106 S Saratoga Cir ACC20-0004 Shed „,,,A',�.'„, ACCESSORY PERMIT PERMIT NUMBER
f-1
CITY OF ATLANTIC
ROAD BEACH 2 - 4
” V~ 800 ISSUED:ACC10/15/2020000
0731>r EXPIRES: 7/13/2020
ATLANTIC BEACH. FL 32233
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
ACCESSORY SINGLE OR TWO
106 S SARATOGA CIR FAMILY ACCESSORY SHED 10' x 14' $5709.00
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
171800 0000 ATLANTIC BEACH VILLA#
02
COMPANY: ADDRESS: CITY: STATE: ZIP:
TUFF SHED INC 1116 Blanding Boulevard Orange Park FL 32065
OWNER: ADDRESS: CITY: STATE: ZIP:
MCQUEENEY JAMES JR 106 SARATOGA CIR S ATLANTIC BEACH FL 32233
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
Issued Date: 1/15/2020 1 of 2
,A,l../..„
ACCESSORY PERMIT PERMIT NUMBER
aA 1 CITY OF ATLANTIC BEACH ACC20-0004
800 SEMINOLE ROAD
ISSUED: 1/15/2020
ATLANTIC BEACH. FL 32233 EXPIRES: 7/13/2020
3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration,including sod,is required.
4 PUBLIC WORKS RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site. Cannot raise lot elevation.
`, PUBLIC WORKS DECKING REMOVED INFORMATIONAL
Notes:
All old decking and debris must be removed from job site by Contractor.
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $80.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00
PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00
TOTAL:$249.00
Issued Date: 1/15/2020 2 of 2
City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
800 Seminole Road /`� (�
',-' Atlantic Beach, Florida 32233-5445 I�� �L ~`�OCA—
Date
Phone(904)247-5826 • Fax(904)247-5845 l / � /
_on qr E-mail: building-dept@coab.us routed: � .
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
CL
Property Address: i O(J ,Qr*'a-�O Q. De.artment review required Yes No
_ ( uildinif
Applicant: I lS 442 �R '�t� _ arming &Zonin ,
1 J Tree Administrator
Project: 1 0 y (4 HE--D C____Pubk Wo-'res'- •
ublir; Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: VtApproved. ['Denied. I 'Not applicable
(Circle one.) Comments:
BUILDIN �
PLANNING &ZONING Reviewed by: /y; • Date:1 - 7--(9-6
TREE ADMIN. Second Review: Approved as revised. ['Denied. Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: I 'Approved as revised. Denied. Not applicable
Comments: N.
Reviewed by: Date:
Revised 05/19/2017
p Building Permit Applicatio FFlCE C d ed 12/8/17
` City of Atlantic Beach
`� 800 Seminole Road,Atlantic Beach,FL 32233
/ / Phone:(904)247-5826 Fax:(904)247-5845 /�J�
Job Address: ,1( 6 ,_341.706--,41,I � J AP-441 fic -s ! r 3223• Permit Number: F eaZO _v 0o4
Legal Description 81-13 /7-aS'-„lel E' MtAnrichb,IA4A1(4lt L¢ 6'-K 4. RE# /77Ptt9 O /3
Valuation of Work(Replacement Cost)$ 5701 "--- Heated/Cooled SF Non-Heated/Cooled r
• Class of Work(Circle o' il�,�. Repair = N N
Addition Alteration Move Demo Pool Window/Door B � � O
4
• Use of existing/proposed structure(s)(Circle one): Commercial Residential a. cs M
• If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No I.�1 O 0 cd
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal d 0 0 0
Describe in detail the type of work to be perfoned: LI! E- <X ,
Io1C. 1 ( i.. )ea ec , S o1 dzcc
Oa( o
Florida Product Approval# for multiple products use product approll�l rd-- Z
Property Owner Information V- to
Name: O ilj W
'�p Z3 AldYl �+E2+lQ� Address: 06 S rt1' CO6A ora- S �• n oC 03
City /1-Z ViCi3trlc.:►•► / State t- Zip 3ZZ9.3 Phone •�-40 — ' • W w 0 w
E-Mail I in., Q 4-{/730 Cori/ !_L1_0) wW
Owner or Agent(If A ent,Power of Attorney or Agency Letter Required) 5 CC
Contractor Information CC >
III
Name of Comfpany: TOS ftEC Qualifying Agent:16,77 J Cbe-e/
Address / _ ";•Q ?/-J-7136/9 Cr- S . City i at-- A-14 Stie "(-- Zip—s ZZ33
Office Phone 804-04 r ). "' le 144 Job Site/Contact Number a� i io (`ttoo
State Certification/Registration#(' RC 17.'53(.4 -E-Mail ate. A t•) d)• ['On'1
Architect Name&Phone#
Engineer's Name& Phone#'1d Q U.); it j s 1--)1145,44GyristA ipeolawetir,ev 20ei 0
Workers Compensation
Exempt/Insurer/Lease Employees/Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition itiAl 9.require,rrientslo#th sr�
permit,there may be additional restrictions applicable to this property that may be found in the public r LFi d 'oT this /LT tjl,An i i1
there may be additional permits required from other governmental entities such as water management districts,state agencies,-ori ' Iz'"
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in comp]*Ne wit? a2020
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMB.NT MAY 4^�nt
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPER-17(4F YOU INTEND " }'1 P
"�1"�! �..:�il!= FL
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN A ORNEY BEFORE
- '.CORDING •UR NOTI E OF .46 MENCEMENT. U
; --41111K-A.44111111011111 4
"' (Sig of Owne or Agent) (Signatur f Contra
I'7.42-11 including contractor)
�'S;•ned and sworn to(or affirmed)before me this 03 day of Signed and sworn to(or affirmed)before me this ' day of
Y.E g-, r from 202u ,b J/afiki AeQ��, / April 2019 by Tomm S, rey
'- ''•:'," (Signature of Notary) Si natur .f Nota
w.• '.. E1 LE LEVY
••" Personally Known OR [vf Personally Known OR NOTARY Y PUBLIC
[ ]Produced Identification�j - [ ]Produced Identification STATE(.}F'COLORADO
Type of Identification: c'Iiu UCe-1/322 Type of Identification: ISI/A NIr1TARY In 20174023h9R
MY COMMISSION EXPIRES JUNE 6,2021J
Doc # 2020003455, OR BK 19059 Page 1434 , Number Pages: 1,
Recorded 01/07/2020 11 :51 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY
RECORDING $10. 00
• OFFICE COPYtiNOTICE .
