1596 Maritime Oak Dr ROOF19-0078 Metal r,�„:-1,....,,,-,),,„, ROOF NON SHINGLE PERMIT PERMIT NUMBER
(4'C*:: ',� ROOF19-0078
�, ,
jCITY OF ATLANTIC BEACHISSUED: 11/5/2019
- 800 SEMINOLE ROAD
ATLANTIC BEACH. FL 32233 EXPIRES: 5/3/2020
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
1596 MARITIME OAK DR ROOF NON SHINGLE METAL ROOF $18877.00
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
169505 1975 ATLANTIC BEACH
COUNTRY CLUB UNIT 02
COMPANY: ADDRESS: CITY: STATE: ZIP:
CACHE CO LLC 633 W 46TH ST JACKSONVILLE FL 32208
OWNER: ADDRESS: CITY: ' STATE: ZIP:
ZALUPSKI CHRISTOPHER E
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
(Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $145.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $72.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.26
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.18
TOTAL: $222.94
Issued Date: 11/5/2019 1 of 2
41-m-\*
aS �'� ;, ROOF NON SHINGLE PERMIT PERMIT NUMBER 4
CITY OF ATLANTIC BEACH ROOF19-0078
,vi 800 SEMINOLE ROAD ISSUED: 11/5/2019
`'';nr ATLANTIC BEACH. FL 32233 EXPIRES: 5/3/2020 {
Issued Date: 11/5/2019 2 of 2
C
,:Lyr.„ City of Atlantic Beach APPLICATION NUMBER
t . Building Department (To be assigned by the Building Department.)
800 Seminole Road
Roc:,P ( c) _OO7-N Atlantic Beach, Florida 32233-5445ll lJ
4/0v Phone(904)247-5826 • Fax(904)247-5845 Date routed: d I~] ( �
�.wi 9'' E-mail: building-dept@coab.us
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Co ' Dreview required Yes No
Property Address: � J� � ���iC1 Tt-Yv��(2.ciepartment
uildin
Applicant: LAC tAG 0 _C.) tanning &Zoning
Tree Administrator
Project: ` �`tA(- eoc c- Public Works
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Review or Receipt
Other Agency Review or Permit Required of Permit Verified By Date
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: t Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
UILDIN
PLANNING &ZONING
Reviewed by: Date:/U''2--/,
TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
. OFFICE COPY
, `•'`''r: ' Building Permit Application Updated l0/9/18
�.�)1,.
City of Atlantic Beach Building Department **ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
.._3._i,r;
Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED.
Phone:
Job Address: 1 5(I1 Q mac a�l'Q.bAN---,\)-0...) Permit Number: r� \ CO1:1 9 --v v 7
Legal Description i 01- -1 t LX) "�j,C 3�1— G1L, lccdl C.-,l tal,1.0 1 rf Iu1tl 1(>795 t 5 — 19 7S
Valuatiotn of work Repla(Replacement Cost)$ r uIU L) Heated/Cooled SF Non-Heated/Cooled
• Class of Work: 'sew ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door
• Use of existing/proposed structure(s); ❑Commercial sidential
• If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No
• Will tree(s)be removed in association with proposed Project?[Res(must submit separate Tree Removal Permit) ❑No
Describe in detail the type of work to be performed: 1)3 t� (•\'Ct\ Go --
Florida Product Approval# for multiple products use product approval form
Property Owner Information ` `u
Name ChCL %`15.--)tC- 7 A\V. \ Address c: i1;� 1 L• is+.3 1,11).11- 1 U
City __:Sa,e_t_5s,)•. State H. Zip ..x15C) Phone
E-Mail
Owner or Agent(If Agent,Power of Attorney or Agency Letter Required)
Contractor Information
Name of CompanyC. 6 Qualifying Agent b I Ct. P�1.9'�,f.�� ,J
Address 2,41.\\I (c 1T •+>t_ e city 1 State c\ Zip s`
Office Phone (cjb 2' RJob Site Contact Number
State Certification/Registration# e, _ 4 iy- E-Mail (%nay\( EU.' QC ntji. ti _c,j1[IN\ Q
Architect Name&Phone#
Engineer's Name&Phone# W r
Workers Compensation Insurer 11\c- OR Exempt o Expiration Date a C
Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or Installation has< = J 2 I
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating J Q O
construction In this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, d. < O h
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this,— W — 0
permit,there may be additional restrictions applicable to this property that may be found In the public records of this county,and C) 0 O
there may be additional permits required from other governmental entities such as water management districts,state agencies,orU V 0 V
federal agencies, O r.: CC 2
OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all aL .4
applicable laws regulating construction and zoning. n. U) N
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY 0 LL. g 41
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND G Z0 z 12 i
TO OBTAIN FINANCI . INSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE F- w 5 L
RECORDING Yji� ICE ► ' O% MENCEMEN w V 1� w
a� u
d•..L.. • /2.-...
