Loading...
95 W. 2nd St ACRS20-0008 HVAC permit OFFICE COQ Y Revision Request/Correction to Comments **ALL INFORMATION f' HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: 4C2O1J) 3 IlfRevision to Issued Permit OR ❑ Corrections to Comments Date: /42 -2 a Project Address: 94- ✓V Q 1/1 d .3L /7 Bead/ FL ? ) .zS Contractor/Contact Name: va/011 1- oc6 h chO' Contact Phone: yn4) ,24C- 1318 Email: avalOV1 pekkn1-S x/22/J, can Description of Proposed Revision/Corrections:Ekoe thei/ iifekl p)czi4 J/ t1 bW Wl ff -1a ea/eu/ zlrDw,� I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Will proposed revision/corrections add additional square footage to original submittal? JAN 2 2020 iNo ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? - _ F No ❑*Yes (additional increase in building value:$ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) 14proved H Denied r Not Applicable to Department Permit Fee Du S v��11 0 Revision/Plan Review Comments Con I o 4 U�?/c-(1) h CO ix 2e v%_Voek �DG e AfS e fay Pee-. Department Review Required: Building "111) ' Planning&Zoning Reviewed By Tree Administrator Public Works Public Utilities f 9- 3-6 Public Safety Date Fire Services Updated 10/17/18 REVISION 4 Duct System Summaryjob: wrightsOft' Y 8P# /9C/-5��-- --...Date: Dec 20,2018 Entire House or/j9 o BY Avalon Heating and Air StratED 3665 Spring Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:wwwavalonac.com License:CMC1249968 Project Information For: American Classic Homes 95 W 2nd St,Jacksonville,FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.12 in H2O 0.12 in H2O Available static pressure 0.38 in H2O 0.38 in H2O Supply/return available pressure 0.294/0.086 in H2O 0.294/0.086 in H2O Lowest friction rate 0.247 in/100ft 0.247 in/100ft Actual air flow 1300 cfrn 1300 dm Total effective length(TEL) 154 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (dm) (cfm) FR (in) (in) Mab Ln(ft) Ln(ft) Trunk Bath 2 h 689 33 26 0.280 4.0 Ox 0 VI Fx 14.9 90.0 st1 Bedroom2 h 2175 105 97 0.270 6.0 Oxo VIFx 18.8 90.0 st1 Bedroom3 h 2079 101 99 0.265 6.0 Oxo VIFx 20.9 90.0 st1 Bedroom4 c 1618 70 83 0.272 7.0 Oxo VIFx 18.1 90.0 st1 Dining h 3518 170 111 0.290 6.0 Oxo VIFx 11.4 90.0 st2 Entry/Stairs h 3731 180 77 0.260 6.0 Ox 0 VI Fx 22.9 90.0 st2 Family h 2622 127 118 0.264 7.0 Oxo VIFx 21.3 90.0 st2 Family-A h 2622 127 118 0.260 7.0 Oxo VIFx 22.9 90.0 st2 Kitchen c 2393 69 123 0.281 7.0 Ox 0 VI Fx 14.6 90.0 st2 Laundry c 1180 25 60 0.399 4.0 Oxo VIFx 3.6 70.0 Master Bath h 307 15 14 0.285 4.0 Ox 0 VIFx 13.0 90.0 st1 Master Bath-A h 265 15 14 0 0 Ox 0 VI Fx 0 0 Master aoset h 396 19 16 0.280 4.0 Oxo VI Fx 15.0 90.0 st1 Master-A c 4413 113 226 0.271 8.0 Oxo VIFx 18.2 90.0 st1 Powder h 780 38 12 0.247 4.0 Oxo VIFx 28.9 90.0 st2 Stairs/Hallway c 2086 94 107 0.264 4.0 Oxo VIFx 21.3 90.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (dm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 711 558 0247 905 12.0 0 x 0 VinIFIx st1 PeakAVF 550 668 0.264 478 16.0 0 x 0 VinIFIx w r ightsoft. 2020-Jan-03 15:49:19 .` ,,,,,,,,.,„„,�,,,,,,,,,_,.9,,,., Right-Suite®Universal 2019 19.0.04 RSU23882 Page 1 ...Wome\DropboxtDuct Layouts1.95 W 2nd St 1967.rup Calc=MJ8 Front Door faces:NE OFFICE COPY Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfrn) (cirri) (ft) FR (fpm) (in) (in) Opening(in) MatI Trunk rb1 Oxo 1300 1300 35.0 0.247 931 16.0 Ox 0 VIFx w r ightsof t" 2020-Jan-0315:49:19 � Right-Suite®Universal 2019 19.0.04 RSU23882 Page 2 AiM ...Wome\Dropbox\Duct Layouts\95 W 2nd St 1967.rup Calc=MJ8 Front Door faces:NE N Level 1 Ul-HL;t (U Y °r. A ��i rimmimilim il 1 « 127 cfrn Dining 170 cfm _„: * et 6" Family f , LI 40 3 a A127 cfrn 12" 7" WI tchen P24 i.It 123 cfrn i n Via , -. > „ ,e- Powder . 180 «., Y' • it N ri e Entry/Stairs i Garage 3r fi. I r. Vii. NI DI I Pi 6'r'':I::: , Pi '...§i Job#: Avalon Heating andAir Scale: 1 :58 Performed for: Page 1 American CIasecHorres 3666 Sang Park Rd RghtSuile®UnKesa12019 95 W 2nd St Jackscrulle,FL322J7 19.0.04 RSU23882 Jad®nulle,FL 32233 Ft ur 9)12451818 2020.13n-0315:4928 war �� ...uctLa�oue�95W2nd St1967iup N 4 ' OFFICE COPY \ Level 2 ri /faster aoset ril E; Bedroom 2 ;, Master ►1IN 226 cfm ' klilkol ..4i '" fm 05 cfm !- = 14x6 Ii 4„ ow. '60 cfm - ► , Laundry - " � 1 fm 301. r Master Bath W f 4 15 cfm 4„ l Rt.1 Bath 2 33 cfrn ' 6" 7 airs/Hallway 107da :i: