contact Chubb Edwards... E R WIREANCOW Email: inquiries@chubbedwards.com Web: www.chubbedwards.com �� ©2013 UTC Fire&Security Americas l— FLUSH MOUNT FRONT VIEW ��. BREAK AWAY 2 SECTIONS MOI Mw,iing PU?*PIN 280.MPL Corporation,Inc.All rights reserved. i52mml FROMT VIEW ON CIRCUMFERENCE wd r ve.ery) Specifications subject to change P IC fle erc°le Mounting Plate Cm.No.2BDAFL without notice.Edwards is part of UTC Climate,Controls&Security,a unit of United Technologies Corporation. Specifications Catalog Number 281B-PL 282B-PL 283B-PL 284B-PL UL Temperature Rating 135°F(57°C) 194°F(90°C) 135°F(57°C) 194°F(90°C) UL Max Ambient Temp.at 100°F(38°C) 150°F(66°C) 100°F(38°C) 150°F(66°C) Ceiling Fixed Temperature and Rate-of- Detector Type Rise Rate-of-rise: Fixed Temperature Only 15°F(9°C),self restoring UL Recommended Cover- age' 2,500 ft 2(232 m2) UL Recommended Spacing 50 ft.(15.2 m) FM Recommended Spacing 30 ft.(9.14 m) UL Maximum Distance from 25 ft.(7.6m)from any wall or projection extending down from the Wall ceiling more than 12 inches(305 mm) Contacts—Rating Single Pole Normally Open 3.0 amps at 6 to 125 Vac;1.0 amp at 6 to 24 Vdc;0.3 amps at 125 Vdc;0.1 amps at 250 Vdc WARNING-Use For Property Protection Only:Heat sen- Operating Environment Indoor—Dry sors do not protect life against fire and smoke.In most fires, Agency Listings UL,FM,CSFM hazardous levels of smoke,heat and toxic gases can build up before a heat detector would initiate an alarm.Independent °Maximum detector coverage has been determined by UL to provide detection time equal to sprinkler devices studies indicate that heat detectors should only be used when spaced at 10 ft(3.05m) intervals on a smooth ceiling 15 feet 9 inches(4.8m)high.Higher ceilings may adversely property protection alone is involved.In cases where life safety affect detection time.Farber detection may be obtained by reducing the spacing between sensors.(See NFPA 72, is a factor,the use of smoke detectors is recommended. Chapter 5) Under no circumstances should heat detectors be relied upon as the sole measure to ensure fire safety.However,if they are spaced in accordance with the directions in the Specifica- tions table,these sensors can contribute,within an overall Ordering Information fire safety program,to reducing the risk of avoidable property losses. Cat.No. Description Ship Wt. lb(kg) 281 B-PL Heat Detector;135°F(57°C),Rate-of-Rise and Axed Temperature 282B-PL Heat Detector,194°F(90°C),Rate-of-Rise and Fixed Temperature 1.0 (0.5) 283B-PL Heat Detector,135°F(57°C), Fixed Temperature 284B-PL Heat Detector,194°F(90°C), Fixed Temperature Detector Accessories 280A-PL Plastic Mounting Plate —White,Reversible(include OS) A 4100, p c G Page 2 of 2 S85001-026 Issue 4 DF-52416:D•A3-20 MS-5UD(E)/MS-10UD(E) Series , Fire'ure°Alarm$ Five Zone Fire Alarm Control Panel � Ten Zone Fire Alarm Control Panel by Honeywell Control/Communicators General The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel)and the MS-1OUD-7(E)is a ten-zone FACP.These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors.These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such - as two-and four-wire smoke detectors,pull stations,waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document • for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm,Trouble,and Supervisory)and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone -Strobe Synchronization for System Sensor, Wheelock, line integrity. Gentex,Faraday,or Amseco devices. Activation of a compatible smoke detector or any normally- -Selective Silence(horn-strobe mute). open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the -Temporal or Steady Signal. piezo sounder at the FACP, activate the communicator and -Silenceable or Nonsilenceable. FACP alarm relay, and operate an optional module used to • Optional CAC-5X Style Z (Class A) Converter Module for notify a remote station or initiate an auxiliary control function. NACs and IDCs(2 required for MS-10UD-7). New options include a UL listed printer, PRN-6F and FireLite's • Form-C Relays for Alarm, Trouble and Supervisory- Con- IPDACT Internet Monitoring module. The FireWatch Series tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC(resistive). internet monitoring modules IPDACT-2 and IPDACT-2UD per- • 3.0 A total system current for MS-5UD-3. mit monitoring of alarm signals over the Internet saving the • 7.0 A total system current for MS 10UD 7. monthly cost of two telephone lines.Although not required,the secondary telephone line may be retained providing backup • Optional Dress Panel DP-51050 communication over the public switched telephone line. • Optional Trim Ring TR-CE for semi-flush mounting. NOTE: The MS-5UD-3E and MS-10UD-7E offers the same fea- • 24 volt operation. tures as the MS-5UD-3 and MS-10UD-7 but allow connection to • Low AC voltage sense. 240 VAC. Unless otherwise specified, the information in this data • Alarm Verification. sheet applies to both the 120 VAC and the 240 VAC versions of these panels. • PAS(Positive Alarm Sequence). NOTE:For ULC-listed models,see DF-60440. • Automatic battery trickle charger. • Up to eight ANN-BUS annunciators: Features -Optional 8 zone Relay Module ANN-RLY. • Listed to UL Standard 864,9th edition. -Optional LED Annunciator Module ANN-LED, • Built-in DACT(Digital Alarm Communicator/Transmitter). -Optional Remote Annunciator ANN-80. • Style B (Class B)IDC(Initiating Device Circuit) -Optional Remote Printer Gateway ANN-S/PG. -MS-5UD-3-five IDCs. -Optional LED Annunciator Driver ANN-I/O. -MS-10UD-7-ten IDCs. • Optional 4XTMF module (conventional reverse polarity/city • Style Y(Class B)NAC(Notification Appliance Circuit)-spe- box transmitter). cial application power PROGRAMMING AND SOFTWAR.O -MS-5UD-3-four NACs. • Can be programmed at the panel with nial software -MS-10UD-7-four NACs. or additional equipment. • Notification Appliances may be programmed as • Programmable Make/Break Ratio. OA' -Silence Inhibit. • Upload/Download(local or remote)of program and .- - -Auto-Silence. integral DACT. DF-52416:D•07/26/2010—Page 1 of 4 USER INTERFACE: • SYSTEM RESET(lamp test) • Built-in DACT(Digital Alarm Communicator/Transmitter). • DRILL • Integral 80-character LCD display with backlighting and keypad. Terminal Blocks • Real-time clock/calendar with automatic daylight savings AC Power–TB1: adjustments. • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, • ANN-BUS for connection to remote annunciators. 1.00 A. • Audible or silent walk test capabilities. • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, • Piezo sounder for alarm,trouble,and supervisory. 0.54 A. • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, Controls and Indicators 3.80 A. LED INDICATORS • MS-10UD-7E (FLPS-7 Power Supply):240 VAC,50/60 HZ, 2.20 A. • FIRE ALARM(red) Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. • SUPERVISORY(yellow) Supervised,nonpower-limited. • TROUBLE(yellow) Battery(sealed lead acid only)–J12: • AC POWER(green) • Maximum Charging Circuit-Normal Flat Charge:27.6 VDC • ALARM SILENCED(yellow) • @ 1.4 A.Supervised,nonpower-limited. CONTROL BUTTONS • Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E),• ACKNOWLEDGE and 26 AH battery for MS-10UD-7(E).[Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries • ALARM SILENCE require separate battery box such as the BB-26 or BB-55.] Dept=5.207"(13.23 cm) Top •,•••••••••00.0•••••••••a•o••••••.,•oe•••••••••• 4 Door=16.821"(42.73 cm) 1. Depth= Backbox=16.65"(42.29 cm) 14 .257"— I (13.353 cm) � [ Door=19.26"(48.92 cm) Backbox=19.0"(48.26 cm) Left Side Right Side •e•••••••0000ao,•••oa00000aoove••••••,••.o•>e••• Bottom ; �. Vo 46 Nar Cabinet Measurements 0 OA Page 2 of 4—DF-52416:D•07/26/2010 • Minimum Battery Size:7 AH. MS-10UD-7E: Same as above with 240 VAC FLPS-7. Initiating Device Circuits—TB4 (and TB 6 on MS-10UD-7 IPDACT, IPDACT 2/2UD Internet Monitoring Module: only): Mounts in bottom of enclosure with optional mounting kit(PN • Alarm Zones 1 -5 on TB 4(MS-5UD-3 and MS-10UD-7). IPBRKT). Connects to primary and secondary DACT tele- • Alarm Zones 6 10 on T66(MS 10UD 7 only). phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible • Supervised and power-limited circuitry. Teldat Visoralarm Central Station Receiver.Can use DHCP or • Operation:All zones Style B(Class B). static IP. (See data sheet DF-60407 for more information.) • Normal Operating Voltage:Nominal 20 VDC. IPBRKT:Mounting kit for IPDACT in common enclosure. • Alarm Current: 15 mA minimum. IPSPLT: Y Adaptor option to allow connection of both panel • Short Circuit Current:40 mA max. dialer outputs to one cable input to IPDACT(sold separately). • Maximum Loop Resistance: 100 ohms. OPTIONAL MODULES • End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- CAC-5X:Optional(Class A)Converter Module.Converts Style listed). B(Class B) Initiating Device Circuits to Style D (Class A);and • Standby Current:2 mA. Style Y (Class B) Notification Appliance Circuits to Style Z • Refer to the Fire•Lite Device Compatibility Document for listed (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- compatible devices. 