( f••••- . 'gent) — (Signature of Cony: or) (_ II
a
Si ned and sworn to(or affirmed)before me this 1> day ofigne�d and sworn to or affirmedh before 'ne'this , day of
1'I ,by irflE c��� —, 1 ,b` L nt!
_...� -vcd- i It c At_-u `" f `
0 ature of otary) (Signature of Notary)
tirnvp�,� ^ V'..P.1":"'„,'-41-u` SHANNON EAGLE•WYMAN I
o ,... r VIRGINIA K GRIMES lf}-Personal Known OR ( Notary Public-State of Florida
[Personally Known OR r 4 CCC
[ ]Produced Identificati Commission#GG 105200 [ ]Produced Identification ,-A1C^i'' Commission a GG 332415
Type of Identification: '':•:. � P Expires May 1fi�2071 Type of Identification:
( �'T'oi,if• My Comm.Expires May 8.2023 `
O wailve ti.,uvsl.NativNt Notary AIM-4
or r•LC' Bonded TAru eudpml Notary S.rvlw
Recorded 02/07/2019 09:39 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY
RECORDING $10 .00
OFFICE COPY
9`NO,z E OF COMMENCEMENT
e�f /
7 (PREPARE IW QUPUCATE)
Permit N. --_ ==• Tax Folio No.
Stale of to♦t County of,.orJ &
To whom it may concern:
The undersigned hereby informs you that improvements will be made to certain real property,and in
accordance with Section 713 of the Florida Statutes,the following Information is stated in this NOTICE OF
COMMENCEMENT.
Legal description of gopeny being improved: (,o7-___�, , 'f
A\-\(\i\kr g, r ich Cnm.,1\--`cr eA v-,\11 t V,.k op t„p-ir 13 L"
Address of properly eing improved: 16 4 t, }-tf"Af x me t 10.k l.Js e--
A.\,pn\-,eer�c L a 33 l
General description of improvements: 1me,....,-) S\�C1e $.cam:,l`tj l i44
Owner G.-NetiAl C1 ONG' i.eQ+ 2atMil,;51N 1 i
Address —8 164- Skr �' 3 t�trltf-� �Dt j , D(10 i I�tw ?,
Owner's interest in site of the improvement
Fee Simple Titleholder(if other than owner)
Name
Address
��iri.M c
Contractor, foi t•e"( ,7j 'Mf101.10L •
r
Address If-S71)I -4ry; l 5 \yflty
ey� , e a.c. ,a^7(o�iVVI. i L
Phone No.ei D-i- Log -+ J-7 Fax No.
Surely(if any)
Address Amount of bond S
Phone No. Fax No.
Name and address of any person making a loan for the construction of the improvements.
Name
Address
Phone No. Fax No,
' Name of person within the State of Florida,other than himself.designated by owner upon whom notices or other
documents may be served:
Name
Address -
Phone No, Fax No.
In addition to himself,owner designates the following person to receive a copy of the Lienors Notice as provided in
Section 713.06(2)(b).Florida Statutes.(Fill in at Owner's option),
Name
Address
Phone No. Fax No:
Expiration date of Notice of Commencement(the expiration date is one(11 year from the date of recording unless a
different date is specified):
•THIS SPACE FOR RECORDER'S USE ONLY //%
OWNER
—•, t
21:5M/
Beeeate metres day orCl 2Al'I rn lhfi
%ay c apva`f aawsnoty area �eiiioy
Mts,lc ia!sar. ea'c
dsd.+aii.r 5 tlerei.r
are;rue and accurate
tipr',o
CYNTHIA HCOLLINS t
�if //�� I ,.. . . Notary Public-State of Florida k t
aLsl _: d � .., Commission#GG 275622 2
ner. f Fdkno of ceJJs464e141;31..
t�q(c ar �ouL•> d s�.•:• My Comm.Expires Nov 14,2022 ,
Mc o,,r;s c expect-T�fOYCrrior * j 0 MnAed through National Notary Assn. I t'
P2rMnary KnbMf
Produced IdetU'Tcco!roaXX
— 01.11111M
OFFICE COPY
J,.,,:5L•'J(f s .;
.\‘ - PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED)
-.._„,„,,__?..,-,-
*Project
J il»
*Project Address: 1596 Maritime Oak Drive Atlantic Beach, Fl. 32233 Permit#: Rea p/9-6p7s----
*Owner/Project Name: Christopher Zalupski /ABCC Lot 136
As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s)for
the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your
product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product
approval may be obtained at:www.floridabuilding.org.
