Loading...
1555 Selva Marina Dr ROOF19-0097 New Metal over Existing ROOF NON SHINGLE PERMIT PERMIT NUMBER ROOF19-0097 •;;p CITY OF ATLANTIC BEACH ISSUED: 12/26/2019 800 SEMINOLE ROAD kr.);ilv�~ ATLANTIC BEACH. FL 32233 EXPIRES: 6/23/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1555 SELVA MARINA DR ROOF NON SHINGLE new metal roof over existing $10000.00 roof TYPE OF REAL ESTATEZONING: I BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 171946 0000 SELVA MARINA UNIT 02 COMPANY: ADDRESS: CITY: STATE: ZIP: OWNER: ADDRESS: CITY: STATE: ZIP: ARTHUR RICHARD WORSHAM 1555 Selva Marina Dr Atlantic Beach FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Appi Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $161.86 Issued Date: 12/26/2019 lof 2 0i:V4J, City of Atlantic Beach APPLICATION NUMBER ri4. ;rJ `.;��a Building Department (To be assigned by the Building Department.) r d �, 800 Seminole Road D �o F C:� -p o j., s Atlantic Beach, Florida 32233-5445 �--l.i 6 � � Phone(904)247-5826 c Fax(904)247-5845 f 3-3 �� �r E-mail: building-dept@coab.us Date routed: 6 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l C�� `J-""`el CLII IOf, : - •r. - 't review required Yes No Building t: Applicant: D "i l(‘-0--( - anning &Zoning Tree Administrator Project: t'n� , 101) -- NH 12-V, #.6, Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date A of Permit Verified By (�f ,:). Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: (proved. ❑Denied. ❑Not applicable (Circle one.) Comments: /DOC_ �II Iw h o►ry•-row+n 42 r l �ov,1 t�t,►� BUILDING i_. .3 �� PA 1 120a Qetvi r-es .1.-. P ross PLANNING &ZONING /�s e t // S. Reviewed by: Date:/L'.6"aCi9 TREE ADMIN. Second Review: Approved as revised. ['Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 BuildingPermit Application OFFICE COPY Updated 10/9/18 ' ,•. p p �,..-i ; City of Atlantic Beach Building Department **ALL INFORMATION �' j 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY rr�, ,arIS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 155 .5 C"iv, to a(,.,,i Or ," Permit Number: Q C1OF(el— d 0` 1- Legal Description44.. . . ,-j, �, JI)ValuationofWork(ReplacementCost)$ i OOHeated/CooledSF , t O Non Reated/Cooed • - • Class of Work: l New ❑Addition ❑Alteration *Repair DMove ODemo DPool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial *Residential DEC 2 3 2019 • • If an existing structure,is a fire sprinkler system installed?: ❑Yes *No • Will tree(s)be removed in association with proposed project?DYes must submit se.arate ea.'el ova Perm't Describe in detail the type of work to be performed: ;',i,yi ai ,,,,,,,e ,n eh,I E's d: r 1 s I, 1,6 Florida Product Approval# 1 i 6 5 / . d.0 R 3 All-4th( for multiple products use product approval form Property Owner Information/ ( ,� / 1 Name f\. : � 1- .1rei ft r �'1.�(r Address I --Cell/i4 %NAL, (!ft• City A 7'f -,d,s tj ,f,,,,f I; I f=t� State cl Zip j j c?' L f k}L Phone d - 7/i'] 4 E-Mail J' r .1.,�, ,' L. ltf t/a t,u L1 + t^^ r( c-) ! loa 4i, Owner or Agent(If Agent, Power of Attorney or Agency Lett Required) Contractor Information I(� /� ,�( /1 LIJ Name of Company E" •,'Enai rA ,t r' ��•�_ ()U�"`Qualifying Agent A,j tit4,(( l f 11-jk- - V N Vt Address City State Zip • _ ..I Z Office Phone Job Site Contact Number M 0 _`t O iNi State Certification/Registration# E-Mail .LLr, IM O 0 id Architect Name&Phone# 0 m A Z !