7(E)main circuit board and to J7 on the MS-10UD-7(E). Notification Appliance Circuits — TB5 (and TB 7 on MS- NOTE: Two Class A Converter Modules are required for the ten- 1OUD-7 only): zone panel. • Four NACs 4XTMF:Transmitter module. Provides a supervised output for • Operation:Style Y(Class B) local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble • Special Application power LED.A module jumper option allows the reverse polarity circuit • Supervised and power-limited circuitry to open with a system trouble condition if no alarm conditions • Normal Operating Voltage:Nominal 24 VDC exists.Mounts to the main circuit board connectors J4 and J5. • Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A COMPATIBLE ANNUNCIATORS maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- mum per NAC. ANN-80: Remote LCD Annunciator. Mimics the information End-of-Line Resistor:4.7K ohm, 1/2 watt(Part#71252) displayed on the FACP's LCD. Red. (For white, order: ANN- • 80-W.) • Max.Wiring Voltage Drop:2 VDC ANN-LED: LED Annunciator with three LEDs for each zone: Refer to the Fire•Lite Device Compatibility Document for com- Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) patible listed devices. dress panel.Fled.(For white,order ANN-LED-W.) Form C Relays—TB8: ANN-RLED: LED Annunciator with three alarm (red) indica- • Relay 1(factory default programmed as Alarm Relay) tors for up to 30 input zones or addressable points. (Red. For • Relay 2 (factory default programmed as fail-safe Trouble white,order ANN-LED-W.)(See DF 60241). Relay) ANN-RLY: Relay module. Mounts inside the cabinet. Provides • Relay 3(factory default programmed as Supervisory Relay) ten Form C relays. Special Application Resettable Power—TB9: ANN-S/PG:Serial/parallel printer gateway.Provides a connec- • Jumper selectable by JP31 for resettable or nonresettable tion for a serial or parallel printer. power. ANN-I/O: Driver module. Provides connections to a user-sup- • Operating voltage:24 VDC nominal. plied graphic annunciator. • Maximum available current: 500 mA- appropriate for pow- ACCESSORIES ering four-wire smoke detectors. DP-51050: Optional dress panel. Restricts access to the sys- • Power-limited circuit. tern wiring while allowing access to the membrane switch Refer to the Fire•Lite Device Compatibility Document for listed panel. compatible devices. BB-26: Battery backbox, holds up to two 25 AH batteries and Remote Sync Output-TB2: Remote power supply synchro- CHG-75. nization output,only required for the MS-5UD-3.24 VDC nom- BB-55: Battery backbox,holds up to two 25 AH batteries. inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- TR-CE:Optional trim-ring for semi-flush mounted cabinets. ited circuit. PRN-6F:UL listed printer. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel �O (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC 461,0% operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- kog tion. MS-10UD-7: Ten zone, 24 volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame&post operating instruction sheet). DF-52416:D•07/26/2010—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges • Annunciators 8 This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH Electrical Specifications (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, components may be adversely affected by extreme tempera- 1.0 A ture ranges and humidity. Therefore, it is recommended that • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, this system and its peripherals be installed in an environment 3.90 A with a normal room temperature of 15—27°C/60—80°F. • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. Agency Listings and Approvals • MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, The listings and approvals below apply to the basic MS-5UD-3 2.20 A. and MS-10UD-7 control panels. In some cases, certain mod- • Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- ules or applications may not be listed by certain approval tion,supervised,nonpower-limited agencies, or listing may be in process. Consult factory for lat- est listing status. Cabinet Specifications • UL Listed: File S624 Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x • FM Approved 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x • CSFM:7165-0075:0214 16.65" (42.29 cm.)wide x 5.25" (13.34 cm.) deep. Trim Ring . MEA: MEA:333-07-E (TR-CE):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. NOTE:For ULC-listed models,see DF-60440. Shipping