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
A. EXTERIOR DOORS
1.Swinging
2.Sliding
3. Sectional
4. Garage Roll-Up
5.Automatic
6. Other
B.WINDOWS -
1.Single hung
2. Horizontal slider
3. Casement
4. Double hung
5. Fixed
6.Awning
7. Pass-through
8. Projected
9. Mullion
10. Wind breaker
11. Dual action
12. Other
Page 1 of 4 Updated 10/17/18
OFFICE COPY
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
C. PANEL WALL
1. Siding
2.Soffits
3. EIFS
4.Storefronts
5. Curtain walls
6.Wall louvers
7. Glass block
8. Membrane
9. Greenhouse
10.Synthetic stucco
11. Other
D. ROOFING PRODUCTS
1.Asphalt shingles
2. Underlayments C.\\-\ C:k_ ►WA'1c..2C Et 5554 -ZA
3. Roofing fasteners
4. Nonstructural metal millennium metals "m seam"steel 26 gaugel6" Fl 5211 .3 R7
roof
5. Built-up roofing
6. Modified bitumen
7.Single ply roofing
8. Roofing tiles
9. Roofing insulation
10.Waterproofing
11.Wood shingles/shakes
12. Roofing slate
13. Liquid applied roofing
14. Cement-adhesive
coats
15. Roof tile adhesive
16.Spray applied
polyurethane roof
17. Other
Page 2 of 4 Updated 10/17/18
OFFICE COPY
In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the
Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation
instructions along with this Product Approval Sheet.
I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the
ones listed in this document must be approved by the Building Official.
4.)
*Contractor Name (Print Name):Cynthia Pa *Contractor Signature: fit, ;
*Company Name: Cache CO. LLC
*Mailing Address: 3616 Warrington Street
*City: Jacksonville *State: Fl *Zip Code: 32254
*Telephone Number: (904) 887-7663 *E-mail Address: Cindy@cachero0fing.com
Cell Phone Number: Fax Number:
Page 4 of 4 Updated 10/17/18
CBUCK Engineering OFFICE COPY
s:,3PC:;Ir1l1"t4 Sia it Jt—t{-1r irw.4
CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report
"M-Seam"
Metal Roof Assembly
Manufacturer:
Millennium Metals, Inc.
10200 Eastport Road
Jacksonville, FL 32218
(877) 358-7663
for
Florida Product Approval
# FL 5211.3 R7
Florida Building Code 6th Edition (2017)
Per Rule 61G20-3
Method: 1 - D
Category: Roofing
Sub - Category: Metal Roofing
Product: "M-Seam"
Material: Steel
Panel Thickness: 26 gauge, (Minimum)
Panel Width: 16" Facsimile of digital copy signed by
James L.Buckner,P.E.
Support: Wood Deck
Electronically signed and sealed documents shall
comply with the provisions of FAC Rule 61G15-23.
\\\\\I11I111/i/,,,
F'
Prepared by: �P.•'•\,\CENS •.•F,p
James L. Buckner, P.E., SECB _ * No 31242
Florida Professional Engineer # 31242 :3 * w.
Florida Evaluation ANE ID: 1916 STATE OF .•
Report No. 17-196-M-S6W-ER ��///7/ONA1.- \\\\\
(Revises 15-104-M-S6W-ER) I1I111\\
Date: 10/ 16/ 17
Contents:
Evaluation Report Pages 1 —7 2017.10.1920:13:36-04'00'
CBUCK,Inc.—Palm Beach County, Florida
Phone:(561)491-9927• Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net
Main Office: 1374 Community Drive,Jupiter, Florida 33458
FL#: FL 5211.3-R7
Date: 10/ 16/ 17
CBUCK Engineering Report No.: 27of M-S6W-ER
Specialty St ruck wal Entaineeving CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: Millennium Metals, Inc.
Product Name: "M-Seam"
Product Category: Roofing
Product Sub-Category Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product/System "M-Seam"
Description: 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with
screws.
Product Assembly as Refer to Page 4 of this report for product assembly components/materials&standards:
Evaluated:
1. Roof Panel
2. Fasteners
3. Underlayment
4. Insulation (Optional)
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of this
evaluation.)
Description:
• 15/32 (min.)or 19/32"or greater plywood,
• or Wood plank(min. specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable
code sections and in accordance with manufacturer's recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure: Refer to Table"A"
(Refer to"Table A" attachment details herein)
FL#: FL 5211.3-R7
Date: 10/16/ 17
CBUCKEngineering Report No.: 17-196-M-S6W-ER
Page 3 of 7
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Performance Standards: The product described herein has demonstrated compliance with:
• UL580-06—Test for Uplift Resistance of Roof Assemblies
• UL 1897-12—Uplift test for roof covering systems
Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is
equivalent to UL580-06 standard version adopted by the Florida Building Code 6th
Edition (2017).
• The UL 1897-98 standard version used to test the evaluated product assembly is
equivalent to UL1897-12 standard version adopted by the Florida Building Code 6th
Edition (2017).