I.::''. `: :.:: (PREPARE INDUPUCATE) . •
PeeNtNo/CC?o ''C1t�d/ Tax Folio Na
r, ' State of '-IAA County of !)Uri
.To whom it may concern: •
The undersigned hereby informs'you that Improvemtnts will be made to certain real property,and In •
accordance with Section 713 of the Florida ems;the following intosmatfart is stated in this NOTICE oF
•
ct�M:
::-.&‘.•••
' •
o►dt perta►DO%improved: 3/ l3 /7-As—a.9E• -
/9?Li-yrlT7 7e4v1I- //log- A.ii it 2. • .
Lor 4 B4 •
- •• tcf eybeinmproved• JO S rAria-,.$ .' .
. being
,47-7.: rr>L17k:e Ftp 3 zzz, •. •, . .
General de• mon of Imps/,J and Sl/eI /o,'/4 • .' . •
• Owner •5Ac\e �C Q.�-o cd\-e-. .' .•• .
Address /Ub '.5612 fa.,.C1: - J jz..a,-*ric •Fc0CN FejtZ3,
/
owneea Interest In site of the Improvement ,. ' •
Fee SimpleTitlholderof other then owner)
Nems'dream ��/r •
• Contractor 1 ki FF•S iter j 3rtc - .'
Address 11'1")'S tiPoRtLissw't '5trtat - men rt. Co : Eloise - •
Phone No.QO4'o2Sa-3144 • Fax No_ •
. Surety fd . •
Adds
Amount of bortd$
Phone No— Fax Ma
•
Name and address of any parson making a loan for the consttuctlon of the Improvements.
Name • • • • .
Address Ifrlg
Phone No. Fax No.
Name of person w l him the State of Florida,other then himself,designated by owner upon wham notices or other.• •:.., I-.'
documents may be served: . - •.
• Name .
.
•
AddressA' ..
Phone No. • . . No, . . •
1
• In addition to himself,owner dem the fdiovi g person to receive a copy of the tlerror's Nottce as provided In
Section 719.06(2)(b),Florida Staines.(FIS in at Owner's option). - -
• Name
•
Address
' Phone No. . Fax No.
Expiration data of Notice of Commencement Opptratlon (1)yeerfmrn the dite of recording unless a •
dlifwent dabs Isape lliw# 1F 1 g .
1
THIS SPACE FOR RECORDER'S use ONLY ',77-,-----4.•
I /.
• ' axis /� n ' m i .
wont tNa.< • �i; yq
J- . 67.gam. Mil. •
_:+per , . .. " •
• Waal hNaaYandeft=alit r •• !Id drrJenemaGadn' �. . *.N
• ars Ma and acclaim ve, ,
• 6134
‘P ;/i/d ))11/4 ‹:D ;•.
atWga,emaa r2 oaunha
•
P,oducaKwi1wardltaaon /�(I[.k /ate •••••••1:4"•. :..f.::::4,-.
.
.i.:._a i.,:;" ...24'./.:',;'.?....,'-;. . '•'x.`,,:,•-,sf..c;,:•:. n;•;••• .•_...d i.4= + r
' '11• :H'_ .- r•ry 's' 2• •�`.• i,•.. :.:?•�.,ttr••1.:- I.- `'•w"i'v-':-.15fi. : .
OFFICE COPY
Tuff Shed, Inc. Customer Name:
State of Florida License#CBC1253645 Address,
r
Product Approval Cover Sheet Permit# 9c C 20-ce)
As required by Florida Statue 553.842 and Florida Administrative Code 9B-72m. Please provide the information an approval numbers for the
building components listed below if they will be utilized on the building or structure. Florida approved products are listed on line at
www.floridabuilding.org or can be obtained from the local product supplier.
All Products listed are per Florida Building Code 6th Edition (2017)
Standard Shed Materials
X Product Type Manufacturer Medel#/ FL product HVHZ
Siding (Panel) LP Corp Panel FL9190.6-R5 YES
Siding (Lap) James L Hardie Lap FL10477.1-R6 YES
Window - Single Croft LLC Series 96 FL15585.1-R5 NO
Window- Sliding Tafco Corp Series 82000 FL207'43.1-R1 NO
Fixed Transom Innovations Inc. Transom FL17667 NO
Roof underlayment Woodland industries 151b Felt FL17206.1-R4 YES
Asphalt Shingles Owens Coming Oakridge _ FL10674.1-R13 NO
Door (Double) Tuff Shed, Inc. Premier- Double Door FL22202.1-R1 _ YES
Door(Single) Tuff Shed, Inc. Premier- Single Door FL22202.2-R1 YES
Door (Double) Tuff Shed, Inc. Sundance- Double Door FL22202.3-R1 _ YES
Door(Single) Tuff Shed, Inc. Sundance- Single Door FL22202.4-R1 YES
Custom Materials Used
Steel Door - Inswing JELD-WEN 6 panel!3068/Inswing FL11136.1-R7 YES
ONINIMONI
Steel Door- Outswing JELD-WEN 6 panel/3068/Outswing FL11136.2-R7 YES
Full lite Door JELD-WEN 3068 FL17454.1 R1 NO
Full lite Door JELD-WEN 6068
9 lite Door JELD-WEN 3068
—
Metal Roofing Thompson Arch Metal Company 5V Crinip FL5218:2-R2 NO
Metal Roofing Thompson Arch Metal Company TIM Rib FL5218.1-R2 NO
—
Flood Vents Flood Solutions LLC Foundation FL17588 NO
�:v.1/2, City of Atlantic Beach rEGE V L APPLICATION NUMBER
jieo Building Department (To be assigned by the Building Department.)