Specifications NFPA Standards Dimensions: The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- -20.00"(50.80 cm.)high lowing NFPA 72 Fire Alarm Systems requirements: —22.5"(57.15 cm.)wide —LOCAL (Automatic, Manual, Waterflow and Sprinkler —8.5"(21.59 cm.)deep. Supervisory). Weight:27 lb(12.20 kg) —AUXILIARY(Automatic, Manual and Waterflow) (requires 4XTMF). —REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTMF is required.) —PROPRIETARY(Automatic,Manual and Waterflow). —CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). —OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. O :.:� ISO9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. CERTIFIED EACIf&QINC 9 MINTING All specifications are subject to change without notice. QUALITY SYSTEMS Made int qr.' For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52416:D•07/26/2010 DF-52004:A1 •F-050 BG-12 Series e<1440 Fit•e•LrTe Alarms Manual Fire Alarm Pull Stations by Honeywell Conventional Initiating Devices General The Fire•Lite BG-12 Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was FIRE designed to meet multiple applications with the installer and • end-user in mind.The BG-12 Series features a variety of mod- els including single-and dual-action versions. The BG-12 Series provides Fire-Lite Alarm Control Panels (FACPs), as well as other manufacturers' controls,with a man- [__DW PUSH INual alarm initiating input signal. Its innovative design, durable PUN construction, and multiple mounting options make the BG-12 Series simple to install,maintain,and operate. Features • Aesthetically pleasing,highly visible design and color. • Attractive contoured shape and light textured finish. - • Meets ADA 5 lb.maximum pull-force. @ Fre LITe ' • Meets UL 38,Standard for Manually Actuated Signaling Boxes. • Easily operated(single-or dual-action), yet designed to pre- vent false alarms when bumped,shaken,or jarred. • PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. Construction • The word "ACTIVATED" appears on top of the handle in • Cover, backplate and operation handle are all molded of bright yellow,further indicating operation of the station. durable polycarbonate material. • Operation handle features white arrows showing basic opera- • Cover features white lettering and trim. tion direction for non-English-speaking persons. • Red color matches System Sensor's popular SpectrAlert® • Braille text included on finger-hold area of operation handle Advance horn/strobe series. and across top of handle. • Multiple hex-and key-lock models available. • U.S. patented hex-lock needs only a quarter-turn to lock/ Operation unlock. The BG-12 manual pull stations provide a textured finger-hold • Station can be opened for inspection and maintenance with- area that includes Braille text.In addition to PUSH IN and PULL out initiating an alarm. DOWN text,there are arrows indicating how to operate the sta- • Product ID label viewable by simply opening the cover; label tion,provided for non-English-speaking people. is made of a durable long-life material. Pushing in and then pulling down on the handle activates the • The words"NORMAL'and"ACTIVATED"are molded into the normally-open alarm switch.Once latched in the down position, plastic adjacent to the alarm switch(located inside). the word"ACTIVATED"appears at the top in bright yellow,with a • Four-position terminal strip molded into backplate. portion of the handle protruding at the bottom as a visible flag. strip combination head 8/32 Resetting the station is simple:insert the key,twist one quarter- • serews Terminal easy includestiPn to PhillipsIcombsting DevicenCircuit captive(IDCturn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The • Terminal screws backed-out at factory and shipped ready to alarm switch can then be reset to its normal(non-alarm)position accept field wiring(up to 12 AWG/3.1 mm2). manually(by hand)or by closing the station's front cover,which • Terminal numbers are molded into the backplate, eliminating automatically resets the switch. the need for labels. • Switch contacts are normally open. • Can be surface-mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single-gang, double-gang,or 4"(10.16 cm)square electrical box. • Backplate is large enough to overlap a single-gang backbox cutout by 1/2"(1.27 cm). • Optional trim ring(BG12TR). • Spanish versions(FUEGO)available(BG-12LSP,BG-12LPSP). 