Loading...
1735 Maritime Oak Dr ROOF19-0084 Metal Roof ROOF NON SHINGLE PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROOF19-0084 u ISSUED: 11/25/2019 800 SEMINOLE ROAD ps:19r ATLANTIC BEACH. FL 32233 EXPIRES: 5/23/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1735 MARITIME OAKS DR ROOF NON SHINGLE METALL ROOFS OVER $5100.00 PORCH AND SHED AREAS TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: COMPANY: ADDRESS: CITY: STATE: ZIP: TOP GUN ROOFING, INC. 5570 FLORIDA MINING BLVD JACKSONVILLE FL 32257 OWNER: ADDRESS: CITY: STATE: ZIP: RUNQUIST ERIC WILLIAM 1735 MARITIME OAKS DR ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. • LIST OF CONDITIONS Roll off container company must be on City approved list. Container cannot be placed on City right-of-way. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL:$124.00 Issued Date: 11/25/2019 1 of 2 rs'd1i‘1'"',, ROOF NON SHINGLE PERMIT PERMIT NUMBER ,, . CITY OF ATLANTIC BEACH ROOF19-0084 r 800 SEMINOLE ROAD ISSUED: 11/25/2019 °`?- ,'3 vATLANTIC BEACH, FL 32233 EXPIRES: 5/23/2020 Issued Date: 11/25/2019 2 of 2 Sr.v.t City of Atlantic Beach APPLICATION NUMBER �� 00 Building Department (To be assigned by the Building Department.) 800 Seminole Road �Q� I -0084-- v-,.,,.... �r� /( 0 Atlantic Beach, Florida 32233-5445 1 V `t / Phone(904)247-5826 - Fax(904)247-5845 / �o;� fir/ E-mail: building-dept@coab.us Date routed l I City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: ar(, VY\ 1,1____pepartment review required Yes No <Buildin TbApplicant: t ("7-AL) � F1k�' Planning &Zoning Tree Administrator Project: ( V\ &r&C- 2 00 c- Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1-4proved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDIN PLANNING &ZONING Reviewed by: ill Date: it 0 et/9 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denie . ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ; r rimming rermit Application Updated10/9/18 If- -: ',1 City of Atlantic Beach Building Department OFFICE COF **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY ' �' IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 1735 MARITIME OAKS DRIVE Permit Number: 1RCF (9 'C, rc) -{- Legal Description 67-132 08-2S-29E .22 ATLANTIC BEACH COUNTRY CLUB UNIT 2 LOT 98 RE# 169505-1785 Valuation of Work(Replacement Cost)$ 5,100.00 Heated/Cooled SF Non-Heated/Cooled • Class of Work: New ❑Addition DAlteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial ©Residential • If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No • Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) ❑No Describe in detail the type of work to be performed: ,',i' ,,,.,j IA 1-004 oo _[' 0 _ / _ A_�l METAL PORCH & 2 SHED ROOFS -3 1 V �' f , ��r z cn r l Z 1 L ( t, Florida Product Approval# FL11651.23 METAL& FL14317.1 UNDERLAYMENT for multiple products use product appruivalio t0 1= \ Property Owner Information n w O o ti.i Name ERIC &AMANDA RINQUIST Address 1735 MARITIME OAK DRIVE o m p q F City AE LANTIC BEACH State FL Zip 32233 _Phone 323.8264 W U U Q E-Mail ClzrCz Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) 0 Q 0 a Contractor Information U H N H tf Z Name of Company TOP GUN ROOFING INC. Qualifying Agent MATT P MCLEOD 0 2 w Address 5570 FLORIDA MINING BLVD SOUTH#501 City JAX State FL Zip 322571.L 0 w 2 Office Phone 904-342-0211 Job Site Contact Number 904-509-2595 H w - 0 State Certification/Registration# CCC058178 E-Mail OFFICE@TOPGUNROOFING.NET — w p w Architect Name&Phone# W U `niu W cc Engineer's Name& Phone# j W Workers Compensation Insurer FRSA 870-033663 OR Exempt❑ Expiration Date 12/31719 CC OC Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: Ina di o t to. r r7`u'It7 te(Itsof� permit,there may be additional restrictions applicable to this property that may be found in the publicreco•rds'c(.th4cc}uniy:a,,d.