800 Seminole Road JAN p 8 ma +—
j: 41 Atlantic Beach, Florida 32233-544 RCe-�Q �O0 1
Phone(904)247-5826• Fax(904 5845 ii /
J;s {E-mail: building-dept@coab.us Date routed: 7 i0
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: I OCP S ��a�—pa_ Department review required Yes No
f\
�
Applicant: I 11 -� f\LC`i ----Planning&Zonin
Tree Administrator
� X HED
Project: �� � Public 1Nor s
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: [pproved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING ' •
Reviewed biii%' _ late: /—or.-0a
TREE ADMIN.
Second Review: Approved as revised. I (Denied. ['Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. ❑Denied. Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
2C j _tia 10 - 0071-
i, /70 x_t_74— ef zre
/tY
'oet64 -1a- :/: 4(-71
/tekvi Pcpe ,
.= 32 607'
,071ket Lica e g
(
Pfiria_za
oV7
01-AlJfi City of Atlantic Beach APPLICATION NUMBER
�0S ;l� tt Building Department (To be assigned by the Building Department.)
:-. 800 Seminole Road n coo w O c 1-
0:1 /// Atlantic Beach, Florida 32233-5445 I'\ lJl_/ 1
Phone(904)247-5826 Fax(904)247-5845 I / 7 /
Z.O
_0;31/ E-mail: building-dept@coab.us Date routed:
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
( Lr—
Property Address: I 0 6 J .Q!''ck-4-OzQ. Department review required Yes No
( I .iildinq a
Applicant: —11)j -F`--P .11�t"-`I ,---Planning &Zonm
f
I Tree Administrator
1
Project: 1 Q X L S c--IED `� Public Wor s >-,
.-,- Public UtilitiesTh
>
Public Safety
Fire Services
•
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. I 'Denied. I of applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING IA--
Reviewed by: "1 Date: /-/d 74.7
-
TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. Denied. Not applicable
Comments: \,
Reviewed by: Date:
Revised 05/19/2017
-0,:Ly;y City of Atlantic Beach APPLICATION NUMBER
31?ilk Building Department (To be assigned by the Building Department.)
800 Seminole Road (1 (Cao -OocA
.41;
r ) Atlantic Beach, Florida 32233-5445 {"� 1 [� T'
Phone(904)247 5826 Fax(904)247 5845 i / O
_0, r� E-mail: building-dept@coab.us Date routed: ` +/ I/
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
( CL
Property Address: 1062 S -3 C -O � Department review required Yes No
( uildin
Applicant: I l j f �f-\e_C� / annPT ing &Zonin ,
I f__, f Tree Administrator
Project: I V y (4 �`
s -kEt) Public /VorT
-,, Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. ( IDenied. fNot applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING
Reviewed by:, /.9- Date:(—(0-2a2ri
TREE ADMIN. Second Review: A roved as revised.
❑ pp ❑Denied. Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. ['Denied. Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017 .
4. TREE & VEGETATION AFFIDAVIT FOR INTERNAL OFFICE USE ONLY
�s 10 City of Atlantic Beach PERMIT#
.c Community Development Department
800 Seminole Road Atlantic Beach,FL 32233
(P)904-247-5800
/L6 772- IAC/r)0 via Z._.
SITE INFORMATION
ADDRESS /66 S GA c eS /1-7-2-`m-nc 1 f 52233
SUBDIVISION /i71R277jc 1+2// ecGA BLOCK LOT
RE# /7/J0C7- 0000 RESIDENTIAL ❑ COMMERCIAL El OTHER
APPLICANT INFORMATION
NAME 'IV � is 42 C6t,tefi.ey PHONE#
ADDRESS /06 S,a64foJ.4. (,S CELL#
CITY 4714-171-7'c Cg?At,0 STATE ZIP CODE x7X33
EMAIL •�•f j ;MPin h Z `- CI, I s , COQ, ❑ OWNER ❑ LEGAL AUTHORIZED AGENT
I affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation", of
the Municipal Code of Ordinances for the City of Atlantic Beach Florida and/or I have participated in a pre-
application meeting with the Administrator of those regulations. Subsequently, I affirm that no regulated
trees and no regulated vegetation will be damaged,destroyed and/or removed from the above-described
property and/or adjacent properties including right-of-way.
I HEREBY CE• Y THAT ALL INFORMAT % 'ROVIDED IS CORRECT:Signature of Property Owner(s)or Authorized Agent
Pr4 • C_ _111-PDS f C �/ //4z
- l vee/�e T�-
SI 'ATU•E OF APPLICA,/ PRINT OR TYPE NAME DATE
SIGNATURE OF APPLICANT(2) PRINTNOR TYPE NAME DATE
Signed'and sworn beforeme on this 2 day of RI1r2C/wra/ 202° by State of /10ruu
County of �`
Identification verified: 42/ J v �`'f (.7f.tcommission:25FF91432
Troy mu -385-7019
Oath Sworn: ❑ Yes ❑ No •at.c 44•;•• - -• •
Notary Signature • 4
My Commission expires 1 45'c a 0
04 TREE AND VEGETATION AFFIDAVIT 03.01.2018
r '
• O
�•i
I
7
NOTES:
1. BUILDING CODE: FLORIDA BUILDING CODE, 6th EDITION (2017)
BUILDINGS ARE NOT FOR HIGH -VELOCITY HURRICANE ZONES
(HVHZ)
2. DESIGN LOADING:
WIND SPEED: V„ It = 155
Vasd = 120
EXPOSURE: C
ROOF LIVE LOAD: 20 PSF
ROOF DEAD LOAD: 10 PSF
FLOOR LIVE LOAD: MIN. 50 PSF (SEE NOTE 5, DETAIL 1, SHEET 3)
RISK CATEGORY: I
COMPONENT AND CLADDING: ROOF: 29 PSF (ZONE 1)
WIND PRESSURE (psl] (ASD VALUES) 50 PSF (ZONE 2)
(BASED ON 10 SQ FT) 74 PSF (ZONE 3)
WALL: 34 PSF (ZONE 4)
42 PSF (ZONE 5)
FLORIDA BUILDING APPROVAL NUMBERS --
1. WINDOWS BY TAFCO CORP- FLORIDA BUILDING APPROVAL
#FL20743.1.