- Engineer's Name&Phone# 0 0 -1 8 8 Workers Compensation Insurer OR Exempt oK Expiration Date Iii I— C3 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or instal l() ® a commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regfat cnu- H construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, N b Z WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE:In addition to the requireme s Cf.tl s permit,there may be additional restrictions applicable to this property that may be found in the public records of this coudy,Q•1 m there may be additional permits required from other governmental entities such as water management districts,state ag i ;� 5 0 federal agencies. LU p W Li VNw• OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance wfiln all CC LU applicable laws regulating construction and zoning. LA > C". CC WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. /1—' (Signature o Owner or Agent) (Signature of Contractor) Signed and sworn to(or affirmed)before me this a5 day of Signed and sworn to(or affirmed)before me this a; day of n Jew \yc 49.01 a , by / PM 1.04 Thtk. r Dectimilar , tlot& , by 0 Mt Mil'lr0.JMo(1 (Sign atL‘. VI -1Q,9Sy, �O ''% a—,�ignature of ' IQ /���,� =2QQ- , OTARY ,r TARr�Sy ` [ ]Personally Known OR -'C.I My Comm.Expires 70 [ ]Personally Known OR ?U My Comm.Expires 73 [ ] Produced Identification ti. July 15.2023 s [ ]Produced Identification _ July 15,2023 t Type of Identification: s Comm.#GG 354709 _ Comm.#GG 354709 - yp OL Type of Identification: II L a '�,TF OF !1.09�`�� 9rF OF F1�Q.0°\� Owner Builder Affidavit **ALL INFORMATION HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. i /l 800 Seminole Rd, Atlantic Beach, FL 32233 '`"`=`--'r Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#:goOT19-6199d I. FLORIDA STATUTES;CHAPTER 489, FLORIDA STATUTES, PART 1"CONSTRUCTION CONTRACTING" REQUIRES OWNER/ BUILDER TO ACKNOWLEDGE THE LAW: IDISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE,WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY;SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. . III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES.OWNERS BEING SUBJECT TO$5,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY"CERTIFICATE OF COMPETENCY" OR THE FLORIDA"CONTRACTORS CERTIFICATE"TO ASCERTAIN IF A PERSON ISA LICENSED CONTRACTOR. CONTACT THE BUILDING DEPARTMENT(904- 247-5826 OR BUILDING-DEPT@COAB.US ) IF IN DOUBT. V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANg OF AN OWNER-BUILDER PERMIT. Job Address: 151 cft Arm '1,/(0Q Owner Name: _ ^'( J/yn✓ I A ;tez /� J Phone Number: f L LILO,/ / f 6'( Mailing Address: t S IL- NIS ty: /'1'' r� [�R ,�t State: /`'L Zip: 312- " Notarized Signature of Owner The fAegoingg instrument was acknowl dge efore me this a3 day of Vocember, 201 Ck, in the State of Florida, County of \J1„l/04A ����•� �pN THA),"'%,, Signature of Notary Public OTpRy �y= [ ] Personally Known OR [ ] Produced Identification Q My Comm.Expires 1 July 15,2023 Type of Identification: $01— s Comm.*GG 354709 %`S'� PUBoC' OPS° Updated 10/24/18 OFFICE COPY Scope of work for New Roof at 1555 Selva Marina Drive. Existing Roof composed of Plywood Base, Peel and Stick underlayment, followed by Modified bitumen Roof approx. 