•; there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. nn'',, OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done iNL�dmpligc2Q $1 all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A ► : ICE OF CO! MENCTMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVE ' TS TO YOUR ' ' •PE' . IF`YOU INTEND TO OBTAIN;FINANCING, CONSULT WITH YOU ' ENDER OR AN I TTO ' N Y : . ORE RECORDING YOUR NOTICE OF MMENCEM , ► II" ,p % 111 (Signature of Owner or Agent) (Signature of Contractor) Signed and sworn to(or affirmed)before me this`�day of Signed •and sworn to(or affirmed)before me this\2day of 1 \)1Q(1\\101, a-ov--\, by d" Ate'. PC (.,e—d\ \QciArls-C, \\ , •y ... \moi (Signature of Notary). (Signature of Notary) 4 k-..vole.. TERESA STONE IRWIN I f?.(• �': Notary Public-State of Florida Y n •.,. �<' I ersonall �� �e TERESA STONE IRWIN Personally Known OR o; Commission GG 31 t 787 y Known OR _° :9� �: I ���.� NotaryPublic-State of Florida [ ]Pr duced Identification orr`...` My Comm.spires Jul 8,2023 [ ] Produced Identification y<: @: Commission 4 GG 311787 Type of Identification: 4 Bonded through National Notary Assn. Type of Identification: `-ror rs M ,1111 ., - _ , Bonded through National Notary Assn. OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: 1735 MARITIME OAKS DRIVE ATLANTIC BEACH, FL 32233 1 �0 Permit#: gOO-1 7 G — ff ERIC &AMANDA RINQUIST *Owner/Project Name: As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s)for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 1 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1. Siding OFFICE A 2. Soffits COPY 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments BORAL PEEL & STICK FL14317.1 3. Roofing fasteners 4. Nonstructural metal GULF COAST SUPPLY GULF RIB FL11651.23 roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 10/17/18 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building OfficiOFFICE COPY *Contractor Name (Print Name): \� *Contractor Signature: *Company Name:--C-C: ‘? ��� v�C - *Mailing Address: S�� �o� �c� 0.— �����r �vC�. � ��,, ��\ *City: 3 rnL� s>U���L *State: L *Zip Code: *Telephone Number: ���� �`\�—Q \\ *E-mail Address: vk rfi Cell Phone Number: (-3\16� SOQI- Fax Number: Page 4 of 4 Updated 10/17/18 OFFICE COPY Business & Professional Regulation BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats& Facts Publications F )Product Approval USER: Public User Lr Product Approval Menu > Product or Application Search > Application List > Application Detail s FL # FL14317-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Boral Roofing / MonierLifetile Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (602) 269-2288 Ext 8320 thomas.jemmett@boral.com Authorized Signature Thomas Jemmett thomas.jemmett@boral.com Technical Representative Adrian Cooper Address/Phone/Email 135 NW 20th Street Boca Raton, FL 33431 (954) 520-5461 acoopeer@minierlifetile.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Regis Professional Engineer Evaluation Report - Hardcopy Recei' Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/21/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Rec! Certificate of Independence FL14317 R8 COI 2015 01 COI Mem Referenced Standard and Year (of Standard) Standard ASTM D1970 FRSA/TRI (April 2012) 04-12 UL 1897 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/14/2017 Date Validated 10/16/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary_of Products FL # Model, Number or Name Description 14317.1 Boral Roof Underlayments Roof underlayments for use in prey Limits of Use Installation Instructions Approved for use in HVHZ: No FL14317 R8 II 2017 10 FINAL Approved for use outside HVHZ: Yes R8,pdf Impact Resistant: N/A Verified By: Robert 3. M. Nieminei Design Pressure: +N/A/-202.5 Created by Independent Third Par Other: 1.) The design pressure in this application Evaluation Reports pertains to a particular underlayment system for use FL14317 R8 AE 2017 10 FINAL under foam-on tile systems. Refer to ER Section 5.6.2 for R8,pdf all such systems and max design pressures. 