4/O/, • Designed to replace the Fire-Lite legacy BG 10 Series. • Models packaged in attractive, clear plastic (PVC), clam- v�� olt shell-style, Point-of-Purchase packages. Packaging includes V a cutaway dust/paint cover in shape of pull station. O,) DF-52004:A1•04/22/08—Page 1 of 2 Specifications Agency Listings and Approvals PHYSICAL SPECIFICATIONS: The listings and approvals below apply to the BG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies,or listing may be in process.Consult pull station SB-1/0 SB-10 factory for latest listing status. Height 5.5 inches 5.601 inches 5.5 inches • C(UL)US:S711 (13.97 cm) (14.23 cm) (13.97 cm) • FM Approved Width 4.121 inches 4.222 inches 4.121 inches • CSFM:7150-0075:184 (10.47 cm) (10.72 cm) (10.47 cm) • MEA:67-02-E Depth 1.39 inches 1.439 inches 1.375 inches • Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; (3.53 cm) (3.66 cm) (3.49 cm) 6,632,108. 52004dim.tbl ELECTRICAL SPECIFICATIONS: Product Line Information Switch contact ratings:gold-plated;rating 0.25 A @ 30 VAC or BG-12S: Single-action pull station with pigtail connections, hex VDC. lock. ENGINEERING/ARCHITECTURAL SPECIFICATIONS BG-12SL: Same as BG-12 with key lock. • Manual Fire Alarm Stations shall be non-code, with a key- or BG-12: Dual-action pull station with SPST N/O switch, screw hex-operated reset lock in order that they may be tested, and so terminal connections,hex lock. designed that after actual Emergency Operation,they cannot be BG-12L: Same as BG-12 with key lock. restored to normal except by use of a key or hex. An operated BG-12LSP: Same as BG-12L with English/Spanish (FIRE/ station shall automatically condition itself so as to be visually FUEGO)labeling. detected as activated. Manual stations shall be constructed of BG-12LOB: Same as BG-12L with "outdoor use" listing. red colored LEXAN (or polycarbonate equivalent) with clearly Includes outdoor listed backbox,and sealing gasket. visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, BG-12LO: Same as BG-12L with "outdoor use" listing. Does 1.00 inches (2.54 cm) or larger. Stations shall be suitable for not include backbox. surface mounting on matching backbox SB-10 or SB-I/O; or BG-12LA: Same as BG-12L with auxiliary contacts. semi-flush mounting on a standard single-gang,double-gang,or BG-12LPS: Dual-action pull station with pre-signal option. 4"(10.16 cm)square electrical box,and shall be installed within BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/ the limits defined by the Americans with Disabilities Act(ADA)or FUEGO)labeling. per national/local requirements.Manual Stations shall be Under- writers Laboratories listed. SB-10: Surface-mount backbox,metal. NOTE: The words"FIRE/FUEGO"on the BG-12LSP shall appear SB I/O: Surface mount backbox, plastic. (Included with BG on the front of the station in white letters, approximately 3/4" 12L08.) (1.905 cm)high. BG12TR: Optional trim ring for semi-flush mounting. 17003:Keys,set of two.(Included with key-lock pull stations.) 17007:Hex lock,9/64".(Included with hex-lock pull stations.) 4 NOTE: For addressable BG-12LX models, see data sheet DF- 52013. FUEGO/FIRE ! EMPUJE Y • PUSH IN l HALE HACIA ABAJO PULL DOWN ti ME la: Fire•Lite® Alarms, SpectrAlert® Advance, an. -•t Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc.All rights reserv- ,y,orized use of this document is strictly prohibited. 4 C' This document is not intended to be used for installation purposes. ISO9001 We try to keep our product information up-to-date and accurate. y CERT 1 F.EE) We cannot cover all specific applications or anticipate all requirements. MIMING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com k I , ' Page 2 of 2—DF-52004:A1•04/22/08 ,� SYSTEM SENSOR' ,1,1,1,1, . . i t , II " 1 I► ii III III I 11111 I Indoor Selectable- i i Output Horns, �t;t stm = E E Strobes, and . ... . . Horn Strobes for y'iiiI• Wall Applications �,e; System Sensor L-Series audible visible notification products are rich with features guaranteed to cut .t �° 4 " `' a. AL1, , . • : , installation times and maximize profits with lower 111 current draw and modern aesthetics. "` r ' ' Features • Updated Modern Aesthetics The System Sensor L•Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • plastic housings,standard and compact devices,and plain,FIRE, Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95,110,135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt opera• n,and a rotary switch for horn tones with two volume selectio Agency Listings SI SIGNALING N 0 0 it* LISTED APPROVED AL FM approved except 7125-1653:0504 for ALERT models 7135-16530503 3057383,3057072 AVDS865-05.2722/2018•Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. • Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. Strobe The strobe shall be a System Sensor L-Series Model •• listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. • Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. 