Loading...
1596 Maritime Oak Dr ROOF19-0078 Metal r,�„:-1,....,,,-,),,„, ROOF NON SHINGLE PERMIT PERMIT NUMBER (4'C*:: ',� ROOF19-0078 �, , jCITY OF ATLANTIC BEACHISSUED: 11/5/2019 - 800 SEMINOLE ROAD ATLANTIC BEACH. FL 32233 EXPIRES: 5/3/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1596 MARITIME OAK DR ROOF NON SHINGLE METAL ROOF $18877.00 TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 169505 1975 ATLANTIC BEACH COUNTRY CLUB UNIT 02 COMPANY: ADDRESS: CITY: STATE: ZIP: CACHE CO LLC 633 W 46TH ST JACKSONVILLE FL 32208 OWNER: ADDRESS: CITY: ' STATE: ZIP: ZALUPSKI CHRISTOPHER E WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS (Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $145.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $72.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.26 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.18 TOTAL: $222.94 Issued Date: 11/5/2019 1 of 2 41-m-\* aS �'� ;, ROOF NON SHINGLE PERMIT PERMIT NUMBER 4 CITY OF ATLANTIC BEACH ROOF19-0078 ,vi 800 SEMINOLE ROAD ISSUED: 11/5/2019 `'';nr ATLANTIC BEACH. FL 32233 EXPIRES: 5/3/2020 { Issued Date: 11/5/2019 2 of 2 C ,:Lyr.„ City of Atlantic Beach APPLICATION NUMBER t . Building Department (To be assigned by the Building Department.) 800 Seminole Road Roc:,P ( c) _OO7-N Atlantic Beach, Florida 32233-5445ll lJ 4/0v Phone(904)247-5826 • Fax(904)247-5845 Date routed: d I~] ( � �.wi 9'' E-mail: building-dept@coab.us City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Co ' Dreview required Yes No Property Address: � J� � ���iC1 Tt-Yv��(2.ciepartment uildin Applicant: LAC tAG 0 _C.) tanning &Zoning Tree Administrator Project: ` �`tA(- eoc c- Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Other Agency Review or Permit Required of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: t Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: UILDIN PLANNING &ZONING Reviewed by: Date:/U''2--/, TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 . OFFICE COPY , `•'`''r: ' Building Permit Application Updated l0/9/18 �.�)1,. City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY .._3._i,r; Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED. Phone: Job Address: 1 5(I1 Q mac a�l'Q.bAN---,\)-0...) Permit Number: r� \ CO1:1 9 --v v 7 Legal Description i 01- -1 t LX) "�j,C 3�1— G1L, lccdl C.-,l tal,1.0 1 rf Iu1tl 1(>795 t 5 — 19 7S Valuatiotn of work Repla(Replacement Cost)$ r uIU L) Heated/Cooled SF Non-Heated/Cooled • Class of Work: 'sew ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s); ❑Commercial sidential • If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No • Will tree(s)be removed in association with proposed Project?[Res(must submit separate Tree Removal Permit) ❑No Describe in detail the type of work to be performed: 1)3 t� (•\'Ct\ Go -- Florida Product Approval# for multiple products use product approval form Property Owner Information ` `u Name ChCL %`15.--)tC- 7 A\V. \ Address c: i1;� 1 L• is+.3 1,11).11- 1 U City __:Sa,e_t_5s,)•. State H. Zip ..x15C) Phone E-Mail Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Contractor Information Name of CompanyC. 6 Qualifying Agent b I Ct. P�1.9'�,f.�� ,J Address 2,41.