Loading...
193 Beach Ave ACC19-0080 Replace Entry Deck rt' M'% COMMERCIAL PERMIT PERMIT NUMBER , '�_ ACC19-0080 CITY OF ATLANTIC BEACH r 800 SEMINOLE ROAD ISSUED: 11/1/2019 N-...ort > ATLANTIC BEACH. FL 32233 EXPIRES: 4/29/2020 1 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 193 BEACH AVE COMMERCIAL OTHER REPLACE ENTRY DECK $30000.00 COMMERCIAL TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 170314 1004 SHORECREST CONDOMINIUM COMPANY: ADDRESS: CITY: STATE: ZIP: SONSHINE 447 Atlantic Boulevard Atlantic Beach FL 32233 CONSTRUCTION,INC. OWNER: ADDRESS: CITY: STATE: ZIP: SHORECREST CONDOMINIUM PO BOX 330026 ATLANTIC BEACH FL 32233 ASSOCIATION OF JACKSONVILLE INC WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $205-00 Issued Date: 11/1/2019 1 of 2 c"L'r'i� COMMERCIAL PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACHACC19-0080 ISSUED: 11/1/2019 800 SEMINOLE ROAD �` .p.F1 9� V ATLANTIC BEACH, FL 32233 EXPIRES: 4/29/2020 1. BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL:$415.19 Issued Date: 11/1/2019 2 of 2 101.Aivj!'1 City of Atlantic Beach APPLICATION NUMBER 41 �- o Building Department (To be assigned by the Building Department.) r 800 Seminole Road _ i. O j , Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 Q i ;Mr E-mail: building-dept@coab.us Date routed: l t C) City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1r5 6 eC,4. Department review required En No uild j • _ Applicant: N (� CoNMLST dVPlannin• & •• ••' _- — v Tree Administrator Project: R EA FL C(_ . iii •• l•J'.liZ /J /c ublic Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation \ V ` St. Johns River Water Management District Army Corps of Engineers ��� Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: F pproved. ❑Denied. ❑Not applicable (Circle one.) Comments: /)O(-- ) 1 i- -e / -I d %112 VY`r l/ i/- ''Py. 1 rY UILD! PLANNING &ZONING Reviewed by: /'/ Date: /D 16-? TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. nNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 (F_`: Building Permit Application JOB COP Updated l0/9/18 City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY ?-' IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept coab.us 1 GI 3 leach Aver q U 08 Job Address: i'13--/7? 6 All, ,vel ( !,r 134„,e577,-,-; Permit Number: A�C� t V Legal Description //"� RE# Valuation of Work(Replacement Cost)$ [C_ Heated/Cooled SF Non-Icjeated/Cooled • Class of Work: ❑New ❑Addition ❑Alteration �7Repair ❑Move ❑Demo ❑Pool ❑Window/Do ' ll L , • Use of existing/proposed structure(s): ❑Commercial ❑Residential • If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No OCT 8 2019 • Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) ENo Describe in detail the type of work to be performed: ,'(A=L f4.41_,1 df r , -g Derartrr C: '2rtic ;-s-9C Florida Product Approval# for multiple products use product approval form Property Owner Information i . a 'jY)Dre!r' I •I' i le•D.QAddress /.73`14c &acG: wieso7im um ':..► I. . 0.,' State Zip -34,133 Phone q0-t-- Q3 Gael / E-Mail lel o 0 VVo tr I I Ski \e711' C-e [ 41*. coin Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information f Name of Company 5,,011, ('',..-r1J„- Qualifying Agent 131/44) /�f(La�R Address VV'7 {.u,2{,r z__ 6(i1>( kti City &AZ State it Zip 'lZZy Office Phone ?t-( i'3 1-_. 