49 C' dOLO AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 • 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe.Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 O 5 3.1 KHz Temporal High 83 88 88 4t9),% 6 3.1 KHz Temporal Low 76 82 82 + 7 3.1 KHz Non-Temporal High 84 89 89 O 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions �, U1 .f— 3.46' ---- 3.46' —® 485 mm 28 mm 125' - 3.67•--� L55• 88 mm 125' 92 mm (9.1 cm) (39 em) rt01 32 mm I�"F � ,�1 Li ( ' — .mayo0o. 1, ,Q,0,0)°,,,,,;.; 5.27" .rr*■.. 'oaaao444'Wo; 528" L 133.9 mm . taIII 5.27° 00°0aaaoa• (13.7 un) OIC 'III 133.9 mm 'iaiaia• A% 0 aeeaaa =� `4I `/ WAY, Y, I1) o / • A0548-00 A0547-00 A0557-00 • Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70' (11.94 cm) 1,91' _— 4.7" 125' - 4.82'—-- OA c ) 119 mm - 115' 32 mm _ (12.24 cm) 1—(4.1980r m) J (9.18 mm) ' ' I=J 1 eae ir•�yyi4ar :o°oaO000000a' ,0 C 'aaaaoaoaoaa 5.78' _AL O • .wa' 5.67' 0 0 0 0 0 5.67• rat �oaQa�000�oQ, 14.68 cm) (14A cm)1 C41 NII 144 mm a4oa�o�aQa �j tiaiaiairia _ t.La.r.1.a. A0550-00 A0549-00 A0554-OI Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red .P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain ` SWL-P Strobe,White,Plain OA) SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: ^ All-P models have a plain housing(no"FIRE"marking on cover). O All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. t- SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 ©2018 System Sensor. Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to charge without notice.Visitsystemsensacom �� SENSORA for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS865-05.2/22/2018 *Th, SYSTEM SENSOR® t it Photoelectric Smoke Detectors System Sensoriaf"series smoke detectors represent 113) significant advancement in conventional detection. • The P family is founded on three principles:installation ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,P boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the ii line to minimize • nuisance alarms.2-wire ii detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof P detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant inspection.The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the ii protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feat i ',es the initiating loop wiring by providing LED status indication a TY ;r Lector. Agency Listings 110 4 _ MEA MSFM ( t/; LISTED APPNWE➢ I I approved approved NI'us S911 3011446 7272-1653:152 290-01-E 2093 3180932 1i)Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number ,listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V • • Maximum:35V • • Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24V Peak Standby Current 2-wire:100 NA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 53 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20mA@12V,23mA@24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM 02009 System Sensori 3825 Ohio Avenue•St.Charles,IL 60174 Product spedfications subject to change without rwtice.YS corn for SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 current product information.indudingthe latesversion oft AOS-0318007.6/09-A2169 *, Th, SYSTEM SENSOR® -. t - Selectable-Output - Low Frequency Sounder and Low Frequency Sounder I ' • I -R, R I. E R Strobes for Wall E E 4.--... . E Applications • SpectrAlert°Advance audible visible notification products SPECTRAlert are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz±10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: The wall-mount low frequency sounder,and low frequency sounder 135, 150,177,and 185 strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz± 10%and is of a square wave tone.Like the entire SpectrAlert Advance product line they • Mounting plate shorting spring checks wiring continuity before include a variety of features that increase their application versatility device installation while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming ground faults. • Listed for ceiling or wall mounting To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wi•e range of application requirements using field-selectable c.. 4iiii ettings, Agency Listings automatic selection of 12-or 24-volt operation,and .11r. 4 witch for 520 Hz low frequency sounder