\\I (c 1T •+>t_ e city 1 State c\ Zip s` Office Phone (cjb 2' RJob Site Contact Number State Certification/Registration# e, _ 4 iy- E-Mail (%nay\( EU.' QC ntji. ti _c,j1[IN\ Q Architect Name&Phone# Engineer's Name&Phone# W r Workers Compensation Insurer 11\c- OR Exempt o Expiration Date a C Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or Installation has< = J 2 I commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating J Q O construction In this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, d. < O h WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this,— W — 0 permit,there may be additional restrictions applicable to this property that may be found In the public records of this county,and C) 0 O there may be additional permits required from other governmental entities such as water management districts,state agencies,orU V 0 V federal agencies, O r.: CC 2 OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all aL .4 applicable laws regulating construction and zoning. n. U) N WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY 0 LL. g 41 RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND G Z0 z 12 i TO OBTAIN FINANCI . INSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE F- w 5 L RECORDING Yji� ICE ► ' O% MENCEMEN w V 1� w a� u d•..L.. • /2.-... ( f••••- . 'gent) — (Signature of Cony: or) (_ II a Si ned and sworn to(or affirmed)before me this 1> day ofigne�d and sworn to or affirmedh before 'ne'this , day of 1'I ,by irflE c��� —, 1 ,b` L nt! _...� -vcd- i It c At_-u `" f ` 0 ature of otary) (Signature of Notary) tirnvp�,� ^ V'..P.1":"'„,'-41-u` SHANNON EAGLE•WYMAN I o ,... r VIRGINIA K GRIMES lf}-Personal Known OR ( Notary Public-State of Florida [Personally Known OR r 4 CCC [ ]Produced Identificati Commission#GG 105200 [ ]Produced Identification ,-A1C^i'' Commission a GG 332415 Type of Identification: '':•:. � P Expires May 1fi�2071 Type of Identification: ( �'T'oi,if• My Comm.Expires May 8.2023 ` O wailve ti.,uvsl.NativNt Notary AIM-4 or r•LC' Bonded TAru eudpml Notary S.rvlw Recorded 02/07/2019 09:39 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10 .00 OFFICE COPY 9`NO,z E OF COMMENCEMENT e�f / 7 (PREPARE IW QUPUCATE) Permit N. --_ ==• Tax Folio No. Stale of to♦t County of,.orJ & To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following Information is stated in this NOTICE OF COMMENCEMENT. Legal description of gopeny being improved: (,o7-___�, , 'f A\-\(\i\kr g, r ich Cnm.,1\--`cr eA v-,\11 t V,.k op t„p-ir 13 L" Address of properly eing improved: 16 4 t, }-tf"Af x me t 10.k l.Js e-- A.\,pn\-,eer�c L a 33 l General description of improvements: 1me,....,-) S\�C1e $.cam:,l`tj l i44 Owner G.-NetiAl C1 ONG' i.eQ+ 2atMil,;51N 1 i Address —8 164- Skr �' 3 t�trltf-� �Dt j , D(10 i I�tw ?, Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address ��iri.M c Contractor, foi t•e"( ,7j 'Mf101.10L • r Address If-S71)I -4ry; l 5 \yflty ey� , e a.c. ,a^7(o�iVVI. i L Phone No.ei D-i- Log -+ J-7 Fax No. Surely(if any) Address Amount of bond S Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No, ' Name of person within the State of Florida,other than himself.designated by owner upon whom notices or other documents may be served: Name Address - Phone No, Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienors Notice as provided in Section 713.06(2)(b).Florida Statutes.(Fill in at Owner's option), Name Address Phone No. Fax No: Expiration date of Notice of Commencement(the expiration date is one(11 year from the date of recording unless a different date is specified): •THIS SPACE FOR RECORDER'S USE ONLY //% OWNER —•, t 21:5M/ Beeeate metres day orCl 2Al'I rn lhfi %ay c apva`f aawsnoty area �eiiioy Mts,lc ia!sar. ea'c dsd.