7S‘ 3 Job Site Contact Number Qtr' gj 75-45 State Certification/Registration#05( I1SS'1/f E-Mail 6I4c/ /h(/321fh)A rm,41 i ePyYL Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer OR Exempty Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RE(C• • DING Y UR NOTICE OF COMMENCEMENT. =-''`' ' t wu•4t_ �1�wIt@Qi t-1 ma2 • (Signature of!Owner or Agent) (Signature of Contractor) Signed and sworn to(or affirmed) before me this day of Si:ned and sworn to(or affirmed)before m- • : day of 0c-'C00t r, 20\Cc ,by Pe;n<,04..,,,,1 s,s, r [ 1s.. ..20 _ •._ ,.:, gym-^ C� —t-c....-5-> �+ I NOTARY PUBLIC (Signature of Notary) 4 _STATE OF Ft fire of Notary) -• • Comm#GG212743 / �.r�* Notary Public State of Florida +1 ' • Expires 4/30/2022 '1[ Sharon P Smith Personal) Known OR [ Personally Known OR i ram GG 321448 [ Y I Produced Identificatio ‘0,0 Explrea 05/31/2023 [ )Produced Identification Type of Identification: _ _ _ _ . , Type of Identification: ;l�, City of Atlantic Beach APPLICATION NUMBER t4 9� Building Department (To be assigned by the Building Department.) 800 Seminole Road (\eC _• rt V "MirAtlantic Beach, Florida 32233-5445 1 't _ Phone(904)247-5826 • Fax(904)247-5845 �;t,P E-mail: building-dept@coab.us Date routed: 10 Q I ( City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: R3 h e-AC( Department review required Yes No Applicant. (V (1\DC-;-- �(��� Planning &Zoning' Tree Administrator 1 Project: 1 EA/2--- if•f r Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. enied. ❑Not applicable (Circle one.) Comments:BUILDING Weed rye y PLANNING &ZONING y l�—f 7_(ct Reviewed b Date: f TREE ADMIN. Second Review: as revised. ❑Denied. I 'Not applicable PUBLIC WORKS Comments: J1'APProved / M Gt;.0 1--y PUBLIC UTILITIES f �e G �y o! c Sf(i✓c.l- yr PUBLIC SAFETY Reviewed by: ,/ , Date: 1 0 -3 V' I y FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 , .•r•♦.• 7.. •H. • \ \ 44 \• j oi" 1 i s..1\J. <04 +, to II t Z•••\--- .,, \ . __— • • \Z • 2 ••' \(. • t - t �- •ww t rJ,f!-�O.f�j �_� •' esr, i t.r+n �.t��•' fir` ., ronpr! N i,..n ,� ,- I N, • _11 '� ..••:».r f� r I,JNL's. �. ', 4( a , moo/arta Aaaf A J.' k . .ter• M • w tt t - . ,...`,.77....--.r 1 .e.•n , Y.` tti r« *.viol- n9.r " I. 't •,,- .. �J .t . . , \ , .11 \,. -- %_ _ i _ w _ ___ _i•� ...,• `.'._ \..-a I a.r Ji'i�a -.•r♦+/,•.._..,.n...F'•, • �.. •• ` ` • r.N• �� ..., • \ I • w •� _ _ ,:,':.4I ... •1•• •` •.•••• • Ii/ P •L: r♦, s wv sa.r+rr — ."•� f^..• up,5'•pvN ; • .; r - i✓'• N. '2" • ferns' 5' r. ^ — ` • t: • sn',• .J I �. I'• q) • 1• It ;tt i,M, `•' ` JJ.n• r rNlr r.•. r -• t (• Z �.,,:,.'s 2 ; ' t1-f ; tl I (...7;.;;;;:,..;-_,,,,r,„,,, r .w• i n�.Nlrrn/ 7^.I�. ♦�Pii - 1-.:;;;.. \„,•,..,� If./J• 1 ` • PI IA ' , i 1\ �`• k.• M <.i ! w t ( Ni07M9 -.ttl w.4 ••' ... .t w ^ •s• i (1 .: ��, ;: 1 �: ' , ... �' � —i:..1..........._....t0 N _ • -r' . t. ,I.1 ..�o.�• ' t. , ` .,•t -fir- ..• . . 1 fSfl , • ••t.....•• '..♦ 'aim �..._---- \-7*- is ��:,,--f:--= +113el5 `------.--..-,__— (1-V3 i ! ins ,' •t,,:� ;�'. J C t w\ .. „:, , ,%.., ��� . , Q., 13.441 • �..pis1.- 1 .X' tt 1 < 1 LN��� -canna ._ caw..... __.... ` ,s r 1 Revision Request/Correction to Comments **ALL INFORMATION �t='y`ir�„ HIGHLIGHTED IN S ` ' r „ City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: Aeo.i9 ooac ❑ Revision to Issued Permit OR Corrections to Comments Date: Z.V/7 Project Address: I A ,?)(: Q Contractor/Contact Name: 6X../£4)j11l� .Nth 4, "Al-G,V4 Com — .1,..