Code Compliance: The product described herein has demonstrated compliance with Florida Building Code
6th Edition (2017),Section 1504.3.2.
Evaluation Report Scope: This product evaluation is limited to compliance with the structural requirements of the
Florida Building Code, as related to the scope section to Florida Product Approval Rule
61G20-3.001.
Limitations and •Scope of"Limitations and Conditions of Use"for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include "Limitations
and Conditions of Use" throughout the report in accordance with Rule 61G20-
3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to
approve products under"Optional Statewide Approval".
•Option for application outside"Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for"project specific approval by
the local authorities having jurisdiction in accordance with the alternate methods
and materials authorized in the Code". Any modification of the product as
evaluated in this report and approved by the Florida Building Commission is outside
the scope of this evaluation and will be the responsibility of others.
•This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to
comply with Florida product approval rule (FAC) 61620-3. This evaluation report is part
of the Florida Building Commission approval for the listed code related criteria. This
report by James Buckner, P.E. and CBUCK Engineering is not a design certification of
code compliance construction submittal documentation, per FBC section 107, for any
individual structure,site specific or permit design.
•All metal components and fasteners shall be corrosion resistant in accordance with
applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and
1507.4.4.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in
this evaluation.
•This evaluation report does not evaluate the use of this product for use in the High
Velocity Hurricane Zone code section. (Dade&Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance
with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certifications, Inc. (FBC Organization#:QUA 1824).
\ CBUCK Engineerings FL#:
Date: FL 5211.3-R
7
10/ 16/ 17
No.:P :rt
4of 7
Speciathy Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Components/Materials Roof Panel:
(by Manufacturer): Product Identification: M-Seam
Material: Steel
Thickness: 26 gauge Minimum
Panel Width: 16" (max.)Coverage
Rib Height: 1"
Yield Strength: 40 ksi min.
Corrosion Resistance: In compliance with FBC Section 1507.4.3:
• ASTM A792 coated, or
• ASTM A653 G90 galvanized steel
Fastener:
Type: Pancake-Head Wood Screw
Size: #10(x length to meet min. penetration through deck)
Penetration Through: 3/16" min.through wood deck
Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4
Standard: Per ANSI/ASME 818.6.4
Components/Materials Underlayment:
(by Others): Material and application shall be in compliance with FBC Section 1507.1.1 and in
accordance with applicable code sections and manufacturer's recommendations.
Insulation(Optional):
Type: Rigid Insulation Board
Thickness: 3" (max.)
Properties:
Density: 2.25 pcf(lbs/ft3) min.
Or Compressive Strength: 20 psi min.
Insulation Notes:
• Rigid Insulation shall meet minimum density OR compressive strength.
• Insulation shall comply with FBC Section 1508. When insulation is incorporated,
fastener length shall conform to penetrate thru bottom of support a minimum of
3/16".
FL#: FL 5211.3-R7
Date: 10/16/ 17
CBUCK Engineering Page rt No.: 57-1 6 M-S6W-ER
CBUCK,Inc.Certificate of Authorization t#8064
Specialty Structural Engineering
Installation: Installation Method:
(Refer to drawings on Pages 6-7 of this report.)
• Fastener spacing: Refer to Table"A"Below
(along the length of the panel)
• Rib Interlock: Snap Lock
(Panel ribs shall be fully engaged to form an integral interlock.)
• Minimum fastener penetration thru bottom of support,3/16".
• For panel construction at the end of panels, refer to manufacturer's instructions and
any site specific design.
TABLE"A"
ALLOWABLE LOADS
METHOD 1: METHOD 2:
* Design Pressure: -84.25 PSF -91.75 PSF
Deck Thickness: 15/32"or 19/32" 15/32"or 19/32"
Fastener Spacing: 8" 4"
*Allowable design pressure for allowable stress design(ASD)with a margin of
safety of 2 to 1.
Install the "M-Seam" roof panel assembly in compliance with the installation method
listed in this report and applicable code sections of FBC 6th Edition (2017). The
installation method described herein is in accordance with the scope of this evaluation
report. Refer to manufacturer's installation instructions as a supplemental guide for
attachment.
Referenced Data: 1. UL580-94& UL 1897-98 Uplift Test
By Hurricane Test Laboratory, LLC(FBC Organization#TST ID: 1527)
Report#: 0232-0508-05, Report Date: 6/29/05,Specimens#1-3
2. Quality Assurance
By Keystone Certifications, Inc. (QUA ID: 1824)
Millennium Metals Licensee#423
3. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
FL#: FL 5211.3-R7
Date: 10/ 16/ 17
CBUCK Engineering Page rt No.: 3.6o7 -M-S6W-ER
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Installation Method
Millennium Metals
"M-Seam" Roof Panel Attached to Wood Deck
Profile Drawings
1"
j____ L.....0 - 16'Cover 0I
I
1 1
_ 1I-
co Striatials 3/4
Type:Ancil Rib a Striated
Typical Panel Profile View (Not To Scale)
16"o.c.
