Loading...
113 Seminole Rd ROOF20-0001 Mod Bit Torch g1AV-7- ROOF NON SHINGLE PERMIT PERMIT NUMBER gism.s`'`` ROOF20-0001 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ISSUED: 1/14/2020 tilt �rATLANTIC BEACH. FL 32233 EXPIRES: 7/12/2020 MUST CALL INSPECTION PHONE LINE(904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS; PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 113 SEMINOLE RD ROOF NON SHINGLE MODIFIED BITUMEN TORCH $8000.00 DOWN ROOF TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: I 170612 0100 SALTAIR SEC 01 COMPANY: ADDRESS: CITY: € STATE: ; ZIP: JOHN GILMORE ROOFING, 11650 MONTEZ LANE JACKSONVILLE FL 32223 INC. OWNER: ADDRESS: CITY: STATE: ZIP: WHITTINGSLOW JOHN D 325 17TH ST ATLANTIC BEACH FL 32233-5822 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $95.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $47.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.14 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $146.64 Issued Date: 1/14/2020 1 of 2 sciROOF NON SHINGLE PERMITPERMIT NUMBER CITY OF ATLANTIC BEACHROOF20-0001 V800 SEMINOLE ROAD ISSUED: 1/14/202001.4 _____.,,,,,,,,,,,, _ �a ATLANTIC BEACH. FL 32233 EXPIRES: 7/12/2020 Issued Date: 1/14/2020 2 of 2 r•S y\,ir;, City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) r� 'i' 800 Seminole Road 1RooF ZO-OOG1j ,r �' AtlanticBeach, Florida 32233-5445 1 Phone(904)247-5826 • Fax(904)247-5845 C� 7 �*� ..01110. y E-mail: building-dept@coab.us Date routed: I /9 /Z 0 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 11 3 S G YI I OLE Department review required Ye No p y uildin f Applicant: JOkN el, ( (r(YlOQt ROPi/OC PlanningYZoning ree Administrator Project: _O IQ (y Aoo it ( ►vPublic Works G Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department I First Review: proved. ❑Denied. Not applicable (Circle one.) Comments: BUILDIN PLANNING &ZONING Reviewed by: / Date: /"'/0-(96 TREE ADMIN. Second Review: ❑Approved as revised. Denie . ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. I Denied. Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 i' �'� Building Permit Application Updated10/9/18 -v Ale, OFFICE COPY W$ City of Atlantic Beach Building Department **ALL INFORMATION +.— 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY 't�' IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: //3 Sem 4 1 o It I /Q l otAi ht.- omeli Permit Number: d(--)F- Z O O ao i Legal Description /0 g jD-LS -L9e 54/f *-rf Sec / 14f-637RE# Valuation of Work(Replacement Cost)$ Ow, 'O Heated/Cooled SF ii-ei 0 Non-Heated/Cooled • Class of Work: ❑New ❑Addition ❑Alteration VRepair ❑Move ❑Demo ❑Pool ❑Window/Door W O • Use of existing/proposed structure(s): ❑Commercial Residential U N. Z N lit • If an existing structure,is a fire sprinkler system installed?: ❑Yes eNo Q .J Z Q 0 k • Will tree(s)be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) 1'. 2 t`= u Describe in detail the type of work to be performed: �dc <frQ �f � Q �d�v 'Wm d tilj RC/4ov �yy �/cil R I:? -fid AI 4i',1 4 ,t/ &ni ,i s`t n o 0 / •� p u Florida Product Approval# r .4. 7330./ [ /'y77 / for multiple products use product apprdal Erg ZZ Property Owner Information r / () u- N Name /tk (r(J4,f�.tf,1f&i Address ;2-Sr l '1 1\ STd En Z City 1/11V444 h(., 4eir[, ' State �_i— Zip 3z L-"; 3 Phone la (f 710 .5-0� Y O u.. n- E-Mail ,rdii.(it 4fc / ' 3 8 6 uL f t o—, Q 0 UJ W 5: Owner or Agent(If gent, Power of Attorney or Agency Letter Required) " - m W >"' Contractor Information Lu p w -� t;j0cnu Name of Company-,Id/j,L/ a,-4,40"- ? .:. 4,0_.. Qualifying Agent �14v C,"/MQ/l 5. CC W Add ress4.cp-40 ftv C �h.L City, y t' // State Al/ Zip a..1.2-2ew Office Phone 1 -q014. V 8D -- 1.0.€7/,‘ Job Site Contact Number /-50i4- L',5'5-i S''$'7 State Certification/Registration# Ceea 5-74 71 E-Mail J 4`,-Ji1 6,1 E 1`'tleb1L1N,9 9ACV,i.ee.4.4 Architect Name& Phone# /I/i1 Engineer's Name&Phone# Workers Compensation Insurer Je5/ .S-LF OR Exempt❑ Expiration Date /`,2i a / Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition the eqments of this permit,there may be additional restrictions applicable to this property that may be found in the public r ds�f t;i1�ui es co'Pr+tyg a id;' �i.._, there may be additional permits required from other governmental entities such as water management dist ch7ttea (kAn— �--•LL.----r-1- federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will ble done in compli � witlinall2020 applicable laws regulating construction and zoning. 1 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERpY l G!�ni IWI Ff 11fi ent TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEYI eF�` FSE -T1':f beach, 7 f_. RECORNG Y.0 Ili OTICE OF COMMENCEMENT. kt-- LAI fr;? (Signat ,: of Owner or Agent) (Sig �nature of Contractor) L/YFeZ---- Signed and sworn to(or affirmed)before me this day of Signed and sworn to(or aff'rmed)before me this( f ' day of ianwury , .0..1.1^, , b 0 n (Jho! ik i• w S.' . . 2.03 , by • . Et' t WO re, ,,,,,,,,, ,,, `°�6;,,, VIRGINIA ROSALES 6C'gnature o Notary) ,oiPa"PUe VIRGINIA ROSALES �; ature of otary) '�" •`1 NotaryPublic-State of Florida 1 P.:1—W%i. Notary Public-State 01 Florida •* Al +,_ F.•. iii' • Commission #GG 059564 "sa„ 'r i • Commission #GG 059564 '''',1,17c7117,701,-;',' [0,WIMPNiff-�3`^JPr(ct,2021 , 0in TelW0d1lfr�1419iN95an 27,2021 0 4 Pr•. -. •-i . '111r uced Identification Y Type o identi 'cation: ' v' Type o !dent 'cation: Pier c1-- 4"aoF' an , 691 NOTICE OF COMMENCEMENT OFFICE COPY State of Tax Folio No. County of OW'4 ( To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated inOthiis NOTICE OF MENCEMENT//. Legal Description of property being improved: !/ 3 $eu. i kwie.. f f'�^t fit I@t1G it rt: 3 Z 3 3 ld�ge 54-11-the sets I L.421- 637 r ,/ /r Address of property being improved: // Sem /4 04- eo e( t 1�a t"t C �7�A.( ' PL 3 Z-2 General description of improvements: /?L= 11Q/14i Owner: t f O&t`1 (17-1't )( ) Address: 3 Z--5- I//'7 >' °�`� 1.1^1 ftc, 6 &iG6� f Co. 3 2Z) - s Owner's interest in site of the improvement: s/Ur (•ettrC tw #19 Fee Simple Titleholder(if other than owner): Name:Aup / `\1 Contractor: a IiAl a;7/Aft 13A4 Rc Fe/li 'yC /Iu1 Address: 4 r . i ._ % r :,?C,• / - — Telephone No./-j 120 -'2Q'< U d J �� Fax No: y Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Doc#2020002256,OR BK 19057 Page 1777, Number Pages: 1 Name and address of any person making a loan for the construction of the improvements Recorded 01/06/2020 12:32 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL Name: COUNTY RECORDING $10.00 Address: Phone No: Fax No: Name of person within the State of Florida, other than himself,designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: / n'/ Date: t A(� --‘,0 ,,,�� „ Before me lis , �, day of 'her >11Q-0in the County o Duval,State • oar`�a( VIRGINIA ROSALES Of Florida,has personally appeared ...40140 Gent CO FRIT/NS(,0t.4 . Notary Public-State of Florida Notary Public at Large,State of Florida,County of Duval. Commission tx GG 059564 f l?- 067-1 �." ii ` , My commission expires: l y7 "4;Rug;,,, My Comm. Expires Jan 27,2021 Personally Known: i or •mw• Produced Identification: � 0� OFFICE COPY • Leather work shoes with synthetic:or:smooth leather soles. *Leather work gloves That adequately shield the wrist area.Refer also to the"Safety"section on page 53for information regarding proper work attire. Roof Layout As with most types of roof installations,afttfastic modifl-ij j installation begins at the low point of the roof with successive rolls installedso that no laps are against the flow of water.When membrane - is applied with hot asphalt,where roof slope is 1"per foot or less,,sidelaps are installed perpendicular to the direction of the roof slope. In,situations where the roof slope exceeds 1"per foot, rolls are installed wLth the sidelaps running-parallel to the slope directions.APP modified membranes can be installed with sidelaps perpendicular to the slope where roof slope is 2"per foot or less(over 2"Install sidelaps parallel to roof slope direction). Additionally,where roof slope exceeds 1"per foot for SBS modified and self-adhering membranes or 2" per foot for APP modified "Pack-nailing" of membrane is required.Refer to the General flecommenda>tions section of the CertainTeed Commercial ercial.Roof Systems Manualforback-nailing guidelines. Endlaps are to be staggered. In multi-ply applications, membrane sidelaps must also be staggered. • F�. • • • Endtap *? • 2'Sidelap ----'I # --- Endlaps Staggered Min.3'Apart 26,14 4 --- 393I8" 4 191t1/16' Base Flintlastic Flintlastic Meddled Sheet Interply Sheet Bitumen Cap Sheet In multi-ply systems,stagger sidelaps from interply and base sheet sidelaps 17 -�? a+-.d'.Endlnp • f 2" Stdelap -- -- • ft . 1 39'3!& 19 Ii&" e*„. Base Ftintlastic Modified Sheet Bitumen Gap'Steet Stagger field sidelaps from base sheet sidelaps Warning: Flintiastic Modified Bitumen application may require the use'of hot asphalt and/or an open flame roofing torch.Improper application practices may cause physical injury to the applicator or damage to the property. Refer to the current CertainTeed Commercial Roof Systems Manual for further information Basic Application: F in't;as i ' APP Modified Eiturriena Prepare the substrate as described on.page/O..FtWitlastic APP modified bitumens must be applied using a professional roofer's torch. Use of hand-held roofing torches is recommended and affords the most control If multiple burner torching machines are utilized care must be taken to assure uniform heat application and to avoid overheating of the membrane. Begin membrane application by unrolling the roll and aligning the sidelaps. Rte=rsoll the rail halfway. !-, Standing on-the unrolled portion to G` prevent shifting, begin torching the Y }' exposed polyethylene side of the rs; rolled portion.Walk forward as you torch, pushing the heated coil s� tS:mAuar_ forward and into place with your boot. 2.1J ,. Position and align the roll 18 Proper torching procedure Involves passing the torch flame in an "L"pattern across the coiled portion of the roll and up the sidelap area. As subsequent rolls are installed, heat is applied both to the roll and the exposed laps of the membrane being overlapped onto.As it is heated,the roll becomes shiny and the polyethylene film melts away.Adequate heat is confirmed when a uniform flow of melted bitumen compound flows evenly in a 1/4"-1/2" uniform bead that oozes from the applied membrane's edges. Be sure to heat the entire roll evenly, not just the lap areas,with extra concentration at the laps. Once at the end of the roll, re-roll the untorched half, pulling back to beyond the starting point as much as possible, and repeat the torching procedure_ j YS �4 c.S1-5�0 ..„ ,7,,.:43/45':• " .4 ININI,,i..544,- T �. .r r J-. 3" Sidelap -;%::'` .. µ Uniform Bitumen 1 f. 1 tl Proper torching,in an"L"pattern,assures uniform 1/4'-1/2'compound and flow at laps and adequate heat across the coil Trim the lower outside corner of the roll at an angle as shown. Overlap subsequent rolls 3"at sidelaps (or as specified, min. 3") and 6"at endlaps. Sidelap lines are generally indicated for the applicators' convenience. 19 r '.., 214Z 4S!„).. • f F :L.f`• ?a .i� .1",.0-4., 44' rG cY r }yy • 1 XLH aN' vi se �'� j r 4t `\ '' -. -a-0�i. ms's ,,E-. t Sidelap \\\� Overlap Flintlastic STA sidelaps a minimum of 3" Trim the upper outside corner of the subsequent rolls as shown.All trimmed corners will be covered with the subsequent rolls. r c�S y `Gt;?f - S� yJ i i tri mor/� cr.4Low, S' Endlap cuts are made at an angle as shown 20 It Is critical (especially at the lap areas)to apply adequate heat to both the membrane being instated and the area of membrane being overlapped onto. Granuled APP membranes require treatment of the underlying lap granules by heating and removal or heating and pressing to insure a proper end lap weld.A warm trowel should be used to check laps for an adequate seal.Any unbonded areas must be lifted and retorched. Do not attempt to reseal by torching the top surface of the membrane. Flashing Details: Flintlastic APP rvioditied Bitumen Flashing details are accomplished using cut pieces of Flintlastic APP modified bitumen in combination with appropriate prefabricated flashing components.The same sidelap and endlap rules apply to flashing details as to field membrane. Examples of typical flashing details are as follows: %Liam, - sve Parapet Wall i& Noncombustible cant strip must - be installed at the base of the —, parapet wall. Field membrane plies must extend a minimum of `: 2" beyond the top of the cant strip. ' For nailable walls, appropriate base sheet must also cover parapet wall and extend to the top of cant strip. Base sheet extends over the top of parapet and is mechanically fastened. Parapet wall flashing membrane Concrete wall with metal counterflashing (Flintlastic APP modified bitumen) not exceeding roll width must — I extend to the outside edge of the parapet wall if coping is used, ' or a minimum of 8"above the top of the cant strip if termination bar and counterflashing are installed, ++ Parapet and a minimum of 4"onto the completed field membrane. < Wood parapet wall with metal coping 21 Parapet Inside Corners Base of corner: Make a"V"-shaped cut in the Flintlastic APP modified bitumen membrane to permit it to conform to the inside corner fold (both sides of the "V" will neatly overlap when folded into the corner). Use a trowel to press the heated membrane flaps into place. Top of corner: Cut a notch part way to permit the top of the membrane to conform to the inside corner and fold over the top of the parapet. Cap the resulting gap with a strip of Flintlastic APP modified bitumen. Fhntfastre Smooth 17 Wide Strip --., Base Sheet .•. 1 ' •t 4 9V f ^5 ;1 K f i r €'*, e ,rsly-. ct Cant Slrio— -•," Inside corner(parapet)detail-,torch applications-part A V-Cut in Membrane to Accommodate Fold `� First Flinttastic Smooth f Gounlertlash Strap } Inside Domer(parapet)detail,torch applications-pert B 22 Second Flintlastm-Smooth Countedlash Strip Notch Cut in Counterllashing to Accommodate Fold t r y t , Inside corner(parapet)detail,torch applications-part C Metal Coping ? I Flintrastic Membrane Cotner Pieces Inside corner(parapet)detail,torch applications-part D 23 Outside Corners and Curbs At outside corners such as curbs, the reverse situation occurs from that of inside corners.The "V"-shaped cut goes at the top of the • membrane strip and the notch or straight slice at the bottom, " ; ;.d.,:, since the membrane is folding the opposite way. In this case, cap the opening at (7, °o o the bottom of the strip which k�extends onto the field of the Outside corner(or curb)detail, roof a minimum of 4" mineral surfaced torch applications-pert A Note:Completed field membrane shall be extended st F+aac, rA;mr�7 2"above top edge of cant Zsitonterli.o.r.S�:; and solid attached to cant strip only. Outside corner(or curb)detail, mineral surfaced torch applications-part B • dYL.h Ji`f S ,,,•'t _-. Crarmi^ath Stry Outside corner(or curb)detail, mineral surfaced torch applications-part C nn Metal Edge Detail -Mineral Surfaced Applications Base sheet must extend over fascia a min. of 2".A min. 9"wide strip of flashing membrane (Flintlastic APP modified bitumen)should then be applied to the base sheet, flush with the roof edge and extending 9"onto the field of the roof. Appropriate edge metal (min.26 gauge, primed) must be properly installed