+aii.r 5 tlerei.r are;rue and accurate tipr',o CYNTHIA HCOLLINS t �if //�� I ,.. . . Notary Public-State of Florida k t aLsl _: d � .., Commission#GG 275622 2 ner. f Fdkno of ceJJs464e141;31.. t�q(c ar �ouL•> d s�.•:• My Comm.Expires Nov 14,2022 , Mc o,,r;s c expect-T�fOYCrrior * j 0 MnAed through National Notary Assn. I t' P2rMnary KnbMf Produced IdetU'Tcco!roaXX — 01.11111M OFFICE COPY J,.,,:5L•'J(f s .; .\‘ - PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) -.._„,„,,__?..,-,- *Project J il» *Project Address: 1596 Maritime Oak Drive Atlantic Beach, Fl. 32233 Permit#: Rea p/9-6p7s---- *Owner/Project Name: Christopher Zalupski /ABCC Lot 136 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s)for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1.Swinging 2.Sliding 3. Sectional 4. Garage Roll-Up 5.Automatic 6. Other B.WINDOWS - 1.Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6.Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 1 of 4 Updated 10/17/18 OFFICE COPY Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1. Siding 2.Soffits 3. EIFS 4.Storefronts 5. Curtain walls 6.Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10.Synthetic stucco 11. Other D. ROOFING PRODUCTS 1.Asphalt shingles 2. Underlayments C.\\-\ C:k_ ►WA'1c..2C Et 5554 -ZA 3. Roofing fasteners 4. Nonstructural metal millennium metals "m seam"steel 26 gaugel6" Fl 5211 .3 R7 roof 5. Built-up roofing 6. Modified bitumen 7.Single ply roofing 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16.Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 10/17/18 OFFICE COPY In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. 4.) *Contractor Name (Print Name):Cynthia Pa *Contractor Signature: fit, ; *Company Name: Cache CO. LLC *Mailing Address: 3616 Warrington Street *City: Jacksonville *State: Fl *Zip Code: 32254 *Telephone Number: (904) 887-7663 *E-mail Address: Cindy@cachero0fing.com Cell Phone Number: Fax Number: Page 4 of 4 Updated 10/17/18 CBUCK Engineering OFFICE COPY s:,3PC:;Ir1l1"t4 Sia it Jt—t{-1r irw.4 CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "M-Seam" Metal Roof Assembly Manufacturer: Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 (877) 358-7663 for Florida Product Approval # FL 5211.3 R7 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: "M-Seam" Material: Steel Panel Thickness: 26 gauge, (Minimum) Panel Width: 16" Facsimile of digital copy signed by James L.Buckner,P.E. Support: Wood Deck Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-23. \\\\\I11I111/i/,,, F' Prepared by: �P.•'•\,\CENS •.•F,p James L. Buckner, P.E., SECB _ * No 31242 Florida Professional Engineer # 31242 :3 * w. Florida Evaluation ANE ID: 1916 STATE OF .• Report No. 17-196-M-S6W-ER ��///7/ONA1.- \\\\\ (Revises 15-104-M-S6W-ER) I1I111\\ Date: 10/ 16/ 17 Contents: Evaluation Report Pages 1 —7 2017.10.1920:13:36-04'00' CBUCK,Inc.—Palm Beach County, Florida Phone:(561)491-9927• Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net Main Office: 1374 Community Drive,Jupiter, Florida 33458 FL#: FL 5211.3-R7 Date: 10/ 16/ 17 CBUCK Engineering Report No.: 27of M-S6W-ER Specialty St ruck wal Entaineeving CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Millennium Metals, Inc. Product Name: "M-Seam" Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System "M-Seam" Description: 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials&standards: Evaluated: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.)or 19/32"or greater plywood, • or Wood plank(min. specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: Refer to Table"A" (Refer to"Table A" attachment details herein) FL#: FL 5211.3-R7 Date: 10/16/ 17 CBUCKEngineering Report No.: 17-196-M-S6W-ER Page 3 of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06—Test for Uplift Resistance of Roof Assemblies • UL 1897-12—Uplift test for roof covering systems Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 6th Edition (2017). • The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-12 standard version adopted by the Florida Building Code 6th Edition (2017). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 6th Edition (2017),Section 1504.3.2. Evaluation Report Scope: This product evaluation is limited to compliance with the structural requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and •Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20- 3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval". •Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for"project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. •This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61620-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure,site specific or permit design. •All metal components and fasteners shall be corrosion resistant in accordance with applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. •This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade&Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization#:QUA 1824). \ CBUCK Engineerings FL#: Date: FL 5211.3-R 7 10/ 16/ 17 No.:P :rt 4of 7 Speciathy Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Components/Materials Roof Panel: (by Manufacturer): Product Identification: M-Seam Material: Steel Thickness: 26 gauge Minimum Panel Width: 16" (max.)Coverage Rib Height: 1" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Fastener: Type: Pancake-Head Wood Screw Size: #10(x length to meet min. penetration through deck) Penetration Through: 3/16" min.through wood deck Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME 818.6.4 Components/Materials Underlayment: (by Others): Material and application shall be in compliance with FBC Section 1507.1.1 and in accordance with applicable code sections and manufacturer's recommendations. Insulation(Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(lbs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: FL 5211.3-R7 Date: 10/16/ 17 CBUCK Engineering Page rt No.: 57-1 6 M-S6W-ER CBUCK,Inc.Certificate of Authorization t#8064 Specialty Structural Engineering Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.) • Fastener spacing: Refer to Table"A"Below (along the length of the panel) • Rib Interlock: Snap Lock (Panel ribs shall be fully engaged to form an integral interlock.) • Minimum fastener penetration thru bottom of support,3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE"A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32"or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASD)with a margin of safety of 2 to 1. Install the "M-Seam" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94& UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC(FBC Organization#TST ID: 1527) Report#: 0232-0508-05, Report Date: 6/29/05,Specimens#1-3 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Millennium Metals Licensee#423 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL#: FL 5211.3-R7 Date: 10/ 16/ 17 CBUCK Engineering Page rt No.: 3.6o7 -M-S6W-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Profile Drawings 1" j____ L.....0 - 16'Cover 0I I 1 1 _ 1I- co Striatials 3/4 Type:Ancil