15/ 20 years old. New Under laminate, followed by Bubble Foil, then 1 x 4 Purlins, then 26 Gauge Metal Roof. All material data sheets and approvals enclosed. Installed per Florida Build Code. Any Questions Owner—Richard Arthur 904 422 7424 OFFICE COPY , Z-4141Lwa\ , Coast ,,„ - , FLORIDA PRODUCT APPROVAL Gulf SUPPLY & MANUFACTURING As) GULF w. 26 GUAGE GULFPBRT"PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.20 R3 Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga, GuIfPBRTM Roof Panel over 1x4 Wood Purlins over 15132" Plywood Florida Product Approval #11651.20 R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 soolisfes, E Engineer Evaluator: �,G NiNSF '4'�: � r Dan Kuhn, P.E. #75519 :* No. 75519 Florida Evaluation ANE ID: 10743 � 1 T . STATE rArE of ;Q , Validator: .."A\,... As, r' .(",,,. < ORIO •'� .SLocke Bowden, PE. #49704 '•S;?NAL • G` `9450 Alysbury Place % o` t 05 202 Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL# 1 1651.20 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT ` JKUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9,BOCA RATON, FL 33487 • FL COA#30464 • . V:X. , FLORIDA PRODUCT APPROVAL Gulf .a ,_ SUPPLY & M. 26 GUAGE GULFPBRTM PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.20 R3 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1504.7. Product Description: GulfPBRTM 3/4" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over Minimum 1x4 Wood Purlins over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.0ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 11/4" Tall Rib at 12" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing, 1/4-14 x 7/8" HWH with sealing washer at 24" O.C. Maximum at the panel side laps or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 1x4 No. 2 SYP wood purlins over min. 15/32" thick, APA Rated plywood over supports at maximum 24" Q.C. The 1x4 wood purlins shall be fastened to the plywood with minimum 8D x 21/2" Ring Shank Nails at 4" O.C. Design of 1x4 wood purlins, plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2017. Design Uplift Pressures: Table"A" Fastener Pattern 12"-12"-12" 7"-5"-7"-5"-7" Design Pressure includes a Safety Factor=2.0. FL# 11651.20 R3•OCTOBER 5,2017 ii. PRODUCT EVALUATION REPORT IKUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487• FL COA #30464 / V FLORIDA PRODUCT APPROVAL Gulf Coast „. SUPPLY & MANUFACTURING IL ;a 26 GUAGE GULFPBR'" PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651,20 R3 Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 -Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. • FM 4471-1992, Section 4.4 Foot Traffic Resistance Test Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0062T-07, Dated 02/19/2007 2. FM 4471-95, Section 4.4 Foot Traffic Resistance Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0238T-09, Dated 07/21/2009 3. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519)@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. 3. The FM 4471-95 test standard is equivalent to the FM 4471-1992 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. FL#11651.20 R3•OCTOBER 5,2017 r. PRODUCT EVALUATION REPORT ::,,, JKUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487 • FL COA #30464 • • .,114111Pro\ ., Coast 3 ` FLORIDA PRODUCT APPROVAL Gulf SUPPLY & MANUFACTURING ...16 IL 26 GUAGE GULFPBRTM PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD ,„ : FLORIDA PRODUCT APPROVAL NO. 11651.20 R3 Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.20 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT IKUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487• FL COA #30464 • /ix. ENGINEER'S LOAD TABLE SPEC Gulf SUPPLY & MANUFACTURING F p TM t 26 GUAGE GULFPBRTM PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.20 R3 ENGINEER LOAD TABLE: 26 Ga. GuIfPBRTM Panel over 1x4 Wood Purlins over 15/32" Plywood u lr Ings Pav:rig a Roof Mea: Night= 20'-0", Roof Slope: 2'712" - 12"/12" Gable or Hip Roof; Wind Speeds 120- C., Flis< Cawg , Enclosed Build ng, based on Florida Building Code 2017. 