<---- ' ___ -1-_-_—_-_---- ---------------- —--- ----- _____ ,
411 i _. Integral Snap Lock
#10 Pancake-Head Screw
_ 3/16'min. penetration thru deck
i
MA
Typical Assembly Profile View (Not To Scale)
FL#: FL 5211.3-R7
Date: 10/ 16/ 17
CHUCK Engineering Page::rt
No.: ;7-1 M-196 -ER
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Installation Method
Millennium Metals
"M-Seam" Roof Panel Attached to Wood Deck
Fastener:
#10 Pancake-Head Screw—-
M,Sear�i'RnOf Pard r------- —
/ •'
; 8"o.c Typical
/
Support: �--------Insulation:
-15/32"or 19/32"CDX Plywood Deck,or (Optional)3"max or 25 psi min.
-Mod plank
Typical Assembly Profile View (Not To Scale)
TABLE "A"
ALLOWABLE LOADS -
METHOD 1: METHOD 2:
* Design Pressure: -84.25 PSF -91.75 PSF
Deck Thickness: 15/32" or 19/32" 15/32"or 19/32"
Fastener Spacing: 8" 4"
*Allowable design pressure for allowable stress design(ASD)with a margin of
safety of 2 to 1.
MILLENNIUM
Arth METALS, INC. OFFICE COPY
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
Net Coverage 1 6" Nominal
„__„PANEL PROFILE
DIMPLE APROX.
EVERY 4' 0.C.
STARTER/END
/ SLOT APROX. 2”
FROM PANEL
ENDS
/� 4 � 2.t
Sidelap Detail Nailstrip Detail
NOTES:
1 . M-Seam Panels are only available with minor ribs to reduce oil
canning.
2.Oil canning is inherent to all metal panels and therefore is not
considered a manufacturers defect nor a warranty condition.
3.Consult your contractor immediately if you need information
concering this condition.
Gauge Finishes Nominal Thickness ASTM & Grade Specifications
26 Acrylic Galvalume .0179 ASTM A-792 AZ55
26 PTD Galvalume * .0179 ASTM A-792 AZ55
24 Acrylic Galvalume .0240 ASTM A-792 AZ55
PTD Galvalume is 70%Kynar 500 or Hylar 5000 PVDF Resin unless otherwise indicated.
Millennium Metals Offers a Limited 25 year warranty on Painted Panels,20 year limited warranty on Mill Finished Acrylume Panels.
Please request warranty information from your distributor.
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
M-Seam Installation Instructions:
Panel Attachment: M-Seam recommended attachment is 8" on center along the edge of the nailer strip.
This attachment may not be suitable for all applications. Projects may require an engineer to evaluate
conditions such as mean height, exposure type, and roof configuration as indicated in ASCE 7-98 and
ASCE 7-02. Additional fasteners may be required along the end zones on the panel (eave, ridge, and
perimeter).
Pitch Alert: This product should not be used on applications less than a 2/12 pitch.
Roof Application:
Step 1: Make sure deck is even and square.
Step 2: Panel should begin on the gable end opposite of the prevailing wind. Begin with the receiving
edge of panel (female side) along the Gable (see Gable Rake Detail). The edge away from the Gable
should be the nailstrip. After checking that the panel is square to the eave, make sure the panel is
attached as indicated in panel attachment(see above) and also 2" from the leading and trailing end of
the panel on the nailstrip. The screw should be placed in the center of the nailstrip slot provided.
Sealant is recommended on applications less than a 3/12 pitch.
Step 3: After attaching the first panel completely, panel 2 should be snapped in place using a rubber
mallet. A minimum of 1" overhang is recommended at the eave. Typical eave detail requires the use
of a hemming tool to hem the panel over the ED2 (detail has 1-1/2" overhang).
Install the remaining accessories. Millennium Metals offers a variety of products such as pipe boots,
butyl tape, and ventilation materials. Do not use copper or lead products in conjunction with M-Seam
as it will void the warranty.
ATTENTION INSTALLER: PLEASE REFER TO THE IMPORTANT NOTE SECTION OF THIS
MANUAL FOR SAFETY, STORAGE, OIL CANNING DISCLAIMER, AND SHAVING
DISCLAIMER PRIOR TO BEGINNING PROJECT.
Code requirements vary from area to area and job type as well as roof configuration. Job specific
engineering is not a service provided by Millennium Metals. Estimates/Takeoffs are provided at a
nominal fee for materials only. It is the sole responsibility of the customer to review the takeoff and
make any changes to the quantity, length or accessories he/she feels necessary. Millennium Metals
takes no responsibility as to the accuracy of the information provided.