Rib a Striated Typical Panel Profile View (Not To Scale) 16"o.c. <---- ' ___ -1-_-_—_-_---- ---------------- —--- ----- _____ , 411 i _. Integral Snap Lock #10 Pancake-Head Screw _ 3/16'min. penetration thru deck i MA Typical Assembly Profile View (Not To Scale) FL#: FL 5211.3-R7 Date: 10/ 16/ 17 CHUCK Engineering Page::rt No.: ;7-1 M-196 -ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Fastener: #10 Pancake-Head Screw—- M,Sear�i'RnOf Pard r------- — / •' ; 8"o.c Typical / Support: �--------Insulation: -15/32"or 19/32"CDX Plywood Deck,or (Optional)3"max or 25 psi min. -Mod plank Typical Assembly Profile View (Not To Scale) TABLE "A" ALLOWABLE LOADS - METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32" or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASD)with a margin of safety of 2 to 1. MILLENNIUM Arth METALS, INC. OFFICE COPY 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 Net Coverage 1 6" Nominal „__„PANEL PROFILE DIMPLE APROX. EVERY 4' 0.C. STARTER/END / SLOT APROX. 2” FROM PANEL ENDS /� 4 � 2.t Sidelap Detail Nailstrip Detail NOTES: 1 . M-Seam Panels are only available with minor ribs to reduce oil canning. 2.Oil canning is inherent to all metal panels and therefore is not considered a manufacturers defect nor a warranty condition. 3.Consult your contractor immediately if you need information concering this condition. Gauge Finishes Nominal Thickness ASTM & Grade Specifications 26 Acrylic Galvalume .0179 ASTM A-792 AZ55 26 PTD Galvalume * .0179 ASTM A-792 AZ55 24 Acrylic Galvalume .0240 ASTM A-792 AZ55 PTD Galvalume is 70%Kynar 500 or Hylar 5000 PVDF Resin unless otherwise indicated. Millennium Metals Offers a Limited 25 year warranty on Painted Panels,20 year limited warranty on Mill Finished Acrylume Panels. Please request warranty information from your distributor. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 M-Seam Installation Instructions: Panel Attachment: M-Seam recommended attachment is 8" on center along the edge of the nailer strip. This attachment may not be suitable for all applications. Projects may require an engineer to evaluate conditions such as mean height, exposure type, and roof configuration as indicated in ASCE 7-98 and ASCE 7-02. Additional fasteners may be required along the end zones on the panel (eave, ridge, and perimeter). Pitch Alert: This product should not be used on applications less than a 2/12 pitch. Roof Application: Step 1: Make sure deck is even and square. Step 2: Panel should begin on the gable end opposite of the prevailing wind. Begin with the receiving edge of panel (female side) along the Gable (see Gable Rake Detail). The edge away from the Gable should be the nailstrip. After checking that the panel is square to the eave, make sure the panel is attached as indicated in panel attachment(see above) and also 2" from the leading and trailing end of the panel on the nailstrip. The screw should be placed in the center of the nailstrip slot provided. Sealant is recommended on applications less than a 3/12 pitch. Step 3: After attaching the first panel completely, panel 2 should be snapped in place using a rubber mallet. A minimum of 1" overhang is recommended at the eave. Typical eave detail requires the use of a hemming tool to hem the panel over the ED2 (detail has 1-1/2" overhang). Install the remaining accessories. Millennium Metals offers a variety of products such as pipe boots, butyl tape, and ventilation materials. Do not use copper or lead products in conjunction