tones. SIGNALING CI 0 ® MEA ( kL LISTED APPROVED approved 1 1 MVA452-05-E 713516530223 ,- 7125-1653:0224 SpectrAlert Advance Specifications Architect/Engineer Specifications AIM lilt ,Amill1111 General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave.rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135,150,177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking on the housing that reads low frequency sounder'. Low Frequency Sounder • The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for.fire protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3,12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz±10%square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/1s x 21/2-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz±10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inc (142 mm L x 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D 0 Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR,SBBW) (145mmLx120mmWx76mmD) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. SpectrAlert Advance Dimensions F 4.7 in. 2.5 in. P. 14 4.7 in. ► 14-1.3 incl 1111 —---=-=-) 00 0!PMR i�- A lI it It i x II Iv N m u �� rI u n �, u 1 U II z ,, 1, MA I, It • u 6.4 in. " ,, 5.6 in. 0 0 n I, II <I E t \5N ,ii .. NI It / II u N u If kriaLelliml 1 1. Ia.PM,.� , ..a•.I o _ �% Qhs ® _ ----.F., V El`- Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders HR-LF Low Frequency Sounder,Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall,Red VO SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall,Red Notes: 4°,1% "High cd"refers to strobesthatinclude 135,150,177,and 185 candela settings. dibloo, *� SysrEm 3825 Ohio Avenue•St.Charles,IL 60174 ©2015 System Sensor. �� SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Viotsystemsensorcom for current product information,including the latest version of this data sheet. www.systemsensor.com Avos16404.1/15 Q� Scope of Work: Install new fire alarm system in converted residence that will be used a group home. PPLICABLE CODES AND STANDARDS: -FLORIDA FIRE PREVENTION CODE, SIXTH EDITION (2017) Type of Fire Alarm System: Conventional:—x — x_ Addressable: -NFPA 1, FIRE CODE (2015) Is building Sprinklered: No: Yes:_x Fully: x Partially: -NFPA 101, LIFE SAFETY CODE (2015) NFPA 101 Occupancy Type: Day -Care Group Home -FLORIDA BUILDING CODE, SIXTH EDITION (2017) SYSTEM SEQUENCE OF OPERATION - INTERNATIONAL BUILDING CODE (2015) i R R INSTALLING CONTRACTOR INFORMATION: NAME: ALARM CENTRAL INC "DBA" KENTPONIX o i fi STREET: 350 ELDRIDGE AVENUE, SUITE 1 R i CITY: ORANGE PARK, FL 32073 . o o� LICENSE TYPE: EF 4� LICENSE NUMBER: EF0000097 R LICENSE HOLDER: THOMAS KENT INPUT 1►1r�� NAME: Sharella Newsome Group Home PREMISE CONTACT: Sharella Newsome STREET: 948 Hibi;cus Street CITY: Atlantic Beach, FL 32233 PHONE NUMBER: 904-716-0956 FIRE ALARM PERMIT NUMBER: FIRE19-0005 DRAFT/SYSTEM DESIGN CONTACT: ENGINEER OF RECORD INFORMATION: NAME: Jeremy Tuando NAME: PHONE: 904-351-9322 PHONE: EMAIL ADDRESS: Duster8up@yahoo.com EMAIL: CERTIFICATION: STREET: LICENSE #: tyH=oney=well is Main Circuit Board 4XTMF CAC -5X I PDACT-2 I PDACT-2UD 2. Annunciators ANN -80 ANN-RLY 3. Conventional Detection Two -Wire Detector Heads Four -Wire Detector Heads Number of IDC's Used Minus 1 4. Other Devices EOLR-1 Miscellaneous Device 1 Miscellaneous Device 2 Miscellaneous Device 3 Miscellaneous Device 4 Miscellaneous Device 5 5. Notification Appliances NAC 1 NAC 2 r AC 3 AC 4 urrent Draw from TB9 (nonal MS-5UD-3 Battery Calculation Secondary Power Source Requirements D 0 n 0 0 0 0 ❑1 0 1XI Total OFFictc.COPY Fire -Lite Alarms Page 1 10/17/2019 �- 1 1 • 111 B-�© / .111 B- / 1•:111 B -v© / 111 �- /B- 1B- IB- 1�- 1�- 1 1 11.111 B 1 1 � 111 1111111 �- �© B- 1 111111 a-�© / 111111 �- 1 111111 B-�� 1 111111 B� 1 111111 B-�© 1 111111 ®r 1 111111 �-�© / 111111 B� 1 111111 ���© / 111111 �- �© �© 1 111111 �- / 111111 �- / 111111 tB-��© 1 111111 B- .,too Total Alarm ... OFFictc.COPY Fire -Lite Alarms Page 1 10/17/2019 NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit. MS-5UD-3 Control Panel: The output current is within the panel's limitations. Fire -Lite Alarms Page 2 10/17/2019 SPRINKLER NOTES: I . SCOPE OF WORK: DESIGN ANINSTALLATION OF AN AUTOMATIC FIRE SPRINKLER SYSTEM FOR A G OUP HOME (SINGLE-FAMILY DWELLING). 6. PRIOR TO COMMENCEMENT O, WORK, CONTRACTOR SHALL VISIT SITE TO FAMILIARIZE HIM/HERSELF WIT' EXISTING SITE CONDITIONS AND VERIFY THAT RESIDENCE HAS ADEQUATE WATER PRESSURE AND QUALITY OF WATER SUPPLY FOR WET SPRINKLERS SYSTEM. 