2. WINDOWS BY SILVER LINE BUILDING PRODUCTS CORP - FLORIDA
BUILDING APPROVAL FL14911.5.
3. LP SMARTSIDE SIDING - FLORIDA BUILDING APPROVAL #FL9190.6.
4. ROOF UNDERLAYMENT BY WOODLAND INDUSTRIES INC. -
FLORIDA BUILDING APPROVAL #FL17206.1.
5. ROOF UNDERLAYMENT BY GAF - FLORIDA PRODUCT APPROVAL
#FL18686.1
6. SHINGLES BY OWENS CORNING - FLORIDA BUILDING APPROVAL
#F L 10674.1.
7. SHINGLES BY GAF - FLORIDA PRODUCT APPROVAL #FL10124.1
8. INNOVATIONS MANUFACTURING, INC. TRANSOM WINDOWS -
FLORIDA BUILDING APPROVAL #FL17667.1.
9. FLOOD SOLUTIONS, LLC FLOOD VENTS (IF REQ'D)-
FLORIDA BUILDING APPROVAL #FL17588.1.
10. OX PAPERBOARD MICHIGAN, LLC THERMO-PLY SHEATHING -
FLORIDA BUILDING APPROVAL #FL16391.1.
11. TUFF SHED, INC DOORS - FLORIDA BUILDING APPROVAL
#FL22202.1, #FL22202.2, #FL22202.3, #FL22202.4
HEADER NAILING:
HEADER TO STUD - 4-16d END NAIL DOUBLED HEADER
- 16d @ 16" STAGGERED FACE NAIL
NAILING:
REFER TO SHEET 2 FOR WALL AND ROOF SHEATHING NAILING.
MAX WALL HEIGHT FOR EACH SHED:
SR600 - 5'-8 1/4" (68 1/4")
TR700 - 6-8 1/4" (80 1/4")
PR - 6-8 1/4" (80 1/4")
Order #.
TUFF SHED Customer: _
Storage Buildings & Garages Site Address:
nm
UFF SHED, MFG. FACILITIES
Building Size:WIDTH-LENGTH-HEIGHT - SQ. Fr.ARE
UNINHABITED UTILITY SHED
SR600,
OVERHANG OPTIONS
CD
W
J
UP TO 12' WIDE x UP TO 24' LONG
TR700, PR
REFER TO THE TRUSS DESIGN FOR
LUMBER SIZE, TRUSS SPACING
AND PLATE SIZE
COLLAR TIE REQUIRED ONLY AT
12' WIDE SHEDS, SEE TRUSS CALCULATIONS
12
4
SEE SHEET 3 FOR STEEL FLOOR WITH
ANCHOR DETAIL OR FOUNDATION DETAIL
UP TO 12' WIDE
0 BUILDING SECTION
SCALE: N.T.S.
DOUBT E TOP PLATE
CRIPPLES (IF REQ.)
HEADERS FOR
OPENINGS UP TO 4'-0"
USE (2) 2x4 SPF #2
2x4 WINDOW SILL
FLOOR DECKING
BASE PLATE
FOR WINDOW OPENINGS UP TO 4'-0"
3 WINDOW HEADER DETAIL
FOR SIDE WALLS
SCALE: N.T.S.
P.O. #
THESE DRAWINGS AND THE
I
N 7835
DESIGN ARE THE PROPERTY
RICHARD J. WILLS, P.E.
Drawn By: PK
OF TUFF SHED, INC. THESE
DRAWINGS ARE FOR A
1777 S. HARRISON STREET
Date: 3/12/19
BUILDING TO BE SUPPLIED
AND BUILT BY TUFF SHED.
DENVER, COLORADO 80210
Checked By:
ANY OTHER USE IS
FORBIDDEN BY BOTH TUFF
Date:
o R i o P•
SHED AND THE ENGINEER OF
IRECORD
Scale: N.T.S.
RAFTER
FLORIDA APPROVED OWENS
CORNING OAKRIDGE 30 YEAR
SHINGLES - FL10674-R10
SEE THE TRUSS SIMPSON H2.5A PL
CONNECTION INSIDE AT EACH F
DETAIL - DETAIL 2 WALL TOP I
WALL FRAMING TO BE
2x4 SPF #2 OR BETTER
@ 16" O.C.
IF BUILDING IS LOCATED
IN A FLOOD ZONE THEN
FLOOD VENTS AND PRESSURE
TREATED STUDS ARE REQUIRED -
ONE SQ INCH VENT
FOR EVERY ONE SQ FT
OF BUILDING
"OUBLE TOP PLATE
RIPPLES (IF REQ.)
TOE NAIL WITH (3)
6d NAILS, (2) ONE
;IDE, (1) OTHER
;IDE
OTRUSS TO WALL
CONNECTION DETAIL
EADERS FOR
OPENINGS UP TO 4'-0"
USE (2) 2x4 SPF #2
DPENINGS 4'-1" TO 6'-0"
USE (2) 2x6 SPF #2
DPENINGS 6-1" TO 8'-0"
USE (2) 2x8 SPF12
NG STUD
RIMMER 1
1-1
FOR OPENINGS UP
3B DOOR H
FOR SID
SCALE: N,T.S,
TUFF SHED, INC.