with M-Seam as it will void the warranty. ATTENTION INSTALLER: PLEASE REFER TO THE IMPORTANT NOTE SECTION OF THIS MANUAL FOR SAFETY, STORAGE, OIL CANNING DISCLAIMER, AND SHAVING DISCLAIMER PRIOR TO BEGINNING PROJECT. Code requirements vary from area to area and job type as well as roof configuration. Job specific engineering is not a service provided by Millennium Metals. Estimates/Takeoffs are provided at a nominal fee for materials only. It is the sole responsibility of the customer to review the takeoff and make any changes to the quantity, length or accessories he/she feels necessary. Millennium Metals takes no responsibility as to the accuracy of the information provided. M-Seam is a special order product and therefore is not returnable. Please verify all items prior to ordering. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 2 MILLENNIUM METALS , INC . 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 Important Notes: Millennium Metals recommends licensed roofing professionals to install our materials. Please use gloves, glasses, and other protection when handling material to prevent injury. It is necessary to inspect deck integrity to insure it is safe to walk on before beginning any work. Millennium Metals recommends all installers follow the OSHA requirement for fall protection. Never walk on materials when wet or when unsuitable weather conditions are present. Storage: Materials should be installed immediately. Any unused materials should be stored in a dry place where moisture will not reach and penetrate bundles. Material should always be placed on wood block to separate from the ground or concrete. Do not cover with plastic!!! Instead, use loose canvas tarps so that air can circulate. Cut the bands so that the material can expand. Millennium Metals warrants the material only. We do not offer weather tightness warranties. Any such warranty is up to the contractor to include in their contract. Decking: Millennium Metals recommends the use of minimum 1/2" plywood or OSB Board attached in accordance with code. The deck must be supported by an engineered truss system not to exceed 24" on center. A moisture barrier such as 30# felt or other ASTM approved underlayment should be used over decking to control moisture. Metal should never come in direct contact with green or pressure treated lumber as it will cause corrosion. If tin tabs are required to attach felt it will be necessary to apply a 15# felt in the direction of the panel as an additional separation barrier. M-seam is recommended on application with 2-1/2/ 12 or greater. Oil Canning Disclaimer: Oil canning is industry wide and inherit to all metal panels. It is more visible in designs with flat spans as with this panel. Oil canning is a wavy appearance in the surface of the metal panel. This slight distortion in no way effects the warranty nor is a reason for rejection or refusal. Shavings Disclaimer: When using fasteners to penetrate steel sheets the iron particles tend to go airborne and settle on the sheet. It is necessary to remove these particles to prevent embedment and rust marks. MILLENNIUM METALS INC. TOLL FREE: 1 -877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 3 MILLENNIUM AINMETALS, INC. M-SEAM DETAIL LOCATIONS 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 SR-1 RC-10 GR-9 RC 15 RAKE EDGE SW-3 RIDGE �,,.. PAGE 8 PAGE 6 -- SW-4 , Do SIDEWALL = 0 PAGE 10 F TF-2 o j — TRANSITION EW-3 _ _ PAGE 9 Z ENDWALL m PAGE 11 _-- ____ ________-> 4 110.