2.) Refer to Created by Independent Third Par ER Section 5 for Limits of Use. 1 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-44 The State of Florida is an AA/EEO employer. CoRy_[i.ght 2007-2013 State of Florida. :: Privacy Statement :: Under Florida law, email addresses are public records. If you do not want your e-mail address released in resp( electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questior Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. r address if they have one. The emails provided may be used for official communication with the licensee. Howevc not wish to supply a personal address, please provide the Department with an email address which can be mad are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY' ERIC 353 CHRISTIAN STREET, UNIT#13 OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Bora!Roofing Evaluation Report M35710.12.10-R9 7575 Irvine Center Drive,Suite 100 FL14317-R8 Irvine,CA.92618 Date of Issuance:12/21/2010 (602)269-2288 Revision 9:10/14/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: :,�,t.,.,, OF �T. ' fi Robert J.M.Nieminen,P.E. j The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 ' Nieminen,P.E.on 10/14/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Boral Roof Underlayments,as marketed by Boral Roofing, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD(TST 6049) Physical Properties M36790.07.11 09/30/2011 ERD(TST 6049) Physical Properties 640380.08.12 08/28/2012 ERD(TST 6049) Tensile Adhesion/LTA C41420.09.12-2 09/11/2012 ERD(TST 6049) Adhesion 641940.09.12 09/13/2012 ERD(TST 6049) Tensile Adhesion/LTA 847390.07.14-1 07/31/2014 ERD(TST 6049) Tensile Adhesion/LTA 1347390.09.14 09/04/2014 PRI(TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI(TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI(TST 5878) Tensile Adhesion/LTA NEI-046-02-01REV 12/17/2010 PRI(TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI(TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 UL,LLC.(QUA 9625) Quality Assurance Service Confirmation Exp.08/21/2020 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering Underlayments: 4.1.1 Boral TileSeal.50"T is a nominal 50-mil thick,polyester-surfaced,self-adhering SBS modified bitumen roof underlayment;meets ASTM D1970. 4.1.2 Boral TileSeal® 'rr is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI 04-12. 4.1.3 GatorSeal® is a nominal SS-mil thick, granular-surfaced, fiberglass reinforced, self-adhering SBS modified bitumen roof underlayment;meets ASTM 01970. 4.1.4 Citadel Plus is a nominal 48-mil thick, fabric-surfaced, fiberglass reinforced, self-adhering SBS modified bitumen roofing underlayment for use as a base-layer in two-ply underlayment systems; meets ASTM 01970. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity'ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design,LLC, Evaluation Report M35710.12.10-R9 Certificate of Authorization#9503 6m EDITION(2017)FBC NON-HVHZ EVALUATION F114317-R8 Bora!Roof Underlayments;(602)269-2288 Revision 9:10/14/2017 Page 2of7 TRINITY ERD 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof covers. Refer to the installation instructions and Table 2 for two-ply underlayment options. TABLE 1: ROOF COVER OPTIONS Asphalt ! Adhesive set Wood Shakes Underlayment Shingles Nail-On Tile Tile Metal &Shingles Slate Boral TileSeal 50"' Yes No No Yes Yes Yes Bora'TileSear Yes Yes Yes Yes Yes Yes (See 5.5.1) GatorSeal Yes No No No Yes Yes 5.5.1 "Adhesive-set Tile"is limited to use of following Approved tile adhesives/underlayment combinations. TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS1 Adhesive Florida Product Approval Underlayments DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FL14506 Boral TileSeal"T Dow TILE BOND'"Roof Tile Adhesive FL22525 Boral TileSeal ICP Adhesives Polysete AH-160 FL6332 Boral TileSeai"T ICP Adhesives Palysete RTA-1 FL6276 Boral TileSeal"' 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Citadel Plus, Boral TileSeal 50"T,Boral TileSeal"T or GatorSeal: Plywood(unprimed or primed with ASTM D41 primer). Boral TileSeal"T: OSB primed with ASTM D41 primer. Note: Refer to Section 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the overlying roof cover is adhesive-set tile roofing 5.6.2 Bond to Base Laver Underlayment: Citadel Plus, Boral TileSeal 50HT, Boral TileSeal"T or GatorSeal: ASTM D226,Type Il felt;Citadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive-set tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in