113 Seminole Rd ROOF20-0001 Mod Bit Torch g1AV-7- ROOF NON SHINGLE PERMIT PERMIT NUMBER
gism.s`'`` ROOF20-0001
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ISSUED: 1/14/2020
tilt �rATLANTIC BEACH. FL 32233 EXPIRES: 7/12/2020
MUST CALL INSPECTION PHONE LINE(904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county,and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
JOB ADDRESS; PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
113 SEMINOLE RD ROOF NON SHINGLE MODIFIED BITUMEN TORCH $8000.00
DOWN ROOF
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP: I
170612 0100 SALTAIR SEC 01
COMPANY: ADDRESS: CITY: € STATE: ; ZIP:
JOHN GILMORE ROOFING, 11650 MONTEZ LANE JACKSONVILLE FL 32223
INC.
OWNER: ADDRESS: CITY: STATE: ZIP:
WHITTINGSLOW JOHN D 325 17TH ST ATLANTIC BEACH FL 32233-5822
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
I
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $95.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $47.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.14
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $146.64
Issued Date: 1/14/2020 1 of 2
sciROOF NON SHINGLE PERMITPERMIT NUMBER
CITY OF ATLANTIC BEACHROOF20-0001
V800 SEMINOLE ROAD ISSUED: 1/14/202001.4 _____.,,,,,,,,,,,,
_ �a ATLANTIC BEACH. FL 32233 EXPIRES: 7/12/2020
Issued Date: 1/14/2020 2 of 2
r•S y\,ir;, City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
r� 'i' 800 Seminole Road 1RooF ZO-OOG1j ,r �' AtlanticBeach, Florida 32233-5445 1
Phone(904)247-5826 • Fax(904)247-5845 C� 7 �*�
..01110. y E-mail: building-dept@coab.us Date routed: I /9 /Z 0
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 11 3 S G YI I OLE Department review required Ye No
p y uildin f
Applicant: JOkN el, ( (r(YlOQt ROPi/OC PlanningYZoning
ree Administrator
Project: _O IQ (y Aoo it ( ►vPublic Works
G Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department I First Review: proved. ❑Denied. Not applicable
(Circle one.) Comments:
BUILDIN
PLANNING &ZONING Reviewed by: / Date: /"'/0-(96
TREE ADMIN. Second Review: ❑Approved as revised. Denie . ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. I Denied. Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
i' �'� Building Permit Application Updated10/9/18
-v Ale, OFFICE COPY
W$ City of Atlantic Beach Building Department **ALL INFORMATION
+.— 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
't�' IS REQUIRED.
Phone: (904) 247-5826 Email: Building-Dept@coab.us
Job Address: //3 Sem 4 1 o It I /Q l otAi ht.- omeli Permit Number: d(--)F- Z O O ao i
Legal Description /0 g jD-LS -L9e 54/f *-rf Sec / 14f-637RE#
Valuation of Work(Replacement Cost)$ Ow, 'O Heated/Cooled SF ii-ei 0 Non-Heated/Cooled
• Class of Work: ❑New ❑Addition ❑Alteration VRepair ❑Move ❑Demo ❑Pool ❑Window/Door W O
• Use of existing/proposed structure(s): ❑Commercial Residential U N.
Z
N
lit
• If an existing structure,is a fire sprinkler system installed?: ❑Yes eNo Q .J Z
Q 0 k
• Will tree(s)be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) 1'. 2 t`=
u
Describe in detail the type of work to be performed: �dc <frQ �f � Q �d�v 'Wm d tilj
RC/4ov �yy �/cil R I:? -fid AI 4i',1 4 ,t/ &ni ,i s`t n o 0
/ •� p u
Florida Product Approval# r .4. 7330./ [ /'y77 / for multiple products use product apprdal Erg ZZ
Property Owner Information r / () u- N
Name /tk (r(J4,f�.tf,1f&i Address ;2-Sr l '1 1\ STd En Z
City 1/11V444 h(., 4eir[, ' State �_i— Zip 3z L-"; 3 Phone la (f 710 .5-0� Y O u.. n-
E-Mail ,rdii.(it 4fc / ' 3 8 6 uL f t o—, Q 0 UJ W 5:
Owner or Agent(If gent, Power of Attorney or Agency Letter Required) " - m
W >"'
Contractor Information Lu p w
-� t;j0cnu
Name of Company-,Id/j,L/ a,-4,40"- ? .:. 4,0_.. Qualifying Agent �14v C,"/MQ/l 5. CC W
Add ress4.cp-40 ftv C �h.L City, y t' // State Al/ Zip a..1.2-2ew
Office Phone 1 -q014. V 8D -- 1.0.€7/,‘ Job Site Contact Number /-50i4- L',5'5-i S''$'7
State Certification/Registration# Ceea 5-74 71 E-Mail J 4`,-Ji1 6,1 E 1`'tleb1L1N,9 9ACV,i.ee.4.4
Architect Name& Phone# /I/i1
Engineer's Name&Phone#
Workers Compensation Insurer Je5/ .S-LF OR Exempt❑ Expiration Date /`,2i a /
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition the eqments of this
permit,there may be additional restrictions applicable to this property that may be found in the public r ds�f t;i1�ui es co'Pr+tyg a id;' �i.._,
there may be additional permits required from other governmental entities such as water management dist ch7ttea (kAn— �--•LL.----r-1-
federal
agencies.
OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will ble done in compli � witlinall2020
applicable laws regulating construction and zoning. 1
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERpY l G!�ni IWI Ff 11fi ent
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEYI eF�` FSE -T1':f beach, 7 f_.
RECORNG Y.0 Ili OTICE OF COMMENCEMENT.
kt-- LAI fr;?
(Signat ,: of Owner or Agent)
(Sig
�nature of Contractor)
L/YFeZ----
Signed and sworn to(or affirmed)before me this day of Signed and sworn to(or aff'rmed)before me this( f ' day of
ianwury , .0..1.1^, , b 0 n (Jho! ik i• w S.' . . 2.03 , by • . Et' t WO re,
,,,,,,,,,
,,, `°�6;,,, VIRGINIA ROSALES 6C'gnature o Notary) ,oiPa"PUe VIRGINIA ROSALES �; ature of otary)
'�" •`1 NotaryPublic-State of Florida 1
P.:1—W%i. Notary Public-State 01 Florida •* Al +,_
F.•. iii' • Commission #GG 059564 "sa„ 'r i • Commission #GG 059564
'''',1,17c7117,701,-;',' [0,WIMPNiff-�3`^JPr(ct,2021 , 0in TelW0d1lfr�1419iN95an 27,2021 0
4 Pr•. -. •-i . '111r uced Identification
Y Type o identi 'cation: ' v' Type o !dent 'cation:
Pier c1-- 4"aoF' an , 691
NOTICE OF COMMENCEMENT OFFICE COPY
State of Tax Folio No.
County of OW'4 (
To Whom It May Concern:
The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713
of the Florida Statutes,the following information is stated inOthiis NOTICE OF MENCEMENT//.
Legal Description of property being improved: !/ 3 $eu. i kwie.. f f'�^t fit I@t1G it rt: 3 Z 3 3
ld�ge 54-11-the sets I L.421- 637 r ,/ /r
Address of property being improved: // Sem /4 04- eo e( t 1�a t"t C �7�A.( ' PL 3 Z-2
General description of improvements: /?L= 11Q/14i
Owner: t f O&t`1 (17-1't )( ) Address: 3 Z--5- I//'7 >' °�`� 1.1^1 ftc, 6 &iG6� f Co. 3 2Z)
- s Owner's interest in site of the improvement: s/Ur (•ettrC tw #19
Fee Simple Titleholder(if other than owner):
Name:Aup /
`\1 Contractor: a IiAl a;7/Aft 13A4 Rc Fe/li 'yC
/Iu1 Address: 4 r . i ._ % r :,?C,• / - —
Telephone No./-j 120 -'2Q'< U d J
�� Fax No: y
Surety(if any)
Address: Amount of Bond$
Telephone No: Fax No: Doc#2020002256,OR BK 19057 Page 1777,
Number Pages: 1
Name and address of any person making a loan for the construction of the improvements Recorded 01/06/2020 12:32 PM,
RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL
Name: COUNTY
RECORDING $10.00
Address:
Phone No: Fax No:
Name of person within the State of Florida, other than himself,designated by owner upon whom notices or other documents may
be served: Name:
Address:
Telephone No: Fax No:
In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section
713.06(2)(b), Florida Statues. (Fill in at Owner's option)
Name:
Address:
Telephone No: Fax No:
Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is
specified):
THIS SPACE FOR RECORDER'S USE ONLY OWNER
Signed: / n'/ Date: t A(�
--‘,0
,,,�� „ Before me lis , �, day of 'her >11Q-0in the County o Duval,State
•
oar`�a( VIRGINIA ROSALES Of Florida,has personally appeared ...40140 Gent CO FRIT/NS(,0t.4
. Notary Public-State of Florida Notary Public at Large,State of Florida,County of Duval.