‘14: 0 ��- HS-1 ` � `� HIGH SIDE EAVE IV‘1 �/ PAGE 7 _ • ice" \ %,,01,44,,, ill ,� . A ,., - r / 4 . �--.4 ;,IIEl ,,, ED-2 PANEL PROFILE PAGE1 „ ,.. - 1 4 EAVE DRIP PAGE 7 SW-4 or SW-3 PV-3 RC-10 g SIDEWALL VALLEY HIP m PAGE 10 PAGE 9 PAGE 6 4, MILLENNIUM Artta METALS , INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 1. SAVE DRIP (EF-5) 2. ENDWALL FLASHING (FW-3) 3. EXTENDED EAVE (ED-2) 3. EXTENDED EAVE (ED-2R) J 3 3/D PAINT S 3/8, PAINT 4 3/4" PAINT `� _ PAINT ,/N N x 5/8' '' 4 1/2 2 1/2" 1 1/2" "----.7:V1 1/2" 1/2J� — �C�S/8" x 5/8" 1/ OVERHANG: 1-3" OVERHANG: 1-3" 4. GABLE RAKE (GR-9) 4. GABLE_RAKE (GR-9R) 5. GAMBREL FLASHING (GF-2) 6. HIGHSIDE EAVE (HS-1) 3-1/8" 3-1/4" y 7-1/4" � 1� " -cl +F 1:., 5/8 7 GGG \ M 5/8")5p2• )5CX1/2" J 5/8" a _ "JC 5/8"�( /� 1/2" 1/ 'X 2" 5/8 ( 7. HIP CAP (RC-10) 8. J–CHANNEL (JC-7) 9. PREFORMED VALLEY (PV-3) 10. STEP SIDEWALL (SW-4) 5,55 4-1/2" 9-'1/ •. M –3/8" \\ 1" 1-3/8" 2-7/8" II 5/8" 1" 11. TRANSITION FLASHING (TF-2) 12. SIDEWALL FLASHING (SW-3) 13. STEP RAKE (SR-1) 14. COUNTER FLASHING (CF-1) 1/2">( 3" 1' co g, 6" M 3-3/8" N 1-1/16" M I II \ x 3/4. '1 - 41/2" 1/2"1 M 25( 5/8" U1/2" �c 3/4" 15. RIDGE CAP (RC-20) CLEAT OFFSET CLEAT (CL-2) Z–CLOSURE (ZC-1) REGLET FLASHING CRF-1) 1" 1/2„ 6,117:. 1-1/2" 1" 1--IL LO N �( I' I TTTT \ - 1* M I L N 1 3/8" 1 I L FLASHING PROFILES MILLENNIUM METALS INC. TOLL FREE: 1 -877-358-7663 FAX.904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 5 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 STITCH SCREWS 0 12" O.C., DO NOT OVERDRIVE RIDGE CAP _= M-SEAM PANEL VENTING MATERIAL 30# FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE VENTED RIDGE DETAIL RC- 15 • 4410V:441 M-SEAM PANEL S.S. POP RIVETS "Z" CLOSURE CUT TO FIT BETWEEN PANEL, (3) #10-12 X 1" PANCAKE HEAD SCREWS PER PANEL CONT. BUTYL TAPE SEALANT APPROVED SOLID SUBSTRATE #30 FELT ATTACHED PER CODE HIP/RIDGE FLASHING RIDGE CAP RC- 10/RC-20 MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 6 MILLENNIUM 411t4 METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 0 M-SEAM HEMMED ® SEE DETAIL FOR HEMMING #10-12 X 1" PANCAKE PANEL PAGE 3 .•01 HEAD SCREWS ® 12" O.C. M-SEAM PANEL #30 FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE CLEAT IN/ #10-12 X 1" PANCAKE HEAD SCREW 0 12" O.C. FASCIA BOARD EAVE DRIP DETAIL ED-2 EAVE FLASHING PANEL DETAIL MAKE IT FLUSH AND SHORT TO DEPICT HOLE. S.S. POP RIVETS M-SEAM PANEL 0 12" 0.C. HIGH-SIDE EAVE FLASHING "Z" CLOSURE CUT TO FIT BETWEEN PANEL, (3) #10-12 X 1" PANCAKE HEAD SCREW PER PANEL irriAlr A APPROVED SOLID SUBSTRATE #30 FELT ATTACHED PER CODE CLEAT W/ #10-12 X 1" PANCAKE HEAD SCREWS ® 12" O.C. CONT. BUTYL TAPE SEALANT HIGHSIDE EAVE DETAIL HS- 1 MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX.904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 7 MILLENNIUM oilltia METALS , INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 /,*/rrr// �, S EN D -714. , wi,n/i/*iir�rrr _ %, v ,-- lIb fir 14141,. FIELD BEND PANEL 1" MIN. 1. ////// CONT. BATYL LAN TAPE SEALANT STITCH SCREWS . "'/ 0 12' O.C. ' 11�ii� 301 FELT ATTACHED PER CODE 1 STITCH SCREWS 0 12" O.C. M-SEAM PANEL ,''1,44i CONT. BUTYLTAPE SEALANT ,,+r//'/r/ STEP GABLE FLASHING STAT /%5 APPROVED SOLID SUBSTRATE FASCIA CLEAT W/#10-12 X 1" STEP GABLE RAKE DETAIL SR- 1 PANCAKE HEAD SCREWS /.//,�//,�//'. 