M-Seam is a special order product and therefore is not returnable. Please verify all items prior to
ordering.
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 2
MILLENNIUM
METALS , INC .
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
Important Notes:
Millennium Metals recommends licensed roofing professionals to install our materials. Please
use gloves, glasses, and other protection when handling material to prevent injury. It is
necessary to inspect deck integrity to insure it is safe to walk on before beginning any work.
Millennium Metals recommends all installers follow the OSHA requirement for fall protection.
Never walk on materials when wet or when unsuitable weather conditions are present.
Storage:
Materials should be installed immediately. Any unused materials should be stored in a dry
place where moisture will not reach and penetrate bundles. Material should always be placed
on wood block to separate from the ground or concrete. Do not cover with plastic!!! Instead,
use loose canvas tarps so that air can circulate. Cut the bands so that the material can expand.
Millennium Metals warrants the material only. We do not offer weather tightness warranties.
Any such warranty is up to the contractor to include in their contract.
Decking:
Millennium Metals recommends the use of minimum 1/2" plywood or OSB Board attached in
accordance with code. The deck must be supported by an engineered truss system not to exceed
24" on center. A moisture barrier such as 30# felt or other ASTM approved underlayment
should be used over decking to control moisture. Metal should never come in direct contact
with green or pressure treated lumber as it will cause corrosion. If tin tabs are required to attach
felt it will be necessary to apply a 15# felt in the direction of the panel as an additional
separation barrier. M-seam is recommended on application with 2-1/2/ 12 or greater.
Oil Canning Disclaimer:
Oil canning is industry wide and inherit to all metal panels. It is more visible in designs with
flat spans as with this panel. Oil canning is a wavy appearance in the surface of the metal panel.
This slight distortion in no way effects the warranty nor is a reason for rejection or refusal.
Shavings Disclaimer:
When using fasteners to penetrate steel sheets the iron particles tend to go airborne and settle
on the sheet. It is necessary to remove these particles to prevent embedment and rust marks.
MILLENNIUM METALS INC.
TOLL FREE: 1 -877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 3
MILLENNIUM
AINMETALS, INC. M-SEAM DETAIL LOCATIONS
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
SR-1
RC-10 GR-9
RC 15 RAKE EDGE
SW-3 RIDGE �,,.. PAGE 8
PAGE 6 --
SW-4 ,
Do SIDEWALL =
0 PAGE 10 F TF-2
o j — TRANSITION
EW-3 _ _ PAGE 9
Z ENDWALL
m PAGE 11 _--
____ ________-> 4 110.‘14: 0 ��-
HS-1 ` � `�
HIGH SIDE EAVE IV‘1
�/
PAGE 7 _ •
ice" \ %,,01,44,,, ill
,�
. A
,., -
r / 4 .
�--.4
;,IIEl ,,,
ED-2 PANEL PROFILE
PAGE1
„ ,.. - 1
4
EAVE DRIP
PAGE 7
SW-4 or SW-3 PV-3 RC-10
g SIDEWALL VALLEY HIP
m PAGE 10 PAGE 9 PAGE 6
4,
MILLENNIUM
Artta METALS , INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
1. SAVE DRIP (EF-5) 2. ENDWALL FLASHING (FW-3) 3. EXTENDED EAVE (ED-2) 3. EXTENDED EAVE (ED-2R)
J 3 3/D PAINT S 3/8, PAINT 4 3/4" PAINT
`� _ PAINT
,/N
N x 5/8' '' 4 1/2 2 1/2"
1 1/2"
"----.7:V1 1/2"
1/2J� — �C�S/8"
x 5/8"
1/
OVERHANG: 1-3" OVERHANG: 1-3"
4. GABLE RAKE (GR-9) 4. GABLE_RAKE (GR-9R) 5. GAMBREL FLASHING (GF-2) 6. HIGHSIDE EAVE (HS-1)
3-1/8" 3-1/4" y
7-1/4" � 1�
"
-cl +F 1:.,
5/8 7 GGG \
M 5/8")5p2• )5CX1/2"
J 5/8" a _ "JC
5/8"�( /� 1/2"
1/ 'X 2" 5/8 (
7. HIP CAP (RC-10) 8. J–CHANNEL (JC-7) 9. PREFORMED VALLEY (PV-3) 10. STEP SIDEWALL (SW-4)
5,55 4-1/2" 9-'1/ •.
M
–3/8"
\\ 1"
1-3/8" 2-7/8" II 5/8"
1"
11. TRANSITION FLASHING (TF-2) 12. SIDEWALL FLASHING (SW-3) 13. STEP RAKE (SR-1) 14. COUNTER FLASHING (CF-1)
1/2">(
3"
1'
co
g, 6" M 3-3/8" N
1-1/16"
M I II \ x 3/4.