---AX- Contact ,-t1 -Contact Phone: ge) t,6' 7c.9 • • Email: , 111h ,BQi`�4-l/124 k-Z, , c-o-ifh • RECEIVED Description of Proposed Revision/Corrections: ii ,< ' /1 0CT 91 2Q19 Building Department t City of Atlantic, beach, t-L_ I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • ill proposed revision/corrections add additional square footage to original submittal? No ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? rNo ❑*yes (additional increase in building value:$ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments Department Review Required: Building - arning&Zoning Reviewed By Tree Administrator Public Works Public Utilities I o 3 / ( GI Public Safety Date Fire Services Updated 10/17/18 HOW/h'6 SURVEY OF _ _ MAP S .. ./ trrt M//raa.' 7....."......t/.,,r„r„/,4,14 S H 0 R E C R E S T 04,4,4' n..vrr,/we/s,. //M•r/Al!(r ,'1//I r//I/!.4,1 ri'//N:/!/r/ !//WI.4,de,r ,/rhr/t. .,,,,A,,144,-.,: ,rr„!.t /lit.; //11.400,/ — �'t! - ri rt.er 4.7,,,/ Y,,,t/!!!f,„!,/[, t/tr.,rv,//,'t"a-4.tnr i,iti:;.r•:. -� ./.1".../:::,,/!,./ n.-..•tr, „i!/.rt,r4,t44,17C,41071 cllr..n,l.-ra ti I I �CONOOMINtUM • :flirt,!!!/r,rrr.,�!!•+• �f �iT t DUVAL COUNTY FLORIDA `0 4�. .II' • re-:- --, /3.r: s,bc-c Dfsr ca.cz.r..�r..*� If t v t �FSIPfstSJO EXHIBIT "q” ` tis' .+,•'� . SURVEY AND PLOT PLAN' l;. j�-., • / ��'' ie. =::rte•.------ 4 —fECO�r/� " (r/�!/r) . .. STA'EET — r it` ..•..r • - ---- --- - •. ',-� -�r,W�G+rt •t-'•-TF ( _'-%J ate'r 1 1. 11 Vit =c. :r` .. yam l r>:., ' •-,- .: ;• _-` .. 1.1 -,-.:t..-- :',..11.t-::0;••••;;-"4 .1•.I'•7.-.7. ...7=,,......,‘.72...r1 i -i!. �r !i!.i•:�i J`C.�_ - .. :.1 IffSS• 1 li•11 • Q J;• u� r_r i `'. r.,•.:•'. ' t; ..•..Yc...'y111' <'1 .k' �.,,"... 1,17-...-L-"•.‘,2', Z,.,--2:41 1 ..u- '\9 t \' % to \` t.r lr/ ,l..Fr I. , I Is.\. ++4- r : .''.i t...l.i�,..J ...J ‘.1 I� r:a- _ ✓.r ,tJ it rc: 1 7 '•.?•� r•.l.•r•.,r_.r ...+s•+ F....Ir...., .1�..�1.....e-� �. . 1 �'.1 t :::•,' .•.•I t Is ......_, ,......._............., • (� t•• :�. •4,4,4,,,,,,•. •r!/_7 �_ "; lw ...o.w r. �..,.t,.."'t'•t trtr. !.r`...�.. t, d—_ �a ` .. V` . ` Lr 1 1 1 1 1 1 1 lu i b c i.'- ..moo \ rN ..: • • • ti. A .. j-•'••:`'. '•q • a/' f" �l.i.rr, ri _tl�, h : `1C'. •, V "\ Y ,�� 1� :I pY IA / i, .c'7-` • �.. •.•••,,,,......., �� .rr- �!'»'" L` 9l X'`� i1 { ? Y, "i JF j ] .� P s� , -1.'-1, �'::..:. � _«`i; �� -- ��.:;r: .,:/..:;•.„ +.,. .5:•-•"1:.,,,,,,,,.9,S7../,'1=•••,--'� ri ..I I =7••• •�.r 1\ - k \ I GT ti ',li- ,_."f-1_.�J .1•:- `-'f=\\ tr� P ..• - ._•.I;,,, -...-- „,,,721%•.'-‘,•,7•71-(.:71”. • '--. .••i?r_ r • - • Cr) r`.. -•- ': •:1 �� ,--- =��•.v lr i.w rr ' , . + t^ I V rrr`�'. �i'�* :4 ' r''� _ 1' .i` x11 .:_ ..:f:':-:-a''=.:*-. r_. . .,1:5:..,: .1t. r • �' ; 131.DG. # , ,,,/000 SHORECREST WpQp UNfl1 41" 2 Po•TIo_/BL1LGoNY PATto -- uN4 VT Cr 5 U►_)i T. 2 CONDOMINIUM- 74.z ONDOMINIUM= r� I,`;I `.t• K—'� DUVAL COUNTY � - �.7 Q T33' • " FLORIDA r tea. • . .iii _ • "{ los' ,` o K EXHIBIT " B-3 " --r I tts' LR/DR • '� UNIT 5 FLOOR PLAN - UNITS 5 AND. 6 I • cc PFZIVdTE moo o BUILDING 2 = z., 79• •.' 48• P.C."Tto/B�LGoNY - I s' t0 to#' 09•� °�' Ds' U t-1.1"1" az as GENTCA! NOTES :, �., l01' 1. THE BOUNDARIES OF EACH UNIT SHALL FE DETEIC.IHED . h AS FOLLOWS: - a) F1DRI2DATALBOUDARIES. THE UPPER MD LCA/ZR 3p°� as' BOUIDARIESSHALL BE THE FOItOc:1N:BOUND/RIES Y f O• • B R PERE If�1L INTERSECTION DETAILS ION WITH THE . CJ' •0 ` 1 X0.4• (1) IPPA BDNNCAIS THE IS OF THE p WPOIOST UNDECORATED FIN FINISHED CEILING. s B • (II) -MI DOIACNART 1S THE PLATE Of THE MEI-,- 0 4 MOST UNDECORATED FINISHED FLOOR. U IT.L' /7 4' • b) PERNETRICAL BOUNDARIES. THE VERTICAL PLANES J ! 