accordance with FBC 1504.3.1. Refer to file Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design,LLC, Evaluation Report M35710.12.10-R9 Certificate ojAuthorizatlon#9503 6 EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-R8 Boral Roof Underlayments;(602)269-2288 Revision 9:10/14/2017 Page 3 of 7 TRINITY ERD 5.6.3 Bond to Other Substrate Types: Citadel Pius,Boral TileSeal 508T, Boral TileSeal"r or GatorSeal: ASTM D41 primed metal(e.g.,flashing metal,valley metal,etc). Boral TileSeal"r: Huber Zip Deck(unprimed or primed with ASTM D41 primer);Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.6.4 Wind Resistance for Underlayment Systems in Adhesive-set Tile Applications: FRSA/TRI April 2012(04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive-set tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in adhesive-set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure=-105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: (Optional)Citadel Plus,self-adhered Underlayment: Boral TileSeal"r, self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1'A"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure=-120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM 041 to the plywood deck Base Ply: Citadel Plus,self-adhered Cap Sheet: Bora! TileSealHT, self-adhered, and back-nailed within the selvedge-edge side laps using 12 ga.x 1'/4"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM 041 to the plywood deck Base Ply: None Cap Sheet: Boral TileSealHT, self-adhered, and back-nailed within the selvedge-edge side laps using 12 ga.x 1A"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM 041 to the concrete deck Base Ply: (Optional)Citadel Plus,self-adhered Cap Sheet: Bora!TileSeal' ,self-adhered 5.6.4.1 Note: For adhesive-set tile systems, if there is a base ply or mid-ply of Citadel Plus in the system, the project design pressure requirements may not exceed-120 psf. Exterior Research and Design,LLC. Evaluation Report M35710.12.10-R9 Certlflrate of Authorization 89503 6'"EDITION(2017)F8C NON-HVHZ EVALUATION FL14317•R8 floral Roof Underlayments;(602)269-2288 Revision 9:10/14/2017 Page 4 of 7 TRINITY ERCP 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover. Boral TileSeal 50HT and Boral TileSeai' shall not be left exposed for longer than 180-days after installation,prior to placement of final roof cover. Citadel Plus,for use as a base-layer in a two-ply underlayment system,shall not be left exposed for longer than 180-days after installation,prior to placement of subsequent underlayment layer. 5.8 Tile Slippage Limitations(FRSA/TRI April 2012(04-12)1: When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Stagging Method Maximum Slope Boral TileSeal"' Flat Max,10-tile stack 6:12 Lugged Max.10-tile stack 6:12 6. INSTALLATION: 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 40'F and rising. 6.4 Citadel Plus: 6.4.1 Citadel Plus is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50"T,Borai TileSeal"T or GatorSeal. 6.4.2 Slope limitations are those associated with the top-layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge, extending over by'/,-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails&tin-tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses minimum 2 inches (horizontal lap) and minimum 4" end(vertical)laps. Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 50"T Boral TileSeai"T or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi-ply system. Install optional Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 50HT, Bora'TileSeai"T or GatorSeal. Exterior Research and Design,LLC, Evaluation Report M35710.12.10-R9 Certyicate of Authorization#9503 6'''EDITION 120171 FBC NDN-NVI4Z EVALUATION FL13317-R8 Boral Roof Underlayments;(602)269-2288 Revision 9:10/14/2017 Page 5 of 7 TRINITY ERD Note: For adhesive-set tile systems, if there is a base ply or mid-ply of Citadel Plus in the system, the project design pressure requirements may not exceed-120 psf. 6.5 Boral TileSeal 50Rr: 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 50RT on roof pitches less than 2:12. 