Commission tx GG 059564 f l?- 067-1
�." ii ` , My commission expires: l y7
"4;Rug;,,, My Comm. Expires Jan 27,2021 Personally Known: i or
•mw• Produced Identification: � 0�
OFFICE COPY
• Leather work shoes with synthetic:or:smooth leather soles.
*Leather work gloves That adequately shield the wrist area.Refer also
to the"Safety"section on page 53for information regarding proper
work attire.
Roof Layout
As with most types of roof installations,afttfastic modifl-ij j
installation begins at the low point of the roof with successive rolls
installedso that no laps are against the flow of water.When membrane -
is applied with hot asphalt,where roof slope is 1"per foot or less,,sidelaps
are installed perpendicular to the direction of the roof slope. In,situations
where the roof slope exceeds 1"per foot, rolls are installed wLth the
sidelaps running-parallel to the slope directions.APP modified membranes
can be installed with sidelaps perpendicular to the slope where roof slope is
2"per foot or less(over 2"Install sidelaps parallel to roof slope direction).
Additionally,where roof slope exceeds 1"per foot for SBS modified and
self-adhering membranes or 2" per foot for APP modified "Pack-nailing"
of membrane is required.Refer to the General flecommenda>tions section
of the CertainTeed Commercial ercial.Roof Systems Manualforback-nailing
guidelines.
Endlaps are to be staggered. In multi-ply applications, membrane sidelaps
must also be staggered.
•
F�. •
•
•
Endtap *?
•
2'Sidelap
----'I # --- Endlaps
Staggered
Min.3'Apart
26,14 4 --- 393I8"
4 191t1/16'
Base Flintlastic Flintlastic Meddled
Sheet Interply Sheet Bitumen Cap Sheet
In multi-ply systems,stagger sidelaps from interply and base sheet sidelaps
17
-�? a+-.d'.Endlnp
•
f 2" Stdelap -- --
•
ft .
1
39'3!&
19 Ii&"
e*„. Base Ftintlastic Modified
Sheet Bitumen Gap'Steet
Stagger field sidelaps from base sheet sidelaps
Warning: Flintiastic Modified Bitumen application may require the use'of
hot asphalt and/or an open flame roofing torch.Improper application
practices may cause physical injury to the applicator or damage to the
property. Refer to the current CertainTeed Commercial Roof Systems
Manual for further information
Basic Application: F in't;as i ' APP Modified Eiturriena
Prepare the substrate as described on.page/O..FtWitlastic APP modified
bitumens must be applied using a professional roofer's torch. Use of
hand-held roofing torches is recommended and affords the most control
If multiple burner torching machines are utilized care must be taken to
assure uniform heat application and to avoid overheating of the membrane.
Begin membrane application by
unrolling the roll and aligning the
sidelaps. Rte=rsoll the rail halfway. !-,
Standing on-the unrolled portion to G`
prevent shifting, begin torching the Y }'
exposed polyethylene side of the rs;
rolled portion.Walk forward as
you torch, pushing the heated coil s�
tS:mAuar_
forward and into place with your boot. 2.1J ,.
Position and align the roll
18
Proper torching procedure Involves passing the torch flame in an "L"pattern
across the coiled portion of the roll and up the sidelap area. As subsequent
rolls are installed, heat is applied both to the roll and the exposed laps of
the membrane being overlapped onto.As it is heated,the roll becomes
shiny and the polyethylene film melts away.Adequate heat is confirmed
when a uniform flow of melted bitumen compound flows evenly in a
1/4"-1/2" uniform bead that oozes from the applied membrane's edges.
Be sure to heat the entire roll evenly, not just the lap areas,with extra
concentration at the laps. Once at the end of the roll, re-roll the untorched
half, pulling back to beyond the starting point as much as possible, and
repeat the torching procedure_
j
YS �4
c.S1-5�0 ..„
,7,,.:43/45':• " .4 ININI,,i..544,- T
�. .r r J-.
3"
Sidelap -;%::'` ..
µ
Uniform Bitumen
1 f. 1 tl
Proper torching,in an"L"pattern,assures uniform 1/4'-1/2'compound
and flow at laps and adequate heat across the coil
Trim the lower outside corner of the roll at an angle as shown. Overlap
subsequent rolls 3"at sidelaps (or as specified, min. 3") and 6"at endlaps.
Sidelap lines are generally indicated for the applicators' convenience.