'1 - 41/2" 1/2"1 M 25( 5/8" U1/2"
�c
3/4"
15. RIDGE CAP (RC-20) CLEAT OFFSET CLEAT (CL-2) Z–CLOSURE (ZC-1) REGLET FLASHING CRF-1)
1" 1/2„
6,117:. 1-1/2" 1" 1--IL
LO
N �( I' I
TTTT \
- 1*
M
I
L N
1 3/8" 1 I L
FLASHING PROFILES
MILLENNIUM METALS INC.
TOLL FREE: 1 -877-358-7663
FAX.904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 5
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
STITCH SCREWS
0 12" O.C., DO NOT OVERDRIVE
RIDGE CAP _= M-SEAM PANEL
VENTING
MATERIAL
30# FELT
ATTACHED PER CODE
APPROVED SOLID SUBSTRATE
VENTED RIDGE DETAIL RC- 15
•
4410V:441
M-SEAM PANEL
S.S. POP RIVETS
"Z" CLOSURE CUT TO FIT BETWEEN
PANEL, (3) #10-12 X 1" PANCAKE
HEAD SCREWS PER PANEL
CONT. BUTYL TAPE SEALANT
APPROVED SOLID SUBSTRATE
#30 FELT
ATTACHED PER CODE
HIP/RIDGE FLASHING
RIDGE CAP RC- 10/RC-20
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 6
MILLENNIUM
411t4 METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
0
M-SEAM HEMMED
® SEE DETAIL FOR HEMMING
#10-12 X 1" PANCAKE PANEL PAGE 3
.•01
HEAD SCREWS ® 12" O.C.
M-SEAM PANEL
#30 FELT
ATTACHED PER CODE
APPROVED SOLID SUBSTRATE
CLEAT IN/ #10-12 X 1"
PANCAKE HEAD SCREW 0 12" O.C.
FASCIA BOARD
EAVE DRIP DETAIL ED-2 EAVE FLASHING PANEL DETAIL MAKE IT FLUSH AND SHORT TO DEPICT
HOLE.
S.S. POP RIVETS
M-SEAM PANEL 0 12" 0.C.
HIGH-SIDE EAVE
FLASHING
"Z" CLOSURE CUT TO FIT BETWEEN
PANEL, (3) #10-12 X 1"
PANCAKE HEAD SCREW PER PANEL
irriAlr A
APPROVED SOLID
SUBSTRATE
#30 FELT
ATTACHED PER CODE
CLEAT W/
#10-12 X 1" PANCAKE
HEAD SCREWS ® 12" O.C.
CONT. BUTYL
TAPE SEALANT
HIGHSIDE EAVE DETAIL HS- 1
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX.904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 7
MILLENNIUM
oilltia METALS , INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
/,*/rrr// �, S EN D
-714. ,
wi,n/i/*iir�rrr _
%, v ,--
lIb
fir
14141,.
FIELD BEND
PANEL 1" MIN.
1.
////// CONT. BATYL
LAN
TAPE SEALANT
STITCH SCREWS
. "'/ 0 12' O.C.
' 11�ii�
301 FELT ATTACHED PER CODE
1 STITCH SCREWS 0 12" O.C.
M-SEAM PANEL
,''1,44i CONT. BUTYLTAPE SEALANT
,,+r//'/r/ STEP GABLE FLASHING
STAT /%5 APPROVED SOLID SUBSTRATE
FASCIA
CLEAT W/#10-12 X 1"
STEP GABLE RAKE DETAIL SR- 1 PANCAKE HEAD SCREWS
/.//,�//,�//'. 4 E N D
/./i/�r//.r
//wi It/,.,, i//, FIELD BEND
/l// PANEL 1" MIN.
CONT. BUM
TAPE SEALANT
it 'Z" CLOSURE
�/ GABLE FLASHING
STITCH SCREWS
o4.P*
130 FELT
O 12" O.C.
`-. ATTACHED PER CODE
I11r Il APPROVED SOLID SUBSTRATE
`�� /� M-SEAM PANEL
i
® it_/i "Z" CLOSURE CUT TO FiT BETWEEN PANEL,
(3) #12 X 1 WHS PER PANEL
STA T i` CONT. BUM TAPE SEALANT
FASCIA
CLEAT W/ #10-12 X 1"
PANCAKE HEAD SCREWS
GABLE RAKE DETAIL GR-9
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 8
MILLENNIUM
isillt4 METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
ik
/;
H.. sr .
N-SEAM PANEL
#30 FELT
ATTACHED PER CODE
-VALLEY FLASHING APPROVED SOLID SUBSTRATE
CLEAT SET IN BUTYL TAPE CONT. BUTYL
SEALANT W/ #10-12 X 1" TAPE SEALANT
PANCAKE HEAD SCREWS 6" O.C.