14. FIRE SPRINKLER CONTRACTOR I IS RESPONSIBLE FOR PROVIDING ENGINEERING, DESIGN, AND INSTALLATION OF THE RESIDENTIAL FIRE SPRINKLER SYSTEM PER NFPA GUIDELINES. CONTRACTOR SHALL PROVIDE PERMITTING, LABOR, AND MATERIALS NECESSARY 10 COMPLETE ALL WORK PERTAINING TO THE FIRE PROTECTION SPRINKLER SYSTEM. 15. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES INCLUDING ELECTRICIANS, PLUMBERS, AND CARPENTERS. FIRE SPRINKLER CONTRACTOR IS RESPONSIBLE FOR FIRE ALARM SYSTEM AND COORDINATION WITH FIRE ALARM SUBCONTRAPTOR. 19. THE SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH 2016 NFPA 13D AND AMEND14ENTS AS ADOPTED BY THE LOCAL JURISDICTION. 20. ONE SET OF OCFA APPROVEC SPRINKLER PLANS WITH HYDRAULIC CALCULATIONS SHALL BE RET. NED AT THE JOB SITE AT ALL TIMES. 21. THE CONTRACTOR SHALL PROTECT EXISTING CONDITIONS AND SHALL PATCH & REPAIR ANY AREA OF DA4GE OR DISRUPTION TO EXISTING CONSTRUCTION. 22. NEW SPRINKLER PIPES SHAL BE LOCATED WITHIN WALLS OR CEILING WHEREVER POSSIBLE. IF Pip MUST BE EXPOSED, THEY SHALL BE ENCLOSED TO CONCEAL PIPI . ENCLOSURE SHALL BE PREPPED AND PAINTED TO MATCH EXISTING DJACENT SURFACES. 23. UNDERGROUND MAINS AND LEAD-IN CONNECTIONS SHALL BE FLUSHED BEFORE CONNECTION IS MADE TO SPRINKLER PIPING, 24. SYSTEMS SHALL BE TESTED AT A MINIMUM OF STREET PRESSURE IN ACCORDANCE WITH NFPA 13D. 25. EXPOSED EXTERIOR RISER VA VES SHALL BE PAINTED OSHA SAFETY RED. FIRE SPRINKLER OR SUPPLY PIPE EXPOSED OR SUSCEPTIBLE TO WET CONDITIONS SHALL BE PAINTED (ANY COLOR) OR OTHERWISE COATED TO INHIBIT CORROSION. STAINLESS STEEL ASSEMBLIES AND PIPING MAY BE LEFT UNPAINTED PROVIDED THAT ANY HOSE CONNECTIONS, VALVES, OR OTHER COMPONENTS OPERATED BY THE FIRE DEPARTMENT ARE PAINTED RED. 26. SPRINKLERS IN SPACES SUBJECT TO TEMPERATURES IN EXCESS OF 100'17 (INCLUDING GARAGES AND EX�ERIOR CLOSETS) MUST BE INTERMEDIATE TEMPERATURE RATED (1757 OR MORE). 27, OUTSIDE PIPING SHALL BE INSULATED AGAINST FREEZING. 28. ALL SPRINKLER PIPING SHALL REMAIN UNCOVERED UNTIL INSPECTED BY THE AUTHORITY HAVING JURISDICTbN. 29. AT FINAL INSPECTION, ALL CLINGS SHALL HAVE ALL PATCHES, REPAIRS, AND FINAL FINISHES COMPLEtED. 50'-0" DIAGRAMMATIC TITS PLAN ;CA(E: 3/32" = 1'-0" GENERAL NOTES: 1. NO CHANGES ARE TO BE MADE TO EXISTING EGRESS PATTERNS, 2. ANY CEILINGS NOT EXPLICITLY LABELED WITH A HEIGHT HAVE A CEILING HEIGHT OF 8'-0", EVI'E ED Jacksonville Fire Preven ' Div A�, " tA %gZz-/, `i OCT 2 2 2019 IEXCEPTIONS EXCEPTIONS AS NOTED SHEET # LIFE SAFETY LEGEND REFLECTED CEILING LEGEND 13'-0" CEILING HEIGHT AS MEASURED CEILING FAN WITH LIGHT TPENDANT LIGHT O L © SURFACE LIGHT FIXTUREMOUNTED & WALL MOUNTED LIGHT EXISTING HVAC CM SUPPLY/RETURN/TRANSFER TO REMAIN 0 EXHAUST FAN MOTOR �} THERMOSTAT UNLESS NOTED OTHERWISE EVI'E ED Jacksonville Fire Preven ' Div A�, " tA %gZz-/, `i OCT 2 2 2019 IEXCEPTIONS EXCEPTIONS AS NOTED SHEET # LIFE SAFETY LEGEND SPRINKLER HEAD 13'-0" CEILING HEIGHT AS MEASURED FROM FINISH FLOOR 36" EXIT WIDTH SINGLE STATION 120V SMOKE SJ ALARM (DETECTOR) WITH BATTERY BACKUP CM BATTERY—POWERED CARBON MONOXIDE ALARM (DETECTOR) 0 FIRE EXTINGUISHER; EXISTING TO r E REMAIN IN ORIGINAL LOCATION UNLESS NOTED OTHERWISE F to -6 AL))it-1 464FouP �- PALL S?AT lam �oIL�'l$TJLL1 Be - cvv►ae V 9791-%y— AOVL PROJECT INFORMATION SCOPE: SCOPE OF PROJECT IS INSTALLATION OF A NEW FIRE SPRINKLER SYSTEM AND ALL RELATED COMPONENTS WITHIN AN EXISTING 1,120 SQUARE FT ONE-STORY WOOD FRAME CONSTRUCTION RESIDENTIAL GROUP HOME. ALL EGRESS ROUTES, DOORS AND WINDOWS ARE EXISTING TO REMAIN. APPLICABLE CODES: A. FLORIDA BUILDING CODE, RESIDENTIAL, 6th EDITION (2017) B. NATIONAL ELECTRICAL CODE, 2014 EDITION C. LIFE SAFETY CODE (NFPA 101) 2015 EDITION D. FLORIDA STATUTE BUILDING CONSTRUCTION STANDARDS, CHAPTER 553 (INCLUDING ANSI AND NFPA REFERENCED STANDARDS) E. FLORIDA FIRE PREVENTION CODE, 5th EDITION ZONING: PER CODE OF ORDINANCES — CITY OF ATLANTIC BEACH, FLORIDA ATTACHMENTS: PROVIDED BY PLATINUM FIRE PROTECTION, INC.: — FIRE SPRINKLER PLAN AND RISER SECTION — HYDRAULIC CALCULATIONS MATERIAL DATA SHEETS s: REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" L___- �Ft'i ���l1 S FpR p`AID Cd�p�'CIO�S �EO.�nr�;E�CS GATE. �p Zti WEO gY� 0p REViE .. 1 LIFE SAFETY PLAN z �01 SCALE: 1/4" NEW FIRE SPRINKLER SYSTEM FOR AN EXISTING GROUP HOME CLIENT Shorello Newsome 948 Hibiscus Street Atlantic Beach, FL 32233 VIA Concepts, LLC 1807 Third Street North Jacksonville Beach, FL 32250 AA26001354 NO. I REVISION/ISSUE I DATE PROPOSED FLOOR PLAN BID DOCUMENTS 00180723CMM AS SHOWN 7-30-18 PROD. N0. DWN BY SCALE DATE, A- 201.