19
r '..,
214Z
4S!„).. •
f F
:L.f`• ?a
.i� .1",.0-4., 44' rG
cY r }yy •
1 XLH aN' vi se �'� j r 4t `\
'' -. -a-0�i. ms's ,,E-. t
Sidelap \\\�
Overlap Flintlastic STA sidelaps a minimum of 3"
Trim the upper outside corner of the subsequent rolls as shown.All trimmed
corners will be covered with the subsequent rolls.
r c�S y `Gt;?f
-
S�
yJ i
i
tri mor/�
cr.4Low,
S'
Endlap cuts are made at an angle as shown
20
It Is critical (especially at the lap areas)to apply adequate heat to both the
membrane being instated and the area of membrane being overlapped
onto. Granuled APP membranes require treatment of the underlying lap
granules by heating and removal or heating and pressing to insure a proper
end lap weld.A warm trowel should be used to check laps for an adequate
seal.Any unbonded areas must be lifted and retorched. Do not attempt to
reseal by torching the top surface of the membrane.
Flashing Details: Flintlastic APP rvioditied Bitumen
Flashing details are accomplished using cut pieces of Flintlastic APP
modified bitumen in combination with appropriate prefabricated flashing
components.The same sidelap and endlap rules apply to flashing
details as to field membrane.
Examples of typical flashing
details are as follows: %Liam,
-
sve
Parapet Wall i&
Noncombustible cant strip must -
be installed at the base of the —,
parapet wall. Field membrane
plies must extend a minimum of `:
2" beyond the top of the cant strip. '
For nailable walls, appropriate
base sheet must also cover
parapet wall and extend to the top
of cant strip. Base sheet extends
over the top of parapet and is
mechanically fastened.
Parapet wall flashing membrane Concrete wall with metal counterflashing
(Flintlastic APP modified bitumen)
not exceeding roll width must — I
extend to the outside edge of the
parapet wall if coping is used, '
or a minimum of 8"above the top
of the cant strip if termination bar
and counterflashing are installed, ++
Parapet
and a minimum of 4"onto the
completed field membrane. <
Wood parapet wall with metal coping
21
Parapet Inside Corners
Base of corner: Make a"V"-shaped cut in the Flintlastic APP modified
bitumen membrane to permit it to conform to the inside corner fold (both
sides of the "V" will neatly overlap when folded into the corner). Use a trowel
to press the heated membrane flaps into place. Top of corner: Cut a notch
part way to permit the top of the membrane to conform to the inside corner
and fold over the top of the parapet. Cap the resulting gap with a strip of
Flintlastic APP modified bitumen.
Fhntfastre Smooth
17 Wide Strip
--., Base Sheet
.•. 1
'
•t
4 9V f ^5 ;1 K f
i r €'*, e ,rsly-. ct
Cant
Slrio— -•,"
Inside corner(parapet)detail-,torch applications-part A
V-Cut in Membrane to
Accommodate Fold
`�
First Flinttastic Smooth
f
Gounlertlash Strap
}
Inside Domer(parapet)detail,torch applications-pert B
22
Second Flintlastm-Smooth
Countedlash Strip
Notch Cut in
Counterllashing to
Accommodate Fold
t r y
t ,
Inside corner(parapet)detail,torch applications-part C
Metal Coping
? I Flintrastic
Membrane
Cotner Pieces
Inside corner(parapet)detail,torch applications-part D
23
Outside Corners and Curbs
At outside corners such as
curbs, the reverse situation
occurs from that of inside
corners.The "V"-shaped
cut goes at the top of the •
membrane strip and the notch
or straight slice at the bottom, " ; ;.d.,:,
since the membrane is folding
the opposite way.
In this case, cap the opening at (7,
°o o
the bottom of the strip which k�extends onto the field of the Outside corner(or curb)detail,
roof a minimum of 4" mineral surfaced torch applications-pert A
Note:Completed field
membrane shall be extended st F+aac,
rA;mr�7
2"above top edge of cant Zsitonterli.o.r.S�:;
and solid attached to cant
strip only.
Outside corner(or curb)detail,
mineral surfaced torch applications-part B
•
dYL.h Ji`f
S ,,,•'t
_-. Crarmi^ath
Stry
Outside corner(or curb)detail,
mineral surfaced torch applications-part C
nn
Metal Edge Detail -Mineral Surfaced Applications
Base sheet must extend over fascia a min. of 2".A min. 9"wide strip of
flashing membrane (Flintlastic APP modified bitumen)should then be
applied to the base sheet,
flush with the roof edge and
extending 9"onto the field of
the roof.