PREFORMED VALLEY DETAIL PV-3
OFFSET CLEAT SET IN
BUTYL
TAPE SEALANT
W/ #10-12 X 1" PANCAKE O
HEAD SCREWS 0 12" O.C. ��-
•
TRANSITION
FLASHING
S.S. POP RIVETS
0 12" O.C.
.`►I
fr♦•✓P
10
CONT. BUM TAPE SEALANT
7" CLOSURE CUT TO FIT BETWEEN
PANEL, (3) #10-12 X 1" PANCAKE
SCREWS PER PANEL
M-SEAM PANEL
30# FELT
ATTACHED PER CODE
APPROVED SOLID SUBSTRATE
TRANSITION DETAIL
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 9
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
SEALANT
CONT. BUTYL
SEALANT TAPE SEALANT
SURFACE-MOUNT
CONT. BUTYL TAPE COUNTER FLASHING � � _
(.
SEALANT 1:. SIDEWALL FLASHING
® S.S. POP RIVET ,�, 1
COUNTER FLASHING I ® 12" O.C. �'
"Z" CLOSURE CUT TO FIT .
STEP SIDEWALL BETWEEN PANEL, (3) #12 X 1
FLASHING PANCAKE SCREWS PER PANEL
#30 FELT
ATTACHED
PER CODE CONT. BUTYL TAPE
APPROVED SOLID-- � SEALANT
SUBSTRATE 41111114b..4\. #30 FELT /Iq#A. '1111iSTITCH SCREWSATTACHED PER CODE 4#464.
441
• 12" O.C. APPROVED SOLID
CONT. BUTYL TAPE SUBSTRATE
SEALANT M-SEAM PANEL
M-SEAM PANEL
SIDEWALL FLASHING DETAIL SW-3 & SW-4
SIDING/STUCCO ...11111111
SEALANT ��' SEALANT Apt-
z.hr
H� CONT. BUTYL �;i Pe
REGLET ` �� TAPE SEALANT
FLASHING �.
i
FLASHING
SAW CUT CONT. BUTYL /
llriP14
I
TAPE SEALANT
SIDEWALL FLASHING ir% i
CONT. BUTYL
TAPE SEALANT
MASONARY WALL
STEP SIDEWALL
FLASHING
SIDEWALL COUNTER FLASHING OPTIONS
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 10
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
.E; Co
I!.
IDSEALANT jib ;
CONT. BUTYL
TAPE SEALANT
SURFACE MOUNT
COUNTER FLASHING
HEADWALL FLASHING
tAL\* '76
CAULK 0 ALL SEAMS
N ...........#PP
CONT. BUTYL TAPE SEALANT •*
"Z" CLOSURE CUT TO FIT BETWEEN
PANEL, (3) #10-12 X 1" PANCAKE
HEAD SCREWS PER PANEL Ni
S.S. POP RIVETS 'Q
M-SEAM PANEL
APPROVED SOLID SUBSTRATE //���/"
#30 FELT ATTACHED PER CODE -i //"
ENDWALL DETAIL EW-3
SIDING/STUCCO _,
SEALANT ��� SEALANTArp41
1���,�''�♦��� CONT. BUTYL �•
REGLET
41111W9,1-
�� TAPE SEALANT 1i.P -
FLASHING �.
iv
FLASHING
SAW CUT Oil CONT. BUTYL iPPPP
i.dSIDEWALL
TAPE SEALANT
CONT. BUTYLTAPE SEALANT FLASHING
MASONARY WALL
STEP SIDEWALL
FLASHING
ENDWALL COUNTER FLASHING OPTIONS
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 11
MILLENNIUM
oilltta METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
PANEL HEMMING
L�
_ , A
7 - ,
, ::-.......cD''
!, S !!!
•
;c,
J���� %
S
...,_.. II
,b
..4,..
....... ,,,,„ ...
....
CAULK
CUT PANEL BACK 1 i" TO
CREATE HEM. USE HEMMING TOOL.
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 12
CITY OF ATLANTIC BEACH BUILDING DEPARTMENT
(' ' - ) 800 SEMINOLE ROAD
(----
' Y _' ATLANTIC BEACH, FL 32233
�Jiil9%
CERTIFICATE OF COMPLETION
ROOF19-0078
ROOF NON SHINGLE
ISSUED: JOB ADDRESS: REAL ESTATE NUMBER: ZONING:
2/14/2020 1596 MARITIME OAK DR 169505 1975
DESCRIPTION OF WORK:
METAL ROOF
OWNER: CONTRACTOR:
ZALUPSKI CHRISTOPHER E CACHE CO LLC
633 W 46TH ST
JACKSONVILLE, FL 32208
APPROVED: DI k-----4. glir°A
CHIEF BUILDING OFFICIAL
VOID UNLESS SIGNED BY BUILDING OFFICIAL