ENGINEERING DEPARTMENT
`��
'M
:•
I
N 7835
RICHARD J. WILLS, P.E.
= e
1777 S. HARRISON STREET
o's
DENVER, COLORADO 80210
��o:_•• sTn,TE of
(303) 753-8833 EXT. 96315
iii �C '•�
SSS,,:.
o R i o P•
� .
L
SCALE: N.T.S.
KING STUD
CRIPPLE STUD
HEADERS FOR:
TRIMMER STUD
OPENINGS UP TO 6'-0" USE (2) 2x4 SPF #2
OPENINGS 6-1" TO 8'-0" USE (2) 2X6 SPF #2
REFER TO THE DOOR DETAIL (SHEET 2) FOR
THE DOOR DESIGN
4 HEADER DETAIL FOR
END WALLS
SCALE: N.T.S.
TITLE DRAWING NO.
BUILDING SECTIONS FL -PR -SR -TR -01
HEADER FRAMING DETAILS REV. LEVEL 01
FBC, 6th EDITION (2017) SHEET 1
155C
PAGE 1 OF 4
TUFF S}{ED
Storage Buildings & Garages
Tht UFF SHED, MFG. FACILITIES
Order #.
Customer:
Site Address:
P.O. #
Drawn By: PK
Date: 3/12/19
Checked By:
—
Building Size.WIDTH-LENGTH -HEIGHT -SQ. FI. AREA Date:
Scale: N.T.S.
3/8 SMART SIDE NAILING REQUIREMENTS
USE THESE NAILING TABLES FOR THE SR600, TR700 AND PR DRAWINGS
SIDE WALL EDGE NAILING REQUIREMENTS
MARK MAX.
WALLS END SIDE COMB. MIN TOTAL
BEING WALL WALL OPENING COMBINED
USED WIDTH LENGTH EDGE NAILING (NOTE 2) SHEAR WALL
NU UFhNINGS ALONG THE WALL
EDGE NAILING
6'
6'
6'-18'
8d NAILS @ 6" O.C.
0'
6'-18'
8'
8'-24'
8d NAILS @ 6" O.C.
0'
8'-24'
10'
10'-24'
8d NAILS @ 6" O.C.
0'
10'-24'
12'
12'-24'
8d NAILS @ 6" O.C.
0'
12'-24'
■ MIN 2'-0" RTN WALLS ON EACH END OF WALL- ■ MIN 2'-0" WALL SEGMENT
ROOF SHEATHING (7/16" OSB)
WIDTH LENGTH FIELD NAILING
EDGE NAILING
6'
6'-18'
8d NAILS @ 12" O.0
8d NAILS @ 4" O.C.
8'
8'-24'
8d NAILS @ 12" O.0
8d NAILS @ 4" O.C.
10'
10'-24'
8d NAILS @ 12" O.0
8d NAILS @ 4" O.C.
12'
12'-24'
8d NAILS @ 12" O.0
8d NAILS @ 4" O.C.
NOTES:
1. USE 8d COMMON OR GALVANIZED BOX NAILS.
TABLE NOTES:
1. NAILING IS FOR 3J8" SMARTSIDE PANEL OR 3/8" SMARTSIDE
WITH FOIL BACKER.
2. NO SINGLE OPENING GREATER THAN 8'-0"
3. * 6' WIDE X 6'-9' LENGTH BUILDINGS ARE BASED ON 3 -SIDED
DIAPHRAGM. THE END WALL OPPOSITE OF THE OPENING MUST
BE FULLY SHEATHED, IN THE 3 -SIDED DIAPHRAGM CASES. THE
END WALL WITH THE OPENING DOES NOT HAVE A MIN. RETURN
WALL ON EACH SIDE OF THE OPENING.
4. USE COMMON OR GALVANIZED BOX NAILS.
5. FIELD NAILING FOR 3/8" SMARTSIDE: 8d @ 12" O.C.
6. ON THESE BUILDINGS 6'X 10'-18' THE T DOOR IN THE END WALL
WILL NEED TO BE OFF SET. THERE WILL BE A 2' PANEL ON ONE
SIDE AND A 1' PANEL ON THE OTHER SIDE OF THE DOOR.
7. (BS) - DESIGNATES WALLS THAT NEED TO BE SHEATH ON
BOTH SIDES. A
THESE DRAWINGS AND THE
DESIGN ARE THE PROPERTY
OF TUFF SHED, INC. THESE
DRAWINGS ARE FOR A
BUILDING TO BE SUPPLIED
AND BUILT BY TUFF SHED.
ANY OTHER USE IS
FORBIDDEN BY BOTH TUFF
SHED AND THE ENGINEER OF
RECORD.
6'
END WALL EDGE NAILING REQUIREMENTS
MARK
SEE NOTE 3
6'
10'
8d NAILS @ 3" O.C. (BS)
3'
WALLS
BEING
END
WALL
SIDE
WALL
8d NAILS 4" O.C.
MAX.
MIN TOTAL
USED
WIDTH LENGTH
EDGE NAILING
COMB.
OPENING
COMBINED
SHEAR WALL
8'
NO OPENINGS
ALONG THE WALL
3'
5'
8'
' 6'
6'
8d NAILS @ 3" O.C.
SEE NOTE 3
8'
* 6'
8'-9'
8d NAILS @ 3" O.C. (BS)
SEE NOTE 3
8'
6'
10'-14'
8d NAILS @ 3" O.C.
0'
6'
10'
6
16'-18'
8d NAILS @ 4" O.C. (BS)
0.
6'
8d NAILS @ 4" O.C.
8'
8'-12'
8d NAILS @ 6" O.C.
U
8'
3'
8'
14'-18'
8d NAILS @ 4" O.C.
0'
8'
7'
8'
20'-22'
8d NAILS @ 3" O.C.
0'
8'
10'
8'
24'
8d NAILS @ 4" O.C. (BS)
0'
8'
18'-24'
10'
10'-14'
8d NAILS @ 6" O.C.
0'
10'
18d NAILS 3" O.C.
10'
16'-20'
8d NAILS @ 4" O.C.
0'
10'
6'
10'
22'-24'
8d NAILS @ 3" O.C.
0'
10'
8'
12'
12'-16'
8d NAILS @ 6" O.C.
0'
12'
12'
12'
18'-24'
8d NAILS @ 4" O.C.
0'
12'
■ MIN 2'-0"
RTN WALLS ON
EACH END OF WALL- ■MIN 9•-n" Wei i cFrrenr-tiT
6'
8d NAILS @ 6" O.C.
3'
SEE NOTE 3
6'
10'
8d NAILS @ 3" O.C. (BS)
3'
2' (RE: NOTE 6
8'
8'-10'
8d NAILS 4" O.C.
3'
5'
8'
12'-14'
8d NAILS @ 3" O.C.
3'
5'
8'
16'-24'
8d NAILS @ 3" O.C. (BS)
3'
5'
8'
1 8'
8d NAILS @ 4" O.C.
4'
4'
8'
10'
8d NAILS @ 3" O.C.
4'
4'
8'
12'-22'
8d NAILS @ 3" O.C. (BS)
41
4'
10'
10'
8d NAILS 6" O.C.
3'
7'
10'
12'-14'
8d NAILS @ 4" O.C.
3'
7'
10'
1 16'-18'
8d NAILS @ 3" O.C.
3'
7'
10'
20'-24'
8d NAILS 4" O.C. BS
3'
7'
10'
10-12'
8d NAILS @ 4" O.C.
4'
6'
10'
14'-16'
8d NAILS P3" O.C.
4'
6'
10'
18'-24'
18d NAILS 4" O.C. BS
4'
6'
10'
10'
18d NAILS 3" O.C.
6'
10'
12'-22'
18d NAILS @ 3" O.C. (BS)
6'
4'
12'
12'-16'
8d NAILS @ 4" O.C.
4'
8'
12'18'-20'
8d NAIL 3'
4'
8'
12'
22'-24'
8d NAILS a 3" O.C.(BLS)_4'
8'
12'
12'6'
6'
14'-16'
6'
6'
gi
18'-24'
8d NAILS @ 4" O.C. (BS)
6'
6'
12'-20'
8d NAILS 3" O.C. BS
8'
4'
11 I I I JfJ
TUFF SHED, INC.
ENGINEERING DEPARTMENT
0. 76835
RICHARD J. WILLS, P.E. a
1777 S. HARRISON STREET —
DENVER, COLORADO 80210 srTE of
(303) 753-8833 EXT. 96315 �i �,c • c< R p
�j��/dddd►II111\1�1� �
TITLE
DOOR DETAILS
NAILING REQUIREMENTS
FBC, 6th EDITION (2017)
155C
DRAWING NO.
FL -PR -SR -TR -01
REV. LEVEL 01
SHEET n
PAGE 2 OF 4
#12-14 X 3" HEX HEAD—
SELF-DRILLING SCREWS
3/4" APA OR TECO RATED—
T&G FLOOR DECKING.
2X6 STEEL JOISTS
@ 24" OC
#10 X 3/4" PAN
HEAD SELF -DRILLING
SCREWS (2 PER TAB)
VENT HOLES @ 24" OC. —�
OPTIONAL LEVELING BLOCKS
2X6 STEEL TRACK EACH END
BASE PLATE SCREW SPACING
WIDTH SPACING
6'-12' 8" O.C.
OSTEEL SHED BASE DETAIL
SCALE: N.T.S.
SIDING
TRIM
3/8" CARRIAGE
BOLT (GRADE 2)
OT17SWB
-OR-
OT24SWB
1/2" HILTI KWIK BOLT TZ
STAINLESS STEEL 304
EMBEDMENT DEPTH = 2 1/4"
MIN. EDGE DISTANCE = 6"
ANCHOR SPACING: RE: KWIK
BOLT ANCHORS TABLE, SHEET 3
1. STEEL SHED FOUNDATION:
600T125-054 - 16 GAUGE ST
600S137-054 - 16 GAUGE S
@ 24" O.C.
(SUPPLIER: ALLIED STUDC
�� �- STUD
S-rEEL SI
BASE
4" CONCRETE
PAD (MIN)
OSIDEWALL BRACKET DETAI
SCALE: N.T.S.
KWIK BOLT ANCHORS
(INTO CONCRETE
E: DETAIL 3 SHEET 3
3/8" NYLON
EEL TRACKS G140 ZINC COATED
QTY
LOCK MUT
TEEL JOISTS G140 ZINC COATED
•
z B/iSEPLATE
8
114
0 (JOIST: 600S137-054 /TRACK.-
6" I
O
600T125-054) ICC ER -4943P.
i
2.
3/4" APA OR TECO RATED T ONGUE AND GROOVE FLOOR
10
10'
DECKING. 24" MAX PANEL SPAN. STAGGER PANEL LAYOUT.
6
3.
FASTEN FLOOR DECKING T O JOIST & TRACKS USING
8
12'
#8 x 1-5/8" ZINC PLATED SC REWS @ 12" O.C.
6
12'
NO BLOCKING REQUIRED. ALL EDGES SHALL LIE ON FLOOR
8
JOISTS. STAGGER PANEL LAYOUT PER APA CONDITION 1.
4.
FASTEN SOLE PLATE THRO UGH FLOOR DECKING INTO JOISTS
OR TRACKS WITH #12-14 X 3" GALVANIZED SELF -DRILLING
i
SCREWS. REFERENCE SPA CING CHART.
i
5.
ALLOWABLE FLOOR LIVE L CAD: 75 PSF FOR STEEL JOISTS
CONTINUOUSLY SUPPORT ED. 50 PSF FOR JOISTS ON BLOCKS
AS SHOWN.
6.