and secured (in two rows, „4'1 spaced every 6"staggered, fasteners placed every 3"). ' Finally the mineral surfaced V°rl`1iec / f "� : " � t R'turren • Flintlastic APP modified Interpw -' :. bitumen cap sheet is in- • l a „ u stalled securely over the 4" Ce+tanTe d 'tg' edge metal face (continuous BaPe S+,eat from the field of the roof). Metal edge details,Flintlastic GTA granule surfaced APP Modified Bitumen Membrane Metal Edge Detail -Smooth Surfaced Applications Base sheet must extend over fascia a min. of 2'. Next, the smooth surfaced Flintlastic APP modified bitumen field membrane is installed, cut flush with the roof edge.Appropriate edge metal(min. 26 gauge, primed) must be properly ;=v,�� 045 Installed and secured. '" • A min. 10"wide strip of x Flintlastic APP modified bitumen smooth surfaced membrane should then be applied over the metal • (flush to the roof edge and j extending a min. of 6"onto the field of the roof past the portion of the metal Certalal/e ed Appeal/err which rests on the field 5aSe Sheet membrane). Metal edge detail,Flintlastic STA smooth surfaced APP Modified Bitumen Membrane 25 Drains-APP A strip of Flintlastic APP modified bitumen large enough to extend a min. of 4"beyond the lead flashing edge in all directions (min. 40"x 40")is applied to the base sheet at the drain area. A min. 30" x 30"lead flashing is installed next. Over the primed flashing the field roof membrane is applied in normal fashion.The drain opening should be cut out while the membrane is still warm and the edges sealed. Set the drain cap in place and secure the clamping ring. If two field plies of Flintlastic APP modified bitumen mem- brane are used, the first field ply takes the place of the 40"x 40"flashing ply. Taper • 1 • QNA Insulation :2"c'e to Drain • • fib {�rF Nel r� f Drain Flange Roof Deck Deck i Drain detail,torch applications-part A ` Flintlastic Flashing Collar (approx 40"x 40") Flashing Collar Extended Into and 1 Fully Adhered to ,` �.1 Drain Flange a � Drain detail,torch applications-part B . ;., Lead or -,.... -sc.- - - ..,-- . . /--Copper Flashing .i.--(c." ., t. --‘r,, --- (approx 30 x 30") - .... . . .. . --,-,v.-- --4 • Flashing ..-- Extended Into Drain Flange r . Drain detail,torch applications-part C Strainer Clamping ///1-....-- --- - . Bolts. .:. __.'_:_.'.. ,_.L.____. __ . . . . C\1;."-•: with Integral Gravel Guard -__ --, i ... - -------- ' •4; \\S\ 1 .,.2.7- ',.-- -o- P C ..t" --.O• n H ,.., Drain detail,torch applications-part 0 27 Vent Pipes Position the smooth Flintlastic flashing on a piece of membrane and mark the dimensions of the vents. Cut a hole corresponding to the pipe size so that a snug fit is achieved.The membrane strip must be large enough to extend a min. of 4" beyond the outside edge of the vent pipe flashing flange Lead Sleeve with Primed j Flange Melted ` � Modified ! cP`c Bitumen -- -z---- -..\\ f_ .:;^e..Y'�,�••ara:, Via`; c < 4.z � �c� ,a4� CP '� 47Rool Dech � Vent pipe detail,torch application membrane in all directions. Heat the underside of the membrane strip and press into place. Install the vent pipe collar and secure 3"o.c.around perimeters. Over this the Flintlastic field membrane is applied. Seal the base of the pipe collar with melted modified bitumen. Scuppers „;, - The scupper flange is positioned between the base Mor 11=1 e - e:: 4. ?;!, ply and the Flintlastic field membrane, securely fastened.The field base ply extends a min. of 2”above the cant strip.The parapet wall base ply extends from the top i1 — subsbale . l outside edge of the parapet i 'A over the field base ply to the Carl Slip ; ;, top of the cant strip, securely .a fastened. Install scupper, El 25.>Ply- securely fastened 3"o.c., in Cri--r'f' bead of sealant.The field ply `-`' - or plies(on top of the scupper flange) also extend a min of 2" Scupper detail,torch applications 28