9.0' f..., OF TIE UNDECORATED FINISHED INTERIOR OF iK • Z. f / 1 ... WALLS DOUDINR THE UNIT EXTENDED TO INTER- . =�11. • o• SECTIONS VOW EACH OTHER AND WITH THE UPPER ' AND LOWER IDUDARIES. { ►I o K ti . ... • ..f q• - j.L OMITS S A G EACH MIT ATTICS WITH FINISHED C.1333.4' ti -ADEQUATE LIVING CROITI NS. W LR/OR D D , pa UNIT 6 ':z.s • o 0 ti -i> = 0 . Q �Z$• °`. 1.6'I__ >10., C"'., L ' 111111rs: J o e o To.. 1--1 `....'D TT s r CD . t s TT��77 p.s o >.: I,to °..• "*.% To - ' N , .s' LS' pt' /t' �c.s'a .I i BR ...4vi 1.114. .104. _ a' n o .. • 4.t' t.5' .4 !.0' P: S.0' 1:!: r 1. '''a,� Q [_V '� °P • /2�V/5 : SdPT. /5, /969 b s CX assetI, Inc • - SECOND FLOOR PLAN SHEET 5 OF At IM II.IMCI •l.M•IC.,LICMHICII•L.M•fL.MWI11 • _ 11.CIMIY1111.11.I.I.CII•.I.Ill..Il•.11.Ila.•1.0..81114 PI1.1011 • - SHORECRES.T =CONDOMINIUM= ' DUVAL COUNTY FLORIDA EXHIBIT IA-I ' • 1 i I • LEGAL DESCRIPTION .- LEGAL DESCRIPTION • A PARCEL OF LAND LYING IN SECTION 16, TOWNSHIP 2 SOUTH, RANGE 29 EAST, DUVAL COUNTY , FLORIDA, BEING PARTLY COMPRISED OF LOT 6 AND THE NORTHERLY 25 FEET OF LOT 5, BLOCK 32, SUBDIVISION "A", ATLANTIC BEACH, ACCORDING TO PLAT THEREOF RECORDED IN PLAT BOOK 5, PAGE 69, OF THE CURRENT PUBLIC RECORDS OF SAID COUNTY, AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTION OF THE EASTERLY LINE OF BEACH AVENUE (A 40 FOOT RIGHT OF WAY) WITH THE SOUTHERLY LINE OF SECOND STREET (A _ .40 FOOT RIGHT OF WAY) ; RUN THENCE ALONG SAID SOUTHERLY LINE OF SECOND - STREET (ALSO BEING THE NORTHERLY LINE OF SAID LOT 5) AND THE EASTERLY PROLONGATION THEREOF, NORTH 83° 09' 45" EAST, A DISTANCE OF 245.55 FEET . TO A POINT IN THE EROSION CONTROL LINE AS SHOWN ON PLAT RECORDED IN PLAT BOOK 35, PAGES 59, 59A, AND 59 B, CURRENT PUBLIC RECORDS; RUN THENCE .:. SOUTH 06° 50' 45" EAST, ALONG SAID EROSION CONTROL LINE, A DISTANCE OF . 74. 98 FEET; RUN THENCE SOUTH 83° 09' 45" WEST, A DISTANCE OF 247.44 FEET TO THE AFOREMENTIONED EASTERLY LINE OF BEACH AVENUE; THENCE NORTH 05° 24' 15" WEST, ALONG SAID EASTERLY LINE, A DISTANCE OF 75.00 FEET TO THE • :.: 'POINT OF BEGINNING. cn • _ s '' L A NEP S THUS DESCRIBED CONTAIN 0.424 ACRES, MORE OR LESS. . F t' t a A�. may: • I . • • bassett &bassett, inc SHEET 2 OF 12 Hi .MCIMC{ll•1.M..0 I,ICIf.I.M..L .,1...1..,.1..,..., .1..1....1. 111 . . 11 GENERAL NOTES & DESIGN CRITERIA: CODES: W FLORIDA BUILDING CODE EXISTING BUILDING 6th EDITION (2017), ATTIC, NDS, AWPA & APA, ACI -318, ASCE 7-10, AISC, AWS, AISI, ANSI, AITC. z CLASSIFICATION OF WORK: REPAIR PER CHAPTER 5, SECTION 502 & CHAPTER 6 ALTERATION - LEVEL 1 PER CHAPTER 5, SECTION 503 & CHAPTER 7 DESIGN LIMITATIONS: W THIS DESIGN AND THESE DRAWINGS ARE LIMITED TO ONLY THE STRUCTURAL ASPECTS OF THE APPLICABLE CODES AS THEY PERTAIN TO THE REPLACEMENT OF THE SECOND FLOOR PORCH AND EXTERIOR STAIR. o LOADS: GRAVITY: N% DECKS 60 PSF STAIRS & SIDEWALKS: 100 PSF WIND LOAD: o BASIC WIND SPEED, V (ULTIMATE) 130 MPH .RISK CATEGORY 2 EXPOSURE CATEGORY D .INTERNAL PRESSURE COEFFICIENT ±0.18 (ENCLOSED BLDG.) PRESSURES ON COMPONENTS & CLADDING N/A SOILS INFORMATION: .PRESUMPTIVE NET SOIL BEARING CAPACITY 2000 PSF (ASSUMED) CONCRETE: ALL CONCRETE SHALL BE NORMAL WEIGHT w/ A 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI. REINFORCING STEEL ASTM A615, Grade 60 UNLESS OTHERWISE SHOWN ON DRAWINGS, MINIMUM COVER FOR REINFORCING SHALL BE THE FOLLOWING: CONCRETE EXPOSED TO EARTH OR WEATHER.- #6 EATHER:#6 THRU #18 BARS: 2" #5 BAR, W31 OR D31 WIRE AND SMALLER: 1 1/2" A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD TESTING INCLUDING SLUMP TESTS AND CYLINDER BREAKS TO ENSURE CONFORMANCE WITH PLANS & SPECIFICATIONS (IF PROVIDED). SUBMIT REPORTS FOR REVIEW AND APPROVAL. MINIMUM FREQUENCY OF TESTING FOR EACH CLASS OF CONCRETE IS ONCE EACH DAY. ALL REINFORCING SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES IN COMFORMANCE WITH ACI 315 DURING PLACEMENT OF CONCRETE. PROVIDE 1/4" PRE -MOLDED EXPANSION JOINT MATERIAL WHERE SLAB ON GRADE ABUTS COLUMNS & GRADE BEAMS, AND 1/2" JOINT MATERIAL AT WALLS OR OTHER VERTICAL SURFACES UNLESS OTHERWISE SHOWN OR NOTED. MISCELLANEOUS STEEL: S.S. ANGLES, PLATES &.MISC. STEEL S.S. STRUCTURAL BOLTS S.S. WASHERS S.S. NUTS S.S. WELDED STUDS WELDS ASTM A240 STAINLESS STEEL ASTM F593F, TYPE 316L STAINLESS STEEL, Fy=30 K ASME B18.2.1, TYPE 316L STAINLESS STEEL ASTM F594, TYPE 316L STAINLESS STEEL ASTM A493, Grade 1010 THRU 1020, TYPE 316L STAII AWS, SERIES E70XX, LOW HYRDROGEN NOTE. ALL STAINLESS STEEL TO BE DOMESTIC STAINLESS STEEL. POST -INSTALLED ANCHORS & EPDXY: EXPANSION ANCHORS (U.O,N.) SIMPSON "TITEN HD" (FL15730.7) OR ENGINEER APPROVED EQUAL .EPDXY SIMPSON "SET -XP" (FL15730.6) OR ENGINEER APPROVED EQUAL CONCRETE/MASONRY SCREWS 1/4" TAPCON w/ HEX WASHER HEAD U.O.N NAILS: USE DEFORMED (SPIRAL) SHANKS OR ANNULAR (RING) SHANK NAILS IN HIGH MOISTURE ENVIRONMENTS. OVERHEAD AND/OR CONSTANT TENSION POST -INSTALLED ANCHOR INSTALLATIONS NOT SHOWN THE DRAWINGS SHALL NOT BE PERMITTED UNLESS EACH CONDITION IS REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD. INSTALL ANCHORS TO MEET THE REQUIREMENTS INDICATED IN THE DRAWINGS AND THE MANUFACTURER'S RECOMMENDATIONS. LOCATE BY NON-DESTRUCTIVE MEANS, AND AVOID ALL EXISTING REINFORCEMENT PRIOR TO INSTALLATION OF ANCHORS. IF EXISTING REINFORCING LAYOUT PROHIBITS THE INSTALLATION OF ANCHORS AS INDICATED IN THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY. INSTALL MASONRY ANCHORS IN SOLID MASONRY OR IN HOLLOW MASONRY THAT HAS BEEN GROUTED SOLID AT LEAST ONE COURSE ABOVE, ONE COURSE BELOW, AND ONE COURSE ON EACH SIDE OF THE ANCHOR. WOOD: LUMBER: WOOD CONSTRUCTION IN ACCORDANCE WITH CHAPTER 23 OF THE FLORIDA BUILDING CODE, ALL LUMBER: SOUTHERN YELLOW PINE, MC19, No. 2 ENGINEERED WOOD PRODUCTS: GLU-LAM 1.8E (FL1630.3) PROVIDE MOISTURE PROTECTION FOR EXTERIOR USE. FASTENERS: PER TABLE 2306.1 FBC U.O.N. INSTALL PER MANUFACTURER'S INSTRUCTIONS. MANUFACTURER OF GUN NAILS MUST MEET COMMON NAIL SPECIFICATIONS FOR FRAMING APPLICATIONS. FRAMING ANCHORS: NOTED ON PLANS BY "SIMPSON" w/ "ZMAX" COATING OR ENGINEER APPROVED EQUAL. MISCELLANEOUS NOTES: A. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING THAT IS REQUIRED DURING CONSTRUCTION TO KEEP THE STRUCTURE SAFE & PLUMB UNTIL THE ENTIRE STRUCTURE IS ERECTED. BRACING SHOWN ON DRAWINGS IS FOR THE COMPLETED STRUCTURE ONLY. B. ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY MECHANICAL ELECTRICAL, AND PLUMBING EQUIPMENT SHALL BE VERIFIED WITH EQUIPMENT PURCHASED BEFORE PROCEEDING WITH STRUCTURAL WORK. C. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. D. ALL LUMBER SHALL BE IDENTIFIED BY THE GRADEMARK OF AN APPROVED LUMBER GRADING OR INSPECTION BUREAU OR AGENCY. E. ALL TREATED WOOD SHALL BEAR AN APPROVED AWPB QUALITY MARK OR THAT OF AN APPROVED INDEPENDENT INSPECTION AGENCY. RENOVATION NOTES: A. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS & CONDITIONS OF EXISTING STRUCTURE & SITE THAT ARE AFFECTED BY NEW WORK. B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS & REPORT ANY STRUCTURE & SITE DEVIATIONS & DISCREPANCIES IMMEDIATELY TO THE ENGINEER. STRUCTURE MAINTENANCE STATEMENT: ALL STRUCTURES REQUIRE PERIODIC MAINTENANCE TO EXTEND LIFESPAN AND TO ENSURE STRUCTURAL INTEGRITY FROM EXPOSURE TO THE ENVIRONMENT. A PLANNED PROGRAM OF MAINTENANCE SHALL BE ESTABLISHED BY THE STRUCTURE OWNER. THIS PROGRAM SHALL INCLUDE SUCH ITEMS SUCH AS BUT NOT LIMITED TO PAINTING OF STRUCTURAL STEEL, PROTECTIVE COATING FOR CONCRETE, SEALANTS, CAULKED JOINTS, CONTROL JOINTS, SPALLS AND CRACKS IN CONCRETE, AND PRESSURE WASHING OF EXPOSED STRUCTURAL ELEMENTS EXPOSED TO A SALT ENVIRONMENT OR OTHER HARSH CHEMICALS, 9 VICINITY MAP LOCATION MAP D OFFICE Copy Approved By Permit Desk Building Department City of Atlantic Beach, FL MICHAEL S. KOVACS, P.E. STRU9j®TjjqhL,ENGINEER d'NG,•' G NSF.•;4�e 7233 ' STAT plU® A���°o°o Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC Ell W z tM z Z w vE CN N W �0�z o L 0 N% wCL XO awLl O WAMJ ... o Q z Q F `u°i w F-- La N o 00 F o v `Z w m M <= i- > :,I .. S V)uj C.) r' O J M oY�z Z�� O tx aF Boz F "to O a W z °' a N 0 Zm o 4fly 3X 5-FXo zLLF W ... s w ' v a L N ?(0_j Z� 0-ryu- 8 P'V P_ 21 O N z�8 V �N 21U S W e s t— J a Q4z UF=0 ♦/� F v�w oF- F ow N 0�z MICHAEL S. KOVACS, P.E. STRU9j®TjjqhL,ENGINEER d'NG,•' G NSF.•;4�e 7233 ' STAT plU® A���°o°o Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC Ell C tM z Z CN N W M o L W z cr o Q ® > LL � CL F-- r W Q W WL v `Z W m M LJ L) C.) r' W r-- z O tx Q CL O F— vj MICHAEL S. KOVACS, P.E. STRU9j®TjjqhL,ENGINEER d'NG,•' G NSF.•;4�e 7233 ' STAT plU® A���°o°o Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC Ell > Y n x J A n .LJ x i x A x s z z Aj z z z n n_ L Y J J I J MATCH EXISTING 111TEW SECOND FLOOR PORCH SUPPORT LOCATION PLAN SCALE. 1/2" = V-0" PLAN NOTES: 1. SEE SHEET S-0 FOR GENERAL NOTES & DESIGN CRITERIA. 2. CONTRACTOR TO FIELD VERIFY DIMENSIONS & EXISTING CONDITIONS PRIOR TO COMMENCING CONSTRUCTION. JG BRICK kLK MICHAEL S. KOVACS, P.E. STRUCT RRffNGlNEER ow N 72 ST• (u .. Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-1 w z U X CN u.i w co M ., o w O 0 ... Qz Z> N af ham} � ® aJ s •0. < z O� YZ Z a -a a `_ < wco a— F-0¢ ' w 0 WZ, L-1z CA � N 4 a m 0 0 Z a >- mocha s�sn a0 �x— ♦/�//�� V♦ ami LD Ws sa 0 A z loo z � vii V Qz— .0 J i5p O co Z -p= ww�? - CF MICHAEL S. KOVACS, P.E. STRUCT RRffNGlNEER ow N 72 ST• (u .. Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-1 CN u.i co :: < • ui •0. • UJ CL . a MICHAEL S. KOVACS, P.E. STRUCT RRffNGlNEER ow N 72 ST• (u .. Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-1 4 R P.T. 2X12 STRINGER. P.T. (2)-2X12 STRINGER. P.T. 5/4 DECKING 24'-10" L 1 V-11 "+ 17'-6y2"+ (5 1/8x12" EXTERIOR GRADE GLU-LAM BEAM) (5 1/8x12" EXTERIOR GRADE GLU-LAM BEAM) (5 1/8x12" EXTERIOR GRADE GLU-LAM BEAM) zmm *&, , ! D M.Ak SCALE: 1/2" = V-0" PLAN NOTES: 1. SEE SHEETS -0 FOR GEN\IERAL NOTES & DESIGN CRITERIA. 