USE OPTIONAL CONCRETE BLOCKS AS REQUIRED TO LEVEL
BUILDING:
SUGGESTED SIZES: 2" x 8" x 16", 4" x 8" x 16", OR 8" x 8" x 16".
BLOCKS UNDER JOISTS SP ACED @ 8'-0" O.C. MAXIMUM.
BLOCKS UNDER TRACK SP ACED @ 4'-0" O.C. MAXIMUM.
S-rEEL SI
BASE
4" CONCRETE
PAD (MIN)
OSIDEWALL BRACKET DETAI
SCALE: N.T.S.
KWIK BOLT ANCHORS
(INTO CONCRETE
E: DETAIL 3 SHEET 3
3/8" NYLON
LENGTH
QTY
LOCK MUT
6'-10'
6
z B/iSEPLATE
12'-18'
8
114
r- FLOOR PLY
6" I
O
16'-20'
S-rEEL SI
BASE
4" CONCRETE
PAD (MIN)
OSIDEWALL BRACKET DETAI
SCALE: N.T.S.
KWIK BOLT ANCHORS
(INTO CONCRETE
E: DETAIL 3 SHEET 3
WIDTH
LENGTH
QTY
6'
6'-10'
6
6'
12'-18'
8
8'
8'-14'
6
8'
16'-20'
8
8'
22'-24'
10
10'
10'-16'
6
10'
18'-24'
8
12'
12'-18'
6
12'
20'-24'
8
NOTES:
1. ANCHORS TO BE KWIK BOLT TZ, 304 SS
2. PROVIDE (1) ANCHOR AT EA. CORNER
OF THE BUILDING. THE REMAINING
ANCHORS EQUALLY SPACED ALONG THE
LENGTH OF THE BUILDING. (1/2 THE
REMAINING ANCHORS ON EA. LENGTH
SIDE EQUALLY SPACED). I MI
LJ CONCRETE FOUNDA
J SCALE: N.T.S.
-V
Order #.
Customer:
Site Address:
TRIM
2X4X2'
# OF ANCHORS
SIDING
BLOCK
4 ANCHORS
8'
8'-24'
4 ANCHORS
ATTACH BRACKET TO
10'-24'
6 ANCHORS
STUD THRU HOLE IN
12'-24'
6 ANCHORS
ANCHOR PLATE WITH
z
3/8"0 x 4" CARRIAGE
BOLT AND LOCKNUT
`rCORNER
STUD
AUGER ANCHOR COMPONENTS BY OLIVER TECHNOLOGIES
• PART NUMBERS:
OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER
OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS
REPORT NO. LO-FJ90129-A
-O R-
OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS
REPORT NO. LO-FJ90129-B
• WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS
WITH THE MAXIMUM LOAD OF 5,080 LBS
STUD
0
U)
STUD
} I END WALL
AUGER ANCHORS
Order #.
Customer:
Site Address:
WIDTH
I LENGTH
# OF ANCHORS
6'
6'-18'
4 ANCHORS
8'
8'-24'
4 ANCHORS
10'
10'-24'
6 ANCHORS
12'
12'-24'
6 ANCHORS
SIDING 4-ANUMUK6 HKOVIDE (1) AT EA.
CORNER OF THE BUILDING.
6 -ANCHORS PROVIDE (1) AT EA.
TRIM CORNERS OF THE BUILDING AND (1) AT
THE CENTER OF EA. SIDE WALL.
ANCHOR BRACKET
TO BE FLUSH WITH
®AUGER ANCHOR DETAIL EDGE of TRIM
SCALE: N.T.S.
UNHEATED SPACE
ANCHOR BOLT &
P.T. SILL PLATE
PER NOTES BELOW
#4 CONTINUOUS
L 1 3/4' TOP & BOTTOM
U >- FINISH CONCRETE FLOOR
ch GRADE
z- - --- �r
-a ,- -- a- .d.
ILLIL 3" CLR.
v TYP~
Cl)
TUFF SHED
Storage Buildings & Garages
TUFF SHED, MFG. FACILITIES
Order #.
Customer:
Site Address:
_
P.O. #
—
Drawn By: PK
_
Date: 3/12/19
—
Checked By:
�+
Building Size:WIDTH-LENGTH -HEIGHT -SO. F1'.
AREA
Date:
Scale: N.T.S.
THESE DRAWINGS AND THE
DESIGN ARE THE PROPERTY
OF TUFF SHED, INC. THESE
DRAWINGS ARE FOR A
BUILDING TO BE SUPPLIED
AND BUILT BY TUFF SHED.
ANY OTHER USE IS
FORBIDDEN BY BOTH TUFF
SHED AND THE ENGINEER OF
RECORD
"' CSLAB
REINFORCEMENT
PER NOTES BELOW
THICKENED SLAB
TUFF SHED, INC.
ENGINEERING DEPARTMENT
RICHARD J. WILLS, P.E.
1777 S. HARRISON STREET
_
DENVER, COLORADO 80210
-o'
(303) 753-8833 EXT. 96315
9
k x../ Vv'
,76835 °
TATV OF
//111111 I111���
CONTINUOUS FOOTING NOTES
1. TOP OF SLAB TO BE 6" MIN. ABOVE GRADE. SLAB REINFORCEMENT SHALL
BE WWF 6X6 W1.4xW1.4 . LOCATE AT MID -DEPTH OF SLAB.
-OR-
SLAB REINFORCEMENT SHALL BE FIBERMESH 150 OR BLENDED
FIBERMESH150, FIBERMESH SHOULD BE DISPERSED UNIFORMLY
THROUGH CONCRETE W/ MIN. 1 POUND PER CUBIC YARD OF CONCRETE.
2. ALL FOOTING FORMS SHALL BE INSPECTED FOR SIZE AND REINFORCING
BEFORE POURING CONCRETE.