Appropriate edge metal
(min.26 gauge, primed)
must be properly installed
and secured (in two rows, „4'1
spaced every 6"staggered,
fasteners placed every 3"). '
Finally the mineral surfaced V°rl`1iec / f "� : " � t
R'turren •
Flintlastic APP modified Interpw -' :.
bitumen cap sheet is in- • l a „ u
stalled securely over the 4" Ce+tanTe d 'tg'
edge metal face (continuous BaPe S+,eat
from the field of the roof).
Metal edge details,Flintlastic GTA granule
surfaced APP Modified Bitumen Membrane
Metal Edge Detail -Smooth Surfaced Applications
Base sheet must extend over fascia a min. of 2'. Next, the smooth surfaced
Flintlastic APP modified bitumen field membrane is installed, cut flush with
the roof edge.Appropriate
edge metal(min. 26 gauge,
primed) must be properly ;=v,�� 045
Installed and secured. '" •
A min. 10"wide strip of x
Flintlastic APP modified
bitumen smooth surfaced
membrane should then
be applied over the metal •
(flush to the roof edge and j
extending a min. of 6"onto
the field of the roof past
the portion of the metal Certalal/e
ed Appeal/err
which rests on the field 5aSe Sheet
membrane).
Metal edge detail,Flintlastic STA smooth surfaced
APP Modified Bitumen Membrane
25
Drains-APP
A strip of Flintlastic APP modified bitumen large enough to extend a min. of
4"beyond the lead flashing edge in all directions (min. 40"x 40")is applied
to the base sheet at the drain area. A min. 30" x 30"lead flashing is installed
next. Over the primed flashing the field roof membrane is applied in normal
fashion.The drain opening should be cut out while the membrane is still
warm and the edges sealed. Set the drain cap in place and secure the
clamping ring. If two field plies of Flintlastic APP modified bitumen mem-
brane are used, the first field ply takes the place of the 40"x 40"flashing ply.
Taper • 1 • QNA
Insulation :2"c'e
to Drain •
•
fib {�rF
Nel
r�
f Drain
Flange
Roof
Deck
Deck
i
Drain detail,torch applications-part A
` Flintlastic
Flashing Collar
(approx 40"x 40")
Flashing Collar
Extended Into and 1
Fully Adhered to ,` �.1
Drain Flange a �
Drain detail,torch applications-part B
. ;.,
Lead or
-,.... -sc.- - - ..,-- . . /--Copper Flashing
.i.--(c."
., t. --‘r,, --- (approx 30 x 30")
- ....
. . .. .
--,-,v.--
--4
•
Flashing ..--
Extended Into
Drain Flange
r .
Drain detail,torch applications-part C
Strainer
Clamping ///1-....-- --- -
. Bolts. .:. __.'_:_.'.. ,_.L.____. __
. . . .
C\1;."-•: with Integral
Gravel Guard
-__
--, i
...
- -------- ' •4;
\\S\ 1
.,.2.7-
',.-- -o-
P
C ..t"
--.O•
n
H ,..,
Drain detail,torch applications-part 0
27
Vent Pipes
Position the smooth Flintlastic flashing on a piece of membrane and mark
the dimensions of the vents. Cut a hole corresponding to the pipe size so
that a snug fit is achieved.The membrane strip must be large enough to
extend a min. of 4" beyond the outside edge of the vent pipe flashing flange
Lead Sleeve
with Primed
j Flange
Melted ` �
Modified ! cP`c
Bitumen
--
-z----
-..\\
f_ .:;^e..Y'�,�••ara:, Via`;
c
< 4.z �
�c� ,a4� CP
'� 47Rool
Dech �
Vent pipe detail,torch application membrane
in all directions. Heat the underside of the membrane strip and press into
place. Install the vent pipe collar and secure 3"o.c.around perimeters.
Over this the Flintlastic field membrane is applied. Seal the base of the
pipe collar with melted modified bitumen.
Scuppers „;, -
The scupper flange is
positioned between the base Mor 11=1 e - e:: 4. ?;!,
ply and the Flintlastic field
membrane, securely
fastened.The field base ply
extends a min. of 2”above the
cant strip.The parapet wall
base ply extends from the top i1
—
subsbale . l
outside edge of the parapet i 'A
over the field base ply to the Carl Slip ; ;,
top of the cant strip, securely .a
fastened. Install scupper, El 25.>Ply-
securely fastened 3"o.c., in Cri--r'f'
bead of sealant.The field ply `-`' -
or plies(on top of the scupper
flange) also extend a min of 2" Scupper detail,torch applications
28