6.5.3 Non-Tile Applications,Direct to Deck: Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the black selvedge edge to the deck with roofing nails,nails&tin-tags or 1- inch diameter plastic or steel cap nails spaced 24-inch o.c.for slopes below 7:12 and 12-inch o.c.for slopes 7:12 and greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. 6.5.4 Non-Tile Applications,to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal SOHT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published installation instructions and Section 6.5.3,except end(vertical)laps,described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface,rolling the interface into place with a weighted roller. 6.6 GatorSeal: 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non-Tile applications,Direct to Deck: Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the black selvedge edge to the deck with roofing nails,nails&tin-tags or 1- inch diameter plastic or steel cap nails spaced 24-inch o.c.for slopes below 7:12 and 12-inch o.c.for slopes 7:12 and greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self- adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non-Tile Applications,to Base Sheet: Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end(vertical)laps,described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the granular top surface,rolling the interface into place with a weighted roller. Exterior Research and Design,LLC, Evaluation Report M35710.12.10-R9 Certificate of Authorization 09503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F114317-R8 Boral Roof Underlayments;(602)269-2288 Revision 9:10/14/2017 Page 6 of 7 TRINITY ERD 6.7 Boral TileSeal HT: 6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSeal HI on roof pitches less than 2:12. 6.7.3 Non-Tile Applications,Direct to Deck: For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by s-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the black selvedge edge to the deck with roofing nails,nails&tin-tags or 1- inch diameter plastic or steel cap nails spaced 24-inch o.c.for slopes below 7:12 and 12-inch o.c.for slopes 7:12 and greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. 6.7.4 Non-Tile Applications,to Base Sheet: Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal HT over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3,except end(vertical)laps,described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface,rolling the interface into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self-adhering top sheet(s),Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.4 herein. Note: For adhesive-set tile systems, if there is a base ply or mid-ply of Citadel Plus in the system, the project design pressure requirements may not exceed-120 psf. Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal HT with roof pitches of 21.4 to less than 3:12. Boral Roofing's Elevated Batten System or counter battens are required. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Brentwood,NH 9. QUALITY ASSURANCE ENTITY: UL,LLC.—QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania(caul.com -END OF EVALUATION REPORT- Exterior Research and Design,LLC, Evaluation Report M35710.12.10-R9 Certificate of Authorization#9503 6,,,EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-R8 Boral Roof Underlayments;(602)269-2288 Revision 9:10/14/2017 Page 7 of 7 11/12/2019 Florida Building Code Online PuORrOA OepAPINVIV OFFICE COPY.. :-" Business & Professional Regulation Illasimaismatiamormin BCIS Home Log In i User Registration i Ho,Topics Submit Surcharge ; Stats&Facts I Publications f Contact Us IBCIS Site Map Links Search dFI Iida Product Approval USER:Public User Product Approval Menu>Product or Application frch>Appiication Ust>Application Detail ►OFFiCCE AF Tt4E FL# FL11651-R3 SECRETARY Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Gulf Coast Supply&Manufacturing, LLC. Address/Phone/Email 4020 S. W.449th Street Horseshoe Beach, FL 32648 (352)498-0778 info@gulfcoastsupply.com Authorized Signature Eng David info@gulfcoastsupply.com Technical Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 info@gulfcoastsupply.com Quality