4 E N D /./i/�r//.r //wi It/,.,, i//, FIELD BEND /l// PANEL 1" MIN. CONT. BUM TAPE SEALANT it 'Z" CLOSURE �/ GABLE FLASHING STITCH SCREWS o4.P* 130 FELT O 12" O.C. `-. ATTACHED PER CODE I11r Il APPROVED SOLID SUBSTRATE `�� /� M-SEAM PANEL i ® it_/i "Z" CLOSURE CUT TO FiT BETWEEN PANEL, (3) #12 X 1 WHS PER PANEL STA T i` CONT. BUM TAPE SEALANT FASCIA CLEAT W/ #10-12 X 1" PANCAKE HEAD SCREWS GABLE RAKE DETAIL GR-9 MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 8 MILLENNIUM isillt4 METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 ik /; H.. sr . N-SEAM PANEL #30 FELT ATTACHED PER CODE -VALLEY FLASHING APPROVED SOLID SUBSTRATE CLEAT SET IN BUTYL TAPE CONT. BUTYL SEALANT W/ #10-12 X 1" TAPE SEALANT PANCAKE HEAD SCREWS 6" O.C. PREFORMED VALLEY DETAIL PV-3 OFFSET CLEAT SET IN BUTYL TAPE SEALANT W/ #10-12 X 1" PANCAKE O HEAD SCREWS 0 12" O.C. ��- • TRANSITION FLASHING S.S. POP RIVETS 0 12" O.C. .`►I fr♦•✓P 10 CONT. BUM TAPE SEALANT 7" CLOSURE CUT TO FIT BETWEEN PANEL, (3) #10-12 X 1" PANCAKE SCREWS PER PANEL M-SEAM PANEL 30# FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE TRANSITION DETAIL MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 9 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 SEALANT CONT. BUTYL SEALANT TAPE SEALANT SURFACE-MOUNT CONT. BUTYL TAPE COUNTER FLASHING � � _ (. SEALANT 1:. SIDEWALL FLASHING ® S.S. POP RIVET ,�, 1 COUNTER FLASHING I ® 12" O.C. �' "Z" CLOSURE CUT TO FIT . STEP SIDEWALL BETWEEN PANEL, (3) #12 X 1 FLASHING PANCAKE SCREWS PER PANEL #30 FELT ATTACHED PER CODE CONT. BUTYL TAPE APPROVED SOLID-- � SEALANT SUBSTRATE 41111114b..4\. #30 FELT /Iq#A. '1111iSTITCH SCREWSATTACHED PER CODE 4#464. 441 • 12" O.C. APPROVED SOLID CONT. BUTYL TAPE SUBSTRATE SEALANT M-SEAM PANEL M-SEAM PANEL SIDEWALL FLASHING DETAIL SW-3 & SW-4 SIDING/STUCCO ...11111111 SEALANT ��' SEALANT Apt- z.hr H� CONT. BUTYL �;i Pe REGLET ` �� TAPE SEALANT FLASHING �. i FLASHING SAW CUT CONT. BUTYL / llriP14 I TAPE SEALANT SIDEWALL FLASHING ir% i CONT. BUTYL TAPE SEALANT MASONARY WALL STEP SIDEWALL FLASHING SIDEWALL COUNTER FLASHING OPTIONS MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 10 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 .E; Co I!. IDSEALANT jib ; CONT. BUTYL TAPE SEALANT SURFACE MOUNT COUNTER FLASHING HEADWALL FLASHING tAL\* '76 CAULK 0 ALL SEAMS N ...........#PP CONT. BUTYL TAPE SEALANT •* "Z" CLOSURE CUT TO FIT BETWEEN PANEL, (3) #10-12 X 1" PANCAKE HEAD SCREWS PER PANEL Ni S.S. POP RIVETS 'Q M-SEAM PANEL APPROVED SOLID SUBSTRATE //���/" #30 FELT ATTACHED PER CODE -i //" ENDWALL DETAIL EW-3 SIDING/STUCCO _, SEALANT ��� SEALANTArp41 1���,�''�♦��� CONT. BUTYL �• REGLET 41111W9,1- �� TAPE SEALANT 1i.P - FLASHING �. iv FLASHING SAW CUT Oil CONT. BUTYL iPPPP i.dSIDEWALL TAPE SEALANT CONT. BUTYLTAPE SEALANT FLASHING MASONARY WALL STEP SIDEWALL FLASHING ENDWALL COUNTER FLASHING OPTIONS MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 11 MILLENNIUM oilltta METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 PANEL HEMMING L� _ , A 7 - , , ::-.......cD'' !, S !!! • ;c, J���� % S ...,_.. II ,b ..4,.. ....... ,,,,„ ... .... CAULK CUT PANEL BACK 1 i" TO CREATE HEM. USE HEMMING TOOL. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 12 CITY OF ATLANTIC BEACH BUILDING DEPARTMENT (' ' - ) 800 SEMINOLE ROAD (---- ' Y _' ATLANTIC BEACH, FL 32233 �Jiil9% CERTIFICATE OF COMPLETION ROOF19-0078 ROOF NON SHINGLE ISSUED: JOB ADDRESS: REAL ESTATE NUMBER: ZONING: 2/14/2020 1596 MARITIME OAK DR 169505 1975 DESCRIPTION OF WORK: METAL ROOF OWNER: CONTRACTOR: ZALUPSKI CHRISTOPHER E CACHE CO LLC 633 W 46TH ST JACKSONVILLE, FL 32208 APPROVED: DI k-----4. glir°A CHIEF BUILDING OFFICIAL VOID UNLESS SIGNED BY BUILDING OFFICIAL