3. FOOTINGS SHALL BEAR ON UNDISTURBED NATURAL, COMPETENT SOIL,
OR PROPERLY COMPACTED STRUCTURAL FILL. ALLOWABLE SOIL
BEARING PRESSURE IS 1000 PSF AT 12" BELOW GRADE.
4. CONCRETE: MINIMUM 28 DAY COMPRESSIVE STRENGTH, fc=2500 PSI.
5. REINFORCING STEEL: A615, GRADE 40 OR GRADE 60. ALL REINFORCING
STEEL SHOWN TO BE CONTINUOUS MAY BE LAPPED A MINIMUM OF 38 BAR
DIAMETERS OR 24" MINIMUM, WHICHEVER IS LARGER.
6. SEISMIC DESIGN CATEGORY: A
A. ATTACH PRESSURE TREATED SOLE PLATE TO THE FOOTING USING
1/2" DIA X 8" LONG SIMPSON TITEN HD ANCHOR WITH WASHERS,
B. EXPANSION BOLTS SHALL BE EMBEDDED AT LEAST 5" INTO THE
CONCRETE AND SHALL BE SPACED NOT MORE THAN V OC.
C. THERE SHALL BE A MINIMUM OF 2 BOLTS PER SOLE PLATE PIECE
WITH 1 BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 7 BOLT
DIAMETERS FROM EACH END OF EACH PIECE.
TITLE DRAWING NO.
DETAILS I
FL -PR -SR -TR -01
I REV. LEVEL 01 1
((� FBC, 6th EDITION (2017) SHEET 3
\ 155C
PAGE 3 OF 4
3X4 20 PLATES
T-0" I 1 EACH SIDE
3:1 71811
_zz12
4
7
to
0 6'-0"
LO
N
3X4 20 PLATES
LO 1 EACH SIDE
4'_2
12
Q 4
Co
00
L0
N
DESIGN LOADS:
TOP CHORD LIVE LOAD = 20 PSF
TOP CHORD DEAD LOAD = 10 PSF
COLLAR TIE DEAD LOAD = 5 PSF
NOTES:
FBC, 6th EDITION (2017)
ANSI/TPI 1-2007
TRUSSES TO BE SPACED @ 24" OC
MATERIAL TO BE 2X4 SPRUCE PINE FIR GRADE #2 OR BETTER
PLATES ARE TO BE PRESSED IN THE WOOD PER TPI.
REP MEMBER INCREASE: YES
LUMBER D.O.L.: 1.25
00
Cl)
00
LO
N
N
r
� 5'-0" /
18.0°
00 10'-0"
0
N
— 3X4 20 GA PLATE
1 EACH SIDE
S`3 1/16, 6' SPAN
REACTIONS:
12 MAX. VERTICAL: 180 LBS.
�4 MAX. UPLIFT: -160 LBS.
3X4 20 GA PLATES
6'-0" 1 EACH SIDE
6,3 1116,
12
Q 4
o'
a 3X6 20 GA
PLATES
1 EACH SIDE
e
12'-0"
NOTE:
TRUSS MAY BE USED ON BUILDING LENGTHS
UP TO 12FT UNLESS CEILING JOIST OR OTHER
TENSION TIE IS PROVIDED.
10' SPAN
REACTIONS:
MAX. VERTICAL: 300 LBS.
MAX. UPLIFT: -250 LBS.
NOTE:
TRUSS MAY BE USED ON BUILDING LENGTHS
UP TO 20FT UNLESS CEILING JOIST OR OTHER
TENSION TIE IS PROVIDED.
MAXIMUM DEFLECTION (12 FT. SPAN)
VERT LL: 0.06 in.
VERT TL: 0.08 in.
WIND:
ASCE 7-10,155 mph, Exposure C, D.O.L.=1.60
PLATES ARE MANUFACTURED BY EAGLE METAL PRODUCTS, ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING THIS TRUSS ARE TO DO SO
ICC -ES #ESR -1082. ACCORDANCE TO THE RECOMMENDATIONS OF THE LATEST VERSION OF THE BCSI.
TUFF S
Storage Buildings & Garages
TUFF SHED, MFG. FACILITIES
8524 EAST COLONIAL DRIVE
ORLANDO, FL 32817
(888)788 -TUFF
3101-520
Order #. _
Customer:
Site Address:
P.O. #
THESE DRAWINGS AND THE
DESIGN ARE THE PROPERTY
OF TUFF SHED, INC. THESE
DRAWINGS ARE FOR A
BUILDING TO BE SUPPLIED
AND BUILT BY TUFF SHED.Checked
ANY OTHER USE IS
FORBIDDEN BY BOTH TUFF
SHED AND THE ENGINEER OF
RECORD
Drawn By: PK
Date: 3/12/19
By:
t —
Building SIZe:WIDTH-LENGTH- HEIGHT -SQ. FT. AREA
Date:
Scale: N.T.S.
TUFF SHED, INC.
ENGINEERING DEPARTMENT
RICHARD J. WILLS, P.E.
1777 S. HARRISON STREET
DENVER, COLORADO 80210
(303) 753-8833 EXT. 96315
No.7 5
� '0 TA E OF
NAL ��,
11111/11 it n 1i11\��\\
8' SPAN
REACTIONS:
MAX. VERTICAL: 240 LBS.
MAX. UPLIFT: -195 LBS.
NOTE:
TRUSS MAY BE USED ON BUILDING LENGTHS
UP TO 14FT UNLESS CEILING JOIST OR OTHER
TENSION TIE IS PROVIDED.
12' SPAN
REACTIONS:
MAX. VERTICAL: 390 LBS.
MAX. UPLIFT: -285 LBS.
NOTE:
TRUSS MAY BE USED ON BUILDING LENGTHS
UP TO 24FT UNLESS CEILING JOIST OR OTHER
TENSION TIE IS PROVIDED.
TITLE DRAWING NO.
TRUSS DETAILS FL -PR -SR -TR -01
REV. LEVEL 01
FBC, 6th EDITION (2017) SHEET 4
155C
PAGE 4 OF 4