Assurance Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 david.eng@gulfcoastsupply.com Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Daniel S. Kuhn Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09.p Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 haps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d I/3 iii 1L/Lu19 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products Go to Page ® • Page 2/2• • FL# Model, Number or Name Description 11651.21 26 Ga.Gu fRib Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 21 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes 19n1.1 Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes Other: -109.25 psf @ 24"o.c.fasteier spacing. -164.25 psf @ Evaluation Reports 12"fastener spacing.Install per manufacturer's details. Not for FL11651 R3 AE FL11651 21 R3 26GulfRib 1x4 15- use in HVHZ Zones 32Plywood NonHVHZ-signed.p, Created by Independent Third Party:Yes 11651.22 26 Ga.Gul°Rib Min 26 Ga. GulfRib over 15/32" Plywood Limits of Use I Installation Instructions Approved for use in HVHZ: No fL11651 R3 II FL11651 22 R3 Metal Roof Panel Detail- Approved for use outside HVHZ: Yes signed.= Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 I Design Pressure: +N/A/-159.2PSF I Created by Independent Third Party: Yes Other: -69.25 psf© 24"o.c.fastener spacing. -159.25 psf @ Evaluation Reports '12"fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 22 R3 26GulfRib 15- use in HVHZ Zones 32Plywood NonHVHZ-signed,g Created by Independent Third Party: Yes 11651.23 26 Ga. GulfRib Min 26 Ga. GulfRib over 15/32" Plywood Limits of Use Isistallation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FL11651 23 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes jgned.Rdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-159.2PSFCreated by Independent Third Party: Yes Other: -71.75 psf©24"o.c. fastener spacing. -159.25 psf @ (Evaluation Reports 12"fastener spacing.Install per manLfacturer's details. For use I FL11651 R3 AE FL11651 23 R3 26GulfRib 15- in HVHZ Zones 1 32Plywood HVHZ-signed.= Created by Independent Third Party: Yes 11651.24 26 Ga. GulfRib Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 24 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Ybs jgned.pj Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party:Yes Other: -106.75 psf @ 24"o.c.fastener spacing.-164.25 psf @ Evaluation Reports 12"fastener spacing. Install per manu`acturer's details. For use FL11651 R3 AE FL11651 24 R3 26GulfRib 1x4 15- in HVHZ Zones 32Plywood HVHZ-signed,g Created by Independent Third Party: Yes 11651.25 29 Ga. GulfFJib Min 29 Ga. GulfRib over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 25 R3 Metal Roof Panel Detail- Approved for use outside HVHZ: Y@s signed,p f Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-123.5PSF Created by Independent Third Party: Yes Other: -76.75 psf @ 24"o.c.fastene spacing. -123.5 psf @ Evaluation Reports 24"fastener spacing. Install per mane cturer's details. Not for FL11651 R3 AE FL11651 25 R3 29GulfRib 1x4 15- use in HVHZ Zones https://www.floridabuilding.org/pr/pr_app_dd.aspx?param=wGEVX tDgsQFc5K%2fI'rZeCSHgw99R5wgrf90EegvlaBZ4cWkSTfwnA%3d%3d 2/3 14141111r;& „ FLORIDA PRODUCT APPROVAL GulfCoast PPLY & MANUFACTURING GULFaTh3 ' ivi 26 GUAGE GULFRIB PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.23 R3 Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga. GulfRibTM Roof Panel over 15/32" Plywood Florida Product Approval #11651.23 R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 . ''��‘ L S. , Newberry, FL 32669 : � E'' . kGti *: No. 75519 •. Engineer Evaluator: Dan Kuhn, P.E. #75519 :-fl. Florida Evaluation ANE ID: 10743 :1)%' STATE OF . cr: c OR ID Validator: ,',, ONAL EN�'``‘ Locke Bowden, P.E. #49704 ""' '� 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL#11651.23 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT J KUHN ENGINEERING, LLC 1200 CI INT MOORS RD. SUITE. 