120 130 140 150 160 170 180 WIIND FASTENER SPEED (MIN. SUBSTRATE ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING i x4 W i ZONE 1 #9-15x1.5" Purlinsoad 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 ZONE 2 #9-15x1.5" 1xPuli4 Wnsood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 1x4 Wood ZONE 3 #9-15x1.5" 24 TYPE 1 24",TYPE 1 24 TYPE 1 _24",TYPE 1 24",TYPE 1 12",TYPE 2 12",TYPE 2 1.)PANEL DESCRIPTION: GULFPBRTM, MIN. 26 GA., ..,RADE 80, 3o"COVERAGE, 13/4" TALL. 2.)PANEL FASTENER:#9-15X1.5"W/SEALING WASHER OR APPROVED EQ., '/4-14x'/s" HWH LAP SCREW AT 24"O.C. IN PANEL SIDELAP. 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:94.25 PSF @ 24" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, 151.75 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)SUBSTRATE: 1X4 WOOD PURLINS OVER MIN. 15/32" THICK PLYWOOD.WOOD PURLINS ATTACHED TO PLYWOOD W/MIN. 8D X 21/2" RING SHANK NAILS AT 4" O.C. PURLINS AND PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or -ZONE 2 ZONE 3 ' 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be 1_ a less than either 4%of the minimum width of the building or 3 feet. TYPE 1 FASTENER PATTERN RIDGE —1 x 4 Wood Purlins @ 24"O.C.Attached to Plywood with r ,/ (1)8d x 2.5"Ring Shank Nails @ 4"O.C. #14 x 7/8"Lap Screw @ 24"0.C.Max.- ZONE 1 I I (i)#9-15 x 1-1/2" \--Min.15/32"Plywood At Panel Lap-21 EAVE 12"-12"-12"Fastener Pattern @ 24"O.C. ZONE 2 GABLE ROOF ;a TYPE 2 FASTENER PATTERN —RIDGE •I--1 x 4 Wood Purlins @ 12"O.C.Attached to Plywood with (1)8d x 2.5"Ring Shank Nails @ 4"0.C. a 1� #14 x 7/8"Lap Screw @ 24"0.C.Max. . _ La .Ie-- " ' 7., n " a 70 5n ZONE "-1 — • -(1)#9-15 x1-1/2" Min.15/32"Plywood ZONE 3 EAVE 7"-5"-7"-5"-7°Fastener Pattern @ 12"O.C. FL#11651.20 R3•OCTOBER 5,2017 PRODUCT EVALUATION REPORT KUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON. FL 33487• FL COA#30464 NOTICE OF COMMENCEMENT State of Florida Tax Folio No. 171946-0000 County ofDuval .( To Whom It May Concern: °G g(" -tI �0��19 —°0y S - 17 - 3b0 The undersigned hereby informs you that improvements will be made to certain real pro rty-, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 27-6 16-2S-29E SELVA MARINA UNIT 2 LOT 12 BLK 3 Address of property being improved: 1555 Selva Marina Drive,Atlantic Beach,FI,32233 _ General description of improvements: New Metal Roof to be installed over existing Modified Bitumen Roof. Owner: Richard Arthur Address: 1555 Selva Marina Drive,Atlantic Beach,FI,32233 Owner's interest in site of the improvement: Home Owner Fee Simple Titleholder(if other than owner): Name: Richard Arthur Contractor: Richard Arthur Address: 1555 Selva Marina Drive, Atlantic Beach, FI, 32233 Telephone No.: (904)422-7424 Fax No: Surety(if any) Address: Amount of Bond$ _ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Not applicable Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: l CL-1 Ar*h GC Date: I/L/at d-0 1 Before me this day of a County of Duval,State Doc fe?nonnno414 OR BK 10057 Page 2317, Of Florida,has personally appear f ' ct�� Number Pages: 1 Notary Public at Large,State of Florida,County of Duval. Recorded 01/06/2020 02:16 PM, My commission expires: RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL Personally Known: D. BENE ANGERS or COUNTY )MY COMMISSION uGG228701 RECORDING $10.00 Produced Identification: y 28 2022 r tXF'IKrJ cul