2. CONTRACTOR TO FIELD VERIFY DIMENSIONS & EXISTING CONDITIONS PRIOR TO COMMENCING CONSTRUCTION, P.T. 2x8 TYP. @ LANDING w/ SIMPSON "LUS28" EA. END (FL PROD. APP #FL10655) P.T. (2)-2x8 CENTERED UNDERNEATH STAIR STRINGER W/ SIMPSON "LUS28-2" EA. END (FL PROD. APP #FL10655) P.T. 2X12 STRINGER. P.T. (2)-2X12 STRINGER. APSON "LSC" )JUSTABLE STRINGER )NNECTOR TYP. - PROD. APP. #10865) MICHAEL S. KOVACS, P.E. STR-ft"fi9M I;IEER 4,,'®®�'� opo® 729 w ° M STA f 4f l0NA%_ Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-2 x W Z F—M z U3�ZX W N W cy') z .Jw m W a CL W Ll a w z U Qto z Lu Z¢W0. Jw uiZ Q LJL �< � W �¢ Q Q 9W WZ za of Y Z 0.1 a '' 0 F W0 �o< (bco® 0�� z � mQo z — Fra dv tl) �� s�o a 3x< =a W ... W 4 N = �J ,z a a ®Q� LO Z�f?� q V �J eOs t- J a Q.¢Z :mn Q W cn uw? MICHAEL S. KOVACS, P.E. STR-ft"fi9M I;IEER 4,,'®®�'� opo® 729 w ° M STA f 4f l0NA%_ Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-2 m F—M z Z N cy') CLij W O z V z Lu O Q LJL W i) Q Q W m m u0(v3—)F— cy) CL W z C:) Q MICHAEL S. KOVACS, P.E. STR-ft"fi9M I;IEER 4,,'®®�'� opo® 729 w ° M STA f 4f l0NA%_ Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-2 I NEW PORCH SECTION SCALE: 1" = 1'-0" S13 WOOD BEAM SEE PLAN (2)-5/8"0 LAG BOLTS HOT DIPPED GALVANIZED BEAM SADDLE SEE DIS -4 NEW PORCH SECTION 2 SCALE: 1" = 1'-0" S-3 3ELOW JL FRAMING WOOD BEAM SEE PLAN T. 2x4xCONT. w/ i -1 0d NAILS @ WDRAIL POST -. 2x2 PICKETS 4" o.c. MAX. (1)-10d NAIL TOP 3OTTOM -. 4x4 POST AT > o.c. MAX. E PLAN 2x4xCONT. w/ .1 Od NAILS @ NDRAIL POST )OD BEAM PLAN 5/8"0 THRU BOLTS w/ ,SHER & NUTS. POST PLAN PSON "ABU66Z" w/ 0 THREADED ROD 'CONC.EMBED SIMPSON "ABU44Z" X4 POST — EXISTING DRIVEWAY NEW PORCH POST SECTION 3 SCALE: 1" = 1'-0" S-3 MICHAEL S. KOVACS, P.E. STRYFaT,YN\LENGINEER <7233 s m s r V '• �TATE`fl 3 : • t 0 R,®•••�eo� Cf^m t r,,z %A Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-3 af w �.M z Z N J �U J www L LuaX M .. awL o a0Q-i Z W 0 J F in w Q = Q O oO m m = �W/ 1L M a S t1 omi /r w :121> O Z C:) o� < YZ Z do 0 a�F �coN QF �0Zi W co 0 Wti > U' ", —:f cm Q o ->< - Q d � x of s�o F <mm W N aIa w a�w 'D n z cn c. _ e•s J a¢0 0 F o� F- 0 w w �ofz MICHAEL S. KOVACS, P.E. STRYFaT,YN\LENGINEER <7233 s m s r V '• �TATE`fl 3 : • t 0 R,®•••�eo� Cf^m t r,,z %A Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-3 C �.M z Z N W C M M0 L o a0Q-i Z W 0 J W Q = Q i)U m m = �W/ 1L M LV z C:) W 0 � Q MICHAEL S. KOVACS, P.E. STRYFaT,YN\LENGINEER <7233 s m s r V '• �TATE`fl 3 : • t 0 R,®•••�eo� Cf^m t r,,z %A Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-3 L6X4X3/8X1'-6 1/2" w, 5/8"0 THRU-BOLT w/ WASHER & NUT TO I ABOVE AND (3)-5/16' LAG SCREWS INTO EXISTING FLOOR JC Z Q X � W U DBL. 2X LEDGER SEE 2/S-3 L6X4X3/8X2'-2" (LLV) CUT & REMOVE HORIZ. LEG AT EXTEI OF WALL & EXISTING BLOCKING BETWEEN NEW 2X JOIST - SEE I 0 ENLARGED DETAIL A S-4 SCALE: 1 1/2" = V-0" 5" NOTE: ALL STEEL AND FASTENERS TO BE STAINLESS STEEL. -iRU-BOLTS RS & NUTS E FAR SIDE 1/4X0'-6 3/8" i� L3X3X1/4 WOOD BEAM SADDLE DETAIL EXISTING GIRDER TRUSS SOLID 2X WOOD BLOCKING BETWEEN EXISTING JOIST AND STEEL PLATE AND BETWEEN STEEL PLATE AND EXISTING GIRDER TRUSS PL3/8x6"x2'-8" EXISTING 2X BLOCKING IN BETWEEN JOIST, CUT SLOTS THRU BLOCKING AS REQUIRED NEW P.T. WOOD BEAM SEE PLAN PL%"x6"x2'-8" w/ (2)-5/8"0 THRU-BOLTS @ NEW BEAM 5%" 1 1� __T SCALE: 3" = 1'-0" 77 x5"x1'-0" 'LATE TYP. L6X4X.II/8X1'-6 1/2" w/ 5/8"0 THRU-BOLT w/ WASHER & NUT TO L ABOVE AND (3)-5/16"! LAG SCREWS INTO EXISTING FLOOR JOI Z Q U� X � W� U DBL. 2)( LEDGER SEE 2/S-3 L6X4X;1/8X2'-2" (LLV) CUT & REMOVE HORIZ. LEG AT EXTE'. OF WALL & EXISTING BLOCKING BETWEEN NEW 2;K JOIST - SEE I ENLARGED DETAIL B S-4 SCALE: 1 1/2" = V-0" NOTE: ALL S T -EEL AND FASTENERS TO BE STAIN ILESS STEEL. 