9. BOCA RATON. FL 33487 • H U:A ;O 4o-1 FLORIDA PRODUCT APPROVAL GulfCoast SUPPLY & MANUFACTURING GuLFRIBTM 26 GUAGE GULFRIBTM PANEL OVER 15/32" PLYWOOD FLORIDA PRODUC1 APPROVAL NO. 11651.23 R3 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. Product Description: GulfRibTN1 3/4" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.0ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/4" Major Rib at 9" O.C. Panel Fastener: #9-15 HWH 1.5" with sealing washing or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2017. Design Uplift Pressures: Table "A" Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" Design Pressure includes a Safety Factor= 2.0. FL#11651.23 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT KUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9. BOCA RATON, FL 33487 • FL COA #30464 V''4111111111111rh\ FLORIDA PRODUCT APPROVAL Gulf Coast SUPPLY & MANUFACTURING GULFRIBIVi ,_ 26 GUAGE GULFRIBTM PANEL OVER 15/32" PLYWOOD FLORIDA,,, , r ` .UDUCT APPROVAL NO. 11651.23 R3 Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • TAS 125-03 • UL 580-06 -Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. • TAS 100-95 - Test Procedure for Wind and Wind Driven Rain Resistance of Discontinuous Roof Systems • TAS 110-00 - Accel. Weathering ASTM G 155/Salt Spray ASTM B 117. Reference Data: 1. TAS 125-03: UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 1 17-0062T-07A-C Dated 02/19/2007 2. TAS 100-95 Farabaugh Engineering &Testing, Inc. (FBC Organization #TST-1654) Report No. T126-07, Dated 02/26/2007 Report No. T270-08, Dated 10/13/2008 3. TAS 110-00: Valspar Fluropon coated metal panel testing A)ASTM G 26 by PRI Asphalt Technologies dated 01/19/2004 B)ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004 4. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. 3. ASTM G 26 is equivalent to ASTM G 155. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. FL#11651.23 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT IKUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487 • FL COA #30464 .711411111111111r& FLORIDA PRODUCT APPROVAL Gulf Coast SUPPLY & MANUFACTURING GuLFRIpTM 26 GUAGE GULFRIB"' PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.23 R3 Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1515.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details and RAS 133. Underlayment: Shall comply with Florida Building Code 2017 section 1518.2, 1518.3, 1518.4 Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. FL#11651.23 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT I KUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487• FL COA #30464 ENGINEER'S LOAD TABLE SPEC Gulf Coast ( t� MANUFACTURING 41111) GuLFRIBTN, 26 GUAGE GULFRIB1M PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.23 R3 ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood Buildings having a Roof Mean Height 20'-0"; Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category II, fig? .frABuilding, bar,: ilfjorida Building Code 2Q 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. 1/4" (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZOF+4E`1 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 ZONE 3 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 12",TYPE 2 12",TYPE 2 12",TYPE 2 12",TYPE 2 1.)PANEL DESCRIPTION: GUL 1,1 MIN. 26 GA , ji,:ADE 80, 36"COVERAGE, 3/4" -; 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 71.75 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING: MIN. 15h2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE HIP ROOF a Note: Dimension(a)is defined as 10% of the minimum width of the building or ZONE 3 40%of the mean height of the roof,whichever is smaller,however, (a)cannot be +'._ _ a less than either 4% of the minimum width of the building or 3 feet. TYPE 1 FASTENER PATTERN RIDGE i 11 p At Panel La ZONE 1 Cont.Tape Seal for use on Slopes less than 3:12 ZI)#9-15 x 1-1/2"w/Sealer Washer at 24"O.C. EAVE ZONE 2 a GABLE ROOF TYPE 2 FASTENER PATTERN a 6.5" 2.5" 6.5" 2.5" 6.5" 2.5"' 6.5" 2.5"-e RIDGE Cont.Tape Seal for use on Slopes less than 3:12-1 4: (1)#9-15 x 1-1/2"w/Sealer Washer at 12"O.C. ZONE 1 ZONE3 EAVE FL# 11651.23 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT KUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487 • FL COA #30464