3/4" CHAMFER TYP 3/8" SIDE PLATE PL1/2"X8"X0'-10" v (4)-5/8" Ox5 HEAD STUDS L6X4X%X1'-6 (LLH) AND VERTICAL LEG TURNED UP w/ (2)-5/8"0 THRU-BOLTS THROUGH EXISTING GIRDER TRUSS AND FLOOR JOIST, EXISTING GIRDER TRUSS EXISTING GIRDER FLOOR JOIST L6X4X3/8X1'-6 (LLH) AND VERTICAL LEG TURNED DOWN. CUT & REMOVE HORIZ. LEG AT EXTERIOR OF WALL & EXISTING BLOCKING BETWEEN JOISTS ;2)-5/8"O THRU-BOLTS @ VEW BEAM 1y4 . 5% 1y4'. 2" 4" 2" 8" BRACKET BASE ATTACHMENT E SCALE: 3" = V-0" S-4 RU -BOLTS 3&NUTS L6X4X3/8X2'-3 w/ (2) 5/8"0 THRU-BOLT w/ WASHER & NUT TO L ABOVE AND (3)-5/16" LAG SCREWS INTO EXISTING FLOOR JO Z Q XZ) W 2i U DBL. 2X LEDGER SEE 2/S-3 L6X4X3/8X2'-2" (LLV) CUT & REMOVE HORIZ, LEG AT EXTEI OF WALL & EXISTING BLOCKING BETWEEN NEW 2X JOIST - SEE f (2)-5/8"0 THRU-BOLT NEW BEAM ENLARGED DETAIL S-4 SCALE: 1 1/2" = V-0" MICHAEL S. KOVACS, P.E. STRUCTURAL ENGINEER 000loi9$G0ilp19 NN m��G:•°°(;ENS .0 a ST/Cq� ro ONM- Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-4 x w z �.... z Z SZX M N JU J �wz QLLI � waa W .% awu- o ao� a J 0w Q Z Qw N M o Wo o Lf� <? Q m ~¢�`n� s M � w o -' z W C) Ad Y z ao -Z-, <W i nam a o F 0 GoN W Q .. zp'a n o 0 z:3m �cw°sa avcai x¢ cl)Seo W . . . i W Q cn a : UiN = N L 0) ■` n D ZQU � h ■ Vi J 0 2gU e e S W a a$z 0 V♦� � p Moi oww c�X? MICHAEL S. KOVACS, P.E. STRUCTURAL ENGINEER 000loi9$G0ilp19 NN m��G:•°°(;ENS .0 a ST/Cq� ro ONM- Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-4 �.... z Z M N Lu cy') QLLI � Q W z ao� � J � Q W W♦ U U Lf� V�. j W W m Q m M W z �o i CL F z Q MICHAEL S. KOVACS, P.E. STRUCTURAL ENGINEER 000loi9$G0ilp19 NN m��G:•°°(;ENS .0 a ST/Cq� ro ONM- Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-4 (2)-5/8"0 THRU-BOLT w/ WASHERS & NUT1 (2)-SIMPSON "LSC' AI STRINGER CONNECT STAIR ELEVATION A S-5 SCALE: 1/2" = V-0" NOTES.- 1. OTES:1. STAIR STRINGER GEOMETRY TO BE IN CONFORMANCE WITH SECTION 101 1.5.2 OF THE FLORIDA BUILDING CODE. 2 PROVIDE GRASPABLE HANDRAIL IN ACCORDANCE WITH SECTION 1014.3 OF THE FLORIDA BUILDING CODE, 3. STAIR LANDING IS REQUIRED IN ACCORDANCE WITH SECTION 1011.8 OF THE FLORIDA BUILDING CODE. 4X4 POST SIMPSON "ABU44Z w/ 5/8"0 THREADED ROD & 3" EPDXY EMBED INTO EXISTING CONC. SLAB. DO NOT OVERDRILL EXISTING CONC. SLAB MICHAEL S. KOVACS, P.E. SIC," Mi "jpGINEER S. IVT"••. �d `y N 723 • b Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-5 Of w z �ZX t...�M Z J SSU Lu W wz N wac awa 0 0 .. p LJJ C.�Zjo z cr Q z Z Jin aw wZ a a fY U w ° w �< 5 m w 0 0 2 YQ Z°o z a`;'F W _. < o W 0 zrna z Z moC' ® Dana an°~_ Seo 3xaU =QP amx L` a W s w U N I1�w ?� a C'4 w 0 N h � S SSU W t-- J �QQZ F 0 X F wwp :20 0 w 02 MICHAEL S. KOVACS, P.E. SIC," Mi "jpGINEER S. IVT"••. �d `y N 723 • b Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-5 C t...�M Z Z W N MQ � p LJJ C.�Zjo z cr Q LL W U w U <C W m m V ��W V M To-, W l-- z 0 ac MICHAEL S. KOVACS, P.E. SIC," Mi "jpGINEER S. IVT"••. �d `y N 723 • b Reg. No. 72339 PROJECT NO. 19013 ISSUE DATE: 10/03/19 REVISIONS: DRAWN BY: LAC CHECKED BY: DJC S-5